首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In many cell systems, electric pulses can efficiently mediate gene transfer with a high level of expression in vitro. In vivo results have been reported where decrease in efficiency was obtained. The mechanisms involved in the process are unknown. Since, in vivo, the efficiency of non-viral methods of gene transfer is generally limited by the presence of serum, we report here the effect of serum on in vitro electrically mediated chinese hamster ovary cell membrane permeabilization, viability, gene transfer and expression. The results indicate that permeabilization and gene transfer are not inhibited by serum. By acting as a protector of cell viability, serum indeed increases gene transfer and expression.  相似文献   

2.
Cell membrane permeabilization by electric pulses (electropermeabilization), results in free exchange of ions across the cell membrane. The role of electrotransfer-mediated Ca(2+)-influx on muscle signaling pathways involved in degeneration (β-actin and MurF), inflammation (IL-6 and TNF-α), and regeneration (MyoD1, myogenin, and Myf5) was investigated, using pulse parameters of both electrochemotherapy (8 HV) and DNA delivery (HVLV). Three pulsing conditions were used: 8 high-voltage pulses (8 HV), resulting in large permeabilization and ion flux, and a combination of one high-voltage pulse and one low-voltage pulse (HVLV), either alone or in combination with injection of DNA. Mice and rats were anesthetized before pulsing. At the times given, animals were killed, and intact tibialis cranialis muscles were excised for analysis. Uptake of Ca(2+) was assessed using (45)Ca as a tracer. Using gene expression analyses and histology, we showed a clear association between Ca(2+) influx and muscular response. Moderate Ca(2+) influx induced by HVLV pulses results in activation of pathways involved in immediate repair and hypertrophy. This response could be attenuated by intramuscular injection of EGTA reducing Ca(2+) influx. Larger Ca(2+) influx as induced by 8-HV pulses leads to muscle damage and muscle fiber regeneration through recruitment of satellite cells. The extent of Ca(2+) influx determines the muscular response to electrotransfer and, thus, the success of a given application. In the case of electrochemotherapy, in which the objective is cell death, a large influx of Ca(2+) may be beneficial, whereas for DNA electrotransfer, muscle recovery should occur without myofiber loss to ensure preservation of plasmid DNA.  相似文献   

3.
Electropermeabilization is a nonviral method successfully used to transfer genes into cells in vitro as in vivo. Although it shows promise in field of gene therapy, very little is known on the basic processes supporting the DNA transfer. The aim of the present investigation is to visualize gene electrotransfer and expression both in vitro and in vivo. In vitro studies have been performed by using digitized fluorescence microscopy. Membrane permeabilization occurs at the sides of the cell membrane facing the two electrodes. A free diffusion of propidium iodide across the membrane to the cytoplasm is observed in the seconds following electric pulses. Fluorescently labeled plasmids only interact with the electropermeabilized side of the cell facing the cathode. The plasmid interaction with the electropermeabilized cell surface is stable over a few minutes. Changing the polarity and the orientation of the pulses lead to an increase in gene expression. In vivo experiments have been performed in Tibialis Cranialis mice muscle. Electric field application lead to the in vivo expression of plasmid DNA. We directly visualize gene expression of the Green Fluorescent Protein (GFP) on live animals. GFP expression is shown to be increased by applying electric field pulses with different polarities and orientations.  相似文献   

4.
Electropermeabilization is a nonviral method used to transfer genes into living cells. Up to now, the mechanism is still to be elucidated. Since cell permeabilization, a prerequired for gene transfection, is triggerred by electric field, its characteristics should depend on its vectorial properties. The present investigation addresses the effect of pulse polarity and orientation on membrane permeabilization and gene delivery by electric pulses applied to cultured mammalian cells. This has been directly observed at the single-cell level by using digitized fluorescence microscopy. While cell permeabilization is only slightly affected by reversing the polarity of the electric pulses or by changing the orientation of pulses, transfection level increases are observed. These last effects are due to an increase in the cell membrane area where DNA interacts. Fluorescently labelled plasmids only interact with the electropermeabilized side of the cell facing the cathode. The plasmid interaction with the electropermeabilized cell surface is stable and is not affected by pulses of reversed polarities. Under such conditions, DNA interacts with the two sites of the cell facing the two electrodes. When changing both the pulse polarity and their direction, DNA interacts with the whole membrane cell surface. This is associated with a huge increase in gene expression. This present study demonstrates the relationship between the DNA/membrane surface interaction and the gene transfer efficiency, and it allows to define the experimental conditions to optimize the yield of transfection of mammalian cells.  相似文献   

