首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
X-ray computed tomography (XCT) has been shown to be an effective imaging technique for a variety of materials. Due to the relatively low differential attenuation of X-rays in biological tissue, a high density contrast agent is often required to obtain optimal contrast. The contrast agent, iodine potassium iodide (), has been used in several biological studies to augment the use of XCT scanning. Recently was used in XCT scans of animal hearts to study cardiac structure and to generate 3D anatomical computer models. However, to date there has been no thorough study into the optimal use of as a contrast agent in cardiac muscle with respect to the staining times required, which has been shown to impact significantly upon the quality of results. In this study we address this issue by systematically scanning samples at various stages of the staining process. To achieve this, mouse hearts were stained for up to 58 hours and scanned at regular intervals of 6–7 hours throughout this process. Optimal staining was found to depend upon the thickness of the tissue; a simple empirical exponential relationship was derived to allow calculation of the required staining time for cardiac samples of an arbitrary size.  相似文献   

2.
3.
In practical applications of computed tomography imaging (CT), it is often the case that the set of projection data is incomplete owing to the physical conditions of the data acquisition process. On the other hand, the high radiation dose imposed on patients is also undesired. These issues demand that high quality CT images can be reconstructed from limited projection data. For this reason, iterative methods of image reconstruction have become a topic of increased research interest. Several algorithms have been proposed for few-view CT. We consider that the accurate solution of the reconstruction problem also depends on the system matrix that simulates the scanning process. In this work, we analyze the application of the Siddon method to generate elements of the matrix and we present results based on real projection data.  相似文献   

4.

Objectives

Typical streak artifacts known as metal artifacts occur in the presence of strongly attenuating materials in computed tomography (CT). Recently, vendors have started offering metal artifact reduction (MAR) techniques. In addition, a MAR technique called the metal deletion technique (MDT) is freely available and able to reduce metal artifacts using reconstructed images. Although a comparison of the MDT to other MAR techniques exists, a comparison of commercially available MAR techniques is lacking. The aim of this study was therefore to quantify the difference in effectiveness of the currently available MAR techniques of different scanners and the MDT technique.

Materials and Methods

Three vendors were asked to use their preferential CT scanner for applying their MAR techniques. The scans were performed on a Philips Brilliance ICT 256 (S1), a GE Discovery CT 750 HD (S2) and a Siemens Somatom Definition AS Open (S3). The scans were made using an anthropomorphic head and neck phantom (Kyoto Kagaku, Japan). Three amalgam dental implants were constructed and inserted between the phantom’s teeth. The average absolute error (AAE) was calculated for all reconstructions in the proximity of the amalgam implants.

Results

The commercial techniques reduced the AAE by 22.0±1.6%, 16.2±2.6% and 3.3±0.7% for S1 to S3 respectively. After applying the MDT to uncorrected scans of each scanner the AAE was reduced by 26.1±2.3%, 27.9±1.0% and 28.8±0.5% respectively. The difference in efficiency between the commercial techniques and the MDT was statistically significant for S2 (p=0.004) and S3 (p<0.001), but not for S1 (p=0.63).

Conclusions

The effectiveness of MAR differs between vendors. S1 performed slightly better than S2 and both performed better than S3. Furthermore, for our phantom and outcome measure the MDT was more effective than the commercial MAR technique on all scanners.  相似文献   

5.
Nanostructured three-dimensional constructs combining layer-by-layer technology (LbL) and template leaching were processed and evaluated as possible support structures for cartilage tissue engineering. Multilayered constructs were formed by depositing the polyelectrolytes chitosan (CHT) and chondroitin sulphate (CS) on either bidimensional glass surfaces or 3D packet of paraffin spheres. 2D CHT/CS multi-layered constructs proved to support the attachment and proliferation of bovine chondrocytes (BCH). The technology was transposed to 3D level and CHT/CS multi-layered hierarchical scaffolds were retrieved after paraffin leaching. The obtained nanostructured 3D constructs had a high porosity and water uptake capacity of about 300%. Dynamical mechanical analysis (DMA) showed the viscoelastic nature of the scaffolds. Cellular tests were performed with the culture of BCH and multipotent bone marrow derived stromal cells (hMSCs) up to 21 days in chondrogenic differentiation media. Together with scanning electronic microscopy analysis, viability tests and DNA quantification, our results clearly showed that cells attached, proliferated and were metabolically active over the entire scaffold. Cartilaginous extracellular matrix (ECM) formation was further assessed and results showed that GAG secretion occurred indicating the maintenance of the chondrogenic phenotype and the chondrogenic differentiation of hMSCs.  相似文献   

