首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel and patented procedure is described for the sonochemical fabrication of a new class of microelectrode array based sensor with electrode element populations of up to 2 x 10(5) cm(-2). For some years it has been accepted that microelectrode arrays offer an attractive route for lowering minimum limits of detection and imparting stir (convectional mass transport) independence to sensor responses; despite this no commercial biosensors, to date, have employed microelectrode arrays, largely due to the cost of conventional fabrication routes that have not proved commercially viable for disposable devices. Biosensors formed by our sonochemical approach offer unrivalled sensitivity and impart stir independence to sensor responses. This format lends itself for mass fabrication due to the simplicity and inexpensiveness of the approach; in the first instance impedimetric and amperometric sensors are reported for glucose as model systems. Sensors already developed for ethanol, oxalate and a number of pesticide determinations will be reported in subsequent publications.  相似文献   

2.
A polymer-modified sonochemically fabricated glucose oxidase microelectrode array with microelectrode population densities of up to 2.5 x 10(5) microelectrodes per square centimetres is reported. These microelectrode sensors were formed by first depositing an insulating film on commercial screen printed electrodes which was subsequently sonicated to form cavities of regular sizes in the film. Electropolymerisation of aniline at the microelectrode cavities formed polyaniline protrusions containing entrapped glucose oxidase. Chemical deposition of polysiloxane from dichlorodimethysilane was used to deposit a thin protective and diffusion mass transport controlling coating over the electrodes. The physical and electrochemical properties of these films were studied. The performance of the final glucose oxidase based microelectrode sensor array is reported.  相似文献   

3.
斑马鱼胚胎发育技术在毒性评价中的应用   总被引:24,自引:0,他引:24  
对斑马鱼(Brachydanio rerio)胚胎发育技术在环境科学领域的应用作一综述,斑马鱼胚胎毒性技术是各国际标准组织认可的标准毒性测定方法之一,属于致畸效应检验,该项技术成本低、易操作、灵敏度高,特别是具有可记录多项毒性指标的特点,并可以此判断污染物的致毒机理,斑马鱼胚胎发育过程受重金属影响较大,其中Cu的毒性最强,Hg次之,Cr最弱,有机农药中三苯基锡类(TPTA)的毒性最强,林丹次之;有机试剂中含卤素取代基和苯胺类毒性最大,这与其它毒性测定方法的结果完全一致,并表现出较高的灵敏度,特别是选用非致死性的指标,可以初步认定这对测定复合污染物毒性并分析毒物的致畸效应方面有很好的发展前景。  相似文献   

4.
The quality control for the reuse of cleaned soil from a contaminated site consisted in the determination of the main contaminants by analytical chemical methods such as GC and HPLC. Since it is not possible to analyze for all contaminants a toxicity test should be used to detect large concentrations of not routinely analyzed chemicals. The aim of the study was to develop a system for toxicity testing, which should be able to predict the toxicity of soil samples based on the concentration of chemicals in the soil and to detect toxic chemicals not analyzed by the routinely conducted soil analysis.Based upon the relative sensitivity to various contaminants as well as practical aspects such as test duration and costs the Microtox® test was favoured over the bioassays with Daphnia magna and Scenedesmus subspicatus. The Microtox® test was used to measure the toxicity of various pesticides and their major metabolites. The toxicity data of the pure compounds were used to predict the toxicity (EC50 and % inhibition of the bioluminescence reaction) of defined mixtures of chemicals in water by applying two different mathematical appriaches which are based on the additivity of the effects of the single chemicals. The predicted values were compared with the experimental data and showed good agreement.In order to be able to predict the toxicity of soil samples using the Microtox® test the soil/water partition coefficient (K d) was measured for the main contaminants. The toxicity of soil samples was predicted by calculating the concentration of the contaminants in the leachate by using the corresponding concentration in the soil and applying the K d values determined. From the calculated composition of the leachate the expected toxicity was estimated. This value was compared with the toxicity experimentally determined in the Microtox® test.  相似文献   

