首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Alternating tangential flow (ATF) filtration has been used with success in the Biopharmaceutical industry as a lower shear technology for cell retention with perfusion cultures. The ATF system is different than tangential flow filtration; however, in that reverse flow is used once per cycle as a means to minimize fouling. Few studies have been reported in the literature that evaluates ATF and how key system variables affect the rate at which ATF filters foul. In this study, an experimental setup was devised that allowed for determination of the time it took for fouling to occur for given mammalian (PER.C6) cell culture cell densities and viabilities as permeate flow rate and antifoam concentration was varied. The experimental results indicate, in accordance with D'Arcy's law, that the average resistance to permeate flow (across a cycle of operation) increases as biological material deposits on the membrane. Scanning electron microscope images of the post‐run filtration surface indicated that both cells and antifoam micelles deposit on the membrane. A unique mathematical model, based on the assumption that fouling was due to pore blockage from the cells and micelles in combination, was devised that allowed for estimation of sticking factors for the cells and the micelles on the membrane. This model was then used to accurately predict the increase in transmembane pressure during constant flux operation for an ATF cartridge used for perfusion cell culture. © 2014 American Institute of Chemical Engineers Biotechnol. Prog., 30:1291–1300, 2014  相似文献   

2.
High cell density perfusion process of antibody producing CHO cells was developed in disposable WAVE Bioreactor? using external hollow fiber filter as cell separation device. Both “classical” tangential flow filtration (TFF) and alternating tangential flow system (ATF) equipment were used and compared. Consistency of both TFF‐ and ATF‐based cultures was shown at 20–35 × 106 cells/mL density stabilized by cell bleeds. To minimize the nutrients deprivation and by‐product accumulation, a perfusion rate correlated to the cell density was applied. The cells were maintained by cell bleeds at density 0.9–1.3 × 108 cells/mL in growing state and at high viability for more than 2 weeks. Finally, with the present settings, maximal cell densities of 2.14 × 108 cells/mL, achieved for the first time in a wave‐induced bioreactor, and 1.32 × 108 cells/mL were reached using TFF and ATF systems, respectively. Using TFF, the cell density was limited by the membrane capacity for the encountered high viscosity and by the pCO2 level. Using ATF, the cell density was limited by the vacuum capacity failing to pull the highly viscous fluid. Thus, the TFF system allowed reaching higher cell densities. The TFF inlet pressure was highly correlated to the viscosity leading to the development of a model of this pressure, which is a useful tool for hollow fiber design of TFF and ATF. At very high cell density, the viscosity introduced physical limitations. This led us to recommend cell densities under 1.46 × 108 cell/mL based on the analysis of the theoretical distance between the cells for the present cell line. © 2013 American Institute of Chemical Engineers Biotechnol. Prog., 29:754–767, 2013  相似文献   

3.
A high cell density perfusion process of monoclonal antibody (MAb) producing Chinese hamster ovary (CHO) cells was developed in disposable WAVE Bioreactor? using external hollow fiber (HF) filter as cell separation device. Tangential flow filtration (TFF) and alternating tangential flow (ATF) systems were compared and process applications of high cell density perfusion were studied here: MAb production and cryopreservation. Operations by perfusion using microfiltration (MF) or ultrafiltration (UF) with ATF or TFF and by fed‐batch were compared. Cell densities higher than 108 cells/mL were obtained using UF TFF or UF ATF. The cells produced comparable amounts of MAb in perfusion by ATF or TFF, MF or UF. MAbs were partially retained by the MF using ATF or TFF but more severely using TFF. Consequently, MAbs were lost when cell broth was discarded from the bioreactor in the daily bleeds. The MAb cell‐specific productivity was comparable at cell densities up to 1.3 × 108 cells/mL in perfusion and was comparable or lower in fed‐batch. After 12 days, six times more MAbs were harvested using perfusion by ATF or TFF with MF or UF, compared to fed‐batch and 28× more in a 1‐month perfusion at 108 cells/mL density. Pumping at a recirculation rate up to 2.75 L/min did not damage the cells with the present TFF settings with HF short circuited. Cell cryopreservation at 0.5 × 108 and 108 cells/mL was performed using cells from a perfusion run at 108 cells/mL density. Cell resuscitation was very successful, showing that this system was a reliable process for cell bank manufacturing. © 2013 American Institute of Chemical Engineers Biotechnol. Prog., 29:768–777, 2013  相似文献   

