首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
Abstract

High-throughput methods are now routinely used to rapidly screen chemicals for potential hazard. However, hazard-based decision-making excludes important exposure considerations resulting in an incomplete estimation of chemical safety. Models to estimate exposure exist, but are generally unsuited to keep up with high-throughput demands. The High-Throughput Exposure Assessment Tool (HEAT) is designed to efficiently predict near-field exposure to consumers and workers via inhalation, oral and dermal routes. HEAT is based on well-known modeling algorithms and provides default model parameters to support reasonably conservative exposure estimates. Underlying chemical-specific data are uploaded or entered by the end user. HEAT’s main strength is the flexible tiered screening functionality, which enables exposure estimates for single or multiple chemicals simultaneously. Hypothetical case examples highlighting the application of HEAT to more complex exposure estimates for alternative and aggregate assessments are provided.  相似文献   

2.
In Hungary it is typical that 10/04 kV transformer stations are being installed in multistory residential and office buildings. Magnetic fields (MFs) up to several tens of microT have been measured in apartments close to transformers. The aim of the present study was to provide systematic assessment of MF exposure of residents living above transformer stations. Out of 41 addresses provided by the electricity supplier, current load of 21 transformers and MF in 21 apartments was measured. Spot MFs at 1 m height and time weighted average 24 h MF exposure at bed height was measured. All-day personal MF exposure was measured at waist and HOME exposure was calculated. BED exposure was measured at bed height. Participants kept a time-activity diary. The time-weighted average 24 h MF exposure (3.03 microT) exceeded the usual residential exposure (<0.2 microT). The mean HOME and BED personal exposure above transformers was 0.825 and 1.033 microT, respectively. Our study provides exposure assessment of a cohort with a wider exposure range, compared to power-line epidemiological studies.  相似文献   

3.
This study investigates the individual magnetic field exposures at 16 2/3 and 50 Hz of 1952 people, selected from the Bavarian population. Personal flux density meters ("Field Watcher FW2A") were worn by the participants for 24 h. Every second, the flux density was recorded for both frequencies and for the three spatial axes (dynamic range per axis: several nT up to 100 microT at 50 Hz, 150 microT at 16 2/3 Hz). For 50 Hz fields, the mean of the 1,952 individual means was 0.101 microT and that of the individual medians was 0.047 microT. High level exposures occurred mainly during working hours. Only 2.4% of the subjects showed individual medians higher than 0.2 microT. About 53% of all volunteers were working on the day of recording. Levels for craftsmen (n = 148; mean individual mean: 0.166 microT) were generally higher than those for office workers (n = 624; mean individual mean: 0.107 microT). Flux densities exceeding 100 microT at 50 Hz were measured in 31 persons. The total time with such extreme exposures amounts to nearly 21 min, less than 0.001% of the total time for all measurements (5.3 years). To our knowledge, this is the first exposure study where 16 2/3 Hz magnetic fields (caused by electrified railways) have additionally been monitored over 24 h. For persons living next to railway lines, the mean individual mean (0.156 microT) and mean individual median (0.102 microT) were calculated. Over all, the mean exposures are only 0.1% of the magnetic flux density limit for 50 Hz (100 microT) and about 0.05% of the limit (300 microT) for 16 2/3 Hz recommended by the International Commission on Non-Ionizing Radiation Protection.  相似文献   

4.
Personal RF exposimetry has been in the focus of the bioelectromagnetics community in the last few years. With a few exceptions, exposimetry studies focused on adults, because measuring the exposure of children, one of the most important target groups, introduces many complications.The main feature of our study is to select teachers and kindergarten caretakers as volunteers. They are expected to receive similar exposure patterns as the children because they spend the workday close to them. Thus they can stand as proxies for estimation of exposures of children.Volunteers belonging to one of two groups (elementary school teachers, n = 31; employees of kindergartens and day nurseries, n = 50) in Hungarian cities received a Personal Exposimeter (PEM) for 24 h each. Only workdays, when the volunteers worked near children, were considered. 51 additional volunteers (office workers) were measured as controls.The volunteers wore the PEMs on their bodies. Those activities marked in the exposure diaries as work were further classified into 5 categories based on the level of certainty that they actually worked near children during that activity. Subsets of the full dataset were derived and compared based on this categorization.It was found that relaxation of the selection criteria often under- or overestimates exposure. The differences of estimation depend on the frequency band and sub-population: the kindergarten and teacher groups differ in this regard. For most frequency bands the majority of data points was below the detection limit. Derived child exposures are comparable to the worktime exposure of adults (control group).  相似文献   

