首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Patients with native valve endocarditis treated surgically between 1968 and 1978 (n = 15) and all patients presenting with prosthetic valve endocarditis during this period (n = 21) were followed up for at least four years. Five of the patients with native valve endocarditis required urgent early surgical intervention, of whom two died. The remaining 10 underwent valve replacement after a course of antibiotic treatment: all survived, though one required further valve replacement. The 21 patients with prosthetic valve endocarditis suffered 25 attacks. Nine were cured by medical treatment alone; two died before surgical intervention was possible; 11 required valve replacement, of whom three died; and two required valve replacement after a course of antibiotic treatment. The incidence of early prosthetic valve endocarditis--that occurring within two months of operation--was 0.67%, but that of late prosthetic valve endocarditis could not be determined. Medical treatment when started early should cure endocarditis in most patients, but vigilance should be maintained for the appearance of indications for surgery. When such indications exist surgery should not be delayed.  相似文献   

2.
The aim of this randomized, prospective, study was to evaluate postoperative hospital mortality and morbidity after mitral valve repair by comparing two surgical techniques for resolving mitral valve insufficiency in elderly patients. In comparison were: mitral valve repair vs. mitral valve replacement in patients older than 70 years. In period from January 1st 2006 until August 30th 2009. Eighty patients with mitral valve disease, isolated or associated with other comorbidities, were scheduled for mitral valve repair or mitral valve replacement in our institution. Patients were randomized in two groups, one scheduled for mitral valve repair and another one for mitral valve replacement using the envelope method with random numbers. Results show no difference in hospital mortality and morbidity postoperatively in both groups. In group undergoing valve replacement we had one significant complication of ventricle rupture in emphatically calcified posterior part of mitral valve annulus. In conclusion we found no distinction in postoperative hospital mortality and morbidity after using one of two surgical techniques.  相似文献   

3.
The mitral valve, as an active flap, forms the major part of the left ventricular inflow tract and therefore plays an important function in many aspects of left ventricular performance. The anterior leaflet of this valve is the largest and most ventrally placed of two leaflets that come together during ventricular systole to close the left atrioventricular orifice. Various neurotransmitters are responsible for different functions including controlling valve movement, inhibiting or causing the failure of impulse conduction in the valve and the sensation of pain. Nitric oxide acts as a gaseous free radical neurotransmitter, neuromediator and effective cardiovascular modulator. Acetyl-choline is known to function as a typical neurotransmitter. Histochemical methods for detection of nicotinamide adenine dinucleotide phosphate diaphorase (NADPH-d), as an indirect nitric oxide-synthase marker, and method for detection of acetylcholinesterase (AChE) were used. Both methods were performed on the same valve sample. A widespread distribution of nerve fibres was observed in the anterior leaflet of the mitral valve. The fine NADPH-d positive (nitrergic) nerve fibres were identified in all zones of valve leaflet. AChE positive (cholinergic) nerve fibres were identified forming dense network and fibres organized in stripes. Endocardial cells and vessels manifested heavy NADPH-d activity. Our observations suggest a different arrangement of nitrergic and cholinergic nerve fibres in the anterior leaflet of the mitral valve. The presence of nitrergic and cholinergic activity confirms the involvement of both neurotransmitters in nerve plexuses and other structures of mitral valve.Key words: NADPH-diaphorase, acetylcholinesterase, heart, mitral valve, nerve fibres, vessels, rat.  相似文献   

4.
Dissatisfaction with the hemodynamic characteristics of available porcine valves prompted a clinical trial of the Ionescu-Shiley percardial xenograft (ISPX) valve. Three hundred fifty-six ISPX valves were implanted consecutively in 326 patients. Operative mortality was 2.6% (2/75) for aortic valve replacement alone and 7.7% (12/155) for aortic valve replacements that included reoperations and combined procedures such as mitral commissurotomy, annuloplasty, and coronary artery bypass. Operative mortality for all patients who underwent mitral valve replacement was 9.5% (14/147). The mean peak systolic gradient pressure in the aortic position was 5.4 mm Hg overall and 4.27 mm Hg with the size 19 mm valve. There were no embolic episodes in patients who received the ISPX valve in the aortic position. The available data indicate that the rate of peripheral embolism with the ISPX valve compares favorably with that of porcine valves. Considering its hemodynamic advantage, if the longterm durability of the full-orifice Ionescu-Shiley pericardial xenograft valve continues to be confirmed by follow-up studies, it is our opinion that it is the biologic valve of choice.  相似文献   

