首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 312 毫秒
1.
Herein, we describe a new chiral amorphous metal–organic polyhedra used as the stationary phase for high-resolution gas chromatography (GC). The chiral stationary phase was coated onto a capillary column via a dynamic coating process and investigated for a variety of compounds. The experimental results showed that the chiral stationary phase exhibits good selectivity for linear alkanes, linear alcohols, polycyclic aromatic hydrocarbons, isomers, and chiral compounds. In addition, the column has the advantages of high column efficiency and short analysis time. The present work indicated that amorphous metal–organic polyhedra have great potential for application as a new type of stationary phase for GC.  相似文献   

2.
A chiral capillary monolithic column for capillary electrochromatography (CEC) was prepared by covalent bonding of cellulose tris(3,5-dimethylphenylcarbamate) (CDMPC) on the silica monolithic matrix within the confine of a 50-microm i.d. bare fused silica capillary. Several pairs of enantiomers including neutral and basic analytes were baseline resolved on the newly prepared chiral capillary monolithic column in CEC with aqueous mobile phases. Fast enantioseparation was achieved due to the favorable dynamic properties of silica monolith. The covalent bonding of CDMPC as the chiral stationary phase for CEC also enabled the use of THF in mobile phase for enantioseparation of prazquantel by overcoming the incompatibility of THF and the physically coated CDMPC on a column.  相似文献   

3.
Up to now, some chiral metal‐organic frameworks (MOFs) have been reported for enantioseparation in liquid chromatography. Here we report a homochiral MOF, [Cd2(d‐cam)3]·2Hdma·4dma, used as a new chiral stationary phase for high‐performance liquid chromatographic enantioseparation. Nine racemates of alcohol, naphthol, ketone, and base compounds were used as analytes for evaluating the separation properties of the chiral MOF packed column. Moreover, some effects such as mobile phase composition, column temperature, and analytes mass for separations on this chiral column also were investigated. The relative standard deviations for the resolution values of run‐to‐run and column‐to‐column were less than 2.1% and 3.2%, respectively. The experimental results indicate that the homochiral MOF offered good recognition ability, which promotes the application of chiral MOFs use as stationary phase for enantioseparation. Chirality 28:340–346, 2016. © 2016 Wiley Periodicals, Inc.  相似文献   

4.
The chiral selector vancomycin was used either as mobile phase additive or bound as a chiral stationary phase (CSP) for the stereoselective separation of seven racemic nonsteroidal anti-inflammatory drugs (NSAIDs), fenoprofen, carprofen, flurbiprofen, indoprofen, flobufen, ketoprofen, and suprofen, by capillary liquid chromatography. The effect of the type of stationary phase, the chiral column Chirobiotic V or the achiral stationary phases Nucleosil 100 C8 HD and Nucleosil 100 C18 HD, and the concentration of vancomycin in the mobile phase on separation of the drug enantiomers were evaluated. All the drugs, except flobufen, were successfully enantioseparated on Nucleosil 100 C8 HD with 4 mM vancomycin present in the mobile phase (composed of methanol and buffer) in the reversed phase mode. On the vancomycin-bonded chiral stationary phase, it was difficult to get enantioseparations of the profen NSAIDs. However, flobufen gave better enantioseparation on the vancomycin CSP. The better enantioresolution of the majority of profen derivatives on the achiral columns with vancomycin added to the mobile phase can be attributed in particular to the higher separation efficiency of this capillary chromatographic system. In addition, vancomycin dimers, formed in the mobile phase, seem to offer a better steric arrangement for stereoselective interaction to these analytes than the vancomycin bonded on the CSP. These substantial differences in the CS structure significantly influence the chiral discrimination mechanism.  相似文献   