5.
Electropermeabilization designates the use of electric pulses to overcome the barrier of the cell membrane. This physical method is used to transfer anticancer drugs or genes into living cells. Its mechanism remains to be elucidated. A position-dependent modulation of the membrane potential difference is induced, leading to a transient and reversible local membrane alteration. Electropermeabilization allows a fast exchange of small hydrophilic molecules across the membrane. It occurs at the positions of the cell facing the two electrodes on an asymmetrical way. In the case of DNA transfer, a complex process is present, involving a key step of electrophoretically driven association of DNA only with the destabilized membrane facing the cathode. We report here at the membrane level, by using fluorescence microscopy, the visualization of the effect of the polarity and the orientation of electric pulses on membrane permeabilization and gene transfer. Membrane permeabilization depends on electric field orientation. Moreover, at a given electric field orientation, it becomes symmetrical for pulses of reversed polarities. The area of cell membrane where DNA interacts is increased by applying electric pulses with different orientations and polarities, leading to an increase in gene expression. Interestingly, under reversed polarity conditions, part of the DNA associated with the membrane can be removed, showing some evidence for two states of DNA in interaction with the membrane: DNA reversibly associated and DNA irreversibly inserted.  相似文献   

6.
Electropermeabilization is a promising nonviral method for gene therapy. However, despite the fact that it is widely used to transfer genes into living cells, the steps that limit DNA transfer remain to be determined. Here, we report the effect of cell synchronization on membrane permeabilization and gene delivery by electric fields.Chinese hamster ovary (CHO) cells were synchronized by aphidicolin or butyrate treatment. Electro-mediated transfection of these cells was evaluated under electric field conditions leading to the same level of membrane permeabilization.Aphidicolin cell synchronization in G2/M phase leads to a slight increase in plasma membrane permeabilization but to a three-fold increase in percentage of transfected cells and to an eight-fold increase in gene expression. This increase in cell transfection is specifically due to the G2/M synchronization process. Indeed, cell synchronization in G1 phase by sodium butyrate has no effect on cell permeabilization and transfection.Our results suggest that the enhanced transfection level in G2/M phase is not simply due to enhanced permeabilization, but reinforce the statement that the melting of the nuclear membrane facilitates direct access of plasmid DNA to the nucleus.  相似文献   

7.
During standard electrochemotherapy (ECT), using a train of 1,000 V/cm amplitude rectangular pulses with 1 Hz frequency, patients experience an unpleasant sensation and slight edema. According to the patients, muscle contractions provoked by high amplitude (about 1,000 V/cm) and low repetition frequency (1 Hz) pulses are the most unpleasant and painful sensations. Recently, ECT using low voltage and higher repetition frequency (LVHF) has been shown to be an effective tool for inhibiting tumor growth. The aim of the present study was to optimize electric pulse amplitude and repetition frequency for LVHF ECT by sampling the different sets of pulse parameters on cell viability and permeabilization. In ECT, a reversible effect based on high permeabilization is desirable. For this purpose, we used bleomycin to evaluate the permeabilization of K562 and MIA-PACA2 cells caused by low voltage (50–150 V/cm) and higher repetition frequency (4–6 kHz) electric pulses. We show that the reversible effect with electropermeabilization of the cells caused by LVHF ECT is accessible; this interaction is more effective for electric pulses with 70 V/cm amplitude.  相似文献   

8.
Membrane electropermeabilization to small molecules depends on several physical parameters (pulse intensity, number, and duration). In agreement with a previous study quantifying this phenomenon in terms of flow (Rols and Teissié, Biophys. J. 58:1089-1098, 1990), we report here that electric field intensity is the deciding parameter inducing membrane permeabilization and controls the extent of the cell surface where the transfer can take place. An increase in the number of pulses enhances the rate of permeabilization. The pulse duration parameter is shown to be crucial for the penetration of macromolecules into Chinese hamster ovary cells under conditions where cell viability is preserved. Cumulative effects are observed when repeated pulses are applied. At a constant number of pulses/pulse duration product, transfer of molecules is strongly affected by the time between pulses. The resealing process appears to be first-order with a decay time linearly related to the pulse duration. Transfer of macromolecules to the cytoplasm can take place only if they are present during the pulse. No direct transfer is observed with a postpulse addition. The mechanism of transfer of macromolecules into cells by electric field treatment is much more complex than the simple diffusion of small molecules through the electropermeabilized plasma membrane.  相似文献   

