首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel HPLC assay which is rapid, reproducible and sensitive has been developed for the analysis of apomorphine in plasma. The assay incorporates boldine as an internal standard, and uses solid-phase extraction on C18 mini-columns for sample clean-up and concentration, so enabling quantitation of apomorphine at 500 pg/ml using fluorescence detection (λex 270 nm, λem). The HPLC assay comprised a 25 cm-long Techopakk C18 column and a mobile phase of (0.25 M sodium dihydrogen phosphate plus 0.25% heptane sulphonic acid, to pH 3.3 with orthophosphoric acid) containing 30% (v/v) methanol and 0.003% (w/v) EDTA, run at a flow-rate of 1.5 ml/min. Calibration plots prepared in plasma were linear over the range 1–30 ng/ml, (limit of quantitation (LOQ)=490 PG/ML) with R.S.D. of 0.05% and R.E. of 5.0% at the level of 1 ng/ml. Preliminary pharmacokinetic data from two patients given apomorphine by 12 h subcutaneous infusion (patient A dose=35 mg and patient B dose=141 mg) showed apomorphine elimination from plasma to fit a two-compartment model, with initial half-lives of 8.2 and 46.6 min, elimination half-lives of 76.4 and 166.5 min and area under the plasma concentration-time curve (AUC) values of 236 and 405 ng h/ml, respectively.  相似文献   

2.
A stereoselective reversed-phase HPLC assay to quantify S-(−) and R-(+) enantiomers of propranolol and 4-hydroxypropranolol in human plasma was developed. The method involved liquid–liquid extraction for sample clean-up and employed 2,3,4,6-tetra-O-acetyl-β-glucopyranosyl isothiocyanate as a pre-column chiral derivatization reagent. The internal standard used was 4-methylpropranolol. The derivatized products were separated on an Altex C18 column using a mixture of acetonitrile–water–phosphoric acid–triethylamine (58:42:0.1:0.06 and 50:50:0.15:0.06, v/v, for propranolol and 4-hydroxypropranolol, respectively) as mobile phase. The detection of propranolol derivatives was made at λex=280 nm and λem=325 nm, and the corresponding 325 and 400 nm were used for 4-hydroxypropranolol derivatives. The assay was linear from 1 to 100 ng/ml and from 2 to 50 ng/ml using 0.5 ml of human plasma for propranolol and 4-hydroxypropranolol enantiomers, respectively. The present assay is used to quantify the enantiomers of propranolol and 4-hydroxypropranolol, respectively, in human plasma for pharmacokinetic studies.  相似文献   

3.
A sensitive stereospecific high-performance liquid chromatographic assay for the quantification of tiaprofenic acid in human plasma was developed. The procedure involved extraction of tiaprofenic acid from acidified plasma into hexane-diethyl ether (8:2, v/v). Stereospecific separation was achieved with a prepacked ga1-acid glycoprotein column without derivatization. The mobile phase consisted of 2% 2-propanol in 0.01 M phosphate buffer, pH 6.5. Tiaprofenic acid was detected at 317 nm. The limit of quantification was found to be 25 ng/ml for each enantiomer using a 0.5 ml plasma sample. The assay was reproducible and accurate to be applied to the stereoselective pharmacokinetic analysis of tiaprofenic acid in plasma. Because of photoinstability of tiaprofenic acid plasma sampling and sample extraction should be performed under light protection.  相似文献   

4.
A high-performance liquid chromatographic method was developed for the determination of a new non-narcotic analgesic, DA-5018 (I), in rat plasma, urine and bile samples, using propranolol for plasma samples and protriptyline for urine and bile samples as internal standards. The method involved extraction followed by injection of 100 μl of the aqueous layer onto a C18 reversed-phase column. The mobile phases were 5 mM methanesulfonic acid with 10 mM NaH2PO4 (pH 2.5)-acetonitrile, 70:30 (v/v) for plasma samples and 75:25 (v/v) for urine and bile samples. The flow-rates were 1.0 ml/min for plasma samples and 1.2 ml/min for urine and bile samples. The column effluent was monitored by a fluorescence detector with an excitation wavelength of 270 nm and an emission wavelength of 330 nm. The retention time for I was 4.8 min in plasma samples and 10.0 min in urine and bile samples. The detection limits for I in rat plasma, urine and bile were 20, 100 and 100 ng/ml, respectively. There was no interference from endogenous substances.  相似文献   

