首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Human seminal plasma has uniquely high concentrations of PGE and 19-hydroxy PGE but the function of these PGs has not been elucidated. PGs of the E series have been shown to be paracrine and autocrine regulators of the function of immune cells and high levels of PGE have been shown consistently to suppress function in such cells. Human seminal plasma has a potent immunosuppressive effect and evidence is accumulating that this is largely due to PG components. In this study the effects of human seminal plasma on the killing activity of natural killer (NK) cells as judged by 51Cr release from K562 cells have been studied in groups of fertile and infertile men. Although there was no significant difference in the PGE, 19-hydroxy PGE or the NK cell inhibitory activity in the two groups, the inhibition of NK cell activity was closely correlated with the PGE and the 19-OH PGE content of the seminal plasma in the fertile group. This finding is further evidence that the major contribution to the immunosuppressive properties of human semen is provide by the high concentration of PGs of the E series in this fluid.  相似文献   

2.
Low concentrations of prostaglandins (PG) could be related to male clinical infertility although relevant experimental data are scarce. The aim of this work is to establish reliable seminal PG levels in fertile men by rigorous sample control, to prevent degradation, and by rapid and simple extraction and assay procedures.Single semen samples from healthy fertile men were immediately centrifuged (within 30 min of ejaculation) adding PGF D4 to the seminal plasma as internal standard. The samples were next ultrafiltered and the PGs in the ultrafiltrate were derivatized with a mixture of N,O-bis(trimethylsilyl)trifluoroacetamide and piperidine (1:1) at 60° for 30 min. Optimum gas—liquid chromatographic separation of all of the peaks of interest was achieved on 4 m × 1/4 in. I.D. Dexsil 300 packed columns at 280°. The detection and quantitation of all the peaks of interest depends on the selected ion monitoring of specific masses. The values obtained (in μg/ml, range in parentheses) were: PGEs, 63.5 ± 49.3 (9–164); PGFs, 2.6 ± 1.92 (0.95–6.63); 19-OH PGEs, 592.6 ± 312.5 (142.1–1047); and 19-OH PGFs, 12.66 ± 5.21 (4–19). Individual values for members of both series I and II are also presented.The sample collection and extraction procedures were further checked by high-performance liquid chromatography on a μPorasil column, with individual isolation and collection of all of the PGs, including the 19-OH PGs not previously separated by liquid chromatography.  相似文献   

3.
Lipid extraction from biological samples is a critical and often tedious preanalytical step in lipid research. Primarily on the basis of automation criteria, we have developed the BUME method, a novel chloroform-free total lipid extraction method for blood plasma compatible with standard 96-well robots. In only 60 min, 96 samples can be automatically extracted with lipid profiles of commonly analyzed lipid classes almost identically and with absolute recoveries similar or better to what is obtained using the chloroform-based reference method. Lipid recoveries were linear from 10-100 μl plasma for all investigated lipids using the developed extraction protocol. The BUME protocol includes an initial one-phase extraction of plasma into 300 μl butanol:methanol (BUME) mixture (3:1) followed by two-phase extraction into 300 μl heptane:ethyl acetate (3:1) using 300 μl 1% acetic acid as buffer. The lipids investigated included the most abundant plasma lipid classes (e.g., cholesterol ester, free cholesterol, triacylglycerol, phosphatidylcholine, and sphingomyelin) as well as less abundant but biologically important lipid classes, including ceramide, diacylglycerol, and lyso-phospholipids. This novel method has been successfully implemented in our laboratory and is now used daily. We conclude that the fully automated, high-throughput BUME method can replace chloroform-based methods, saving both human and environmental resources.  相似文献   