9.
G Hild  M Nyitrai  J Belgyi    B Somogyi 《Biophysical journal》1998,75(6):3015-3022
Cells can be transiently permeabilized by a membrane potential difference increase induced by the application of high electric pulses. This was shown to be under the control of the pulsing buffer osmotic pressure, when short pulses were applied. In this paper, the effects of buffer osmotic pressure during electric treatment and during the following 10 min were investigated in Chinese hamster ovary cells subjected to long (ms) square wave pulses, a condition needed to mediate gene transfer. No effect on cell permeabilization for a small molecule such as propidium iodide was observed. The use of a hypoosmolar buffer during pulsation allows more efficient loading of cells with beta-galactosidase, a tetrameric protein, but no effect of the postpulse buffer osmolarity was observed. The resulting expression of plasmid coding for beta-galactosidase was strongly controlled by buffer osmolarity during as well as after the pulse. The results, tentatively explained in terms of the effect of osmotic pressure on cell swelling, membrane organization, and interaction between molecules and membrane, support the existence of key steps in plasmid-membrane interaction in the mechanism of cell electrically mediated gene transfer.  相似文献   

10.
Gene transfer using electrical pulses is a rapidly expanding field. Many studies have been performed in vitro to elucidate the mechanism of DNA electrotransfer. In vivo, the use of efficient procedures for DNA electrotransfer in tissues is recent, and the question of the implied mechanisms is largely open. We have evaluated the effects of various combinations of square wave electric pulses of variable field strength and duration, on cell permeabilization and on DNA transfection in the skeletal muscle in vivo. One high voltage pulse of 800 V/cm, 0.1 ms duration (short high pulse) or a series of four low voltage pulses of 80 V/cm, 83 ms duration (long low pulses) slightly amplified transfection efficacy, while no significant permeabilization was detected using the (51)Cr-EDTA uptake test. By contrast, the combination of one short high pulse followed by four long low pulses led to optimal gene transfer efficiency, while inducing muscle fibers permeabilization. These results are consistent with additive effects of electropermeabilization and DNA electrophoresis on electrotransfer efficiency. Finally, the described new combination, as compared to the previously reported use of repeated identical pulses of intermediate voltage, leads to similar gene transfer efficiency, while causing less permeabilization and thus being likely less deleterious. Thus, combination of pulses of various strengths and durations is a new procedure for skeletal muscle gene transfer that may represents a clear improvement in view of further clinical development.  相似文献   

11.
Role of pulse shape in cell membrane electropermeabilization   总被引:2,自引:0,他引:2  
The role of the amplitude, number, and duration of unipolar rectangular electric pulses in cell membrane electropermeabilization in vitro has been the subject of several studies. With respect to unipolar rectangular pulses, an improved efficiency has been reported for several modifications of the pulse shape: separate bipolar pulses, continuous bipolar waveforms, and sine-modulated pulses. In this paper, we present the results of a systematic study of the role of pulse shape in permeabilization, cell death, and molecular uptake. We have first compared the efficiency of 1-ms unipolar pulses with rise- and falltimes ranging from 2 to 100 μs, observing no statistically significant difference. We then compared the efficiency of triangular, sine, and rectangular bipolar pulses, and finally the efficiency of sine-modulated unipolar pulses with different percentages of modulation. We show that the results of these experiments can be explained on the basis of the time during which the pulse amplitude exceeds a certain critical value.  相似文献   

