首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The height of the medial longitudinal arch (MLA) is thought to be a predisposing factor to various lower extremity injuries. Discrepancy exists as to whether MLA height plays a role in injury prevention. The purpose of this study was to determine the intertester and intratester reliability, and the validity of the mirrored foot photo box (MFPB) and caliper measurements to radiographic measurements. METHODS: Thirty subjects with equal numbers of men and women were recruited. Both feet were tested (n=60) in a 90% weight bearing stance. A set of anatomic landmarks were palpated, marked, and measured using a caliper, MFPB, and radiographs. The protocol was completed by two testers on 2 days approximately 1 week apart. Intertester and intratester reliability were determined using the intraclass correlation coefficient (ICC)(2,k) and the ICC(2,1), respectively. Validity of both measurement techniques to radiographic measurements was determined using the ICC(2,k). RESULTS: The intertester reliability ranged from 0.991 to 0.577, while the intratester reliability ranged from 0.994 to 0.527, with first metatarsal angle being the only variable with poor reliability. Most variables demonstrated acceptable validity between the MFPB and the caliper measurements, and acceptable validity between the MFPB and calipers compared to radiographic measurements. The MFPB took 51.3+/-19.6s per foot while the caliper measurements averaged 227.4+/-68.9s to complete the measurements. DISCUSSION: The MFPB is as reliable as the caliper measurements, and offers better intertester reliability. Both the caliper and MFPB measurements demonstrated acceptable validity to radiographic measurements and testing time was reduced when using the MFPB compared to calipers.  相似文献   

2.
The purpose of this study was to determine if segmental skeletal length contributes to vertical jump (VJ) displacement in recreational athletes. Skeletal length measurements of the trunk, femur, tibia, and foot were obtained by palpation of bony landmarks and a standard tape measure. A pilot study (n = 10) examined the intratester and intertester reliability for each skeletal measure. The pilot investigation revealed fair to excellent intratester and intertester reliability. Seventy-eight recreational athletes (55 men and 23 women) with a mean age of 21.9 +/- 2.9 years participated in the investigation. Multiple regression analysis with gender as a categorical indicator variable revealed a significant gender difference; therefore, men and women were analyzed separately. Regression analysis for men identified foot length (p < 0.033, R(2) = 0.08) as the only significant skeletal length predictor of VJ displacement. None of the skeletal length measures was predictive of VJ displacement in women. Based on the results of this investigation, intrinsic skeletal length is not a strong predictor of VJ displacement in young adult recreational athletes.  相似文献   

3.
The misalignment between recorded in-focus and out-of-focus images using the Phase Diversity (PD) algorithm leads to a dramatic decline in wavefront detection accuracy and image recovery quality for segmented active optics systems. This paper demonstrates the theoretical relationship between the image misalignment and tip-tilt terms in Zernike polynomials of the wavefront phase for the first time, and an efficient two-step alignment correction algorithm is proposed to eliminate these misalignment effects. This algorithm processes a spatial 2-D cross-correlation of the misaligned images, revising the offset to 1 or 2 pixels and narrowing the search range for alignment. Then, it eliminates the need for subpixel fine alignment to achieve adaptive correction by adding additional tip-tilt terms to the Optical Transfer Function (OTF) of the out-of-focus channel. The experimental results demonstrate the feasibility and validity of the proposed correction algorithm to improve the measurement accuracy during the co-phasing of segmented mirrors. With this alignment correction, the reconstructed wavefront is more accurate, and the recovered image is of higher quality.  相似文献   

4.
The dual Euler angles method has been proposed as an alternative approach to describe the general spatial human joint motion. In this study, the dual Euler angles method was applied to study the three-dimensional motion of the ankle complex. The methodology for obtaining dual Euler angles of the ankle complex was developed by using a "Flock of Birds" electromagnetic tracking device. The repeatability of the methodology was studied based on the intertester and intratester variability analysis. Finally kinematic coupling characteristics of the ankle complex during dorsiflexion-plantarflexion, eversion-inversion, and abduction-adduction were analyzed according to the parameters of the dual Euler angles.  相似文献   

