首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
In this study, high-resolution computed tomography X-ray scanning was used to scan ring-tailed lemur (Lemur catta) copulatory plugs. This method produced accurate measures of plug volume and surface area, but was not useful for visualizing plug internal structure. Copulatory plug size was of interest because it may relate to male fertilization success. Copulatory plugs form from coagulated ejaculate, and are routinely displaced in this species by the penis of a subsequent mate during copulation (Parga [2003] Int. J. Primatol. 24:889-899). Because one potential function of these plugs may be to preclude or delay other males' successful insemination of females, we tested the hypothesis that larger plugs are more difficult for subsequent males to displace. Plugs were collected opportunistically upon displacement during data collection on L. catta mating behavior on St. Catherines Island, Georgia (USA) during two subsequent breeding seasons. Copulatory plugs exhibited a wide range of volumes: 1,758-5,013.6 mm3 (n = 9). Intraindividual differences in plug volume were sometimes greater than interindividual differences. Contrary to predictions, larger plugs were not more time-consuming for males to displace via penile intromission during copulation. Nor were plugs with longer vaginal residence times notably smaller than plugs with shorter residence times, as might be expected if plugs disintegrate while releasing sperm (Asdell [1946] Patterns of Mammalian Reproduction; Ithaca: Comstock). We found a significant inverse correlation between number of copulatory mounts leading to ejaculation and copulatory plug volume. This may indicate that if males are sufficiently sexually aroused to reach ejaculation in fewer mounts, they tend to produce ejaculates of greater volume.  相似文献   

2.
Special methods have been developed to use computed tomography (CT) for 3-dimensional imaging of both fossil and extant bones. Most commercial CT scanners cannot display the internal structure of fossils because the very high density is beyond the upper limits of the normal CT number scale (Hounsfield scale) of the scanners. X-ray projections from CT scans of fossils were modified by scaling the data to provide an expanded CT number scale, allowing the internal structure of highly fossilized objects to be visualized. These images were compared with state-of-the-art, high-resolution CT images of extant bone. Special image reformatting software was used to provide qualitative and quantitative 3-dimensional imaging. The recent rapid advances in CT technology have made this imaging modality the procedure of choice in much of diagnostic radiology. Use of this tool in paleoanthropology has been limited in the past by restricted access to scanners. However, new developments in CT will make this technique available to many researchers in the near future.  相似文献   

3.
4.
5.
6.
In nine anesthetized dogs, accuracy of noninvasive measurements of lung weight (W) and gas volume in vivo was determined from volume and density determined by computed tomography (CT) and by rebreathing helium and the soluble gases dimethyl ether (WDME) and acetylene (WC2H2). Reference standards were obtained from the postmortem scale weight of the frozen lungs (Wscale) and compared with the CT lung weights measured in the living dog (WCT-38) and the frozen carcass (WCT-cold). WCT-cold did not significantly differ from Wscale [-2 +/- 9% (SD), P = 0.7]. WCT-cold was 10% greater than WCT-38 (0.10 greater than P greater than 0.05), suggesting an increase in lung weight despite immediately commencing freezing after death. WDME measured 64 +/- 6% and WC2H2 56 +/- 12% of WCT-38. Serial multiple measurements in three dogs over 14 wk showed a coefficient of variation (CV) of 10 +/- 2% for WDME, 18 +/- 2% for WC2H2, 4.1 +/- 0.9% for WCT, 2.6 +/- 0.8% for CT density, and 3.5 +/- 1.6% for functional residual capacity (FRC) by CT. FRC calculated from CT consistently underestimated FRC measured by rebreathing helium by 18 +/- 8% (P less than 0.005). This error, despite good agreement between WCT and Wscale, was explained by underestimation of CT total lung volume and overestimation of lung density by factors known to affect CT readings, such as partial volume effects, beam hardening, and limited number of input signals. These data show that CT scanning can provide serial measurement of the mass, density, and volume of the lungs with a CV in the order of 5%, but the rebreathing of soluble gases gives more than double this variability. Measurements of WDME performed on the same day had a CV of 3 +/- 1%, so that WDME provides a precise noninvasive means to measure lung weight in acute studies.  相似文献   

7.
The development of hybrid optical tomography methods to improve imaging performance has been suggested over a decade ago and has been experimentally demonstrated in animals and humans. Here we examined in vivo performance of a camera-based hybrid fluorescence molecular tomography (FMT) system for 360° imaging combined with X-ray computed tomography (XCT). Offering an accurately co-registered, information-rich hybrid data set, FMT-XCT has new imaging possibilities compared to stand-alone FMT and XCT. We applied FMT-XCT to a subcutaneous 4T1 tumor mouse model, an Aga2 osteogenesis imperfecta model and a Kras lung cancer mouse model, using XCT information during FMT inversion. We validated in vivo imaging results against post-mortem planar fluorescence images of cryoslices and histology data. Besides offering concurrent anatomical and functional information, FMT-XCT resulted in the most accurate FMT performance to date. These findings indicate that addition of FMT optics into the XCT gantry may be a potent upgrade for small-animal XCT systems.  相似文献   

8.

