首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Nanosecond, high‐voltage electric pulses (nsEP) induce permeabilization of the plasma membrane and the membranes of cell organelles, leading to various responses in cells including cytochrome c release from mitochondria and caspase activation associated with apoptosis. We report here evidence for nsEP‐induced permeabilization of mitochondrial membranes in living cells. Using three different methods with fluorescence indicators—rhodamine 123 (R123), tetramethyl rhodamine ethyl ester (TMRE), and cobalt‐quenched calcein—we have shown that multiple nsEP (five pulses or more, 4 ns duration, 10 MV/m, 1 kHz repetition rate) cause an increase of the inner mitochondrial membrane permeability and an associated loss of mitochondrial membrane potential. These effects could be a consequence of nsEP permeabilization of the inner mitochondrial membrane or the activation of mitochondrial membrane permeability transition pores. Plasma membrane permeabilization (YO‐PRO‐1 influx) was detected in addition to mitochondrial membrane permeabilization. Bioelectromagnetics 33:257–264, 2012. © 2011 Wiley Periodicals, Inc.  相似文献   

2.
The charging of the plasmalemma is a necessary condition for permeabilization of the plasma membrane (electroporation) in response to external electric field exposure. Common theories explain this permeabilization by formation of pores in the lipid bilayer. Using pulsed laser fluorescence microscopy, we measured the charging process of the membrane during the application of an external electric field with a temporal resolution of 5 ns. Visualization of the charging process of protoplasts plasma membrane (Nicotiana tabacum Bright Yellow 2) was achieved by staining of the plasma membrane with the voltage-sensitive fluorescent dye ANNINE-6. Measurements on membranes exhibiting negligible membrane permeabilization confirm the sine-shaped azimuthal distribution of the membrane voltage predicted by the relation of Cole. At higher membrane voltages, enhanced pore formation allows for the exchange of charge carriers, leading to deviations from the sine-shaped curve progression, i.e., a saturation of the membrane voltage at membrane segments facing the electrodes. Additionally, measurements on protoplasts exposed to multiple successive pulses indicate that the recovery of the membrane seems to be a fast process, occurring within seconds after termination of the external electric field pulse.  相似文献   

3.
Reversible electropermeabilization (electroporation) is widely used to facilitate the introduction of genetic material and pharmaceutical agents into living cells. Although considerable knowledge has been gained from the study of real and simulated model membranes in electric fields, efforts to optimize electroporation protocols are limited by a lack of detailed understanding of the molecular basis for the electropermeabilization of the complex biomolecular assembly that forms the plasma membrane. We show here, with results from both molecular dynamics simulations and experiments with living cells, that the oxidation of membrane components enhances the susceptibility of the membrane to electropermeabilization. Manipulation of the level of oxidative stress in cell suspensions and in tissues may lead to more efficient permeabilization procedures in the laboratory and in clinical applications such as electrochemotherapy and electrotransfection-mediated gene therapy.  相似文献   

4.
The permeabilization of tumor cells in vitro under the action of pulsed electric fields with a duration of 6 mks in the range of amplitudes 1-7 kV/cm was studied. In the mode of excitation in the ambience of localized plasma discharge in a chamber of special design, an enhanced damage to cells in suspension was observed. It is assumed that the enhancement is due to the synchronous action of the electric field and acoustic shock wave pulses. In the mode without the plasma breakdown of ambience, when the pulse duration of electric field of intensity of 1-2 kV/cm was increased to 60 mks, the efficiency of permeabilization increases nearly by one order. The experimental results are compared with the known theoretical models of cell membrane electroporation.  相似文献   

5.
Application of ultrasound transiently permeabilizes cell membranes and offers a nonchemical, nonviral, and noninvasive method for cellular drug delivery. Although the ability of ultrasound to increase transmembrane transport has been well demonstrated, a systematic dependence of transport on ultrasound parameters is not known. This study examined cell viability and cellular uptake of calcein using 3T3 mouse cell suspension as a model system. Cells were exposed to varying acoustic energy doses at four different frequencies in the low frequency regime (20-100 kHz). At all frequencies, cell viability decreased with increasing acoustic energy dose, while the fraction of cells exhibiting uptake of calcein showed a maximum at an intermediate energy dose. Acoustic spectra under various ultrasound conditions were also collected and assessed for the magnitude of broadband noise and subharmonic peaks. While the cell viability and transport data did not show any correlation with subharmonic (f/2) emission, they correlated with the broadband noise, suggesting a dominant contribution of transient cavitation. A theoretical model was developed to relate reversible and irreversible membrane permeabilization to the number of transient cavitation events. The model showed that nearly every stage of transient cavitation, including bubble expansion, collapse, and subsequent shock waves may contribute to membrane permeabilization. For each mechanism, the volume around the bubble within which bubbles induce reversible and irreversible membrane permeabilization was determined. Predictions of the model are consistent with experimental data.  相似文献   

