共查询到20条相似文献,搜索用时 15 毫秒
1.
Case-control data on childhood leukemia in Los Angeles County were reanalyzed with residential magnetic fields predicted from the wiring configurations of nearby transmission and distribution lines. As described in a companion paper, the 24-h means of the magnetic field's magnitude in subjects' homes were predicted by a physically based regression model that had been fitted to 24-h measurements and wiring data. In addition, magnetic field exposures were adjusted for the most likely form of exposure assessment errors: classic errors for the 24-h measurements and Berkson errors for the predictions from wire configurations. Although the measured fields had no association with childhood leukemia (P for trend=.88), the risks were significant for predicted magnetic fields above 1.25 mG (odds ratio=2.00, 95% confidence interval=1.03-3.89), and a significant dose-response was seen (P for trend=.02). When exposures were determined by a combination of predictions and measurements that corrects for errors, the odds ratio (odd ratio=2.19, 95% confidence interval=1.12-4.31) and the trend (p =.007) showed somewhat greater significance. These findings support the hypothesis that magnetic fields from electrical lines are causally related to childhood leukemia but that this association has been inconsistent among epidemiologic studies due to different types of exposure assessment error. In these data, the leukemia risks from a child's residential magnetic field exposure appears to be better assessed by wire configurations than by 24-h area measurements. However, the predicted fields only partially account for the effect of the Wertheimer-Leeper wire code in a multivariate analysis and do not completely explain why these wire codes have been so often associated with childhood leukemia. The most plausible explanation for our findings is that the causal factor is another magnetic field exposure metric correlated to both wire code and the field's time-averaged magnitude. 相似文献
2.
A model has been developed that permits assessment of residential exposure to 60-Hz magnetic fields emitted by appliances. It is based on volume- and time-averaging of magnetic-dipole fields. The model enables the contribution of appliances in the total residential exposure to be compared with that of other sources in any residence under study. Calculations based on measurements reported in the literature on 98 appliances revealed that appliances are not a significant source of whole-body exposure, but that they may be the dominant source of exposure of the body's extremities. 相似文献
3.
Residential magnetic and electric fields 总被引:1,自引:0,他引:1
A magnetic flux density (MFD) and electric-field (E-field) data-acquisition system was built for characterizing extremely low-frequency fields in residences. Every 2 min during 24-h periods, MFD and E-field measurements were made in 43 homes in King, Pierce, and Snohomish counties of Washington State. The total electrical energy used in each residence during the 24-h measurement period was also recorded, and maps were drawn to scale of the distribution wiring within 43 m (140 ft) of these homes. Finally, on a separate date, field measurements were made in each home during an epidemiological interview. The results of this study can be summarized as follows: 1) 24-h-average MFD measured at two separate points in the family room were correlated, as were a 24-h-average bedroom measurement and the mean of the two family-room measurements. 2) The 24-h-average family-room MFD and E-field measurements were uncorrelated. 3) The 24-h-average total harmonic distortions of family-room MFD and E-fields were less than about 24% and 7%, respectively. 4) Residential MFD exhibited a definite 24-h (diurnal) cycle. 5) The 24-h-average and interviewer-measured MFD were correlated. 6) Residential 24-h-average MFD were correlated with the wiring code developed by Wertheimer and Leeper. 7) An improved prediction of 24-h-average residential MFD was obtained using the total number of service drops, the distance to neighboring transmission lines, and the number of primary phase conductors. 相似文献
4.
Cristina Del Seppia Sergio Ghione Paolo Luschi Floriano Papi 《Bioelectromagnetics》1995,16(5):290-294
The comparison of two measurements of the pigeon threshold for electrical stimuli, performed 2 h apart, reveals stress-induced analgesia as a result of stressful manipulations between the two tests. When pigeons are exposed to a weak, oscillating magnetic field between the two measurements, the analgesic response is inhibited and a hyperalgesic effect is recorded. The present findings are in agreement with previous studies showing that magnetic treatments may alter pigeons' emotional state and some of their behavioral patterns. © 1995 Wiley-Liss, Inc. 相似文献
5.
