首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Cross-linking technology combined with tandem mass spectrometry (MS-MS) is a powerful method that provides a rapid solution to the discovery of protein-protein interactions and protein structures. We studied the problem of detecting cross-linked peptides and cross-linked amino acids from tandem mass spectral data. Our method consists of two steps: the first step finds two protein subsequences whose mass sum equals a given mass measured from the mass spectrometry; and the second step finds the best cross-linked amino acids in these two peptide sequences that are optimally correlated to a given tandem mass spectrum. We designed fast and space-efficient algorithms for these two steps and implemented and tested them on experimental data of cross-linked hemoglobin proteins. An interchain cross-link between two beta subunits was found in two tandem mass spectra. The length of the cross-linker (7.7 A) is very close to the actual distance (8.18 A) obtained from the molecular structure in PDB.  相似文献   

2.
Salek M  Lehmann WD 《Proteomics》2005,5(2):351-353
Peptides containing a monoiodo- or diiodo-tyrosine residue (monoiodo-Y, diiodo-Y) were found to generate abundant immonium ions following collision-induced dissociation at m/z 261.97 and 387.87 Da, respectively. These residue-specific marker ions are between about 140 mDa (monoiodo-Y) and 300 mDa (diiodo-Y) mass deficient relative to any other peptide fragment ions of unmodified peptides, qualifying them as highly specific marker ions for tyrosine iodination when analyzed by high resolution tandem mass spectrometry (MS/MS). Two new iodination sites (Y-364 and Y-2165) were pinpointed in bovine thyroglobulin by MS/MS using these iodotyrosine-specific marker ions and combined tryptic/chymotryptic digestion.  相似文献   

3.
The accurate mass values of all immonium, y(1), y(2), a(2), and b(2) ions of tryptic peptides composed of the 20 standard amino acids were calculated. The differences between adjacent masses in this data set are greater than 10 mDa for more than 80% of the values. Using this mass list, the majority of low mass ions in quadrupole-time of flight tandem mass spectra of peptides from tryptic digests and from an elastase digest could be assigned. Besides the a(2)/b(2) ions, which carry residues 1-2 from the N-terminus, a variety of internal dipeptide b ions were regularly observed. In case internal proline was present, corresponding dipeptide b ions carrying proline at the N-terminal position occurred. By assigning the dipeptide b ions on the basis of their accurate mass, bidirectional or unidirectional sequence information was obtained, which is localized to the peptide N-terminus (a(2)/b(2) ions) or not localized (internal b ions). Identification of the y(1) and y(2) ions by their accurate mass provides unidirectional sequence information localized to the peptide C-terminus. It is shown that this patchwork-type sequence information extractable from accurate mass data of low-mass ions is highly efficient for protein identification.  相似文献   

4.
Rabbit lung flavin-containing monooxygenase (FMO, EC 1.14.13.8) was denatured, reduced, carboxymethylated, digested with endoproteinase Glu-C or trypsin, and subjected to mass spectrometric analysis. The amino acid sequences of selected peptides were determined by tandem mass spectrometry. Over 90% of rabbit lung FMO was mapped by liquid secondary ion mass spectrometry (LSIMS). The FMO N-terminal amino acid was found to be N-acetylated, and the N-terminal 23 amino acid peptide contained an FAD binding domain consisting of Gly-X-Gly-X-X-Gly. Another peptide was found to contain a NADP+ binding domain consisting of Gly-X-Gly-X-X-Ala. The mapped and/or sequenced peptides were found to be completely consistent with the peptide sequence deduced from the cDNA data and the previously published gas-phase sequencing data. Further mass spectrometry and protein analytical work unambiguously showed that rabbit lung FMO existed in tight association with a calcium-binding protein, calreticulin. Over 68% of rabbit lung calreticulin was mapped by LSIMS. Tandem mass spectrometric and gas-phase sequencing studies provided direct evidence for the identification of the N-terminal and other rabbit lung calreticulin-derived peptide sequences that were identical to other previously reported calreticulins. The complexation of calreticulin to rabbit lung FMO could account for some of the unusual physical properties of this FMO enzyme form.  相似文献   

