首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The purpose of this study was to develop a detection method for viable E. coli O157:H7 in fresh produce and recreational water. The method was evaluated using eight samples of produce wash and recreational water with or without spiked E. coli O157:H7 at ≤ 102 CFU·ml− 1 and concentrated using dead-end ultrafiltration (DEUF) to produce primary and secondary retentates. Fifty-four matrix replicates of undiluted secondary retentates or dilutions (1:2 or 1:10 in buffer) were evaluated using an IMS/ATP bioluminescence assay (IMS/ATP). Combining primary and secondary DEUF yielded a 2-4 log10 increase in E. coli O157:H7 concentrations in spiked samples and resulted in signal-to-noise ratios 2-219 fold higher than controls, depending on the sample type. DEUF increased the concentration of E. coli O157:H7 to within the detectable limits of IMS/ATP. The combined assay provided detection of viable E. coli O157:H7 in produce and recreational water. Accurate detection of microbial pathogens using DEUF and IMS/ATP could reduce disease outbreaks from contaminated water sources and food products.  相似文献   

2.
Presumptive identification of Escherichia coli O157:H7 is possible in an individual, nonmultiplexed PCR if the reaction targets the enterohemorrhagic E. coli (EHEC) eaeA gene. In this report, we describe the development and evaluation of the sensitivity and specificity of a PCR-based 5′ nuclease assay for presumptively detecting E. coli O157:H7 DNA. The specificity of the eaeA-based 5′ nuclease assay system was sufficient to correctly identify all E. coli O157:H7 strains evaluated, mirroring the previously described specificity of the PCR primers. The SZ-primed, eaeA-targeted 5′ nuclease detection assay was capable of rapid, semiautomated, presumptive detection of E. coli O157:H7 when ≥103 CFU/ml was present in modified tryptic soy broth (mTSB) or modified E. coli broth and when ≥104 CFU/ml was present in ground beef-mTSB mixtures. Incorporating an immunomagnetic separation (IMS) step, followed by a secondary enrichment culturing step and DNA recovery with a QIAamp tissue kit (Qiagen), improved the detection threshold to ≥102 CFU/ml. Surprisingly, immediately after IMS, the sensitivity of culturing on sorbitol MacConkey agar containing cefeximine and tellurite (CT-SMAC) was such that identifiable colonies were demonstrated only when ≥104 CFU/ml was present in the sample. Several factors that might be involved in creating these false-negative CT-SMAC culture results are discussed. The SZ-primed, eaeA-targeted 5′ nuclease detection system demonstrated that it can be integrated readily into standard culturing procedures and that the assay can be useful as a rapid, automatable process for the presumptive identification of E. coli O157:H7 in ground beef and potentially in other food and environmental samples.  相似文献   

3.
Escherichia coli O157:H7 is an important pathogenic Bacterium that threatens human health. A convenient, sensitive and specific method for the E. coli O157:H7 detection is necessary. We developed two pairs of monoclonal antibodies through traditional hybridoma technology, one specifically against E. coli O157 antigen and the other specifically against E. coli H7 antigen. Using these two pairs of antibodies, we developed two rapid test kits to specifically detect E. coli O157 antigen and E. coli H7 antigen, respectively. The detection sensitivity for O157 positive E. coli is 1 × 103 CFU per ml and for H7 positive E. coli is 1 × 104 CFU per ml. Combining these two pairs of antibodies together, we developed a combo test strip that can specifically detect O157: H7, with a detection sensitivity of 1 × 104 CFU per ml, when two detection lines are visible to the naked eye. This is currently the only rapid detection reagent that specifically detects O157: H7 by simultaneously detecting O157 antigen and H7 antigens of E. coli. Our product has advantages of simplicity and precision, and can be a very useful on-site inspection tool for accurate and rapid detection of E. coli O157:H7 infection.  相似文献   