12.
An increased permeability of a cell membrane during the application of high-voltage pulses results in increased transmembrane transport of molecules that otherwise cannot enter the cell. Increased permeability of a cell membrane is accompanied by increased membrane conductivity; thus, by measuring electric conductivity the extent of permeabilized tissue could be monitored in real time. In this article the effect of cell electroporation caused by high-voltage pulses on the conductivity of a cell suspension was studied by current-voltage measurements during and impedance measurement before and after the pulse application. At the same time the percentage of permeabilized and survived cells was determined and the extent of osmotic swelling measured. For a train of eight pulses a transient increase in conductivity of a cell suspension was obtained above permeabilization threshold in low- and high-conductive medium with complete relaxation in <1 s. Total conductivity changes and impedance measurements showed substantial changes in conductivity due to the ion efflux in low-conductive medium and colloid-osmotic swelling in both media. Our results show that by measuring electric conductivity during the pulses we can detect limit permeabilization threshold but not directly permeabilization level, whereas impedance measurements in seconds after the pulse application are not suitable.  相似文献   

13.
Multiple studies have shown that bipolar (BP) electric pulses in the microsecond range are more effective at permeabilizing cells while maintaining similar cell survival rates as compared to monopolar (MP) pulse equivalents. In this paper, we investigated whether the same advantage existed for BP nanosecond-pulsed electric fields (nsPEF) as compared to MP nsPEF. To study permeabilization effectiveness, MP or BP pulses were delivered to single Chinese hamster ovary (CHO) cells and the response of three dyes, Calcium Green-1, propidium iodide (PI), and FM1-43, was measured by confocal microscopy. Results show that BP pulses were less effective at increasing intracellular calcium concentration or PI uptake and cause less membrane reorganization (FM1-43) than MP pulses. Twenty-four hour survival was measured in three cell lines (Jurkat, U937, CHO) and over ten times more BP pulses were required to induce death as compared to MP pulses of similar magnitude and duration. Flow cytometry analysis of CHO cells after exposure (at 15 min) revealed that to achieve positive FITC-Annexin V and PI expression, ten times more BP pulses were required than MP pulses. Overall, unlike longer pulse exposures, BP nsPEF exposures proved far less effective at both membrane permeabilization and cell killing than MP nsPEF.  相似文献   

14.
The blood-brain barrier, mainly composed of brain microvascular endothelial cells, poses an obstacle to drug delivery to the brain. Controlled permeabilization of the constituent brain endothelial cells can result in overcoming this barrier and increasing transcellular transport across it. Electroporation is a biophysical phenomenon that has shown potential in permeabilizing and overcoming this barrier. In this study we developed a microengineered in vitro model to characterize the permeabilization of adhered brain endothelial cells to large molecules in response to applied pulsed electric fields. We found the distribution of affected cells by reversible and irreversible electroporation, and quantified the uptaken amount of naturally impermeable molecules into the cells as a result of applied pulse magnitude and number of pulses. We achieved 81 ± 1.7% (N = 6) electroporated cells with 17 ± 8% (N = 5) cell death using an electric-field magnitude of ∼580 V/cm and 10 pulses. Our results provide the proper range for applied electric-field intensity and number of pulses for safe permeabilization without significantly compromising cell viability. Our results demonstrate that it is possible to permeabilize the endothelial cells of the BBB in a controlled manner, therefore lending to the feasibility of using pulsed electric fields to increase drug transport across the BBB through the transcellular pathway.  相似文献   

15.
The goal of this study was to determine whether ultrasound (US) exposure combined with microbubble destruction could be used to enhance non-viral gene delivery in rat C6 glioma cells. Microbubbles were prepared and gently mixed with plasmid DNA. The mixture of the DNA and microbubbles was administered to cultured C6 cells under different US/microbubble conditions. Transfection efficiency and cell viability were assessed by FACS analysis, confocal laser scanning microscopy, and Trypan blue staining. The results demonstrate that microbubble with US exposure could significantly enhance the reporter gene expression as compared with other groups. No statistical significant difference was observed in the glioma cell viability between different groups. Our in vitro findings suggest that US-mediated microbubble destruction has the potential to promote safe and efficient gene transfer into C6 cells. This non-invasive gene transfer method may be useful for safe clinical gene therapy of brain cancer without a viral vector system.  相似文献   