5.
The purpose of this study was to determine the intratester reliability of surface electromyography (EMG) assessment of the gluteus medius muscle in healthy people and people with chronic nonspecific low back pain (CNLBP) during barefoot walking. Gluteus medius muscle activity was measured twice in 40 people without and 30 people with CNLBP approximately 7 days apart. Walking gluteus medius muscle activity was normalised to maximal voluntary isometric contractions during side-lying hip abduction with manual resistance. Good intratester reliability (ICC > 0.75) was found for mean, peak, and peak to peak amplitude for healthy people. Only mean amplitude demonstrated good intratester reliability in those with CNLBP. Peak amplitude and peak to peak amplitude of the gluteus medius muscle of those with CNLBP, and the time of peak amplitude in both groups, demonstrated moderate reliability (ICC ranged from 0.50 to 0.58). Moderate to large standard error of measurement and minimal detectable change values were reported for outcome measurements. These results suggest that potentially large levels of random error can occur between sessions. Future research can build on this study for those with pathology and attempt to establish change values for EMG that are clinically meaningful.  相似文献   

6.
An electromagnetic position tracking device was evaluated to determine its static and dynamic accuracy and reliability for applications related to measuring in vivo joint kinematics. The device detected the position and orientation of small coiled sensors, maintained in an electromagnetic field. System output was measured against known translations or rotations throughout the measurement volume. Average translational errors during static testing were 0.1 +/- 0.04, 0.2 +/- 0.17, and 0.8 +/- 0.81 mm (mean+/-SD) for sensors 50, 300, and 550 mm away from the field generator, respectively. Average rotational errors were 0.4 +/- 0.31 degrees, 0.4 +/- 0.21 degrees, and 0.9 +/- 0.85 degrees (mean +/- SD) for sensors located at the same distances. Since we intended to use this system in an animal walking on a treadmill, we incrementally moved the sensors under various treadmill conditions. The effects of treadmill operation on translational accuracy were found to be negligible. The effects of dynamic motions on sensor-to-sensor distance were also assessed for future data collection in the animal. Sensor-to-sensor distance showed standard deviations of 2.6 mm and a range of 13 mm for the highest frequency tested (0.23 Hz). We conclude that this system is useful for static or slow dynamic motions, but is of limited use for obtaining gait kinematics at higher speeds.  相似文献   

7.
In this paper we propose constructing an improved two-level neural network to predict protein secondary structure. Firstly, we code the whole protein composition information as the inputs to the first-level network besides the evolutionary information. Secondly, we calculate the reliability score for each residue position based on the output of the first-level network, and the role of the second-level network is to take full advantage of the residues with a higher reliability score to impact the neighboring residues with a lower one for improving the whole prediction accuracy. Thirdly, considering it is indeed a problem that the target protein can be lost in the multiple sequence alignment we propose to code single sequence into the second-level network. The experimental results show that our proposed method can efficiently improve the prediction accuracy.  相似文献   

8.
The purpose of this study was to determine intrarater reliability of the 1 repetition maximum (1RM) estimation for shoulder internal rotation. The accuracy of the estimated 1RM was determined by establishing the actual 1RM. Fifteen subjects were positioned supine with the shoulder in 0 degrees abduction (position 1) and prone with the shoulder in 90 degrees abduction (position 2). Subjects were placed in both testing positions and performed resisted shoulder internal rotation. A 1RM estimation equation was used to estimate shoulder internal rotation strength. After 1 week, procedures were repeated and intrarater reliability was calculated. One week after 1RM estimation procedures were completed, the accuracy of an estimated 1RM was determined by establishing an actual 1RM. The results indicated excellent intrarater reliability for position 1 (intraclass correlation coefficient [ICC] = 0.99) and position 2 (ICC = 0.96). The correlation coefficients for accuracy indicated excellent concurrent validation was attained for position 1 (ICC = 0.99) and position 2 (ICC = 0.97). Shoulder internal rotation 1RM estimation appears to be reliable and accurate. Clinicians may use submaximal loads to estimate the 1RM and decrease the possibility of injury during actual 1RM strength testing.  相似文献   

