首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Homogeneous assays are attractive because they are performed in only one phase, namely, the liquid phase, and thus, they do not require separation of phases as their heterogeneous counterparts do. As opposed to heterogeneous assays, the signal generation in a homogeneous assay is a direct result of analyte binding, which allows the multiple washing and incubation steps required in an indirect heterogeneous assay format to be eliminated. Moreover, homogeneous assays are usually fast and amenable to miniaturization and automation. In this article, we describe the development of a homogeneous assay for the hormone cortisol using the bioluminescent photoprotein aequorin as a reporter molecule. A cortisol derivative was chemically conjugated to the lysine residues of a genetically modified aequorin in order to prepare an aequorin-cortisol conjugate capable of binding anticortisol antibodies. The binding of anticortisol antibodies to the aequorin-cortisol conjugate resulted in a linear response reflected in the emission of bioluminescence by aequorin. A competitive binding assay was developed by simultaneously incubating the aequorin-cortisol conjugate, the anticortisol antibodies, and the sample containing free cortisol. Dose-response curves were generated relating the intensity of the bioluminescence signal with the concentration of free cortisol in the sample. The optimized homogeneous immunoassay produced a detection limit of 1 x 10 (-10) M of free cortisol, with a linear dynamic range spanning from 1 x 10 (-5) to 1 x 10 (-9) M. Both serum and salivary levels of cortisol fall well within this assay's linear range (3.0 x 10 (-7) M to 7.5 x 10 (-7) M and 1.0 x 10 (-8) M to 2.5 x 10 (-8) M, respectively), thereby making this assay attractive for the analysis of this hormone in biological samples. To that end, it was demonstrated that the assay can be reliably used to measure the concentration of free cortisol in saliva without significant pretreatment of the sample.  相似文献   

2.
Uniformly sized polymeric separation media were prepared using o- or p-xylene as porogenic template to investigate chromatographic selectivity towards tetra-chlorinated dibenzo-p-dioxins (TCDDs). TCDDs having chlorine atoms at ortho positions of phenyl rings were selectively retained on stationary phase prepared with o-xylene as porogenic template, while TCDDs having chlorine atoms at para positions of phenyl ring were found to be retained selectively on the stationary phase imprinted by the porogenic template, p-xylene. Slightly longer cross-linking agent afforded chromatographically selective retention for larger TCDD isomers. It was also found that positional relationship between substituted chlorine atoms was also important for chromatographic recognition.  相似文献   

3.
The importance of continuous beds (monoliths) as separation materials is connected with their better chromatographic properties and easier preparation in comparison to particulate-packed columns. Moreover the tuning of porosity as well as surface chemistry can lead to obtaining of highly selective materials, especially useful in separation of biologically important compounds or even microorganisms. To obtain high selectivity for such analytes as e.g. proteins, it is often important to have a knowledge about their shape, size, charge and finally charge distribution. This article presents our considerations on the charge distribution on the monolithic stationary phase and surface of such species as proteins or microorganisms as well as its eventual influence on the separation or sample preparation processes and tuning of their selectivity.  相似文献   

4.
The importance of continuous beds (monoliths) as separation materials is connected with their better chromatographic properties and easier preparation in comparison to particulate-packed columns. Moreover the tuning of porosity as well as surface chemistry can lead to obtaining of highly selective materials, especially useful in separation of biologically important compounds or even microorganisms. To obtain high selectivity for such analytes as e.g. proteins, it is often important to have a knowledge about their shape, size, charge and finally charge distribution. This article presents our considerations on the charge distribution on the monolithic stationary phase and surface of such species as proteins or microorganisms as well as its eventual influence on the separation or sample preparation processes and tuning of their selectivity.  相似文献   

5.
The aim of this study was to develop a procedure that enabled the separation of estradiol diastereoisomers. For this purpose a series of stationary phases with different surface properties has been utilized. Two of them contain various interaction sites, such as: cholesterol, n-acylamide, amine and silanols localised in the organic layer bonded to the surface of silica gel (SG-CHOL and SG-CHOL/AP). The other one contains mainly alkylamide ligands and also residual aminopropyl and silanol groups (SG-AP), as well as the last one consisting of hydrocarbonaceous material (SG-C(18)). In order to select the best type of stationary phase for this analysis, after chromatographic separation of 17-alpha-estradiol and 17-beta-estradiol, selectivity and resolution of the analytes were compared. The best separation of hormones was obtained for SG-CHOL packing, as a consequence of the structure and the properties of this stationary phase. To better understand the retention mechanism and the properties of the stationary phases, used in the separation of steroid compounds, the functional group contributions (tau) were compared with Hansch substituent constants (pi).  相似文献   

