首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Sedimentation data acquired with the interference optical scanning system of the Optima XL-I analytical ultracentrifuge can exhibit time-invariant noise components, as well as small radial-invariant baseline offsets, both superimposed onto the radial fringe shift data resulting from the macromolecular solute distribution. A well-established method for the interpretation of such ultracentrifugation data is based on the analysis of time-differences of the measured fringe profiles, such as employed in the g(s*) method. We demonstrate how the technique of separation of linear and nonlinear parameters can be used in the modeling of interference data by unraveling the time-invariant and radial-invariant noise components. This allows the direct application of the recently developed approximate analytical and numerical solutions of the Lamm equation to the analysis of interference optical fringe profiles. The presented method is statistically advantageous since it does not require the differentiation of the data and the model functions. The method is demonstrated on experimental data and compared with the results of a g(s*) analysis. It is also demonstrated that the calculation of time-invariant noise components can be useful in the analysis of absorbance optical data. They can be extracted from data acquired during the approach to equilibrium, and can be used to increase the reliability of the results obtained from a sedimentation equilibrium analysis.  相似文献   

2.
Schuck P  Rossmanith P 《Biopolymers》2000,54(5):328-341
A new method is presented for the calculation of apparent sedimentation coefficient distributions g*(s) for the size-distribution analysis of polymers in sedimentation velocity experiments. Direct linear least-squares boundary modeling by a superposition of sedimentation profiles of ideal nondiffusing particles is employed. It can be combined with algebraic noise decomposition techniques for the application to interference optical ultracentrifuge data at low loading concentrations with significant systematic noise components. Because of the use of direct boundary modeling, residuals are available for assessment of the quality of the fits and the consistency of the g*(s) distribution with the experimental data. The method can be combined with regularization techniques based on F statistics, such as used in the program CONTIN, or alternatively, the increment of s values can be adjusted empirically. The method is simple, has advantageous statistical properties, and reveals precise sedimentation coefficients. The new least-squares ls-g*(s) exhibits a very high robustness and resolution if data acquired over a large time interval are analyzed. This can result in a high resolution for large particles, and for samples with a high degree of heterogeneity. Because the method does not require a high frequency of scans, it can also be easily used in experiments with the absorbance optical scanning system. Published 2000 John Wiley & Sons, Inc.  相似文献   

3.
P Schuck 《Biophysical journal》1998,75(3):1503-1512
The potential of using the Lamm equation in the analysis of hydrodynamic shape and gross conformation of proteins and reversibly formed protein complexes from analytical ultracentrifugation data was investigated. An efficient numerical solution of the Lamm equation for noninteracting and rapidly self-associating proteins by using combined finite-element and moving grid techniques is described. It has been implemented for noninteracting solutes and monomer-dimer and monomer-trimer equilibria. To predict its utility, the error surface of a nonlinear regression of simulated sedimentation profiles was explored. Error contour maps were calculated for conventional independent and global analyses of experiments with noninteracting solutes and with monomer-dimer systems at different solution column heights, loading concentrations, and centrifugal fields. It was found that the rotor speed is the major determinant for the shape of the error surface, and that global analysis of different experiments can allow substantially improved characterization of the solutes. We suggest that the global analysis of the approach to equilibrium in a short-column sedimentation equilibrium experiment followed by a high-speed short-column sedimentation velocity experiment can result in sedimentation and diffusion coefficients of very high statistical accuracy. In addition, in the case of a protein in rapid monomer-dimer equilibrium, this configuration was found to reveal the most precise estimate of the association constant.  相似文献   

4.
MultiSig is a newly developed mode of analysis of sedimentation equilibrium (SE) experiments in the analytical ultracentrifuge, having the capability of taking advantage of the remarkable precision (~0.1 % of signal) of the principal optical (fringe) system employed, thus supplanting existing methods of analysis through reducing the ‘noise’ level of certain important parameter estimates by up to orders of magnitude. Long-known limitations of the SE method, arising from lack of knowledge of the true fringe number in fringe optics and from the use of unstable numerical algorithms such as numerical differentiation, have been transcended. An approach to data analysis, akin to ‘spatial filtering’, has been developed, and shown by both simulation and practical application to be a powerful aid to the precision with which near-monodisperse systems can be analysed, potentially yielding information on protein-solvent interaction. For oligo- and poly-disperse systems the information returned includes precise average mass distributions over both cell radial and concentration ranges and mass-frequency histograms at fixed radial positions. The application of MultiSig analysis to various complex heterogenous systems and potentially multiply-interacting carbohydrate oligomers is described.  相似文献   