6.
The purpose of this study was twofold: (1) to develop multiple regression equations for predicting computed tomography (CT) derived intra-abdominal (IAF), subcutaneous (SCF), and total (TOTF= IAF+SCF) abdominal adipose tissue areas from anthropometric measures in adult white males with a large range of age (18–71 years) and percent body fat (2.0–40.6); and (2) to validate the new and existing equations that used similar Hounsfield Units (HU) for determining IAF for estimating these fat depots. One hundred fifty-one white male subjects had IAF, SCF, and TOTF determined by a single CT scan, skinfold and circumference measures taken and body density determined. Linear intra-correlations and factor analysis procedures were used to identify variables for inclusion in stepwise multiple regression solutions. IAF was estimated from age, waist circumference, the sum of mid-thigh and lower thigh circumferences, and vertical abdominal skinfold. SCF was estimated from age, umbilicus circumference, chest and suprailiac skinfolds. TOTF was estimated from age, body mass index (BMI), chest skinfold, and umbilicus circumference. R2 for IAF, SCF, and TOTF was .73, .77, and .86 respectively. The existing and the new equations were validated on an independent sub-sample of 51 subjects. The only existing equation that met validation criteria had a validation R2 = .67 for IAF. All three new equations met validation criteria with R 2 validations of .75, .79, and .85 for IAF, SCF, and TOTF respectively. It is concluded that the new equations might be used as an inexpensive estimation of IAF, SCF, and TOTF in adult white males varying greatly in age and percent body fat.  相似文献   

7.
ObjectiveOur aim was to assess renal function using as laboratory measurements serum creatinine and cystatin C concentrations before and after administration of low-osmolarity (nonionic) iodinated contrast medium in patients with cancer undergoing computed tomography (CT).MethodsThis prospective study included 400 oncologic outpatients. Serum creatinine and cystatin C concentrations were measured before and 72 h after contrast administration. Glomerular filtration rates (GFRs) were estimated using serum creatinine–based [Modification of Diet in Renal Disease (MDRD) and Cockroft-Gault and cystatin C based (Larsson) equations. Exploratory data analysis was performed. The nonparametric Wilcoxon test was used to compare pre and post contrast of test results and estimated clearance. The confidence interval used in the analysis was 95%.ResultsCompared with the pre-contrast values, the mean serum creatinine concentration was significantly higher and average GFRs estimated using MDRD and Cockcroft-Gault equations were significantly lower after the administration of contrast (p <0.001). It was also observed a significant increase after contrast in the concentration of Cystatin C (p = 0.015). In addition, a decrease in GFR estimated using the average Larsson (p = 0.021) was observed between time points. However, none of the patients presented clinically significant nephropathy.ConclusionsAssessment using serum creatinine and cystatin C concentrations showed changes in renal function among patients with cancer undergoing contrast-enhanced CT examination in this study. No significant renal damage related to the use of low-osmolarity iodinated contrast medium of the type and dosage employed in this study was observed. This contrast medium is thus safe for use in patients with cancer.  相似文献   

8.
目的 生物电磁学参数中的电导率与组织的功能性信息直接相关,精准重建生物组织电导率在医学成像技术和医学诊断领域中有着重要意义。本文改进定量微波热声层析成像(microwave-induced thermoacoustic tomography,MTAT)算法,使组织电导率的重建精度提高。方法 本文在利用有限元离散法求解热声波动方程和亥姆霍兹方程的基础之上,提出了一种基于正则化牛顿迭代法(regularized Newton iteration method,RNIM)定量重建组织电导率的改进方法。结果 通过数值模拟实验和含不同浓度NaCl溶液的仿体实验,验证了算法改进的有效性。组织仿体实验结果表明,目标在不同位置、不同大小、不同对比度情况下,相比于定量微波热声层析成像采用拟合(fitting)的方法,采用正则化牛顿法定量重建的仿体电导率相对误差明显降低,重建目标精度提高。在仿体实验中采用RNIM方法重建相同浓度的单目标在不同位置的电导率变化幅度更小,以及重建多目标电导率的相对比值与实际更接近,实验结果验证了改进方法的稳定性。结论 研究结果表明优化算法能更加准确地定量重建组织仿体的电导率,...  相似文献   

9.
Due to its high spatial resolution, synchrotron radiation x-ray nano-scale computed tomography (nano-CT) is sensitive to misalignments in scanning geometry, which occurs quite frequently because of mechanical errors in manufacturing and assembly or from thermal expansion during the time-consuming scanning. Misalignments degrade the imaging results by imposing artifacts on the nano-CT slices. In this paper, the geometric misalignment of the synchrotron radiation nano-CT has been analyzed by partial derivatives on the CT reconstruction algorithm and a correction method, based on cross correlation and least-square sinusoidal fitting, has been reported. This work comprises a numerical study of the method and its experimental verification using a dataset measured with the full-field transmission x-ray microscope nano-CT at the beamline 4W1A of the Beijing Synchrotron Radiation Facility. The numerical and experimental results have demonstrated the validity of the proposed approach. It can be applied for dynamic geometric misalignment and needs neither phantom nor additional correction scanning. We expect that this method will simplify the experimental operation of synchrotron radiation nano-CT.  相似文献   

10.

