首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 30 毫秒
1.
An automated method for the determination of pholcodine in plasma and whole blood is described. The technique combines dialysis and trace enrichment prior to high-performance liquid chromatography. Dialysis, trace enrichment on a weak cation-exchange column, separation on a cyano column and fluorescence detection was shown to be an extremely selective and sensitive method. The method has been used successfully in the analysis of real samples after administration of pholcodine. The automated method can be used, after minor modification, to determine other basic drugs in whole blood and plasma.  相似文献   

2.
A colorimetric method for the determination of total sulfhydryl content whole blood or plasma is presented. For whole blood, a mixture of fresh blood and 5,5′-dithiobis(2-nitrobenzoic acid) in diluted buffer is separated on a gel column into the yellow anion and the hemoglobin fraction. The plasma-DTNB mixture was read directly, and a correction for turbidity and/or color made after addition of N-ethylmaleimide. Results of a sample of human bloods are presented. The effects of several detergents yield high values of sulfhydryl in whole blood, which we believe to be artifactual. Studies of the stability of stored blood samples indicate that whole blood, but not plasma, can be kept refrigerated for several days without significant loss of sulfhydryl reaction.  相似文献   

3.
A sensitive method for the specific determination of creatinine in whole blood, plasma, and urine with high precision and accuracy is described. Samples were deproteinized by addition of acetonitrile and analyzed by high-performance liquid chromatography using a cation-exchange column with a mobile phase of 9% acetonitrile in 40 mM ammonium phosphate (pH 4.0). The recoveries of creatinine added to blood and plasma were almost complete, ranging from 99 to 101%. The coefficients of variation were very small, 1.6% for blood and plasma and 1.5% for urine. Samples can be assayed in 11-min intervals subsequent to the initial injection. As little as 2 microliter of blood or plasma or 0.02 microliter of urine is sufficient for chromatographic analysis. The present method was successfully used for the accurate measurement of small arterial-venous differences of creatinine concentrations in blood across body organs and showed that in the sheep creatinine is produced in the muscles and is excreted by the kidneys. The method is also suitable for routine analysis of creatinine in clinical laboratories.  相似文献   

4.
An improved high-performance liquid chromatography method using a diisopropyl-C14 reversed-phase column (Zorbax Bonus-RP column) and a liquid–liquid extraction technique with UV detection is presented for the analysis of pyronaridine in human whole blood and plasma. Tribasic phosphate buffer (50 mM, pH 10.3) and diethyl ether were used for liquid–liquid extraction. The mobile phase consists of acetonitrile–0.08 M potassium dihydrogen phosphate buffer (13:87, v/v) with the pH 2.8 adjusted by orthophosphoric acid. Amodiaquine was found to be a suitable internal standard for the method. The quantification limit with UV detection at 275 nm was 3 ng on-column for both plasma and blood samples. The method was applied to plasma and blood specimens from a rabbit after a single intramuscular dose of pyronaridine tetraphosphate (20 mg/kg as base). From this in vivo study, evidence was found that pyronaridine is concentrated in blood cells, with a blood:plasma ratio ranging from 4.9 to 17.8. We conclude that blood is the preferred matrix for clinical pharmacokinetic studies.  相似文献   

5.
A rapid, sensitive, and specific high-performance liquid chromatographic method is described for the quantitative analysis of dipyridamole in plasma and whole blood. The method involves a single extraction of an alkalinized sample with diethyl ether followed by evaporation of the organic solvent and ion-pair chromatography using fluorescence detection. The lower limit of sensitivity for dipyridamole is 1 ng/ml. Concentrations of dipyridamole between 1 and 500 ng per sample are measured with an average coefficient of variation of 4.5% in plasma and 7.4% in whole blood.  相似文献   

6.
A simple, accurate and sensitive high-performance liquid chromatographic method was developed for the determination of propofol, an intravenous anaesthetic agent, in rat whole blood or plasma samples. The method is based on precipitation of the protein in the biological fluid sample and direct injection of the supernatant into an HPLC system involving a C18 reversed-phase column using a methanol-water (70:30) mobile phase delivered at 1 ml/min. Propofol and the internal standard (4-tert.-octylphenol) were quantified using a fluorescence detector set at 276 nm (excitation) and 310 nm (emission). The analyte and internal standard had retention times of 6.3 and 10.5 min, respectively. The limit of quantification for propofol was 50 ng/ml using 100 μl of whole blood or plasma sample. Calibration curves were linear (r2=0.99) over a 1–10 μg/ml concentration range and intra- and inter-day precision were between 4–11%. The assay was applied to the determination of propofol whole blood pharmacokinetics and propofol whole blood to plasma distribution ratios in rats.  相似文献   

