首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
A novel amperometric glucose sensor was constructed by immobilizing glucose oxidase (GOD) in a titania sol-gel film, which was prepared with a vapor deposition method. The sol-gel film was uniform, porous and showed a very low mass transport barrier and a regular dense distribution of GOD. Titania sol-gel matrix retained the native structure and activity of entrapped enzyme and prevented the cracking of conventional sol-gel glasses and the leaking of enzyme out of the film. With ferrocenium as a mediator the glucose sensor exhibited a fast response, a wide linear range from 0.07 to 15 mM. It showed a good accuracy and high sensitivity as 7.2 microA cm(-2) mM(-1). The general interferences coexisted in blood except ascorbic acid did not affect glucose determination, and coating Nafion film on the sol-gel film could eliminate the interference from ascorbic acid. The serum glucose determination results obtained with a flow injection analysis (FIA) system showed an acceptable accuracy, a good reproducibility and stability and indicated the sensor could be used in FIA determination of glucose. The vapor deposition method could fabricate glucose sensor in batches with a very small amount of enzyme.  相似文献   

2.
A sensitive, selective and stable amperometric glucose biosensor employing novel PtPd bimetallic nanoparticles decorated on multi-walled carbon nanotubes (PtPd-MWCNTs) was investigated. PtPd-MWCNTs were prepared by a modified Watanabe method, and characterized by XRD and TEM. The biosensor was constructed by immobilizing the PtPd-MWCNTs catalysts in a Nafion film on a glassy carbon electrode. An inner Na?on film coating was used to eliminate common interferents such as uric acid, ascorbic acid and fructose. Finally, a highly porous surface with an orderly three-dimensional network enzyme layer (CS-GA-GOx) was fabricated by electrodeposition. The resulting biosensor exhibited a good response to glucose with a wide linear range (0.062-14.07 mM) and a low detection limit 0.031 mM. The biosensor also showed a short response time (within 5 s), and a high sensitivity (112 μA mM(-1)cm(-2)). The Michaelis-Menten constant (K(m)) was determined as 3.3 mM. In addition, the biosensor exhibited high reproducibility, good storage stability and satisfactory anti-interference ability. The applicability of the biosensor to actual serum sample analysis was also evaluated.  相似文献   

3.
A novel design and fabrication method of glucose sensors based on high aspect ratio carbon post-microarrays is reported in this paper. Apart from the fact that carbon has a wide electrochemical stability window, a major advantage of using carbon post-microarrays as working electrodes for an amperometric glucose sensor is the large reactive surface per unit footprint substrate area, improving sensitivity of the glucose sensor. The carbon post-microarrays were fabricated by carbon-microelectromechanical systems (C-MEMS) technology. Immobilization of enzyme onto the carbon post-electrodes was carried out through co-deposition of glucose oxidase (GOx) and electrochemically polymerized polypyrrole (PPy). Sensing performance of the glucose sensors with different post-heights and various post-densities was tested and compared. The carbon post-glucose sensors show a linear range from 0.5 mM to 20 mM and a response time of about 20 s, which are comparable to the simulation result. Sensitivity per unit footprint substrate area as large as 2.02 mA/(mM cm2) is achieved with the 140 μm high (aspect ratio around 5:1) carbon post-samples, which is two times the sensitivity per unit footprint substrate area of the flat carbon films. This result is consistent with the hypothesis that the number of reaction sites scales with the reactive surface area of the sensor. Numerical simulation based on enzymatic reaction and glucose diffusion kinetics gives the optimum geometric design rules for the carbon post-glucose sensor. Glucose sensors with even higher sensitivity can be achieved utilizing higher carbon post-microarrays when technology evolution will permit it.  相似文献   