5.
A simple, specific and sensitive high-performance liquid chromatographic (HPLC) method was developed for the determination of rifabutin in human plasma. Rifabutin and sulindac (internal standard) are extracted from human plasma using a C8 Bond Elut extraction column. Methanol (1 ml) is used to elute the compounds. The methanol is dried down under nitrogen and reconstituted in 250 μl of mobile phase. Separation is achieved by HPLC on a Zorbax Rx C8 column with a mobile phase composed of 0.05 M potassium dihydrogen phosphate and 0.05 M sodium acetate at pH 4.0-acetonitrile (53:47, v/v). Detection is by ultraviolet absorbance at 275 nm. The retention times of rifabutin and internal standard were approximately 10.8 and 6.9 min, respectively. The assay is linear over the concentration range of 5–600 ng/ml. The quantitation limit was 5 ng/ml. Both intra-day and inter-day accuracy and precision data showed good reproducibility.  相似文献   

6.
A simple, specific and sensitive high-performance liquid chromatographic (HPLC) method was developed for the determination of rifampin in human plasma. Rifampin and sulindac (internal standard) are extracted from human plasma using a C2 Bond Elut extraction column. A 100-μl volume of 0.1 M HCl is added to the plasma before extraction to increase the retenction of the compounds on the extraction column. Methanol (1 ml) is used to elute the compounds and 0.5 ml of 3 mg/ml ascorbic acid in water is added to the final eluate to reduce the oxidation of rifampin. Separation is achieved by reversed-phase chromatography on a Zorbax Rx C8 column with a mobile phase composed of 0.05 M potassium dihydrogen phosphate-acetonitrile (55:45, v/v). Detection is by ultraviolet absorbance at 340 nm. The retention times of rifampin and internal standard are approximately 4.4 and 7.8 min, respectively. The assay is linear in concentration ranges of 50 to 35 000 ng/ml. The quantitation limit is 50 ng/ml. Both intra-day and inter-day accuracy and precision data showed good reproducibility.  相似文献   

7.
A simple, selective, sensitive and precise high-performance liquid chromatographic plasma assay for the prokinetic drug cisapride is described. Alkalinised samples of plasma (100 μl) were extracted with 1.0 ml of 10% (v/v) isopropanol in chloroform, dried, redissolved in mobile phase and injected. Chromatography was performed at 20°C by pumping a mobile phase of acetonitrile (370 ml) in pH 5.2, 0.02 M phosphate buffer (630 ml) at 1.0 ml/min through a C8 Symmetry column. Cisapride and the internal standard were detected by fluorescence monitoring at 295 nm (excitation) and 350 nm (emission), and were eluted 5 min and 8 min, respectively, after injection. Calibration plots in bovine serum albumin (3% w/v) were linear (r > 0.999) from 5 to 250 ng/ml. Intra-day and inter-day precision (C.V.) was 9.5%, or less, and the accuracy was within 5.5% of the nominal concentration over the range 8–200 ng/ml. Total assay recovery was above 82%. Endogenous plasma components, major cisapride metabolite (norcisapride), and other durgs used in neonatal pharmacotherapeutics did not interfere.  相似文献   

8.
A specific, accurate, precise and reproducible assay for the quantitation of a novel indolylpiperazine anti-migraine agent (I) in plasma from various animal species is described. The method involves addition of internal standard (I.S.) and 1.0 M sodium carbonate to the plasma sample, vortex-mixing and extraction with ethylene dichloride. The organic layer is then back-extracted in a buffer consisting of 0.1 M tetramethylammonium hydroxide (TMAH), pH 3.0 and 0.1 M (NH4)2HPO4, pH 3.0, in water. The aqueous layer is injected on to a Zorbax cyano analytical column with a mobile phase consisting of acetonitrile, methanol and water (15:5:80, v/v/v) with 0.01 M TMAH, pH 3.0 and 0.01 M (NH4)2HPO4, pH 3.0. The eluate is monitored by electrochemical detection at 0.9 V (guard cell), 0.5 V (detector 1) and 0.8 V (detector 2). The retention times of I and I.S. were 7 and 10 min, respectively. In drug-free control plasma, there were no interfering peaks seen at the retention times of I or I.S. The standard curve was linear over the concentration range of 5–500 ng/ml in rat, monkey, mouse and rabbit plasma. The lower limit of quantitation in all four matrices was 5.0 ng/ml. Within- and between-assay variability of quality control samples was less than 9% relative standard deviation and the predicted concentration of the quality control samples deviated by less than 15% from the nominal concentration. The stability of I was established for up to 36 h in the autosampler tray, up to 10 months in plasma at −20°C and up to 2 h in plasma at room temperature. The assay is validated for determination of I in plasma.  相似文献   

