首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Bacteria detection using disposable optical leaky waveguide sensors   总被引:3,自引:0,他引:3  
Novel disposable absorbing material clad leaky waveguide sensor devices (LWD) have been developed for the detection of pathogenic particles such as bacteria. These chips are tailored to give the maximum extension of the evanescent field at the sensor surface in order to place the entire volume of the bacteria captured by immobilized antibodies on the chip surface within this field. This in turn increases the interaction of the light with the bacteria's bulk volume. Disposable LWD chips were fabricated at room temperature and without the use of expensive fabrication equipment. These LWDs have been characterised by detecting refractive index (RI) changes, scattering and fluorescence from bacterial spores at the sensor surface when illuminated at the coupling angle. The detection limit of Bacillus subtilis var. niger (BG) bacterial spores was 10(4) spores/ml and the illumination intensity of the spores was found to be three times greater than the illumination intensity generated using the surface plasmon resonance (SPR).  相似文献   

2.
In this paper, a high-sensitivity refractive index sensor based on a hybrid plasma waveguide and metal–insulator–metal waveguide combined third-order runway series mosaic microring resonator is proposed. In this structure, a GaAs waveguide ring surrounds a gold waveguide ring in the middle, and the innermost layer is a disk made of gold material. The outer groove waveguide is composed of GaAs-air-alloy, and the inner groove waveguide is made of the Gold-Air-Gold material disc. By filling different substances in the groove, the change of refractive index will affect the optical signal strength of the output spectrum. The finite element method simulates the transmission spectrum and electric field distribution of the sensor structure. The amplitude coupling coefficient and attenuation factor affecting the resonator's performance are analyzed, and the structural parameters of the slot waveguide are optimized. The numerical simulation results show that the sensor quality factor of this structure is 1.54 × 104, the sensitivity is 1.2 × 103 nm/RIU which is about 1.5 times higher than that of the Si ring with the same structure, the detection limit can reach 8.1892 × 10−7 RIU, and the free spectral range can reach 109 nm. Compared with the traditional microring structure, this microring has higher design freedom and free spectral range and is more suitable for producing biosensors with high sensitivity, low detection limit, and multi-parameter measurement.  相似文献   

3.
The combination of various evanescent optical methods such as surface plasmon spectroscopy, waveguide mode spectroscopy and an integrated optical Mach-Zehnder-interferometer are used to characterize biotinylated self-assembled monolayers as well as the binding of streptavidin to these labels. The aim of designing a highly specific and sensitive, re-usable affinity sensor for antigens on the basis of an integrated optical Mach-Zehnder interferometer is based on a proper understanding of the characteristics of the entire binding matrix architecture. Therefore, a variety of biotin-derivatives immobilized in a monolayer are investigated with respect to their affinity to streptavidin and the possibility to remove the steptavidin layer specifically. The density of the streptavidin layer as well as the optical constants of the involved molecules are measured. Finally the integrated optical Mach-Zehnder interferometer is tested with respect to the sensitivity to an antigen-antibody binding reaction. An attempt to further increase the sensitivity by simultaneous detection of a fluorescence signal failed due to bleaching effects.  相似文献   

4.
The potential use of hydrazine sulfate was examined for the catalytic reduction of enzymatically generated H2O2 in a biosensor system. The performance of the hydrazine-based sensor was compared with an HRP-based glucose sensor as a model of a biosensor. Hydrazine and HRP were covalently immobilized onto a conducting polymer layer with glucose oxidase. The direct electron transfer reactions of the immobilized hydrazine and HRP onto the poly-5,2':5,2'-terthiophene-3'-carboxylic acid (poly-TTCA) layer were investigated by using cyclic voltammetric method and the electron transfer rate constants were determined. The glucose oxidase- and hydrazine-immobilized sensor efficiently reduced the enzymatically generated H2O2 at -0.15 V versus Ag/AgCl. The surface of this GOx/hydrazine/poly-TTCA-based glucose sensor was characterized by QCM, SEM, and ESCA. Glucose-sensing properties were studied using cyclic voltammetric and chronoamperometric techniques. Various experimental parameters were optimized according to the amount of hydrazine, pH, the temperature, and the applied potential. A linear calibration plot was obtained in the concentration range between 0.1 and 15.0 mM, and the detection limit was determined to be 40.0+/-7.0 microM. Interferences from other biological compounds were studied. The long-term stability of the GOx/hydrazine sensor was better than that of the one based on a GOx/HRP biosensor. The proposed glucose sensor was successfully applied to human whole blood and urine samples for the detection of glucose.  相似文献   

