首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
Copy number changes and CpG methylation of various genes are hallmarks of tumor development but are not yet widely used in diagnostic settings. The recently developed multiplex ligation-dependent probe amplification (MLPA) method has increased the possibilities for multiplex detection of gene copy number aberrations in a routine laboratory. Here we describe a novel robust method: the methylation-specific MLPA (MS-MLPA) that can detect changes in both CpG methylation as well as copy number of up to 40 chromosomal sequences in a simple reaction. In MS-MLPA, the ligation of MLPA probe oligonucleotides is combined with digestion of the genomic DNA–probe hybrid complexes with methylation-sensitive endonucleases. Digestion of the genomic DNA–probe complex, rather than double-stranded genomic DNA, allowed the use of DNA derived from the formalin treated paraffin-embedded tissue samples, enabling retrospective studies. To validate this novel method, we used MS-MLPA to detect aberrant methylation in DNA samples of patients with Prader–Willy syndrome, Angelman syndrome or acute myeloid leukemia.  相似文献   

2.
Succession of ecotypes, physiologically diverse strains with negligible rRNA sequence divergence, may explain the dominance of small, red-pigmented (phycoerythrin-rich) cyanobacteria in the autotrophic picoplankton of deep lakes (C. Postius and A. Ernst, Arch. Microbiol. 172:69–75, 1999). In order to test this hypothesis, it is necessary to determine the abundance of specific ecotypes or genotypes in a mixed background of phylogenetically similar organisms. In this study, we examined the performance of Taq nuclease assays (TNAs), PCR-based assays in which the amount of an amplicon is monitored by hydrolysis of a labeled oligonucleotide (TaqMan probe) when hybridized to the amplicon. High accuracy and a 7-order detection range made the real-time TNA superior to the corresponding end point technique. However, in samples containing mixtures of homologous target sequences, quantification can be biased due to limited specificity of PCR primers and probe oligonucleotides and due to accumulation of amplicons that are not detected by the TaqMan probe. A decrease in reaction efficiency, which can be recognized by direct monitoring of amplification, provides experimental evidence for the presence of such a problem and emphasizes the need for real-time technology in quantitative PCR. Use of specific primers and probes and control of amplification efficiency allow correct quantification of target DNA in the presence of an up to 104-fold excess of phylogenetically similar DNA and of an up to 107-fold excess of dissimilar DNA.  相似文献   

3.
Analytical PCR experiments preferably use internal probes for monitoring the amplification reaction and specific detection of the amplicon. Such internal probes have to be designed in close context with the amplification primers, and may require additional considerations for the detection of genetic variations. Here we describe Edesign, a new online and stand-alone tool for designing sets of PCR primers together with an internal probe for conducting quantitative real-time PCR (qPCR) and genotypic experiments. Edesign can be used for selecting standard DNA oligonucleotides like for instance TaqMan probes, but has been further extended with new functions and enhanced design features for Eprobes. Eprobes, with their single thiazole orange-labelled nucleotide, allow for highly sensitive genotypic assays because of their higher DNA binding affinity as compared to standard DNA oligonucleotides. Using new thermodynamic parameters, Edesign considers unique features of Eprobes during primer and probe design for establishing qPCR experiments and genotyping by melting curve analysis. Additional functions in Edesign allow probe design for effective discrimination between wild-type sequences and genetic variations either using standard DNA oligonucleotides or Eprobes. Edesign can be freely accessed online at http://www.dnaform.com/edesign2/, and the source code is available for download.  相似文献   

4.
To clearly discriminate the results of simultaneous screening and quantification of up to 40 different targets–DNA sequences, long probes from 100 to 500 nt, rather than smaller or similar-sized synthetic ones, were adopted for multiplex ligation-dependent probe amplification (MLPA). To prepare the long probes, asymmetric polymerase chain reaction (PCR) was employed to introduce non-complementary stuffers in between the two parts of the MLPA probe with specially designed primers, then restriction enzymes were selected to digest the double-stranded DNAs, and finally polyacrylamide gel electrophoresis was used to purify the single-stranded DNAs (i.e., the long probes). By using this approach, 12 long probes were prepared and used to identify genetically modified (GM) maize. Our experimental results show that the prepared long probes were in full accordance with the designed ones and could be assembled in 4-, 7-, and 10-plex MLPA analysis without losing result specificity and accuracy, showing they were as effective and reliable in MLPA analysis as those prepared with M13-derived vectors. This novel asymmetric PCR-based approach does not need expensive equipment, special reagents, or complicated operations when compared with previous methods. Therefore, our new approach could make MLPA analysis more independent, efficient, and economical.  相似文献   