Use of wiring configuration and wiring codes for estimating externally generated electric and magnetic fields 总被引:2,自引:0,他引:2
The relative locations and characteristics of the distribution lines feeding 434 residences in the Denver metropolitan area were recorded and classified according to the Wertheimer-Leeper code (WL code) as a part of an epidemiological study of the incidence of childhood cancer. The WL code was found to place the mean values of the fields in rank order. However, the standard deviations were approximately the same size as the means. Theoretical calculations indicate that a significant fraction of the low-power magnetic fields can be generated by the distribution lines, especially in the cases where the distribution lines are within 50 feet of the residence. Thus, the wiring code was shown to be a useful method for making a first-order approximation to predict long-term, low-level magnetic fields in residences. 相似文献
6.
The relationship of measured residential magnetic fields and wire codes to pregnancy outcome was examined in data collected for a study of childhood cancer in Denver. Pregnancies in homes with measured fields above 0.2 μT or high wire codes were not more likely to end in miscarriage, low birth weight, or preterm delivery. Lack of data on potential confounders and small numbers of cases limit the study's conclusions. © 1994 Wiley-Liss, Inc. 相似文献
7.
8.
To evaluate the effects of extremely low frequency magnetic field (ELFMF) on beta-cell survival and function, we cultured a hamster-derived insulin-secreting cell line (HIT-T15), which exhibits responsiveness to glucose in a semi-physiological range, under exposure to sham and ELFMF conditions, and assessed cell survival and function. We used our previously developed ELFMF exposure unit (a sinusoidal magnetic field at a frequency of 60 Hz, 5 mT) to culture cells under exposure to ELFMF conditions. We found that exposure to ELFMF for 5 days in the absence of glucose increased cell number, exposure for 2 days in the absence of glucose and for 5 days with 100 mg/dl glucose increased the insulin secretion to the culture medium, and exposure for 2 and 5 days with 40 and 100 mg/dl glucose increased intracellular insulin concentration in HIT-T15 cells. The increase in cell number under apoptotic culture conditions by exposure to ELFMF could lead to new therapeutic concepts in the treatment of diabetes. The ELFMF-induced increase in intracellular insulin concentration could be utilized to develop culture conditions to enhance intracellular insulin concentration in insulin-secreting cells that would be useful for cell transplantation to cure diabetes mellitus. 相似文献
9.
Floriano Papi Sergio Ghione Caterina Rosa Cristina Del Seppia Paolo Luschi 《Bioelectromagnetics》1995,16(5):295-300
To assess the effect of a magnetic treatment on pain perception, we compared the sensory threshold in 18 healthy volunteers. We determined the threshold by noninvasive electrical stimulation of the tooth pulp and skin before and after exposure to an altered magnetic field of low intensity and to a sham treatment. Five different parameters were recorded: the sensory and pain thresholds for the tooth and the sensory, pain, and tolerance thresholds for the skin. Two hours of exposure to a weak, oscillating magnetic field induced a significant decrease in three parameters (dental sensory and cutaneous pain and tolerance thresholds), whereas the other two parameters showed a similar tendency. When the same subjects were exposed to a sham treatment, only marginal, nonsignificant variations in all parameters were observed. These results represent the first piece of evidence that weak alterations of the magnetic field may induce hyperalgesia in humans. © 1995 Wiley-Liss, Inc. 相似文献
10.