5.
The peptide hormones guanylin and uroguanylin are ligands of the intestinal guanylyl cyclase-C (GC-C) that is involved in the regulation of epithelial water and electrolyte transport. The small peptides contain 15 and 16 amino acids, respectively, and two disulfide bonds with a 1-3/2-4 connectivity. This structural feature causes the unique existence of two topological isoforms for each peptide in an approximate 3:2 ratio, with only one of the isoforms exhibiting GC-C-activating potential. The two uroguanylin isomers can be separated by HPLC and are of sufficient stability to be studied separately at ambient temperatures while the two guanylin isomers are rapidly interconverting even at low temperatures. Both isomers show clearly distinguishable (1)H chemical shifts. To investigate the influence of certain amino acid side chains on this isomerism and interconversion kinetics, derivatives of guanylin and uroguanylin (L-alanine scan and chimeric peptides) were designed and synthesized by Fmoc solid-phase chemistry and compared by HPLC and 2D (1)H NMR spectroscopy. Amino acid residues with the most significant effects on the interconversion kinetics were predominantly identified in the COOH-terminal part of both peptides, whereas amino acids in the central part of the peptides only moderately affected the interconversion. Thus, the conformational conversion among the isomers of both peptides is under the control of a COOH-terminal sterical hindrance, providing a detailed model for this dynamic isomerism. Our results demonstrate that kinetic control of the interconversion process can be achieved by the introduction of side chains with a defined sterical profile at suitable sequence positions. This is of potential impact for the future development of GC-C peptide agonists and antagonists.  相似文献   

6.
Bandeira N 《BioTechniques》2007,42(6):687, 689, 691 passim
Significant technological advances have accelerated high-throughput proteomics to the automated generation of millions of tandem mass spectra on a daily basis. In such a setup, the desire for greater sequence coverage combines with standard experimental procedures to commonly yield multiple tandem mass spectra from overlapping peptides-typical observations include peptides differing by one or two terminal amino acids and spectra from modified and unmodified variants of the same peptides. In a departure from the traditional spectrum identification algorithms that analyze each tandem mass spectrum in isolation, spectral networks define a new computational approach that instead finds and simultaneously interprets sets of spectra from overlapping peptides. In shotgun protein sequencing, spectral networks capitalize on the redundant sequence information in the aligned spectra to deliver the longest and most accurate de novo sequences ever reported for ion trap data. Also, by combining spectra from multiple modified and unmodified variants of the same peptides, spectral networks are able to bypass the dominant guess/confirm approach to the identification of posttranslational modifications and alternatively discover modifications and highly modified peptides directly from experimental data. Open-source implementations of these algorithms may be downloaded from peptide.ucsd.edu.  相似文献   

7.
A combination of split-field drift tube/mass spectrometry and isotopic labeling techniques is evaluated as a means of identifying single amino acid polymorphisms (SAAPs) in proteins. The method is demonstrated using cytochromec (equine and bovine) and hemoglobin (bovine and sheep). For these studies, proteins from different species are digested with trypsin, and the peptides are labeled at primary amine groups [using either a light (H(3))- or heavy (D(3))-isotopic reagent]. SAAP analysis is carried out by mixing the light-labeled peptides of one species with the heavy-labeled peptides of the other and electrospraying the resulting mixture into a split-field drift tube/mass spectrometer. Peptides having the same sequence in both species appear as doublets in the mass spectrum [shifted in mass-to-charge (m/z) according to the number of incorporated labels]; additionally, these species have identical mobility distributions. Peptides having sequences that differ by one amino acid appear as peaks in the mass spectrum that are shifted in m/z according to the mass difference associated with the SAAP and the number of incorporated labels. The ion mobility distributions for these peptides (differing by only a single amino acid) can often be rationalized by their expected similarities or differences providing additional evidence that they are related. In all, 12 and 26 peptide variants (between species) corresponding to 5 and 11 amino acid polymorphisms have been identified for the cytochrome c and hemoglobin protein samples, respectively.  相似文献   