7.
It is previously shown that surface plasmon resonance (SPR) can be used to study blood plasma coagulation. This work explores the use of this technique for the analysis of tissue factor induced coagulation, i.e. prothrombin time (PT) analysis, of whole blood and plasma. The reference method was nephelometry. The prothrombin time analysis by SPR was performed by mixing two volumes of blood/plasma, one volume of thromboplastin, and one volume of CaCl2 solution directly on a sensor surface. The measurements show good agreement between nephelometry and SPR plasma analysis and also between SPR plasma and whole blood analysis. The effect of anticoagulant treatment on the clotting times was significant both quantitatively and qualitatively. The impact on the SPR signal of different physiological events in the coagulation process is discussed, and tentative interpretations of the sensorgram features are given. The major advantage of the SPR method compared to nephelometry is the possibility to perform analysis on whole blood instead of plasma. In conclusion, SPR is a promising method for whole blood coagulation analysis.  相似文献   

8.
A highly sensitive HPLC method for enantioselective determination of carvedilol in human whole blood and plasma was developed. Carvedilol and S-carazolol as an internal standard extracted from whole blood or plasma were separated using an enantioselective separation column (Chiralpak AD column; 2.0 diameter x 250 mm) without any chiral derivatizations. The mobile phase was hexane:isopropanol:diethylamine (78:22:1, v/v). The excitation and emission wavelengths were set at 284 and 343 nm, respectively. The limits of quantification for the S(-)- and R(+)-carvedilol enantiomers in plasma and blood were both 0.5 ng/ml. Intra- and inter-day variations were less than 5.9%. As an application of the assay, concentrations of carvedilol enantiomer in plasma and blood samples from 15 patients treated with carvedilol for congestive heart failure were determined.  相似文献   

9.
The important biogenic amine, serotonin (5HT), was determined in whole blood, platelet-rich plasma (PRP), platelet-poor plasma (PPP), and plasma ultrafiltrate after simple deproteinization. Following ion-pair chromatography on standard or narrow-bore reverse-phase columns, 5HT and the internal standard (N-methylserotonin-NMS) were detected by fluorometry with absolute detection limits of 2-4 pg. Levels obtained for whole blood and PRP were in agreement with previous methods. However, mean (+/- SD) values obtained for platelet-poor plasma (PPP) of 578 +/- 277 pg/ml (N = 7) were approximately 3-fold lower than the lowest previous reports. We also report the first determination of 5HT in plasma ultrafiltrate, having observed mean levels of 387 +/- 222 pg/ml (N = 7).  相似文献   

10.
A liquid chromatography/electrospray ionization mass spectrometry (LC-ESI-MS) method was developed for the first time for the determination of ibogaine and noribogaine in human plasma and whole blood. The method involved solid phase extraction of the compounds and the internal standard (fluorescein) from the two matrices using OasisHLB columns. LC separation was performed on a Zorbax eclipse XD8 C8 column (5 microm) with a mobile phase of acetonitrile containing 0.02% (v/v) trimethylamine and 2mM ammonium formate buffer. MS data were acquired in single ion monitoring mode at m/z 311.2, 297.2 and 332.5 for ibogaine, noribogaine and fluorescein, respectively. The drug/internal standard peak area ratios were linked via a quadratic relationship to plasma (0.89-179 microg/l for ibogaine; 1-200 microg/l for noribogaine) and to whole blood concentrations (1.78-358 microg/kg for ibogaine; 2-400 microg/kg for noribogaine). Precision ranged from 4.5 to 13% and accuracy was 89-102%. Dilution of the samples had no influence on the performance of the method. Extraction recoveries were > or =94% in plasma and > or =57% in whole blood. The lower limits of quantitation were 0.89 microg/l for ibogaine and 1 microg/l for noribogaine in plasma, and 1.78 microg/kg for ibogaine and 2 microg/kg for noribogaine in whole blood. In frozen plasma samples, the two drugs were stable for at least 1 year. In blood, ibogaine and noribogaine were stable for 4h at 4 degrees C and 20 degrees C and 2 months at -20 degrees C. The method was successfully used for the analysis of a poisoning involving Tabernanthe iboga root.  相似文献   