5.
The sensitivity of the zebrafish embryo test, a test proposed for routine waste water control, was compared with the acute fish toxicity test, in the determination of six types of waste water and ten different chemicals. The waste water was sampled from the following industrial processes: paper and cardboard production, hide tanning, metal galvanisation, carcass treatment and utilisation, and sewage treatment. The chemicals tested were: dimethylacetamide, dimethylsulphoxide, cadmium chloride, cyclohexane, hydroquinone, mercuric chloride, nickel chloride, nonylphenol, resmethrin and sodium nitrite. For many of the test substances, the zebrafish embryo test and the acute fish toxicity test results showed high correlations. However, there were certain environmentally-relevant substances for which the results of the zebrafish embryo test and the acute fish toxicity test differed significantly, up to 10,000-fold (Hg(2+) > 150-fold difference; NO(2)(-) > 300-fold; Cd(2+) > 200-fold; resmethrin > 10,000-fold). For the investigated waste water samples and chemicals, the survival rate of the zebrafish embryos showed high variations between different egg samples, within the range of the EC50 concentration. Subsequently, 5-6 parallel assays were deemed to be the appropriate number necessary for the precise evaluation of the toxicity of the test substances. Also, it was found that the sensitivities of different ontogenetic stages to chemical exposure differed greatly. During the first 12 hours after fertilisation (4-cell stage to the 5-somite stage), the embryos reacted most sensitively to test substance exposure, whereas the later ontogenetic stages showed only slight or no response, indicating that the test is most sensitive during the first 24 hours post-fertilisation.  相似文献   

6.
Four wastewater samples of different treatment qualities; untreated, alarm, alert and normal, from a Swedish chemi-thermo-mechanical pulp mill and pure water were investigated using an amperometric bio-electronic tongue in a batch cell. The aim was to explore enzymatically modified screen-printed amperometric sensors for the discrimination of wastewater quality and to counteract the inherent drift. Seven out of eight platinum electrodes on the array were modified with four different enzymes; tyrosinase, horseradish peroxidase, acetyl cholinesterase and butyryl cholinesterase. At a constant potential the current intensity on each sensor was measured for 200s, 100s before injection and 100s after injection of the sample. The dynamic biosensor response curves from the eight sensors were used for principal component analysis (PCA). A simple baseline and sensitivity correction equivalent to multiplicative drift correction (MDC), using steady state intensities of reference sample (catechol) recordings, was employed. A clear pattern emerged in perfect agreement with prior knowledge of the samples explaining 97% of the variation in the data by two principal components (PCs). The first PC described the treatment quality of the samples and the second PC described the difference between treated and untreated samples. Horseradish peroxidase and pure platinum sensors were found to be the determinant sensors, while the rest did not contribute much to the discrimination. The wastewater samples were characterized by the chemical oxygen demand (COD), biological oxygen demand (BOD), total organic carbon (TOC), inhibition of nitrification, inhibition of respiration and toxicity towards Vibrio fischeri using Microtox, the freshwater alga Pseudokirchneriella subcapita and the freshwater crustacean Daphnia magna.  相似文献   

7.
8.
Responses of three groups of neural fibers from the chorda tympani of the hamster to binary mixtures of taste stimuli applied to the tongue were analyzed. The groups displayed different sensitivities to six chemicals at concentrations that had approximately equal effects on the whole nerve. Sucrose-best fibers responded strongly only to sucrose and D-phenylalanine. NaCl-best and HCl-best fibers, responded to four electrolytes: equally to CaCl2 and nearly equally to HCl, but the former responded more to NaCl, and the latter responded more to NH4Cl. The groups of fibers dealt differently with binary mixtures. Sucrose- best fibers responded to a mixture of sucrose and D-phenylalanine as if one of the chemicals had been appropriately increased in concentration, but they responded to a mixture of either one and an electrolyte as if the concentration of sucrose or D-phenylalanine had been reduced. NaCl- best fibers responded to a mixture as if it were a "mixture" of two appropriate concentrations of one chemical, or somewhat less. But, responses of HCl-best fibers to mixtures were greater than that, approaching a sum of responses to components. These results explain effects on the whole nerve, suggest that the sensitivity of a mammalian taste receptor to one chemical can be affected by a second, which may or may not be a stimulus for that receptor, and suggest that some effects of taste mixtures in humans may be the result of peripheral processes.  相似文献   

9.
A study aimed at the characterization of five compounds with different chemical characteristics and gustative perceptions by measuring the variations of the electrical impedance of a composite sensor array is presented. The array was composed of five sensors of three different types based on carbon nanotubes or carbon black dispersed in polymeric matrices and doped polythiophenes. Measurements were carried out by evaluating the electrical impedance of the sensor array at a frequency of 150 Hz, and the data acquisition process was automated; a mechanical arm and a rotating platform controlled by a data acquisition card and a dedicated software allowed the sequential dipping of sensors in the test solutions. Fifty different solutions eliciting the 5 basic tastes (sodium chloride, citric acid, glucose, glutamic acid and sodium dehydrocholate for salty, sour, sweet, umami and bitter, respectively) at 10 concentration levels comprising the human perceptive range were analysed. More than 100 measurements were carried for each sample in a 4-month period to evaluate the system repeatability and robustness. The impedentiometric composite sensor array is shown to be sensitive, selective and stable for use in an electronic tongue.  相似文献   

