首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The design of an electrochemical glucose sensing device formed by the electrodeposition of multifunctional Au nanoparticles is reported here as a novel concept for an enhanced generic sensing platform. Initially gold nanoparticles (Au) were alternatively coated with a layer of positively charged redox polymer (ORP) and a negatively charged glucose oxidase (GOX) layer alternatively using layer-by-layer methodology to form multifunctional Au/ORP/GOX/ORP particles. The modification and stability of the Au nanoparticles was monitored by using UV-vis spectroscopy and zeta-potential measurements. The modified Au nanoparticles were electrophoretically deposited onto an electrode to produce an electrochemical glucose sensing device. A considerable influence of electrophoretic deposition time and potential was found on the sensing platform response. Preliminary responses to glucose addition showed an enhanced performance by applying an electrophoretic deposition potential of +1.2V vs. Ag/AgCl for 30min. The observed response in the case of microelectrode geometry was in the range of mAcm(2). This work also shows that the presence of a second outer ORP layer on the functionalised Au nanoparticles improved the response.  相似文献   

2.
A novel label-free electrochemical aptasensor based on graphene-polyaniline (GR-PANI) nanocomposites film for dopamine (DA) determination was reported. The resulting GR-PANI layer exhibited good current response for DA determination. The good electron transfer activity might be attributed to the effect of GR and PANI. The highly conductive and biocompatible nanostructure of GR-PANI nanocomposites was characterized by scanning electron microscopy (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). To quantify the amount of DA, the peaks of square-wave voltammetry (SWV) were monitored using the redox couple of an [Fe(CN)(6)](4-/3-) probe. The electrochemical aptasensor showed a linear response to DA in the range 0.007-90 nmol/L and a limit of detection of 0.00198 nmol/L (S/N=3). The electrochemical aptasensor was successfully tested on human serum samples.  相似文献   

3.
A portable amperometric potentiostat was designed and implemented in this work. It was developed to acquisit the current signals produced from bilirubin by an electrochemical sensor. Based on an SOC-based chip, this potentiostat has the merits of moderate accuracy, small size, low cost, and high portability. The bilirubin electrode was prepared by synthesizing a thin layer of bilirubin imprinted poly(methacrylic acid-co-ethylene glycol dimethacrylate) onto the Au layer. With the molecularly imprinted polymer (MIP) film, specific detection of bilirubin was successfully achieved. The cyclic voltammogram of the electrode was measured from this assembled potentiostat. The performance from a commercial potentiostat was considered rather stable and was used as a reference to examine and evaluate the performance of the assembled potentiostat. The detected current signals by the bilirubin sensing were obtained. Linear calibration with a sensitivity of 1.344+/-0.38 microA/mg dl was achieved. Our experimental results showed that the proposed potentiostat's performance could achieve sufficient performance. The evaluation was also made from the aspects such as reset time and steady-response time. The self-assembled potentiostat thus demonstrated its ability in precise detection of bilirubin from an electrode layered with the imprinted polymer film.  相似文献   

4.
The catalytic growth of Au nanoparticles (AuNPs) has been employed in several analytical methods for improving the detection sensitivity, or integrated with the enzyme reactions for the quantitative detection of the respective substrates. However, the catalytic growth of Au nanoparticles do not work in some situations, such as surface plasmon resonance (SPR), electrochemistry, where metal matrices were used, because metal matrices used in these techniques, e.g. Au, are susceptible to metal deposition, which increased the background seriously. In this work, a SiO(2) layer was vapor-deposited on the gold film. The inhibition of metal deposition by this SiO(2) layer was investigated by SPR sensor. The results showed that the SiO(2) layer could avoid the deposition of metal on Au film. With the low background achieved by SiO(2)-coated Au films, sensitive detection of DNA hybridization using the catalytic growth of Au nanoparticles enhanced SPR was demonstrated. The work described here maybe helpful for the development of sensitive bioanalytical methods.  相似文献   