4.
The 2004 Southeast Asia Tsunami killed nearly 5,400 people in Southern Thailand, including foreign tourists and local residents. To recover DNA evidence as much as possible from the seriously decomposed bodies, we explored procedures of sample preparation from both bone and tooth samples as well as both mitochondrial and nuclear markers. Despite having failed to recover enough DNA for nuclear marker typing, we succeeded in obtaining fully informative results for mitochondrial markers (HV1 and HV2) from 258 tooth samples with a success rate of 51% (258/507). Using an organic DNA extraction method coupled with an ultrafiltration step, we obtained 16 STR (including 13 CODIS loci, one sex discrimination locus, and two Identifiler loci) profiles for 834 samples with a success rate of 79% (834/1,062). In addition, by comparing the allelic frequencies between the typed samples as a group and other index populations, we conclude that the Thai tsunami victims are a combined group of several populations. Our results provide valuable evidence and protocols for the future forensic practice.  相似文献   

5.
A simple and reliable method is described which combines ultrafiltration technique with atomic absorption spectrophotometry to determine the Zn fractions in human blood plasma and seminal plasma. Ultrafiltrable, loosely bound, and firmly bound Zn can be measured using this method in the presence or absence of ethylene-diaminetetraacetic acid (EDTA). The YMT membranes for the ultrafiltration must be rinsed thoroughly before use. In contrast to Zn in blood plasma, a large part of Zn in the seminal plasma was found to be ultrafiltrabe. This method can be applied to study the physiologically active part of Zn in body fluids related to various disease states.  相似文献   

6.
Prostaglandins in human seminal plasma. Prostaglandins and related factors 46   总被引:13,自引:0,他引:13  
This study on human seminal plasma sought after the compounds which either possess the dienone chromophore or can be converted into it by treatment with sodium hydroxide. In addition, this investigation led to the isolation of 8 more (PGs) prostaglandins which were present in higher concentrations than the previously recognized PGs. Samples of human seminal plasma were subjected to silicic acid chromatography, reversed phase partition chromatography, thin layer chromatography, and gas liquid chromatography which isolated those 8 PGs not previously recognized. 4 of these compounds, PGE1-217, PGE2-217, PGE1-278, and PGE2-278 were known from earlier studies but had not been isolated from natural sources. The other 4 were 19 hydroxy derivatives of the 4 abovementioned compounds. The concentrations of the previously recognized PGs were recently determined and it was found that the 19 hydroxy derivatives were present in concentrations 4 times higher than the PGE compounds.  相似文献   

7.
An extractor has been developed for microporous membrane liquid–liquid extraction (MMLLE) of lipophilic xenobiotics at trace levels in biological fluids. This new construction allows the sample phase to be stirred, while the organic phase is pumped. The extractor was evaluated using human blood plasma with added organophosphate esters. The size exclusion properties of the membrane reduced lipid co-extraction by 94% compared to ordinary liquid–liquid extraction. In combination with a solid-phase extraction (SPE) step, the method was shown to remove plasma lipids efficiently and thus allow gas chromatographic separation of the compounds. The clean-up method described, including the SPE step, showed a high level of reproducibility, and recoveries of between 72 and 83% were obtained for five of the organophosphate esters after a 200-min extraction period. Using this technique, triphenyl phosphate and an isomer of octyl diphenyl phosphate were detected in human plasma obtained from blood donors. The concentration of triphenyl phosphate ranged between 0.13 and 0.15 μg/g plasma.  相似文献   

8.
Antibodies to the F metabolite 9α, 11α-dihydro-15-keto-prostanoic acid (I), produced in the rabbit, do not cross react with any of the primary PGs. There is a 50% cross reaction with the metabolite 9α, 11α-dihydroxy-15-keto-prost-5-enoic acid (III), and a 23% cross reaction with 9α,11α,15-trihydroxy prostanoic acid (F0α). No cross reactivity resulted with this antiserum when tested against 9α,11α,15-trihydroxy-5-enoic acid (VII) or with 9α,11α-dihydroxy-15-ketoprost-5,13-dienoic acid (VIII). Utilizing this antibody in a radioimmunoassay, some preliminary data are presented on levels of these F metabolites (I and III) for human adult male samples of plasma, urine and seminal plasma.  相似文献   