10.
A technique has been developed to determine the efficiency and the selectivity of a single neuron-based sensor in identifying the nature of the chemical agents in an unknown sample. This has been achieved by exploiting the unique electrical identifiers, also known as "signature patterns", generated by the neuronal cell membrane. These were generated based on the variations to the extracellular electrical activity, due to the effect of a broad range of chemical agents. We demonstrate the prediction capability of the sensor in identifying the nature of an unknown test sample from a combination of three chemical agents, namely, ethanol, pyrethroid, and hydrogen peroxide. This was achieved through a two-step process. The first step was experimentally achieved by in situ recording of the changes to the extracellular electrical activity from the sensing sites or the array of microelectrodes that form the platform for patterning neurons. Simultaneous optical characterization of the cell array during the sensing process was performed to identify the associated physiological changes. The second step was mathematical and was based on developing a library of signature patterns for a set of concentrations of the various combinations of the three chemical agents. Two variants of the nearest neighbor algorithm scheme - (a) partial distance search method, and (b) search tree method, were implemented for the accurate detection of all the components with varying concentrations in the test samples of unknown nature. This technique exhibits reliability in identification up to parts-per-billion (ppb) sensitivity. The capability of standardization of this technique for potential commercial applications is also discussed.  相似文献   

11.
Films of DNA, enzymes, polyions, and catalytic redox polyions of nanometer thickness on electrodes can provide active elements for sensors for screening the toxicity of chemicals and their metabolites, and for oxidative stress. The unifying feature of this approach involves layer-by-layer electrostatic assembly of films designed to detect DNA damage. Films containing DNA and enzymes enable detection of structural damage to DNA as a basis for toxicity screening. These films bioactivate chemicals to their metabolites, which can then react with DNA, mimicking toxicity pathways in the human liver. Metallopolyions that catalyze DNA oxidation can be incorporated into DNA/enzyme films leading to "reagentless" sensors. These sensors are suitable for detecting relative DNA damage rates in <5 min of the enzyme reactions. Films of the osmium polymer [Os(bpy)(2)(PVP)(10)Cl](+) [poly(vinylpyridine), PVP] can be used to monitor DNA oxidation selectively. Such films may be applicable to determination of oxidized DNA as a clinical biomarker for oxidative stress. Inclusion of the analogous ruthenium metallopolymer in the sensor provides a monitor for oxidation of other nucleobases.  相似文献   

12.
We have developed a direct toxicity assay for soils, sediments and sludges that is specific for heavy‐metal toxicity. In the assay, a β‐galactosidase‐producingstrain of Escherichia coll is mixed with the solids sample together with a small volume (1.0 ml/0.5 to 1.0 g of solids) of eluent Extraction of metals from the solids sample is not required. Controls run with the assay eliminate interference due to indigenous β‐ga‐lactosidase activity or interaction between the solid matrix and the chromaphore. Use of 0.1 M sodium nitrate as eluent was found to yield somewhat higher sensitivity to heavy metals in solid‐phase samples than MilliQ water. Application of the assay to a diverse array of soils, sludges, and sediments indicated that samples from industrial sites were generally more toxic than those from residential or commercial sites. Heavy‐metal toxicity was correlated with the copper and zinc content of solids samples, but toxicity varied considerably at the lower range of metal contents. The proposed solid‐phase assay should prove useful as a screening test for heavy‐metal toxicity in soils, sediments, and sludges. It can also help distinguish between heavy metals and organic chemicals as the cause of toxicity in solid‐phase samples.  相似文献   