9.
ABSTRACT: BACKGROUND: Vertebral rotation found in structural scoliosis contributes to trunkal asymmetry which is commonly measured with a simple Scoliometer device on a patient's thorax in the forward flexed position. The new generation of mobile 'smartphones' have an integrated accelerometer, making accurate angle measurement possible, which provides a potentially useful clinical tool for assessing rib hump deformity. This study aimed to compare rib hump angle measurements performed using a Smartphone and traditional Scoliometer on a set of plaster torsos representing the range of torsional deformities seen in clinical practice. METHODS: Nine observers measured the rib hump found on eight plaster torsos moulded from scoliosis patients with both a Scoliometer and an Apple iPhone on separate occasions. Each observer repeated the measurements at least a week after the original measurements, and were blinded to previous results. Intra-observer reliability and inter-observer reliability were analysed using the method of Bland and Altman and 95% confidence intervals were calculated. The Intra-Class Correlation Coefficients (ICC) were calculated for repeated measurements of each of the eight plaster torso moulds by the nine observers. RESULTS: Mean absolute difference between pairs of iPhone/Scoliometer measurements was 2.1 degrees, with a small (1 degrees) bias toward higher rib hump angles with the iPhone. 95% confidence intervals for intra-observer variability were +/- 1.8 degrees (Scoliometer) and +/- 3.2 degrees (iPhone). 95% confidence intervals for inter-observer variability were +/- 4.9 degrees (iPhone) and +/- 3.8 degrees (Scoliometer). The measurement errors and confidence intervals found were similar to or better than the range of previously published thoracic rib hump measurement studies. CONCLUSIONS: The iPhone is a clinically equivalent rib hump measurement tool to the Scoliometer in spinal deformity patients. The novel use of plaster torsos as rib hump models avoids the variables of patient fatigue and discomfort, inconsistent positioning and deformity progression using human subjects in a single or multiple measurement sessions.  相似文献   

10.
Screw displacement axes (SDAs) have been employed to describe joint kinematics in biomechanical studies. Previous reports have investigated the accuracy of SDAs combining various motion analysis techniques and smoothing procedures. To our knowledge, no study has assessed SDA accuracy describing the relative movement between adjacent bodies with an electromagnetic tracking system. This is important, since in relative motion, neither body is fixed and consequently sensitivity to potential measurement errors from both bodies may be significant. Therefore, this study assessed the accuracy of SDAs for describing relative motion between two moving bodies. We analyzed numerical simulated data, and physical experimental data recorded using a precision jig and electromagnetic tracking device. The numerical simulations demonstrated SDA position accuracy (p=0.04) was superior for single compared to relative body motion, whereas orientation accuracy (p=0.2) was similar. Experimental data showed data-filtering (Butterworth filter) improved SDA position and orientation accuracies for rotation magnitudes smaller or equal to 5.0 degrees, with no effect at larger rotation magnitudes (p<0.05). This suggests that in absence of a filter, SDAs should only be calculated at rotations of greater than 5.0 degrees. For rotation magnitudes of 0.5 degrees (5.0 degrees ) about the SDA, SDA position and orientation error measurements determined from filtered experimental data were 3.75+/-0.30 mm (3.31+/-0.21 mm), and 1.10+/-0.04 degrees (1.04+/-0.03 degrees ), respectively. Experimental accuracy values describing the translation along and rotation about the SDA, were 0.06+/-0.00 mm and 0.09+/-0.01 degrees, respectively. These small errors establish the capability of SDAs to detect small translations, and rotations. In conclusion, application of SDAs should be a useful tool for describing relative motion in joint kinematic studies.  相似文献   

