首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
AIM: The purpose of this study was to develop an empirically derived transport model, which could be used to predict downwind concentrations of viruses and bacteria during land application of liquid biosolids and subsequently assess microbial risk associated with this practice. METHODS AND RESULTS: To develop the model, coliphage MS-2 and Escherichia coli were aerosolized after addition to water within a biosolids spray application truck, and bioaerosols were collected at discrete downwind distances ranging from 2 to 70 m. Although coliphage were routinely detected, E. coli did not frequently survive aerosolization. Data on aerosolized coliphage was then used to generate a virus transport model. Risks of infection were calculated for various ranges of human virus concentrations that could be found in biosolids. CONCLUSIONS: A conservative estimate at 30.5 m (assumed to be nearest adjacent residences) downwind, resulted in risks of infection of 1 : 100,000, to the more realistic 1 : 10,000,000 per exposure. Conservative annual risks were calculated to be no more than 7 : 100,000 where as a more realistic risk was no greater than 7 : 10,000,000. Overall, the viral risk to residences adjacent to land application sites appears to be low, both for one time and annual probabilities of infection. SIGNIFICANCE AND IMPACT OF THE STUDY: This study demonstrated a simple approach towards modelling viral pathogens aerosolized from land applied liquid biosolids, and offers insight into the associated viral risk.  相似文献   

2.
Persistence of Salmonella typhimurium on Fabrics   总被引:3,自引:3,他引:0       下载免费PDF全文
The objective of this study was to determine the feasibility of using airborne T3 coliphage as a viral tracer in microbial aerosols. Although T3 coliphage was relatively stable when stored either at temperatures ranging from 21 to 37 C or in the frozen state at -20 C, there was a 2-log loss in infectivity when stored for 72 days at 4 C. Either agitation of stored coliphage suspensions held at 31 C or wide fluctuations in storage temperature produced an increased loss of infectivity. In the airborne state, freshly prepared coliphage and stored coliphage behaved similarly, with survival diminishing as the relative humidity (RH) was lowered. The greatest loss occurred during the first five min following aerosolization. The results showed that only under certain conditions of temperature and relative humidity can T3 coliphage be used as a satisfactory aerosol tracer.  相似文献   

3.
Iron (Fe) deposition from African dust has been implicated in a variety of environmental impacts on downwind terrestrial and marine ecosystems throughout the Caribbean. The most abundant form of Fe in African dust is FeIII, which is often not bioavailable. The objective of this study was to determine to what degree microorganisms isolated from African dust collected in Trinidad and Tobago are capable of producing siderophores that mobilize bioavailable Fe into the environment. Aerosol samples were collected for microbial analyses during African dust conditions in the source region (Mali) and downwind sites (Trinidad and Tobago). Microbial community fingerprints, obtained by means of terminal restriction fragment length polymorphism analysis, were compared among aerosol samples and possible Trinidadian sources of locally aerosolized microorganisms (sea water and soils). Ordination of the fingerprint data revealed similarities between aerosols from the source region and the aerosols and soils of downwind regions. Aerosol isolates from the downwind sites were screened for siderophore production using a modified chrome azurol-S (CAS) assay. Twenty-five percent of isolates tested that were sampled under non-dust conditions and 65% of African dust isolates produced at least one type of siderophore; among African dust isolates, all known classes of siderophores were produced. These data support African dust microorganism siderophore production as a viable mechanism by which Fe bioavailability may be increased in downwind locations, given appropriate conditions for microbial proliferation.  相似文献   

4.
The objective of this study was to determine the feasibility of using airborne T3 coliphage as a viral tracer in microbial aerosols. Although T3 coliphage was relatively stable when stored either at temperatures ranging from 21 to 37 C or in the frozen state at -20 C, there was a 2-log loss in infectivity when stored for 72 days at 4 C. Either agitation of stored coliphage suspensions held at 31 C or wide fluctuations in storage temperature produced an increased loss of infectivity. In the airborne state, freshly prepared coliphage and stored coliphage behaved similarly, with survival diminishing as the relative humidity (RH) was lowered. The greatest loss occurred during the first five min following aerosolization. The results showed that only under certain conditions of temperature and relative humidity can T3 coliphage be used as a satisfactory aerosol tracer.  相似文献   

