首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple, sensitive and reproducible method was developed for the determination of lamotrigine in whole blood with on-line solid phase extraction followed by HPLC separation with UV detection. Whole blood samples were diluted 1:1 with water and then injected directly on a clean-up column dry-packed with 40microm C8 silica and separated on a C18 reversed-phase column (150x4.6mm) at room temperature. The extraction column was activated with methanol and conditioned with phosphate buffer of pH 4.5. Mobile phases consisted of phosphate buffer of pH 4.5 for the extraction column and of phosphate buffer of pH 4.5 - acetonitrile (60:40, v/v) for the analytical column. At a flow rate of 1.0ml/min and a connection time of 1.0min, the complete cycle time was 10.0min. Detection was carried out at 260nm. No internal standard was necessary. The method was linear over concentration range 0.2-20.0microg/ml for lamotrigine. Recovery was 98%. Within-day and between-day coefficients of variation ranged from 1.8 to 6.7%.  相似文献   

2.
A simple, rapid, precise and accurate isocratic reversed-phase stability-indicating HPLC method was developed and validated for the simultaneous determination of atorvastatin (AT) and amlodipine (AM) in commercial tablets. The method has shown adequate separation for AM, AT from their associated main impurities and their degradation products. Separation was achieved on a Perfectsil Target ODS-3, 5 microm, 250 mm x 4.6 mm i.d. column using a mobile phase consisting of acetonitrile-0.025 M NaH(2)PO(4) buffer (pH 4.5) (55:45, v/v) at a flow rate of 1 ml/min and UV detection at 237 nm. The drugs were subjected to oxidation, hydrolysis, photolysis and heat to apply stress conditions. The linearity of the proposed method was investigated in the range of 2-30 microg/ml (r=0.9994) for AT and 1-20 microg/ml (r=0.9993) for AM. The limits of detection were 0.65 microg/ml and 0.35 microg/ml for AT and AM, respectively. The limits of quantitation were 2 microg/ml and 1 microg/ml for AT and AM, respectively. Degradation products produced as a result of stress studies did not interfere with the detection of AT and AM and the assay can thus be considered stability-indicating.  相似文献   

3.
The chiral separation of norgestrel enantiomers using reversed-phase high-performance liquid chromatography (RP-HPLC) was studied with hydroxypropyl-beta-cyclodextrin (HP-beta-CD) as chiral mobile phase additive. The effect of mobile phase composition, concentration of HP-beta-CD and column temperature on enantioselective separation were investigated. The quantification properties of the developed RP-HPLC method were examined. A baseline separation of norgestrel enantiomers was achieved on a Agilent ZORBAX Eclipse XDB-C8 column (150 mm x 4.6 mm i.d., 5 microm). The mobile phase was a mixture of acetonitrile and phosphate buffer (pH 5.0, 20 mM) containing 25 mM HP-beta-CD (30:70, v/v) with a flow rate of 1.0 ml/min. The UV detector was set at 240 nm. Calibration curves were linear (n=8) in the range of 0.2-25 microg/ml, the limit of detection and quantitation were 0.10 and 0.20 microg/ml, respectively, for racemic norgestrel. The values of RSD of repeatability and intermediate precision for spiked sample were less than 4.8%. The method was successfully applied to the enantioselective determination of this drug in stereoselective skin permeation study.  相似文献   

4.
A validated high-performance liquid chromatography method is described for the determination of scutellarin in rat plasma using a liquid-liquid extraction and ultraviolet (UV) absorbance detection. The separation used a Diamonsil ODS column (250 mm x 4.6mm i.d., 5 microm particle size) with an isocratic mobile phase consisting of methanol-acetonitrile-50mM dihydrogen ammonium phosphate buffer (22:15:63 (v/v/v), adjusted to pH 2.5 with 1M phosphoric acid). The ultraviolet detector operated at 335 nm. Plasma samples were extracted with ethyl acetate after acidification. The extraction recovery of scutellarin ranged from 68.1 to 80.5%. High selectivity and a low quantitation limit (0.050 microg/ml) were achieved. The linear range was 0.050-12.5 microg/ml, correlation coefficient r=0.9981. The method has a good reproducibility, R.S.D. values were below 7.9% for within-day and between-day precision. The method is simple, rapid, and applicable to preliminary pharmacokinetic studies of scutellarin in rats.  相似文献   