4.
Alternating tangential flow filtration (ATF) has become one of the primary methods for cell retention and clarification in perfusion bioreactors. However, membrane fouling can cause product sieving losses that limit the performance of these systems. This study used scanning electron microscopy and energy dispersive X-ray spectroscopy to identify the nature and location of foulants on 0.2 μm polyethersulfone hollow fiber membranes after use in industrial Chinese hamster ovary cell perfusion bioreactors for monoclonal antibody production. Membrane fouling was dominated by proteinaceous material, primarily host cell proteins along with some monoclonal antibody. Fouling occurred primarily on the lumen surface with much less protein trapped within the depth of the fiber. Protein deposition was also most pronounced near the inlet/exit of the hollow fibers, which are the regions with the greatest flux (and transmembrane pressure) during the cyclical operation of the ATF. These results provide important insights into the underlying phenomena governing the fouling behavior of ATF systems for continuous bioprocessing.  相似文献   

5.
A novel approach of design of experiment (DoE) is developed for the optimization of key substrates of the culture medium, amino acids, and sugars, by utilizing perfusion microbioreactors with 2 mL working volume, operated in high cell density continuous mode, to explore the design space. A mixture DoE based on a simplex-centroid is proposed to test multiple medium blends in parallel perfusion runs, where the amino acids concentrations are selected based on the culture behavior in presence of different amino acid mixtures, and using targeted specific consumption rates. An optimized medium is identified with models predicting the culture parameters and product quality attributes (G0 and G1 level N-glycans) as a function of the medium composition. It is then validated in runs performed in perfusion microbioreactor in comparison with stirred-tank bioreactors equipped with alternating tangential flow filtration (ATF) or with tangential flow filtration (TFF) for cell separation, showing overall a similar process performance and N-glycosylation profile of the produced antibody. These results demonstrate that the present development strategy generates a perfusion medium with optimized performance for stable Chinese hamster ovary (CHO) cell cultures operated with very high cell densities of 60 × 106 and 120 × 106 cells/mL and a low cell-specific perfusion rate of 17 pL/cell/day, which is among the lowest reported and is in line with the framework recently published by the industry.  相似文献   

6.
This article reports the results obtained from comparison of internal spin filter (ISF) and alternating flow filtration (ATF) as cell retention systems, regarding cell growth, volumetric perfusion rate, cell specific perfusion rate and cell productivity in the fermentation process. As expected we were able to reach higher cell densities and to achieve longer runs since ATF systems are known to be less affected by fouling. Volumetric production of the reactor using the ATF system was 50‐70% higher than the production achieved using the ISF due to higher cell density and a two‐fold increase in the perfusion rate. On the other hand, downstream processing performances were evaluated regarding chromatographic steps yields and productivity and quality attributes of the purified materials. Similar results were obtained for all evaluated systems. The fact that we were able to achieve a 2 working volumes (WV)/day perfusion rate using an ATF system as cell retention device allowed us to virtually double the WV of a 25 L reactor. These results constitute valuable data for the optimization of recombinant protein production in perfusion processes since a two‐fold increase in the average production of a manufacturing facility could be easily achieved as long as downstream scale up is possible. © 2017 American Institute of Chemical Engineers Biotechnol. Prog., 33:1010–1014, 2017  相似文献   

7.
Bioprocess intensification can be achieved through high cell density perfusion cell culture with continuous protein capture integration. Protein passage and cell retention are commonly accomplished using tangential flow filtration systems consisting of microporous membranes. Significant challenges, including low efficiency and decaying product sieving over time, are commonly observed in these cell retention devices. Here, we demonstrate that a macroporous membrane overcomes the product sieving challenges when comparing to several other membrane chemistries and pore sizes within the microporous range. This way, variable chromatography column loading is avoided. The macroporous membrane yielded a 13,000 L/m2 volumetric throughput. The membrane's cut-off size results in an increased permeate turbidity due to particles passage, such as cell debris, through pores ranging from 1 to 4 µm. In addition, successful chromatography column plugging mitigation was achieved by employing depth filtration before the chromatographic step. Depth filtration volumetric throughputs were between 600 and 1,000 L/m2. Combing a macroporous cell retention device with a depth filter not only provided an alternative to address the challenge of undesired long protein residence times in the bioreactor due to product sieving decay, but also exhibited a throughput increase, making the integration of multicolumn capture chromatography with a perfusion cell culture a more robust process.  相似文献   

