1.
We describe a semi-homogenous (SH) implementation of a fluidic force discrimination (FFD) assay using only two reagent mixtures and three assay steps that can be performed in as little as 10min. Previously microbead labels and FFD have been combined to achieve multiplexed, femtomolar nucleic acid hybridization and immunoassays in a microarray format [Mulvaney, S.P., Cole, C.L., Kniller, M.D., Malito, M., Tamanaha, C.R., Rife, J.C., Stanton, M.W., Whitman, L.J., 2007. Biosen. Bioelectron. 23, 191-200.]. In SH FFD assays, the microbeads and any required intermediate receptors (e.g., secondary antibodies) are first mixed directly with a sample, allowing target analytes to be efficiently captured onto the beads. The target-loaded beads are then specifically captured onto a microarray surface, with nonspecifically bound beads removed by controlled, laminar fluidic forces. The remaining beads on each microarray capture spot are counted to determine the targets' identities and concentrations. SH target collection provides a 1000-fold improvement in the assay sensitivity, down to attomolar concentrations, as demonstrated by our detection of staphylococcal enterotoxin B (SEB) at 35 aM (1 fg/ml). We also show that SH assays are adaptable for extraction, preconcentration, and identification of analytes in complex sample matrices, including assays for SEB and ricin toxoid in serum and whole blood. Finally, we present a detailed model of the reaction kinetics that reveals how capturing the targets onto the beads in solution provides a significant kinetic advantage at low target concentrations where mass transport to a microarray surface is most limited.  相似文献   

2.
The efficiency of hybridization analysis with oligonucleotide microarrays depends heavily on the method of detection. Conventional methods based on labeling nucleic acids with fluorescent, chemiluminescent, enzyme, or radioactive reporters suffer from a number of serious drawbacks which demand development of new detection techniques. Here, we report two new approaches for detection of hybridization with oligonucleotide microarrays employing magnetic beads as active labels. In the first method streptavidin-coated magnetic beads are used to discover biotin-labeled DNA molecules hybridized with arrayed oligonucleotide probes. In the second method biotin-labeled DNA molecules are bound first to the surface of magnetic beads and then hybridized with arrayed complementary strands on bead-array contacts. Using a simple low-power microscope with a dark-field illumination and a pair of complementary primers as a model hybridization system we evaluated sensitivity, speed, and cost of the new detection method and compared its performance with the detection techniques employing enzyme and fluorescent labels. It was shown that the detection of microarray-hybridized DNA with magnetic beads combines low cost with high speed and enhanced assay sensitivity, opening a new way to routine hybridization assays which do not require precise measurements of DNA concentration.  相似文献   

3.
A sensitive and selective genomagnetic assay for the electrochemical detection of food pathogens based on in situ DNA amplification with magnetic primers has been designed. The performance of the genomagnetic assay was firstly demonstrated for a DNA synthetic target by its double-hybridization with both a digoxigenin probe and a biotinylated capture probe, and further binding to streptavidin-modified magnetic beads. The DNA sandwiched target bound on the magnetic beads is then separated by using a magneto electrode based on graphite-epoxy composite. The electrochemical detection is finally achieved by an enzyme marker, anti-digoxigenin horseradish peroxidase (HRP). The novel strategy was used for the rapid and sensitive detection of polymerase chain reaction (PCR) amplified samples. Promising resultants were also achieved for the DNA amplification directly performed on magnetic beads by using a novel magnetic primer, i.e., the up PCR primer bound to magnetic beads. Moreover, the magneto DNA biosensing assay was able to detect changes at single nucleotide polymorphism (SNP) level, when stringent hybridization conditions were used. The reliability of the assay was tested for Salmonella spp., the most important pathogen affecting food safety.  相似文献   

4.
In electrochemical DNA hybridization assays target or probe DNAs end-labeled with electroactive compounds have been frequently used. We show that multiple osmium labels yielding faradaic (at carbon or mercury electrodes) and catalytic signals (at mercury electrodes) can be easily covalently bound to DNA molecules. We use (GAA)(7) (T)(n) oligodeoxynucleotides (ODNs) with n ranging between 5 and 50. (T)(n) tails are selectively modified with osmium tetroxide,2,2'-bipyridine leaving the (GAA)(7) repeat intact for the DNA hybridization. These ODNs are applied as reporter probes (RP's) in DNA hybridization double-surface (DS) assay using magnetic beads for the DNA hybridization and pyrolytic graphite (PGE) or hanging mercury drop (HMDE) electrodes for the electrochemical detection. We show that in difference to the usual single-surface methods (where the RP has to be bound to target DNA near to the surface to communicate with the electrode) in the DS assay the RP can be bound to DNA regardless of its position and can used for the determination of the length of DNA repetitive sequences. Several fmols or about a hundred of amol of a RP with osmium-labeled (T)(50) tail can be detected at PGE and HMDE, respectively, at 1-2 min accumulation time.  相似文献   

