首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An HPLC column-switching method for the enantioselective determination of (R,S)-atenolol in human urine was developed and validated. Diluted urine samples were injected onto a LiChrospher ADS restricted access column and atenolol was separated from most of the matrix components using 0.01 M Tris buffer. The atenolol peak was sharpened by a step gradient of 30% acetonitrile and the atenolol-containing fraction was switched onto an enantioselective column. Separation of the atenolol enantiomers was carried out on a Chirobiotic T (Teicoplanin) column using acetonitrile–methanol–acetic acid–triethylamine (55:45:0.3:0.2, v/v/v/v) as eluent. Detection of the effluent was performed by fluorescence measurement. Several experiments were carried out to suppress the high blank reading, which was efficiently achieved using Tris buffer in the first dimension. For the enantioselective analysis of (R)- and (S)-atenolol in plasma under the same conditions the sample capacity of the ADS column is considerably lower.  相似文献   

2.
A sensitive and highly automated high-performance liquid chromatography (HPLC) column-switching method has been developed for the simultaneous determination of the active metabolite III and its prodrug II, both derivatives of the oral platelet inhibitor Ro 48-3657 (I), in plasma and urine of man and dog. Plasma samples were deproteinated with perchloric acid (0.5 M), while urine samples could be processed directly after dilution with phosphate buffer. The prepared samples were injected onto a pre-column of a HPLC column switching system. Polar plasma or urine components were removed by flushing the precolumn with phosphate buffer (0.1 M, pH 3.5). Retained compounds (including II and III) were backflushed onto the analytical column, separated by gradient elution and detected by means of UV detection at 240 nm. The limit of quantification for both compounds was 1 ng/ml (500 μl of plasma) and 25 ng/ml (50 μl of urine) for plasma and urine, respectively. The practicability of the new method was demonstrated by the analysis of about 6000 plasma and 1300 urine samples from various toxicokinetic studies in dogs and phase 1 studies in man.  相似文献   

3.
A high-performance liquid chromatographic (HPLC) method is described for the determination of apigenin and the 4′-methylated derivative acacetin in human urine using column-switching and ultraviolet (UV) absorbance detection. Urine samples were enzymatically hydrolysed and solid-phase extracted prior to injection onto the HPLC system. Prior to elution of apigenin and the internal standard, 5,7,8-trihydroxyflavone, from the first column used for sample clean-up, the six-port valve was switched to the second column for analysis with UV detection. Detection of apigenin was precise and reproducible, with a limit of quantification of 10 ng ml−1 urine. Detection and quantification of acacetin was linear down to 70 ng ml−1 urine. The method has been successfully applied to determine the level of apigenin in 100 human urine samples from an intervention study with parsley.  相似文献   

4.
The validation of a solid-phase extraction and an ion pair high-performance liquid chromatographic assay for the determination of nedocromil sodium (NCS) in urine samples following oral and inhaled administration to healthy volunteers is described. NCS and its internal standard sodium cromoglycate (SCG) were extracted from urine samples using solid-phase extraction and then quantified using high-performance liquid chromatography (HPLC). A 25-cm C8 Spherisorb 5 μm stationary phase with a mobile phase containing a long alkyl chain ion-pair reagent (methanol–0.045 M phosphate buffer–0.05 M dodecyl triethyl ammonium phosphate; 550:447.6:2.4, v/v) was used. The mean (S.D.) intra-day accuracy and precision of the HPLC assay was 99.9 (1.6) and 7.05 (4.9)%, respectively. These values for the inter-day data were 102.4 (4.07) and 10.5 (2.7)%, respectively, over the concentration range investigated. The method described permits the detection of NCS in human urine at concentrations as low as 0.04 μg ml−1 where the signal-to-noise ratio is greater than 3:1. In 10 healthy volunteers a significantly greater amount of NCS was excreted in the urine following inhalation than after oral dosing (p<0.001). The mean (S.D.) amount of NCS renally excreted at 0.5, 1.0 and 24 h following inhalation of four 2-mg doses of NCS from a metered dose inhaler (MDI) was 0.513 (0.24), 1.163 (0.49) and 4.00 (1.73)% of the nominal dose. Similar values after oral administration of 8 mg of NCS were 0.026 (0.03), 0.079 (0.06) and 0.930 (0.74)%, respectively.  相似文献   