Background & Aims

The amount of drug-loaded lipiodol in an HCC tumor post-transarterial chemoembolization (TACE) correlates with the risk of local tumor recurrence. Lipiodol enhancement of a tumor on conventional CT, measured in Hounsfield units (HU), can predict tumor response. Here we investigate whether cone-beam CT (CBCT) can also be used to predict tumor response, providing the benefit of being able to optimize the patient’s treatment plan intra-procedurally.

Methods

A total of 82 HCC nodules (82 patients), ≤5 cm in diameter, were treated with balloon-occluded TACE using miriplatin between December 2013 and November 2014. For each patient, both CBCT and conventional CT images were obtained post-TACE. The degree of correlation between CBCT and conventional CT was determined by comparing identical regions of interest for each imaging modality using pixel values.

Results

The pixel values from conventional CT and CBCT were highly correlated, with a Pearson correlation coefficient of 0.912 (p<0.001). The location of the nodules within the liver did not affect the results; the correlation coefficient was 0.891 (p<0.001) for the left lobe and 0.926 (p<0.001) for the right lobe. The mean pixel value for conventional CT was 439 ± 279 HU, and the mean pixel value for CBCT was 416 ± 311 HU.

Conclusions

CBCT may be used as a substitute for conventional CT to quantitatively evaluate the amount of drug-loaded lipiodol within an HCC nodule and, hence, the efficacy of TACE treatment. The major benefit of using CBCT is the ability to predict the likelihood of local recurrence intra-procedurally, enabling subsequent treatment optimization.  相似文献   

11.

Objective

To ascertain accurate measurements of, and the relationships between, the normative parameters of the tracheobronchial trees in the Chinese population using multi-slice spiral computed tomography (CT) and multi-planar reconstruction (MPR).

Materials and Methods

Measurements were performed on 2107 patients who underwent thoracic CT scans in the PLA General Hospital. The lengths of the trachea and the main stem bronchi, and the sizes of the subcarinal angle were obtained through CT or MPR imaging. Multi-variance analyses were performed to detect potential correlations between obtained parameters.

Results

The mean length of the trachea was 104.9 ± 13.4 mm (107.8 ± 13.2 mm for men and 101.4 ± 12.8 mm for women). The mean lengths of the right and left main stem bronchi were 13.6 ± 4.3 and 48.3 ± 6.5 mm, respectively. The right bronchus angle and the left bronchus angle were 34.9 and 42.5 degrees, respectively. Significant gender differences were found in all the parameters measured except for the angle of the right upper lobe bronchus. There are no statistically significant correlations among these parameters.

Conclusions

The normal reference values and the likely ranges of distribution of the tracheobronchial trees in the Chinese population have been established. Significant gender differences exist in the dimensions of the trachea, with the exception of the Right upper bronchial angle (RUA).  相似文献   

12.
To retrospectively determine the association between breast lesion morphology and malignancy and to determine the optimal value of lesion enhancement (HU, Hounsfield units) to improve the diagnostic accuracy of breast cancer in patients with incidental breast lesions (IBLs). A total of 97 patients with 102 IBLs detected from July 2009 to December 2012 were enrolled in this study. Two radiologists analyzed CT images for the presence of malignancy based on the morphology of the lesions alone and in combination with an enhancement value (HU) analysis. There were 36 malignant and 66 benign IBLs. When the morphology and enhancement values were combined, the sensitivity, specificity, and accuracy were 92%, 97%, and 95%, respectively, for reader 1 and 89%, 94%, and 92%, respectively, for reader 2. The addition of HU values led to correct changes in the diagnosis; specifically, the accuracy of the diagnosis of reader 1 and reader 2 improved by 6.9% and 11.8%, respectively. The addition of the enhancement value (HU) to the CT morphology improved the diagnostic accuracy in the differentiation of malignant from benign IBLs by using the region of interest (ROI) to measure the HU within the most suspicious part of the lesion.  相似文献   