5.
Systematic evolution of ligands by exponential enrichment (SELEX) was used to develop DNA ligands (aptamers) to cholera whole toxin and staphylococcal enterotoxin B (SEB). Affinity selection of aptamers was accomplished by conjugating the biotoxins to tosyl-activated magnetic beads. The use of magnetic beads reduces the volumes needed to perform aptamer selection, thus obviating alcohol precipitation and allowing direct PCR amplification from the bead surface. Following five rounds of SELEX, 5'-biotinylated aptamers were bound to streptavidin-coated magnetic beads and used for the detection of ruthenium trisbypyridine [Ru(bpy)3(2+)]-labeled cholera toxin and SEB by an electrochemiluminescence methodology. A comparison of control (double-stranded) aptamer binding was made with aptamers that were heat denatured at 96 degrees C (single-stranded) and allowed to cool (conform) in the presence of biotoxin-conjugated magnetic beads. Results suggest that control aptamers performed equally well when compared to heat-denatured DNA aptamers in the cholera toxin electrochemiluminescence assay and a colorimetric microplate assay employing peroxidase-labeled cholera toxin and 5'-amino terminated aptamers conjugated to N-oxysuccinimide-activated microtiter wells. Interestingly, however, in the SEB electrochemiluminescence assay, double-stranded aptamers exceeded the performance of single-stranded aptamers. The detection limits of all aptamer assays were in the low nanogram to low picogram ranges.  相似文献   

6.
We describe the use of two heparin-binding proteins, avidin and lactoferrin, as probes for monitoring the amount of heparin immobilized to plastic surfaces. The proteins were derivatized with either fluorescent labels or europium chelates, enabling sensitive, fast, reproducible, and robust assays, and were used to measure the amount of protein bound to heparinized microplates, with particular attention to plates that have been coated with bovine serum albumin (BSA)-heparin conjugate. This direct method unequivocally shows that BSA-heparin affords an economical, convenient, and reliable method for coating both polystyrene microtiter plates and magnetic beads with heparin. We demonstrate that assays using directly labeled proteins overcome the problems of dissociation of the heparin-protein complex, which can occur during incubation and washing steps associated with antibody-based detection methods, and the loss in binding capacity caused by certain blocking regimes. We suggest that labeled avidin and lactoferrin are convenient probes for heparinized surfaces with the potential for much wider applicability than that presented here.  相似文献   

7.
Different assay formats based on the coupling of magnetic beads with electrochemical transduction were compared here for the detection of thrombin by using a thrombin specific aptamer. By using the thrombin-binding aptamer, a direct and an indirect competitive assay for thrombin have been developed by immobilising the aptamer or the protein, respectively. Moreover, another strategy was based on the direct measurement of the enzymatic product of thrombin captured by the immobilised aptamer. All the assays were developed by coupling the electrochemical transduction with the innovative and advantageous use of magnetic beads.

The assays based on the immobilisation of the protein were not successful since no binding was recorded between thrombin and its aptamer. With the direct competitive assay, when the aptamer was immobilised onto the magnetic beads, a detection limit of 430 nM for thrombin was achieved. A lower detection limit for the protein (175 nM) was instead obtained by detecting the product of the enzymatic reaction catalysed by thrombin. All these assays were finally compared with a sandwich assay which reached a detection limit of 0.45 nM of thrombin demonstrating the best analytical performances.