6.
The enantioseparation of ezetimibe stereoisomers by high‐performance liquid chromatography on different chiral stationary phases, ie, 3 polysaccharide‐based chiral columns, was studied. It was observed that cellulose‐based Chiralpak IC column exhibited the best resolving ability. After the optimization of mobile phase compositions in both normal and reversed phase modes, satisfactory separation could be obtained on Chiralpak IC column, especially in normal phase mode. The use of prohibited solvents as nonstandard mobile phase gave rise to better resolution than that of standard mobile phases (n‐hexane/alcohol system). In addition, the presence of ethanol in nonstandard mobile phase has played an important role in enhancing chromatographic efficiency and resolution between ezetimibe stereoisomers. Various attempts were made to comprehensively compare the chiral recognition capabilities of immobilized versus coated polysaccharide‐based chiral columns, amylose‐based versus cellulose‐based chiral stationary phases, reversed versus normal phase modes, and standard versus nonstandard mobile phases. Moreover, possible solute‐mobile phase‐stationary phase interactions were derived to explain how stationary and mobile phases affected the separation. Then the method validation with respect to selectivity, linearity, precision, accuracy, and robustness was carried out, which was demonstrated to be suitable and accurate for the quantitative determination of (RRS)‐ezetimibe impurity in ezetimibe bulk drug.  相似文献   

7.
G T?r?k  A P?ter  D W Armstrong  D Tourw?  G T?th  J S?pi 《Chirality》2001,13(10):648-656
Direct high-performance liquid chromatographic chiral separation of numerous underivatized unnatural amino acids on a ristocetin A-bonded chiral stationary phase used in the reversed-phase and in the polar organic chromatographic modes is reported. The effects of different parameters such as mobile phase composition, temperature, and the structure of the analytes on the selectivity in both chromatographic modes are discussed. By variation of the parameters, the separation of the stereoisomers was optimized and, as a result, baseline resolution was achieved in most cases.  相似文献   

8.
Cortisol 21-amine (21-amino-11β,17-dihydroxy-4-pregnene-3,20-dione) was prepared and an enzyme immunoassay for cortisol in serum was established using cortisol 21-amine conjugated with alkaline phosphatase. The minimal amount of cortisol detected was 1ng/tube and the measurable range was from 1 to 80 μg/d1, using 10 μ1 of serum sample. This enzyme immunoassay satisfied the standard criteria of dilution, accuracy and precision. The values correlated well with those obtained by radioimmunoassay. This enzyme Immunoassay is applicable to the routine determination of serum cortisol in any clinical laboratory. Cortisol 21-amine was found to be a useful derivative for preparing cortisol-enzyme conjugate in enzyme immunoassay.  相似文献   

9.
A homogeneously labeled insulin sample was prepared using 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) as the fluorescent-labeling reagent, and this was successfully applied to a chromatographic immunoassay. This labeled insulin was prepared by tagging all the three amino groups with AQC. Both CE and chromatographic immunoassay experiments indicated that the prepared insulin still kept its immunoaffinity to its antibody. It was observed that appropriate concentrations of acetonitrile (ACN) were efficient in lowering the quenching of the fluorescent signal of tagged insulin, in keeping the dilute, tagged insulin in solution, and in improving its peak shape during a chromatographic immunoassay. The tagged insulin was found to be 20-400 times more sensitive than native insulin detected under ultraviolet detection conditions. A competitive chromatographic immunoassay system was set up and calibrated. The system was used for analyses of an insulin-spiked urine sample, with a 96% recovery obtained.  相似文献   

10.
Two reversed-phase chromatographic methods for the separation of thiamine and related compounds are compared. The first procedure is based on the ion-pair technique using an octadecylsilica column, while the second uses a new amide-based stationary phase, which avoids the need to form ion-pairs, leading to narrower peaks and a simpler mobile phase. Analyses were performed by gradient elution and a photo-diode array was used for detection. Specificity was demonstrated by the retention characteristics, UV spectra and by comparing the peak purity index with commercial standards. The procedures were applied to the determination of thiamine-related compounds in pharmaceutical preparations and urine. No preliminary sample treatment was required.  相似文献   