6.
Treatment of biological material by pulsed electric fields is a versatile technique in biotechnology and biomedicine used, for example, in delivering DNA into cells (transfection), ablation of tumors, and food processing. Field exposure is associated with a membrane permeability increase usually ascribed to electroporation, i.e., formation of aqueous membrane pores. Knowledge of the underlying processes at the membrane level is predominantly built on theoretical considerations and molecular dynamics (MD) simulations. However, experimental data needed to monitor these processes with sufficient temporal resolution are scarce. The whole-cell patch-clamp technique was employed to investigate the effect of millisecond pulsed electric fields on DC-3F cells. Cellular membrane permeabilization was monitored by a conductance increase. For the first time, to our knowledge, it could be established experimentally that electroporation consists of two clearly separate processes: a rapid membrane poration (transient electroporation) that occurs while the membrane is depolarized or hyperpolarized to voltages beyond so-called threshold potentials (here, +201 mV and −231 mV, respectively) and is reversible within ∼100 ms after the pulse, and a long-term, or persistent, permeabilization covering the whole voltage range. The latter prevailed after the pulse for at least 40 min, the postpulse time span tested experimentally. With mildly depolarizing or hyperpolarizing pulses just above threshold potentials, the two processes could be separated, since persistent (but not transient) permeabilization required repetitive pulse exposure. Conductance increased stepwise and gradually with depolarizing and hyperpolarizing pulses, respectively. Persistent permeabilization could also be elicited by single depolarizing/hyperpolarizing pulses of very high field strength. Experimental measurements of propidium iodide uptake provided evidence of a real membrane phenomenon, rather than a mere patch-clamp artifact. In short, the response of DC-3F cells to strong pulsed electric fields was separated into a transient electroporation and a persistent permeabilization. The latter dominates postpulse membrane properties but to date has not been addressed by electroporation theory or MD simulations.  相似文献   

7.
Electric field induced permeabilization of cell membranes is an important technique for gene transfection and cell hybridization. Mechanistic studies of this process revealed that the uptake of fluorescent indicator by plant protoplasts occurs predominantly on the hemisphere facing the positive electrode, while in erythrocyte ghosts the probes exit through the hemisphere facing the negative electrode. To reconcile these observations symmetrical pore formation and a mechanism of molecular exchange by electroosmosis has been proposed. In light of these controversial observations, we conducted a systematic study of electroporation of NIH3T3 cells with varying electric field strength, waveform and frequency. Our data revealed that (i) symmetrical permeabilization of the cell membrane occurs only with bipolar a.c. fields. (ii) When a critical membrane breakdown potential, Vc, is applied using either an unipolar a.c. fields or a single d.c. square pulse, the cell membrane becomes permeabilized only at the hemisphere facing the positive electrode. (iii) When the pulse-induced membrane potential, Vm, is approximately equal to or larger than the intrinsic membrane potential (i.e. using d.c. or unipolar a.c. field), asymmetric permeabilization was observed with the hemisphere facing the positive electrode being most permeable. (iv) The rate of fluorescent indicator uptake is dependent on the concentration of the indicator. These results indicate that electro-permeabilization of cell membranes is affected by its resting potential and that electroosmosis is not the dominant mechanism for the cellular uptake of foreign molecules in electroporation.  相似文献   

8.
The role of the shape of electric pulses of cell permeabilization and lysis was studied using the newly developed DPS electroporator. The effects of bipolar pulses, steep rising and falling edges in the pulses, delays between pulses, and shapes of DC signals between the edges on the lysis of bovine oocytes and the permeabilization of their cell membranes were investigated. Comparing the permeabilization rates with the lysis rates revealed a number of correlations, which make it possible to optimize the pulse shapes for achieving maximum permeabilization rates while keeping the lysis rates low. The optimization of pulse shape is essential for improving the procedure of electroporation in mammalian cloning technology.  相似文献   