5.
A novel label-free immunosensing strategy for sensitive detection of tumor necrosis factor-alpha antigen (TNF-α) via surface-initiated atom transfer radical polymerization (SI-ATRP) was proposed. In this strategy, the Au electrode was first modified by consecutive SI-ATRP of ferrocenylmethyl methacrylate (FMMA) and glycidyl methacrylate (GMA), and TNF-α antibody was coupled to the copolymer segment of GMA (PGMA) by aqueous carbodiimide coupling reaction. Subsequently, the target TNF-α antigen was captured onto the Au electrode surface through immunoreaction. The whole process was confirmed by scanning electron microscopy (SEM) and surface plasmon resonance (SPR) measurements. With introduction of redox polymer segment of FMMA (PFMMA) as electron-transfer mediator, the antigen-coupled Au electrode exhibited well electrochemical behavior, as revealed by cyclic voltammetry measurement. This provided a sensing platform for sensitive detection of TNF-α with a low detection limit of 3.9pgmL(-1). Furthermore, the "living" characteristics of the ATRP process can not only be readily controlled but also allow further surface functionalization of the electrodes, thus the proposed method presented a way for label-free and flexible detection of biomolecules.  相似文献   

6.
Su Z  Liu Y  Xie Q  Chen L  Zhang Y  Meng Y  Li Y  Fu Y  Ma M  Yao S 《Biosensors & bioelectronics》2012,36(1):154-160
We report on the thiol-ene chemistry guided preparation of novel thiolated polymeric nanocomposite films of abundant anionic carboxylic groups for electrostatic enrichment and sensitive electroanalysis of cationic dopamine (DA) in neutral solution. Briefly, the thiol-ene nucleophilic reaction of a carboxylated thiol with oxidized polypyrrole (PPy), which was electrosynthesized on an Au electrode in the presence of solution-dispersed acidified multiwalled carbon nanotubes (MWCNTs), produced an a PPy-thiol-MWCNTs/Au electrode, and the PPy can be electrochemically overoxidized (OPPy) to form an OPPy-thiol-MWCNTs/Au electrode. The carboxylic groups of the polymeric nanocomposite film originate from the acidified MWCNTs, PPy-tethered carboxylated thiol, and OPPy. The carboxylated thiols examined are mercaptosuccinic acid (MSA) and thioglycolic acid, with β-mercaptoethanol as a control. Electrochemical quartz crystal microbalance, scanning electron microscopy, Fourier transform infrared spectroscopy and ultraviolet-visible spectroscopy were used for film characterization and process monitoring. Under the optimized condition, the differential pulse voltammetry peak current of DA oxidation at OPPy-MSA-MWCNTs/Au electrode is linear with DA concentration from 1.00×10(-9) to 2.87×10(-6) mol L(-1), with a limit of detection of 0.4 nmol L(-1), good anti-interferent ability and stability.  相似文献   

7.
A novel core-shell composite of gold nanoparticles (AuNPs) and SiO(2) molecularly imprinted polymers (AuNPs@SiO(2)-MIPs) was synthesized through sol-gel technique and applied as a molecular recognition element to construct an electrochemical sensor for determination of dopamine (DA). Compared with previous imprinting recognition, the main advantages of this strategy lie in the introduction and combination of AuNPs and biocompatible porous sol-gel material (SiO(2)). The template molecules (DA) were firstly adsorbed at the AuNPs surface due to their excellent affinity, and subsequently they were further assembled onto the polymer membrane through hydrogen bonds and π-π interactions formed between template molecules and silane monomers. Cyclic voltammetry (CV) was carried out to extract DA molecules from the imprinted membrane, and as a result, DA could be rapidly and effectively removed. The AuNPs@SiO(2)-MIPs was characterized by ultraviolet visible (UV-vis) absorbance spectroscopy, transmission electron microscope (TEM) and Fourier transform infrared spectrometer (FT-IR). The prepared AuNPs@SiO(2)-MIPs sensor exhibited not only high selectivity toward DA in comparison to other interferents, but also a wide linear range over DA concentration from 4.8×10(-8) to 5.0×10(-5)M with a detection limit of 2.0×10(-8)M (S/N=3). Moreover, the new electrochemical sensor was successfully applied to the DA detection in dopamine hydrochloride injection and human urine sample, which proved that it was a versatile sensing tool for the selective detection of DA in real samples.  相似文献   