4.
Surface water and groundwater are continuously used as sources of drinking water in many metropolitan areas of the United States. The quality of water from these sources may be reduced due to increases in contaminants such as Escherichia coli from urban and agricultural runoffs. In this study, a multiplex fluorogenic PCR assay was used to quantify E. coli O157:H7 in soil, manure, cow and calf feces, and dairy wastewater in an artificial wetland. Primers and probes were designed to amplify and quantify the Shiga-like toxin 1 (stx1) and 2 (stx2) genes and the intimin (eae) gene of E. coli O157:H7 in a single reaction. Primer specificity was confirmed with DNA from 33 E. coli O157:H7 and related strains with and without the three genes. A direct correlation was determined between the fluorescence threshold cycle (CT) and the starting quantity of E. coli O157:H7 DNA. A similar correlation was observed between the CT and number of CFU per milliliter used in the PCR assay. A detection limit of 7.9 × 10−5 pg of E. coli O157:H7 DNA ml−1 equivalent to approximately 6.4 × 103 CFU of E. coli O157:H7 ml−1 based on plate counts was determined. Quantification of E. coli O157:H7 in soil, manure, feces, and wastewater was possible when cell numbers were ≥3.5 × 104 CFU g−1. E. coli O157:H7 levels detected in wetland samples decreased by about 2 logs between wetland influents and effluents. The detection limit of the assay in soil was improved to less than 10 CFU g−1 with a 16-h enrichment. These results indicate that the developed PCR assay is suitable for quantitative determination of E. coli O157:H7 in environmental samples and represents a considerable advancement in pathogen quantification in different ecosystems.  相似文献   

5.
Shiga toxin (Stx)-producing Escherichia coli (STEC) are important causes of diarrhoea and the haemolytic uremic syndrome (HUS). The most common STEC serotype implicated worldwide is E. coli O157:H7 that is diagnosed using procedures based on its typical phenotypic feature, the lack of sorbitol fermentation. In addition to E. coli O157:H7, a variety of non-O157:H7 STEC strains that usually ferment sorbitol and are thus missed by using the diagnostic protocol for E.coli O157:H7 have been isolated from patients. Among these sorbitol-fermenting (SF) non-O157:H7 STEC, SF E. coli O157:H and non-O157 STEC strains of serogroups O26, O103, O111 and O145 have emerged as significant causes of HUS and diarrhoea in continental Europe and have been associated with human disease in other parts of the world. Microbiological diagnosis of non-O157:H7 STEC strains is difficult due to their serotype diversity and the absence of a simple biochemical property that distinguishes such strains from the physiological intestinal microflora. Screening for non-O157:H7 STEC and their isolation from stools is presently based on the detection of Stx production or stx genes that are common characteristics of such strains. Molecular subtyping of the most frequent non-O157 STEC demonstrated that strains of serogroups O26, O103 and O111 belong to their own clonal lineages and show unique virulence profiles. SF STEC O157:H strains that have been isolated mostly in Central Europe represent a new clone within E. coli O157 serogroup which has its own typical combination of virulence factors. This revised version was published online in November 2006 with corrections to the Cover Date.  相似文献   

6.
7.
Monoclonal antibodies (MCAs) to the E. coli O157: H7 O-antigen characterized by a high level of activity and specificity have been obtained. We investigated their biochemical properties and diagnostic importance. Based on these results, we constructed a latex assay using monoclonal antibodies for the identification of enterohemorrhagic E. coli belonging to the O157 serogroup. This assay was tested on pure cultures of 31 strains of closely related and other microorganisms. The designed assay allows one to detect microbial cells of E. coli O157:H7 at concentrations of 2.5 × 105 cell/ml and higher.  相似文献   

8.
Escherichia coli O157:H7, a major foodborne pathogen, has been associated with numerous cases of foodborne illnesses. Rapid methods have been developed for the screening of this pathogen in foods in order to circumvent timely plate culture techniques. Unfortunately, many rapid methods are presumptive and do not claim to confirm the presence of E. coli O157:H7. The previously developed method, enzyme-linked immunomagnetic chemiluminescence (ELIMCL), has been improved upon to allow for fewer incidences of false positives when used to detect E. coli O157:H7 in the presence of mixed cultures. The key feature of this assay is that it combines the highly selective synergism of both anti-O157 and anti-H7 antibodies in the sandwich immunoassay format. This work presents application of a newly semi-automated version of ELIMCL to the detection of E. coli O157:H7 in pristine buffered saline yielding detection limits of approximately 1 × 105 to 1 × 106 of live cells/mL. ELIMCL was further demonstrated to detect E. coli O157:H7 inoculated into artificially contaminated ground beef at ca. 400 CFU/g after a 5 h enrichment and about 1.5 h assay time for a total detection time of about 6.5 h. Finally, ELIMCL was compared with USFDA's Bacteriological Analytical Manual method for E. coli O157:H7 in a double-blind study. Using McNemar's treatment, the two methods were determined to be statistically similar for the detection of E. coli O157:H7 in ground beef inoculated with mixed cultures of select bacteria.  相似文献   