5.
The technique of automated in-tube solid-phase microextraction (SPME) coupled with liquid chromatography–electrospray ionization mass spectrometry (LC–ESI-MS) was evaluated for the determination of ranitidine. In-tube SPME is an extraction technique for organic compounds in aqueous samples, in which analytes are extracted from the sample directly into an open tubular capillary column by repeated aspirate/dispense steps. In order to optimize the extraction of ranitidine, several in-tube SPME parameters such as capillary column stationary phase, extraction pH and number and volume of aspirate/dispense steps were investigated. The optimum extraction conditions for ranitidine from aqueous samples were 10 aspirate/dispense steps of 30 μl of sample in 25 mM Tris–HCl (pH 8.5) with an Omegawax 250 capillary column (60 cm×0.25 mm I.D., 0.25 μm film thickness). The ranitidine extracted on the capillary column was easily desorbed with methanol, and then transported to the Supelcosil LC-CN column with the mobile phase methanol–2-propanol–5 M ammonium acetate (50:50:1). The ranitidine eluted from the column was determined by ESI-MS in selected ion monitoring mode. In-tube SPME followed by LC–ESI-MS was performed automatically using the HP 1100 autosampler. Each analysis required 16 min, and carryover of ranitidine in this system was below 1%. The calibration curve of ranitidine in the range of 5–1000 ng/ml was linear with a correlation coefficient of 0.9997 (n=24), and a detection limit at a signal-to-noise ratio of three was ca. 1.4 ng/ml. The within-day and between-day variations in ranitidine analysis were 2.5 and 6.2% (n=5), respectively. This method was also applied for the analyses of tablet and urine samples.  相似文献   

6.
The separation of polar compounds by supercritical-fluid chromatography (SFC) is reviewed. New developments in mobile and stationary phase tuning are reviewed for packed and packed capillary SFC. In terms of mobile phase polarity adjustment, new pure and multiple component fluids are presented. The approach of tuning the polarity of the stationary phase as a way of increasing the range of polar compounds analyzed by SFC using pure CO(2) is discussed using either silica-based or new materials as stationary phase. Chiral, liquid crystal and polymer-based stationary phases coated on particles are widely covered in this review as an interesting approach to separate polar compounds avoiding the major drawbacks associated to the use of modifiers in SFC.  相似文献   

7.
Chiral resolutions of trifluoroacetyl‐derivatized 1‐phenylalkylamines with different type and position of substituent were investigated by capillary gas chromatography by using heptakis(2,3‐di‐O‐methyl‐6‐Otert‐butyldimethylsilyl)‐β‐cyclodextrin diluted in OV‐1701 as a chiral stationary phase. The influence of column temperature on retention and enantioselectivity was examined. All enantiomers of meta‐substituted analytes as well as fluoro‐substituted analytes could be resolved. Temperature had a favorable influence on enantioselectivity for small amines with substituents at the ortho‐position. The type of substituent at the stereogenic center of amines also had a crucial effect as the ethyl group led to poor enantioseparation. Among all analytes studied, trifluoroacetyl‐derivatized 1‐(2′‐fluorophenyl)ethylamine exhibited baseline resolution with the shortest analysis time.  相似文献   

8.
A novel sample preparation protocol for gas chromatographic (GC) analysis of amino acid enantiomers in peptides was developed. It comprises traditional acid hydrolysis, a novel treatment of the analytes with a fluoroalkyl chloroformate and GC/FID separation of enantiomers on a chiral capillary column. The major improvements consist in that the derivatization step proceeds in organic-aqueous media within seconds and the amino acid derivatives are volatile enough to suit the temperature range of the chiral Chirasil-Val capillary column. The approach was found beneficial for chiral analysis of pharmaceutically important Carbetocin peptide.  相似文献   

9.
Chiral separation by normal phase high performance liquid chromatography is one of the most powerful technique to quantify the chiral purity of the compounds. In this study, a novel, simple, and specific analytical method was proposed to ascertain the chiral purity of alvimopan (ALV). The normal phase HPLC method was developed based on cellulose tris (3,5‐dichlorophenylcarbamate) stationary phase. The separation of ALV isomers achieved by using column CHIRALPAK IC (250 × 4.6 mm, 5 μm), mobile phase n‐hexane: isopropyl alcohol: ethanol: diethylamine (650:200:150:5 v/v), column oven temperature 30°C, flow rate 1.0 mL min?1, injection volume was 10 μL, chromatographic response monitored at 273 nm. The developed method was validated as per the ICH guidelines and found precise, accurate, and linear. The advantage of the method is a good separation of ALV isomers within 35 minutes of the analysis time. Therefore, this method is suitable for routine determination of chiral purity of ALV active pharmaceutical ingredient.  相似文献   