5.
To simultaneously analyze mutations and expression levels of multiple genes on one detection platform, we proposed a method termed “multiplex ligation-dependent probe amplification–digital amplification coupled with hydrogel bead-array” (MLPA–DABA) and applied it to diagnose colorectal cancer (CRC). CRC cells and tissues were sampled to extract nucleic acid, perform MLPA with sequence-tagged probes, perform digital emulsion polymerase chain reaction (PCR), and produce a hydrogel bead-array to immobilize beads and form a single bead layer on the array. After hybridization with fluorescent probes, the number of colored beads, which reflects the abundance of expressed genes and the mutation rate, was counted for diagnosis. Only red or green beads occurred on the chips in the mixed samples, indicating the success of single-molecule PCR. When a one-source sample was analyzed using mixed MLPA probes, beads of only one color occurred, suggesting the high specificity of the method in analyzing CRC mutation and gene expression. In gene expression analysis of a CRC tissue from one CRC patient, the mutant percentage was 3.1%, and the expression levels of CRC-related genes were much higher than those of normal tissue. The highly sensitive MLPA–DABA succeeds in the relative quantification of mutations and gene expressions of exfoliated cells in stool samples of CRC patients on the same chip platform. MLPA–DABA coupled with hydrogel bead-array is a promising method in the non-invasive diagnosis of CRC.  相似文献   

6.
Succession of ecotypes, physiologically diverse strains with negligible rRNA sequence divergence, may explain the dominance of small, red-pigmented (phycoerythrin-rich) cyanobacteria in the autotrophic picoplankton of deep lakes (C. Postius and A. Ernst, Arch. Microbiol. 172:69-75, 1999). In order to test this hypothesis, it is necessary to determine the abundance of specific ecotypes or genotypes in a mixed background of phylogenetically similar organisms. In this study, we examined the performance of Taq nuclease assays (TNAs), PCR-based assays in which the amount of an amplicon is monitored by hydrolysis of a labeled oligonucleotide (TaqMan probe) when hybridized to the amplicon. High accuracy and a 7-order detection range made the real-time TNA superior to the corresponding end point technique. However, in samples containing mixtures of homologous target sequences, quantification can be biased due to limited specificity of PCR primers and probe oligonucleotides and due to accumulation of amplicons that are not detected by the TaqMan probe. A decrease in reaction efficiency, which can be recognized by direct monitoring of amplification, provides experimental evidence for the presence of such a problem and emphasizes the need for real-time technology in quantitative PCR. Use of specific primers and probes and control of amplification efficiency allow correct quantification of target DNA in the presence of an up to 10(4)-fold excess of phylogenetically similar DNA and of an up to 10(7)-fold excess of dissimilar DNA.  相似文献   

7.
A sensitive nonisotopic hybridization assay for HIV-1 DNA   总被引:8,自引:0,他引:8  
We have developed a microtiter-based sandwich hybridization assay for the detection of low copy number HIV-1 sequences. The assay employs a capture DNA sequence covalently coupled to microtiter wells through linker arms. The detection probe is a biotin-labeled DNA fragment derived from sequences adjacent to the capture sequence. After hybridization in the presence of sample nucleic acid, the detection probe remains bound only if the sample contained complementary sequences spanning the junction between capture and detection probes. The amount of detection probe bound is quantified by incubation with a peroxidase-streptavidin conjugate and a colorimetric peroxidase substrate. This assay has been combined with enzymatic target amplification to achieve sensitive detection of HIV-1 in patient samples. Following amplification of HIV-1 DNA using the polymerase chain reaction technique, a 190-bp product is produced. This product is easily and specifically quantified using the sandwich hybridization assay. The resulting test can detect one HIV-1-infected cell in 10(5) cells or about 30 molecules of HIV-1 DNA.  相似文献   