11.
We have characterized the fluorescence spectral properties of rhodamine 800 (Rh800) in plasma and blood in order to test the possibility of making clinical fluorescence measurements in whole blood without separation steps. Rh800 was used because of its absorption at red/near-infrared wavelengths away from the absorption bands of hemoglobin. We utilized the front-face illumination and detection to minimize the effects of absorption and/or scatter during measurements. The presence of Rh800 was detected in plasma and blood using steady-state fluorescence measurements. Absorption due to hemoglobin reduced the Rh800 intensity from the blood. Fluorescence lifetime measurements in plasma and blood showed that it is possible to recover lifetime parameters of Rh800 in these media. We obtained mean lifetimes of 1.90 and 1.86 ns for Rh800 in plasma and blood, respectively. Using the recently described modulation sensing method, we quantified the concentrations of Rh800 in plasma and blood. Rh800 was detected at a concentration of as low as 2 microM in both media. High anisotropy values were obtained for Rh800 in plasma and blood using steady-state and anisotropy decay measurements, implying the tight binding of this probe to the contents of these media. This binding can be exploited to monitor the concentrations of different blood components using already existing or new red-emitting probes that will be specially designed to bind to these components with high specificity. To test this possibility of direct measurements in blood, we used Rh800 to monitor albumin in the presence of red blood cells. Increase in the polarization of Rh800 as the concentration of albumin was increased in the presence of the red cells showed the feasibility of such measurements.  相似文献   

12.
Thrombin is central to the process of coagulation and monitoring its activity is a reliable indicator of the rate and extent of coagulation. I have employed a range of fluorogenic peptide substrates as indicators of coagulation via the formation of active thrombin. This system enabled coagulation to be monitored in a kinetic fashion, and the use of fluorescence enabled a wide range of samples to be analyzed including lyophilized plasma containing fibrin, fresh platelet-poor plasma, platelet-rich plasma, and even whole blood. Coagulation could be monitored following triggering by tissue factor, ellagic acid, or each of the proteases preceding thrombin in the coagulation network. Using this assay procedure I have investigated the anticoagulant activities of a number of compounds and the results indicate that this assay would be useful for the kinetic analysis of coagulation in various plasma preparations, or even whole blood.  相似文献   

13.
We extended the application of a sensitive high-performance liquid chromatography assay of amoxicillin developed in this laboratory for human plasma and middle ear fluid (MEF) to other sample matrices including chinchilla plasma or MEF and human and chinchilla whole blood with minor modification and validated the limit of quantitation at 0.25 μg/ml with a 50-μl sample size for human and chinchilla plasmas or MEFs. Amoxicillin and cefadroxil, the internal standard, were extracted from 50 μl of the samples with Bond Elut C18 cartridges. The extract was analyzed on a Keystone MOS Hypersil-1 (C8) column with UV detection at 210 nm. The mobile phase was 6% acetonitrile in 5 mM phosphate buffer, pH 6.5 and 5 mM tetrabutylammonium. The within-day coefficients of variation were 2.7–9.9 (n=4) and 1.7–7.2% (n=3) for chinchilla plasma and MEF samples, respectively; 2.8–8.1% (n=3) and 2.9–4.7% (n=3) for human and chinchilla whole blood, respectively. An alternative mobile phase composition for chinchilla plasma and MEF samples reduced the analysis time significantly.  相似文献   

14.
The brain and other organs locally synthesize steroids. Local synthesis is suggested when steroid levels are higher in tissue than in the circulation. However, measurement of both circulating and tissue steroid levels are subject to methodological considerations. For example, plasma samples are commonly used to estimate circulating steroid levels in whole blood, but steroid levels in plasma and whole blood could differ. In addition, tissue steroid measurements might be affected by blood contamination, which can be addressed experimentally by using saline perfusion to remove blood. In Study 1, we measured corticosterone and testosterone (T) levels in zebra finch (Taeniopygia guttata) plasma, whole blood, and red blood cells (RBC). We also compared corticosterone in plasma, whole blood, and RBC at baseline and after 60 min restraint stress. In Study 2, we quantified corticosterone, dehydroepiandrosterone (DHEA), T, and 17β-estradiol (E2) levels in the brains of sham-perfused or saline-perfused subjects. In Study 1, corticosterone and T concentrations were highest in plasma, significantly lower in whole blood, and lowest in RBC. In Study 2, saline perfusion unexpectedly increased corticosterone levels in the rostral telencephalon but not other regions. In contrast, saline perfusion decreased DHEA levels in caudal telencephalon and diencephalon. Saline perfusion also increased E2 levels in caudal telencephalon. In summary, when comparing local and systemic steroid levels, the inclusion of whole blood samples should prove useful. Moreover, blood contamination has little or no effect on measurement of brain steroid levels, suggesting that saline perfusion is not necessary prior to brain collection. Indeed, saline perfusion itself may elevate and lower steroid concentrations in a rapid, region-specific manner.  相似文献   