5.
An HPLC assay for the determination of risedronate in human urine was developed and validated. Risedronate and the internal standard were isolated from 5-ml urine samples in a two-part procedure. First, the analytes were precipitated from urine along with endogenous phosphates as calcium salts by the addition of CaCl(2) at alkaline pH. The precipitate was then dissolved in 0.05 M ethylene glycol-bis(beta-aminoethyl ether)-N,N,N',N'-tetraacetic acid and subjected to ion-pair solid-phase extraction using a Waters HLB cartridge (1 ml, 30 mg) with 1-octyltriethylammonium phosphate as the ion-pair reagent. Following extraction, the analytes were initially separated from the majority of co-extracted endogenous components on a Waters X-Terra RP18 (4.6 x 50 mm, 3.5 microm) column. The effluent from the X-Terra was "heart-cut" onto a Phenomenex Synergi Polar RP (4.6 x 150 mm, 4 microm) column for final separation. UV detection (lambda=262 nm) was used to quantitate risedronate in the concentration range of 7.5-250 ng/ml. Mean recovery was 83.3% for risedronate and 86.5% for the internal standard. The intra-day precision of the assay, as assessed by replicate (n=5) standard curves, was better than 6% RSD for all points on the standard curve. Within-day accuracy for the standards ranged from 96.3 to 106.1% of nominal. Inter-day precision for quality controls assayed over a 3-week period was better than 5%, while inter-day accuracy was within 90% of nominal. The assay was employed to analyze samples collected during a clinical pharmacokinetics study.  相似文献   

6.
A work up procedure is described by which DON concentrations in blood, bile, urine and excrements from swine can be quantified by HPLC and UV- detection at λ = 220 nm. The central step thereby is the purification and concentration of DON by means of an immunoaffinity column. While, in our experiments, the quantification of DON in blood and urine was straightforward an additional purification step by a preparative HPLC run prior to immunoaffinity chromatography was needed when bile and excrements were investigated. However, when low DON concentrations in blood and urine are expected, a preparative HPLC run prior to immunoaffinity chromatography is recommended as well, because larger amounts of sample materials should be analyzed and more impurities interfere with the column proteins. In our study, using spiked samples, recoveries ranged from 75—90% and limits of detection were 0.01 to 0.02 μg/ml.  相似文献   

7.
A column-switching, reversed-phase high-performance liquid chromatographic (HPLC) method for the determination of a new carbapenem antibiotic assay using ultraviolet detection has been developed for a new carbapenem antibiotic L-749,345 in human plasma and urine. A plasma sample is centrifuged and then injected onto an extraction column using 25 mM phosphate buffer, pH 6.5. After 3 min, using a column-switching valve, the analyte is back-flushed with 10.5% methanol–phosphate buffer for 3 min onto a Hypersil 5 μm C18 BDS 100×4.6 mm analytical column and then detected by absorbance at 300 nm. The sample preparation and HPLC conditions for the urine assay are similar, except for a longer analytical column 150×4.6 mm. The plasma assay is specific and linear from 0.125 to 50 μg/ml; the urine assay is linear from 1.25 to 100 μg/ml.  相似文献   