5.
We investigate the propagation characteristics of the fundamental surface plasmon polariton (SPP) mode of a finite-width metal–dielectric–metal waveguide. By changing the refractive index or the thickness of the dielectric layer of the waveguide, the SPP mode can be transformed from a mode confined in the dielectric layer into a mode confined around the metal corners. There always exists a condition at which the mode field distribution in the dielectric layer becomes almost perfectly uniform along the direction parallel to the metal layers, and this condition is insensitive to the width of the waveguide. It is also possible to obtain an ultra-uniform field distribution by controlling the refractive index of a different dielectric placed on both sides of the waveguide. The waveguide can be used as a basic structure for the realization of nanosized photonic devices and sensors.  相似文献   

6.
A surface plasmon resonance (SPR) waveguide immunosensor fabricated by germanium-doped silicon dioxide was investigated in this study. The designed waveguide sensor consisted of a 10 microm SiO(2) substrate layer (n=1.469), a 10 microm Ge-SiO(2) channel guide (n=1.492) and a 50 nm gold film layer for immobilization of biomolecules and SPR signal detection. The resultant spectral signal was measured by a portable spectrophotometer, where the sensor was aligned by a custom-designed micro-positioner. The results of the glycerol calibration standards showed that the resonance wavelength shifted from 628 to 758 nm due to changes of refractive index from 1.36 to 1.418. Flow-through immunoassay on waveguide sensors also showed the interactions of protein A, monoclonal antibody (mAb ALV-J) and avian leucosis virus (ALVs) resulted in wavelength shifting of 4.17, 3.03 and 2.18 nm, respectively. The SPR dynamic interaction could also be demonstrated successfully in 4 min as the sensor was integrated with a lateral flow nitrocellulose strip. These results suggest that SPR detection could be carried out on designed waveguide sensor, and the integration of nitrocellulose strip for sample filtering and fluid carrier would facilitate applications in point-of-care portable system.  相似文献   

7.
Genetically engineered periplasmic glucose receptors as biomolecular recognition elements on gold nanoparticles (AuNPs) have allowed our laboratory to develop a sensitive and reagentless electrochemical glucose biosensor. The receptors were immobilized on AuNPs by a direct sulfur-gold bond through a cysteine residue that was engineered in position 1 on the protein sequence. The study of the attachment of genetically engineered and wild-type proteins binding to the AuNPs was first carried out in colloidal gold solutions. These constructs were studied and characterized by UV-Vis spectroscopy, transmission electron microscopy, particle size distribution, and zeta potential. We show that the genetically engineered cysteine is important for the immobilization of the protein to the AuNPs. Fabrication of the novel electrochemical biosensor for the detection of glucose used these receptor-coated AuNPs. The sensor showed selective detection of glucose in the micromolar concentration range, with a detection limit of 0.18 microM.  相似文献   

8.
A sensitive optical waveguide lightmode spectroscopy-based immunosensor was developed to detect vitellogenin in seawater flatfish (Paralichthys olivaceus). For this purpose, anion-exchange column chromatography with DE-52 resin was used to purify flatfish vitellogenin from flatfish serum containing vitellogenin that had been induced using an intraperitoneal 17beta-estradiol injection. The anti-flatfish vitellogenin antibody used as the biological component of the above immunosensor was prepared using the purified flatfish vitellogenin. The change in the incoupling angle according to the complexation between the flatfish vitellogenin and its antibody, immobilized over an optical grating coupler sensor chip, was measured to calculate the sensor response. The immunosensor was quite specific to flatfish vitellogenin binding, based on no sensor response in the case of bovine serum albumin immobilization. When plotted using double-logarithmic scales, the sensor responses increased linearly in flatfish vitellogenin concentrations of 0.00675-67.5 nM, with a detection limit of 0.0675 nM. The reusability during seven repetitive measurements was reasonably fair for the preliminary screening of flatfish vitellogenin.  相似文献   