4.
A voltammetric sensor for (-)-ephedrine has been prepared by a novel approach based on immobilisation of an imprinted polymer for ephedrine (MIPE) in an electrosynthesised polypyrrole (PPY) film. Composite films were grown potentiostatically at 1.0 V vs. Pt (QRE) on a glassy carbon electrode using an unconventional "upside-down" (UD) geometry for the three-electrode cell. As a consequence, a high MIP loading was obtained, as revealed by SEM. The sensor response was evaluated, after overoxidation of PPY matrix, by cyclic voltammetry after pre-concentration in a buffered solution of analyte in 0.5-3 mM concentration range. An ephedrine peak at approximately 0.9 V increasing with concentration and saturating at high concentrations was evident. PPY-modified electrode showed a response, which was distinctly lower than the MIP response for the same concentration of the template. The effect of potential interferences including compounds usually found in human fluids (ascorbic acid, uric acid, urea, glucose, sorbitol, glycine, dopamine) was examined.  相似文献   

5.
Nonenzymatic glucose oxidation is demonstrated on highly faceted palladium nanowflower-modified porous carbon electrodes fabricated by interference lithography. Varying electrodeposition parameters were used to control the final shape and morphology of the deposited nanoparticles on the 3D porous carbon which showed a 12 times increase in the electrochemically active surface area over analogous planar electrodes. Extremely fast amperometric glucose responses (achieving 95% of the steady state limiting current in less than 5s) with a linear range from 1 to 10mM and a detection limit of 10 μM were demonstrated. The unusual surface properties of the pyrolyzed photoresist films produced strongly adhered palladium crystal structures that were stable for hundreds of cycles towards glucose oxidation without noticeable current decay.  相似文献   

6.
Indirectly heated electrodes operating in a non-isothermal mode have been used as transducers for reagentless glucose biosensors. Pyrroloquinoline quinone-dependent soluble glucose dehydrogenase (PQQ-sGDH) was entrapped on the electrode surface within a redox hydrogel layer. Localized polymer film precipitation was invoked by electrochemically modulating the pH-value in the diffusion zone in front of the electrode. The resulting decrease in solubility of an anodic electrodeposition paint (EDP) functionalized with Osmium complexes leads to precipitation of the redox hydrogel concomitantly entrapping the enzyme. The resulting sensor architecture enables a fast electron transfer between enzyme and electrode surface. The glucose sensor was operated at pre-defined temperatures using a multiple current-pulse mode allowing reproducible indirect heating of the sensor. The sensor characteristics such as the apparent Michaelis constants K(M)(app) and maximum currents I(max)(app) were determined at different temperatures for the main substrate glucose as well as a potential interfering co-substrate maltose. The limit of detection increased with higher temperatures for both substrates (0.020 mM for glucose, and 0.023 mM for maltose at 48 degrees C). The substrate specificity of PQQ-sGDH is highly temperature dependent. Therefore, a mathematical model based on a multiple linear regression approach could be applied to discriminate between the current response for glucose and maltose. This allowed accurate determination of glucose in a concentration range of 0-0.1mM in the presence of unknown maltose concentrations ranging from 0 to 0.04 mM.  相似文献   

7.
An amperometric glucose biosensor with glucose oxidase (GOx) immobilized into palladium hexacyanoferrate (PdHCF) hydrogel has been prepared and evaluated. The sensor was based on a two-layer configuration with biocatalytic and electrocatalytic layers separately deposited onto the electrode. To reduce the overpotential for reduction of hydrogen peroxide liberated in the enzyme catalyzed oxidation of glucose, an inner thin layer of nickel hexacyanoferrate (NiHCF) electrodeposited onto the surface of graphite electrode was used as an electrocatalyst. As an outer layer, the hydrogel of palladium hexacyanoferrate with entrapped glucose oxidase was used. Under optimal operating conditions (pH 5.0 and E = -0.075 V versus calomel (3.0 M KCl) reference electrode), sensor showed high sensitivity to glucose (0.3-1.0 microA/mM) and a response time of less than 30s. The linear response to glucose was obtained in the concentration range between 0.05 and 1.0 mM in batch analysis mode and 0-7.0 mM in FIA. During the 32 days testing period, no significant decrease in the sensor sensitivity was observed. The sensor was applied for the determination of glucose concentration in fruit juice and yoghurt drink, and the results obtained showed good correlation with results obtained by reference spectrophotometric enzyme method.  相似文献   