5.
Personal radio frequency electromagnetic field (RF-EMF) exposure, or exposimetry, is gaining importance in the bioelectromagnetics community but only limited data on personal exposure is available in indoor areas, namely schools, crèches, homes, and offices. Most studies are focused on adult exposure, whereas indoor microenvironments, where children are exposed, are usually not considered. A method to assess spatial and temporal indoor exposure of children and adults is proposed without involving the subjects themselves. Moreover, maximal possible daily exposure is estimated by combining instantaneous spatial and temporal exposure. In Belgium and Greece, the exposure is measured at 153 positions spread over 55 indoor microenvironments with spectral equipment. In addition, personal exposimeters (measuring EMFs of people during their daily activities) captured the temporal exposure variations during several days up to one week at 98 positions. The data were analyzed using the robust regression on order statistics (ROS) method to account for data below the detection limit. All instantaneous and maximal exposures satisfied international exposure limits and were of the same order of magnitude in Greece and Belgium. Mobile telecommunications and radio broadcasting (FM) were most present. In Belgium, digital cordless phone (DECT) exposure was present for at least 75% in the indoor microenvironments except for schools. Temporal variations of the exposure were mainly due to variations of mobile telecommunication signals. The exposure was higher during daytime than at night due to the increased voice and data traffic on the networks. Total exposure varied the most in Belgian crèches (39.3%) and Greek homes (58.2%).  相似文献   

6.
This article presents the measurement results of human exposure to CDMA800 and CDMA1800 signals at locations in Korea where the general public has expressed concern. Measurements were performed at 50 locations across the country to compare the electromagnetic field levels with the general public exposure compliance limits. At each site, the distances between the nearest single or co‐located base station and measurement positions were within a range of approximately 32–422 m. The measured exposure levels were very low compared with the international standard and the Korean human protection notice. The highest field level was 1.5 V/m, which corresponds to 0.15% of the International Commission on Non‐Ionizing Radiation Protection (ICNIRP) guidelines for human exposure. Bioelectromagnetics 31:495–498, 2010. © 2010 Wiley‐Liss, Inc.  相似文献   

7.
A space efficient, whole body microwave exposure system for unrestrained laboratory animals utilizing a flared parallel plate waveguide is described. The system comprises an Iridium wireless signal source, signal generator, power supply and amplifier (400 W), a coax to waveguide transition, an open ended, flared parallel plate waveguide, and animal exposure area with a dipole field sensing antenna. Across the waveguide aperture the system provides uniform exposure (+/-3 dB incident RF power density) for small animals (rats, mice or hamsters) in up to 18 standard cages for housing groups of animals. Overall system dimensions are 3.6 m (d)x2.4 m (w)x1.6 m (h). Operating at 1.62 GHz, the system provided average power density of 3.7 W/m(2) in the cage area, resulting in a calculated whole body dose of 0.07 W/kg and a calculated average brain dose of 0.19 W/kg.  相似文献   

8.
This article is a consensus position statement from the Research Committee of the Organization of Teratology Information Specialists (OTIS). The Committee believes that more specific information on the timing and dose of drug exposures from pregnancy birth defect registries sponsored by pharmaceutical companies (herein called pregnancy registries) would improve the estimation of risk for developmental toxicity (i.e., growth alteration, structural anomalies, functional/neurobehavioral deficits, or death). Specifically, the Committee believes that the exposure timing should be stated in gestational weeks and days rather than simply weeks. In addition, the Committee believes that the exposure dose should be stated in patient‐specific terms, such as body weight (mg/kg) or body surface area (mg/m2) rather than simply dose strength. Although the focus of this position is pregnancy registries, it also is applicable to any source of medication‐induced embryo‐fetal toxicity. Birth Defects Research (Part A), 2009. © 2008 Wiley‐Liss, Inc.  相似文献   