5.
The relative chlorine sensitivities of bacteria isolated from chlorinated and unchlorinated drinking water distribution systems were compared by two independent methods. One method measured the toxic effect of free chlorine on bacteria, whereas the other measured the effect of combined chlorine. Bacteria from the chlorinated system were more resistant to both the combined and free forms of chlorine than those from the unchlorinated system, suggesting that there may be selection for more chlorine-tolerant microorganisms in chlorinated waters. Bacteria retained on the surfaces of 2.0-microns Nuclepore membrane filters were significantly more resistant to free chlorine compared to the total microbial population recovered on 0.2-micron membrane filters, presumably because aggregated cells or bacteria attached to suspended particulate matter exhibit more resistance than unassociated microorganisms. In accordance with this hypothesis, scanning electron microscopy of suspended particulate matter from the water samples revealed the presence of attached bacteria. The most resistant microorganisms were able to survive a 2-min exposure to 10 mg of free chlorine per liter. These included gram-positive spore-forming bacilli, actinomycetes, and some micrococci. The most sensitive bacteria were readily killed by chlorine concentrations of 1.0 mg liter-1 or less, and included most gram-positive micrococci, Corynebacterium/Arthrobacter, Klebsiella, Pseudomonas/Alcaligenes, Flavobacterium/Moraxella, and Acinetobacter.  相似文献   

6.
Using three sampler devices (SAS, Andersen Six-Stages and All Glass Impinger), the environmental impact of bacterial and fungal aerosols generated by municipal wastewater treatment plants operating with different methods of sludge oxygenation were evaluated. The highest microbial concentrations were recovered above the tanks (2247 cfu m-3) and in downwind positions (1425 cfu m-3), where a linear correlation (P < 0.05) was found between the quantity of sewage treated and the entities of microbial aerosol dispersion. Moreover, an exponential increase (P < 0.05) in the bacteria recovered from the air occurred at increasing times of treatment. However, after long-term plant operation, high bacterial and fungal concentrations were found in almost all of the sites around the plant. Coliforms, enterococci, Escherichia coli and staphylococci were almost always recovered in downwind positions. Considerable fractions (20-40%) of sampled bacteria were able to penetrate the final stages of the Andersen apparatus and thus, are likely to be able to penetrate the lungs. The plant operating with a fine bubble diffused air system instead was found to generate rather low concentrations of bacteria and fungi; moreover, staphylococci and indicator micro-organisms were almost absent. Finally, salmonellae, Shigella, Pseudomonas aeruginosa and Aeromonas spp. were not detected in either of the plants. The results indicate a remarkable dispersion of airborne bacteria and fungi from tanks in which oxygen is supplied via a mechanical agitation of sludge, and suggest the need to convert them to diffused aeration systems which pose a lesser hazard for human health.  相似文献   

7.
Bacterial isolates from an unchlorinated potable groundwater system and a chlorinated surface water system were screened by an agar overlay method for the ability to produce bacteriocin-like substances (BLS) inhibitory to the growth of Escherichia coli, Klebsiella sp., and Enterobacter aerogenes. The production of coliform-specific BLS by noncoliform bacteria varied with the site and date of isolation as well as the genus of the producer strain. A total of 448 bacterial isolates were screened from the chlorinated system, and 22.1% produced BLS specific for at least one of the three coliforms. In the unchlorinated system, 7.9% (n = 696) possessed this ability. Flavobacterium/Moraxella comprised 57.1% of all bacteria (from both systems) producing BLS. The possibility that BLS interfere with coliform detection in standard bacteriological water quality tests is discussed.  相似文献   

8.
Bacteria- and virus-containing aerosols were studied during the late summer and fall seasons in a midwestern suburb of the United States before and during the start-up and operation of an unenclosed activated sludge wastewater treatment plant. The study showed that the air in this suburban area contained low-level densities of indicator microorganisms. After the plant began operating, the densities of total aerobic bacteria-containing particles, standard plate count bacteria, total coliforms, fecal coliforms, fecal streptococci, and coliphages increased significantly in the air within the perimeter of the plant. Before plant operations, bacteria were detected from five genera, Klebsiella, Enterobacter, Serratia, Salmonella, and Aeromonas. During plant operations, the number of genera identified increased to 11. In addition to those genera found before plant operations, Escherichia, Providencia, Citrobacter, Acinetobacter, Pasteurella, and Proteus, were also identified. Enteric viruses were detected in low densities from the air emissions of this plant. Only standard plate count bacteria remained at significantly higher than base-line densities beyond 250 m downwind from the center of the aeration tanks. Fecal streptococci and coliphages appeared to be more stable in aerosols than the other indicator microorganisms studied. In general, the densities of microorganism-containing aerosols were higher at night than during the day. The techniques used in this study may be employed to establish microorganism-containing aerosol exposure during epidemiological investigations.  相似文献   