10.
The 5 alpha-stanol-3 beta-ol analogs of cholesterol, campesterol and beta-sitosterol along with many other sterol types were resolved using a Supelcowax 10 (Bonded Carbowax PEG 20M) fused silica capillary column (15 m x 0.25 mm). Unlike non-polar capillary columns, the semi-polar Carbowax liquid phase retains the unsaturated sterols longer than the corresponding saturated sterols, allowing an orderly elution and quantitation. The unnatural epicholestanol (5 alpha-cholestan-3 alpha-ol) was used as internal standard. By this method the stanol content of human plasma and of the unsaponifiable matter of dietary fats and oils is readily determined. Because of low column bleed the Supelcowax 10 liquid phase can be used for combined GC/MS analysis.  相似文献   

11.
Chiral mesoporous silica (CMS) has attracted widespread attention because of some unique properties, such as high surface area, uniformly structured nanoscale cavities, and excellent chemical and thermal stability. In this work, we report the utilization of a CMS as the stationary phase for the separation of racemates in gas chromatography (GC). A CMS‐coated capillary column was fabricated by a dynamic coating method. Eighteen racemates belonging to different classes of organic compounds were separated on this column, including chiral alcohols, aldehydes, ketones, organic acids, halohydrocarbons, alkenes, alcohol amines, epoxides, and amino acid derivatives. In addition, linear alkanes, alcohols, and aromatic hydrocarbons have also been resolved.  相似文献   

12.
The drug chirality is attracting increasing attention because of different biological activities, metabolic pathways, and toxicities of chiral enantiomers. The chiral separation has been a great challenge. Optimized high‐performance liquid chromatography (HPLC) methods based on vancomycin chiral stationary phase (CSP) were developed for the enantioseparation of propranolol, atenolol, metoprolol, venlafaxine, fluoxetine, and amlodipine. The retention and enantioseparation properties of these analytes were investigated in the variety of mobile phase additives, flow rate, and column temperature. As a result, the optimal chromatographic condition was achieved using methanol as a main mobile phase with triethylamine (TEA) and glacial acetic acid (HOAc) added as modifiers in a volume ratio of 0.01% at a flow rate of 0.3 mL/minute and at a column temperature of 5°C. The thermodynamic parameters (eg, ΔH, ΔΔH, and ΔΔS) from linear van 't Hoff plots revealed that the retention of investigated pharmaceuticals on vancomycin CSP was an exothermic process. The nonlinear behavior of lnk′ against 1/T for propranolol, atenolol, and metoprolol suggested the presence of multiple binding mechanisms for these analytes on CSP with variation of temperature. The simulated interaction processes between vancomycin and pharmaceutical enantiomers using molecular docking technique and binding energy calculations indicated that the calculated magnitudes of steady combination energy (ΔG) coincided with experimental elution order for most of these enantiomers.  相似文献   

13.
In the present study, hydroxypropyl‐β‐cyclodextrin and an ionic liquid (1‐ethyl‐3‐methylimidazolium‐l ‐lactate) were used as additives in capillary electrophoresis for the enantioseparation of 10 analytes, including ofloxacin, propranolol hydrochloride, dioxopromethazine hydrochloride, isoprenaline hydrochloride, chlorpheniramine maleate, liarozole, tropicamide, amlodipine benzenesulfonate, brompheniramine maleate, and homatropine methylbromide. The effects of ionic liquid concentrations, salt effect, cations, and anions of ionic liquids on enantioseparation were investigated and the results proved that there was a synergistic effect between hydroxypropyl‐β‐cyclodextrin and the ionic liquid, and the cationic part of the ionic liquid played an important role in the increased resolution. With the developed dual system, all the enantiomers of 10 analytes were well separated in resolutions of 5.35, 1.76, 1.85, 2.48, 2.88, 1.43, 5.45, 4.35, 2.76, and 2.98, respectively. In addition, the proposed method was applied to the determination of the enantiomeric purity of S‐ofloxacin after validation of the method in terms of selectivity, repeatability, linearity range, accuracy, precision, limit of detection (LOD), and limit of quality (LOQ). Chirality 25:409–414, 2013. © 2013 Wiley Periodicals, Inc.  相似文献   