11.
A column switching high performance liquid chromatographic method with estimable sensitivity and accuracy was developed for the determination of cetirizine and ambroxol in human plasma using nebivolol as the internal standard. Plasma samples were prepared by liquid-liquid extraction in methylene chloride and a mixture of diethylether (80:20, v/v). The extracted samples were injected into a multifunctional clean-up column Supelcosil LCABZ (50 mm × 4.6 mm, 5 μm particle size) using mobile phase 1 comprising acetonitrile-phosphate buffer (pH 3.5; 20 mM) (20:80, v/v). The eluate of cetirizine and ambroxol were separated to an analytical Kromasil C(8) micro bore column (50 mm × 0.3 mm, 5 μm particle size) via a column switching device. A Kromasil C(18) analytical column (250 mm × 2.1 mm, 5 μm particle size) was used as a separation column. Mobile phase 2 consisting acetonitrile-triethylamine (0.5%) in phosphate buffer (pH 3.5; 20mM) (55:45, v/v) was used for the compound elution. The eluents were detected at 230 nm with photodiode array detector. An aliquot of 150 μl of plasma sample was introduced into the pretreatment column via the auto sampler using mobile phase 1 at a flow rate of 0.5 ml/min, column switching valve being positioned at A. The pretreatment column retained cetirizine, ambroxol and nebivolol (IS) in the column leaving the residual proteins of plasma eluted in void volume and drained out. The switching valve was shifted to position B at 7.5 min. Cetirizine, ambroxol and IS were eluted from the pretreatment column between 7. 5 and 11.5 min and introduced to the concentration column. Finally, cetirizine, ambroxol and IS were introduced to the separation column by switching valve using mobile phase 2 at a flow rate of 0.4 ml/min. During the analysis the pretreatment column was washed for the next analysis and resume to the position A. The total run time was 25 min for a sample. The procedure was repeated for urine analysis also. The method was linear from 2 to 450 ng/ml and 7-300 ng/ml for cetirizine and ambroxol respectively in plasma and 1-500 ng/ml and 5-400 ng/ml, respectively for cetirizine and ambroxol in urine. Intra-day and inter-day precision of cetirizine and ambroxol was below 15% in terms of coefficient of variation and accuracy of cetirizine and ambroxol was ranged from 94 to 101.6% and 91.1 to 100.2%, respectively. The method demonstrated high sensitivity and selectivity and therefore, applied to evaluate pharmacokinetics of cetirizine and ambroxol in healthy human volunteer after a single oral administration. Urine samples obtained from healthy human volunteers and clinical subjects with renal impairment have also been analyzed by the method to compare the elimination pattern. The method was precise and accurate for the estimation of cetirizine and ambroxol both in blood and in urine.  相似文献   

12.
The effect of structural features of six pairs of enantiomers of cannabimimetic compounds on their chromatographic resolution on an amylose tris(3,5-dimethylphenylcarbamate) chiral stationary phase was studied using various compositions of n-hexane with 2-propanol and ethanol. Structural analysis by molecular mechanics was also performed to verify that the 3D conformation within this family of compounds was preserved with substitution. The homologous enantiomeric pairs showed better resolution when there was an additional OH group near the chiral centers (position 7 on the cannabinoid structure). Better resolution was observed also for the enantiomeric pair that had the smaller alkyl side chain. These differences indicated that the additional OH group contributed to a better discrimination of the enantiomers by the chiral sites of the stationary phase and that the bulkier alkyl side chain reduced it. The chromatographic resolution of two enantiomeric pairs of nonclassical cannabinoids HU-249 and HU-250, HU-255 and HU-256, was compared both in ethanol and 2-propanol. Both enantiomeric pairs showed relatively high resolution and selectivity, but the rigid benzofuran analogs (HU-249 and HU-250) exhibited better resolution using 2-propanol, in spite of the flexibility of the open chain analog (HU-255 and HU-256) and its additional OH group. The elution order of all the cannabinoids was (+)/(?) using both solvents. Unusual solvent effects were displayed by one enantiomeric pair, Δ6-THC, which was resolved easily using 2-propanol, but whose elution order reversed with 1% ethanol in the mobile phase. Partial separation was obtained at 5% ethanol [elution order (+)/(?)] and full separation was obtained at 0.5% ethanol [elution order (?)/(+)]. © 1995 Wiley-Liss, Inc.  相似文献   