9.
An efficient extraction procedure for the isolation of prostaglandins (PGs) from biological samples for their subsequent quantification by gas chromatography-electron capture detection (GC-ECD) is described. PGs were extracted from lung, kidney, spleen and stomach fundus into ethyl acetate at different pHs. The highest recovery and least extraction of contaminating pigments was obtained at pH 4.5. Pigments and other contaminants are removed by thin-layer chromatography using a solvent system chloroform-isopropyl alcohol-ethanol-formic acid (45:5:0.5:0.3). The isolated PGs were determined by GC-ECD after appropriate derivatization. The overall recovery of PGs using this procedure is 60%.  相似文献   

10.
Oxidative stress has been proposed as one of the potential causes for infertility in men. Ascorbic acid and uric acid play important role in protection of spermatozoa against free radicals. A method for the simultaneous determination of ascorbic acid and uric acid in human seminal plasma using HPLC with UV detection and investigation their clinical significance as antioxidants protecting male germ cells against oxidative damage are described. Semen samples were obtained from consecutive male partners of couples presenting for a fertility evaluation. After liquefaction, the samples were centrifuged and the supernatants were diluted with dithiothreitol solution and after a filtration injected onto an analytical column. For the separation, a reverse-phase column MAG 1, 250 mm × 4.6 mm, Labiospher PSI 100 C18, 5 μm, was used. The mixture of ethanol and 25 mmol/L sodium dihydrogenphosphate (2.5:97.5, v/v), pH 4.70 was used as a mobile phase. Analytical performance of this method is satisfactory for both ascorbic acid and uric acid: the intra-assay and inter-assay coefficients of variation were below 10%. Quantitative recoveries from spiked seminal plasma were between 92.1 and 102.1%. We have found no significant differences in both ascorbic acid and uric acid concentration between the smokers and non-smokers (351.0 ± 237.9 μmol/L and 323.7 ± 99.5 μmol/L vs. 444.8 ± 245.5 μmol/L and 316.6 ± 108.9 μmol/L, p>0.05). This assay is a simple and reproducible HPLC method for the simultaneous measurement of ascorbic acid and uric acid in human seminal plasma.  相似文献   

11.
About 90% of phospholipase A2 activity detected in human seminal plasma reacted with monoclonal antibodies raised against human synovial fluid phospholipase A2. The crude seminal plasma yielded a pure immuno-cross-reactive phospholipase A2 preparation in a single purification step using immuno-affinity chromatography. The amino acid sequence of the N-terminal 20 residues of this seminal enzyme was determined and found to be identical with that of human synovial phospholipase A2. Thus, it is suggested that human seminal plasma contains phospholipase A2, belonging to the 14-kDa group II enzyme family, as the major isoenzyme.  相似文献   

12.
The endocannabinoids anandamide, palmitoylethanolamide and oleoylethanolamide have been detected in human seminal plasma and are bioactive lipids implicated in regulation of sperm motility, capacitation and acrosome reaction. Several methods exist for endocannabinoid quantification but none have been validated for measurement in human seminal plasma. We describe sensitive, robust, reproducible solid phase and isotope-dilution UHPLC-ESI-MS/MS methods for the extraction and quantification of anandamide, palmitoylethanolamide and oleoylethanolamide in human seminal plasma. Precision and accuracy were evaluated using pooled seminal plasma over a 4 day period. For all analytes, the inter- and intraday precision (CV%) was between 6.6-17.7% and 6.3-12.5%, respectively. Analyses were linear over the range 0.237-19nM for anandamide and oleoylethanolamide and 0.9-76nM for PEA. Limits of detection (signal-to-noise >3) were 50, 100 and 100fmol/mL and limits of quantification (signal-to-noise >10) were 100, 200 and 200fmol/mL, respectively for anandamide, palmitoylethanolamide and oleoylethanolamide. Anandamide and oleoylethanolamide were stable at -80°C for up to 4 weeks, but palmitoylethanolamide declined significantly. We assessed seminal plasma from 40 human donors with normozoospermia and found mean (inter-quartile range) concentrations of 0.21nM (0.09-0.27), 1.785nM (0.48-2.32) and 15.54nM (7.05-16.31) for anandamide, oleoylethanolamide and palmitoylethanolamide, respectively. Consequently, this UHPLC-ESI-MS/MS method represents a rapid, reliable and reproducible technique for the analysis of these endocannabinoids in fresh seminal plasma.  相似文献   