9.
10.
The purpose of this study was to estimate the daily exposure to lead due to food ingestion, air inhalation, and soil ingestion in the Republic of Korea's general population, and to evaluate the level of risk associated with the current lead exposure level using the proportional daily dose (3–4 μg/kg body weight/day) corresponding to the Provisional Tolerable Weekly Intake (PTWI) suggested by the Joint FAO/WHO Expert Committee on Food Additives as the toxicological tolerance level. The estimation of the daily exposure to lead via three pathways including food, soil ingestion and air inhalation was conducted as a chronic exposure assessment. For the lead exposure assessment through dietary intake, 1,389 lead residue data for 45 commodities investigated by the Korea Food and Drug Administration during the period 1995–2000 were utilized (KFDA 1996, 1997, 1998). Six hundred seventy-two air monitoring data from 7 major cities during the period 1993–2000 and 4,500 soil residue data at 1,500 sites during the period 1999–2001 were considered for the lead exposure assessment involving air inhalation and soil ingestion, respectively. The total daily exposure to lead was estimated by combining dietary intake, inhaled amount and soil intake corresponding to the typical activity of the general population, which was treated as a group of adults with a body weight of 60 kg. For risk characterization, the daily exposure to lead was compared with the toxicological tolerance level. The level of risk due to lead exposure was calculated using the hazard ratio (HR). The dietary intake of lead was 9.71 × 10?4 mg/kg/day and the total daily exposure level, including air inhalation and soil ingestion, was 9.97 × 10?4 mg/kg/day. The exposure contributions of foods, air and soil induced from the percentage of each media to the total daily exposure were 97.4%, 2.1% and 0.5%, respectively. Of the different commodity groups, the highest contribution to the total exposure came from grain, which represented 47.7% of the total. Additional exposure to lead occurs in certain population groups due to the use of tobacco, alcoholic beverages, and the intake of other foods, all factors not considered in this study. Through the comparison of the daily exposure to lead with the tolerance level based on the PTWI, the hazard ratio was estimated as being 0.25–0.33. This value implies that no increase in blood lead level is to be expected in the general population at the current lead exposure levels.  相似文献   

11.
A preliminary assessment of the cumulative exposure to heavy metals among Finnish preschool children is reported. Cadmium, lead, arsenic,and mercury affect many of the same organs in the human body. The effects are mostly caused by oxidative stress or disruption of enzyme function. The cumulative effects of the heavy metals on the central nervous system and on the kidneys are determined based on national concentration and consumption data, and comparison of the relative toxicity of the heavy metals is based on dose–response values found in the literature. The cumulative effects were assumed to be additive. The main contributors to kidney toxicity among the studied population groups were cadmium and lead, while lead was the main contributor to neurotoxic effects.  相似文献   