11.
Lin HN  Notredame C  Chang JM  Sung TY  Hsu WL 《PloS one》2011,6(12):e27872
Most sequence alignment tools can successfully align protein sequences with higher levels of sequence identity. The accuracy of corresponding structure alignment, however, decreases rapidly when considering distantly related sequences (<20% identity). In this range of identity, alignments optimized so as to maximize sequence similarity are often inaccurate from a structural point of view. Over the last two decades, most multiple protein aligners have been optimized for their capacity to reproduce structure-based alignments while using sequence information. Methods currently available differ essentially in the similarity measurement between aligned residues using substitution matrices, Fourier transform, sophisticated profile-profile functions, or consistency-based approaches, more recently.In this paper, we present a flexible similarity measure for residue pairs to improve the quality of protein sequence alignment. Our approach, called SymAlign, relies on the identification of conserved words found across a sizeable fraction of the considered dataset, and supported by evolutionary analysis. These words are then used to define a position specific substitution matrix that better reflects the biological significance of local similarity. The experiment results show that the SymAlign scoring scheme can be incorporated within T-Coffee to improve sequence alignment accuracy. We also demonstrate that SymAlign is less sensitive to the presence of structurally non-similar proteins. In the analysis of the relationship between sequence identity and structure similarity, SymAlign can better differentiate structurally similar proteins from non- similar proteins. We show that protein sequence alignments can be significantly improved using a similarity estimation based on weighted n-grams. In our analysis of the alignments thus produced, sequence conservation becomes a better indicator of structural similarity. SymAlign also provides alignment visualization that can display sub-optimal alignments on dot-matrices. The visualization makes it easy to identify well-supported alternative alignments that may not have been identified by dynamic programming. SymAlign is available at http://bio-cluster.iis.sinica.edu.tw/SymAlign/.  相似文献   

12.
MOTIVATION: Most multiple sequence alignment programs use heuristics that sometimes introduce errors into the alignment. The most commonly used methods to correct these errors use iterative techniques to maximize an objective function. We present here an alternative, knowledge-based approach that combines a number of recently developed methods into a two-step refinement process. The alignment is divided horizontally and vertically to form a 'lattice' in which well aligned regions can be differentiated. Alignment correction is then restricted to the less reliable regions, leading to a more reliable and efficient refinement strategy. RESULTS: The accuracy and reliability of RASCAL is demonstrated using: (i) alignments from the BAliBASE benchmark database, where significant improvements were often observed, with no deterioration of the existing high-quality regions, (ii) a large scale study involving 946 alignments from the ProDom protein domain database, where alignment quality was increased in 68% of the cases; and (iii) an automatic pipeline to obtain a high-quality alignment of 695 full-length nuclear receptor proteins, which took 11 min on a DEC Alpha 6100 computer Availability: RASCAL is available at ftp://ftp-igbmc.u-strasbg.fr/pub/RASCAL. SUPPLEMENTARY INFORMATION: http://bioinfo-igbmc.u-strasbourg.fr/BioInfo/RASCAL/paper/rascal_supp.html  相似文献   

13.
Magnetic resonance imaging (MRI) is a widely used method for non-invasive study of the structure and function of the human brain. Increasing magnetic field strengths enable higher resolution imaging; however, long scan times and high motion sensitivity mean that image quality is often limited by the involuntary motion of the subject. Prospective motion correction is a technique that addresses this problem by tracking head motion and continuously updating the imaging pulse sequence, locking the imaging volume position and orientation relative to the moving brain. The accuracy and precision of current MR-compatible tracking systems and navigator methods allows the quantification and correction of large-scale motion, but not the correction of very small involuntary movements in six degrees of freedom. In this work, we present an MR-compatible tracking system comprising a single camera and a single 15 mm marker that provides tracking precision in the order of 10 m and 0.01 degrees. We show preliminary results, which indicate that when used for prospective motion correction, the system enables improvement in image quality at both 3 T and 7 T, even in experienced and cooperative subjects trained to remain motionless during imaging. We also report direct observation and quantification of the mechanical ballistocardiogram (BCG) during simultaneous MR imaging. This is particularly apparent in the head-feet direction, with a peak-to-peak displacement of 140 m.  相似文献   