8.
Cai H  Zhu N  Jiang Y  He P  Fang Y 《Biosensors & bioelectronics》2003,18(11):1311-1319
Synthesis of the novel Cu@Au alloy nanoparticle and its application in an electrochemical DNA hybridization detection assay is described in this article. We report a low-temperature method for generating core-shell particles consisting of a core of Cu and a thin layer of Au shell that can be readily functionalized with oligonucleotides. Core-shell Cu@Au particles were successfully labeled to a 5'-alkanethiol capped oligonucleotides probe that is related to the colitoxin gene. The DNA genetic sensing assay relies on the electrostatic adsorption of target oligonucleotides onto conducting polypyrrole (PPy) surface at the glassy carbon electrode (GCE), and its hybridization to the alloy particle-oligonucleotides DNA probe. Hybridization events between probe and target were monitored by the release of the copper metal atoms anchored on the hybrids by oxidative metal dissolution and the indirectly determination of the solubilized Cu2+ ions by sensitive anodic stripping voltammetry (ASV). The detection limit is 5.0 pmol l(-1) of target oligonucleotides. The Cu@Au core-shell nanoparticles combining the surface modification properties of Au with the good electrochemical activity of Cu core shows their perspective application in the electrochemical DNA hybridization analysis assay.  相似文献   

9.
Lu L  Liu B  Zhao Z  Ma C  Luo P  Liu C  Xie G 《Biosensors & bioelectronics》2012,33(1):216-221
A novel electrochemical immunoassay system for the detection of human epididymis-specific protein 4 (HE4) was developed. A chitosan-titanium carbide (TiC) nanocomposition film was first electrodeposited onto a tin-doped indium oxide (ITO) electrode at a constant potential. Gold (Au) nanoparticles were then electrodeposited on the surface of the chitosan-TiC film by cyclic voltammetry (CV). The capture antibody (anti-HE4) was adsorbed onto the Au and TiC nanoparticles. After a specific sandwich immunoreaction among the capture antibody, HE4, and biotinylated secondary antibody, biotinylated primer DNA was immobilized on the secondary antibody by biotin-streptavidin system. Appropriate amounts of circular template DNA and biotinylated primer DNA were used for rolling circle amplification (RCA) under optimal conditions. The RCA products provided a large number of sites to link DNA detection probes. Doxorubicin hydrochloride intercalated the CG-GC steps between the RCA products and the DNA detection probes, which was monitored by differential pulse voltammetry (DPV) based on the current signal of doxorubicin hydrochloride. With the above-mentioned amplification factors, the current responded to HE4 linearly in the concentration range of 3-300 pM under optimal detection conditions, with a detection limit of 0.06 pM. Stepwise changes in the microscopic features of the surfaces and electrochemical properties upon the formation of each layer were confirmed by scanning electron microscopy (SEM), atomic force microscopy (AFM), and electrochemical impedance spectroscopy (EIS). This system was successfully employed for the detection of HE4 with good accuracy and renewable ability.  相似文献   

10.
Surface plasmons (SPs), the coherent charge density oscillations of the electrons bound to the metal-dielectric interface, are dominating the research field of optics. One of the ubiquitous applications of SPs is in sensing. In the present work, we have theoretically studied a couple of surface plasmon resonance (SPR)-based fiber-coupled ultra-sensitive refractive index sensors working in the infrared (IR) region. Either of the copper (Cu) and aluminum (Al) is used as surface plasmon exciting layers in these sensing probes. On the top of the metal layer, field-enhancing graphene and silicon layers are considered. The probes are characterized in terms of sensitivity and detection accuracy (DA). The sensitivities of Cu- and Al-based optimized probes are obtained respectively to be 23.50 and 24 μm/refractive index unit (RIU). To ensure the probes’ compatibility with bio-samples, an extra bio-recognition layer of graphene has been considered over the silicon layer which resulted into the respective sensitivities of 20 and 19.50 μm/RIU for Cu- and Al-based probes with appreciably good DAs.  相似文献   