9.
The biological effects of electric pulses with low rise time, high field strength, and durations in the nanosecond range (nsPEFs) have attracted considerable biotechnological and medical interest. However, the cellular mechanisms causing membrane permeabilization by nanosecond pulsed electric fields are still far from being understood. We investigated the role of actin filaments for membrane permeability in plant cells using cell lines where different degrees of actin bundling had been introduced by genetic engineering. We demonstrate that stabilization of actin increases the stability of the plasma membrane against electric permeabilization recorded by penetration of Trypan Blue into the cytoplasm. By use of a cell line expressing the actin bundling WLIM domain under control of an inducible promotor we can activate membrane stabilization by the glucocorticoid analog dexamethasone. By total internal reflection fluorescence microscopy we can visualize a subset of the cytoskeleton that is directly adjacent to the plasma membrane. We conclude that this submembrane cytoskeleton stabilizes the plasma membrane against permeabilization through electric pulses.  相似文献   

10.
Changes in growth kinetics and metabolic activity of microorganisms under the presence of a moderate electric field (MEF) have been hypothesized as being due to temporary permeabilization of cell membranes. We investigated herein the effects of frequency and growth stage on cell membrane permeabilization of Lactobacillus acidophilus OSU 133 during MEF fermentation. Cells were stained with two fluorescent nucleic acid stains: the green, nonselective, cell membrane permeable SYTO 9, and the red, cell membrane impermeable propidium iodide (PI). Fluorescence exhibition post‐treatment was assessed using fluorescence microscopy. Total plate counting was done to determine whether or not the permeabilized population represented live cells. Fermentation treatments investigated were conventional (control) and MEF (2 V/cm, 45, 60, 1,000, 10,000 Hz) at 30°C. Studies were conducted at 45 Hz for lag, exponential, and stationary phases of growth. Low frequency MEF treated cells exhibited significantly greater numbers of red cell counts than conventional treatments; further, no significant differences existed in viable counts between MEF and conventional treatments, suggesting that the red counts represent permeabilized live cells. MEF treatments at the early stage of bacterial growth at 45 Hz exhibited the maximum permeabilization followed by treatments at 60 Hz. MEF treated samples at frequencies higher than 60 Hz did not exhibit red fluorescence. Cells at lag phase showed the greatest susceptibility to permeabilization followed by those at exponential phase. No evidence of electroporation was observed during the stationary phase. To our knowledge, these observations provide the first evidence that cell membrane permeabilization occurs under the presence of electric fields as low as those under MEF. © 2009 American Institute of Chemical Engineers Biotechnol. Prog., 2009  相似文献   

11.
It is widely accepted that electroporation occurs when the cell transmembrane voltage induced by an external applied electric field reaches a threshold. Under this assumption, in order to trigger electroporation in a spherical cell, Schwan’s equation leads to an inversely proportional relationship between the cell radius and the minimum magnitude of the applied electric field. And, indeed, several publications report experimental evidences of an inverse relationship between the cell size and the field required to achieve electroporation. However, this dependence is not always observed or is not as steep as predicted by Schwan’s equation. The present numerical study attempts to explain these observations that do not fit Schwan’s equation on the basis of the interplay between cell membrane conductivity, permeability, and transmembrane voltage. For that, a single cell in suspension was modeled and the electric field necessary to achieve electroporation with a single pulse was determined according to two effectiveness criteria: a specific permeabilization level, understood as the relative area occupied by the pores during the pulse, and a final intracellular concentration of a molecule due to uptake by diffusion after the pulse, during membrane resealing. The results indicate that plausible model parameters can lead to divergent dependencies of the electric field threshold on the cell radius. These divergent dependencies were obtained through both criteria and using two different permeabilization models. This suggests that the interplay between cell membrane conductivity, permeability, and transmembrane voltage might be the cause of results which are noncompatible with the Schwan’s equation model.  相似文献   

12.
In vivo electroporation is increasingly being used to deliver small molecules as well as DNA to tissues. The aim of this study was to quantitatively investigate in vivo electroporation of skeletal muscle, and to determine the threshold for permeabilization. We designed a quantitative method to study in vivo electroporation, by measuring uptake of (51)Cr-EDTA. As electrode configuration influences electric field (E-field) distribution, we developed a method to calculate this. Electroporation of mouse muscle tissue was investigated using either external plate electrodes or internal needle electrodes placed 4 mm apart, and eight pulses of 99 micros duration at a frequency of 1 Hz. The applied voltage to electrode distance ratio was varied from 0 to 2.0 kV/cm. We found that: (1) the threshold for permeabilization of skeletal muscle tissue using short duration pulses was at an applied voltage to electrode distance ratio of 0.53 kV/cm (+/-0.03 kV/cm), corresponding to an E-field of 0.45 kV/cm; (2) there were two phases in the uptake of (51)Cr-EDTA, the first indicating increasing permeabilization and the second indicating beginning irreversible membrane damage; and (3) the calculated E-field distribution was more homogeneous for plate than for needle electrodes, which was reflected in the experimental results.  相似文献   