9.
To assess the sensitivity of direct plating of bovine fecal samples for detection of Escherichia coli O157:H7, calves (n = 28) were orally inoculated with 109 colony-forming units (cfu) per calf of a mixture of three strains of nalidixic acid-resistant E. coli O157:H7, and fecal samples were collected for analysis. One-gram samples from inoculated calves were mixed with 9 mL of Gram-negative broth with vancomycin, cefixime, and cefsoludin. From this suspension, serial dilutions were made (10−1 to 10−4) and spread plated in triplicate on Sorbitol MacConkey agar with nalidixic acid for enumeration of E. coli O157:H7 in fecal samples. Direct plating samples were streaked for isolation on Sorbitol MacConkey agar with cefixime, and tellurite (SMACct). After incubation overnight at 37°C, morphologically typical colonies from direct streak plates were plated onto blood agar and incubated overnight at 37°C; then an indole test was performed on each colony. Indole-positive colonies were confirmed by O157 agglutination and were then plated on SMAC agar with 20 μg/mL nalidixic acid (SMACnal) to confirm nalidixic acid resistance. Overall sensitivity of detection was 32.5% (110/338 samples). Sensitivity to detect fecal samples shedding at above 5 × 104 cfu/g was 83% (71/86 samples). Based on these data, direct plating of fecal samples might be an effective way to identify cattle that are likely to be shedding E. coli O157 at high levels.  相似文献   

10.
A quantitative competitive PCR (QC-PCR) assay was developed to detect and quantify Escherichia coli O157:H7 cells. From 103 to 108 CFU of E. coli O157:H7 cells/ml was quantified in broth or skim milk, and cell densities predicted by QC-PCR were highly related to viable cell counts (r2 = 0.99 and 0.93, respectively). QC-PCR has potential for quantitative detection of pathogenic bacteria in foods.  相似文献   

11.
《Luminescence》2004,19(4):193-198
A chemiluminescence‐based assay is developed for the rapid detection of Escherichia coli in fresh produce. The assay was based on the reaction of β‐galactosidase enzyme from E. coli with a phenylgalactosidase‐substituted dioxetane substrate. Light emitted from the reaction was measured in a luminometer and data correlated with counts of E. coli enumerated on sorbitol–MacConkey agar plates. A strain of E. coli O157:H7 was used to inoculate samples of fresh produce to differentiate the inoculum from the natural E. coli potentially present on the produce. Fresh market samples were tested for generic E. coli and E. coli O157:H7. Signi?cant differences in light emission were found in samples with high initial E. coli counts when market samples were compared to respective heat‐treated samples. The assay was able to detect E. coli in all produce tested, particularly at higher contamination or inoculation levels. The sensitivity of the assay ranged between 102–105 CFU within 30 min. The chemiluminescence assay provides a simple and rapid method for detection of viable E. coli, an important step towards enhancing food safety. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

12.
Previously, we produced two groups of gnotobiotic mice, GB-3 and GB-4, which showed different responses to Escherichia coli O157:H7 challenge. E. coli O157:H7 was eliminated from GB-3, whereas GB-4 became carriers. In this study, we analysed the mechanisms of E. coli O157:H7 elimination using GB-3 and GB-4. When GB-3 and GB-4 mice were challenged with E. coli O157:H7, the E. coli O157:H7 population was reduced in the caecum of GB-3 when compared to that in the GB-4 caecum, although the numbers of E. coli O157:H7 in the small intestine were not significantly different between these two groups of gnotobiotic mice. The lag time of E. coli O157:H7 growth in a 50% GB-3 caecal suspension increased when compared to that in a GB-4 caecal suspension. Acetate and lactate were detected in the GB-3 caecal contents, and acetate and propionate in those from GB-4. Although E. coli O157:H7 growth was not suppressed when it was cultured in anaerobic broth supplemented with these organic acids, the motility of E. coli O157:H7 was suppressed when it was cultured on semi-solid agar supplemented with the combination of acetate and lactate. These results indicate that the organic acid profile in the caecum is an important factor related to the elimination of E. coli O157:H7 from the intestine.  相似文献   