9.
Bacteria- and virus-containing aerosols were studied during the late summer and fall seasons in a midwestern suburb of the United States before and during the start-up and operation of an unenclosed activated sludge wastewater treatment plant. The study showed that the air in this suburban area contained low-level densities of indicator microorganisms. After the plant began operating, the densities of total aerobic bacteria-containing particles, standard plate count bacteria, total coliforms, fecal coliforms, fecal streptococci, and coliphages increased significantly in the air within the perimeter of the plant. Before plant operations, bacteria were detected from five genera, Klebsiella, Enterobacter, Serratia, Salmonella, and Aeromonas. During plant operations, the number of genera identified increased to 11. In addition to those genera found before plant operations, Escherichia, Providencia, Citrobacter, Acinetobacter, Pasteurella, and Proteus, were also identified. Enteric viruses were detected in low densities from the air emissions of this plant. Only standard plate count bacteria remained at significantly higher than base-line densities beyond 250 m downwind from the center of the aeration tanks. Fecal streptococci and coliphages appeared to be more stable in aerosols than the other indicator microorganisms studied. In general, the densities of microorganism-containing aerosols were higher at night than during the day. The techniques used in this study may be employed to establish microorganism-containing aerosol exposure during epidemiological investigations.  相似文献   

10.
Experiments were conducted to determine the effects of storage temperatures, relative humidity, and additives on the survival of aerosolized Escherichia coli phage T-3. The aerosol stability of the coliphage, calculated as per cent recovery, was not affected by storage at 10 or -70 C for up to 4 months. However, an increase in aerosol decay rate of coliphage stored at 10 C was observed. The effect of humidities ranging from 20 to 90% relative humidity was studied, and it was observed that humidities lower than 70% relative humidity significantly reduce the survival of airborne coliphage. The effect of various compounds on the aerosol decay rate of T-3 coliphage was studied at 50 and 85% relative humidity. Addition of dextrose in 0.1 M concentrations to the disseminating fluid significantly reduced aerosol decay rate at 50% relative humidity without affecting the decay at 85%. Addition of spermine, spermidine-phosphate, thiourea, galacturonic acid, and glucosaminic acid, individually or in combination, had no effect on aerosol decay rates. The use of deuterium oxide as the suspending fluid for dissemination had no effect on aerosol stability of the coliphage.  相似文献   

11.
DNA-based microbial source tracking (MST) methods were developed and used to specifically and sensitively track the unintended aerosolization of land-applied, anaerobically digested sewage sludge (biosolids) during high-wind events. Culture and phylogenetic analyses of bulk biosolids provided a basis for the development of three different MST methods. They included (i) culture- and 16S rRNA gene-based identification of Clostridium bifermentans, (ii) direct PCR amplification and sequencing of the 16S rRNA gene for an uncultured bacterium of the class Chloroflexi that is commonly present in anaerobically digested biosolids, and (iii) direct PCR amplification of a 16S rRNA gene of the phylum Euryarchaeota coupled with terminal restriction fragment length polymorphism to distinguish terminal fragments that are unique to biosolid-specific microorganisms. Each method was first validated with a broad group of bulk biosolids and soil samples to confirm the target's exclusive presence in biosolids and absence in soils. Positive responses were observed in 100% of bulk biosolid samples and in less than 11% of the bulk soils tested. Next, a sampling campaign was conducted in which all three methods were applied to aerosol samples taken upwind and downwind of fields that had recently been land applied with biosolids. When average wind speeds were greater than 5 m/s, source tracking results confirmed the presence of biosolids in 56% of the downwind samples versus 3% of the upwind samples. During these high-wind events, the biosolid concentration in downwind aerosols was between 0.1 and 2 microg/m3. The application of DNA-based source tracking to aerosol samples has confirmed that wind is a possible mechanism for the aerosolization and off-site transport of land-applied biosolids.  相似文献   

12.
生物气溶胶中微生物的种类复杂多样,其采集和鉴定是全面掌握微生物气溶胶生物特性的关键,对防控气溶胶病原体传播十分重要.本文简要综述了微生物气溶胶的生物特性和潜在危害性,介绍了微生物气溶胶的一般采集方法,采集器采集生物气溶胶的基本原理、特点和优缺点.将有助于研究人员根据实验目的在采集低浓度生物气溶胶时选择合适的采样器.本文...  相似文献   