13.
Many evaluations estimating safe levels of hydrophobic organic chemicals in sediments do not account for confounding factors such as physical habitat quality or covariance among chemicals. Controlled experiments demonstrating cause and effect can be conducted with spiked sediment toxicity tests, but application of this methodology has been limited in part by concerns about chemical bioavailability and challenges in achieving target concentrations. Relevant literature was reviewed to assess the utility of standardizing sediment equilibration times; hydrophobicity, complex sediment characteristics, and temperature were identified as potentially equally important factors. Disequilibrium appears likely following limited equilibration time but should yield conservative toxicity test results relative to aged field sediments. Nominal and measured concentrations in over 20 published studies were compared to assess spiked chemical recovery (i.e., measured concentration/nominal concentration). Recovery varied substantially among studies and was not readily predictable based on spiking or extraction method, chemical properties, or measured sediment characteristics, although unmeasured differences between sediments appeared to be important. Factors affecting specific studies included chemical adsorption to glassware, biodegradation, and volatilization. Pre- and post-toxicity test analyses are recommended to confirm exposure concentrations. Studies with 2,3,7,8-tetrachloro-dibenzo-p-dioxin (2,3,7,8-TCDD) and hexachlorobenzene (HCB) exemplify the utility of verifying results of field studies using spiked sediment tests. Sediments spiked with these chemicals at concentrations greatly exceeding those in associated field studies caused no adverse effects in test organisms, demonstrating that other chemicals co-occurring in test sediment samples caused toxicity initially attributed to 2,3,7,8-TCDD and HCB in the field studies. Another key application of spiked sediment tests has been the investigation of TOC as the primary factor affecting bioavailability of hydrophobic organic chemicals. A review of LC50s for nine chemicals reported in 12 studies shows that comparable LC50s derived in different sediments generally agree within a factor of five when concentrations are normalized to a constant TOC. Additionally, use of spiked sediment toxicity testing to investigate toxicological interactions among chemicals provides a promising approach to improving the ability to predict sediment toxicity in the field.  相似文献   

14.
Experimental and theoretical study of sensors based on enhanced transmission through periodic metal nanoslits is presented. Our approach consists of the design of one-dimensional nanoslits array and its application in sensing for water quality control. Rigorous coupled waves analysis was used for the design and fit to the experimental data. Two types of surface plasmon resonance excitations are shown to be possible, one at the upper grating–analyte interface and one at the lower grating–substrate interface. This latter resonance is shown to be affected by the multiple interference or cavity-type effects. Those structures were fabricated by deposition of the metal layer and electron beam lithography of the nanostructure. We found that Ag-based periodic array exhibits the highest sensitivity to refractive index variations. Sensitivity enhancement was measured by ethanol concentrations in water. Stability of the Ag-based sensor was improved by covering the grating with less than 15 nm polymethyl methacrylate capping layer without deterioration of the sensitivity.  相似文献   

15.
A hybrid multi-walled carbon nanotube (MWCNT) based chemical sensor was designed and developed by integration of microfabrication techniques with nano-assembly. This integrated sensing mechanism on a chip, comprised of thiol functionalized MWCNTs that functioned as transducers which were integrated with micro-electrode array measurement sites. The detection of the four fundamental hydrocarbons belonging to the aliphatic hydrocarbon family--methanol, ethanol, propanol and butanol was experimentally demonstrated. High degree of selectivity was demonstrated by repeated robust identification of individual hydro carbons belonging to the same family. The sensor demonstrated 1 ppm detection sensitivity. The detection mechanism was based on nano-scale transduction of the detection of the localized binding event between the functional binding sites and the chemical species of interest. Specific electrical signatures for each of these chemicals were identified using multiple levels of data analysis comprising of Fast Fourier Transformation (FFT) and Power Spectral Density (PSD). The sensor demonstrated a rapid response time with portability, accuracy and versatility for the in situ detection of multiple chemical agents, with potential for automation.  相似文献   

16.
The use of a multisensor array based on chemical gas sensors to monitor plant cell cultures is described. The multisensor array, also referred to as an electronic nose, consisted of 19 different metal oxide semiconductor sensors and one carbon dioxide sensor. The device was used to continuously monitor the off-gas from two plant cell suspension cultures, Morinda citrifolia and Nicotiana tabacum, cultivated under batch conditions. By analyzing the multiarray responses using two pattern recognition methods, principal component analysis and artificial neural networks, it was possible to monitor the course of the cultivations and, in turn, to predict (1) the biomass concentration in both systems and (2) the formation of the secondary metabolite, antraquinone, by M. citrifolia. The results identify the multisensor array method as a potentially useful analytical tool for monitoring plant process variables that are otherwise difficult to analyze on-line.  相似文献   

17.
In the last decade, the occurrence of harmful dinoflagellate blooms of the genus Ostreopsis has increased both in frequency and in geographic distribution with adverse impacts on public health and the economy. Ostreopsis species are producers of palytoxin-like toxins (putative palytoxin and ovatoxins) which are among the most potent natural non-protein compounds known to date, exhibiting extreme toxicity in mammals, including humans. Most existing toxicological data are derived from in vivo mouse assay and are related to acute effects of pure palytoxin, without considering that the toxicity mechanism of dinoflagellates can be dependent on the varying composition of complex biotoxins mixture and on the presence of cellular components.In this study, in vitro neuronal networks coupled to microelectrode array (MEA)-based system are proposed, for the first time, as sensitive biosensors for the evaluation of marine alga toxicity on mammalian cells. Toxic effect was investigated by testing three different treatments of laboratory cultured Ostreopsis cf. ovata cells: filtered and re-suspended algal cells; filtered, re-suspended and sonicated algal cells; conditioned growth medium devoid of algal cells. The great sensitivity of this system revealed the mixture of PTLX-complex analogues naturally released in the growth medium and the different potency of the three treatments to inhibit the neuronal network spontaneous electrical activity. Moreover, by means of the multiparametric analysis of neuronal network activity, the approach revealed a different toxicity mechanism of the cellular component compared to the algal conditioned growth medium, highlighting the potential active role of the first treatment.  相似文献   