13.
Enterohemorrhagic E. coli O157: H7 (EHEC) is a major foodborne pathogen capable of causing diarrhea and vomiting, with further complications such as hemolytic‐uremic syndrome (HUS). The aim of this study was to use the real‐time PCR method to quantify the survival of Escherichia coli O157:H7/pGFP in phyllosphere (leaf surface), rhizosphere (volume of soil tightly held by plant roots), and non‐rhizosphere soils (sand and clay) irrigated with contaminated water and compare the results obtained between real‐time PCR method and conventional plate counts. The real‐time PCR probe was designed to hybridize with the (eae) gene of E. coli O157:H7. The probe was incorporated into real‐time PCR containing DNA extracted from the phyllosphere, rhizosphere, and non‐rhizosphere soils irrigated with water artificially contaminated with E. coli O157:H7. The detection limit for E. coli O157:H7 quantification by real‐time PCR was 2.3 × 103 in the rhizosphere and phyllosphere samples. E. coli O157:H7 survived longer in rhizosphere soil than the non‐rhizosphere soil. The concentration of E. coli O157:H7/pGFP in rhizosphere soils was ≥ 104 CFU/g in both soils at day 12 based on both plate count and real time PCR, with the clay soil significantly (P = 0.05) higher than the sandy soil. This data showed that E. coli O157H:7 can persist in the environment for more than 50 d, and this may pose some risk for both animal and human infection and provides a very significant pathway for pathogen recontamination in the environment.  相似文献   

14.
In this paper we describe evaluation and characterization of a novel assay that combines immunomagnetic separation and a fluorescently stained bacteriophage for detection of Escherichia coli O157:H7 in broth. When it was combined with flow cytometry, the fluorescent-bacteriophage assay (FBA) was capable of detecting 104 cells/ml. A modified direct epifluorescent-filter technique (DEFT) was employed in an attempt to estimate bacterial concentrations. Using regression analysis, we calculated that the lower detection limit was between 102 and 103 cells/ml; however, the modified DEFT was found to be an unreliable method for determining bacterial concentrations. The results of this study show that the FBA, when combined with flow cytometry, is a sensitive technique for presumptive detection of E. coli O157:H7 in broth cultures.  相似文献   

15.
Escherichia coli O157:H7 is an important food-borne pathogen. Often E. coli O157:H7 is difficult to detect, because it is present sporadically at very low levels together with very high levels of competitor organisms which can be difficult to distinguish phenotypically. Cultural methods are time-consuming and give variable results in the detection of E. coli O157:H7. This study examined the performance of BAX for Screening/E. coli O157:H7, a new rapid method for the detection of E. coli O157:H7, against traditional and improved cultural methods and an immunodiffusion assay. All cultural methods demonstrated inadequacy in detecting the presence of E. coli O157:H7 in inoculated samples. The limitations of these cultural methods further complicate evaluation of screening methodologies. The BAX for Screening/E. coli O157:H7 assay outperformed the other methods, with a detection rate of 96.5%, compared to 39% for the best cultural method and 71.5% for the immunodiffusion method. The BAX for Screening/E. coli O157:H7 assay proved to be a rapid, highly sensitive test for the detection of low levels of E. coli O157:H7 in ground beef.  相似文献   