8.
Intracellular Ags are processed into small peptides that are presented on cell surfaces in the context of HLA class I molecules. These peptides are recognized by TCRs displayed by CD8+ T lymphocytes (T cells). To date, direct identification and quantitation of these peptides has relied primarily on mass spectrometry analysis, which is expensive and requires large quantities of diseased tissues to obtain useful results. Here we demonstrate that multimerization of a soluble single-chain TCR (scTCR), recognizing a peptide from p53 presented in the context of HLA-A2.1, could be used to directly visualize and quantitate peptide/MHC complexes on unmanipulated human tumor cells. Tumor cells displaying as few as 500 peptide/MHC complexes were readily detectable by flow cytometry. The scTCR/multimers exhibited exquisite recognition capability and could distinguish peptides differing in as little as a single amino acid. We also demonstrate that scTCR/multimers could specifically stain human tumors generated in mice, as well as tumors obtained from patient biopsies. Thus, scTCR/multimers represent a novel class of immunostaining reagents that could be used to validate, quantitate, or monitor epitope presentation by cancer cells.  相似文献   

9.
In high-throughput proteomics the development of computational methods and novel experimental strategies often rely on each other. In certain areas, mass spectrometry methods for data acquisition are ahead of computational methods to interpret the resulting tandem mass spectra. Particularly, although there are numerous situations in which a mixture tandem mass spectrum can contain fragment ions from two or more peptides, nearly all database search tools still make the assumption that each tandem mass spectrum comes from one peptide. Common examples include mixture spectra from co-eluting peptides in complex samples, spectra generated from data-independent acquisition methods, and spectra from peptides with complex post-translational modifications. We propose a new database search tool (MixDB) that is able to identify mixture tandem mass spectra from more than one peptide. We show that peptides can be reliably identified with up to 95% accuracy from mixture spectra while considering only a 0.01% of all possible peptide pairs (four orders of magnitude speedup). Comparison with current database search methods indicates that our approach has better or comparable sensitivity and precision at identifying single-peptide spectra while simultaneously being able to identify 38% more peptides from mixture spectra at significantly higher precision.  相似文献   

10.
The peptides released from beta-casein by the action of PI-type proteinase (PrtP) from Lactococcus lactis subsp. cremoris Wg2 have been identified by on-line coupling of liquid chromatography to mass spectrometry. After 24 h of incubation of beta-casein with purified PrtP, a stable mixture of peptides was obtained. The trifluoroacetic acid-soluble peptides of this beta-casein hydrolysate were fractionated by high-performance liquid chromatography and introduced into the liquid chromatography-ion spray mass spectrometry interface. Multiply charged ions were generated from trifluoroacetic acid-soluble peptides under low nozzle voltage conditions, yielding the MH+ mass of each eluted peptide. All peptides corresponding to each of the MH+ calculated masses were determined. In those cases in which different peptides were possible, further identification was achieved by collision-induced dissociation under higher nozzle voltage conditions. Hydrolysis of beta-casein by PrtP was observed to proceed much further than reported previously. More than 40% of the peptide bonds are cleaved by PrtP, resulting in the formation of more than 100 different oligopeptides. With the exception of Phe, significant release of amino acids or di- and tripeptides could not be observed. Interestingly, one-fifth of the identified oligopeptides are small enough to be taken up by the oligopeptide transport system. Uptake of these peptides could supply L. lactis with all amino acids, including the essential ones, indicating that growth of L. lactis might be possible on peptides released from beta-casein by proteinase only.  相似文献   