5.
目的:分析老年瓣膜病在瓣膜置换术后的死亡原因,为降低术后死亡率提供科学依据。方法:回顾分析我院以瓣膜置换术治疗的329例老年瓣膜病变患者的资料,对比分析生存患者和死亡患者之间的差异,总结瓣膜置换术后患者死亡的危险因素。结果:心脏瓣膜置换术后死亡率8.51%,单因素分析发现年龄、心功能分级、置换瓣膜数、LAD、LVEF、LVEDD、CPB时间、主动脉阻断时间、置换瓣膜数目与术后死亡有关联(P0.05),Logistic回归分析发现高龄、心功能差、LVEED、CPB为死亡独立危险因素(P0.05)。结论:高龄、心功能差、LVEED过度增大、CPB过长均是瓣膜置换术后的老年瓣膜病患者死亡的独立危险因素,建议临床在诊治中加以警惕。  相似文献   

6.
7.
8.
In this paper, a numerical simulation of steady laminar and turbulent flow in a two-dimensional model for the total artificial heart is presented. A trileaflet polyurethane valve was simulated at the outflow orifice while the inflow orifice had a trileaflet or a flap valve. The finite analytic numerical method was employed to obtain solutions to the governing equations in the Cartesian coordinates. The closure for turbulence model was achieved by employing the k-epsilon-E model. The SIMPLER algorithm was used to solve the problem in primitive variables. The numerical solutions of the simulated model show that regions of relative stasis and trapped vortices were smaller within the ventricular chamber with the flap valve at the inflow orifice than that with the trileaflet valve. The predicted Reynolds stresses distal to the inflow valve within the ventricular chamber were also found to be smaller with the flap valve than with the trileaflet valve. These results also suggest a correlation between high turbulent stresses and the presence of thrombus in the vicinity of the valves in the total artificial hearts. The computed velocity vectors and turbulent stresses were comparable with previously reported in vitro measurements in artificial heart chambers. Analysis of the numerical solutions suggests that geometries similar to the flap valve (or a tilting disk valve) results in a better flow dynamics within the total artificial heart chamber compared to a trileaflet valve.  相似文献   

9.
目的:比较行不同成形术治疗风湿性二尖瓣病变合并功能性三尖瓣关闭不全的外科疗效。方法:选取风湿性二尖瓣病变合并功能性三尖瓣关闭不全患者119例,按照治疗方法将患者分为对照组、三尖瓣人工环植入成形术组(成形环组)以及三尖瓣缝线成形术(缝线组),分别统计患者年龄、性别、手术方式、术前及术后心功能分级等指标,采用t检验对患者术前、术后2周以及术后6个月心脏各腔内径进行统计学分析。结果:患者行三尖瓣人工环植入成形术以及三尖瓣缝线成形术治疗后,心脏各腔内径均明显缩小,成形环组患者术后心脏内径缩小最显著,行三尖瓣缝线成形术患者次之。术前成形环组左心房、右心房以及右心室内径较对照组扩大明显(P0.05);术前缝线组左心房、右心房以及右心室内径较对照组扩大明显(P0.05);术前成形环组与缝线组右心房、右心室内径组间无明显差异;术后2周以及术后6个月三组间左心房内径无明显差异(P0.05)。术后2周成形环组以及缝线组右心房以及右心室内径仍大于对照组(P0.05),术前成形环组与缝线组组间无显著差异。术后6个月成形环组右心房以及右心室内径较缝线组显著缩小(P0.05),成形环组和对照组间无明显差异。结论:治疗风湿性二尖瓣病变合并功能性三尖瓣关闭不全的方法中,三尖瓣人工环植入成形术效果优于三尖瓣缝线环缩术。  相似文献   