8.
A heart-cut column-switching, ion-pair, reversed-phase HPLC system was used for the quantitation of efletirizine (EFZ) in biological fluids. The analyte and an internal standard (I.S.) were extracted from human EDTA plasma by C18 solid-phase extraction (SPE) using a RapidTrace® workstation. The eluent from the SPE was evaporated, reconstituted and injected onto the HPLC column. Urine samples were diluted and injected directly without the need of extraction. The compounds of interest were separated from most of the extraneous matrix materials by the first C18 column, and switched onto a second C18 column for further separation using a mobile phase of stronger eluting capability. Linearity range was 10–2000 ng ml−1 for plasma and 0.05–10 μg ml−1 for urine. The lower limit of quantitation (LOQ) was 10 ng from 1 ml of plasma, with a signal-to-noise ratio of 15:1. Inter-day precision and bias of quality control samples (QCs) were <5% for plasma and <7% for urine. Selectivity was established against six other antihistamines, three analogs of efletirizine, and on 12 control plasma lots and nine control urine lots. Recovery was 90.0% for EFZ and 89.5% for I.S. from plasma. One hundred samples can be processed in every 2.75 h on a 10-module RapidTrace® workstation with minimal human attention. Method ruggedness were tested on three brands of SPE and six different lots of one SPE brand. Performance ruggedness was demonstrated by different analysts on multiple HPLC systems. Analyte stability through sample storage, extraction process (benchtop, freeze–thaw, refrigeration after extraction) and chromatography (on-system, reinjection) was established.  相似文献   

9.
An assay using nonsuppressed (single-column) anion chromatography was developed to determine the concentration of inorganic sulfate in biologic fluids. A conventional HPLC system with an anion-exchange column and conductimetric detector interfaced with an automatic injector and integrator was used. The mobile phase for the chromatography of urine and serum samples is 4 mM potassium hydrogen phthalate, pH 4.5, and potassium iodide is used as the internal standard. For cerebrospinal fluid samples, the mobile phase is modified by addition of 10% of a 4 mM phthalic acid solution. Results of the HPLC assay were found to correlate well (r = 0.991 and 0.999) with those of two commonly used spectrophotometric methods for urine and serum inorganic sulfate determinations. However, the concentrations determined by ion chromatography were 2.5 to 10% lower, possibly due to less assay interference by other substances following chromatographic separation of sulfate. Anion chromatography using a single-column system is a convenient and relatively inexpensive method with sufficient sensitivity for the determination of inorganic sulfate concentrations in urine, serum, and cerebrospinal fluid.  相似文献   

10.
A novel high-performance liquid chromatography (HPLC) assay for the estimation of formoterol in urine samples was developed and validated. A solid phase extraction (SPE) using Oasis HLB was optimised to isolate formoterol from a urine matrix followed by HPLC with UV detection. This extraction procedure concentrated the final analyte forty times so that UV detection can be used to determine even a low concentration of formoterol in urine samples. The urinary assay was performed in accordance with FDA and ICH regulations for the validation of bioanalytical samples. The samples were injected onto a C18 Spherisorb (250 mm x 4.6 mm x 5 microm) analytical column maintained at 30 degrees C. The mobile phase consisted of 5 mM of potassium dihydrogen orthophosphate buffer (adjusted to pH 3 with ortho phosphoric acid):acetonitrile (ACN) (70:30, v/v), and the formoterol peak was detected at wavelength 214 nm. The extraction recovery of formoterol from the urine sample was >95%. The calibration curve was linear (r2=0.99) over formoterol concentrations ranging from 1.5 to 25 ng/mL (n=6). The method had an accuracy of >92% and intra and inter-day precision CV% of <3.9% and <2.2%, respectively, at three different concentrations low, medium and high (10, 15, 20 ng/mL). The limit of quantification (LOQ) for formoterol was found to be 1.50 ng/mL. The accuracy and precision at the LOQ level were 95% and %CV <3.7% (n=10), respectively. The method reported is simple, reliable, precise, and accurate and has the capacity to be used for determination of formoterol in urine samples.  相似文献   

11.
An automated method, based on column-switching reversed-phase high-performance liquid chromatography, has been developed for the determination of a major metabolite of tipredane in rat urine. Samples are injected directly onto a cyanopropyl extraction column. The portion of eluate containing the metabolite is switched, via an injection loop, onto an octadecylsilane analytical column. The limit of quantification of the method was 25 ng/ml for a 20 μl injection volume of urine. The intra-assay precision (0.7–4.8%) and accuracy (94–105%), and the inter-assay precision (2.7–12.6%) and accuracy (94–105%), were acceptable. The analyte was found to be stable in rat urine when stored at room temperature for six days, in a freezer at or below −20°C for twelve weeks, and when the samples were subjected to two freeze–thaw cycles. No significant interference was observed from tipredane and its major human metabolites, or urine constituents in male and female rats. The method was successfully used to analyse samples from a long-term toxicology study.  相似文献   