5.
A rapid and simple high-performance liquid chromatographic (HPLC) method has been developed and validated for determination of scopoletin in rat plasma using psoralen as internal standard. Chromatographic separation was achieved on a C(18) column using methanol and distilled water (49:51, v/v) containing 0.05% (v/v) phosphoric acid as mobile phase. The UV detector was set at 345 nm. The calibration curve was linear over the range of 0.165-9.90 microg/ml with a correlation coefficient of 0.9994. The recovery for plasma samples of 0.165, 1.32 and 6.60 microg/ml was 93.2%, 95.9% and 95.5%, respectively. The RSD of intra- and inter-day assay variations was less than 6.7%. This HPLC assay is a precise and reliable method for the analysis of scopoletin in pharmacokinetic studies.  相似文献   

6.
A rapid, sensitive and simple high-performance liquid chromatographic (HPLC) method with ultraviolet detector (UV) has been developed for the determination of bifendate in 100 microl plasma of rats. Sample preparation was carried out by deproteinization with 100 microl of acetonitrile. A 20 microl of supernatant was directly injected into the HPLC system with methanol-double distilled water (65/35, v/v) as the mobile phase at a flow rate of 1.0 ml/min. Separation was performed with a microBondapak C(18) column at 30 degrees C. The peak was detected at 278 nm. The calibration curve was linear (r(2)=0.9989) in the concentration range of 0.028-2.80 microg/ml in plasma. The intra- and inter-day variation coefficients were not more than 6.55% and 6.07%, respectively. The limit of detection was 5 ng/ml. The mean recoveries of bifendate were ranged from 94.53% to 99.36% in plasma. The present method has been successfully applied to the pharmacokinetic study of bifendate liposome in rats.  相似文献   

7.
20 (R,S)-Ginsenoside-Rg2, an anti-shock agent, is prescribed as a racemate. To analyze simultaneously the enantiomers of 20 (R)-ginsenoside-Rg2 and 20 (S)-ginsenoside-Rg2 in plasma, a simple and reproducible high-performance liquid chromatographic (HPLC) method has been developed. The enantiomeric separation and determination were successfully achieved using a Diamonsil ODS C18 reversed-phase column (5 microm, 250 mm x 4.6 mm) with an RP18 (5 microm) guard column and a mobile phase of MeOH-aq. 4% H3PO4 (65:35, v/v, pH 5.1) with UV detection at 203 nm. Both enantiomers, 20 (R)-ginsenoside-Rg2 and 20 (S)-ginsenoside-Rg2, were well separated at 14.5 min and 13.6 min, respectively. The linear ranges of the standard curves were 2.0-250 microg/ml. The intra- and inter-day precision (R.S.D.) were 相似文献   

8.
A simple and rapid capillary zone electrophoresis determination method with UV detection of grepafloxacin and clinafloxacin has been developed. The separation was performed in 35 mM borate-35 mM phosphate buffer solution (pH 8.6), containing 6% (v/v) of acetonitrile. Analyses were realised using fused-silica capillaries (57 cm length x 75 microm I.D.) and the operating conditions were: 15 kV applied voltage, 30 degrees C and detection at 279 nm. Piromidic acid was used as an internal standard. The linear concentration range of application was 1.0-120.0 microg ml(-1) for both compounds, with a detection limit of 0.2 microg ml(-1) for grepafloxacin and 0.3 microg ml(-1) for clinafloxacin. The analysis yielded good reproducibility (RSD between 3.37 and 1.74%). It was applied to the determination of grepafloxacin and clinafloxacin in human and rat urine samples. The method was validated using HPLC as a reference method. Recovery levels were between 94.5 and 103%.  相似文献   

9.
The development and validation of a direct injection high-performance liquid chromatographic (HPLC) method, with column switching, for the determination of metyrapol enantiomers and metyrapone in human plasma is described. The system used in this work was composed of a restricted access media (RAM) bovine serum albumin (BSA) octyl column coupled to an amylose tris(3,5-dimethoxyphenylcarbamate) chiral column. Water was used as eluent for the first 5 min at a flow rate of 1.0 ml/min for the elution of the plasma proteins and then acetonitrile-water (30:70 v/v) for the transfer and analysis of metyrapol enantiomers and metyrapone, which were detected by UV at lambda = 260 nm. The total analysis time was about 32 min. The calibration curves for each enantiomer and for the metyrapone were linear in the ranges 0.075-0.75 microg/ml and 0.150-1.50 microg/ml, respectively. Recoveries, intra- and interday precision and accuracy were determined using three quality controls, one low (0.18 microg/ml), one medium (0.75 microg/ml), and one high (1.35 microg/ml) plasma concentration. Quantitative recoveries and good precision and accuracy were obtained. The limit of quantitation were 0.045 microg/ml for both enantiomers and for the metyrapone.  相似文献   