14.
There is a demand of novel high resolution separation media for separation of complex mixtures, particularly biological samples. One of the most flexible techniques for development of new separation media currently is synthesis of the continuous bed (monolithic) stationary phases. In this study the capillary format gradient stationary phases were formed using continuous bed (monolith) polymerization in situ. Different reversed-phase stationary phase gradients were tailored and their resolution using capillary liquid chromatography and capillary electrochromatography at isocratic mobile phase conditions was evaluated. It is demonstrated, that efficiency and resolution of the gradient stationary phases can be substantially increased comparing to the common (isotropic) stationary phases. The proposed formation approach of the gradient stationary phase is reproducible and compatible with the capillary format or microchip format separations. It can be easily automated for the separation optimizations or mass production of the capillary columns or chips.  相似文献   

15.
Flecainide, an antiarrythmic agent, and its analogs were resolved on a high performance liquid chromatographic chiral stationary phase (CSP) based on (+)‐(18‐crown‐6)‐2,3,11,12‐tetracarboxylic acid with the use of a mobile phase consisting of methanol‐acetonitrile‐trifluoroacetic acid‐triethylamine (80/20/0.1/0.3, v/v/v/v). The chiral resolution was quite successful, the separation factors (α) and the resolutions (RS) for 20 analytes including flecainide being in the range of 1.19–1.82 and 1.73–6.80, respectively. The ortho‐substituent of the benzoyl group of analytes was found to cause decrease in the retention times of analytes probably because of the conformational deformation of analytes originated from the steric hindrance exerted by the ortho‐substituent. Chirality, 2010. © 2009 Wiley‐Liss, Inc.  相似文献   

16.
There is a demand of novel high resolution separation media for separation of complex mixtures, particularly biological samples. One of the most flexible techniques for development of new separation media currently is synthesis of the continuous bed (monolithic) stationary phases. In this study the capillary format gradient stationary phases were formed using continuous bed (monolith) polymerization in situ. Different reversed-phase stationary phase gradients were tailored and their resolution using capillary liquid chromatography and capillary electrochromatography at isocratic mobile phase conditions was evaluated. It is demonstrated, that efficiency and resolution of the gradient stationary phases can be substantially increased comparing to the common (isotropic) stationary phases. The proposed formation approach of the gradient stationary phase is reproducible and compatible with the capillary format or microchip format separations. It can be easily automated for the separation optimizations or mass production of the capillary columns or chips.  相似文献   

17.
Open‐tube volatile traps have largely been shunned in favor of solid adsorbent containing traps for the collection of volatile pheromones and attractants. Solid adsorbents require large solvent rinses and glass capillaries can be difficult to maneuver for the collection of volatiles from small or hard‐to‐reach odor sources. A gas chromatograph (GC) column (DB‐1), an open‐tube glass capillary, and a SuperQ®‐containing capillary were compared for their collection efficiencies from rubber septa and live calling insects. All three traps captured similar ratios of test compounds from septa at airflows >10 ml per min. Eluting analytes from a packed adsorbent, SuperQ, required at least 30× more solvent than was required to collect all the pheromone from the open‐tube glass capillaries, and the GC column enjoyed an additional three‐fold reduced solvent volume compared to the glass capillary. Thus, analytes could be eluted from the GC‐column trap and directly analyzed on GC without solvent evaporation. We placed glass wool ‘plugs’ in both GC columns and glass capillaries and found no volatiles in these plugs, indicating that breakthrough did not occur during 1‐h collections at 25 ml per min. We demonstrate here that at ambient laboratory temperatures, a DB‐1 GC column effectively collects Oriental fruit moth sex pheromone volatiles from a rubber septum and live pheromone‐releasing moths. Release ratios of pheromone from rubber septa are consistent with earlier reports from static air systems, whereas the release ratio of the (Z)‐8‐dodecenyl alcohol (Z8‐12:OH) from female Grapholita molesta Busck (Lepidoptera: Tortricidae) differed from published results and is likely due to different collection methods or moth‐strain origin.  相似文献   