Background

Arterial tortuosity syndrome (ATS) (OMIM #208050) is a rare autosomal recessive connective tissue disorder characterized by tortuosity and elongation of the large and medium-sized arteries, propensity to aneurysms formation, vascular dissection, and pulmonary arteries stenosis. ATS is caused by mutations in SLC2A10 gene, encoding for the facilitative glucose transporter 10 (GLUT10). So far, 17 SLC2A10 mutations have been reported in 32 families, two of which were Italian with a total of five patients. Here we present the clinical and molecular characterization of two novel Italian paediatric ATS patients.

Methods

The exons and intronic flanking regions of SLC2A10 gene were amplified and direct sequencing was performed.

Results

In both patients, the involvement of major- and medium-sized arteries was characteristic; the nonvascular connective tissue manifestations were mild and not pathognomic of the disorder. Both patients, born from non-consanguineous parents, were heterozygous for two different SLC2A10 mutations, three of which were recurrent and one was novel (p.Arg231Trp). This mutation is localized at the endofacial loop between the transmembrane domains 6 and 7 of GLUT10.

Conclusion

Two novel ATS patients were characterized at clinical and molecular level. Overall, four ATS unrelated families are known in Italy so far. Though ATS clinical delineation improved in the last years, further works in the comprehension of disease presentation and complications onset, particularly in paediatric age, and on ATS molecular basis are needed to add new insights for diagnosis and prevention strategies for related complications.  相似文献   

9.
A recent study has reported that the application of thermal energy delivered through a bronchoscope (bronchial thermoplasty) impairs the ability of airway smooth muscle to shorten in response to methacholine (MCh)(Danek CJ, Lombard CM, Dungworth DL, Cox PG, Miller JD, Biggs MJ, Keast TM, Loomas BE, Wizeman WJ, Hogg JC, and Leff AR. J Appl Physiol 97: 1946-1953, 2004). If such a technique is successful, it has the potential to serve as a therapy to attenuate airway narrowing in asthmatic subjects regardless of the initiating cause that stimulates the smooth muscle. In the present study, we have applied high-resolution computed tomography to accurately quantify the changes in airway area before and after a standard MCh aerosol challenge in airways treated with bronchial thermoplasty. We studied a total of 193 airways ranging from 2 to 15 mm in six dogs. These were divided into treated and control populations. The MCh dose-response curves in untreated airways and soon-to-be-treated airways were superimposable. In contrast, the dose-response curves in treated airways were shifted upward at all points, showing a significantly decreased sensitivity to MCh at both 2 and 4 wk posttreatment. These results thus show that treated airways have significantly increased luminal area at any dose of inhaled MCh compared with untreated airways. The work in this study thus supports the underlying concept that impairing the smooth muscle may be an effective treatment for asthma.  相似文献   

10.
The issue of inadequate solid standards for correcting nonuniformity in single photon emission computed tomography was addressed. Controlled, complex, motion of commercially available cobalt-57 standards was found to enhance the perceived nonuniformity of the standard and to minimize the effects of any local flaws. This maneuver provides a better standard than a refillable liquid phantom without the problems inherent in radioactive liquid standards which include: phantom deformation, poor mixing, absence of retrospective verification, accidental contamination and substantial handling requirements.  相似文献   