11.
Microcystins (MC) and nodularins (Nod) are cyclic peptide hepatotoxins and tumour promoters produced by cyanobacteria. This study deals with liquid chromatography–mass spectrometry (LC–MS) analyses of 9 major cyanobacterial peptide toxins, starting with a comparison of six small particle size reversed-phase HPLC columns, from which one, Phenomenex Synergi Hydro-RP, was chosen for further chromatography with accurate mass MS studies in a complex biological fluid, serum. The instrumentation used for the serum sample analysis included a Bruker micrO-TOF-Q-MS coupled to an Agilent 1200RR LC system. Total analysis run time per sample was 8.5 min. The Q-TOF-MS instrument was operated on auto MS–MS mode to obtain fragment ions (such as the characteristic fragment m/z 135 from Adda amino acid residue) for toxin identification purposes. Detected mass errors in serum samples were in the range of from 0.3 mDa to 9.1 mDa. The narrow mass window (±20 mDa) for mass chromatograms used in quantitation gave benefits by background noise reduction. We conclude that a LC–ESI-Q-TOF-MS instrumentation is a powerful tool for identification and quantitation of cyanobacterial peptide toxins in a biological matrix.  相似文献   

12.
The proliferative responses of a human CD4+ T cell clone 29.15.2, reactive with a self-K-ras-derived peptide (3EYKLVVVGAGGVGKSALT20), were tested using a set of X9 combinatorial peptide libraries containing the flanking residues (EYKLVXXXXXXXXXSALT, where X indicates random amino acids). Certain peptide libraries, such as EYKLVXXXXXXM XXSALT and EYKLVXXXXXXXH XSALT, stimulated a marked proliferation of 29.15.2. However, no combinations of substitutions tested, such as EYKLVXXXXXXMH XSALT, exhibited additive effects. We subsequently synthesized peptides with degenerate sequences (a mixture of 480 species), where each position is composed of the wild-type (wt) residue or of amino acids that induced the proliferation of 29.15.2, in positional scanning. Interestingly, one fraction of degenerate peptides, separated by reverse-phase HPLC, stimulated much higher proliferation than did the wt; in addition, the retention time of this fraction was distinct from that of the wt. Mass spectrometry analysis of this fraction and flanking fractions identified five peptide species that exhibit strong signals in a manner that parallels the antigenic activity. Finally, 17 candidate peptide sequences were deduced from mass spectrometry and hydrophobicity scoring results, of which two peptides (EYKLVVVGAGGML KSALT and EYKLVVVGAGGMI KSALT) did induce 52- and 61-fold stronger proliferation, respectively, compared with the wt. These findings indicate that: 1) synthetic peptides that carry "the best" residue substitution at each position of combinatorial peptide libraries do not always exhibit superagonism, and 2) such a drawback can be overcome with the use of mass spectrometry. This approach provides new perspectives for the accurate and efficient identification of peptide superagonists.  相似文献   

13.
A potent and persistent non-mammalian derived vasodilator, maxadilan (Maxa) consists of 61 amino acids with two disulfide linkages and acts as an agonist of the type I receptor of pituitary adenylate cyclase activating polypeptide (PACAP), although there is very little sequence similarity. The total chemical syntheses of Maxa, its disulfide isomers and various fragments have been performed successfully by highly efficient solid-phase peptide synthesis (SPPS). A “difficult sequence”, envisaged in the middle region of Maxa, could be overcome by improved synthesis protocols. After assembly peptides were liberated from the resin by cleavage. Peptides having disulfide(s) were purified by two steps of preparative HPLC using cation exchange followed by reverse phase columns. Purified peptides were characterized by HPLC, Edman-sequencing, amino acid analysis and mass spectrometry in addition to disulfide form determination. The peptides obtained were used for recognition studies by the melanophore assay to confirm the native disulfide form. Peptide libraries related to Maxa, produced in the present study, will be useful for the elucidation of the structural requirements of Maxa for interaction with the PACAP type 1 receptor (PAC1). This paper is dedicated to the memory of Professor Bruce Merrifield, a pioneer and one of the most respected experimental scientists, who made extraordinary contributions to high throughput chemical synthesis.  相似文献   