18.
Through the adoption of a chiral stationary phase in high-performance liquid chromatography and a simple derivatization method for hydroxy fatty acids, it became easy to separate and identify the optical isomers of 2- and 3-hydroxy fatty acids composing several kinds of microbial lipids. The 2- and 3-hydroxy fatty acids were converted with dinitrophenyl isocyanate to their 3, 5-dinitrophenyl urethane derivatives (DU-derivatives), which were analyzable by HPLC using a chiral column. By varying the composition of an eluent, separation of the DU-derivatives of hydroxy fatty acids differing in optical configuration, chain length and position of hydroxyl group was achieved. The general elution orders of these DU-derivatives were determined with authentic 2- and 3-hydroxy fatty acids. Small amounts (~300 μg) of ornithine-containing lipids isolated from the Serratia marcescens strains were examined by this method to identify 3-hydroxy fatty acids of the lipids as D isomers.  相似文献   

19.
Rapid and simple isocratic high‐performance liquid chromatographic methods with UV detection were developed and validated for the direct resolution of racemic mixtures of hyoscyamine sulfate and zopiclone. The method involved the use of αl‐acid glycoprotein (AGP) as chiral stationary phase. The stereochemical separation factor (?) and the stereochemical resolution factor (Rs) obtained were 1.29 and 1.60 for hyoscyamine sulfate and 1.47 and 2.45 for zopiclone, respectively. The method was used for determination of chiral switching (eutomer) isomers: S‐hyoscyamine sulfate and eszopiclone. Several mobile phase parameters were investigated for controlling enantioselective retention and resolution on the chiral AGP column. The influence of mobile phase, concentration and type of uncharged organic modifier, ionic strength, and column temperature on enantioselectivity were studied. Calibration curves were linear in the ranges of 1–10 µg mL‐1 and 0.5–5 µg mL‐1 for S‐hyoscyamine sulfate and eszopiclone, respectively. The method is specific and sensitive, with lower limits of detection and quantifications of 0.156, 0.515 and 0.106, 0.349 for S‐hyoscyamine sulfate and eszopiclone, respectively. The method was used to identify quantitatively the enantiomers profile of the racemic mixtures of the studied drugs in their pharmaceutical preparations. Thermodynamic studies were performed to calculate the enthalpic ΔH and entropic ΔS terms. The results showed that enantiomer separation of the studied drugs were an enthalpic process. Chirality 28:49–57, 2016. © 2015 Wiley Periodicals, Inc.  相似文献   

20.
Ionic liquids in the form of organic salts are being widely used as new solvent media. In this paper three positional isomers,o-amino benzoic acid,m-amino benzoic acid, andp-amino benzoic acids were separated with four different ionic liquids as mobile phase additives using high performance liquid chromatography (HPLC). The following ionic liquids were used: 1-butyl-3-methylimidazolium tetrafluoroborate ([BMIm][BF4]), 1-ethyl-3-methylimidazolium tetrafluoroborate ([EMIm][BF4]), 1-ethyl-3-methylimidazolium methylsulfate ([EMIm][MS]), and 1-octyl-3-methylimidazolium methylsulfate ([OMIm][MS]). The effects of the alkyl group length on the imidazolium ring and its counterion, and the concentrations of the ionic liquids on the retention factors and resolutions of amino benzoic acid isomers were tested. The results of the separations with ionic liquids as the eluents were better than those without ionic liquids. Excellent separations of the three isomers were achieved using 2.0≈8.0 mM/L [OMIm][MS] and 1.0≈8.0 mM/L [EMIm][MS] as the eluent modifiers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号