10.
A simple and sensitive HPLC method has been developed and validated for the determination of oridonin (ORI) in rabbit plasma. A simple liquid-liquid extraction (LLE) method was applied to extract ORI and the internal standard (IS), isopsoralen, from rabbit plasma. Chromatographic separation of ORI and the IS was achieved with a Kromasil C18 5-mum column (250 mm x 4.6 mm) using methanol-water (50:50, v/v) as mobile phase at a flow rate of 1 mL/min. The ultraviolet (UV) detection wavelength was set at 241 nm. The lower limit of quantification (LLOQ) was 0.02 microg/mL. The calibration curves were linear over a concentration range of 0.02-10 microg/mL. The assay accuracy and precision were within the range of 95.1-113.5% and 5.4-8.6%, respectively. This HPLC method was applied successfully to the pharmacokinetic study of ORI-loaded poly(caprolactone)-poly(ethylene oxide)-poly(caprolactone) copolymer nanoparticles (ORI-PCL-PEO-PCL-NP) in rabbits, given as a single intravenous injection at the dose equivalent to 2mg of ORI/kg, and the pharmacokinetic parameters for ORI were compared with a single intravenous injection of a ORI solution at the same dose.  相似文献   

11.
In order to discriminate selegiline (SG) use from methamphetamine (MA) use, the urinary metabolites of SG users have been investigated using high-performance liquid chromatography (HPLC)–electrospray ionization mass spectrometry (HPLC–ESI–MS). Selegiline-N-oxide (SGO), a specific metabolite of SG, was for the first time detected in the urine, in addition to other metabolites MA, amphetamine (AP) and desmethylselegiline (DM-SG). A combination of a Sep-pak C18 cartridge for the solid-phase extraction, a semi-micro SCX column (1.5 mm I.D.×150 mm) for HPLC separation and ESI–MS for detection provided a simple and sensitive procedure for the simultaneous determination of these analytes. Acetonitrile–10 mM ammonium formate buffer adjusted to pH 3.0 (70:30, v/v) at a flow-rate of 0.1 ml/min was found to be the most effective mobile phase. Linear calibration curves were obtained over the concentration range from 0.5 to 100 ng/ml for all the analytes by monitoring each protonated molecular ion in the selected ion monitoring (SIM) mode. The detection limits ranged from 0.1 to 0.5 ng/ml. Upon applying the scan mode, 10–20 ng/ml were the detection limits. Quantitative investigation utilizing this revealed that SGO was about three times more abundant (47 ng/ml, 79 ng/ml) than DM-SG in two SG users’ urine samples tested here. This newly-detected, specific metabolite SGO was found to be an effective indicator for SG administration.  相似文献   

12.
13.
A simple high-performance liquid chromatographic (HPLC) method was developed for the simultaneous determination of iohexol, iothalamate, p-aminohippuric acid (PAH) and n-acetyl-p-aminohippuric acid (n-acetyl-PAH) in human plasma and urine. A C(18) column at a flow rate of 1 ml/min with an aqueous mobile phase of trifluoroacetic acid (0.1% TFA in deionized water (pH 2.2), v/v) and methanol gradient was used for component separation. The plasma and urine assay demonstrated linearity from 10 to 50 microg/ml for iohexol and iothalamate, 5 to 40 microg/ml for PAH and 2.5 to 40 microg/ml for n-acetyl-PAH. The HPLC plasma and urine results obtained for PAH were used to calculate the subject kidney effective renal plasma flow (ERPF) and the iohexol results were used to calculate the subject kidney glomerular filtration rate (GFR). The HPLC results for PAH were then compared to an alternative colorimetric method for analyzing PAH to determine if subject metabolism (acetylation) of PAH affected the ERPF results obtained using the colorimetric method, the subsequent ERPF/GFR ratio and clinical impression of subject patient kidney function. The method was utilized in several different clinical studies evaluating the effect of kidney function from medications (phase IV evaluations) marketed for patients with cardiovascular disease.  相似文献   