13.
The optimal chromatographic conditions for the separation of the syn- and anti-geometric isomers of cefuroxime axetil applying RP-HPLC and micellar liquid chromatography (MLC) methods were investigated. The possibility to separate diastereoisomers of syn- and anti-cefuroxime axetil was observed. Investigations were performed using three columns, two classical silicas and one with hybrid particle technology. Three aqueous-organic and one micellar mobile phases were used. The best results were achieved using micellar mobile phase. Optimization study was performed using different micellar mobile phases. MLC method is sensitive and applicable in purity and stability testing.  相似文献   

14.
A method for the determination of a prostaglandin D(2) receptor antagonist (I, a compound being evaluated for the prevention of niacin induced flushing) and its acyl glucuronide metabolite (II) in human plasma is presented. The method utilized high performance liquid chromatography (HPLC) with tandem mass spectrometric (MS/MS) detection using an atmospheric pressure chemical ionization (APCI) interface operated in the positive ionization mode. The product ion was a radical cation generated via a homolytic bond cleavage. A chemical analog of the drug was used as internal standard (III). The acyl glucuronide metabolite (II) was detected using the same precursor-to-product ion transition used for the parent compound after chromatographic separation of I and II. Drug and metabolite were extracted using semi-automated, 96-well format solid phase extraction (SPE), and chromatography was performed using a reverse phase analytical column with an isocratic mobile phase. The chromatographic retention factor (k') of II was found to be highly sensitive to mobile phase formic acid concentration. An adjustment in mobile phase formic acid concentration improved the chromatographic separation between II and a mono-hydroxylated metabolite after an unexpected lack of MS/MS selectivity between the two molecules was observed. The dependence of retention factor on formic acid concentration (k' increased as formic acid concentration decreased) was thought to indicate polar interactions between II and the stationary phase. The stability of II in spiked human plasma was determined. The rate of hydrolysis back to parent compound was relatively low (approximately 0.1 and 0.5% per hour at room temperature and 4 degrees C, respectively) indicating that significant changes in analyte concentrations did not occur during sample processing. The concentration range of the assay was 10-2500 ng/mL for both drug and glucuronide metabolite.  相似文献   

15.
The analysis of hormones in saliva is a powerful tool in the assessment of a patient's endocrine function, since it allows multiple noninvasive samplings. Since salivary levels of most hormones are 10 to 50 times lower than plasma levels, accurate and highly sensitive assays are needed for saliva measurements. Herein, we describe the development of a solid-phase competitive immunoassay for cortisol in saliva, in which a mutant of the photoprotein aequorin has been used as a label. We have chemically conjugated cortisol to aequorin at different molar ratios. The various cortisol-aequorin conjugates were characterized in terms of bioluminescent activity and affinity for the anti-cortisol antibody. The conjugate that gave the best analytical performance was used for the development of the immunoassay and the analysis of cortisol in saliva samples. The conjugates were stable for at least 6 months when stored at 4 degrees C. The method fulfilled all the standard requirements of precision and accuracy. The optimized immunoassay gave a detection limit of 300 fmol/tube, corresponding to 3 nmol/L, with a linear dynamic range of 10-1000 nmol/L. Therefore, cortisol can be detected down to 0.1 ng in 100 microl of saliva sample using this assay, without any sample pretreatment. This detection limit is almost one order of magnitude lower than the physiological levels of salivary cortisol, which are reported to be 10-25 nmol/L. This allows the quantification of salivary cortisol to be performed in the linear range of the calibration curve, which is most reliable for quantification purposes.  相似文献   

16.
This paper describes a heterogeneous competitive flow immunoassay with a high sample throughput which can be used for the screening of smaller analytes in various samples. The method is based on off-line incubation of the analyte (Ag), a fluorescent labelled tracer (Ag*) and the corresponding antibody (Ab). The separation of bound (Ab-Ag*) and free tracer (Ag*) is based on a size exclusion and reversed phase mechanism utilizing a restricted access (RA) column. The column traps the free unbound tracer (Ag*) in its hydrophobic (C18) inner cavity but excludes the large Ab-Ag* complex, which is passed on and measured by the fluorescence detector. The flow immunoassay was developed using the triazine herbicide atrazine as a model compound owing to its human toxicity and widespread use. A sample throughput of 80 samples per hour and a detection limit of 300 pg ml-1 in water were obtained. Urine samples were successfully applied for direct injections into the flow system, while for human plasma samples an additional clean-up step using solid phase extraction was efficiently included where pure extract is obtained with the highly stable and biocompatible extracting column material. The resulting detection limits for atrazine in plasma and water samples using this clean-up and trace enrichment procedure were found to be 2 ng ml-1 and 20 pg ml-1 respectively.  相似文献   