16.
Thirty-two steers orally inoculated with a four-strain mixture (1010 CFU) of nalidixic acid-resistant Escherichia coli O157:H7 had sun-dried Ascophyllum nodosum seaweed (Tasco-14™) added to their barley-based diet (860 g/kg barley grain and 90 g/kg whole crop barley silage, dry matter basis) to assess its effectiveness in reducing fecal shedding of the pathogen. Steers were housed in four groups of eight and received Tasco-14™ in the diet, in place of barley, at levels (as fed) of 10 g/kg for 14 days (T1-14), 20 g/kg for 7 days (T2-7), 20 g/kg for 14 days (T2-14), or not at all (i.e., control, CON). The dietary treatments commenced 7 days after E. coli O157:H7 inoculation and fecal shedding patterns were examined over 14 weeks. Water, water–trough interface, feed and fecal pat samples were also collected weekly and cultured for E. coli O157:H7. Detection of the pathogen in fecal samples was less frequent (P<0.05) in T1-14 (99/168) and T2-7 (84/168) versus CON (135/168) and T2-14 (115/168), and the concentrations of E. coli O157:H7 recovered in feces from T1-14 and T2-7 steers were lower (P<0.005) than from CON or T2-14 steers. Rates of decline in shedding of E. coli O157:H7 were similar among treatments, but final numbers of E. coli O157:H7 were lower (P<0.05) in T1-14 and T2-7 as compared to T2-14 and CON. Fecal volatile fatty acid concentrations and pH were similar among treatments, suggesting no fecal alterations that were antagonistic to survival. E. coli O157:H7 was present in 1 (from T2-7) of 56 cattle drinking water samples, 2 of 56 (T1-14, CON) feed samples and 32 of 56 fecal pats. A second experiment investigated effects of the dietary treatment on growth performance of non-inoculated sheep. Tasco-14™ was administered to 40 individually fed Canadian Arcott lambs beginning at day 56 of a 105-day finishing period. The lambs received Tasco-14™ at 0 g/kg (control, CON), at 10 g/kg for 14 days (T1-14), 20 g/kg for 14 days (T2-14), 10 g/kg for 28 days (T1-28) or at 20 g/kg for 7 days (T2-7) as a top-dress on their pelleted, barley grain-based diet (n = 8). E. coli O157:H7 was not isolated from fecal samples collected at 4-week intervals, but generic E. coli populations were lower (P<0.05) in T1-28 lambs than in other treatments. Average daily gain, feed intake, feed efficiency and carcass traits did not differ among treatments. Our challenge study supports past studies showing that Tasco-14™ decreases shedding of E. coli O157:H7 by cattle. The lamb study shows that this additive did not directly affect feed intake or animal growth.  相似文献   

17.
A protocol for the quantitative detection of Escherichia coli O157 in raw and concentrated surface waters using immunomagnetic electrochemiluminescence (IM-ECL) was developed and optimized. Three antibody sandwich formats were tested: commercial anti-O157:H7 IM beads, IM beads made in-house with a polyclonal anti-O157:H7 immunoglobulin G (IgG), or IM beads made in-house with a monoclonal anti-O157:H7 IgG coupled with a polyclonal anti-O157:H7 IgG to which an electrochemiluminescent label (TAG) was attached. The monoclonal IM bead-polyclonal TAG format was chosen for optimization because it gave lower background levels and linear regression slopes of ca. 1.0, indicative of a constant ECL signal per cell. The dynamic range was ca. 101 to 105 cells ml−1 in phosphate-buffered saline and in raw water samples. The monoclonal IM beads selectively captured E. coli O157 cells in the presence of ca. 108 cells of a non-O157 strain of E. coli ml−1. Background ECL signals from concentrated (100-fold) water samples were substantially higher and more variable than raw water samples. The background signal was partially eliminated by the addition of polyvinylpolypyrrolidone. Successive cell capture incubations, termed sequential bead capture (SBC), were optimized for establishing baseline ECL values for individual water samples. The linear dynamic range with SBC was ca. 102 to 105 E. coli O157 cells ml of concentrated water−1. To validate the protocol, 10-liter surface water samples were spiked with ca. 5,000 E. coli O157 (Odwalla) cells and concentrated by vortex filtration, and 1- or 3-ml aliquots were analyzed by IM-ECL. Differential ECL signals (SBC) from 1- and 3-ml samples were statistically significant and were generally consistent with standard curves for these cell concentrations. Enrichments were conducted with aliquots of spiked raw water and concentrated water using EC broth and minimal lactose broth (MLB). All tubes with concentrated water became turbid and gave a positive ECL response for E. coli O157 (>10,000 ECL units); MLB gave a somewhat higher detection rate with spiked raw water. The potential sensitivity of the IM-ECL assay is ca. 25 E. coli O157 cells ml of raw water−1, 25 cells 100 ml of 100-fold concentrated water−1, or 1 to 2 viable cells liter−1 with concentration and enrichment. The IM-ECL assay appears suitable for routine analysis and screening of water samples.  相似文献   