12.
Static magnetic fields (SMFs) and time-varying electromagnetic fields exposure is necessary to obtain the diagnostic information regarding the structure of patient's tissues, by the use of magnetic resonance imaging (MRI) scanners. A diagnostic procedure may also include the administration of pharmaceuticals called contrast, which are to be applied to a patient during the examination. The nurses involved in administering contrast into a patient during the pause in examination are approaching permanently active magnets of MRI scanners and are exposed to SMF. There were performed measurements of spatial distribution of SMF in the vicinity of MRI magnets and parameters of personal exposure of nurses (i.e. individual exposimetric profiles of variability in time of SMF affecting the nurse who is performing tasks in the vicinity of magnet, characterized by statistical parameters of recorded magnetic flux density affecting the nurse). The SMF exposure in the vicinity of various MRI magnets depends on both magnetic flux density of the main field B 0 (applicable to a patient) and the construction of the scanner, but the most important factor determining the workers' exposure is the work practice. In the course of a patient's routine examination in scanners of B 0 = 1.5 T, the nurses are present over ~0.4–2.9 min in SMF exceeding 0.03% of B 0 (i.e. 0.5 mT), but only sometimes they are present in SMF exceeding 5% of B 0 (i.e. 75 mT). When patients need more attention because of their health status/condition, the nurses' exposure may be significantly longer – it may even exceed 10 min and 30% of B 0 (i.e. 500 mT). We have found that the level of exposure of nurses to SMF may vary from < 5% of the main field (a median value: 0.5–1.5%; inter-quartile range: 0.04–8.8%; max value: 1.3–12% of B 0) when a patient is moved from the magnets bore before contrast administration, up to the main field level (B 0) when a patient stays in the magnets bore and nurse is crawling into the bore.  相似文献   

13.
Physiological processes in organisms can be influenced by extremely low-frequency (ELF) electromagnetic energy. Biological effect studies have great importance; as well as measurement studies since they provide information on the real exposure situations. In this study, the leakage magnetic fields around a transformer were measured in an apartment building in Küçükçekmece, Istanbul, and the measurement results were evaluated with respect to the international exposure standards. The transformer station was on the bottom floor of a three-floor building. It was found that people living and working in the building were exposed to ELF magnetic fields higher than the threshold magnetic field value of the International Agency for Research on Cancer (IARC). Many people living in this building reported health complaints such as immunological problems of their children. There were child-workers working in the textile factories located in the building. Safe distances or areas for these people should be recommended. Protective measures could be implemented to minimize these exposures. Further residential exposure studies are needed to demonstrate the exposure levels of ELF magnetic fields. Precautions should, therefore, be taken either to reduce leakage or minimize the exposed fields. Shielding techniques should be used to minimize the leakage magnetic fields in such cases.  相似文献   

14.
The aim of this work was to study the exposure to magnetic fields of children living at different distances from a power line and to evaluate how well theoretical calculations compared with actual exposure. Personal exposure instruments were carried for 24 h by 65 schoolchildren living 28–325 m from a 300 kV transmission line; the current load was 200–700 A. About half of the children attended a school far from the power line, whereas the other half attended a school located about 25 m from the line. Exposure to magnetic fields was analyzed for three categories of location: at home, at school, and at all other places. Time spent in bed was analyzed separately. The results indicated that children who lived close to a power line had a higher magnetic field exposure than other children. The power line was the most important source of exposure when the magnetic field due to the line was greater than about 0.2 μT. Exposure at school influenced the 24 h time-weighted average results considerably in those cases where the distance between home and power line was very different from the distance between school and power line. The calculated magnetic field, based on line configuration, current load, and distance between home and power line, corresponded reasonably well with the measured field. However, the correlation depends on whether home only or 24 h exposure is used in the analysis and on which school the children attended. The calculated magnetic field seems to be a reasonably good predictor of actual exposure and could be used in epidemiological studies, at least in Norway, where the electrical system normally results in less ground current than in most other countries. Bioelectromagnetics 18:47–57, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