14.
We utilized radioactive 73As-labeled arsenite and vacuum filtration methodology to determine the binding affinity of arsenite to eight synthetic peptides ranging from 13 to 24 amino acids long and containing one or two cysteines separated by 0-17 intervening amino acids. Six of the eight peptides were highly similar in amino acid sequence and were based on cysteine containing regions of the hormone-binding site of the human estrogen receptor-alpha (e.g., the sequence of peptide 28 is LEGAWCGKGVEGTEHLYSMKCKNV). The peptides with 0-14 intervening amino acids between two cysteines bound arsenite with Kd values of 2.7-20.1 uM and with Bmax values from 36 to 103 nmol/mg protein (from 0.083 to 0.19 nmol/nmol of protein). Thus, increasing the number of intervening amino acids from 0 to 14 made very little difference in the observed Kd values for arsenite, a surprising finding. Therefore, these peptides are flexible in solution and effectively contain a dithiol high affinity binding site for arsenite. Peptide 17 with two C separated by 19 amino acids bound arsenite with a Kd of 123 uM and a Bmax of 41.8 nmol/mg. The monothiol peptide 19 bound arsenite with a Kd of 124 uM and a Bmax of 26 nmol/mg protein. All experimental binding curves fit well to a one site binding model.  相似文献   

15.
It is difficult to understand the functional mechanisms of integral membrane proteins without having protein chemical information on these proteins. Although there have been many attempts to identify functionally important amino acids in membrane proteins, chemically and enzymatically cleaved peptides of integral membrane proteins have been difficult to handle because of their hydrophobic properties. In the present study, we have applied an analytical method to transmembrane proteins combining amino acid sequencing, matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry, and liquid chromatography with electrospray ionization (LC/ESI) mass spectrometry. We could analyze most (97%) of the tryptic fragments of the transmembrane domains of band 3 as well as other minor membrane proteins. The peptide mapping of the transmembrane domain of band 3 was completed and the peptide mapping information allowed us to identify the fragments containing lysine residues susceptible to 4-acetamido-4'-isothiocyanatostilbene-2,2'-disulfonic acid (SITS) and to 2,4-dinitrofluorobenzene (DNFB). This method should be applicable to membrane proteins not only in erythrocyte membranes but also in other membranes.  相似文献   

16.
For the identification of peptides with tandem mass spectrometry (MS/MS), many software tools rely on the comparison between an experimental spectrum and a theoretically predicted spectrum. Consequently, the accurate prediction of the theoretical spectrum from a peptide sequence can potentially improve the peptide identification performance and is an important problem for mass spectrometry based proteomics. In this study a new approach, called MS-Simulator, is presented for predicting the y-ion intensities in the spectrum of a given peptide. The new approach focuses on the accurate prediction of the relative intensity ratio between every two adjacent y-ions. The theoretical spectrum can then be derived from these ratios. The prediction of a ratio is a closed-form equation that involves up to five consecutive amino acids nearby the two y-ions and the two peptide termini. Compared with another existing spectrum prediction tool MassAnalyzer, the new approach not only simplifies the computation, but also improves the prediction accuracy.  相似文献   

17.
In this study, mesoporous silicate was applied as a matrix for the analysis of various molecules from small molecules to medium sized peptides in laser desorption/ionization mass spectrometry. In contrast with conventional matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS), the proposed approach desorption/ionization on mesoporous silicate mass spectrometry (DIOM-MS), significantly reduces the problem of matrix interference in low mass region and can be applied to the analysis of versatile chemicals including amino acids, synthetic drugs, peptides and others. In addition, distinctive advantage of DIOM-MS showed higher salt tolerance and could be applied to identify the proteins from the analysis of tryptically digested peptides. DIOM-MS has several availabilities such as easy sample preparation, rapid analysis of small molecules without noise, peptide analysis without organic matrix, high salt tolerance, versatile coupling with other separation techniques, and high throughput manner.  相似文献   