8.
In this study, we investigated the effects of alternating tangential flow (ATF) cell separation on high-density perfusion cultures. We have developed methods to estimate theoretical residence times of cells in the ATF system and discovered that long residence times (above 75 s) correlate with decreased growth, metabolism, and productivity. We have calculated energy dissipation rates in the ATF transfer line and filter and empirically studied the impacts of increased exchange rates on cell culture, determining that increased hydrodynamic stress can lead to decreased cell size, lactate production, and specific productivity. Finally, we have conducted experiments to understand the relationship between filtration fluxes and ATF membrane fouling, finding that at fluxes above 60 L·m–2·day –1, protein sieving coefficients see significant rates of decrease (greater than 1% per day). While most of these studies have been conducted with one cell line at one target viable cell density (40 million cells/ml), the general, directional knowledge arising from this study should be applicable to other conditions and programs, ultimately leading to more robust and well-designed perfusion processes.  相似文献   

9.
The availability of material for experimental studies is a key constraint in the development of full-scale bioprocesses. This is especially true for the later stages in a bioprocess sequence such as purification and formulation, where the product is at a relatively high concentration and traditional scale-down models can require significant volumes. Using a combination of critical flow regime analysis, bioprocess modelling, and experimentation, ultra scale-down (USD) methods can yield bioprocess information using only millilitre quantities before embarking on highly demanding full-scale studies. In this study the performance of a pilot-scale tangential flow filtration (TFF) system based on a membrane flat-sheet cassette using pumped flow was predicted by devising an USD device comprising a stirred cell using a rotating disc. The USD device operates with just 2.1 cm2 of membrane area and, for example, just 1.7 mL of feed for diafiltration studies. The novel features of the design involve optimisation of the disc location and the membrane configuration to yield an approximately uniform shear rate. This is characterised using computational fluid dynamics for a defined layer above the membrane surface. A pilot-scale TFF device operating at ~500-fold larger feed volume and membrane area was characterised in terms of the shear rate derived from flow rate-pressure drop relationships for the cassette. Good agreement was achieved between the USD and TFF devices for the flux and resistance values at equivalent average shear rates for a monoclonal antibody diafiltration stage.  相似文献   

10.
Perfusion culture is often performed with micro-sparger to fulfill the high oxygen demand from the densified cells. Protective additive Pluronic F-68 (PF-68) is widely used to mitigate the adverse effect in cell viability from micro-sparging. In this study, different PF-68 retention ratio in alternating tangential filtration (ATF) columns was found to be crucial for cell performance of different perfusion culture modes. The PF-68 in the perfusion medium was found retained inside the bioreactor when exchanged through ATF hollow fibers with a small pore size (50 kD). The accumulated PF-68 could provide sufficient protection for cells under micro-sparging. On the other hand, with large-pore-size (0.2 μm) hollow fibers, PF-68 could pass through the ATF filtration membranes with little retention, and consequently led to compromised cell growth. To overcome the defect, a PF-68 feeding strategy was designed and successfully verified on promoting cell growth with different Chinese hamster ovary (CHO) cell lines. With PF-68 feeding, enhancements were observed in both viable cell densities (20%–30%) and productivity (~30%). A threshold PF-68 concentration of 5 g/L for high-density cell culture (up to 100 × 106 cells/mL) was also proposed and verified. The additional PF-68 feeding was not observed to affect product qualities. By designing the PF-68 concentration of perfusion medium to or higher than the threshold level, a similar cell growth enhancement was also achieved. This study systematically investigated the protecting role of PF-68 in intensified CHO cell cultures, shedding a light on the optimization of perfusion cultures through the control of protective additives.  相似文献   

11.