15.
The aim of the study was to investigate the distribution of lactate in plasma, whole blood, erythrocytes, and capillary finger blood, before and during submaximal exercise. Ten healthy male subjects performed submaximal graded cycle ergometer exercise for 20-25 min. Venous blood samples and capillary finger blood samples were taken before exercise and every 5th min during exercise for lactate determination. The plasma lactate concentration was significantly higher (P less than 0.001, approximately 50%) than in the erythrocytes. This difference was not altered by the venous blood lactate concentration or exercise intensity. A significant difference (P less than 0.01) in lactate concentration was also found between capillary whole blood and venous whole blood. It was concluded that direct comparisons between lactate in capillary finger blood, venous whole blood and plasma could not be made.  相似文献   

16.
Platelet aggregation in platelet rich plasma (PRP) and whole blood was simultaneously studied in acute experiments on cats in hypocapnic conditions. ADP-induced aggregation increase was determined in PRP and whole blood. Contradictory results were obtained during platelet aggregation induced by collagen and arachidonic acid: increased aggregation in PRP and decreased aggregation in whole blood. The data obtained suggest that ADP is a risk factor for the onset of intravascular thrombosis.  相似文献   

17.
The measurement of amyloid beta peptides (Abeta) in blood and plasma is expected to be a useful biomarker as potential therapeutics designed to lower Abeta peptide enter clinical trials. Many reports have suggested that Abeta could bind to substances in blood that may influence the recovery of Abeta peptide in plasma, its detection by conventional ELISAs or the actual turnover and half-life of the peptide in blood. In this study we describe a process for analyzing total Abeta in whole blood and plasma using denaturing solid-phase extraction followed by reverse-phase HPLC linked to ELISA. Comparison of total Abeta peptide levels in whole blood and plasma from the same bleed showed that most of the Abeta peptide is captured in the plasma if the samples are first denatured. In contrast, plasma that was assayed without denaturation could show greater than 70% reduction in apparent total Abeta peptide. This suggested that there was a pool of Abeta peptide in non-denatured plasma that is occluded from detection by ELISA, perhaps by binding to plasma proteins.  相似文献   

18.
Because of its bactericidal and fungicidal properties, thimerosal is used as a preservative in drugs and vaccines and is thus deliberately injected into the human body. In aqueous environment, it decomposes into thiosalicylic acid and the ethylmercury cation. This organomercury fragment is a potent neurotoxin and is suspected to have similar toxicity and bioavailability like the methylmercury cation. In this work, human whole blood and physiological simulation solutions were incubated with thimerosal to investigate its behaviour and binding partners in the blood stream. Inductively coupled plasma with optical emission spectrometry (ICP-OES) was used for total mercury determination in different blood fractions, while liquid chromatography (LC) coupled to electrospray ionisation time-of-flight (ESI-TOF) and inductively coupled plasma-mass spectrometry (ICP-MS) provided information on the individual mercury species in plasma surrogate samples. Analogous behaviour of methylmercury and ethylmercury species in human blood was shown and an ethylmercury-glutathione adduct was identified.  相似文献   

19.
In haemostatic and biomaterial research biological processes at surfaces and in the bulk phase of the surface-contacting medium are important. The present work demonstrates the usefulness of the combination of surface plasmon resonance (SPR), sensitive to changes in refractive index at surfaces, and free oscillation rheometry (FOR), sensitive to rheological properties of the bulk, for simultaneous real-time measurements on coagulation and fibrinolysis of blood plasma and coagulation of whole blood. SFLLRN stimulated coagulation of native whole blood presented a higher SPR signal with different appearance than plasma coagulation, while the FOR signals corresponding to plasma and whole blood coagulation were similar. This indicated that the SPR technique was more sensitive to cell-surface interactions than to fibrin formation in whole blood during coagulation, while the FOR technique were equally sensitive to coagulation in whole blood and plasma. Spontaneous coagulation of native whole blood in contact with methyl- and hydroxyl-terminated self-assembled monolayers (SAM) on gold and gold surfaces regenerated after coagulation were also studied. The regenerated gold surfaces displayed the shortest coagulation times, although the contact-activation of blood coagulation for these surfaces was low. The methylated and hydroxylated surfaces were comparable in terms of coagulation activation, while the hydroxylated surfaces presented FOR signals that indicated detaching of the coagulum from the surface. The combination of SPR and FOR is well suited for studies of cell- and protein-surface interactions and simultaneous bulk processes. Possible applications are investigations of blood cell defects in patients and monitoring of native whole blood interactions with artificial surfaces.  相似文献   

20.
Platelet aggregation in platelet rich plasma and whole blood, as well as ATP secretion were studied during hypoxia in cats. A significant inhibition of collagen-induced aggregation in plasma and whole blood and ADP-induced aggregation in plasma alone with a parallel decrease of platelet ATP secretion were demonstrated. The data obtained are indicative of an important modulatory role of eicosanoids in the vascular wall interaction during hypoxia with a possible involvement of thromboxane A2.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号