9.
A simple and selective ion-pair HPLC method has been developed for the analysis of clarithromycin in aqueous solutions and in gastric juice. A Hypersil ODS 5-μm (150 × 4.6 mm I.D.) column was used with a mobile phase consisting of acetonitrile-aqueous 0.05 M phosphate buffer (pH 4.6) containing 5 mM 1-octanesulphonic acid (50:50, v/v). The column temperature was 50°C and detection was by UV absorption (210 nm). The limits of detection of 50-μl samples were 0.4 μg/ml (aqueous) and 0.78 μg/ml (0.5 ml gastric juice) or better. The assay was linear in the range of 1.56 to 100 μg/ml with r2 values greater than 0.99. The recovery from the gastric juice samples was 98.5±2.9%. The method was applied successfully to determine the stability of clarithromycin in 0.01 M HCl and gastric juice.  相似文献   

10.
A gas-liquid chromatographic (GLC) assay suitable for the analysis of the cis(Z)-stereoisomer of the antipsychotic drug flupentixol in human serum or plasma was developed. The minimal quantifiable concentration was 0.5 ng/ml and the day-to-day coefficient of variation was 11.2% at 1 ng/ml and 8.7% at 10 ng/ml. Following addition of perphenazine as the internal standard (I.S.) and aqueous NaOH, samples (2 ml) are extracted with n-hexane-isoamyl alcohol (98.5:1.5, v/v) (solvent), back-extracted to 0.1 M HCl and after one washing-step and addition of aqueous NaOH again extracted into 100 μl solvent. After evaporation to dryness, the extract is reconstituted in 20 μl solvent and evaporated to approximative 10 μl. A 4-μl aliquot is injected cool on-column onto the GLC system. A gas chromatograph HP 5890 with on-column injection port, nitrogen-phosphorus detector (NPD), a HP-1 25 m × 0.32 mm I.D., 0.5 μm capillary and hydrogen (3 ml/min, automated pressure control) as the carrier gas was applied. The negative influence of light on the assay was measured and discussed. The suitability of this method for clinical pharmacokinetic studies and therapeutic drug monitoring (TDM) was determined by the analysis of serum samples of 12 schizophrenic patients.  相似文献   

11.
A rapid high-performance liquid chromatographic method has been developed to determine piromidic acid in trout muscle tissue and in urine, in the presence of nalidixic, 7-hydroxymethylnalidixic, oxolinic and pipemidic acids and cinoxacin. A Nova-Pak C18 column was used with acetonitrile–4·10−4 M oxalic acid (40:60, v/v) as the mobile phase. A post-column change of pH was made with NaOH. Fluorimetric detection at 456 nm (λex 275 nm) was used. The instrumental detection limit was 5.91 ng/ml, based on height of peak. Pretreatment of the urine samples was not necessary and fish samples were extracted with sodium hydroxide solutions and cleaned by means of an extraction with chloroform. Detection limit was 147 ng/ml for urine and 5.91 ng/g for trout muscle. Good separation without interference from any other components was obtained. Recovery was better than 87% in urine and better than 72% in trout muscle tissue.  相似文献   

12.
A high-performance liquid chromatographic method was developed for the determination of a new proton pump inhibitor, YH1885 (I), in human plasma and urine, and rat blood and tissue homogenate using fenticonazole as an internal standard. The sample preparation was simple: a 2.5 volume of acetonitrile was added to the biological sample to deproteinize it. A 50-μl aliquot of the supernatant was injected onto a C8 reversed-phase column. The mobile phase employed was methanol-0.005 M tetrabutylammonium dihydrogenphosphate (77:23, v/v), and it was run at a flow-rate of 1.0 ml/min. The column effluent was monitored using an ultraviolet detector at 270 nm. The retention times for I and the internal standard were 9.0 and 10.3 min, respectively. The detection limits for I in human plasma and urine, and in rat tissue homogenate (including blood) were 50, 100 and 100 ng/ml, respectively. The coefficients of variation of the assay (within-day and between-day) were generally low (below 8.84%) for human plasma and urine, and for rat tissue homogenate. No interferences from endogenous substances were found.  相似文献   