5.
Analytical ultracentrifugation remains pre-eminent among the methods used to study the interactions of macromolecules under physiological conditions. Recent developments in analytical procedures allow the high resolving power of sedimentation velocity methods to be coupled to sedimentation equilibrium approaches and applied to both static and dynamic associations. Improvements in global modeling based on numerical solutions of the Lamm equation have generated new sedimentation velocity applications with an emphasis on data interpretation using sedimentation coefficient or molar mass distributions. Procedures based on the use of multiple optical signals from absorption and interference optics for the analysis of the sedimentation velocity and equilibrium behavior of more complex interactions have now been developed. New applications of tracer sedimentation equilibrium experiments and the development of a fluorescence optical system for the analytical ultracentrifuge extend the accessible concentration range over several orders of magnitude and, coupled with the new analytical procedures, provide powerful new tools for studies of both weak and strong macromolecular interactions in solution.  相似文献   

6.
Computation of the dipole moments of proteins.   总被引:1,自引:0,他引:1       下载免费PDF全文
A simple and computationally feasible procedure for the calculation of net charges and dipole moments of proteins at arbitrary pH and salt conditions is described. The method is intended to provide data that may be compared to the results of transient electric dichroism experiments on protein solutions. The procedure consists of three major steps: (i) calculation of self energies and interaction energies for ionizable groups in the protein by using the finite-difference Poisson-Boltzmann method, (ii) determination of the position of the center of diffusion (to which the calculated dipole moment refers) and the extinction coefficient tensor for the protein, and (iii) generation of the equilibrium distribution of protonation states of the protein by a Monte Carlo procedure, from which mean and root-mean-square dipole moments and optical anisotropies are calculated. The procedure is applied to 12 proteins. It is shown that it gives hydrodynamic and electrical parameters for proteins in good agreement with experimental data.  相似文献   

7.
Sedimentation equilibrium is a powerful tool for the characterization of protein self-association and heterogeneous protein interactions. Frequently, it is applied in a configuration with relatively long solution columns and with equilibrium profiles being acquired sequentially at several rotor speeds. The present study proposes computational tools, implemented in the software SEDPHAT, for the global analysis of equilibrium data at multiple rotor speeds with multiple concentrations and multiple optical detection methods. The detailed global modeling of such equilibrium data can be a nontrivial computational problem. It was shown previously that mass conservation constraints can significantly improve and extend the analysis of heterogeneous protein interactions. Here, a method for using conservation of mass constraints for the macromolecular redistribution is proposed in which the effective loading concentrations are calculated from the sedimentation equilibrium profiles. The approach is similar to that described by Roark (Biophys. Chem. 5 (1976) 185-196), but its utility is extended by determining the bottom position of the solution columns from the macromolecular redistribution. For analyzing heterogeneous associations at multiple protein concentrations, additional constraints that relate the effective loading concentrations of the different components or their molar ratio in the global analysis are introduced. Equilibrium profiles at multiple rotor speeds also permit the algebraic determination of radial-dependent baseline profiles, which can govern interference optical ultracentrifugation data, but usually also occur, to a smaller extent, in absorbance optical data. Finally, the global analysis of equilibrium profiles at multiple rotor speeds with implicit mass conservation and computation of the bottom of the solution column provides an unbiased scale for determining molar mass distributions of noninteracting species. The properties of these tools are studied with theoretical and experimental data sets.  相似文献   

8.
Fluorescence optical detection in sedimentation velocity analytical ultracentrifugation allows the study of macromolecules at nanomolar concentrations and below. This has significant promise, for example, for the study of systems of high-affinity protein interactions. Here we describe adaptations of the direct boundary modeling analysis approach implemented in the software SEDFIT that were developed to accommodate unique characteristics of the confocal fluorescence detection system. These include spatial gradients of signal intensity due to scanner movements out of the plane of rotation, temporal intensity drifts due to instability of the laser and fluorophores, and masking of the finite excitation and detection cone by the sample holder. In an extensive series of experiments with enhanced green fluorescent protein ranging from low nanomolar to low micromolar concentrations, we show that the experimental data provide sufficient information to determine the parameters required for first-order approximation of the impact of these effects on the recorded data. Systematic deviations of fluorescence optical sedimentation velocity data analyzed using conventional sedimentation models developed for absorbance and interference optics are largely removed after these adaptations, resulting in excellent fits that highlight the high precision of fluorescence sedimentation velocity data, thus allowing a more detailed quantitative interpretation of the signal boundaries that is otherwise not possible for this system.  相似文献   