A live-attenuated, human vaccine against mosquito-borne yellow fever virus has been available since the 1930s. The vaccine provides long-lasting immunity and consistent mass vaccination campaigns counter viral spread. However, traditional egg-based vaccine manufacturing requires about 12 months and vaccine supplies are chronically close to shortages. In particular, for urban outbreaks, vaccine demand can be covered rarely by global stockpiling. Thus, there is an urgent need for an improved vaccine production platform, ideally transferable to other flaviviruses including Zika virus. Here, we present a proof-of-concept study regarding cell culture-based yellow fever virus 17D (YFV) and wild-type Zika virus (ZIKV) production using duck embryo-derived EB66® cells. Based on comprehensive studies in shake flasks, 1-L bioreactor systems were operated with scalable hollow fiber-based tangential flow filtration (TFF) and alternating tangential flow filtration (ATF) perfusion systems for process intensification. EB66® cells grew in chemically defined medium to cell concentrations of 1.6 × 108 cells/mL. Infection studies with EB66®-adapted virus led to maximum YFV titers of 7.3 × 108 PFU/mL, which corresponds to about 10 million vaccine doses for the bioreactor harvest. For ZIKV, titers of 1.0 × 1010 PFU/mL were achieved. Processes were automated successfully using a capacitance probe to control perfusion rates based on on-line measured cell concentrations. The use of cryo-bags for direct inoculation of production bioreactors facilitates pre-culture preparation contributing to improved process robustness. In conclusion, this platform is a powerful option for next generation cell culture-based flavivirus vaccine manufacturing.

  相似文献   

12.
Mammalian cells were grown to high density in a 3,000 L culture using perfusion with hollow fibers operated in a tangential flow filtration mode. The high-density culture was used to inoculate the production stage of a biomanufacturing process. At constant permeate flux operation, increased transmembrane pressures (TMPs) were observed on the final day of the manufacturing batches. Small scale studies suggested that the filters were not irreversibly fouled, but rather exposed to membrane concentration polarization that could be relieved by tangential sweeping of the hollow fibers. Studies were undertaken to analyze parameters that influence the hydrodynamic profile within hollow fibers; including filter area, cell density, recirculation flow rate, and permeate flow rate. Results indicated that permeate flow rate had the greatest influence on modulating TMP. Further evaluation showed a significant decrease in TMP when permeate flow was reduced, and this occurred without any negative effect on cell growth or viability. Hence, a 30% reduction of permeate flow rate was implemented at manufacturing scale. A stable operation was achieved as TMP was successfully reduced by 75% while preserving all critical factors for performance in the perfusion bioreactor.  相似文献   

13.
In this study, a filtration-based perfusion process was developed for the production of monoclonal antibodies (IgM) by suspended hybridoma cells grown in protein-free medium. It was found that the use of protein-free medium for perfusion culture generated the formation of numerous visible suspended particles consisting of dead cells and cellular debris aggregated into fibrous material. Surprisingly high apparent viabilities were observed in such protein-free cultures. In addition, membrane fouling occurred more rapidly in protein-free medium than in conventional serum-supplemented medium. By the addition of deoxyribonuclease I (DNase I) to the protein-free medium, it was possible to prevent the formation of aggregates and to follow the evolution of the total cell population more accurately. Moreover, DNase I significantly reduced the fouling of filtration membranes, and that, for two different types of separation systems (cross-flow and vortex-flow filtration) and two different types of membranes (polycarbonate and hydrophilized polysultone). From these results, it is clear that the presence of DNA fragments liberated following cellular death is playing an important role in membrane fouling. Longevity of filtration membranes was found to be considerably greater using a vortex-flow filtration module than with a static plate-and-frame cross-flow filtration module. The use of vortex-flow filtration of conjuction with DNase I allowed maintenance of perfusion cultures for more than 1 month without membrane fouling or antibody retention and with a constant permeate IgM concentration of 250 mg/L. Hybridomacells appeared to gradually adapt to increasing rotational speed in the vortex-flow filtration module.  相似文献   

14.
Although several compelling benefits for bioprocess intensification have been reported, the need for a streamlined integration of perfusion cultures with capture chromatography still remains unmet. Here, a robust solution is established by conducting tangential flow filtration-based perfusion with a wide-surface pore microfiltration membrane. The resulting integrated continuous bioprocess demonstrated negligible retention of antibody, DNA, and host cell proteins in the bioreactor with average sieving coefficients of 98 ± 1%, 124 ± 28%, and 109 ± 27%, respectively. Further discussion regarding the potential membrane fouling mechanisms is also provided by comparing two membranes with different surface pore structures and the same hollow fiber length, total membrane area, and chemistry. A cake-growth profile is reported for the narrower surface pore, 0.65-µm nominal retention perfusion membrane with final antibody sieving coefficients ≤70%. Whereas the sieving coefficient remained ≥85% during 40 culture days for the wide-surface pore, 0.2-µm nominal retention rating membrane. The wide-surface pore structure, confirmed by scanning electron microscopy imaging, minimizes the formation of biomass deposits on the membrane surface and drastically improves product sieving. This study not only offers a robust alternative for integrated continuous bioprocess by eliminating additional filtration steps while overcoming sieving decay, but also provides insight into membranes' fouling mechanism.  相似文献   