15.
Abstract

The introduction of the pesticide registration system in pesticide risk assessments has promoted the scientific and safe use of pesticides, and the assessment of occupational exposure risk. In the present study, we performed an experiment in a citrus orchard subject to normal orchard management practices. By measuring the exposure of applicators’ (farmers and technicians) body parts to 45% malathion emulsifiable concentrate during its application using electric backpack sprayers (0.25?KPa) and stretcher-mounted sprayers (1.5?KPa), the unit exposure (UE) was determined. The risks of exposure for pesticide applicators who adopted five different protective measures (A: no personal protective equipment (PPE), i.e., no clothes, no gloves, no caps, and no socks; B: short-sleeved top and shorts; C: short-sleeved top, shorts, and a single pair of gloves; D: short-sleeved top, shorts, a single pair of gloves, and a cap; E: long-sleeved top, long pants, a single pair of gloves, and a cap) were also assessed. The results were as follows: 1) The total levels of exposure for pesticide applicators using electric backpack sprayers and stretcher-mounted sprayers were 3613.63?µg and 5654.28?µg, respectively. When electric backpack sprayers were used, the body parts that had the highest exposure were the head (13.8%), hands (19.9%) and back (14.0%), and when stretcher-mounted sprayers were used, the hands (32.5%) and lower legs (21.1%) had the highest level of exposure; 2) In the absence of PPE, the UE values for farmers who used electric backpack sprayers and farmers who used stretcher-mounted sprayers were significantly different. However, when PPE was used, the difference in UE values between the farmers using the two different types of sprayers was not significant; 3) When protective measure A was adopted, the risk quotient (RQ) values of the farmers and technicians who used electric backpack sprayers for the application of malathion were 1.44 and 0.54, respectively; the corresponding RQ values when protective measure B was adopted were 0.97 and 0.28, respectively. When stretcher-mounted sprayers were used for the application of chlorpyrifos, the RQ value of the farmers who adopted protective measure E was 0.43 while other types of PPE use resulted in RQ values greater than 1. In contrast, the RQ value for technicians was 1.62 when protective measure A was used and 1.02 when protective measure B was adopted, whereas other types of PPE use resulted in RQ values less than 1. Therefore, besides increasing the awareness of personal protection among pesticide applicators, improvement in the management of pesticide use and the enhancement of standard operations are of practical significance for controlling occupational exposure to pesticides.  相似文献   

16.
Buildings with indoor transformer stations may serve as a basis for improved epidemiological studies on the health effects of extremely low-frequency magnetic fields (ELF MFs). Previous studies have shown that ELF MF exposure can be adequately assessed based on the fact that MF levels are high in apartments directly above transformers. In this paper, we describe the creation of a registry of Finnish residential buildings with built-in transformer stations and discuss its usability in epidemiological studies. Information obtained from electric utilities and building blueprints were used to identify 677 buildings in which an apartment was located above or adjacent to a transformer station. All apartments in these buildings were classified into exposure categories based on their location in relation to the transformer. Residential histories of these buildings were obtained from the Population Register Centre. Out of the 287,668 individuals who have resided in the buildings, 9,126 of them have resided in an apartment located directly above a transformer station. All information was collected without contacting residents, thus avoiding selection bias. The registry can be linked with data from high-quality nationwide registries to confirm or challenge the reported associations of ELF MF exposure and diseases such as cancer, miscarriage, and Alzheimer's disease. Bioelectromagnetics. 2020;41:34–40 © 2019 Bioelectromagnetics Society.  相似文献   

17.
The facility consists of a 12 × 11.5 × 2.4 m high room containing six sets of exposure apparatus and the other equipment necessary to maintain a pathogen-free system. The apparatus sets produced 5 mT (rms), 0.5 mT, or a sham exposure. The apparatus was arranged in the room to minimize the fringing field of the 5 mT set at the sham position. Each set was 3.85 × 1.80 × 0.66 m in outside dimension, containing 24 cages in the magnetically homogeneous region. The apparatus was designed using Harvey's figure-eight-configuration and generated a horizontal sinusoidal alternating field. In order to save electric power, the coil of the apparatus constituted a 50 Hz LC resonance circuit with a condensor bank to which electric power was supplied to compensate losses. Magnetic flux density was kept constant by controlling the coil current. Although mild steel was used in the skeleton of the building, the fringing flux at the sham was as low as 0.1 to 1 μT. Stainless steel was used for ventilating ducts, racks for the cages, cage covers, feeder baskets, and watering nozzles. The homogeneity of the field was measured to be ± 10% in the animal residence area, and food and water consumption was found to be unaffected by the field. At 5 mT, the coil current was 370 A, and the hollow coil was cooled by a stream of 20°C water to prevent both heat and dew on the coil surface. Vibration and acoustic noise was prevented by fiber reinforced plastic framework of the coil. High harmonic distortion was not observed at the output terminal of the coil driver. The facility has operated without trouble for 2 years. © 1993 Wiley-Liss, Inc.  相似文献   