16.
Membrane electropermeabilization relies on the transient permeabilization of the plasma membrane of cells submitted to electric pulses. This method is widely used in cell biology and medicine due to its efficiency to transfer molecules while limiting loss of cell viability. However, very little is known about the consequences of membrane electropermeabilization at the molecular and cellular levels. Progress in the knowledge of the involved mechanisms is a biophysical challenge. As a transient loss of membrane cohesion is associated with membrane permeabilization, our main objective was to detect and visualize at the single-cell level the incidence of phospholipid scrambling and changes in membrane order. We performed studies using fluorescence microscopy with C6-NBD-PC and FM1-43 to monitor phospholipid scrambling and membrane order of mammalian cells. Millisecond permeabilizing pulses induced membrane disorganization by increasing the translocation of phosphatidylcholines according to an ATP-independent process. The pulses induced the formation of long-lived permeant structures that were present during membrane resealing, but were not associated with phosphatidylcholine internalization. These pulses resulted in a rapid phospholipid flip/flop within less than 1 s and were exclusively restricted to the regions of the permeabilized membrane. Under such electrical conditions, phosphatidylserine externalization was not detected. Moreover, this electrically-mediated membrane disorganization was not correlated with loss of cell viability. Our results could support the existence of direct interactions between the movement of membrane zwitterionic phospholipids and the electric field.  相似文献   

17.
The role of the shape of electric pulses of cell permeabilization and lysis was studied using the newly developed DPS electroporator. The effects of bipolar pulses, steep rising and falling edges in the pulses, delays between pulses, and shapes of DC signals between the edges on the lysis of bovine oocytes and the permeabilization of their cell membranes were investigated. Comparing the permeabilization rates with the lysis rates revealed a number of correlations, which make it possible to optimize the pulse shapes for achieving maximum permeabilization rates while keeping the lysis rates low. The optimization of pulse shape is essential for improving the procedure of electroporation in mammalian cloning technology.  相似文献   

18.
Optimization of electroporation for transfection of mammalian cell lines   总被引:6,自引:0,他引:6  
Electroporation can be a highly efficient method for introducing DNA molecules into cultured cells for transient expression of genes or for permanent genetic modification. However, effective transformation by electroporation requires careful optimization of electric field strength and pulse characteristics. We have used the transient expression of the firefly luciferase gene as a rapid and sensitive indicator of gene expression to describe the effects on transfection efficiency of altering electroporation field strength and shape. Using the luciferase assay, we investigated the correlation of cell viability with optimal transfection efficiency and determined the optimal parameters for a number of phenotypically distinct mammalian cell lines derived from the nervous and immune systems. The efficiency of electroporation under optimal conditions was compared with that obtained using DEAE-dextran or calcium phosphate-mediated transformation. Transfection by electroporation using square wave pulses, as opposed to exponentially decaying pulses, was found to be significantly increased by repetitive pulses. These methods improve the ability to obtain high efficiency gene transfer into many mammalian cell types.  相似文献   

19.
Cell hybridization by electrofusion on filters   总被引:5,自引:0,他引:5  
Electric field pulses induce permeabilization and associated fusogenicity in cell membranes. Electrofusion of cells is usually performed in two steps: the first is the creation of close intercellular contacts; the second is an application of electric pulses that induces membrane fusion. Very large cell contacts can be obtained by a filter aspiration method. A cell monolayer is created by controlled suction on biocompatible filter. No spontaneous fusion results. Just after filtration, electrofusion is obtained by field pulses applied parallel to the filter. Cell viability is not strongly affected and cells recover their spherical shape in the minute time range after filtration. The electrical parameters, the cell density, and the flow rate control fusion. Fusion is obtained with cells of different origins with very different adhesion properties. Hybrid cells are easily formed. This approach appears to be a very efficient method for cell hybridization with an easy-to-use protocol.  相似文献   

20.
Purpose: The newer methods of cancer treatment require new idea of drug delivery in cancer cells. Due to numerous researches electromagnetic field affect on cell function and cell membrane for possible therapeutic and drug delivery. In this article, we determined in vitro uptake of fluorescent dyes into the attached K562 cells due to time-varying magnetic field exposure. Method and material: The K562 cells were exposed to magnetic pulses via Magstim stimulator and double 70?mm coil. The strength and duration of pulses in all experiments were the same and three different frequencies of 0.25, 1 and 10?Hz pulses for 56, 112 and 28 numbers of pulses were applied (nine experimental groups) and uptake of Ly and PI was measured in each group. Result: Our results show that magnetic field can efficiently increase permeability. Among the treatment groups, the system gives the optimal permeabilization when cells are exposed to a train of 28 pulses with 1?Hz frequency.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号