9.
Green fluorescent protein (GFP) is frequently utilized for metal ion detection and quantification. To improve the metal binding potential of GFP, three residues (N146, F165, and L201) were substituted to histidines. Each variant responded differently upon interaction with metal ions. More than 80% of N146H, having the most accessible surface area, could bind to immobilized metal ions. However, only F165H exhibited significant differences in quenching by soluble metal ions (22% fluorescence decrease) in comparison with the template protein (12%). These findings can be utilized for designing GFP variants for metal binding and sensor applications.  相似文献   

10.
Nanoscale porous silicon waveguide for label-free DNA sensing   总被引:3,自引:0,他引:3  
Porous silicon (PSi) is an excellent material for biosensing due to its large surface area and its capability for molecular size selectivity. In this work, we report the experimental demonstration of a label-free nanoscale PSi resonant waveguide biosensor. The PSi waveguide consists of pores with an average diameter of 20nm. DNA is attached inside the pores using standard amino-silane and glutaraldehyde chemistry. Molecular binding in the PSi is detected optically based on a shift of the waveguide resonance angle. The magnitude of the resonance shift is directly related to the quantity of biomolecules attached to the pore walls. The PSi waveguide sensor can selectively discriminate between complementary and non-complementary DNA. The advantages of the PSi waveguide biosensor include strong field confinement and a sharp resonance feature, which allow for high sensitivity measurements with a low detection limit. Simulations indicate that the sensor has a detection limit of 50nM DNA concentration or equivalently, 5pg/mm2.  相似文献   

11.
In this article, a phage-based magnetoelastic sensor for the detection of Salmonella typhimurium is reported. Filamentous bacteriophage specific to S. typhimurium was used as a biorecognition element in order to ensure specific and selective binding of bacteria onto the sensor surface. Phage was immobilized onto the surface of the sensors by physical adsorption. The phage immobilized magnetoelastic sensors were exposed to S. typhimurium cultures with different concentrations ranging from 5x10(1) to 5x10(8) cfu/ml, and the corresponding changes in resonance frequency response of the sensor were studied. It was experimentally established that the sensitivity of the magnetoelastic sensors was higher for sensors with smaller physical dimensions. An increase in sensitivity from 159 Hz/decade for a 2 mm sensor to 770 Hz/decade for a 1 mm sensor was observed. Scanning electron microscopy (SEM) analysis of previously assayed biosensors provided visual verification of frequency changes that were caused by S. typhimurium binding to phage immobilized on the sensor surface. The detection limit on the order of 10(3) cfu/ml was obtained for a sensor with dimensions 1x0.2x0.015 mm.  相似文献   

12.
A photonic crystal (PhC) waveguide based optical biosensor capable of label-free and error-corrected sensing was investigated in this study. The detection principle of the biosensor involved shifts in the resonant mode wavelength of nanocavities coupled to the silicon PhC waveguide due to changes in ambient refractive index. The optical characteristics of the nanocavity structure were predicted by FDTD theoretical methods. The device was fabricated using standard nanolithography and reactive-ion-etching techniques. Experimental results showed that the structure had a refractive index sensitivity of 10(-2) RIU. The biosensing capability of the nanocavity sensor was tested by detecting human IgG molecules. The device sensitivity was found to be 2.3±0.24×10(5) nm/M with an achievable lowest detection limit of 1.5 fg for human IgG molecules. Additionally, experimental results demonstrated that the PhC devices were specific in IgG detection and provided concentration-dependent responses consistent with Langmuir behavior. The PhC devices manifest outstanding potential as microscale label-free error-correcting sensors, and may have future utility as ultrasensitive multiplex devices.  相似文献   