13.
A novel method was developed and assessed to extend the lifetime of extraction columns of high-throughput liquid chromatography (HTLC) for bioanalysis of human plasma samples. In this method, a 15% acetic acid solution and 90% THF were respectively used as mobile phases to clean up the proteins in human plasma samples and residual lipids from the extraction and analytical columns. The 15% acetic acid solution weakens the interactions between proteins and the stationary phase of the extraction column and increases the protein solubility in the mobile phase. The 90% THF mobile phase prevents the accumulation of lipids and thus reduces the potential damage on the columns. Using this novel method, the extraction column lifetime has been extended to about 2000 direct plasma injections, and this is the first time that high concentration acetic acid and THF are used in HTLC for on-line cleanup and extraction column lifetime extension.  相似文献   

14.
A high-performance liquid chromatographic method has been developed and tested for simultaneous extraction, elution and determination of doxorubicin and prochlorperazine content in human plasma samples. The procedure consists of extraction through a conditioned C18 solid-phase extraction cartridge, elution from a Spherisorb C8 reversed-phase column by an isocratic mobile phase (60% acetonitrile, 15% methanol and 25% buffer) followed by detection with electrochemical and fluorescence detectors. Recovery of doxorubicin and prochlorperazine from pooled human plasma samples (n=3) containing 100 ng/ml of the two drugs was 77.8±3.5% and 89.1±6.0%, respectively. The lower limits of quantitation for doxorubicin and prochlorperazine in plasma samples were 6.25 ng/ml and 10 ng/ml, respectively. A linear calibration curve was obtained for up to 2 μg/ml of doxorubicin and prochlorperazine. This combination method may be of particular value in clinical studies where phenothiazines such as prochlorperazine are used to enhance retention of doxorubicin in drug resistant tumor cells.  相似文献   

15.
Two procedures are described for separation and purification of prostaglandins by high performance liquid chromatography. Both systems show excellent resolution of PGA2, PGE2 and PGF2a. Peak definition on the micro-particle silicic acid system is particularly good with the PGs appearing in 2-3 ml of organs effluent. Studies on reproducibility showed that PGE2 and PGE2a could be recovered with a retention volume of 54.2+/-0.76 ml and 64+/-0.6 ml, respectively (n=7, mean +/-50) with good recovery. The column can be run in about one hour and can be regenerated indefinitely (greater than 200 times). The degree of purification is compatible with analysis by gas chromatography-mass spectrometry. Examples showing the application of this chromatographic method to human seminal fluid, human renal tissue, platelet rich plasma and human urine samples indicate that it makes possible analysis of these samples even at low levels.  相似文献   

16.
L K Unni  S M Somani 《Life sciences》1985,36(14):1389-1396
The binding of 3H-physostigmine (3H-Ph) to human and rat plasma proteins and crystalline serum albumin was studied by ultrafiltration technique. This study showed that the percentage of 3H-Ph bound to rat plasma slightly decreased from 49% to 41% whereas human plasma showed an increase in binding from 29% to 43% over a 50-fold increase in drug concentration. Human plasma samples which were collected in a bag coated with citrate phosphate dextrose adenine-1 solution bound 50% less 3H-Ph than samples collected with EDTA indicating a drug-drug interaction between 3H-Ph and anticoagulants. No significant change in binding was observed if the samples were frozen prior to use. Scatchard plots for binding of 3H-Ph resulted in a positive slope for human plasma and a negative slope for rat plasma; whereas curvilinear Scatchard plots with negative slopes were obtained for binding to human and rat crystalline serum albumin.  相似文献   