18.
Utilization of polymers as insulator and bulk materials of microelectrode arrays (MEAs) makes the realization of flexible, biocompatible sensors possible, which are suitable for various neurophysiological experiments such as in vivo detection of local field potential changes on the surface of the neocortex or unit activities within the brain tissue. In this paper the microfabrication of a novel, all-flexible, polymer-based MEA is presented. The device consists of a three dimensional sensor configuration with an implantable depth electrode array and brain surface electrodes, allowing the recording of electrocorticographic (ECoG) signals with laminar ones, simultaneously. In vivo recordings were performed in anesthetized rat brain to test the functionality of the device under both acute and chronic conditions. The ECoG electrodes recorded slow-wave thalamocortical oscillations, while the implanted component provided high quality depth recordings. The implants remained viable for detecting action potentials of individual neurons for at least 15 weeks.  相似文献   

19.
An immersible manometric sensor was made by covering the gaseous cavity of a pressure transducer with a 1 microm controlled pore membrane. Transfer of gas across the membrane allowed the pressure transducer to record changes in humidity or dissolved gas when immersed in solution. By immersing the sensor in distilled water, atmospheric humidity could be estimated by the deficit of atmospheric vapor pressure from saturation. In another application of the sensor, CO(2) was monitored continuously. This was not possible in previous closed-reactor type manometric sensors, and may allow the new technology to be used in applications requiring continuous monitoring of a process or stream. By coupling the sensor with enzymes liberating or consuming dissolved gas, different chemicals could be estimated. Urea was estimated by first hydrolyzing it with urease and then measuring the resulting CO(2) gas in solution. Glucose was measured through its enzymatic oxidation by glucose oxidase. The sensitivity to urea over the range 0-2.5 mM was about 1.02 kPa/mM, and the standard error was 0.086 mM. Due to the lower solubility of oxygen, the sensitivity to glucose in a range from 0 to 10 microM was over 100 kPa/mM, with a standard error of only 0.76 microM. This sensitivity was not possible in closed-reactor type manometric sensors due to constraints of dimensioning the head space gas volume for reproducibility and effective mass transfer. The 90% rise times for the sensor ranged from about 1-60 min for the different applications. The dynamic characteristics of the device may be improved by using a membrane with greater porosity, higher rigidity and lower thickness, and by reducing the dimensions of the cavity volume in the sensor through integrated microfabrication of the membrane onto the transducer.  相似文献   

20.
Currently there is a surge of interest in exploiting toxicogenomics to screen the toxicity of chemicals, enabling rapid and accurate categorisation into classes of defined mode-of-action (MOA), and prioritising chemicals for further testing. Direct infusion FT-ICR mass spectrometry-based metabolomics can provide a sensitive and unbiased analysis of metabolites in only 15 mins and therefore has considerable potential for chemical screening. The water flea, Daphnia magna, is an OECD test species and is utilised internationally for toxicity testing. However, no metabolomics studies of this species have been reported. Here we optimised and evaluated the effectiveness of FT-ICR mass spectrometry metabolomics for toxicity testing in D. magna. We confirmed that high-quality mass spectra can be recorded from as few as 30 neonates (<24 h old; 224 μg dry mass) or a single adult daphnid (301 μg dry mass). An OECD 24 h acute toxicity test was conducted with neonates at copper concentrations of 0, 5, 10, 25, 50 μg l−1. A total of 5447 unique peaks were detected reproducibly, of which 4768 were assigned at least one empirical formula and 1017 were putatively identified based upon accurate mass measurements. Significant copper-induced changes to the daphnid metabolome, consistent with the documented MOA of copper, were detected thereby validating the approach. In addition, N-acetylspermidine was putatively identified as a novel biomarker of copper toxicity. Collectively, our results highlight the excellent sensitivity, reproducibility and mass accuracy of FT-ICR mass spectrometry, and provide strong evidence for its applicability to high-throughput screening of chemical toxicity in D. magna. Electronic supplementary material  The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号