13.
Ladder-shaped polyether (LSP) compounds represented by brevetoxins and ciguatoxins were largely discovered in association with seafood poisoning. Thus, a quick quantification method for LSPs is potentially important. We examined a surface plasmon resonance method using desulfated-yessotoxin (dsYTX) immobilized on a sensor chip and phosphodiesterase PDEII in a inhibition detection mode. Yessotoxin, brevetoxin B and synthetic LSP derivatives showed clear inhibition against PDEII binding to the immobilized dsYTX, by which their half inhibitory concentrations were successfully estimated. This inhibition method appeared to be superior in specificity to direct binding assays where binding proteins to LSP was immobilized on a sensor chip.  相似文献   

14.
Mercury ions (Hg(2+)) are a highly toxic and ubiquitous pollutants requiring rapid and sensitive on-site detection methods in the environment and foods. Herein, we report an envanescent wave DNA-based biosensor for rapid and very sensitive Hg(2+) detection based on a direct structure-competitive detection mode. In this system, a DNA probe covalently immobilized onto a fiber optic sensor contains a short common oligonucleotide sequences that can hybidize with a fluorescently labeled complementary DNA. The DNA probe also comprises a sequence of T-T mismatch pairs that binds with Hg(2+) to form a T-Hg(2+)-T complex by folding of the DNA segments into a hairpin structure. With a structure-competitive mode, a higher concentration of Hg(2+) leads to less fluorescence-labeled cDNA bound to the sensor surface and thus to lower fluorescence signal. The total analysis time for a single sample, including the measurement and surface regeneration, was under 6 min with a Hg(2+) detection limit of 2.1 nM. The high specificity of the sensor was demonstrated by evaluating its response to a number of potentially interfering metal ions. The sensor's surface can be regenerated with a 0.5% SDS solution (pH 1.9) over 100 times with no significant deterioration of performance. This platform is potentially applicable to detect other heavy metal ions or small-molecule analytes for which DNA/aptamers can be used as specific sensing probes.  相似文献   

15.
Sensitivity of Anthrax protective antigen (PA) detection has been improved by directly immobilizing a PA-specific peptide onto a multi-wall carbon nanotube (MWCNT). The MWCNT was covalently immobilized onto a polyaniline (PANI) electrode, which was prepared via electropolymerization of the aniline monomer onto a glassy carbon electrode (GCE). Then, the PA-specific peptide was covalently immobilized to the MWCNT layer for measurement. When comparing this technique to that of PA immobilization on an insulting self assembled organic layer, the advantages of the MWCNT are clear. The MWCNT sensor resulted in enhanced electron transfer across the sensing layer. The resulting limit of detection (LOD) was 0.4 pM, a 13-fold improvement over that of our previous self-assembled organic layer was used for immobilization of the same peptide. Neither positive nor negative interferences were observed when a sample containing both 100 pM PA and bovine serum albumin (BSA) was measured, indicating good selectivity of the proposed sensor.  相似文献   

16.
The filter function of the metal–insulator–metal (MIM) waveguide with a gear-shaped nanocavity is investigated using the finite-difference time-domain method. Since the gear breaks the symmetric distribution of the resonance, Fano resonance occurs in the gear-shaped nanocavity. Fano resonance strongly depends on the structural parameters of the gear. Compared to the MIM waveguide with a disk-shaped nanocavity, the MIM waveguide with a gear-shaped nanocavity allows for a much more sensitive detection of small refractive index changes of the filled media inside the nanocavity, which reveals a potential sensor application of the MIM waveguide with a gear-shaped nanocavity.  相似文献   