Spatial configurations of polynucleotide chains. I. Steric interactions in polyribonucleotides: a virtual bond model 总被引:5,自引:0,他引:5
A simplified scheme for treating the spatial configurations of polynucleotide chains is developed using the rotational isomeric state approximation and statistical methods applicable to linear systems of interacting subunits. As a consequence of geometric constraints imposed by the skeletal structure and of the severity of certain steric interactions, it is possible to represent the repeat unit comprising six skeletal bonds by two virtual bonds of fixed length. The configuration of the polynucleotide chain as a whole may be conveniently described by an alternating succession of these two virtual bonds. Moreover, analysis of steric interactions suggests that bond rotations governing the mutual orientation of a given pair of successive virtual bonds should be sensibly independent of the rotations affecting the mutual orientation of other pairs. The statistical mechanical treatment of configuration-dependent properties is much simplified in consequence of this mutual independence. Mean-square dimensions calculated by giving equal weights to all sterically allowed conformations are much smaller than values determined by Felsenfeld and co-workers. The calculated dimensions are markedly increased, however, by placing certain arbitrary restrictions on the rotations about selected pairs of skeletal bonds. It is thus demonstrated that steric interactions alone are insufficient to account for the spatial characteristics of polynucleotide chains. The dimensions are also found to be sensitive to the conformation of the ribose ring of each nucleotide unit, but, insofar as the influences of steric interactions are concerned, the dimensions do not depend on the heterocyclic base attached to the ribose ring. 相似文献
11.
Paniagua JM Jiménez A Rufo M Gutiérrez JA Gómez FJ Antolín A 《Radiation and environmental biophysics》2007,46(1):69-76
Magnetic field levels were studied in an urban area—the city of Cáceres (Spain). The study included systematic spot measurements
throughout the city, an analysis of the temporal variation of the magnetic field, and the incorporation of the data into a
geographic information system. The levels detected were at most 7.3% of the ICNIRP reference levels, and the highest fields
were found in the oldest neighborhoods. Considered overall, the ELF magnetic flux density levels determined in the present
study were between those found in residential and in working environments. Knowledge of the levels of such fields in urban
areas is therefore fundamental in evaluating the population’s overall exposure, especially for people who work outdoors. 相似文献
12.
This study assessed exposure to extremely low frequency (ELF) magnetic fields of welders and other metal workers and compared exposure from different welding processes. Exposure to ELF magnetic fields was measured for 50 workers selected from a nationwide cohort of metal workers and 15 nonrandomly selected full-time welders in a shipyard. The measurements were carried out with personal exposure meters during 3 days of work for the metal workers and 1 day of work for the shipyard welders. To record a large dynamic range of ELF magnetic field values, the measurements were carried out with “high/low” pairs of personal exposure meters. Additional measurements of static magnetic fields at fixed positions close to welding installations were done with a Hall-effect fluxmeter. The total time of measurement was 1273 hours. The metal workers reported welding activity for 5.8% of the time, and the median of the work-period mean exposure to ELF magnetic fields was 0.18 μT. DC metal inert or active gas welding (MIG/MAG) was used 80% of the time for welding, and AC manual metal arc welding (MMA) was used 10% of the time. The shipyard welders reported welding activity for 56% of the time, and the median and maximum of the workday mean exposure to ELF magnetic fields was 4.70 and 27.5 μT, respectively. For full-shift welders the average workday mean was 21.2 μT for MMA welders and 2.3 μT for MIG/MAG welders. The average exposure during the effective time of welding was estimated to be 65 μT for the MMA welding process and 7 μT for the MIG/MAG welding process. The time of exposure above 1 μT was found to be a useful measure of the effective time of welding. Large differences in exposure to ELF magnetic fields were found between different groups of welders, depending on the welding process and effective time of welding. MMA (AC) welding caused roughly 10 times higher exposure to ELF magnetic fields compared with MIG/MAG (DC) welding. The measurements of static fields suggest that the combined exposure to static and ELF fields of MIG/MAG (DC) welders and the exposure to ELF fields of MMA (AC) welders are roughly of the same level. Bioelectromagnetics 18:470–477, 1997. © 1997 Wiley-Liss, Inc. 相似文献
13.
14.
Cardiac tissue can be considered macroscopically as a bidomain, anisotropic conductor in which simple depolarization wavefronts produce complex current distributions. Since such distributions may be difficult to measure using electrical techniques, we have developed a mathematical model to determine the feasibility of magnetic localization of these currents. By applying the finite element method to an idealized two-dimensional bisyncytium with anisotropic conductivities, we have calculated the intracellular and extracellular potentials, the current distributions, and the magnetic fields for a circular depolarization wavefront. The calculated magnetic field 1 mm from the tissue is well within the sensitivity of a SQUID magnetometer. Our results show that complex bisyncytial current patterns can be studied magnetically, and these studies should provide valuable insight regarding the electrical anisotropy of cardiac tissue. 相似文献
15.