8.
Sensitive and specific tests for detecting exogenous DNA molecules are useful for infectious disease diagnosis, gene therapy clinical trial safety, and gene doping surveillance. Taqman real-time PCR using specific sequence probes provides an effective approach to accurately and quantitatively detect exogenous DNA. However, one of the major challenges in these analyses is to eliminate false positive signals caused by either non-targeted exogenous or endogenous DNA sequences, or false negative signals caused by impurities that inhibit PCR. Although multiplex Taqman PCR assays have been applied to address these problems by adding extra primer-probe sets targeted to endogenous DNA sequences, the differences between targets can lead to different detection efficiencies. To avoid these complications, a Taqman PCR-based approach that incorporates an internal threshold control (ITC) has been developed. In this single reaction format, the target sequence and ITC template are co-amplified by the same primers, but are detected by different probes each with a unique fluorescent dye. Sample DNA, a prescribed number of ITC template molecules set near the limit of sensitivity, a single pair of primers, target probe and ITC probe are added to one reaction. Fluorescence emission signals are obtained simultaneously to determine the cycle thresholds (Ct) for amplification of the target and ITC sequences. The comparison of the target Ct with the ITC Ct indicates if a sample is a true positive for the target (i.e. Ct less than or equal to the ITC Ct) or negative (i.e. Ct greater than the ITC Ct). The utility of this approach was demonstrated in a nonhuman primate model of rAAV vector mediated gene doping in vivo and in human genomic DNA spiked with plasmid DNA.  相似文献   

9.
Polymerase chain reaction (PCR) is a sensitive and rapid method for the diagnosis of canine Leishmania infection and can be performed on a variety of biological samples, including peripheral blood, lymph node, bone marrow and skin. Standard PCR requires electrophoretic analysis of the amplification products and is usually not suitable for quantification of the template DNA (unless competitor-based or other methods are developed), being of reduced usefulness when accurate monitoring of target DNA is required. Quantitative real-time PCR allows the continuous monitoring of the accumulation of PCR products during the amplification reaction. This allows the identification of the cycle of near-logarithmic PCR product generation (threshold cycle) and, by inference, the relative quantification of the template DNA present at the start of the reaction. Since the amplification product are monitored in "real-time" as they form cycle-by-cycle, no post-amplification handling is required. The absolute quantification is performed according either to an internal standard co-amplified with the sample DNA, or to an external standard curve obtained by parallel amplification of serial known concentrations of a reference DNA sequence. From the quantification of the template DNA, an estimation of the relative load of parasites in the different samples can be obtained. The advantages compared to standard and semi-quantitative PCR techniques are reduction of the assay's time and contamination risks, and improved sensitivity. As for standard PCR, the minimal components of the quantitative PCR reaction mixture are the DNA target of the amplification, an oligonucleotide primer pair flanking the target sequence, a suitable DNA polymerase, deoxynucleotides, buffer and salts. Different technologies have been set up for the monitoring of amplification products, generally based on the use of fluorescent probes. For instance, SYBR Green technology is a non-specific detection system based on a fluorescent dsDNA intercalator and it is applicable to all potential targets. TaqMan technology is more specific since performs the direct assessment of the amount of amplified DNA using a fluorescent probe specific for the target sequence flanked by the primer pair. This probe is an oligonucleotide labelled with a reporter dye (fluorescent) and a quencher (which absorbs the fluorescent signal generated by the reporter). The thermic protocol of amplification allows the binding of the fluorescent probe to the target sequence before the binding of the primers and the starting of the polymerization by Taq polymerase. During polymerization, 5'-3' exonuclease activity of Taq polymerase digests the probe and in this way the reporter dye is released from the probe and a fluorescent signal is detected. The intensity of the signal accumulates at the end of each cycle and is related to the amount of the amplification product. In recent years, quantitative PCR methods based either on SYBR Green or TaqMan technology have been set up for the quantification of Leishmania in mouse liver, mouse skin and human peripheral blood, targeting either single-copy chromosomal or multi-copy minicircle sequences with high sensitivity and reproducibility. In particular, real-time PCR seems to be a reliable, rapid and noninvasive method for the diagnosis and follow up of visceral leishmaniasis in humans. At present, the application of real-time PCR for research and clinical diagnosis of Leishmania infection in dogs is still foreseable. As for standard PCR, the high sensitivity of real-time PCR could allow the use of blood sampling that is less invasive and easily performed for monitoring the status of the dogs. The development of a real-time PCR assay for Leishmania infantum infection in dogs could support the standard and optimized serological and PCR methods currenly in use for the diagnosis and follow-up of canine leishmaniasis, and perhaps prediction of recurrences associated with tissue loads of residual pathogens after treatment. At this regard, a TaqMan Real Time PCR method developed for the quantification of Leishmania infantum minicircle DNA in peripheral blood of naturally infected dogs sampled before and at different time points after the beginning of a standard antileishmanial therapy will be illustrated.  相似文献   