13.
Ebastine (CAS 90729-43-4) is an antiallergic agent which selectively and potently blocks histamine H1-receptors in vivo. A simple and sensitive high-performance liquid chromatography (HPLC) method is described for the simultaneous determination of ebastine and its two oxidized metabolites, carebastine (CAS 90729-42-3) and hydroxyebastine (M–OH), in human plasma. After a pretreatment of plasma sample by solid-phase extraction, ebastine and its metabolites were analyzed on an HPLC system with ultraviolet detection at 254 nm. Chromatography was performed on a cyano column (250×4.0 mm I.D.) at 40 °C with the mobile phase of acetonitrile–methanol–0.012 M ammonium acetate buffer (20:30:48, v/v/v) at a flow rate of 1.2 ml/min. Accurate determinations were possible over the concentration range of 3–1000 ng/ml for the three compounds using 1 ml plasma samples. The intra- and inter-day assay accuracy of this method were within 100±15% of nominal values and the precision did not exceed 12.4% of relative standard deviation. The lower limits of quantitation were 3 ng/ml for ebastine and its metabolites in human plasma. This method was satisfactorily applied to the determination of ebastine and its two oxidized metabolites in human plasma after oral administration of ebastine.  相似文献   

14.
A direct injection high-performance liquid chromatography method is described for the determination of mitomycin C (MMC) in human plasma. The stationary phase consisted of hydrophilic and hydrophobic functional groups covalently bound to silicone-coated silica beads (CAPCELL PAK MF Ph-1, 150×4.6 mm I.D., 5 μm). A mobile phase using 100% water gave a better separation of MMC from endogenous interferences as compared to a mobile phase with 12.5% acetonitrile and 2.5 mM phosphate buffer (pH 6.9). Using water as the eluent (1 ml/min) and UV detection at 365 nm, MMC was found to elute at 5.0 min with a peak width of 0.3 min, whereas endogenous interferences eluted before 3 min. Total assay time per sample was 6 min. Internal standard was not required because the recovery of MMC was nearly complete, about 90% from 20 to 5000 ng/ml. The standard curve was linear from 20 to 5000 ng/ml in plasma, and the intra- and inter-day variation was between 3 to 6%. The lower detection limit was 5 ng/ml with a 25 μl sample, which represent a two- to four-fold improvement over the 10 ng/ml detection limit by previous methods using liquid-liquid extraction and comparable sample size. The simplicity of this method, i.e., no sample extraction, no internal standard, 100% aqueous mobile phase, isocratic elution and short analysis time (6 min/sample), makes it suitable for large scale routine sample analysis, whereas its small sample volume requirement and high sensitivity are useful for pharmacokinetic studies in small animals where limited sample is available.  相似文献   

15.
A rapid and sensitive method using HPLC has been developed for the quantification of nicorandil (SG-75) in human plasma samples for routine bioequivalence studies. The sample preparation needs two liquid–liquid extractions, first with CH3Cl and HClO4 as denaturation reagent and second with addition of ethyl acetate and Na2CO3(aq). Detection wavelength was 256 nm. The obtained correlation coefficient for weighted linear curve in the range from 5.0 to 300 ng/ml was higher than 0.9950. The limit of quantitation (LOQ) was established at 5.0 ng/ml. The HPLC separation was accomplished on Nucleosil Phenyl (5 μm) stainless steel column within 7 min. The mixture of 0.01 M ammonium acetate buffer (pH 6.2) and acetonitrile 10:3 (v/v) was used as the mobile phase. The same separation method was examined on HPLC–MS system. Using this system, the LOQ was established at 1.0 ng/ml and the linearity was obtained in the range from 1.0 to 150 ng/ml.  相似文献   

16.
A reversed-phase isocratic high-performance liquid chromatographic method has been developed for the determination of AG-331, a novel thymidylate synthase inhibitor, in human serum and urine. The method involves a solid-phase extraction from C18 cartridges without addition of an internal standard. The methanol eluent is evaporated under nitrogen at 40°C, and reconstituted in mobile phase, acetonitrile-water (35:65, v/v) containing 25 mM ammonium phosphate. Separation of AG-331 was obtained on a C18 column at a flow-rate of 1 ml/min. Chromatographic signals were monitored by a photodiode-array detector at a primary wavelength of 457 nm with a bandwidth of 4.8 nm. Standard curves are linear in the range of 22–2175 ng/ml in plasma and 44–2175 ng/ml in urine, respectively. The extraction recovery ranged from 92.9–102.4%. Intra-day coefficient of variation was less than 9.5%, and inter-day coefficient of variation was less than 14.3% for an AG-331 concentration of 44 ng/ml. This method has been used to characterize the pharmacokinetics of AG-331 in cancer patients as part of ongoing Phase I trials.  相似文献   