18.
Protein identification by mass spectrometry is mainly based on MS/MS spectra and the accuracy of molecular mass determination. However, the high complexity and dynamic ranges for any species of proteomic samples, surpass the separation capacity and detection power of the most advanced multidimensional liquid chromatographs and mass spectrometers. Only a tiny portion of signals is selected for MS/MS experiments and a still considerable number of them do not provide reliable peptide identification. In this article, an in silico analysis for a novel methodology of peptides and proteins identification is described. The approach is based on mass accuracy, isoelectric point (pI), retention time (t(R)) and N-terminal amino acid determination as protein identification criteria regardless of high quality MS/MS spectra. When the methodology was combined with the selective isolation methods, the number of unique peptides and identified proteins increases. Finally, to demonstrate the feasibility of the methodology, an OFFGEL-LC-MS/MS experiment was also implemented. We compared the more reliable peptide identified with MS/MS information, and peptide identified with three experimental features (pI, t(R), molecular mass). Also, two theoretical assumptions from MS/MS identification (selective isolation of peptides and N-terminal amino acid) were analyzed. Our results show that using the information provided by these features and selective isolation methods we could found the 93% of the high confidence protein identified by MS/MS with false-positive rate lower than 5%.  相似文献   

19.
Hollemeyer K  Heinzle E  Tholey A 《Proteomics》2002,2(11):1524-1531
Oxidation of methionine residues in peptides and proteins occurs in vivo or may be an artifact resulting from purification steps. We present a three step method for the localization of methionine sulfoxides in peptides with two methionine residues. In the first step, the N-terminus as well as other reactive side chain functions are blocked by acetylation. The resulting protected peptides are cleaved by cyanogen bromide. The cleavage does not occur at methionine sulfoxide but only at reduced methionine residues forming new amino termini. The newly formed amino group is then derivatized with a bromine containing compound in the last step of the procedure. The resulting peptide can easily be identified by matrix-assisted laser desorption/ionization-time of flight mass spectrometry using both the characteristic isotope pattern of the halogen and the metastable loss of methanesulfenic acid from oxidized residues. This procedure allows the unequivocal localization of oxidized methionines even in complex peptide mixtures.  相似文献   

20.
Methods for on-chip protein analysis   总被引:7,自引:0,他引:7  
The unambiguous identification of peptides/proteins is crucial for the definition of the proteome. Using ProteinChip Array technology also known as surface-enhanced laser desorption/ionization-time of flight mass spectrometry (SELDI-TOF MS), we developed experimental protocols and probed test conditions required for the protein identification on ProteinChip surfaces. We were able to directly digest peptides/proteins on-chip surfaces by specific proteases, such as trypsin, and to obtain the peptide mass fingerprint of the sample under investigation by its direct analysis on a simple laser desorption/ionization mass spectrometer. Furthermore, tandem mass spectrometry was performed on several of the resulting tryptic peptides by using collision quadrupole time of flight (Qq-TOF) MS/MS via the ProteinChip interface, thus allowing the unambiguous identification of the protein(s) within the sample. In addition, we were able to identify the C-terminal sequence of peptides by their digestion with carboxypeptidase Y directly on ProteinChip surfaces coupled with SELDI-TOF MS analysis of the resulting peptide mass ladders employing the instrument's protein ladder sequence software. Moreover, the removal of up to nine amino acid residues from the C-terminal end of a peptide extends the functional range of Qq-TOF MS/MS sequence determination to over 3000 m/z. The utility of these procedures for the proteome exploration are discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号