10.
The Gorlin equation for the hemodynamic assessment of valve area is commonly used in cardiac catheterization laboratories. A study was performed to test the prediction capabilities of the Gorlin formula as well as the Aaslid and Gabbay formula for the effective orifice area of prosthetic heart valves. Pressure gradient, flow, and valve opening area measurements were performed on four 27 mm valve prostheses (two mechanical bileaflet designs, St. Jude and Edwards-Duromedics, an Edwards pericardial tissue valve, and a trileaflet polyurethane valve) each mounted in the aortic position of an in vitro pulse duplicator. With the known valve orifice area, a different discharge coefficient was computed for each of the four valves and three orifice area formulas. After some theoretical considerations, it was proposed that the discharge coefficient would be a function of the flow rate through the valve. All discharge coefficients were observed to increase with increasing systolic flow rate. An empirical relationship of discharge coefficient as a linear function of systolic flow rate was determined through a regression analysis, with a different relationship for each valve and each orifice area formula. Using this relationship in the orifice area formulas improved the accuracy of the prediction of the effective orifice area with all three formulas performing equally well.  相似文献   

11.
The prevalence of aortic valve stenosis (AS) is increasing in the aging society. More recently, novel treatments and devices for AS, especially transcatheter aortic valve replacement (TAVR) have significantly changed the therapeutic approach to this disease. Research and development related to TAVR require testing these devices in the calcified heart valves that closely mimic a native calcific valve. However, no animal model of AS has yet been available. Alternatively, animals with normal aortic valve that are currently used for TAVR experiments do not closely replicate the aortic valve pathology required for proper testing of these devices. To solve this limitation, for the first time, we developed a novel polymeric valve whose leaflets possess calcium hydroxyapatite inclusions immersed in them. This study reports the characteristics and feasibility of these valves. Two types of the polymeric valve, i.e., moderate and severe calcified AS models were developed and tested by deploying a transcatheter valve in those and measuring the related hemodynamics. The valves were tested in a heart flow simulator, and were studied using echocardiography. Our results showed high echogenicity of the polymeric valve, that was correlated to the severity of the calcification. Aortic valve area of the polymeric valves was measured, and the severity of stenosis was defined according to the clinical guidelines. Accordingly, we showed that these novel polymeric valves closely mimic AS, and can be a desired cost-saving solution for testing the performance of the transcatheter aortic valve systems in vitro.  相似文献   

12.
In this work, a new mechanical prosthetic heart valve, the central axis valve, is presented. This new prosthesis has been tested in vitro, and compared with four other common prosthetic cardiac valves (Starr-Edwards 6120, Bjork-Shiley monostrut, Medtronic-Hall, and St Jude Medical valves). All valves studied have the same orifice diameter of 22 mm. The prostheses were installed inside a transparent mitral test chamber, which enables pressure drop measurement to be made under steady-state flow conditions using a blood analogue fluid. Pressure drop loss is one important factor affecting the overall performance of a prosthetic heart valve. Steady-state flow tests are essential to predict certain flow characteristics and pressure gradient loss before more complicated, expensive, and difficult-to-interpret pulsatile flow tests are conducted. All experiments were performed in vitro and at steady volumetric flow rates of 10 to 30 l/min. The Starr-Edwards SE 6120 showed the highest values for pressure drop. The St Jude Medical valve offers the minimum resistance to flow. The central axis valve comes second to the Starr-Edwards valve for this type of measurement. The new valve is promising. A complete valve evaluation programme, covering initial conceptional design through to clinical use, is in progress. Materials for the fabrication of the new valve are also under consideration.  相似文献   

13.
The place of balloon dilatation of the aortic valve in the treatment of calcific aortic stenosis is controversial. Thirty two patients (mean age 76) in whom valve replacement was contraindicated were followed up for three to 24 months (mean 8); 25 were in functional class III or IV according to the New York Heart Association''s classification. Major complications of the procedure occurred in four patients. Echocardiography and Doppler studies were performed before operation and before discharge in 28 patients, and the area of the valve was measured again six to 50 (mean 23) weeks after operation in 11 patients. The peak to peak aortic pressure gradient fell from a mean of 65 (SD 24) to 46 (20) mm Hg, but the area of the aortic valve, measured by Doppler echocardiography, in 18 patients showed a modest but significant increase, from 0.61 (0.16) to 0.74 (0.23) cm2. One month after dilatation, 29 patients were alive, of whom 17 had improved symptoms. Only two had lasting clinical benefit. Sixteen patients died, 12 of a cardiac cause. The estimated one year survival rate was 49%. Six patients underwent or required valve replacement because of persisting symptoms. In view of its limited long term efficacy balloon dilatation of the aortic valve should be used only for patients with severe symptoms whose life expectancy is limited by other disease or who are considered to be unsuitable for valve replacement. It may have a role in improving the condition of patients who present with cardiogenic shock or pulmonary oedema before valve replacement is undertaken.  相似文献   