14.
New bioanalytical SPE-HPLC-PDA-FL method for the determination of the neuroleptic drug tiapride and its N-desethyl metabolite was developed, validated and applied to xenobiochemical and pharmacokinetic studies in humans and animals. The sample preparation process involved solid-phase extraction of diluted plasma spiked with sulpiride (an internal standard) using SPE cartridges DSC-PH Supelco, USA. Chromatographic separation of the extracts was performed on a Discovery HS F5 250 mm × 4 mm (Supelco) column containing pentafluorophenylpropylsilyl silica gel. Mobile phase (acetonitrile-0.01 M phosphate buffer pH=3, flow rate 1 ml min(-1)) in the gradient mode was employed in the HPLC analysis. Tandem UV photodiode-array→fluorescence detection was used for the determination of the analytes. Low concentrations of tiapride and N-desethyl tiapride were determined using a more selective fluorescence detector (λ(exc.)/λ(emiss.)=232 nm/334 nm), high concentrations (500-6000 pmol ml(-1)) using a UV PDA detector at 212 nm with a linear response. Each HPLC run lasted 15 min. Lower limits of quantification (LLOQ) for tiapride (N-desethyl tiapride) were found to be 8.24 pmol ml(-1) (10.11 pmol ml(-1)). The recoveries of tiapride ranged from 89.3 to 94.3%, 81.7 to 86.8% for internal standard sulpiride and 90.9 to 91.8% for N-desethyl tiapride.  相似文献   

15.
Mitoguazone is an antiproliferative agent used in chemotherapy. This study describes a simple and sensitive high-performance liquid chromatographic method for the determination of mitoguazone in 100 microl of plasma. Samples were deproteinized with 100 microl of a solution of internal standard (amiloride, 10 microg/ml) in acetonitrile. An aliquot of the supernatant was injected onto the column. HPLC separation was achieved on a silica column with the mobile phase of methanol-50 mM potassium phosphate buffer (pH 3)-triethylamine (80:20:0.3, v/v), at a flow-rate of 1 ml/min. The eluent was detected at 320 nm. The retention time was about 5.5 min for amiloride and 12 min for mitoguazone. No endogenous substances were found to interfere. Calibration curves were linear from 0.25 to 50 microg/ml. The absolute recoveries of mitoguazone and amiloride were both greater than 84%. The limit of quantitation was 0.25 microg/ml. The intra- and inter-day precision (expressed as RSD) was 5.8%, or less, and the accuracy was 94.7% of the nominal concentration. The method is suitable in pharmacokinetic investigation and monitoring mitoguazone concentration.  相似文献   

16.
N-acetyl-1-(p-chlorophenyl)-6,7-dimethoxy-1,2,3,4-tetrahydroisoquinoline derivative (PS3Ac) has been determined in brain tissues by high performance liquid chromatography (HPLC) coupled with a diode array detection. In a previous paper we presented a validation method for detecting PS3Ac and its metabolites in plasma samples after intraperitoneal administration to Wistar rats. In the present paper, we report the results of the determination of PS3Ac and its N-deacetyl (PS3) and O-demethyl (PS3OH) metabolites, in the brain after extraction based on a polymeric matrix with a high hydrophilic-lipophilic balance, using Oasis cartridges. The chromatographic separation was performed in an octadecylsilica stationary phase at 25 degrees C using a mixture of 10 mM potassium dihydrogen orthophosphate (pH 2.24) and acetonitrile in ratio of 30:70 (v/v) as mobile phase, with a flow rate of 0.8 ml/min. The method exhibited a large linear range from 0.05 to 2 microg/ml for all studied compounds (n=6). In the within-day assay (n=4), the accuracy ranged from 87.5% determined with 0.05 microg/ml of PS3 to 110.1% determined with 0.2 microg/ml of PS3OH. In the between-day assay the coefficient of variation ranged from 2.4 determined with 0.05 microg/ml of PS3 to 9.7 determined with 0.2 microg/ml of PS3OH. The extraction efficiency ranged from 77.8% for PS3OH at 0.2 microg/ml to 94.3 for PS3Ac at 0.5 microg/ml. The limit of detection for all the tetrahydroisoquinoline derivatives ranged around 50 ng/ml. The method proved to be highly sensitive and specific to determinate PS3Ac and its metabolites and has been successfully applied to value their concentrations in brain matrix over the time.  相似文献   