13.
Reuse of partially treated domestic wastewater for agricultural irrigation is a growing practice in arid regions throughout the world. A field sampling campaign to determine bioaerosol concentration, culturability, and identity at various wind speeds was conducted at a flooded wastewater irrigation site in Mexicali, Baja California, Mexico. Direct fluorescent microscopy measurements for total microorganisms, culture-based assays for heterotrophs and gram-negative enteric bacteria, and small-subunit rRNA gene-based cloning were used for microbial characterizations of aerosols and effluent wastewater samples. Bioaerosol results were divided into two wind speed regimens: (i) below 1.9 m/s, average speed 0.5 m/s, and (ii) above 1.9 m/s, average speed 4.5 m/s. Average air-borne concentration of total microorganisms, culturable heterotrophs, and gram-negative enteric bacteria were, respectively, 1.1, 4.2, and 6.2 orders of magnitude greater during the high-wind-speed regimen. Small-subunit rRNA gene clone libraries processed from samples from air and the irrigation effluent wastewater during a high-wind sampling event indicate that the majority of air clone sequences were more than 98% similar to clone sequences retrieved from the effluent wastewater sample. Overall results indicate that wind is a potential aerosolization mechanism of viable wastewater microorganisms at flood irrigation sites.  相似文献   

14.
Reuse of partially treated domestic wastewater for agricultural irrigation is a growing practice in arid regions throughout the world. A field sampling campaign to determine bioaerosol concentration, culturability, and identity at various wind speeds was conducted at a flooded wastewater irrigation site in Mexicali, Baja California, Mexico. Direct fluorescent microscopy measurements for total microorganisms, culture-based assays for heterotrophs and gram-negative enteric bacteria, and small-subunit rRNA gene-based cloning were used for microbial characterizations of aerosols and effluent wastewater samples. Bioaerosol results were divided into two wind speed regimens: (i) below 1.9 m/s, average speed 0.5 m/s, and (ii) above 1.9 m/s, average speed 4.5 m/s. Average air-borne concentration of total microorganisms, culturable heterotrophs, and gram-negative enteric bacteria were, respectively, 1.1, 4.2, and 6.2 orders of magnitude greater during the high-wind-speed regimen. Small-subunit rRNA gene clone libraries processed from samples from air and the irrigation effluent wastewater during a high-wind sampling event indicate that the majority of air clone sequences were more than 98% similar to clone sequences retrieved from the effluent wastewater sample. Overall results indicate that wind is a potential aerosolization mechanism of viable wastewater microorganisms at flood irrigation sites.  相似文献   

15.
Bacteriological analyses were performed on the effluent from a conventional water treatment pilot plant in which granular activated carbon (GAC) had been used as the final process to assess the impact of GAC on the microbial quality of the water produced. Samples were collected twice weekly for 160 days from the effluents of six GAC columns, each of which used one of four different empty-bed contact times (7.5, 15, 30, and 60 min). The samples were analyzed for heterotrophic plate counts and total coliforms. Effluent samples were also exposed to chloramines and free chlorine for 60 min (pH 8.2, 23 degrees C). Bacterial identifications were performed on the disinfected and nondisinfected effluents. Additional studies were conducted to assess the bacteriological activity associated with released GAC particles. The results indicated that heterotrophic plate counts in the effluents from all columns increased to 10(5) CFU/ml within 5 days and subsequently stabilized at 10(4) CFU/ml. The heterotrophic plate counts did not differ at different empty-bed contact times. Coliforms (identified as Enterobacter spp.) were recovered from the nondisinfected effluent on only two occasions. The disinfection results indicated that 1.5 mg of chloramines per liter inactivated approximately 50% more bacteria than did 1.0 mg of free chlorine per liter after 1 h of contact time. Chloramines and chlorine selected for the development of different bacterial species--Pseudomonas spp. and Flavobacterium spp., respectively.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

16.
Modification of M-FC medium by eliminating rosolic acid.   总被引:11,自引:10,他引:1       下载免费PDF全文
Eliminating rosolic acid from M-FC medium improves the MFC procedure by allowing higher fecal coliform colony recoveries with greater ease in counting. Samples of unchlorinated and chlorinated domestic sewage, creek, lake, and river water were analyzed for fecal coliforms by standard procedures. Results of 200 comparisons of fecal coliform counts on M-FC medium without and with rosolic acid showed that higher counts were obtained 71% of the time when rosolic acid was excluded without an overgrowth of background colonies. Results from analyzing chlorinated sewage showed that eliminating rosolic acid improved the recovery of fecal coliform bacteria by 49%. A total of 1,675 blue colonies and 766 nonblue colonies were verified. Of the 1,675 blue colonies, 1,566 were confirmed as fecal coliform bacteria, for a verification of 93.5%. The percent verification of nonblue colonies as noncoliform bacteria was 84.2% (644/766).  相似文献   