With this comparison the importance of a deep study on the different analytical approaches for thrombin detection to reach the performances of the best assay configuration has been demonstrated.  相似文献   


8.
Two gold nanoparticles-based genomagnetic sensors designs for detection of DNA hybridization are described. Both assays are based on a magnetically induced direct electrochemical detection of gold tags on magnetic graphite-epoxy composite electrodes. The first design is a two strands assay format that consists of the hybridization between a capture DNA strand which is linked with paramagnetic beads and another DNA strand related to BRCA1 breast cancer gene used as a target which is coupled with streptavidin-gold nanoparticles. The second genomagnetic sensor design is a sandwich assay format with more application possibilities. A cystic fibrosis related DNA strand is used as a target and sandwiched between two complementary DNA probes: the first one linked with paramagnetic beads and a second one modified with gold nanoparticles via biotin-streptavidin complexation reactions. The electrochemical detection of gold nanoparticles by differential pulse voltammetry was performed in both cases. The developed genomagnetic sensors provide a reliable discrimination against noncomplementary DNA as well against one and three-base mismatches. Optimization parameters affecting the hybridization and analytical performance of the developed genosensors are shown for genomagnetic assays of DNA sequences related with the breast cancer and cystic fibrosis genes.  相似文献   

9.
10.
High sensitivity immunoassays using particulate fluorescent labels.   总被引:7,自引:0,他引:7  
The use of polystyrene fluorescent microspheres as sensitive labels in direct-detection (not enzymatically amplified) heterogeneous equilibrium "sandwich" immunoassays in 96-well plates is described. With mouse IgG as a model antigen, a fluorescent particulate label is more sensitive than a corresponding soluble reporter. The limit of detection of mouse IgG in the multiparametrically optimized assay was 0.2 ng/ml (7.6 x 10(8) antigens/ml) for the particulate reporter and 50 ng/ml (1.9 x 10(11) antigens/ml) for the soluble reporter. The sensitivities of assays using the particulate label were dependent on the surface densities of the capture and reporter antibodies and the concentration of reporter beads. Sensitivity was improved by adding the preformed reporter antibody/fluorescent microsphere complex to trapped antigen on the well surfaces instead of sequentially adding the reporter antibody and then the fluorescent microspheres. Maximal (equilibrium) binding of the particulate reporter to captured antigen occurred after 20 h with a concentration of 1.4 x 10(9) reporter beads/ml. Thus, particulate fluorescent labels provide high sensitivity in direct-detection immunoassays.  相似文献   

11.
A novel magnetic bead-based protein kinase assay was developed using MALDI-TOF mass spectrometry (MALDI-TOF MS) and immunochemifluorescence as two independent detection techniques. Abltide substrate was immobilized onto magnetic beads via noncovalent biotin–streptavidin interactions. This noncovalent immobilization strategy facilitated peptide release and allowed MALDI-TOF MS analysis of substrate phosphorylation. The use of magnetic beads provided rapid sample handling and allowed secondary analysis by immunochemifluorescence to determine the degree of substrate phosphorylation. This dual detection technique was used to evaluate the inhibition of c-Abl kinase by imatinib and dasatinib. For each inhibitor, IC50 (half-maximal inhibitory concentration) values determined by these two different detection methods were consistent and close to values reported in the literature. The high-throughput potential of this new approach to kinase assays was preliminarily demonstrated by screening a chemical library consisting of 31 compounds against c-Abl kinase using a 96-well plate. In this proof-of-principle experiment, both MALDI-TOF MS and immunochemifluorescence were able to compare inhibitor potencies with consistent values. Dual detection may significantly enhance the reliability of chemical library screening and identify false positives and negatives. Formatted for 96-well plates and with high-throughput potential, this dual detection kinase assay may provide a rapid, reliable, and inexpensive route to the discovery of small-molecule drug leads.  相似文献   

12.
Two homogeneous proximity assays for tyrosine kinases, scintillation proximity assay (SPA) and homogeneous time-resolved fluorescence (HTRF), have been developed and compared. In both formats, the kinase assay was performed using biotinylated peptide substrate, ATP ([33P]ATP in the case of SPA), and tyrosine kinase in a 96-well assay format. After the kinase reaction was stopped, streptavidin-coated SPA beads or europium cryptate-labeled anti-phosphotyrosine antibody and streptavidin-labeled allophycocyanin were added as detection reagents for SPA or HTRF assays, respectively. Since the assay signal was detected only when the energy donor (radioactivity for SPA, Eu for HTRF) and the energy acceptor molecules (SPA beads for SPA, allophycocyanin for HTRF) were in close proximity, both assays required no wash or liquid transfer steps. This homogeneous ("mix-and-measure") nature allows these assays to be much simpler, more robust, and easier to automate than traditional protein kinase assays, such as a filter binding assay or ELISA. Both assays have been miniaturized to a 384-well format to reduce the assay volume, thereby saving the valuable screening samples as well as assay reagents, and automated using automated pipetting stations to increase the assay throughput. Several advantages and disadvantages for each assay are described.  相似文献   