8.
We report the design, construction, and testing of a contact lens with an integrated amperometric glucose sensor, proposing the possibility of in situ human health monitoring simply by wearing a contact lens. The glucose sensor was constructed by creating microstructures on a polymer substrate, which was subsequently shaped into a contact lens. Titania sol-gel film was applied to immobilize glucose oxidase, and Nafion? was used to decrease several potential interferences (ascorbic acid, lactate, and urea) present in the tear film. The sensor exhibits a fast response (20s), a high sensitivity (240 μA cm(-2) mM(-1)) and a good reproducibility after testing a number of sensors. It shows good linearity for the typical range of glucose concentrations in the tear film (0.1-0.6 mM), and acceptable accuracy in the presence of interfering agents. The sensor can attain a minimum detection of less than 0.01 mM glucose.  相似文献   

9.
For the first time glucose oxidase (GOx) was successfully co-deposited on nickel-oxide (NiO) nanoparticles at a glassy carbon electrode. In this paper we present a simple fabrication method of biosensor which can be easily operated without using any specific reagents. Cyclic voltammetry was used for electrodeposition of NiO nanoparticle and GOx immobilization. The direct electron transfer of immobilized GOx displays a pair of well defined and nearly reversible redox peaks with a formal potential (E(0')) of -0.420 V in pH 7 phosphate buffer solution and the response shows a surface controlled electrode process. The surface coverage and heterogeneous electron transfer rate constant (k(s)) of GOx immobilized on NiO film glassy carbon electrode are 9.45 x 10(-13)mol cm(-2) and 25.2+/-0.5s(-1), indicating the high enzyme loading ability of the NiO nanoparticles and great facilitation of the electron transfer between GOx and NiO nanoparticles. The biosensor shows excellent electrocatalytical response to the oxidation of glucose when ferrocenmethanol was used as an artificial redox mediator. Furthermore, the apparent Michaelis-Menten constant 2.7 mM, of GOx on the nickel oxide nanoparticles exhibits excellent bioelectrocatalytic activity of immobilized enzyme toward glucose oxidation. In addition, this glucose biosensor shows fast amperometric response (3s) with the sensitivity of 446.2nA/mM, detection limit of 24 microM and wide concentration range of 30 microM to 5mM. This biosensor also exhibits good stability, reproducibility and long life time.  相似文献   

10.
A new glucose biosensor has been fabricated by immobilizing glucose oxidase into a sol-gel composite at the surface of a basal plane pyrolytic graphite (bppg) electrode modified with multiwall carbon nanotube. First, the bppg electrode is subjected to abrasive immobilization of carbon nanotubes by gently rubbing the electrode surface on a filter paper supporting the carbon nanotubes. Second, the electrode surface is covered with a thin film of a sol-gel composite containing encapsulated glucose oxidase. The carbon nanotubes offer excellent electrocatalytic activity toward reduction and oxidation of hydrogen peroxide liberated in the enzymatic reaction between glucose oxidase and glucose, enabling sensitive determination of glucose. The amperometric detection of glucose is carried out at 0.3 V (vs saturated calomel electrode) in 0.05 M phosphate buffer solution (pH 7.4) with linear response range of 0.2-20 mM glucose, sensitivity of 196 nA/mM, and detection limit of 50 microM (S/N=3). The response time of the electrode is < 5s when it is stored dried at 4 degrees C, the sensor showed almost no change in the analytical performance after operation for 3 weeks. The present carbon nanotube sol-gel biocomposite glucose oxidase sensor showed excellent properties for the sensitive determination of glucose with good reproducibility, remarkable stability, and rapid response and in comparison to bulk modified composite biosensors the amounts of enzyme and carbon nanotube needed for electrode fabrication are dramatically decreased.  相似文献   

11.
The present communication demonstrates a relatively green preparative route toward Au nanoplates in aqueous solution at room temperature with the use of tannic acid (TA), which is an environmentally friendly, soluble polyphenol, as a reducing agent. Such Au nanoplates exhibit notable catalytic performance toward the oxidation and reduction of H(2)O(2). A glucose biosensor was further fabricated by immobilizing glucose oxidase (GOD) into chitosan-Au nanoplate composites film on the surface of glassy carbon electrode (GCE). This sensor exhibits good response to glucose, and the linear response range is estimated to be from 2 to 20 mM (R=0.999) at 0.65 V and from 2 to 10 mM (R=0.993) at -0.2 V, respectively. The sensitivity of the sensor determined from the slopes is 49.5 μA mM(-1)cm(-2) at 0.65 V.  相似文献   