15.
High performance tangential flow filtration   总被引:2,自引:0,他引:2  
Conventional tangential flow filtration (TFF) has traditionally been limited to separation of solutes that differ by about ten-fold in size. Wide pore-size distributions, membrane fouling, and concentration polarization phenomena have commonly been cited as reasons for this limitation. The use of TFF in the biotechnology industry has therefore been restricted to cell-protein, virus-protein, and protein-buffer separations. A multi-disciplinary team with industrial and academic members was formed to overcome these limitations and enable protein-protein separations using High Performance TFF (HPTFF) systems. Pore-size distributions have been improved with the development of new membrane formulation and casting techniques. Membrane fouling has been controlled by operating in the transmembrane pressure-dependent regime of the filtrate flux curve and by carefully controlling fluid dynamic start-up conditions. Concentration polarization was exploited to enhance, rather than limit, the resolution of solutes. Concentration polarization has also been controlled by operating a co-current filtrate stream that maintains transmembrane pressure constant along the length of the TFF module. High yields and purification factors were obtained even with small differences in protein sieving. IgG-BSA and BSA monomer-oligomer mixtures have successfully been separated with these systems. HPTFF technology provides a competitive purification tool to complement chromatographic processing of proteins. (c) 1997 John Wiley & Sons, Inc. Biotechnol Bioeng 56: 71-82, 1997.  相似文献   

16.
An alternating tangential flow (ATF) perfusion-based transient gene expression (TGE) bioprocess has been developed using human embryonic kidney (HEK) 293 cells to produce H1-ss-np, a promising candidate for a universal influenza vaccine. Two major adjustments were taken to improve the process: (1) eliminate the interference of microbubbles during gene transfection; and (2) utilize an ATF perfusion system for a prolonged culture period. As a result, a closed-operation 9-days ATF perfusion-based TGE bioprocess was developed. The TGE bioprocess showed continuous cell growth with high cell viability and prolonged cellular productivity that achieved recombinant product level of ~270 mg/L which was more than two times that of 4-days base-line TGE bioprocess. In addition, the consumables cost per milligram for ATF perfusion-based TGE bioprocess was ~70% lower than that of the base-line TGE bioprocess suggesting high cost savings potential in vaccine manufacturing. Based on the lower contamination risk, higher productivity, and cost efficiency, the ATF perfusion-based TGE bioprocess can likely provide potential benefits to many future applications in vaccine and drug manufacturing.  相似文献   

17.
Opportunities for process intensification have made continuous biomanufacturing an area of active research. While tangential flow filtration (TFF) is typically employed within the biologics purification train to increase drug substance concentration, single-pass TFF (SPTFF) modifies its format by enabling continuity of this process and achieving a multifold concentration factor through a single-pass over the filtration membranes. In continuous processes feed concentration and flow rate are determined by the preceding unit operations. Therefore, tight control of SPTFF output concentration must be achieved through precise design of the membrane configuration, unlike TFF. However, predictive modeling can be utilized to identify configurations that achieve a desired target concentration across ranges of possible feed conditions with minimal experimental data, hence enabling accelerated process development and design flexibility. We hereby describe the development of a mechanistic model predicting SPTFF performance across a wide design space using the well-established stagnant film model, which we demonstrate is more accurate at higher feed flow rates. The flux excursion dataset was generated within time constraints and with minimal material consumption, showing the method's ability to be quickly adapted. While this approach eliminates characterizing complex physicochemical model variables or the need for users with specialized training, the model and its assumptions become inaccurate at low flow rates, below 25 L/m2/h, and high conversions, above 0.9. As this low flow rate, high conversion operating regime is relevant for continuous biomanufacturing, we explore the assumptions and challenges involved in predicting and modeling SPTFF processes, while suggesting added characterization to gain further process insight.  相似文献   