14.
Secondary lymphatic valves are essential for minimizing backflow of lymph and are presumed to gate passively according to the instantaneous trans-valve pressure gradient. We hypothesized that valve gating is also modulated by vessel distention, which could alter leaflet stiffness and coaptation. To test this hypothesis, we devised protocols to measure the small pressure gradients required to open or close lymphatic valves and determine if the gradients varied as a function of vessel diameter. Lymphatic vessels were isolated from rat mesentery, cannulated, and pressurized using a servo-control system. Detection of valve leaflet position simultaneously with diameter and intraluminal pressure changes in two-valve segments revealed the detailed temporal relationships between these parameters during the lymphatic contraction cycle. The timing of valve movements was similar to that of cardiac valves, but only when lymphatic vessel afterload was elevated. The pressure gradients required to open or close a valve were determined in one-valve segments during slow, ramp-wise pressure elevation, either from the input or output side of the valve. Tests were conducted over a wide range of baseline pressures (and thus diameters) in passive vessels as well as in vessels with two levels of imposed tone. Surprisingly, the pressure gradient required for valve closure varied >20-fold (0.1-2.2 cmH(2)O) as a passive vessel progressively distended. Similarly, the pressure gradient required for valve opening varied sixfold with vessel distention. Finally, our functional evidence supports the concept that lymphatic muscle tone exerts an indirect effect on valve gating.  相似文献   

15.
A young male patient, just recovered from a recent transient ischaemic attack, was operated on for mitral valve insufficiency due to suspected endocarditis. Multiple wear-and-tear lesions were found at the line of closure of the mitral valve, which appeared to be Lambl''s excrescences. The valve was replaced.  相似文献   

16.
In this series of studies, the innervation patterns of whole-mount preparations of bicuspid and tricuspid valves were studied by light microscopy in the mouse, rat, guinea pig, and opossum. The acetylcholinesterase-positive networks of nerve fibers showed many similarities in the basic patterns of valve innervation in all of the species studied, but several interspecies variations were observed. The basal zone of the valve adjacent to the fibromuscular atrioventricular ring displayed the most dense plexus of nerves, with acetylcholinesterase-positive fibers being seen across the width of the valve. In the intermediate zone of the valve, less dense plexuses of nerve fibers were found; and these were more numerous in the cuspal areas and less numerous in the intervening commissural areas. In the distal portions of the valve, nerve networks arborized extensively, with some of their nerve fibers extending toward the chordae tendineae and the free edges of the valve cusps. Only in the guinea pig and opossum did these fibers reach the free margin of the valve cusp, where they either ended directly as free nerve endings or lay parallel to the free edge of the cusp, often running between adjacent chordae tendineae. Although the patterns of innervation were similar in both bicuspid and tricuspid valves, the innervation density of the bicuspid valve was greater than that of the tricuspid valve for each species examined. A distinguishing feature of guinea pig and opossum tricuspid valves was that their chordae tendineae were relatively more prominent and more densely innervated than the bicuspid chordae tendineae. Free nerve endings with no light microscopic evidence of specialization were present throughout the bicuspid and tricuspid valves of all species studied. Some nerve endings in the opossum showed evidence of specialization, with brush-like arborizations leading to presumed free terminals seen chiefly in the distal zone of the valve cusps. Although some general tendencies were apparent, we have demonstrated that interspecies heterogeneity exists in the terminal networks of the atrioventricular valves of mouse, rat, guinea pig, and opossum.  相似文献   

17.
A precise mixture of extracellular matrix (ECM) secreted by valvular cells forms a scaffold that lends the heart valve the exact mechanical and tensile strength needed for accurate hemodynamic performance. ECM proteins are a key component of valvular endothelial cell (VEC)-valvular interstitial cell (VIC) communication essential for maintenance of the valve structure. This study reports the healthy adult pulmonary and aortic valve proteomes characterized by LC-MS/MS, resulting in 2710 proteins expressed by 1513 genes, including over 300 abundant ECM proteins. Surprisingly, this study defines a distinct proteome for each semilunar valve. Protein-protein networking (PPN) was used as a tool to direct selection of proteomic candidates for biological investigation. Local PPN for nidogen 1 (Nid1), biglycan (Bgn), elastin microfibril interface-located protein 1 (Emilin-1), and milk fat globule-EGF factor 8 protein (Mfge8) were enriched with proteins essential to valve function and produced biological functions highly relevant to valve biology. Immunofluorescent investigations demonstrated that these proteins are functionally distributed within the pulmonary and aortic valve structure, indicative of important contribution to valve function. This study yields new insight into protein expression contributing to valvular maintenance and health and provides a platform for unbiased assessment of protein alterations during disease processes.  相似文献   