13.
Preclinical xenograft models have contributed to advancing our understanding of the molecular basis of prostate cancer and to the development of targeted therapy. However, traditional preclinical in vivo techniques using caliper measurements and survival analysis evaluate the macroscopic tumor behavior, whereas tissue sampling disrupts the microenvironment and cannot be used for longitudinal studies in the same animal. Herein, we present an in vivo study of [18F]-fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) designed to evaluate the metabolism within the microenvironment of LAPC4-CR, a unique murine model of castration-resistant prostate cancer. Mice bearing LAPC4-CR subcutaneous tumors were administered [18F]-FDG via intravenous injection. After a 60-minute distribution phase, the mice were imaged on a PET/CT scanner with submillimeter resolution; and the fused PET/CT images were analyzed to evaluate tumor size, location, and metabolism across the cohort of mice. The xenograft tumors showed [18F]-FDG uptake that was independent of tumor size and was significantly greater than uptake in skeletal muscle and liver in mice (Wilcoxon signed-rank P values of .0002 and .0002, respectively). [18F]-FDG metabolism of the LAPC4-CR tumors was 2.1 ± 0.8 ID/cm3*wt, with tumor to muscle ratio of 7.4 ± 4.7 and tumor to liver background ratio of 6.7 ± 2.3. Noninvasive molecular imaging techniques such as PET/CT can be used to probe the microenvironment of tumors in vivo. This study showed that [18F]-FDG-PET/CT could be used to image and assess glucose metabolism of LAPC4-CR xenografts in vivo. Further work can investigate the use of PET/CT to quantify the metabolic response of LAPC4-CR to novel agents and combination therapies using soft tissue and possibly bone compartment xenograft models.  相似文献   

14.
目的:对直接影响神经支架微观结构的关键因素进行分析,以确定制备不同孔径仿真支架的制备工艺。方法:用前期开发的神经支架制备工艺,应用不同浓度的醋酸浓度和冷淋速度制备仿真神经支架,以扫描电镜观察神经支架结构特征,以确定醋酸浓度和冷淋速度对神经支架内部结构的影响。结果:醋酸浓度和冷淋速度对神经支架内部结构具有重要影响。醋酸浓度为0mg/ml时,无法制备定向结构的神经支架,当醋酸浓度为1mg/ml、2mg/ml、3mg/ml和4mg/ml时,可制备轴定向仿真支架,并且神经支架的孔径随醋酸浓度增大而增大;当冷淋速度为1×10-5m/s、2×10-5m/s和5×10-5m/s时,所制备的仿真支架内部均呈明显的轴向微管结构,其中冷淋速度为2×10-5m/s时,其轴向微管结构排列最为有序、规律。当速度为1×10-6m/s,2×10-6m/s,5×10-6m/s以及1×10-4m/s时,所制备的材料内部微管结构走向无明显规律。结论:醋酸浓度和冷淋速度是影响神经支架内部结构的两个关键因素,通过改变醋酸浓度和冷淋速度可制备不同孔径的仿真神经支架。  相似文献   

15.
目的:对直接影响神经支架微观结构的关键因素进行分析,以确定制备不同孔径仿真支架的制备工艺。方法:用前期开发的神经支架制备工艺,应用不同浓度的醋酸浓度和冷淋速度制备仿真神经支架,以扫描电镜观察神经支架结构特征,以确定醋酸浓度和冷淋速度对神经支架内部结构的影响。结果:醋酸浓度和冷淋速度对神经支架内部结构具有重要影响。醋酸浓度为0mg/ml时,无法制备定向结构的神经支架,当醋酸浓度为1mg/ml、2mg/ml、3mg/ml和4mg/ml时,可制备轴定向仿真支架,并且神经支架的孔径随醋酸浓度增大而增大;当冷淋速度为1×10-5m/s、2×10-5m/s和5×10-5m/s时,所制备的仿真支架内部均呈明显的轴向微管结构,其中冷淋速度为2×10-5m/s时,其轴向微管结构排列最为有序、规律。当速度为1×10-6m/s,2×10-6m/s,5×10-6m/s以及1×10-4m/s时,所制备的材料内部微管结构走向无明显规律。结论:醋酸浓度和冷淋速度是影响神经支架内部结构的两个关键因素,通过改变醋酸浓度和冷淋速度可制备不同孔径的仿真神经支架。  相似文献   