13.
Conventional electroporation (EP) changes both the conductance and molecular permeability of the plasma membrane (PM) of cells and is a standard method for delivering both biologically active and probe molecules of a wide range of sizes into cells. However, the underlying mechanisms at the molecular and cellular levels remain controversial. Here we introduce a mathematical cell model that contains representative organelles (nucleus, endoplasmic reticulum, mitochondria) and includes a dynamic EP model, which describes formation, expansion, contraction, and destruction for the plasma and all organelle membranes. We show that conventional EP provides transient electrical pathways into the cell, sufficient to create significant intracellular fields. This emerging intracellular electrical field is a secondary effect due to EP and can cause transmembrane voltages at the organelles, which are large enough and long enough to gate organelle channels, and even sufficient, at some field strengths, for the poration of organelle membranes. This suggests an alternative to nanosecond pulsed electric fields for intracellular manipulations.  相似文献   

14.
Experimentally observed changes in the conductivity of skin under the influence of a pulsing electric field were theoretically analyzed on the basis of a proposed electrorheological model of the stratum corneum (SC). The dependence of relative changes in conductivity on the amplitude of electric field and timelike parameters of applied pulses or pulse trains have been mathematically described. Statistical characteristics of phenomena of transient and long-term electroporation of SC were taken into consideration. The time-dependent decreases of skin resistance depicted by the models were fitted to experimental data for transient and long-term skin permeabilization by electric pulses. The results show two characteristic times and two spectra of characteristic energies for transient and long-term permeabilizations. The rheological parameters derived from the fittings agreed with those reported elsewhere for biological membranes.  相似文献   

15.
Electric pulses across intact vesicles and cells can lead to transient increase in permeability of their membranes. We studied the integrity of these membranes in response to external electric pulses of high amplitude and submicrosecond duration with a primary aim of achieving selective permeabilization. These effects were examined in two separate model systems comprising of 1), a mixed population of 1,2-di-oleoyl-sn-glycero-3-phosphocholine phospholipid vesicles and in 2), single COS-7 cells, in which large endosomal membrane vacuoles were induced by stimulated endocytosis. It has been shown that large and rapidly varying external electric fields, with pulses shorter than the charging time of the outer-cell membrane, could substantially increase intracellular fields to achieve selective manipulations of intracellular organelles. The underlying principle of this earlier work is further developed and applied to the systems studied here. Under appropriate conditions, we show preferential permeabilization of one vesicle population in a mixed preparation of vesicles of similar size distribution. It is further shown that large endocytosed vacuoles in COS-7 cells can be selectively permeabilized with little effect on the integrity of outer cell membrane.  相似文献   

16.
《Biophysical journal》2022,121(6):869-885
Electric phenomena in brain tissue can be measured using extracellular potentials, such as the local field potential, or the electro-encephalogram. The interpretation of these signals depends on the electric structure and properties of extracellular media, but the measurements of these electric properties are still debated. Some measurements point to a model in which the extracellular medium is purely resistive, and thus parameters such as electric conductivity and permittivity should be independent of frequency. Other measurements point to a pronounced frequency dependence of these parameters, with scaling laws that are consistent with capacitive or diffusive effects. However, these experiments correspond to different preparations, and it is unclear how to correctly compare them. Here, we provide for the first time, impedance measurements (in the 1–10 kHz frequency range) using the same setup in various preparations, from primary cell cultures to acute brain slices, and a comparison with similar measurements performed in artificial cerebrospinal fluid with no biological material. The measurements show that when the current flows across a cell membrane, the frequency dependence of the macroscopic impedance between intracellular and extracellular electrodes is significant, and cannot be captured by a model with resistive media. Fitting a mean-field model to the data shows that this frequency dependence could be explained by the ionic diffusion mainly associated with Debye layers surrounding the membranes. We conclude that neuronal membranes and their ionic environment induce strong deviations to resistivity that should be taken into account to correctly interpret extracellular potentials generated by neurons.  相似文献   