9.
Schuck P 《Biophysical journal》2000,78(3):1606-1619
A new method for the size-distribution analysis of polymers by sedimentation velocity analytical ultracentrifugation is described. It exploits the ability of Lamm equation modeling to discriminate between the spreading of the sedimentation boundary arising from sample heterogeneity and from diffusion. Finite element solutions of the Lamm equation for a large number of discrete noninteracting species are combined with maximum entropy regularization to represent a continuous size-distribution. As in the program CONTIN, the parameter governing the regularization constraint is adjusted by variance analysis to a predefined confidence level. Estimates of the partial specific volume and the frictional ratio of the macromolecules are used to calculate the diffusion coefficients, resulting in relatively high-resolution sedimentation coefficient distributions c(s) or molar mass distributions c(M). It can be applied to interference optical data that exhibit systematic noise components, and it does not require solution or solvent plateaus to be established. More details on the size-distribution can be obtained than from van Holde-Weischet analysis. The sensitivity to the values of the regularization parameter and to the shape parameters is explored with the help of simulated sedimentation data of discrete and continuous model size distributions, and by applications to experimental data of continuous and discrete protein mixtures.  相似文献   

10.
Various ways of applying differential interferometry to ultracentrifugal analyses are examined and several analytical techniques are established. In transport and moving boundary methods, the sedimentation coefficient is more precisely determined in the differential interference system than in the schlieren optical system because fringe measurement accuracy is much higher in the former system. Compared to interference and absorption optics, the differential interferometer provides a more exact s value in the transport method since an accurate calculation procedure can be adopted. Moreover, the following advantages of differential interferometry are noted. Determination of the initial solute concentration, which must be done in the usual interference method, is unnecessary in this sedimentation equilibrium method. Regardless of the partial loss of solute from the observed system due to rapid precipitation or adsorption to the cell wall during centrifugation, the molecular weight of the rest of the solute can be determined exactly. The diffusion coefficient can be determined accurately by fringe displacement analysis at the hinge point during the transient state. Together with the molecular weight and diffusion coefficient, the partial specific volume and sedimentation coefficient of a solute can be obtained from the result of a single low-speed centrifugation when the sample solutions in H2O and D2O are compared.  相似文献   

11.
Analytical ultracentrifugation (AUC) provides first-principle hydrodynamic and thermodynamic information concerning the size, shape and interactions of macromolecules. The fundamental measurement needed in AUC is the macromolecular concentration as a function of radial position and time. Currently, the Beckman Coulter XLI analytical ultracentrifuge may be equipped with absorbance and refractive detectors, which provide complementary concentration determinations. For detecting trace quantities of materials, fluorescence detection offers unique advantages over either absorbance or interference detection. A prototype fluorescence detector for the XLI analytical ultracentrifuge has been developed and its characteristics determined. An Ar(+) laser provides a continuous 488-nm excitation beam. Radial resolution is achieved by scanning the focused beam along a radial axis. Detection of the fluorescence signal uses a co-axial, front-face optical configuration to reduce inaccuracies in the concentration caused by inner filter effects. A high-speed A/D data acquisition system allows the fluorescence intensity to be monitored continuously and at a sufficiently high angular resolution so that at any radial position the intensities from all of the samples may be acquired at each revolution. The fluorescence detector is capable of detecting concentrations as low as 300 pM for fluorescein-like labels. The radial resolution of the fluorescence detector is comparable to that of the absorbance system. Both sedimentation velocity and sedimentation equilibrium measurements may be made with the fluorescence detector. Results are presented comparing data acquired using the fluorescence with those acquired using the absorbance detector.  相似文献   

