首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A stereospecific method of analysis of racemic isosakuranetin (5,7-dihydroxy-4'-methoxyflavanone) in biological fluids is necessary to study pharmacokinetics. A simple high-performance liquid chromatographic method was developed for the determination of isosakuranetin enantiomers. Separation was achieved on a Chiralpak AD-RH column with ultraviolet (UV)-detection at 286 nm. The standard curves in urine were linear ranging from 0.5 to 100.0 microg/ml for each enantiomer. The mean extraction efficiency was >88.0%. Precision of the assay was <15% (CV) and was within 12% at the limit of quantitation (0.5 microg/ml). Bias of the assay was <15% and was within 6% at the limit of quantitation. The assay was applied successfully to stereospecific disposition of isosakuranetin enantiomers in rat urine.  相似文献   

2.
A valid, sensitive high-performance liquid chromatographic technique is reported for the separation of the two enantiomers of metoprolol in human plasma. The procedure involves pre-column derivatization with the homochiral reagent S-(+)-1-(1-naphthyl)-ethyl isocyanate. Once formed, the diastereomers are separated using normal-phase high-performance liquid chromatography. Fluorescence detection (220 nm excitation; no emission filter) was utilized, resulting in baseline resolution (Rs > 1.5). The peaks corresponding to metoprolol enantiomers were free from interference throughout the examined range of 5–500 ng/ml; accuracy and precision were within approximately 10%. Analysis of a plasma sample collected from a healthy volunteer demonstrated that the assay is applicable to clinical studies.  相似文献   

3.
4.
5.
Choline was isolated from deproteinized plasma by cation-exchange chromatography. Isolated choline was directly converted to the 3,5-dinitrobenzoate derivative and was analyzed by paired-ion high-performance liquid chromatography with UV detection at 254 nm. An internal standard, 3-hydroxy-N,N,N-trimethylpropanaminium iodide was used for quantitation of plasma choline.Linearity was achieved from 1–500 nmole/ml with a reproducibility of ± 6%. Plasma choline concentrations below 1 nmole/ml could not be accurately measured while plasma choline concentrations in the μmole/ml range deviated from linearity.  相似文献   

6.
A rapid and simple HPLC assay was developed for the determination of celecoxib in human plasma and breast milk. After proteins were precipitated with acetonitrile, celecoxib was resolved on a C18 column and detected by UV detection at 254 nm. Standard curves were linear over the concentration range 10-2000 microg/L (r(2)>0.99). Bias was 相似文献   

7.
A sensitive and simplified high-performance liquid chromatographic procedure has been developed for quantification of amiloride in rabbit plasma, as well as human plasma and urine. Following protein precipitation with perchloric acid, the supernatant was directly injected into a C18 Nucleosil column. The mobile phase consisted of methanol—water (45:55) containing 0.1 M perchloric acid, and the compound was quantitated using a fluorescence detector at excitation and emission wavelengths of 286 and 418 nm, respectively. The average recovery was 97.6%. The calibration curve was linear over the range 2.0–20.0 ng/ml. The limit of detection was 0.5 ng/ml.  相似文献   

8.
A rapid and simple HPLC assay was developed for the determination of rofecoxib in human plasma and breast milk. After solid-phase extraction, rofecoxib was resolved on a C18 column and detected by UV detection at 272 nm. Standard curves were linear over the concentration range 10-2000 microg/L (r2 >0.99). Intra- and inter-day coefficients of variation for both matrices were <10% and the limit of quantification was around 10 microg/L.  相似文献   

9.
We present new HPLC methods for the quantitation in human plasma of two investigative metallotexaphyrin agents, motexafin gadolinium (Gd-Tex) and motexafin lutetium (Lu-Tex). Each assay uses: the other texaphyrin analogue as an internal standard; protein precipitation with acetonitrile:methanol (50:50, v/v); an ODS reversed-phase column; an isocratic mobile phase of 100 mM ammonium acetate, pH 4.3:acetonitrile:methanol (59:21:20, v/v/v); and absorbance detection at 470 nm. The Gd-Tex assay has a lower limit of quantitation (LLOQ) of 0.01 μM and is linear between 0.01and 30 μM. The Lu-Tex assay has an LLOQ of 0.1 μM and is linear between 0.1 and 30 μM. The assays are suited for in vivo preclinical studies and clinical trials because they require minimal amounts of plasma, are sensitive, and involve a 30-min run time. These assays are important tools for evaluating the potential of Gd-Tex and Lu-Tex as a radiation enhancer and photosensitizer, respectively.  相似文献   