17.
The present describes a new high-performance liquid chromatographic method with fluorescence detection for the analysis of levodropropizine [S-(−)-3-(4-phenylpiperazin-1-yl)-propane-1,2-diol] (Levotuss), an anti-tussive drug, in human serum and plasma. A reversed-phase separation of levodropropizine was coupled with detection of the native fluorescence of the molecule, using excitation and emission wavelengths of 240 nm and 350 nm respectively. The analytical column was packed with spherical 5 μm poly(styrene-divinylbenzene) particles and the mobile phase was 0.1 M NaH2PO4 pH 3-methanol (70:30, v/v), containing 0.5% (v/v) tetrahydrofuran. For quantitation, p-methoxylevodropropizine was used as the internal standard. Samples of 200 μl of either serum or plasma were mixed with 200 μl of 0.1 M Na2HPO4 pH 8.9 and extracted with 5 ml of chloroform-2-propanol (9:1, v/v). The dried residue from the organic extract was redissolved with distilled water and directly injected into the chromatograph. The limit of detection for levodropropizine, in biological matrix, was about 1–2 ng/ml, at a signal-to-noise ratio of 3. The linearity was satisfactory over a range of concentrations from 3 to 1000 ng/ml (r2 = 0.99910); within-day precision tested in the range 5–100 ng/ml as well as day-to-day reproducibility proved acceptable, with relative standard deviations better than 1% in most cases. Interferences from as many as 91 therapeutic or illicit drugs were excluded.  相似文献   

18.
A method is reported for the measurement of quercetin in human plasma using reversed-phase high-performance liquid chromatography (HPLC). Quercetin and kaempferol (as internal standard) were spiked into plasma samples and extracted using C18 Sep-Pak Light cartridges (efficiency > 85%). Flavonoids were eluted with aqueous acetone (50% v/v, pH 3.5), dried down and redissolved in aqueous acetone (45% v/v, pH 3.5). The increased osmolarity promoted a phase separation and the water-saturated acetone layer, containing the flavonoids, was analysed by HPLC with aqueous acetone mobile phase (45% v/v acetone in 250 mM sodium dihydrogen sulphate. The mixture was adjusted to pH 3.5 with phosphoric acid and used at a flow-rate of 1.0 ml/min) and μBondapak C18 column (150 × 3.9 mm I.D., 10 μm particle size). The detection limit (A375 nm) for quercetin in plasma was 0.1 μg/ml (300 nM). The method also detects metabolites of quercetin, although these are not yet identified.  相似文献   

19.
A HPLC–UV determination of clobazam and N-desmethylclobazam in human serum and urine is presented. After simple liquid–liquid extraction with dichloromethane the compounds and an internal standard diazepam were separated on a Supelcosil LC-8-DB column at ambient temperature under isocratic conditions using the mobile phase: CH3CN–water–0.5 M KH2PO4–H3PO4 (440:540:20:0.4, v/v and 360:580:60:0.4, v/v for serum and urine, respectively). The detection was performed at 228 nm with limits of quantification of 2 ng/ml for serum and 1 ng/ml for urine. Relative standard deviations for intra- and inter-assay precision were found below 8% for both compounds for all the tested concentrations. The described procedure may be easily adapted for several 1,4-benzodiazepines.  相似文献   

20.
A new high-performance liquid chromatographic method for the simultaneous determination of indinavir, saquinavir and ritonavir in human plasma is described. Quantitative recovery following liquid–liquid extraction with diethyl ether from 500 μl of human plasma was achieved. Subsequently, the assay was performed with a linear gradient starting at 67 mM potassium dihydrogenphosphate–acetonitrile (65:35 to 40:60, v/v) as a mobile phase, a Phenomenex C18 column and UV detection at 240 and 258 nm, respectively. Linear standard curves were obtained for concentrations ranging from 75 to 20 000 ng/ml for indinavir, from 10 to 6000 ng/ml for saquinavir, and from 45 to 30 000 ng/ml for ritonavir. The calculated intra- and inter-day coefficients of variation were below 6%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号