12.
Brown PH  Balbo A  Zhao H  Ebel C  Schuck P 《PloS one》2011,6(10):e26221
The partial-specific volume of proteins is an important thermodynamic parameter required for the interpretation of data in several biophysical disciplines. Building on recent advances in the use of density variation sedimentation velocity analytical ultracentrifugation for the determination of macromolecular partial-specific volumes, we have explored a direct global modeling approach describing the sedimentation boundaries in different solvents with a joint differential sedimentation coefficient distribution. This takes full advantage of the influence of different macromolecular buoyancy on both the spread and the velocity of the sedimentation boundary. It should lend itself well to the study of interacting macromolecules and/or heterogeneous samples in microgram quantities. Model applications to three protein samples studied in either H(2)O, or isotopically enriched H(2) (18)O mixtures, indicate that partial-specific volumes can be determined with a statistical precision of better than 0.5%, provided signal/noise ratios of 50-100 can be achieved in the measurement of the macromolecular sedimentation velocity profiles. The approach is implemented in the global modeling software SEDPHAT.  相似文献   

13.
Gleaning information regarding the molecular physiology of macromolecular complexes requires knowledge of their component stoichiometries. In this work, a relatively new means of analyzing sedimentation velocity (SV) data from the analytical ultracentrifuge is examined in detail. The method depends on collecting concentration profile data simultaneously using multiple signals, like Rayleigh interferometry and UV spectrophotometry. If the cosedimenting components of a complex are spectrally distinguishable, continuous sedimentation-coefficient distributions specific for each component can be calculated to reveal the molar ratio of the complex's components. When combined with the hydrodynamic information available from the SV data, a stoichiometry can be derived. Herein, the spectral properties of sedimenting species are systematically explored to arrive at a predictive test for whether a set of macromolecules can be spectrally resolved in a multisignal SV (MSSV) experiment. Also, a graphical means of experimental design and criteria to judge the success of the spectral discrimination in MSSV are introduced. A detailed example of the analysis of MSSV experiments is offered, and the possibility of deriving equilibrium association constants from MSSV analyses is explored. Finally, successful implementations of MSSV are reviewed.  相似文献   

14.
A method is described for the sedimentation velocity analysis of solutions composed of macromolecular solutes of widely disparate size. In sedimentation velocity experiments, usually a single rotor speed is chosen for the entire run, and consequently, the range of observable sedimentation coefficients can be severely limited. This limitation can be removed if the speed is varied during the run, starting with a relatively low speed so that the largest particles can be easily observed. The speed is increased during the run until full speed is attained and the run continued at full speed until the smallest species of interest have cleared the solution. The method, called wide distribution analysis, is based on the method developed originally by Yphantis and co-workers (Proc. Natl. Acad. Sci. USA 78 (1981) 1431) and on the time derivative method of Stafford (Anal. Biochem. 203 (1992) 295), essentially eliminating both the time-independent and radially-independent noise thereby improving the precision, especially for interference optics. An algorithm for analysis of data from both absorbance and interference optics and experimental protocols compatible with the Beckman XL-I Analytical Ultracentrifuge are presented. With these protocols an extremely wide range of sedimentation coefficients from approximately 1.0 to 250000 S can be accommodated in a single multi-speed run.  相似文献   

15.
Tetanus toxoid protein has been characterized with regard oligomeric state and hydrodynamic (low-resolution) shape, important parameters with regard its use in glycoconjugate vaccines. From sedimentation velocity and sedimentation equilibrium analysis in the analytical ultracentrifuge tetanus toxoid protein is shown to be mostly monomeric in solution (~86%) with approximately 14% dimer. The relative proportions do not appear to change significantly with concentration, suggesting the two components are not in reversible equilibrium. Hydrodynamic solution conformation studies based on high precision viscometry, combined with sedimentation data show the protein to be slightly extended conformation in solution with an aspect ratio ~3. The asymmetric structure presents a greater surface area for conjugation with polysaccharide than a more globular structure, underpinning its popular choice as a conjugation protein for glycoconjugate vaccines.  相似文献   

16.
A method is proposed for the selection of experimental conditions for sedimentation equilibrium experiments that will provide maximal information about the values of equilibrium association constants within a given scheme for heteroassociation of two solute components. A discriminator function is proposed that indicates the sensitivity of the experimentally observed gradient or gradients to alterations in the underlying association constants. The value of this function is plotted or tabulated as a function of the concentrations of the two components, over a broad range of solution compositions. It is suggested that experiments performed with loading compositions corresponding to large absolute values of the discriminator function will yield the most information with respect to determination of the underlying association constants. This method was tested by predicting optimal conditions for three different types of sedimentation equilibrium experiments: (i) measurement of total (natural) solute absorbance; (ii) measurement of individual component gradients via measurement of tracer absorbance; and (iii) global analysis of multiple experiments. Experimental data resulting from sedimentation equilibrium experiments carried out under the specified conditions were simulated by addition of realistic levels of random error to calculated equilibrium gradients. The simulated data were then analyzed exactly as real experimental data, i.e., without prior knowledge of the underlying association constants. It was found that the highest accuracy and precision in determination of heteroassociation constants are obtained by global analysis of multiple experiments performed using significantly different loading compositions, each of which is selected from 'sensitive' regions of the discriminator map.  相似文献   