11.
Micro computed tomography (µCT) scanners are used to create high-resolution images and to quantify properties of the scanned objects. While modern µCT scanners benefit from the cone beam geometry, they are compromised by scatter radiation. This work aims to develop a Monte Carlo (MC) model of a µCT scanner in order to characterize the scatter radiation in the detector plane.The EGS++ framework with the MC code EGSnrc was used to simulate the particle transport through the main components of the XtremeCT (SCANCO Medical AG, Switzerland). The developed MC model was based on specific information of the manufacturer and was validated against measurements. The primary and the scatter radiation were analyzed and by implementing a dedicated tracing method, the scatter radiation was subdivided into different scatter components.The comparisons of measured and simulated transmission values for different absorber and filter combinations result in a mean difference of 0.2% ± 1.4%, with a maximal local difference of 3.4%. The reconstructed image of the phantom based on measurements agrees well with the image reconstructed using the MC model. The local contribution of scattered radiation is up to 10% of the total radiation in the detector plane and most of the scattered particles result from interactions in the scanned object. The MC simulations show that scatter radiation contains information about the structure of the object.In conclusion, a MC model for a µCT scanner was successfully validated and applied to analyze the characteristics of the scatter radiation for a µCT scanner.  相似文献   

12.

Recent studies suggest a causal link of childhood leukemia and brain tumor with repeated computed tomography (CT) scans. The reasons why frequent CT scans are taken in a specific child remain unclear. The present study aimed to clarify the medical reasons why frequent CT examinations in children, and the characteristics of the diseases of those children that required multiple CT scans. A long-term follow-up retrospective study was conducted over a 12.75-year period at a single institution. Radiological reports were investigated that contained the indications for the CT scans. The clinical indications were classified for the examination of children under 16 years of age who underwent more than three CT scans into trauma, tumor, inflammation, and others. This study showed that 8.5% of CT examinations were done three times or more. The numbers of patients by indication were 23.3% for trauma, 5.3% for hydrocephalus, and 2.3% for appendicitis. The frequencies of trauma and inflammation decreased rapidly with an increasing number of CT scans. In particular, hydrocephalus brought high frequency more than ten scans. Regarding the frequencies of clinical indications by age groups, there was a significant difference (p<0.05). The near-13-year follow-up study indicated the main clinical indications for frequent CT scans in children were trauma and hydrocephalus. Multiple follow-up CT scans in children with hydrocephalus would be traded off against the resultant increase in brain tumor risk associated with CT exposure.

  相似文献   

13.
The paper summarizes the results of examination of 100 patients with malignant tumors of the lung. The results of X-ray study, linear tomography, and computed tomography (CT) used in the examination of patients with lung cancer were compared by using as an indicator the following parameters: to make diagnosis of lung cancer, to reveal mediastinal intergrowths, to detect enlarged lymph nodes, pulmonary metastases, and pleural lesions, to obtain information on tumor spread into the chest, to reveal growths into the vascular walls. To evaluate the efficiency of the techniques in solving the above diagnostic tasks, a statistical analysis including the estimation of their accuracy, specificity, and sensitivity was made. Recommendations for examination of patients with lung cancer were drawn up for therapeutic institutions of different types.  相似文献   

14.
In the period 2009 to 2010, diagnostic multislice spiral computed tomography (MSCT) was carried out in 49 patients with gastric cancer. The efficiency of dynamic MSCT in detecting a tumor and determining its locoregional extent was evaluated. The results of dynamic MSCT were compared with those of postoperative histological examination. The possibility of detecting gastric cancer by dynamic MSCT was ascertained to depend on the depth of tumor invasion and to average 29, 71, 72, and 77% for T1, T2, T3, and T4, respectively. Dynamic MSCT showed a correlation between the frequency of metastatic lesion and the sizes of lymph nodes (r = 0.54; p = 0.0001) and their number (r = 0.82; p < 0.0001).  相似文献   

15.
ObjectiveStudying the diagnostic value of CT imaging in non-small cell lung cancer (NSCLC), and establishing a prognosis model combined with clinical characteristics is the objective, so as to provide a reference for the survival prediction of NSCLC patients.MethodCT scan data of NSCLC 200 patients were taken as the research object. Through image segmentation, the radiology features of CT images were extracted. The reliability and performance of the prognosis model based on the optimal feature number of specific algorithm and the prognosis model based on the global optimal feature number were compared.Results30-RELF-NB (30 optimal features, RELF feature selection algorithm and NB classifier) has the highest accuracy and AUC (area under the subject characteristic curve) in the prognosis model based on the optimal features of specific algorithm. Among the prognosis models based on global optimal features, 25-NB (25 global optimal features, naive Bayes classification algorithm classifier) has the highest accuracy and AUC. Compared with the prediction model based on feature training of specific feature selection algorithm, the overall performance and stability of the prediction model based on global optimal feature are higher.ConclusionThe prognosis model based on the global optimal feature established in this paper has good reliability and performance, and can be applied to the CT radiology of NSCLC.  相似文献   