10.
Abstract

We report the first use of exciplex-based split-probes for detection of the wild type and *3 mutant alleles of human cytochrome P450 2C9. A tandem 8-mer split DNA oligonucleotide probe system was designed that allows detection of the complementary target DNA sequence. This exciplex-based fluorescence detector system operates by means of a contiguous hybridization of two oligonucleotide exciplex split-probes to a complementary target nucleic acid target. Each probe oligonucleotide is chemically modified at one of its termini by a potential exciplex-forming partner, each of which is fluorescently silent at the wavelength of detection. Under conditions that ensure correct three-dimensional assembly, the chemical moieties on suitable photoexcitation form an exciplex that fluoresces with a large Stokes shift (in this case 130 nm). Preliminary proof-of-concept studies used two 8-mer probe oligonucleotides, but in order to give better specificity for genomic applications, probe length was extended to give coverage of 24 bases. Eight pairs of tandem 12-mer oligonucleotide probes spanning the 2C9*3 region were designed and tested to find the best set of probes. Target sequences tested were in the form of (i) synthetic oligonucleotides, (ii) embedded in short PCR products (150 bp), or (iii) inserted into plasmid DNA (~ 3 Kbp). The exciplex system was able to differentiate wild type and human cytochrome P450 2C9 *3 SNP (1075 A→C) alleles, based on fluorescence emission spectra and DNA melting curves, indicating promise for future applications in genetic testing and molecular diagnostics.  相似文献   

11.
A number of novel gene detection techniques all revolve around the ligation of synthetic nucleic acid probes. In such ligase-assisted gene detection reactions, specific DNA or RNA sequences are investigated by using them as guides for the covalent joining of pairs of probe molecules. The probes are designed to hybridize immediately next to each other on the target nucleic acid strand. Demonstration of ligated probes results in highly specific detection of and efficient distinction between similar sequence variants under standard reaction conditions. Accordingly, the principle has been applied in automated genetic screening procedures. Ligation reactions are also integral to a number of amplification procedures and they will be of value in an expanding range of genetic analyses.  相似文献   

12.
In this paper, a simple and useful approach for DNA sensing based on surface plasmon resonance (SPR) transduction is reported. A new DNA sample pre-treatment has been optimised to allow fast and simple detection of hybridisation reaction between a target sequence in solution and a probe immobilised on the sensing surface. This pre-treatment consisted in a denaturation procedure of double stranded DNA containing the target sequence and was based on an high temperature treatment (95 degrees C, 5 min) followed by a 1 min incubation with small oligonucleotides. The oligonucleotides are designed to prevent the re-hybridising of the denatured strands, while enabling the target sequence to bind the immobilised probe. The important parameters of the procedure, i.e. incubation time, length and concentration of the oligonucleotides, have been studied in detail. The optimised DNA denaturation procedure has been successfully applied to the detection of amplified DNA with a commercially available SPR biosensor (Biacore X). DNA samples extracted from plant and human blood were tested after amplification by polymerase chain reaction (PCR).  相似文献   

13.
In this study, a novel single universal primer multiplex ligation-dependent probe amplification (SUP-MLPA) technique that uses only one universal primer to perform multiplex polymerase chain reaction (PCR) was developed. Two reversely complementary common sequences were designed on the 5′ or 3′ end of the ligation probes (LPs), which allowed the ligation products to be amplified through only a single universal primer (SUP). SUP-MLPA products were analyzed on sequencing gel electrophoresis with extraordinary resolution. This method avoided the high expenses associated with capillary electrophoresis, which was the commonly used detection instrument. In comparison with conventional multiplex PCR, which suffers from low sensitivity, nonspecificity, and amplification disparity, SUP-MLPA had higher specificity and sensitivity and a low detection limit of 0.1 ng for detecting single crop species when screening the presence of genetically modified crops. We also studied the effect of different lengths of stuffer sequences on the probes for the first time. Through comparing the results of quantitative PCR, the LPs with different stuffer sequences did not affect the ligation efficiency, which further increased the multiplicity of this assay. The improved SUP–MLPA and sequencing gel electrophoresis method will be useful for food and animal feed identification, bacterial detection, and verification of genetic modification status of crops.  相似文献   