18.
Two pathogenic microorganisms Escherichia coli O157:H7 and Staphylococcus aureus, suspended in peptone solution (0.1% w/v) were treated with 12, 14, 16 and 20 kV/cm electric field strengths with different pulse numbers up to 60 pulses. Pulsed electric field (PEF) treatment at 20 kV/cm with 60 pulses provided nearly 2 log reduction in viable cell counts of E. coli O157:H7 and S. aureus. S. aureus cells were slightly more resistant than E.coli O157:H7 cells. The results related to the effect of initial cell concentration of E. coli O157:H7 on the PEF inactivation showed that more inactivation was obtained by decreasing initial cell concentration. Any possible injury by PEF was also investigated after applying 20 kV/cm electric field to the microorganisms. As a result, it was determined that there was 35.92 to 43.36% injury in E. coli O157:H7 cells, and 17.26 to 30.86% injury in S. aureus cells depending on pulse number. The inactivation results were also described by a kinetic model.  相似文献   

19.
Summary Escherichia coli, including Shiga-like toxin producing E. coli (STEC), serogroup O157:H7 and E. coli O157, were isolated from raw beef marketed in Sarawak and Sabah, East Malaysia. Molecular subtyping by pulsed-field gel electrophoresis (PFGE) was performed on 51 confirmed E. coli isolates. Of the 51 isolates, five were E. coli O157:H7, four E. coli O157, two non-O157 STEC and 40 other E. coli isolates (non-STEC). Digestion of chromosomal DNA from these E. coli isolates with restriction endonuclease XbaI (5′-TCTAGA-3′), followed by PFGE, produced 45 restriction endonuclease digestion profiles (REDPs) of 10–18 bands. E. coli O157:H7 isolates from one beef sample were found to have identical PFGE profiles. In contrast, E. coli serogroup O157 from different beef samples displayed considerable differences in their PFGE profiles. These suggested that E. coli isolates of both serogroups were not closely related. A large variety of PFGE patterns among non-STEC isolates were observed, demonstrating a high clonal diversity of E. coli in the beef marketed in East Malaysia. The distance matrix values (D), calculated showed that none of the pathogenic E. coli strains displayed close genetic relationship with the non-STEC strains. Based on the PFGE profiles, a dendrogram was generated and the isolates were grouped into five PFGE clusters (A–E). From the dendrogram, the most related isolates were E. coli O157:H7, grouped within cluster B. The STEC O157:H7 beef isolates were more closely related to the clinical E. coli O157:H7 isolate than the E. coli O157:H7 reference culture, EDL933. Cluster A, comprising many of other E. coli isolates was shown to be the most heterogeneous. PFGE was shown to possess high discriminatory power in typing pathogenic and non-pathogenic E. coli strains, and useful in studying possible clonal relationship among strains.  相似文献   

20.
Aims: The aim of this study was to develop and optimize a novel method that combines ethidium bromide monoazide (EMA) staining with real‐time PCR for the detection of viable Escherichia  coli O157:H7 in ground beef. EMA can penetrate dead cells and bind to intracellular DNA, preventing its amplification via PCR. Methods and Results: Samples were stained with EMA for 5 min, iced for 1 min and exposed to bright visible light for 10 min prior to DNA extraction, to allow EMA binding of the DNA from dead cells. DNA was then extracted and amplified by TaqMan® real‐time PCR to detect only viable E. coli O157:H7 cells. The primers and TaqMan® probe used in this study target the uidA gene in E. coli O157:H7. An internal amplification control (IAC), consisting of 0·25 pg of plasmid pUC19, was added in each reaction to prevent the occurrence of false‐negative results. Results showed a reproducible application of this technique to detect viable cells in both broth culture and ground beef. EMA, at a final concentration of 10 μg ml?1, was demonstrated to effectively bind DNA from 108 CFU ml?1 dead cells, and the optimized method could detect as low as 104 CFU g?1 of viable E. coli O157:H7 cells in ground beef without interference from 108 CFU g?1 of dead cells. Conclusions: EMA real‐time PCR with IAC can effectively separate dead cells from viable E. coli O157:H7 and prevent amplification of DNA in the dead cells. Significance and Impact of the Study: The EMA real‐time PCR has the potential to be a highly sensitive quantitative detection technique to assess the contamination of viable E. coli O157:H7 in ground beef and other meat or food products.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号