Exposure of maize seeds to stationary magnetic fields: Effects on germination and early growth 总被引:1,自引:0,他引:1
《Environmental and Experimental Botany》2007,59(1):68-75
The effect of the exposure of maize seeds to stationary magnetic fields on germination and early growth has been studied under laboratory conditions. Seeds were magnetically exposed to one of two magnetic field strengths, 125 or 250 mT for different periods of time. Mean germination time and the time required to obtain 10, 25, 50, 75 and 90% of seeds to germinate were calculated. The results showed a reduction of these parameters for most of magnetic treatments, therefore their rate of germination was increased.Growth data measured on the 7th and 10th day after seeding allowed us to corroborate the effect observed in germination tests. Treated plants grew higher and heavier than control; on the 10th day total length was greater than control plants exposed to stationary magnetic field, corresponding with increase of the total fresh weight. The greatest increases were obtained for plants continuously exposed to 125 or 250 mT. 相似文献
16.
17.
There has been a significant controversy over the past decade regarding the relative information content of bioelectric and biomagnetic signals. In this paper we present a new, theoretical example of an electrically-silent magnetic field, based on a bidomain model of a cylindrical strand of tissue generalized to include off-diagonal components in the conductivity tensors. The physical interpretation of the off-diagonal components is explained, and analytic expressions for the electrical potential and the magnetic field are found. These expressions show that information not obtainable from electrical potential measurements can be obtained from measurements of the magnetic field in systems with conductivity tensors more complicated than those previously examined. 相似文献
18.
19.
The effects of exposure to clinical magnetic resonance imaging (MRI) on analgesia induced by the mu opiate agonist, fentanyl, was examined in mice. During the dark period, adult male mice were exposed for 23.2 min to the time-varying (0.6 T/sec) magnetic field (TVMF) component of the MRI procedure. Following this exposure, the analgesic potency of fentanyl citrate (0.1 mg/kg) was determined at 5, 10, 15, and 30 min post-injection, using a thermal test stimulus (hot-plate 50 degrees C). Exposure to the magnetic-field gradients attenuated the fentanyl-induced analgesia in a manner comparable to that previously observed with morphine. These results indicate that the time-varying magnetic fields associated with MRI have significant inhibitory effects on the analgesic effects of specific mu-opiate-directed ligands. 相似文献
20.
Exposure to strong ELF magnetic fields does not alter cardiac autonomic control mechanisms 总被引:3,自引:0,他引:3
Clinical and epidemiological studies attest that alterations in heart rate variability (HRV) are predictive of specific types of cardiovascular morbidity and mortality in otherwise healthy persons. Recent reports also suggest that changes in HRV may be associated with exposure to intermittent magnetic fields (60 Hz, 28.3 microT) in the laboratory and that mortality is increased in cardiac disease categories related to altered HRV for utility workers whose jobs involve longer exposure to elevated magnetic fields. This study combined three approaches to learn more about the specific exposure circumstances under which changes in HRV occur. First, cardiac autonomic control, as indexed by HRV spectral analysis measures, was measured in 24 men during exposure to a much higher intensity field than any previously examined (resultant flux density = 127.3 microT [1273 milliGauss, mG]). Second, HRV measures from the same individual were compared across three relevant test conditions: intermittent and continuous field exposure and during a no-exposure, control condition. Third, electrocardiographic data were analyzed to determine if the precise timing of when the magnetic field switched on or off in relation to the cardiac cycle results in phase-resetting of the human cardiac rhythm. HRV measures were not altered by either field exposure condition compared to the control condition, and no evidence for a phase-resetting mechanism was found. Further research is needed to resolve the differences between the present and the earlier laboratory-based studies of HRV and to determine if cardiac rhythm disturbances are associated with exposure to the more complex magnetic fields found in the man-made environment. 相似文献