16.
17.
Cyclooxygenase-2 (COX-2) inhibitors are rapidly emerging as a new generation of therapeutic drug in combination with chemotherapy or radiation therapy for the treatment of cancer. The mechanisms underlying its antitumor effects are not fully understood and more thorough preclinical trials are needed to determine if COX-2 inhibition represents a useful approach for prevention and/or treatment of breast cancer. The purpose of this study was to evaluate the growth inhibitory mechanism of a highly selective COX-2 inhibitor, celecoxib, in an in vivo oncogenic mouse model of spontaneous breast cancer that resembles human disease. The oncogenic mice carry the polyoma middle T antigen driven by the mouse mammary tumor virus promoter and develop primary adenocarcinomas of the breast. Results show that oral administration of celecoxib caused significant reduction in mammary tumor burden associated with increased tumor cell apoptosis and decreased proliferation in vivo. In vivo apoptosis correlated with significant decrease in activation of protein kinase B/Akt, a cell survival signaling kinase, with increased expression of the proapoptotic protein Bax and decreased expression of the antiapoptotic protein Bcl-2. In addition, celecoxib treatment reduced levels of proangiogenic factor (vascular endothelial growth factor), suggesting a role of celecoxib in suppression of angiogenesis in this model. Results from these preclinical studies will form the basis for assessing the feasibility of celecoxib therapy alone or in combination with conventional therapies for treatment and/or prevention of breast cancer.  相似文献   

18.
PurposeIn cone-beam computed tomography dedicated to the breast (BCT), the mean glandular dose (MGD) is the dose metric of reference, evaluated from the measured air kerma by means of normalized glandular dose coefficients (DgNCT). This work aimed at computing, for a simple breast model, a set of DgNCT values for monoenergetic and polyenergetic X-ray beams, and at validating the results vs. those for patient specific digital phantoms from BCT scans.MethodsWe developed a Monte Carlo code for calculation of monoenergetic DgNCT coefficients (energy range 4.25–82.25 keV). The pendant breast was modelled as a cylinder of a homogeneous mixture of adipose and glandular tissue with glandular fractions by mass of 0.1%, 14.3%, 25%, 50% or 100%, enveloped by a 1.45 mm-thick skin layer. The breast diameter ranged between 8 cm and 18 cm. Then, polyenergetic DgNCT coefficients were analytically derived for 49-kVp W-anode spectra (half value layer 1.25–1.50 mm Al), as in a commercial BCT scanner. We compared the homogeneous models to 20 digital phantoms produced from classified 3D breast images.ResultsPolyenergetic DgNCT resulted 13% lower than most recent published data. The comparison vs. patient specific breast phantoms showed that the homogeneous cylindrical model leads to a DgNCT percentage difference between −15% and +27%, with an average overestimation of 8%.ConclusionsA dataset of monoenergetic and polyenergetic DgNCT coefficients for BCT was provided. Patient specific breast models showed a different volume distribution of glandular dose and determined a DgNCT 8% lower, on average, than homogeneous breast model.  相似文献   

19.
PurposeWithin the SYRMA-CT collaboration based at the ELETTRA synchrotron radiation (SR) facility the authors investigated the imaging performance of the phase-contrast computed tomography (CT) system dedicated to monochromatic in vivo 3D imaging of the female breast, for breast cancer diagnosis.MethodsTest objects were imaged at 38 keV using monochromatic SR and a high-resolution CdTe photon-counting detector. Signal and noise performance were evaluated using modulation transfer function (MTF) and noise power spectrum. The analysis was performed on the images obtained with the application of a phase retrieval algorithm as well as on those obtained without phase retrieval. The contrast to noise ratio (CNR) and the capability of detecting test microcalcification clusters and soft masses were investigated.ResultsFor a voxel size of (60 μm)3, images without phase retrieval showed higher spatial resolution (6.7 mm−1 at 10% MTF) than corresponding images with phase retrieval (2.5 mm−1). Phase retrieval produced a reduction of the noise level and an increase of the CNR by more than one order of magnitude, compared to raw phase-contrast images. Microcalcifications with a diameter down to 130 μm could be detected in both types of images.ConclusionsThe investigation on test objects indicates that breast CT with a monochromatic SR source is technically feasible in terms of spatial resolution, image noise and contrast, for in vivo 3D imaging with a dose comparable to that of two-view mammography. Images obtained with the phase retrieval algorithm showed the best performance in the trade-off between spatial resolution and image noise.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号