17.
A new protein sensor is demonstrated by replacing the gate of a metal oxide semiconductor field effect transistor (MOSFET) with a nano-interdigitated array (nIDA). The sensor is able to detect the binding reaction of a typical antibody Ixodes ricinus immunosuppressor (anti-Iris) protein at a concentration lower than 1 ng/ml. The sensor exhibits a high selectivity and reproducible specific detection. We provide a simple model that describes the behavior of the sensor and explains the origin of its high sensitivity. The simulated and experimental results indicate that the drain current of nIDA-gate MOSFET sensor is significantly increased with the successive binding of the thiol layer, Iris and anti-Iris protein layers. It is found that the sensor detection limit can be improved by well optimizing the geometrical parameters of nIDA-gate MOSFET. This nanobiosensor, with real-time and label-free capabilities, can easily be used for the detection of other proteins, DNA, virus and cancer markers. Moreover, an on-chip associated electronics nearby the sensor can be integrated since its fabrication is compatible with complementary metal oxide semiconductor (CMOS) technology.  相似文献   

18.
A novel immunosensing device based on a piezoelectric sensor for direct detection of the biological warfare agent Francisella tularensis was developed. This sensor includes mouse polyclonal antibody immobilized in a layer of protein A covalently linked to the gold electrode of the sensor. The immunosensor is able to detect F. tularensis with the limit of detection 10(5) CFU/mL with a typical measuring cycle > 5 min. The sensor was successfully evaluated for rapid detection of F. tularensis spikes in drinking water and milk; no deterioration of sensitivity in comparison with buffer solutions was observed. The proposed concept of a rapid measurement of microbial agents seems to be promising for evaluation of samples after short pre-cultivation enrichment.  相似文献   

19.
Indirectly heated electrodes operating in a non-isothermal mode have been used as transducers for reagentless glucose biosensors. Pyrroloquinoline quinone-dependent soluble glucose dehydrogenase (PQQ-sGDH) was entrapped on the electrode surface within a redox hydrogel layer. Localized polymer film precipitation was invoked by electrochemically modulating the pH-value in the diffusion zone in front of the electrode. The resulting decrease in solubility of an anodic electrodeposition paint (EDP) functionalized with Osmium complexes leads to precipitation of the redox hydrogel concomitantly entrapping the enzyme. The resulting sensor architecture enables a fast electron transfer between enzyme and electrode surface. The glucose sensor was operated at pre-defined temperatures using a multiple current-pulse mode allowing reproducible indirect heating of the sensor. The sensor characteristics such as the apparent Michaelis constants K(M)(app) and maximum currents I(max)(app) were determined at different temperatures for the main substrate glucose as well as a potential interfering co-substrate maltose. The limit of detection increased with higher temperatures for both substrates (0.020 mM for glucose, and 0.023 mM for maltose at 48 degrees C). The substrate specificity of PQQ-sGDH is highly temperature dependent. Therefore, a mathematical model based on a multiple linear regression approach could be applied to discriminate between the current response for glucose and maltose. This allowed accurate determination of glucose in a concentration range of 0-0.1mM in the presence of unknown maltose concentrations ranging from 0 to 0.04 mM.  相似文献   

20.
Periodic checks of fish health and the rapid detection of abnormalities are thus necessary at fish farms. Several studies indicate that blood glucose levels closely correlate to stress levels in fish and represent the state of respiratory or nutritional disturbance. We prepared a wireless enzyme sensor system to determine blood glucose levels in fish. It can be rapidly and conveniently monitored using the newly developed needle-type enzyme sensor, consisting of a Pt-Ir wire, Ag/AgCl paste, and glucose oxidase. To prevent the effects of interfering anionic species, such as uric acid and ascorbic acid, on the sensor response, the Pt-Ir electrode was coated with Nafion, and then glucose oxidase was immobilized on the coated electrode. The calibration curve of the glucose concentration was linear, from 0.18 to 144mg/dl, and the detection limit was 0.18mg/dl. The sensor was used to wirelessly monitor fish glucose levels. The sensor-calibrated glucose levels and actual blood glucose levels were in excellent agreement. The fluid of the inner sclera of the fish eyeball (EISF) was a suitable site for sensor implantation to obtain glucose sample. There was a close correlation between glucose concentrations in the EISF and those in the blood. Glucose concentrations in fish blood could be monitored in free-swimming fish in an aquarium for 3 days.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号