14.
We describe a non-isotopic, semi-automated method for large-scale multiplex analysis of nucleic acid sequences, using the cystic fibrosis transmembrane regulator (CFTR) gene as an example. Products of a multiplex oligonucleotide ligation assay (OLA) are resolved electrophoretically from one another and from unligated probes under denaturing conditions with fluorescence detection. One ligation probe for each OLA target carries a fluorescent tag, while the other probe carries an oligomeric non-nucleotide mobility modifier. Each OLA product has a unique electrophoretic mobility determined by the ligated oligonucleotides and the mobility-modifier oligomer arbitrarily assigned (coded) to its target. The mobility range for practical mobility modifiers is much wider than the accessible range from unmodified ligated oligonucleotides of practical length. Each mobility modifier is built from phosphoramidite monomers in a stepwise manner on its associated oligonucleotide using an automated synthesizer. The resulting mobility modifiers lower the probe-target duplex Tm by less than 3 degrees C and retard probe-target annealing by less than 50%, with negligible effect on OLA yield and specificity. This method is especially useful for allelic discrimination in highly polymorphic genes such as CFTR.  相似文献   

15.
A novel leaky surface acoustic wave (LSAW) bis-peptide nucleic acid (bis-PNA) biosensor with double two-port resonators has been constructed successfully for the quantitative detection of human papilloma virus (HPV). The bis-PNA probe can directly detect HPV genomic DNA without polymerase chain reaction (PCR) amplification, and it can bind to the target DNA sequences more effectively and specifically than a DNA probe. When the concentrations varied from 1 pg/L to 1000 μg/L, with 100 μg/L being the optimal, a typical linearity was found between the quantity of target and the phase shifts. The detection limit was 1.21 pg/L and the clinical specificity was 97.22% of that of real-time PCR. The bis-PNA probe was able to distinguish sequences that differ only in one base. Both the intraassay and interassay coefficients of variance (CVs) were <10%, and the biosensor can be regenerated for ten times without appreciable loss of activity. Therefore, this technical platform of LSAW biosensor can be applied to clinical samples for direct HPV detection.  相似文献   

16.
Genotyping in closed tube is commonly performed using polymerase chain reaction (PCR) amplification and allele-specific oligonucleotide probes using fluorescence resonance energy transfer (FRET). Here we introduce a homogeneous human leukocyte antigen (HLA)–DQA1∗05 end-point PCR assay based on switchable lanthanide luminescence probe technology and a simple dried blood sample preparation. The switchable probe technology is based on two non-luminescent oligonucleotide probes: one carrying a non-luminescent lanthanide chelate and the other carrying a light-absorbing antenna ligand. Hybridization of the probes in adjacent positions to the target DNA leads to the formation of a highly luminescent lanthanide chelate complex by self-assembly of the reporter molecules. Performance of the HLA–DQA1∗05 assay was evaluated by testing blood samples collected on sample collection cards and was prepared by lysing the punched samples (3-mm discs) using alkaline reaction conditions and high temperature. Testing of 147 blood samples yielded 100% correlation to the heterogeneous DELFIA technology-based reference assay. Genotyping requires carefully designed probe sequences able to discriminate matched and mismatched target sequences by hybridization. Furthermore, definite genotype discrimination was achieved because inherently non-luminescent switchable probes together with time-resolved measurement mode led to very low background signal level and, therefore, very high signal differences averaging 54-fold between DQA1∗05 and other alleles.  相似文献   

17.
D Y Wu  R B Wallace 《Genomics》1989,4(4):560-569
A novel DNA sequence detection method that utilizes the ligation of oligonucleotide pairs that are complementary to adjacent sites on appropriate DNA templates is described. The product is increased by either linear or exponential amplification using sequential rounds of template-dependent ligation. In the case of linear amplification, a single pair of oligonucleotides is ligated, the reaction is heated to dissociate the ligation product, and an additional round of ligation is performed. After n rounds there is a (1 + x) X n-fold amplification of product, where x is the efficiency of the ligation reaction. Exponential amplification utilizes two pairs of oligonucleotides, one complementary to the upper strand and one to the lower strand of a target sequence. The products of the ligation reaction serve as templates for subsequent rounds of ligation. In this case there is (1 + x)(n-1)-fold amplification of product after n rounds. A single base-pair mismatch between the annealed oligonucleotides and the template prevents ligation, thus allowing the distinction of single base-pair differences between DNA templates. At high template concentrations, the ligation reaction has an efficiency approaching 100%. In this report, we demonstrate the use of the ligation amplification reaction (LAR) to distinguish the normal from the sickle cell allele of the human beta-globin gene. We also report the use of LAR as a detection system for polymerase chain reaction-enriched DNA sequences.  相似文献   