18.
BACKGROUND: Many diseases that affect the mitral valve are accompanied by the proliferation or degradation of tissue microstructure. The early acoustic detection of these changes may lead to the better management of mitral valve disease. In this study, we examine the nonstationary acoustic effects of perturbing material parameters that characterize mitral valve tissue in terms of its microstructural components. Specifically, we examine the influence of the volume fraction, stiffness and splay of collagen fibers as well as the stiffness of the nonlinear matrix in which they are embedded. METHODS AND RESULTS: To model the transient vibrations of the mitral valve apparatus bathed in a blood medium, we have constructed a dynamic nonlinear fluid-coupled finite element model of the valve leaflets and chordae tendinae. The material behavior for the leaflets is based on an experimentally derived structural constitutive equation. The gross movement and small-scale acoustic vibrations of the valvular structures result from the application of physiologic pressure loads. Material changes that preserved the anisotropy of the valve leaflets were found to preserve valvular function. By contrast, material changes that altered the anisotropy of the valve were found to profoundly alter valvular function. These changes were manifest in the acoustic signatures of the valve closure sounds. Abnormally, stiffened valves closed more slowly and were accompanied by lower peak frequencies. CONCLUSION: The relationship between stiffness and frequency, though never documented in a native mitral valve, has been an axiom of heart sounds research. We find that the relationship is more subtle and that increases in stiffness may lead to either increases or decreases in peak frequency depending on their relationship to valvular function.  相似文献   

19.

Background

Failure of bioprosthetics is usually caused by calcification of the leaflets as a consequence of high tensile stresses. The stentless valve resembles native mitral valve anatomy, has a flexible leaflet attachment and a suspension at the papillary muscles, and preserves annuloventricular continuity. In this study, the effects of the stentless valve design on leaflet stress were investigated with a finite element model.

Methods

Finite element models of the stentless quadrileaflet mitral valve were created in the close and open configurations. The geometry of the stented trileaflet mitral valve was also analyzed for comparative purposes. Under the designated pressures, the regional stresses were evaluated, and the distributions of stresses were assessed.

Results

Regardless of whether the valve is in the open or close configuration, the maximum first principal stress was significantly lower in the stentless valve than in the stented valve. For the stentless valves, limited stress concentration was discretely distributed in the papillary flaps under both close and open conditions. In contrast, in the stented valve, increased stress concentration was evident at the central belly under the open condition and at the commissural attachment under close condition. In either configuration, the maximum second principal stress was markedly lower in the stentless valve than in the stented valve.

Conclusions

The stentless valve was associated with a significant reduction in leaflet stress and a more homogeneous stress distribution compared to the stented valve. These findings are consistent with recent reports of the clinical effectiveness of the stentless quadrileaflet mitral valve.  相似文献   

20.
The dimensions of the aortic valve components condition its ability to prevent blood from flowing back into the heart. While the theoretical parameters for best trileaflet valve performance have already been established, an effective approach to describe other less optimal, but functional models has been lacking. Our goal was to establish a method to determine by how much the dimensions of the aortic valve components can vary while still maintaining proper function. Measurements were made on silicone rubber casts of human aortic valves to document the range of dimensional variability encountered in normal adult valves. Analytical equations were written to describe a fully three-dimensional geometric model of a trileaflet valve in both the open and closed positions. A complete set of analytical, numerical and graphical tools was developed to explore a range of component dimensions within functional aortic valves. A list of geometric guidelines was established to ensure safe operation of the valve during the cardiac cycle, with practical safety margins. The geometry-based model presented here allows determining quickly if a certain set of valve component dimensions results in a functional valve. This is of great interest to designers of new prosthetic heart valve models, as well as to surgeons involved in valve-sparing surgery.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号