18.
Tangential flow filtration is advantageous for bioreactor clarification as the permeate stream could be introduced directly to the subsequent product capture step. However, membrane fouling coupled with high product rejection has limited its use. Here, the performance of a reverse asymmetric hollow fiber membrane where the more open pore structure faces the feed stream and the barrier layer faces the permeate stream has been investigated. The open surface contains pores up to 40 μm in diameter while the tighter barrier layer has an average pore size of 0.4 μm. Filtration of Chinese hamster ovary cell feed streams has been investigated under conditions that could be expected in fed batch operations. The performance of the reverse asymmetric membrane is compared to that of symmetric hollow fiber membranes with nominal pore sizes of 0.2 and 0.65 μm. Laser scanning confocal microscopy was used to observe the locations of particle entrapment. The throughput of the reverse asymmetric membrane is significantly greater than the symmetric membranes. The membrane stabilizes an internal high permeability cake that acts like a depth filter. This stabilized cake can remove particulate matter that would foul the barrier layer if it faced the feed stream. An empirical model has been developed to describe the variation of flux and transmembrane pressure drop during filtration using reverse asymmetric membranes. Our results suggest that using a reverse asymmetric membrane could avoid severe flux decline associated with fouling of the barrier layer during bioreactor clarification.  相似文献   

19.
This article evaluates the current and future potential of batch and continuous cell culture technologies via a case study based on the commercial manufacture of monoclonal antibodies. The case study compares fed‐batch culture to two perfusion technologies: spin‐filter perfusion and an emerging perfusion technology utilizing alternating tangential flow (ATF) perfusion. The operational, economic, and environmental feasibility of whole bioprocesses based on these systems was evaluated using a prototype dynamic decision‐support tool built at UCL encompassing process economics, discrete‐event simulation and uncertainty analysis, and combined with a multi‐attribute decision‐making technique so as to enable a holistic assessment. The strategies were compared across a range of scales and titres so as to visualize how their ranking changes in different industry scenarios. The deterministic analysis indicated that the ATF perfusion strategy has the potential to offer cost of goods savings of 20% when compared to conventional fed‐batch manufacturing processes when a fivefold increase in maximum viable cell densities was assumed. Savings were also seen when the ATF cell density dropped to a threefold increase over the fed‐batch strategy for most combinations of titres and production scales. In contrast, the fed‐batch strategy performed better in terms of environmental sustainability with a lower water and consumable usage profile. The impact of uncertainty and failure rates on the feasibility of the strategies was explored using Monte Carlo simulation. The risk analysis results demonstrated the enhanced robustness of the fed‐batch process but also highlighted that the ATF process was still the most cost‐effective option even under uncertainty. The multi‐attribute decision‐making analysis provided insight into the limited use of spin‐filter perfusion strategies in industry. The resulting sensitivity spider plots enabled identification of the critical ratio of weightings of economic and operational benefits that affect the choice between ATF perfusion and fed‐batch strategies. Biotechnol. Bioeng. 2013; 110: 206–219. © 2012 Wiley Periodicals, Inc.  相似文献   

20.
The use of bioreactors coupled to membrane-based perfusion systems enables very high cell and product concentrations in vaccine and viral vector manufacturing. Many virus particles, however, are not stable and either lose their infectivity or physically degrade resulting in significant product losses if not harvested continuously. Even hollow fiber membranes with a nominal pore size of 0.2 µm can retain much smaller virions within a bioreactor. Here, we report on a systematic study to characterize structural and physicochemical membrane properties with respect to filter fouling and harvesting of yellow fever virus (YFV; ~50 nm). In tangential flow filtration perfusion experiments, we observed that YFV retention was only marginally determined by nominal but by effective pore sizes depending on filter fouling. Evaluation of scanning electron microscope images indicated that filter fouling can be reduced significantly by choosing membranes with (i) a flat inner surface (low boundary layer thickness), (ii) a smooth material structure (reduced deposition), (iii) a high porosity (high transmembrane flux), (iv) a distinct pore size distribution (well-defined pore selectivity), and (v) an increased fiber wall thickness (larger effective surface area). Lowest filter fouling was observed with polysulfone (PS) membranes. While the use of a small-pore PS membrane (0.08 µm) allowed to fully retain YFV within the bioreactor, continuous product harvesting was achieved with the large-pore PS membrane (0.34 µm). Due to the low protein rejection of the latter, this membrane type could also be of interest for other applications, that is, recombinant protein production in perfusion cultures.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