16.
Collagen content and organization in developing collagenous tissues can be influenced by local tissue strains and tissue constraint. Tissue engineers aim to use these principles to create tissues with predefined collagen architectures. A full understanding of the exact underlying processes of collagen remodeling to control the final tissue architecture, however, is lacking. In particular, little is known about the (re)orientation of collagen fibers in response to changes in tissue mechanical loading conditions. We developed an in vitro model system, consisting of biaxially-constrained myofibroblast-seeded fibrin constructs, to further elucidate collagen (re)orientation in response to i) reverting biaxial to uniaxial static loading conditions and ii) cyclic uniaxial loading of the biaxially-constrained constructs before and after a change in loading direction, with use of the Flexcell FX4000T loading device. Time-lapse confocal imaging is used to visualize collagen (re)orientation in a nondestructive manner.Cell and collagen organization in the constructs can be visualized in real-time, and an internal reference system allows us to relocate cells and collagen structures for time-lapse analysis. Various aspects of the model system can be adjusted, like cell source or use of healthy and diseased cells. Additives can be used to further elucidate mechanisms underlying collagen remodeling, by for example adding MMPs or blocking integrins. Shape and size of the construct can be easily adapted to specific needs, resulting in a highly tunable model system to study cell and collagen (re)organization.  相似文献   

17.

Background

Factors determining the shape of the human rib cage are not completely understood. We aimed to quantify the contribution of anthropometric and COPD-related changes to rib cage variability in adult cigarette smokers.

Methods

Rib cage diameters and areas (calculated from the inner surface of the rib cage) in 816 smokers with or without COPD, were evaluated at three anatomical levels using computed tomography (CT). CTs were analyzed with software, which allows quantification of total emphysema (emphysema%). The relationship between rib cage measurements and anthropometric factors, lung function indices, and %emphysema were tested using linear regression models.

Results

A model that included gender, age, BMI, emphysema%, forced expiratory volume in one second (FEV1)%, and forced vital capacity (FVC)% fit best with the rib cage measurements (R2 = 64% for the rib cage area variation at the lower anatomical level). Gender had the biggest impact on rib cage diameter and area (105.3 cm2; 95% CI: 111.7 to 98.8 for male lower area). Emphysema% was responsible for an increase in size of upper and middle CT areas (up to 5.4 cm2; 95% CI: 3.0 to 7.8 for an emphysema increase of 5%). Lower rib cage areas decreased as FVC% decreased (5.1 cm2; 95% CI: 2.5 to 7.6 for 10 percentage points of FVC variation).

Conclusions

This study demonstrates that simple CT measurements can predict rib cage morphometric variability and also highlight relationships between rib cage morphometry and emphysema.  相似文献   

18.
目的:评价多层螺旋CT对胃癌术前分期的准确性.方法:对78例经胃镜活捡证实为胃癌的患者进行MSCT增强扫描,其中67例经历了手术治疗,并获得术后病理结果.由两位资深放射科医师对影像学资料进行分析,轴位和MPR影像用于术前TNM分期,N分期分别采用UICCTNM分期和日本分期,两种分期的准确性比较采用McNemar检验进行统计学分析.结果:轴位和轴位结合MPR影像的总体T分期准确率分别为67%(45/67)和78%(52/67)(P<0.05),总体N分期的准确率分别是61%(41/67)和67%(45/67)(P>0.05,日本分期),54%(36/67)和60%(40/67)(P>0.05,UICC TNM分期),总体M分期准确率为93%(73/78).结论:服水低张动态增强MSCT对胃癌术前TNM分期具有很高的准确性,MPR能提高胃癌T分期的准确率,但不能提高N分期的准确率.  相似文献   

19.

Purpose

Evaluation of a new software tool for generation of simulated low-dose computed tomography (CT) images from an original higher dose scan.

Materials and Methods

Original CT scan data (100 mAs, 80 mAs, 60 mAs, 40 mAs, 20 mAs, 10 mAs; 100 kV) of a swine were acquired (approved by the regional governmental commission for animal protection). Simulations of CT acquisition with a lower dose (simulated 10–80 mAs) were calculated using a low-dose simulation algorithm. The simulations were compared to the originals of the same dose level with regard to density values and image noise. Four radiologists assessed the realistic visual appearance of the simulated images.

Results

Image characteristics of simulated low dose scans were similar to the originals. Mean overall discrepancy of image noise and CT values was −1.2% (range −9% to 3.2%) and −0.2% (range −8.2% to 3.2%), respectively, p>0.05. Confidence intervals of discrepancies ranged between 0.9–10.2 HU (noise) and 1.9–13.4 HU (CT values), without significant differences (p>0.05). Subjective observer evaluation of image appearance showed no visually detectable difference.

Conclusion

Simulated low dose images showed excellent agreement with the originals concerning image noise, CT density values, and subjective assessment of the visual appearance of the simulated images. An authentic low-dose simulation opens up opportunity with regard to staff education, protocol optimization and introduction of new techniques.  相似文献   

20.