10.
A high-performance liquid chromatographic (HPLC) assay suitable for the analysis of the enantiomers of the non-steroidal anti-inflammatory drug ibuprofen (IB) in plasma was developed. Following the addition of racemic fenoprofen as internal standard (I.S.), samples are acidified and extracted with a mixture of isooctane—isopropanol (95:5, v/v). After evaporation of the organic layer, the drug and I.S. are derivatized with S-(−)-1(1-naphthyl)ethylamine (S-NEA) after addition of ethyl chloroformate as the coupling reagent. Ethanolamine is added 3 min after the addition of S-NEA to react with the excessive ethyl chloroformate. The resultant diastereomers corresponding to IB and I.S. were chromatographed at ambient temperature on a 100 mm × 4.6 mm I.D. C18 reversed-phase column using acetonitrile—water—acetic acid—triethylamine (60:40:0.1:0.02) as the mobile phase pumped at a flow-rate of 1.2 ml/min. Detection of the fluorescent chromophore was at 280 and 320 nm for excitation and emission, respectively. The suitability of the assay for clinical pharmacokinetic studies of IB was determined by the analysis of plasma samples obtained from a healthy volunteer, following administration of a single 400-mg oral dose of racemic IB.  相似文献   

11.
12.
Endralazine (I) is a new antihypertensive which is chemically and pharmacologically related to hydralazine and dihydralazine. A sensitive high-performance liquid chromatographic-fluorescence assay for the drug and two of its metabolites [methyltriazoloendralazine (VII) and hydroxymethyltriazoloendralazine (VIII)] in human plasma was developed. After conversion of I and its internal standard to triazolopyridopyridazine derivatives the latter and metabolites were separated by high-performance liquid chromatography and detected using their fluorescence. The limits of detection of the assay were 1 nmol/l for I and VII and 0.1 nmol/l for VIII. Intra-assay coefficients of variation were 2.5–5.1% for I (range 1000–10 nmol/l), 4.2–4.5% for VII (range 100–5 nmol/l) and 3.4–5.7% for VIII (range 100–1 nmol/l). Following oral administration of 5 and 10 mg of I to two normal volunteers (slow acetylators) peak plasma levels of I occurred between 0.75 and 1 h after the dose, and declined in a biexponential fashion. The terminal half-life ranged from 2.8–3.7 h. These results contrast with those obtained for hydralazine in plasma where in vitro and in vivo half-lives were 30 min.  相似文献   

13.
A sensitive, specific and stability-indicating high-performance liquid chromatographic (HPLC) assay, involving pre-column derivatization and solid-phase extraction (SPE), was developed and validated for the quantitation of busulfan (BU) in aqueous and plasma samples. The linearity of the assay was in the concentration ranges of 0.15–10 μg/ml and 0.15–3 μg/ml for aqueous and plasma samples, respectively. The within-day and between-day variations were 2.90 and 3.31%, respectively, for the aqueous samples, and 9.24 and 14.56%, respectively, for the plasma samples. The overall recovery, derivatization yield and SPE efficiency of BU from plasma samples were 82.03, 108.01 and 86.69%, respectively. Forced degraded samples, either in highly acidic, neutral or basic medium, produced no interfering peaks in the chromatogram. The reported assay requires only 0.2 ml of plasma for the analysis, and its sensitivity is 150 ng/ml by monitoring samples at a wavelength of 254 nm, sufficient to study the plasma pharmacokinetics of BU in rats after a clinically relevant oral dose. Moreover, the sensitivity of the assay can be significantly increased to 30 ng/ml by monitoring samples at a wavelength of 278 nm. The applications of the assay were demonstrated with BU solubility measurements in two aqueous systems and with plasma samples from a Sprague–Dawley rat for an in vivo pharmacokinetic study. In addition, the assay has been employed in the development of a patented intravenous formulation, and in evaluations of stability, preclinical pharmacokinetics in rats and dogs, and clinical phase I trial of the formulation. The assay is readily adaptable to clinical therapeutic drug monitoring.  相似文献   

14.
Olanzapine is a commonly used atypical antipsychotic medication for which therapeutic drug monitoring has been proposed as clinically useful. A sensitive method was developed for the determination of olanzapine concentrations in plasma and urine by high-performance liquid chromatography with low-wavelength ultraviolet absorption detection (214 nm). A single-step liquid–liquid extraction procedure using heptane-iso-amyl alcohol (97.5:2.5 v/v) was employed to recover olanzapine and the internal standard (a 2-ethylated olanzapine derivative) from the biological matrices which were adjusted to pH 10 with 1 M carbonate buffer. Detector response was linear from 1–5000 ng (r2>0.98). The limit of detection of the assay (signal:noise=3:1) and the lower limit of quantitation were 0.75 ng and 1 ng/ml of olanzapine, respectively. Interday variation for olanzapine 50 ng/ml in plasma and urine was 5.2% and 7.1% (n=5), respectively, and 9.5 and 12.3% at 1 ng/ml (n=5). Intraday variation for olanzapine 50 ng/ml in plasma and urine was 8.1% and 9.6% (n=15), respectively, and 14.2 and 17.1% at 1 ng/ml (n=15). The recoveries of olanzapine (50 ng/ml) and the internal standard were 83±6 and 92±6% in plasma, respectively, and 79±7 and 89±7% in urine, respectively. Accuracy was 96% and 93% at 50 and 1 ng/ml, respectively. The applicability of the assay was demonstrated by determining plasma concentrations of olanzapine in a healthy male volunteer for 48 h following a single oral dose of 5 mg olanzapine. This method is suitable for studying olanzapine disposition in single or multiple-dose pharmacokinetic studies.  相似文献   