14.
This study was designed to examine the reliability and validity of the bioelectrical impedance method (BIA) of measuring body composition and compare its accuracy with the results obtained by standard anthropometric methods BIA, skinfold fat, and hydrostatically measured percent fat (% fat) were obtained on 44 women and 24 men. Each subject was tested four times by two testers on two different days. Generalizability theory was used to estimate reliability and measurement error that considered both day-to-day and intertester error. The BIA, skinfold fat, and hydrostatic methods were all found to be reliable (Rxx = 0.957-0.987) with standard errors ranging from 0.9 to 1.5% fat. An additional 26 men (n = 50) and 38 women (n = 82) were tested once and combined with the data used for the reliability analysis to cross-validate BIA estimates of % fat with hydrostatically determined % fat. The cross-validation correlations for the BIA determinations of % fat ranged from 0.71 to 0.76, which were significantly lower than that obtained with the sum of seven (sigma 7) skinfolds equations (rxy = 0.92 for men and 0.88 for women). The correlations between the weight-to-height ratio body mass index (BMI) and hydrostatically determined % fat were 0.75 and 0.74 for men and women, respectively. The standard errors of estimate for the two BIA models ranged from 4.6 to 6.4% fat compared with 2.6 and 3.6% fat for the sigma 7 equations. The BIA method for measuring body composition was comparable to the BMI method, with height and weight accounting for most of the variance in the BIA equation.  相似文献   

15.
The purpose of this study was to establish and cross-validate a method for analyzing gait patterns determined by the center of mass (COM) through inertial sensors embedded in smart devices. The method employed an extended Kalman filter in conjunction with a quaternion rotation matrix approach to transform accelerations from the object onto the global frame. Derived by double integration, peak-to-trough changes in vertical COM position captured by a motion capture system, inertial measurement unit, and smart device were compared in terms of averaged and individual steps. The inter-rater reliability and levels of agreement for systems were discerned through intraclass correlation coefficients (ICC) and Bland–Altman plots. ICCs corresponding to inter-rater reliability were good-to-excellent for position data (ICCs,.80–.95) and acceleration data (ICCs,.54–.81). Levels of agreements were moderate for position data (LOA, 3.1–19.3%) and poor for acceleration data (LOA, 6.8%–17.8%). The Bland–Altman plots, however, revealed a small systematic error, in which peak-to-trough changes in vertical COM position were underestimated by 2.2 mm; the Kalman filter?s accuracy requires further investigation to minimize this oversight. More importantly, however, the study?s preliminary results indicate that the smart device allows for reliable COM measurements, opening up a cost-effective, user-friendly, and popular solution for remotely monitoring movement. The long-term impact of the smart device method on patient rehabilitation and therapy cannot be underestimated: not only could healthcare expenditures be curbed (smart devices being more affordable than today‘s motion sensors), but a more refined grasp of individual functioning, activity, and participation within everyday life could be attained.  相似文献   

16.
The purposes of this investigation were to establish the reliability of selected physical performance tests in women athletes and nonathletes and to determine performance differences between groups. Fifty women (25 athletes, 25 nonathletes) performed 5 tests in 2 sessions. The performance tests included the figure-eight hop test, up-and-down hop test, side-to-side hop test, hexagon hop test, and zigzag run test. Intraclass correlation coefficients (ICC [2, 1]) were calculated for trial-to-trial, intertester, and day-to-day reliability. Independent t-tests with Bonferroni adjustment (alpha = 0.01) were used for each individual test to compare differences between groups. All tests showed good reliability values (ICC > or = 0.76) in the nonathlete group for all conditions and varied reliability values (0.48-0.99) among conditions in the athlete group. The independent t-tests showed a statistically significant group effect (t > or = 3.041; p < or = 0.004) for all tests. The results showed that these physical performance tests are reliable measurement tools in the female population.  相似文献   