17.
The goal of this work is to investigate the direct chromatographic separation of the enantiomers of fluoxetine and its active metabolite norfluoxetine. The liquid chromatographic retention behavior of these enantiomers on a β-cyclodextrin bonded-phase column was investigated with respect to mobile phase composition, pH, ionic strength, and solvent selectivity. Relationships were established between these factors and the three most important chromatographic parameters: retention time, resolution, and selectivity. Most of the evidence suggests that the unique selectivity of this column isdue to inclusion complex formation, which provides the physical basis for enantiomeric resolution. After these studies a set of optimum chromatographic conditions was chosen for the simultaneous separation/determination of a mixture of the four enantiomers using fluorescence detector. © 1993 Wiley-Liss, Inc.  相似文献   

18.
An improved method for the direct chromatographic resolution of abscisic acid enantiomers using the commercially available Whelk-O 1 chiral stationary phase is presented. Previously reported strategies utilized in the chromatographic separation of abscisic acid enantiomers are summarized, and conditions for analytical and semipreparative separations using the Whelk-O 1 chiral stationary phase are described. This method offers the advantages of rapid analysis time and greatly increased capacity, allowing the resolution of more than 6 mg in 25 min using an analytical column (4.6 mm i.d. × 25 cm length). © 1993 Wiley-Liss, Inc.  相似文献   

19.
Shan H  Pang J  Li S  Chiang TB  Wilson WK  Schroepfer GJ 《Steroids》2003,68(3):221-233
Oxygenated derivatives of cholesterol have important functions in many biochemical processes. These oxysterols are difficult to study because of their low physiological concentrations, the facile formation of cholesterol autoxidation artifacts, and lack of information on their chromatographic behavior. Focusing on metabolites and autoxidation products of cholesterol, we have documented the chromatographic mobilities of 35 oxysterols under a variety of conditions: eight solvent systems for thin-layer chromatography on silica gel, several mobile phases for reversed-phase high-performance liquid chromatography (HPLC), and two types of stationary phase for capillary gas chromatography (GC) using trimethylsilyl derivatives. Notable differences in selectivity could be obtained by modifying the stationary or mobile phases. Separations of oxysterol pairs isomeric at side-chain carbons or C-7 were achieved on normal-phase, reversed-phase, chiral, or silver-ion HPLC columns. Chromatographic behavior is also described for side-chain hexadeuterated and heptafluorinated oxysterols, which are useful as standards in isotope dilution analyses and autoxidation studies, respectively. The overall results are relevant to many problems of oxysterol analysis, including the initial separation of oxysterols from cholesterol, determination of highly polar and nonpolar oxysterols, separation of isomeric pairs, selection of derivatization conditions for GC analysis, and quantitation of the extent of cholesterol autoxidation.  相似文献   

20.
Tests of HPLC columns with restricted access, polymer covered alumina, polymer, and different ODS phases showed that base-acid compatible ODS columns gave the best peak shapes of cortisol, internal standard, as well as of plasma/serum (P/S) matrix components. Further trials with cortisol in P/S showed that three separation steps were essential in order to obtain chromatographic data which were superior to immunoassay data. Also, sufficient confidence in results required determination of each sample with two newly developed separation methods: (a) pre-separation with a restricted access column, concentration of the desired cut with a 20 mm base-acid compatible ODS column, and analysis with a 250 mm column filled with the same ODS; (b) pre-separation with an ultrafilter followed by the last two steps in (a). For detection UV was preferred over fluorescence. This twin multistep chromatography showed that immunoassays were very treacherous in that they produced a spectrum of results ranging from good to untenable without any warning whatever about functionality. The measurement of official controls, with reference values derived via gas chromatography-isotope dilution mass spectrometry, also demonstrated the superiority of the double HPLC method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号