18.
BackgroundThe immunotoxicity induced by vanadium exposure have been reported in some toxicology researches. However, evidence from population-based epidemiological studies was lacking.MethodsThis study was conducted to assess the associations between prenatal and postnatal exposure to vanadium and immune function of children. A total of 407 pre-school aged children were followed, whose peripheral blood was collected for T lymphocyte subsets and inflammatory cytokines analysis, as well as vanadium concentration measurement. Maternal urine samples were also collected to measure vanadium concentration. We used generalized linear models to evaluate the associations of maternal and children vanadium concentration with children’s immune function. Stratification analysis was further conducted to explore the potential gender-specific effects.ResultsThe geometric means of vanadium concentration in maternal urine and children plasma were 0.85 and 1.12 μg/L, respectively. Maternal urinary vanadium was inversely associated with the percentage of CD3+CD4+ cells [-5.53 % (-10.38 %, -0.41 %)] and absolute counts of CD3+ cells [-2.43 % (-5.05 %, 0.25 %)], and we only observed significant negative associations in males when stratifying by fetal gender. Children plasma vanadium was also associated with reduced absolute counts of CD3+ cells [-5.25 % (-9.57 %, -0.73 %)], but gender-specific effects were not observed. No significant associations of vanadium exposure with cytokines were found.ConclusionsPrenatal and postnatal exposure to vanadium had suppressive impacts on childhood cellular immune. Further studies are needed to confirm our findings.  相似文献   

19.
Power density distribution inside a water sample placed between two parallel lossy dielectric plates (Polystyrene) was calculated using Fresnel equations for the frequency range of 42.25-53.57 GHz. Due to the multiple internal reflections from the sample boundaries, the distribution of the power density within the thin sample is more uniform than that within a semi-infinite medium. The power density in a sample depends on the thicknesses of the sample and the adjacent dielectric plates. For the given frequency range the sample thickness optimal for power density uniformity varies between 0.28 and 0.33 mm. The front plate has a significant effect on the magnitude of the power density within the sample but little effect on the power density distribution. The thicker the rear plate, the greater is the non uniformity of the power density distribution within the sample. Based on the calculated data, we determined the dimension of an exposure chamber providing the optimal power density distribution uniformity for mm-wave irradiation.  相似文献   

20.
The incomplete understanding of the relation between power-frequency fields and biological responses raises problems in defining an appropriate metric for exposure assessment and epidemiological studies. Based on evidence from biological experiments, one can define alternative metrics or effects functions that embody the relationship between field exposure patterns and hypothetical health effects. In this paper, we explore the application of the “effects function” approach to occupational exposure data. Our analysis provides examples of exposure assessments based on a range of plausible effects functions. An EMDEX time series data set of ELF frequency (40–800 Hz) magnetic field exposure measurements for electric utility workers was analyzed with several statistical measures and effects functions: average field strength, combination of threshold and exposure duration, and field strength changes. Results were compared for eight job categories: electrician, substation operator, machinist, welder, plant operator, lineman/splicer, meter reader, and clerical. Average field strength yields a different ranking for these job categories than the ranks obtained using other biologically plausible effects functions. Whereas the group of electricians has the highest exposure by average field strength, the group of substation operators has the highest ranking for most of the other effects functions. Plant operators rank highest in the total number of field strength changes greater than 1 μT per hour. The clerical group remains at the lowest end for all of these effects functions. Our analysis suggests that, although average field strength could be used as a surrogate of field exposure for simply classifying exposure into “low” and “high,” this summary measure may be misleading in the relative ranking of job categories in which workers are in “high” fields. These results indicate the relevance of metrics other than average field strength in occupational exposure assessment and in the design and analysis of epidemiological studies. Bioelectromagnetics 18:365–375, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号