17.
Methods for quantitative characterization of heterologous protein-protein interactions by means of analytical ultracentrifugation (AUC) include sedimentation equilibrium, tracer sedimentation equilibrium, sedimentation velocity, and analytical band sedimentation. Fundamental principles governing the behavior of macromolecules in a centrifugal field are summarized, and the application of these principles to the interpretation of data obtained from each type of experiment is reviewed. Instrumentation and software for the acquisition and analysis of data obtained from different types of AUC experiments are described.  相似文献   

18.
For structural studies of integral membrane proteins, including their 3D crystallization, the judicious use of detergent for solubilization and purification is required. Detergent binding by the solubilized protein is an important parameter to determine the hydrodynamic properties in terms of size and aggregational (monomeric/oligo(proto)meric) state of the protein. Detergent binding can be measured by gel filtration chromatography under equilibrium conditions and after separation from mixed micelles of solubilized lipid and detergent. Using sarcoplasmic reticulum Ca(2+)-ATPase as an example, we demonstrate in this protocol complete procedures for measurement of detergent binding using (i) radiolabeled n-dodecyl-beta-D-maltoside (DM) or (ii) from measurements of the increase in refractive index due to the presence of bound detergent on the protein. The latter measurement can also be performed by sedimentation velocity (SV) analysis in the analytical ultracentrifuge which in addition allows determination of the sedimentation coefficient. In combination with estimation of Stokes radius by gel filtration calibration, the molecular mass and asymmetry of the solubilized protein can be calculated. In the proposed protocols, the gel chromatographic procedures require 1 d; SV experiments are performed just after size exclusion. The whole time for these experiments is 24 h. Data analysis of analytical ultracentrifugation requires a couple of days.  相似文献   

19.
This paper describes a program available for PC's for the evaluation of molecular weights from sedimentation equilibrium. This program, in its two forms – MSTARA for absorption optical records and MSTARI for interference optical records – requires no prior assumption of the nature of the system (ideal, non-ideal, monodisperse, polydisperse, self-associating etc.) and takes into consideration the whole solute distribution (i.e. from solution meniscus to cell base) in the ultracentrifuge cell rather than just a selected data-set. MSTARA or MSTARI are therefore recommended as a first analysis programme of sedimentation equilibrium data coming off an absorption or interference based analytical ultracentrifuge. These programmes are therefore particularly well suited if heterogeneity (polydispersity or interaction phenomena) or non-ideality is suspected. Their use is demonstrated for a series of data-set types (ideal, non-ideal, polydisperse and self-associating). Although MSTARA and MSTARI are model independent, they provide the basis for more detailed analysis of interactions, polydisperse distributions or non-ideality via easy export of ASCII datafiles to model dependent routines. Received: 4 November 1996 / Accepted: 15 November 1996  相似文献   

20.
Quaternary solution structures of galectins-1, -3, and -7   总被引:4,自引:0,他引:4  
Galectins are a growing family of animal lectins with functions in growth regulation and cell adhesion that bind beta-Gal residues in oligosaccharides. Evidence indicates that some of the biological properties of galectins are due to their cross-linking activities with multivalent glycoconjugate receptors. Therefore determination of the quaternary solution structures of these proteins is important in understanding their structure-function properties. The present study reports analytical sedimentation velocity and equilibrium data for galectins-1, -3, and -7 in the absence and presence of bound LacNAc, the natural ligand epitope. Galectin-1 from bovine heart and recombinant human galectin-7 were found to be stable dimers by both methods. In contrast, recombinant murine galectin-3, as well as its proteolytical derived C-terminal domain, are predominantly monomeric. The presence of LacNAc at concentrations sufficient to fully saturate the proteins had no significant effect on either the weight average molecular weight determined by sedimentation equilibrium or the hydrodynamic properties determined from sedimentation velocity experiments. These results show that binding of a monovalent ligand does not affect oligomerization of these galectins.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号