15.
Local transcutaneous delivery of non-steroidal anti-inflammatory drugs avoids gastrointestinal side effects and concentrates drugs in the intended tissues. An extraction and HPLC method was developed for ketoprofen in skin, fascia and muscle. Tissue samples were homogenized in NaHCO3. After methylene chloride removal of lipids, the aqueous layer was acidified with HCl and back extracted into isooctane/isopropanol. Ketoprofen was derivatized with ethylchloroformate/S-(−)-α-phenylethylamine in triethylamine, then detected by HPLC. Ketoprofen recovery was linear (1–33 μg/g) and was detected in these tissues following in vivo cathodic iontophoresis (160 mA*min). This represents the first non-radioactive method for determination of ketoprofen in tissues following transcutaneous iontophoresis.  相似文献   

16.
Moguisteine is a novel peripheral non-narcotic antitussive agent. Pharmacokinetic studies in animal and in man showed that no unchanged drug is present in plasma, urine and faeces after oral administration. The main active metabolite, M1, is the free carboxylic acid of moguisteine, which maintains a stereogenic centre and consists of R(+)-M1 and S(−)-M1 enantiomers. M1 is partly metabolized to M2, its sulfoxidation derivative. A conventional HPLC method is described for the simultaneous determination of M1 and M2 in human plasma and urine after administration of therapeutic moguisteine doses. Plasma samples, previously acidified with phosphoric acid, are extracted with dichloromethane; urine samples are analyzed after appropriate dilution with methanol. Chromatography is performed using a Lichrosorb RP2 column and a linear gradient. M1 enantiomers can be determined in plasma extracts and urine samples by a chiral HPLC method using a β-cyclodextrin column. The analytical characteristics of both HPLC procedures proved to be adequate to analyze samples of subjects treated with therapeutic doses of moguisteine during clinical pharmacokinetic studies.  相似文献   

17.
A reversed-phase liquid chromatographic method with ultraviolet detection has been developed to determine busulfan concentrations in plasma of children undergoing bone marrow transplantation. Plasma samples (200 μl) containing busulfan and 1,6-bis(methanesulfonyloxy)hexane as an internal standard were prepared by a simple derivatization method with diethyldithiocarbamate followed by extraction with ethyl acetate and solid-phase purification on C8 columns conditioned with methanol and water and eluted with acetonitrile (recovery 99%). Chromatography was accomplished using a Hypersil octadecylsilyl column (10 cm×4.6 mm I.D.) and a mobile phase of acetonitrile, tetrahydrofuran and distilled water (65:5:30, v/v). The limit of detection was 25 ng/ml (signal-to-noise ratio of 5). Calibration curves were linear up to 25 000 ng/ml. Intra-day and inter-day coefficients of variation of the assay were ≤5%. This method was used to analyse busulfan plasma concentrations after oral administration within the framework of therapeutic drug monitoring and pharmacokinetic studies in children.  相似文献   

18.
A simple, rapid and sensitive high-performance liquid chromatographic method was developed for determination of ibuprofen, (+/-)-(R, S)-2-(4-isobutylphenyl)-propionic acid, enantiomers in rat serum. Serum (0.1 ml) was extracted with 2,2,4-trimethylpentane/isopropanol (95:5, v/v) after addition of the internal standard, (S)-naproxen, and acidification with H(2)SO(4). Enantiomeric resolution of ibuprofen was achieved on ChiralPak AD-RH column with ultraviolet (UV) detection at 220 nm without interference from endogenous co-extracted solutes. The calibration curve demonstrated excellent linearity between 0.1 and 50 microg/ml for each enantiomer. The mean extraction efficiency was >92%. Precision of the assay was within 11% (relative standard deviation (R.S.D.)) and bias of the assay was lower than 15% at the limit of quantitation (0.1 microg/ml). The assay was applied successfully to an oral pharmacokinetic study of ibuprofen in rats.  相似文献   

19.
20.
A simple, sensitive and reproducible high-performance liquid chromatography (HPLC) method was developed for the determination of terazosin in human plasma. The method involves a one-step single solvent extraction procedure using dichloromethane with a 0.25 ml plasma sample. Recovery values were all greater than 90% over the concentration range 0.25–100 ng/ml. Terazosin was found to adsorb to glass or plastic tubes, but this could be circumvented by using disposable plastic tubes. Also, rinsing the injector port with methanol after each injection helped to prevent any carry-over effect. The internal standard, prazosin, did not exhibit this problem. The method has a quantification limit of 0.25 ng/ml. The within- and between-day coefficient of variation and accuracy values were all less than 7% over the concentration range 0.25–100 ng/ml and hence the method is suitable for use in pharmacokinetic studies of terazosin.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号