13.
This study reports the development of an on-chip enzyme-mediated primer extension process based on a microfluidic device with microbeads array for single-nucleotide discrimination using quantum dots as labels. The functionalized microbeads were independently introduced into the arrayed chambers using the loading chip slab. A single channel was used to generate weir structures to confine the microbeads and make the beads array accessible by microfluidics. The applied allele-specific primer extension method employed a nucleotide-degrading enzyme (apyrase) to achieve specific single-nucleotide detection. Based on the apyrase-mediated allele-specific primer extension with quantum dots as labels, on-chip single-nucleotide discrimination was demonstrated with high discrimination specificity and sensitivity (0.5 pM, signal/noise > 3) using synthesized target DNA. The chip-based signal enhancement for single-nucleotide discrimination resulted in 200 times higher sensitivity than that of an off-chip test. This microfluidic device successfully achieved simultaneous detection of two disease-associated single-nucleotide polymorphism sites using polymerase chain reaction products as target. This apyrase-mediated microfluidic primer extension approach combines the rapid binding kinetics of homogeneous assays of suspended microbeads array, the liquid handling capability of microfluidics, and the fluorescence detection sensitivity of quantum dots to provide a platform for single-base analysis with small reagent consumption, short assay time, and parallel detection.  相似文献   

14.
Electrochemical magneto immunosensing of antibiotic residues in milk   总被引:1,自引:0,他引:1  
A novel electrochemical immunosensing strategy for the detection of sulfonamide antibiotics in milk based on magnetic beads is presented. Among the different strategies for immobilizing the class-specific anti-sulfonamide antibody to the magnetic beads--such as those based on the use of Protein A or carboxylate modified magnetic beads - ,the best strategy was found to be the covalent bonding on tosyl-activated magnetic beads. The immunological reaction for the detection of sulfonamide antibiotics performed on the magnetic bead is based on a direct competitive assay using a tracer with HRP peroxidase for the enzymatic labelling. After the immunochemical reactions, the modified magnetic beads can be easily captured by a magneto sensor made of graphite-epoxy composite (m-GEC), which is also used as the transducer for the electrochemical immunosensing. The electrochemical detection is thus achieved through a suitable substrate for the enzyme HRP and an electrochemical mediator. The electrochemical approach is also compared with a novel magneto-ELISA with optical detection. The performance of the electrochemical immunosensing strategy based on magnetic beads was successfully evaluated using spiked milk samples, and the detection limit was found to be 1.44 microg L(-1) (5.92 nmol L(-1)) for raw full cream milk. This strategy offers great promise for rapid, simple, cost-effective and on-site analysis of biological, food and environmental samples.  相似文献   

15.
Microarray technology has brought a paradigmatic change in bioanalytics. However, highly sensitive and accurate assays are still needed for a real breakthrough. We present a simple and generic approach for fluorescent signal amplification with fluorescent microparticle labels. The assay principle was demonstrated using a reverse array model consisting of spots of bovine serum albumin with a small fraction of the proteins biotinylated. Specific binding of streptavidin coated fluorescent microparticles to the spots was promoted by applying a controlled continuous microparticle flow. The surface bound beads were visualized and quantified with confocal microscopy images. Comparison with standard fluorescent and flow discrimination assays has revealed several advantages of our approach. First, non-specific particle binding could be reduced to less than 1 particle/spot making therefore the visualization of single biomolecular bonds possible. Second, the amplification scheme presented here is generic and can be applied to any fluorescent microarray. Furthermore, this assay makes use of a biotin-streptavidin linkage and can therefore be applied to all kind of assays. Finally, single fluorescent microbeads can be easily visualized with standard optical equipments, so that no high performance equipment is required.  相似文献   

16.
In this report two nonradioactive assays for quantitative analysis of polymerase chain reaction (PCR) products are presented. In the first assay, magnetic beads coated with streptavidin were used to capture biotinylated PCR fragments. After hybridization with a hapten-labeled probe, these beads were analyzed either by flow cytometry (method A) or by immunoenzymatic reactions (method B). Using a dilution series of purified PCR products, we consistently found a lower detection limit of 1.5 fmol for method A than the 0.15-fmol limit for method B. In the second assay we used the peroxidase-based enhanced chemiluminescence system in combination with a cooled charge-coupled device camera to quantify PCR fragments that were spotted on membranes. A linear logarithmic response was observed between the amount of light produced within a certain time interval and the number of DNA molecules. With an exposure time of 5 min, a detection limit of 0.15 fmol was found. Longer exposure times did not result in a higher sensitivity. We conclude that the assays are of sufficient sensitivity for application in quantitative PCR strategies. The nonradioactive technology facilitates implementation of these assays in routine settings.  相似文献   