12.
The in-vivo behaviour of microfabricated GOD (glucose oxidase)/H2O2 glucose sensor implanted subcutaneously in normal anaesthetized rats has been studied. The sensor consists of a planar, three-electrode microcell, an enzyme membrane (glucose oxidase and bovine serum albumin cross-linked with glutaraldehyde) and an outer diffusion limiting polyurethane membrane. The sensor behaviour during hyperglycaemic (13.8 mM and 11.2 mM), euglycaemic (7.8 mM) and hypoglycaemic (3.5 mM) plateau levels was determined. The values of the in-vivo sensitivity (0.64 +/- 0.05 nA/mM) and background current (1.25 +/- 0.4 nA) were determined using a two-point calibration method and then used to calculate apparent subcutaneous glucose concentrations. The results show the presence of a good correlation between all the plasma glucose levels (G) and the apparent subcutaneous tissue concentrations (G'), with G' = 0.997.G - 0.066, r = 0.9782.  相似文献   

13.
Containment sensors for the determination of L-lactate and glucose   总被引:3,自引:0,他引:3  
This paper reports some new results on enzyme based silicon containment sensors. For the first time an L-lactate sensor in containment technology is presented. Through optimization of the buffer system the stability of the lactate sensor was enhanced and the linear response of over 10 mM was achieved. The glucose sensor has also been optimized for a large linear measurement range exceeding 30 mM. A two-enzyme chip with glucose and lactate sensor elements which were integrated on one silicon chip is presented. The response behaviour of the two-enzyme chip was very similar to the single chip behaviour. No cross-talking effects could be observed. A fabrication process for mass-production is described.  相似文献   

14.
Immobilization of glucose oxidase in electropolymerized polypyrrole film on the surface of a platinum wire electrode, provides a convenient sensor for flow-injection glucose determination. An upper limit of linear response for 100 microliters injected sample volume was estimated as 20 mM, whereas a 500 microliters injected sample volume gave an estimated detection limit of 0.5 mM. A simple electrode preparation procedure allows quick electrode renewal before each series of measurements.  相似文献   

15.
Platinum nanowires (PtNWs) prepared by electrodeposition method with the help of porous anodic aluminum oxide (AAO) templates have been solubilized in chitosan (CHIT) together with carbon nantubes (CNTs) to form a PtNW-CNT-CHIT organic-inorganic system. The resulting PtNW-CNT-CHIT material brings capabilities for utilizing synergic action of PtNWs and CNTs to facilitate electron-transfer process in electrochemical sensor design. The PtNW-CNT-CHIT film modified electrode offered a significant decrease in the overvoltage for the hydrogen peroxide and showed to be excellent amperometric sensors for hydrogen peroxide at -0.1 V over a wide range of concentrations, and the sensitivity is 260 microAmM-1cm-2. As an application example, by linking glucose oxidase (GOx), an amplified biosensor toward glucose was prepared. The glucose biosensor exhibits a selective determination of glucose at -0.1 V with a linear response range of 5 x 10(-6) to 1.5 x 10(-2)M with a correlation coefficient of 0.997, and response time <10s. The high sensitivity of the glucose biosensor is up to 30 microAmM-1cm-2 and the detection limit was 3 microM. The biosensor displays rapid response and expanded linear response range, and excellent repeatability and stability.  相似文献   

16.
Calcium carbonate nanoparticles (nano-CaCO3) may be a promising material for enzyme immobilization owing to their high biocompatibility, large specific surface area and their aggregation properties. This attractive material was exploited for the mild immobilization of glucose oxidase (GOD) in order to develop glucose amperometric biosensor. The GOD/nano-CaCO3-based sensor exhibited a marked improvement in thermal stability compared to other glucose biosensors based on inorganic host matrixes. Amperometric detection of glucose was evaluated by holding the modified electrode at 0.60 V (versus SCE) in order to oxidize the hydrogen peroxide generated by the enzymatic reaction. The biosensor exhibited a rapid response (6s), a low detection limit (0.1 microM), a wide linear range of 0.001-12 mM, a high sensitivity (58.1 mAcm-2M-1), as well as a good operational and storage stability. In addition, optimization of the biosensor construction, the effects of the applied potential as well as common interfering compounds on the amperometric response of the sensor were investigated and discussed herein.  相似文献   