17.
We have developed a laser-aligned measuring device to facilitate the measurement of linear hand dimensions. Our objective has been to make a simple, clinically applicable device for anthropometry of the hands in patients with arthritis in order to gauge the progression of hand deformities. The system provides an alternative to the use of rules, tapes, photogrammetry and least-squares devices which have previously been applied to hand measurements. The system delivers results which are not significantly different from those measured with rules and callipers and has a similar level of accuracy. The use of laser pointers for alignment facilitates measurements which necessitate picking the highest point of the hand. The device is portable and simple to use in the clinic. We have used it to measure hand dimensions in normal subjects and patients with arthritis. However, the system could equally well be used to facilitate measurement of other objects with an irregular surface profile.  相似文献   

18.
Wu M  Chatterji S  Eisen JA 《PloS one》2012,7(1):e30288
Uncertainty in multiple sequence alignments has a large impact on phylogenetic analyses. Little has been done to evaluate the quality of individual positions in protein sequence alignments, which directly impact the accuracy of phylogenetic trees. Here we describe ZORRO, a probabilistic masking program that accounts for alignment uncertainty by assigning confidence scores to each alignment position. Using the BALIBASE database and in simulation studies, we demonstrate that masking by ZORRO significantly reduces the alignment uncertainty and improves the tree accuracy.  相似文献   

19.
Pronation and supination have been shown to affect wrist goniometer measurement accuracy. The purpose of this study was to compare differences in measurement accuracy between a commonly used biaxial, single transducer wrist goniometer (System A) and a biaxial, two-transducer wrist goniometer (System B) over a wide range of pronation and supination (P/S) positions. Eight subjects moved their wrist between -40 and 40 degrees of flexion/extension (F/E) and -10 and 20 degrees of radial/ulnar (R/U) deviation in four different P/S positions: 90 degrees pronation; 45 degrees pronation; 0 degrees neutral and 45 degrees supination. System A was prone to more R/U crosstalk than System B and the amount of crosstalk was dependent on the P/S position. F/E crosstalk was present with both goniometer systems and was also shown to be dependent on P/S. When moving from pronation to supination, both systems experienced a similar extension offset error; however R/U offset errors were roughly equal in magnitude but opposite in direction. The calibration position will affect wrist angle measurements and the magnitude and direction of measurement errors. To minimize offset errors, the goniometer systems should be calibrated in the P/S posture most likely to be encountered during measurement. Differences in goniometer design and application accounted for the performance differences.  相似文献   

20.
Protein structure alignment methods are used for the detection of evolutionary and functionally related positions in proteins. A wide array of different methods are available, but the choice of the best method is often not apparent to the user. Several studies have assessed the alignment accuracy and consistency of structure alignment methods, but none of these explicitly considered membrane proteins, which are important targets for drug development and have distinct structural features. Here, we compared 13 widely used pairwise structural alignment methods on a test set of homologous membrane protein structures (called HOMEP3). Each pair of structures was aligned and the corresponding sequence alignment was used to construct homology models. The model accuracy compared to the known structures was assessed using scoring functions not incorporated in the tested structural alignment methods. The analysis shows that fragment‐based approaches such as FR‐TM‐align are the most useful for aligning structures of membrane proteins. Moreover, fragment‐based approaches are more suitable for comparison of protein structures that have undergone large conformational changes. Nevertheless, no method was clearly superior to all other methods. Additionally, all methods lack a measure to rate the reliability of a position within a structure alignment. To solve both of these problems, we propose a consensus‐type approach, combining alignments from four different methods, namely FR‐TM‐align, DaliLite, MATT, and FATCAT. Agreement between the methods is used to assign confidence values to each position of the alignment. Overall, we conclude that there remains scope for the improvement of structural alignment methods for membrane proteins. Proteins 2015; 83:1720–1732. © 2015 Wiley Periodicals, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号