11.
Nitrogen doped graphene (NG) was prepared by thermally annealing graphite oxide and melamine mixture. After characterization by atomic force microscopy and X-ray photoelectron spectroscopy etc., the electrochemical sensor based on NG was constructed to simultaneously determine small biomolecules such as ascorbic acid (AA), dopamine (DA) and uric acid (UA). Due to its unique structure and properties originating from nitrogen doping, NG shows highly electrocatalytic activity towards the oxidation of AA, DA and UA. The electrochemical sensor shows a wide linear response for AA, DA and UA in the concentration range of 5.0×10(-6) to 1.3×10(-3)M, 5.0×10(-7) to 1.7×10(-4)M and 1.0×10(-7) to 2.0×10(-5)M with detection limit of 2.2×10(-6)M, 2.5×10(-7)M and 4.5×10(-8)M at S/N=3, respectively. These results demonstrate that NG is a promising candidate of advanced electrode material in electrochemical sensing and other electrocatalytic applications.  相似文献   

12.
In this paper, we report a novel wavelength interrogation-based surface plasmon resonance (SPR) system, in which a film of three Ag layers and three Au layers are alternately deposited on a Kretschmann configuration as sensing element. This multilayer film shows higher sensitivity for refractive index (RI) measurement by comparing with single Au layer structure, which is consistent with its theoretical calculation. A sensitivity range of 2056–5893 nm/RIU can be achieved, which is comparable to RI sensitivities of other wavelength-modulated SPR sensors. Compared with Ag film, this Ag/Au multilayer arrangement offers anti-oxidant protection. This SPR biosensor based on a cost-effective Ag/Au multilayer structure is applicable to the real-time detection of specific interactions and dissociation of low protein concentrations. To extend the application of this highly-sensitive metal film device, we integrated this concept on an optical fiber. The range of RI sensitivities with Ag/Au multilayer was 1847–3309 nm/RIU. This miniaturized Ag/Au multilayer-based fiber optic sensor has a broad application in chemical and biological sensing.  相似文献   

13.
A novel composite of graphene sheets/Congo red-molecular imprinted polymers (GSCR-MIPs) was synthesized through free radical polymerization (FRP) and applied as a molecular recognition element to construct dopamine (DA) electrochemical sensor. The template molecules (DA) were firstly absorbed at the GSCR surface due to their excellent affinity, and subsequently, selective copolymerization of methacrylic acid (MAA) and ethylene glycol dimethacrylate (EGDMA) was further achieved at the GSCR surface. Potential scanning was presented to extract DA molecules from the imprinted polymers film, and as a result, DA could be rapidly and completely removed by this way. With regard to the traditional MIPs, the GSCR-MIPs not only possessed a faster desorption and adsorption dynamics, but also exhibited a higher selectivity and binding capacity toward DA molecule. As a consequence, an electrochemical sensor for highly sensitive and selective detection of DA was successfully constructed as demonstration based on the synthesized GSCR-MIPs nanocomposites. Under experimental conditions, selective detection of DA in a linear concentration range of 1.0 × 10(-7)-8.3 × 10(-4)M was obtained, which revealed a lower limit of detection and wider linear response compared to some previously reported DA electrochemical MIPs sensors. The new DA electrochemical sensor based on GSCR-MIPs composites also exhibited excellent repeatability, which expressed as relative standard deviation (RSD) was about 2.50% for 30 repeated analyses of 20 μM DA.  相似文献   

14.
Here, an ultrasensitive label-free electrochemical aptasensor was developed for dopamine (DA) detection. Construction of the aptasensor was carried out by electrodeposition of gold–platinum nanoparticles (Au–PtNPs) on glassy carbon (GC) electrode modified with acid-oxidized carbon nanotubes (CNTs–COOH). A designed complementary amine-capped capture probe (ssDNA1) was immobilized at the surface of PtNPs/CNTs–COOH/GC electrode through the covalent amide bonds formed by the carboxyl groups on the nanotubes and the amino groups on the oligonucleotides. DA-specific aptamer was attached onto the electrode surface through hybridization with the ssDNA1. Methylene blue (MB) was used as an electrochemical indicator that was intercalated into the aptamer through the specific interaction with its guanine bases. In the presence of DA, the interaction between aptamer and DA displaced the MB from the electrode surface, rendering a lowered electrochemical signal attributed to a decreased amount of adsorbed MB. This phenomenon can be applied for DA detection. The peak current of probe (MB) linearly decreased over a DA concentration range of 1–30 nM with a detection limit of 0.22 nM.  相似文献   