17.
The method of high-performance liquid chromatography (HPLC) with UV-vis detection was used and validated for the simultaneous determination of six flavonoids (puerarin, rutin, morin, luteolin, quercetin, kaempferol) and troxerutin in rat urine and chicken plasma. Chromatographic separation was performed using a VP-ODS column (150 mm x 4.6 mm, 5.0 microm) maintained at 35.0 degrees C. The mobile phase was a mixture of water, methanol and acetic acid (57:43:1, v/v/v, pH 3.0) at the flow rate of 0.8 mL/min. Six flavonoids and troxerutin were analyzed simultaneously with good separation. On optimum conditions, calibration curves were found to be linear with the ranges of 0.10-70.00 microg/mL (puerarin, rutin, morin, luteolin, quercetin, kaempferol) and 0.50-350.00 microg/mL (troxerutin). The detection limits were 0.010-0.050 microg/mL. The method was validated for accuracy and precision, and it was successfully applied to determine drug concentrations in rat urine and chicken plasma samples from rat and chicken that had been orally administered with six flavonoids and troxerutin.  相似文献   

18.
A method based on a liquid-liquid extraction procedure followed by high-performance liquid chromatography (HPLC) coupled with UV-visible detection is described and validated for the determination of lauroyl-indapamide in rat whole blood. The blood sample was extracted with diethyl ether after the addition of 10% trifluoroacetic acid (aq.). The chromatographic separation was performed on a Chromasil ODS column, using methanol-acetonitrile-tetrahydrofuran-0.2% trifluoroacetic acid (170:20:15:38, v/v/v/v) as the mobile phase. The UV detection wavelength was set at 240 nm. The extraction recovery of lauroyl-indapamide was ranged from 76.5 to 82.6%, and the calibration curve had a good linearity in the range of 0.048-200 microg/ml (r = 0.9976). The method presents appropriate intra-day and inter-days repeatabilities, showing values below 7.4% in terms of the percentage of relative standard deviation (R.S.D.). The method proposed is simple, rapid and sensitive, being useful for pharmacokinetic studies in rats.  相似文献   

19.
A liquid chromatographic-tandem mass spectrometric method (LC-MS/MS) for the determination of ulifloxacin, the active metabolite of prulifloxacin, in human plasma is described. After sample preparation by protein precipitation with methanol, ulifloxacin and ofloxacin (internal standard) were chromatographically separated on a C(18) column using a mobile phase consisting of methanol, water and formic acid (70:30:0.2, v/v/v) at a flow rate of 0.5 ml/min and then were detected using MS/MS by monitoring their precursor-to-product ion transitions, m/z 350-->m/z 248 for ulifloxacin and m/z 362-->m/z 261 for ofloxacin, in selected reaction monitoring (SRM) mode. Positive electrospray ionization was used for the ionization process. The linear range was 0.025-5.0 microg/ml for ulifloxacin with a lower limit of quantitation of 0.025 microg/ml. Within- and between-run precision was less than 6.6 and 7.8%, respectively, and accuracy was within 2.0%. The recovery ranged from 92.1 to 98.2% at the concentrations of 0.025, 0.50 and 5.0 microg/ml. Compared with the reported LC method, the present LC-MS/MS method can directly determine the ulifloxacin in human plasma without any need of derivatization. The present method has been successfully used for the pharmacokinetic studies of a prulifloxacin formulation product after oral administration to healthy volunteers.  相似文献   

20.
The development and validation of a high-performance liquid chromatographic and UV detection method was accomplished for quantitative determination of levamisole in chicken tissues, eggs and plasma. The chromatographic separation was achieved on Luna 5 microm C(18) column using a mobile phase of 0.2% acetic acid in water:methanol (50:50 (v/v)) and Pic B-7 low UV reagent and the pH was adjusted to 7.31 with ammonium hydroxide and UV wavelength was 225 nm. Limits of quantification were 0.025 microg/g for all tissues and 0.003 microg/ml for plasma. Limit of detection was 0.001 microg/g for tissues and plasma.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