17.
An enzymeless glucose biosensor based on polypyrrole nanofibers-supporting Au nanoparticles (Au/PPyNFs) was investigated in this study. The Au/PPyNFs heterogeneous composite materials were synthesized in-situ via hydrogen bonding interactions for the assembly of polyethyleneimine (PEI) on the surface of polypyrrole nanofibers (PPyNFs). By changing the molar ratio of PPy to HAuCl(4), Au/PPyNFs with different Au loadings were obtained. The morphology and composition of Au/PPyNFs were characterized using SEM, TEM, FTIR, XRD and XPS, respectively. The hybrids exhibited a high electrocatalytic activity toward glucose oxidation, which is prerequisite for the catalysts to be applied in amperometric glucose sensors. By using the nonenzymatic glucose sensor based on Au/PPyNFs, 0.2-13mM glucose can be detected with a sensitivity of 1.003μAcm(-2)mM(-1) and a good linearity (R(2)=0.9993) between current density and glucose concentration. The proposed glucose sensor provides a promising strategy to construct fast, sensitive, and anti-interfering amperometric sensors for early diagnosis and prevention of diabetes.  相似文献   

18.
A highly sensitive molecular-imprinted polymer sensor (MIP sensor) for ultratrace oxytetracycline (OTC) determination was prepared based on the competition reaction between template molecule OTC and glucose oxidase (GOD)-labeled OTC (GOD-OTC). Sensitivity improved dramatically due to the detection of a huge amount of enzyme catalytic production, which was inversely proportional to template molecule concentration. The MIP sensor was characterized by alternating current impedance spectroscopy and cyclic voltammetry, and its voltammetric behavior was also verified. Experimental conditions including isolation, incubation, and competition were optimized. OTC can be determined at concentrations between 0 and 4.0×10(-7) mol/L with a detection limit of 3.30×10(-10) mol/L by the differential pulse voltammetry technique. The MIP sensor showed high sensitivity, selectivity, reproducibility, and good recovery in sample determination.  相似文献   

19.
Molecular imprinted polymers (MIP) as a recognition element for sensors are increasingly of interest and MIP-quartz crystal microbalance (QCM) have started to appear in the literature. In this study, we have combined quartz crystal microbalance with MIP to prepare a sensor using the ability of glucose to chelate of copper (II) ion of methacrylamidohistidine (MAH) monomer to create ligand exchange (LE) assembled monolayer which is suitable for glucose determination. The study includes the measurement of binding interaction of molecularly imprinted QCM sensor via ligand interaction, investigation of the pH effect on frequency shift and recognition selectivity studies of glucose-imprinted polymer with respect to methyl-alpha-d-glucopyranoside and sucrose. Bmax (number of binding sites) and K(D) (dissociation constant of the metal-chelate copolymer) were also calculated using Scathard plot and the detection limit was found as 0.07 mM. MIP showed higher glucose-binding affinity than a well-known glucose binding protein, conconavalin A.  相似文献   

20.
This paper proposes a very simple procedure for preparing a biocompatible sensor based on a protein (bovine serum albumin, BSA), enzyme and vinylferrocene (VF) composite membrane modified electrode. The membrane was prepared simply by first casting vinylferrocene and then coating it with BSA and glucose oxidase immobilised with glutaraldehyde. The sensor response was independent of dissolved oxygen concentration from 3 to 10 ppm and showed good stability for serum sample measurement, unlike the commonly used BSA/enzyme modified electrode. The sensor response was almost unchanged over the measurement time (>10 h) whereas the responses of a BSA and glucose oxidase modified platinum electrode and an osmium-polyvinylpyridine wired horseradish peroxidase modified electrode (Ohara et al., 1993) fell to 68% of their initial value in a serum sample containing 10mM glucose.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号