17.
For the implementation and validation of an automated `high-throughput' solid-phase extraction (SPE) system, using microtiter solid-phase technology and a pipetting robot, a SPE method previously validated manually for cimetidine in human plasma was adapted. Sample cleanup was performed by means of SPE using Microlute extraction plates in the 96-well format, each well filled with 50 mg of Varian C18 sorbent. Separation was performed by reversed-phase high-performance liquid chromatography (HPLC) with UV detection at 234 nm. The validated calibration range was from 0.100 to 5.00 mg/l, with an inaccuracy and imprecision below 20% at all concentration levels. Validation results on linearity, specificity, precision, accuracy and stability are shown and are found to be adequate. Cross-check analysis of samples from a clinical trial showed that there is a good correlation between results obtained by the automated method and results obtained by the manual method. The average sample preparation time for a technician decreased from approximately 4 min per sample to 0.6 min. A sample throughput of at least 160 samples per day can be achieved, the HPLC analysis time being the rate-limiting step.  相似文献   

18.
Two procedures are described for separation and purification of prostaglandins by high performance liquid chromatography. Both systems show excellent resolution of PGA2, PGE2 and PGF. Peak definition on the micro-particle silicic acid system is particularly good with the PGs appearing in 2–3 ml of organic effluent. Studies on reproducibility showed that PGE2 and PGF could be recovered with a retention volume of 54.2±0.76 ml and 64±0.6 ml, respectively (n=7, mean ±SD) with good recovery. The column can be run in about one hour and can be regenerated indefinitely (>200 times). The degree of purification is compatible with analysis by gas chromatography-mass spectrometry. Examples showing the application of this chromatographic method to human seminal fluid, human renal tissue, platelet rich plasma and human urine samples indicate that it makes possible analysis of these samples even at low levels.  相似文献   

19.
A method is described for the determination of pilocarpine and its degradation products isopilocarpine, pilocarpic acid and isopilocarpic acid in human plasma and urine. The method is based on a simple sample preparation step – ultrafiltration for plasma and dilution for urine samples – followed by a reversed-phase liquid chromatographic separation of the analytes and detection by means of tandem mass spectrometry. Parameters affecting the performance of these steps are discussed. The high sensitivity and selectivity of the method allow low ng/ml concentrations to be determined for all compounds in plasma and undiluted urine, which enables the investigation of the metabolic fate and elimination of pilocarpine after oral administration to humans.  相似文献   

20.
Due to the low percentage of fetal DNA present in maternal plasma (< 10%) during early gestation, efficient extraction processes are required for successful downstream detection applications in non-invasive prenatal diagnostic testing. In this study, two extraction methods using similar chemistries but different workflows were compared for isolation efficiency and percent fetal DNA recovery. The Akonni Biosystems TruTip technology uses a binding matrix embedded in a pipette tip; the Circulating Nucleic Acids Kit from Qiagen employs a spin column approach. The TruTip method adds an extra step to decrease the recovery of DNA fragments larger than 600 bp from the sample to yield an overall higher percentage of smaller molecular weight DNA, effectively enriching for fetal DNA. In this evaluation, three separate extraction comparison studies were performed - a dilution series of fragmented DNA in plasma, a set of clinical maternal samples, and a blood collection tube time point study of maternal samples. Both extraction methods were found to efficiently extract small fragment DNA from large volumes of plasma. In the amended samples, the TruTip extraction method was ~15% less efficient with overall DNA recovery, but yielded an 87% increase in % fetal DNA relative to the Qiagen method. The average percent increase of fetal DNA of TruTip extracted samples compared to the Qiagen method was 55% for all sets of blinded clinical samples. A study comparing extraction efficiencies from whole blood samples incubated up to 48 hours prior to processing into plasma resulted in more consistent % fetal DNA recoveries using TruTip. The extracted products were tested on two detection platforms, quantitative real-time PCR and droplet digital PCR, and yielded similar results for both extraction methods.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号