15.
A surface acoustic wave sensor operating at 104 MHz and functionalized with a polypyrrole molecularly imprinted polymer has been designed for selective detection of dopamine (DA). Optimization of pyrrole/DA ratio, polymerization and immersion times permitted to obtain a highly selective sensor, which has a sensitivity of 0.55°/mM (≈550 Hz/mM) and a detection limit of ≈ 10 nM. Morphology and related roughness parameters of molecularly imprinted polymer surfaces, before and after extraction of DA, as well as that of the non imprinted polymer were characterized by atomic force microscopy. The developed chemosensor selectively recognized dopamine over the structurally similar compound 4‐hydroxyphenethylamine (referred as tyramine), or ascorbic acid,which co‐exists with DA in body fluids at a much higher concentration. Selectivity tests were also carried out with dihydroxybenzene, for which an unexpected phase variation of order of 75% of the DA one was observed. Quantum chemical calculations, based on the density functional theory, were carried out to determine the nature of interactions between each analyte and the PPy matrix and the DA imprinted PPy polypyrrole sensing layer in order to account for the important phase variation observed during dihydroxybenzene injection. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

16.
This paper presents an electrochemical immune sensor for label free detection of epidermal growth factor receptor (EGFR) by immobilizing anti-EGFR antibody (Anti-EGFRab) on dithiobissuccinimidyl propionate (DTSP) self-assembled monolayer (SAM) on gold (Au) electrode. Electrochemical studies show that increased surface concentration of redox moieties onto Anti-EGFRab/DTSP immuno-electrode leads to high electron transport and improved sensing performance. The antigen-antibody complex demonstrates a high association constant (5×10(12)L/mol) that results in high affinity of Anti-EGFRab to EGFR, confirming that the DTSP-SAM provides a conducive environment for anti-EGFR immobilization. The electrochemical response of EA/Anti-EGFRab/DTSP/Au electrode as a function of EGFR concentrations exhibits a linear range from 1pg/mL to 100ng/mL, a detection limit of 1pg/mL at a sensitivity of 2.02μAM(-1)at a regression coefficient of 0.99.  相似文献   

17.
Here, we report a sensitive amplified electrochemical impedimetric aptasensor for thrombin, a kind of serine protease that plays important role in thrombosis and haemostasis. For improving detection sensitivity, a sandwich sensing platform is fabricated, in which the thiolated aptamers are firstly immobilized on a gold substrate to capture the thrombin molecules, and then the aptamer functionalized Au nanoparticles (AuNPs) are used to amplify the impedimetric signals. Such designed aptamer/thrombin/AuNPs sensing system could not only improve the detection sensitivity compared to the reported impedimetric aptasensors but also provide a promising signal amplified model for aptamer-based protein detection. In this paper, we realize a sensitive detection limit of 0.02 nM, with a linear range of 0.05-18 nM. Meanwhile, the effect of 6-mercaptohexanol (MCH) and 2-mercaptoethanol (MCE) on the modification of the electrode is investigated.  相似文献   