17.
Sensitive and specific electrochemiluminescence (ECL) assays were used to detect Clostridium botulinum neurotoxins serotypes A, B, E, and F in undiluted human serum, undiluted human urine, assay buffer, and selected food matrices (whole milk, apple juice, ground beef, pastry, and raw eggs). These novel assays used paramagnetic bead-based electrochemiluminescent technology in which biotinylated serotype-specific antibodies were bound to streptavidin-coated paramagnetic beads. The beads acted as the solid support and captured analyte from solution. Electrochemiluminescent detection relied on the use of ruthenium chelate-labeled anti-serotype antibodies and analysis with a BioVeris M-Series M1R analyzer. The sensitivities of the assays in clinically relevant matrices were 50 pg/ml for serotypes A and E, 100 pg/ml for serotype B, and 400 pg/ml for serotype F. The detection limits in selected food matrices ranged from 50 pg/ml for serotype A to 50 to 100 pg/ml for serotypes B, E, and F. The antibodies used for capture and detection exhibited no cross-reactivity when tested with the other serotypes. When purified native toxin was compared with toxins complexed to neurotoxin-associated proteins, no significant differences in assay response were noted for serotypes A, B, and F. Interestingly, the native form of serotype E exhibited reduced signal and limit of detection compared with the complexed form of the protein. We suspect that this difference may be due to trypsin activation of this particular serotype. The assays described in this article demonstrate limits of detection similar in range to the gold standard mouse bioassay, but with greatly reduced time to data. These rapid sensitive assays may have potential use in clinical settings, research studies, and screening of food products for botulinum toxins.  相似文献   

18.
A compact biosensor platform with giant magneto-resistive (GMR) sensors suited for the detection of superparamagnetic nanoparticle labels is presented. The platform consist of disposable biosensor cartridges and an electronic reader, which enables quantitative detection with high analytical performance, combined with robustness, ease of use and at low cost. In order to optimise the signal-to-noise ratio (SNR), magnetic labels are excited at high frequency. Wires, integrated in the silicon of the sensor chip are used to generate a well-defined magnetic field on the sensor surface, thus removing the need for mechanical alignment with external apparatus. A signal modulation scheme is applied to obtain optimal detection accuracy. The platform is scalable and can be adapted according to application-specific requirements. Experimental results indicate that three beads of 300 nm diameter can be detected on a sensor surface of 1500 microm2 for a measurement time of 1s.  相似文献   

19.
Among the plethora of affinity biosensor systems based on biomolecular recognition and labeling assays, magnetic labeling and detection is emerging as a promising new approach. Magnetic labels can be non-invasively detected by a wide range of methods, are physically and chemically stable, relatively inexpensive to produce, and can be easily made biocompatible. Here we provide an overview of the various approaches developed for magnetic labeling and detection as applied to biosensing. We illustrate the challenges to integrating one such approach into a complete sensing system with a more detailed discussion of the compact Bead Array Sensor System developed at the U.S. Naval Research Laboratory, the first system to use magnetic labels and microchip-based detection.  相似文献   

20.
We report on a new and simple one-reagent method for general protein assay. It makes use of one of two new reactive labeling reagents presented here (and referred to as pyrylium [Py] labels). These can be applied for both photometric and fluorometric protein assays at near neutral pHs at room temperature. The Py labels undergo a large spectral change on conjugation to the amino group of proteins and typically change their color from blue to red. Therefore, and unlike in other assays, there is no need to separate the unconjugated (blue) label from the red conjugate, which can be determined by direct photometry with a limit of detection of 1.2 microg/ml for human serum albumin. The assay can be extended to fluorometry because the fluorescence of the free Py label is weak (with a quantum yield of <1%) but increases strongly (to >40%) on conjugation. The strong fluorescence of the red conjugates can be determined directly and without interference by the blue (and weakly fluorescent) free label. The fluorometric assay resulted in a limit of detection of 60 ng/ml for bovine serum albumin (BSA). Validation of the fluorescence assay of blood plasma samples spiked with BSA gave recoveries in the range from 91 to 103%.  相似文献   