18.
Mutations in the methyl-CpG-binding protein-2 (MECP2) gene on Xq28 have been found to be a cause of Rett syndrome (RS). In a previous mutation screening, we found MECP2 mutations in 81% of Swedish classical Rett women. In this study, we have analyzed 22 patients for MECP2 deletions using multiplex-ligation-dependent probe amplification (MLPA). Clinically, 11 of the patients who were classical Rett women, 3 were forme fruste, 1 was congenital RS, and 7 were Rett variants. As inclusion criteria, we used DNA from patients in whom previous sequencing results showed no mutations in coding portions of the MECP2 gene. MLPA is a method based on multiplex PCR. In one PCR, as many as 40 probes are amplified with the same primers. The specificity of the amplification products is determined by the site-specific hybridization of each probe construct, prior to amplification. Each PCR product has a unique length, which makes it possible to identify it by size separation. In 3 of 11 (27%) classical Rett women, we detected large deletions in MECP2 using MLPA. All these patients had deletions covering two exons; in 2 cases the deletion involved exons 3 and 4 and, in one case, exons 1 and 2 were missing. In the forme fruste, congenital and Rett-variant patients, we found no large deletions. We have found that MLPA is useful when it comes to finding large deletions compromising whole exons in MECP2. Used as a complementary method to DNA sequencing, it revealed new MECP2 mutations in classical RS patients.  相似文献   

19.
We developed a software program for the rapid selection of detection probes to be used in nucleic acid-based assays. In comparison to commercially available software packages, our program allows the addition of oligotags as required by nucleic acid sequence-based amplification (NASBA) as well as automatic BLAST searches for all probe/primer pairs. We then demonstrated the usefulness of the program by designing a novel lateral flow biosensor for Streptococcus pyogenes that does not rely on amplification methods such as the polymerase chain reaction (PCR) or NASBA to obtain low limits of detection, but instead uses multiple reporter and capture probes per target sequence and an instantaneous amplification via dye-encapsulating liposomes. These assays will decrease the detection time to just a 20 min hybridization reaction and avoid costly enzymatic gene amplification reactions. The lateral flow assay was developed quantifying the 16S rRNA from S. pyogenes by designing reporter and capture probes that specifically hybridize with the RNA and form a sandwich. DNA reporter probes were tagged with dye-encapsulating liposomes, biotinylated DNA oligonucleotides were used as capture probes. From the initial number of capture and reporter probes chosen, a combination of two capture and three reporter probes were found to provide optimal signal generation and significant enhancement over single capture/reporter probe combinations. The selectivity of the biosensor was proven by analyzing organisms closely related to S. pyogenes, such as other Streptococcus and Enterococcus species. All probes had been selected by the software program within minutes and no iterative optimization and re-design of the oligonucleotides was required which enabled a very rapid biosensor prototyping. While the sensitivity obtained with the biosensor was only 135 ng, future experiments will decrease this significantly by the addition of more reporter and capture probes for either the same rRNA or a different nucleic acid target molecule. This will lead to the possibility of detecting S. pyogenes with a rugged assay that does not require a cell culturing or gene amplification step and will therefore enable rapid, specific and sensitive onsite testing.  相似文献   

20.
R A Heller  K Song  J Freire-Moar 《BioTechniques》1992,12(1):30, 32, 34-30, 32, 35
The PCR technique can use protein-derived oligonucleotide sequences as primers to develop probes for screening recombinant libraries. Here we report a method with highly degenerate mixtures of oligonucleotides as primers for the PCR that eliminates the need to identify or isolate the DNA sequences derived by PCR. The method uses the pool of PCR-generated DNA sequences radiolabeled during the extension reaction as a probe, combined with highly stringent hybridization and wash conditions that permit only homologous sequences to hybridize and therefore target desired clones. This technique was used successfully to clone the receptor for tumor necrosis factor.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号