18.
Ji S  Guo Q  Yue Q  Wang L  Wang H  Zhao J  Dong R  Liu J  Jia J 《Biosensors & bioelectronics》2011,26(5):2067-2073
Fabrication of sub-monolayer array of Pt nanoparticles (PtNPs) assembled at nucleobases terminated layers and their application into H(2)O(2) and glucose sensing were reported. To prepare such a PtNPs assembly, 3-mercaptopropionic acid (MPA), Zr(4+), nucleotide-5'-monophosphate (NTMP including guanosine, adenosine, cytidine, uridine-5'-monophosphate, and abbreviations were GMP, AMP, CMP, UMP, respectively) were adsorbed onto Au substrate sequentially to form nucleobases terminated surface and Zr(4+) acted as binder to link carboxylic and phosphoric groups (NTMP/Zr(4+)/MPA/Au). Complexation of cisplatin, cis-Pt(NH(3))(2)Cl(2), with terminated nucleobases and following electrochemical reduction of surface-bound cisplatin gave PtNPs attached surface. Different PtNPs coverage or particle density was obtained depending on the NTMP used and decreased in the order: PtNPs/GMP/Zr(4+)/MPA/Au>PtNPs/AMP/Zr(4+)/MPA/Au>PtNPs/CMP/Zr(4+)/MPA/Au>PtNPs/UMP/Zr(4+)/MPA/Au. The surface loading of Pt was between 160 and 16 ng/cm(2). The as prepared PtNPs can be used as electrocatalysts for H(2)O(2) sensing (detection limit of H(2)O(2)<100 nM) and the sensitivity increased with decreasing PtNPs density. After adsorption of glucose oxidase, the modified electrode can be used as enzymatic electrode for glucose sensing and a detection limit of 38.5 μM was achieved. This study provided an example of fabricating PtNP arrays utilising surface complexation of cisplatin with nucleobases. The advantage of this method is that the NP density can be controlled through changing nucleobases or Pt complexes used to obtain suitable kinetics of the complexation reactions. Additionally, the PtNPs sub-monolayer as prepared has high sensitivity for H(2)O(2) sensing even at a very low loading of Pt.  相似文献   

19.
In this study, electrical impedimetric biosensors composed of Au-electrodes were fabricated for the quantitative detection of human serum albumin (HSA), an essential biomarker of liver function. The Au-electrodes were fabricated via a single-step photolithography process, and can be easily integrated in biochips for assessing liver function in the future. The glass sensing surface between two adjacent Au-electrodes was modified with 3-aminopropyltriethoxysilane (APTES) to improve the biocompatibility for its subsequent binding to anti-human serum albumin (AHSA). The sensing surface without AHSA binding was blocked using skim milk powders, preventing possible non-specific bonding HSA conjugation. Biosensors were used to measure HSA concentration for liver function detection. The impedance between two adjacent Au-electrodes of the biosensors applied with various HSA concentrations was directly measured, and quantified using an electrochemical impedance spectroscopy system under AC conditions. The results of plotting both values in log scales indicated the impedance increased linearly with HSA conjugation increase. The limit of HSA detection was about 2'10(-4)mg/ml using the electrochemical impedimetric biosensor proposed in this work. This study demonstrates the feasibility of using electrochemical impedimetry as a bio-sensing mechanism to quantify human serum albumin concentration. The sensor proposed in this work also displays great potential for assessing liver function because of its simple detection mechanism, ease of biochip integration, and low cost.  相似文献   

20.
A poly(3-methylthiophene) modified glassy carbon electrode coated with Nafion/single-walled carbon nanotubes film was fabricated and used for highly selective and sensitive determination of dopamine. The hybrid film surface of the modified electrode was characterized by scanning electrochemical microscopy (SECM) and the results indicated that the carbon nanotubes were dispersed uniformly on the conductive polymer. The experimental results suggest that the hybrid film modified electrode combining the advantages of poly(3-methylthiophene), carbon nanotubes with Nafion exhibits dramatic electrocatalytic effect on the oxidation of dopamine (DA) and results in a marked enhancement of the current response. In 0.1M phosphate buffer solution (PBS) of pH 7.0, the differential pulse voltammetric (DPV) peak heights are linear with DA concentration in three intervals, viz. 0.020-0.10 microM, 0.10-1.0 microM and 1.0-6.0 microM, with correlation coefficients of 0.9993, 0.9996 and 0.9993, respectively. The detection limit of 5.0 nM DA could be estimated (S/N=3). Moreover, the interferences of ascorbic acid (AA) and uric acid (UC) are effectively diminished. This hybrid film modified electrode can be applied to the determination of DA contents in dopamine hydrochloride injection and human serum. These attractive features provide a potential application for either in vitro measurement of DA in the presence of excess AA and UA or as detectors in flow injection analysis (FIA) and high performance liquid chromatography (HPLC).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号