17.
Bacteriological analyses were performed on the effluent from a conventional water treatment pilot plant in which granular activated carbon (GAC) had been used as the final process to assess the impact of GAC on the microbial quality of the water produced. Samples were collected twice weekly for 160 days from the effluents of six GAC columns, each of which used one of four different empty-bed contact times (7.5, 15, 30, and 60 min). The samples were analyzed for heterotrophic plate counts and total coliforms. Effluent samples were also exposed to chloramines and free chlorine for 60 min (pH 8.2, 23 degrees C). Bacterial identifications were performed on the disinfected and nondisinfected effluents. Additional studies were conducted to assess the bacteriological activity associated with released GAC particles. The results indicated that heterotrophic plate counts in the effluents from all columns increased to 10(5) CFU/ml within 5 days and subsequently stabilized at 10(4) CFU/ml. The heterotrophic plate counts did not differ at different empty-bed contact times. Coliforms (identified as Enterobacter spp.) were recovered from the nondisinfected effluent on only two occasions. The disinfection results indicated that 1.5 mg of chloramines per liter inactivated approximately 50% more bacteria than did 1.0 mg of free chlorine per liter after 1 h of contact time. Chloramines and chlorine selected for the development of different bacterial species--Pseudomonas spp. and Flavobacterium spp., respectively.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

18.
Eliminating rosolic acid from M-FC medium improves the MFC procedure by allowing higher fecal coliform colony recoveries with greater ease in counting. Samples of unchlorinated and chlorinated domestic sewage, creek, lake, and river water were analyzed for fecal coliforms by standard procedures. Results of 200 comparisons of fecal coliform counts on M-FC medium without and with rosolic acid showed that higher counts were obtained 71% of the time when rosolic acid was excluded without an overgrowth of background colonies. Results from analyzing chlorinated sewage showed that eliminating rosolic acid improved the recovery of fecal coliform bacteria by 49%. A total of 1,675 blue colonies and 766 nonblue colonies were verified. Of the 1,675 blue colonies, 1,566 were confirmed as fecal coliform bacteria, for a verification of 93.5%. The percent verification of nonblue colonies as noncoliform bacteria was 84.2% (644/766).  相似文献   

19.
A single-step most-probable-number method for enumerating fecal coliforms in sewage treatment plant effluents is described. The method requires the use of only one lactose-based medium and a single incubation temperature of 44.5 degrees C, and it can be completed in 18 h or less, as compared with up to 72 h for the standard most-probable-number method. The appearance of growth is the sole criterion used for designating positives, which can be determined either by increases in the electrical impedance ratio of inoculated medium, as compared to an uninoculated control using a Bactometer model 32, or by visual examination of inoculated medium for turbidity. In trials with 53 samples of unchlorinated sewage treatment plant effluent, fecal coliform counts by the single-step most-probable-number method, throughout a range of less than 10 to almost 10(7) fecal coliforms per 100 ml of effluent, were in excellent agreement with counts abtained by the standard most-probable-number procedure. Similar agreement was obtained in comparative trials with 31 chlorinated effluent samples from two sewage treatment plants. Overall, 87% of 452 positives were confirmed as containing fecal coliforms. The applicability of the single-step most-probable-number method to automated sewage treatment plant operations is discussed.  相似文献   

20.
A single-step most-probable-number method for enumerating fecal coliforms in sewage treatment plant effluents is described. The method requires the use of only one lactose-based medium and a single incubation temperature of 44.5 degrees C, and it can be completed in 18 h or less, as compared with up to 72 h for the standard most-probable-number method. The appearance of growth is the sole criterion used for designating positives, which can be determined either by increases in the electrical impedance ratio of inoculated medium, as compared to an uninoculated control using a Bactometer model 32, or by visual examination of inoculated medium for turbidity. In trials with 53 samples of unchlorinated sewage treatment plant effluent, fecal coliform counts by the single-step most-probable-number method, throughout a range of less than 10 to almost 10(7) fecal coliforms per 100 ml of effluent, were in excellent agreement with counts abtained by the standard most-probable-number procedure. Similar agreement was obtained in comparative trials with 31 chlorinated effluent samples from two sewage treatment plants. Overall, 87% of 452 positives were confirmed as containing fecal coliforms. The applicability of the single-step most-probable-number method to automated sewage treatment plant operations is discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号