17.
Transient membrane permeabilization by application of high electric field intensity pulses on cells (electropermeabilization) depends on several physical parameters associated with the technique (pulse intensity, number, and duration). In the present study, electropermeabilization is studied in terms of flow of diffusing molecules between cells and external medium. Direct quantification of the phenomenon shows that electric field intensity is a critical parameter in the induction of permeabilization. Electric field intensity must be higher than a critical threshold to make the membrane permeable. This critical threshold depends on the cell size. Extent of permeabilization (i.e., the flow rate across the membrane) is then controlled by both pulse number and duration. Increasing electric field intensity above the critical threshold needed for permeabilization results in an increase membrane area able to be permeabilized but not due to an increase in the specific permeability of the field alterated area. The electroinduced permeabilization is transient and disappears progressively after the application of the electric field pulses. Its life time is under the control of the electric field parameters. The rate constant of the annealing phase is shown to be dependent on both pulse duration and number, but is independent of electric field intensity which creates the permeabilization. The phenomenon is described in terms of membrane organization transition between the natural impermeable state and the electro-induced permeable state, phenomenon only locally induced for electric field intensities above a critical threshold and expanding in relation to both pulse number and duration.  相似文献   

18.
Troszak GD  Rubinsky B 《PloS one》2011,6(4):e18523
Electroporation, the permeabilization of the cell membrane lipid bilayer due to a pulsed electric field, has important implications in the biotechnology, medicine, and food industries. Traditional macro and micro-electroporation devices have facing electrodes, and require significant potential differences to induce electroporation. The goal of this theoretical study is to investigate the feasibility of singularity-induced micro-electroporation; an electroporation configuration aimed at minimizing the potential differences required to induce electroporation by separating adjacent electrodes with a nanometer-scale insulator. In particular, this study aims to understand the effect of (1) insulator thickness and (2) electrode kinetics on electric field distributions in the singularity-induced micro-electroporation configuration. A non-dimensional primary current distribution model of the micro-electroporation channel shows that while increasing insulator thickness results in smaller electric field magnitudes, electroporation can still be performed with insulators thick enough to be made with microfabrication techniques. Furthermore, a secondary current distribution model of the singularity-induced micro-electroporation configuration with inert platinum electrodes and water electrolyte indicates that electrode kinetics do not inhibit charge transfer to the extent that prohibitively large potential differences are required to perform electroporation. These results indicate that singularity-induced micro-electroporation could be used to develop an electroporation system that consumes minimal power, making it suitable for remote applications such as the sterilization of water and other liquids.  相似文献   

19.
Clinical electroporation (EP) is a rapidly advancing treatment modality that uses electric pulses to introduce drugs or genes into, e.g., cancer cells. The indication of successful EP is an instant plasma membrane permeabilization in the treated tissue. A noninvasive means of monitoring such a tissue reaction represents a great clinical benefit since, in case of target miss, retreatment can be performed immediately. We propose diffusion-weighted magnetic resonance imaging (DW-MRI) as a method to monitor EP tissue, using the concept of the apparent diffusion coefficient (ADC). We hypothesize that the plasma membrane permeabilization induced by EP changes the ADC, suggesting that DW-MRI constitutes a noninvasive and quick means of EP verification. In this study we performed in vivo EP in rat brains, followed by DW-MRI using a clinical MRI scanner. We found a pulse amplitude–dependent increase in the ADC following EP, indicating that (1) DW-MRI is sensitive to the EP-induced changes and (2) the observed changes in ADC are indeed due to the applied electric field.  相似文献   

20.
Electroporation relates to the cascade of events that follows the application of high electric fields and that leads to cell membrane permeabilization. Despite a wide range of applications, little is known about the electroporation threshold, which varies with membrane lipid composition. Here, using molecular dynamics simulations, we studied the response of dipalmitoyl-phosphatidylcholine, diphytanoyl-phosphocholine-ester and diphytanoyl-phosphocholine-ether lipid bilayers to an applied electric field. Comparing between lipids with acyl chains and methyl branched chains and between lipids with ether and ester linkages, which change drastically the membrane dipole potential, we found that in both cases the electroporation threshold differed substantially. We show, for the first time, that the electroporation threshold of a lipid bilayer depends not only on the “electrical” properties of the membrane, i.e., its dipole potential, but also on the properties of its component hydrophobic tails.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号