12.
A sensitive column-switching high-performance liquid chromatography (HPLC) with ultraviolet (UV) detection was developed for the determination of propiverine in human plasma. Propiverine and internal standard, oxybutynin, were extracted from human plasma that had been made basic with 5N sodium hydroxide into methyl tert-butyl ether. The extracted plasma sample was injected onto the HPLC system consisting of a pretreatment column, a concentrating column, and an analytical column, which were connected with a six-port switching valve. The assay was linear in concentration ranges of 2-200 ng/ml for propiverine in human plasma. This method showed excellent sensitivity (a limit of detection of 0.5 ng/ml), good precision and accuracy. This method is suitable for bioequivalence studies following single dose in healthy volunteers.  相似文献   

13.
A fast method is described for the screening of eleven β-blockers, two narcotic analgesics and two stimulants in urine by HPLC with column switching. The urine sample (100 μl), buffered tto pH 9–9.5, is injected onto a short extraction column packed with CN stationary phase. The extraction is flushed with water for 2.5 min to elute polar matrix components to waste. The retained components are then backflushed by means of a six-port valve onto the ODS analytical column where they are separated. Phosphate buffer pH 3.0 and acetonitrile were used as mobile phase. Gradient elution was applied in the screening method to improve separation. Detection was performed with diode-array detector at 220, 235 and 300 nm. Recoveries were near 100%, precision was excellent and sensitivity about 0.25 μg/1. The speed up the quantitative analysis, the same method but with isocratic elution was successfully applied to the determination of acebutolol and metoprolol in urine samples collected 4 h after administration of the compounds as single doses.  相似文献   

14.
A column-switching high-performance liquid chromatographic method has been developed for the simple and sensitive analysis of BO-2727 (I) in human plasma and urine. Plasma samples were diluted with an equal volume of a stabilizer, and the mixture was directly injected onto the HPLC system. The analyte was enriched in a pre-treatment column, while endogenous components were eluted to waste. The analyte was then backflushed onto an analytical column and quantified with ultraviolet detection. Urinary concentrations were determined in a similar way except that the enriched analyte was eluted in the foreflush mode to a cation-exchange column used for chromatographic separation. The standard curves for the drug were linear in the range of 0.05–50 μg/ml in plasma and 0.5–100 μg/ml in urine. The limits of quantification for plasma and urine were found to be 0.05 μg/ml and 0.5 μg/ml, respectively. This method was used to support Phase I clinical pharmacokinetic studies.  相似文献   

15.
We examined the effects of nedocromil sodium, a new drug developed for the treatment of reversible obstructive airway disease, on allergen-induced early and late bronchial responses and the development of airway hyperresponsiveness 24 h after challenge in nine allergic sheep. On occasions greater than 2 wk apart the sheep were treated with 1) placebo aerosol (buffered saline) before and 3 h after antigen challenge, 2) an aerosol of nedocromil sodium (1 mg/kg in 3 ml buffered saline) before antigen challenge and placebo 3 h after challenge, and 3) placebo aerosol before and nedocromil sodium aerosol 3 h after challenge. Early and late bronchial responses were determined by measuring specific lung resistance (sRL) before and periodically after challenge. Airway responsiveness was assessed by determining from dose-response curves the carbachol concentration (in % wt/vol) that increased sRL to 5 cmH2O/s. In the placebo trial, antigen challenge resulted in early and late increases in sRL over a base line of 353 +/- 32 and 131 +/- 17% (SE), respectively. Both early and late increases in sRL were blocked (P less than 0.05) when the sheep were pretreated with nedocromil sodium. When nedocromil was given after the early response, the late response was reduced significantly. Eight of nine sheep developed airway hyperresponsiveness 24 h after antigen challenge. In these eight sheep, carbachol concentration before antigen challenge was 2.6 +/- 0.3%, 24 h later carbachol concentration was significantly lower (1.8 +/- 0.3%). Both nedocromil sodium treatments blocked (P less than 0.05) this antigen-induced airway hyperresponsiveness.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

16.
A HPLC method was developed for determination of cimetidine in human plasma and urine. Plasma samples were alkalinized followed by liquid extraction with water-saturated ethyl acetate then evaporated under nitrogen. The extracts were reconstituted in mobile phase and injected onto a C(18) reversed-phase column; UV detection was set at 228 nm. Urine samples were diluted with an internal standard/mobile phase mixture (1:9) prior to injection. The lower limit of quantification in plasma and urine were 100 ng/ml and 10 microg/ml, respectively; intra- and inter-day coefficients of variation were 相似文献   

17.
A method for the determination of 8-oxo-2'-deoxyguanosine and 8-oxo-2'-deoxyadenosine in DNA and urine by High Performance Liquid Chromatography (HPLC)-Tandem Mass Spectrometry is described. For the urine samples there is no sample preparation except for addition of buffer and internal standards followed by redissolvation of precipitate containing 8-oxo-2'-deoxyguanosine and a centrifugation step before the samples are injected onto the HPLC column. The detection limit for 8-oxo-2'-deoxyguanosine and 8-oxo-2'-deoxyadenosine is approximately 0.3 nM corresponding to 7.5 fmol injected. Long runs, that is, > 50 samples, can be analyzed with only minimal loss of sensitivity. The concentrations excreted into urine samples from humans are between 1 and 100 nM for 8-oxo-2'-deoxyguanosine and below 0.3 nM for 8-oxo-2'-deoxyadenosine. In calf thymus DNA levels down to about 1 oxidized guanosine and adenosine per 10(6) unmodified bases can be detected. High levels of 8-oxo-2'-deoxyguanosine were found, 30 per 10(6) 2'-deoxyguanosine, levels of 8-oxo-2'-deoxyadenosine are at or below the detection limit. These findings indicate that High Performance Liquid Chromatography-Tandem Mass Spectrometry is a highly sensitive and specific method for analysis of oxidative DNA modifications in tissue as well as for analysis of excretion of oxidized nucleotides into urine that ensures a minimum artifact formation.  相似文献   

18.
19.
A column-switching HPLC method using an internal-surface phenylboronic acid precolumn for the selective extraction of β-blockers from biological fluids has been developed. Filtered urine and plasma samples (50 μl) were injected onto the precolumn equilibrated with methanol-0.05 M disodium hydrogenphosphate (5:95, v/v). After the precolumn had been washed breifly, the selectively retained β-blockers were eluted with methol-0.05 M phosphate buffer (pH 2.0) and transferred to a reversed-phase analytical column, on which they were then separated. Even after exposure to at least 160 injections of non-treated urine and plasma samples, the retention efficiency of the precolumn was maintained with no increase in back pressure. Quantitative recoveries and good reproducibility were demonstrated with pindolol.  相似文献   

20.
A highly sensitive and selective high-performance liquid chromatographic assay has been developed for the separation and quantitation of tolmetin and its major metabolite in human biological fluids, viz. plasma, urine and synovial fluid. Analysis of plasma and synovial fluid required only 0.5 ml of the sample. The sample was washed with diethyl ether and extracted with diethyl ether—chloroform (2:1). The extracted compounds were injected onto a reversed-phase column (RP-2) and absorbance was measured at 313 nm. The standard curves in plasma were found to be linear for both tolmetin and the metabolite at concentrations from 0.04 to 10.0 μg/ml. Urine samples (0.5 ml) were diluted (1:1) with methanol containing the internal standard and were directly injected onto the reversed-phase (RP-2) column. Standard curves of tolmetin and metabolite in urine were linear in the range 5–300 μg/ml. Serum and synovial fluid concentrations of tolmetin and its metabolite in patients receiving multiple doses of tolmetin sodium were determined using the assay procedure.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号