首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 546 毫秒
1.
The refractive index resolution of a surface plasmon resonance (SPR) sensor has been significantly improved these years; however, higher sensing performance is always desired. In this work, we propose a line-monitoring, long-range SPR sensor whose resolution is much better than conventional SPR sensors. Also, in contrast to mono-channel detection, multichannel detection, using line-monitoring technique, can detect multiple channels concurrently. In this way, this system achieves a refractive index resolution of 4.0?×?10??7 refractive index units and can monitor multiple molecular interactions simultaneously. Finally, a model experiment detecting the Escherichia coli bacteria has demonstrated the potential for biomedical applications of this system.  相似文献   

2.
Zeng  Youjun  Zhou  Jie  Xiao  Xiaoping  Wang  Lei  Qu  Junle  Li  Xuejin  Gao  Bruce Zhi  Shao  Yonghong 《Plasmonics (Norwell, Mass.)》2019,14(6):1497-1504

A speckle-free fast angular interrogation surface plasmon resonance imaging (SPRi) sensor based on a diode-pumped all-solid-state laser and galvanometer is reported in this work. A bidirectional scan using a galvanometer realizes the fast scanning of the incidence angle. The experimental results showed that the time needed for completing an SPR dip measurement was decreased to 0.5 s. And through cascading an immovable diffuser and two diffusers rotating in opposite directions, laser speckle was eliminated. The dynamic detection range and the sensitivity reached 4.6 × 10−2 and 1.52 × 10−6 refractive index unit (RIU), respectively, in a 2D array sensor when the angle scanning range was set as 7.5°. More importantly, the results demonstrated that the angular interrogation SPR imaging sensor scheme had the capability to perform fast and high-throughput detection of biomolecular interactions at 2D sensor arrays.

  相似文献   

3.
This paper reports the application of differential phase surface plasmon resonance (SPR) imaging in two-dimensional (2D) protein biosensor arrays. Our phase imaging approach offers a distinct advantage over the conventional angular SPR technique in terms of utilization efficiency of optical sensor elements in the imaging device. In the angular approach, each biosensor site in the biosensor array requires a linear array of optical detector elements to locate the SPR angular dip. The maximum biosensor density that a two-dimensional imaging device can offer is a one-dimensional SPR biosensor array. On the other hand, the phase-sensitive SPR approach captures data in the time domain instead of the spatial domain. It is possible that each pixel in the captured interferogram represents one sensor site, thus offering high-density two-dimensional biosensor arrays. In addition, our differential phase approach improves detection resolution through removing common-mode disturbances. Experimental results demonstrate a system resolution of 8.8 x 10(-7)RIU (refractive index unit). Real-time monitoring of bovine serum albumin (BSA)/anti-BSA binding interactions at various concentration levels was achieved using a biosensor array. The detection limit was 0.77 microg/ml. The reported two-dimensional SPR biosensor array offers a real-time and non-labeling detection tool for high-throughput protein array analysis. It may find promising applications in protein therapeutics, drug screening and clinical diagnostics.  相似文献   

4.
Du  Bobo  Yang  Yuan  Zhang  Yang  Yang  Dexing 《Plasmonics (Norwell, Mass.)》2019,14(2):457-463

In this article, a surface plasmon resonance (SPR) biosensor based on D-typed optical fiber coated by Al2O3/Ag/Al2O3 film is investigated numerically. Resonance in near infrared with an optimized architecture is achieved. Refractive index sensitivity of 6558 nm/RIU (refractive index unit) and detection limit of 1.5 × 10−6 RIU, corresponding to 0.4357 nm/μM and detection limit of 23 nM in BSA (bovine serum albumin) concentration sensing, are obtained. The analysis of the performance of the sensor in gaseous sensing indicates that this proposed SPR sensor is much suitable for label-free biosensing in aqueous media.

  相似文献   

5.
A photonic crystal fiber (PCF)-based surface plasmon resonance (SPR) probe with gold nanowires as the plasmonic material is proposed in this work. The coupling characteristics and sensing properties of the probe are numerically investigated by the finite element method. The probe is designed to detect low refractive indices between 1.27 and 1.36. The maximum spectral sensitivity and amplitude sensitivity are 6 × 103 nm/RIU and 600 RIU?1, respectively, corresponding to a resolution of 2.8 × 10?5 RIU for the overall refractive index range. Our analysis shows that the PCF-SPR probe can be used for lower refractive index detection.  相似文献   

6.
We propose a highly sensitive novel diamond ring fiber (DRF)-based surface plasmon resonance (SPR) sensor for refractive index sensing. Chemically active plasmonic material (gold) layer is coated inside the large cavity of DRF, and the analyte is infiltrated directly through the fiber instead of selective infiltration. The light guiding properties and sensing performances are numerically investigated using the finite element method (FEM). The proposed sensor shows a maximum wavelength and amplitude interrogation sensitivity of 6000 nm/RIU and 508 RIU?1, respectively, over the refractive index range of 1.33–1.39. Additionally, it also shows a sensor resolution of 1.67 × 10?5 and 1.97 × 10?5 RIU by following the wavelength and amplitude interrogation methods, respectively. The proposed diamond ring fiber has been fabricated following the standard stack-and-draw method to show the feasibility of the proposed sensor. Due to fabrication feasibility and promising results, the proposed DRF SPR sensor can be an effective tool in biochemical and biological analyte detection.  相似文献   

7.

Surface plasmon resonance (SPR)–based structures are finding important applications in sensing biological as well as inorganic samples. In SPR techniques, an angle-resolved reflection (R) profile of the incident light from a metal-dielectric interface is measured and the resonance characteristics are extracted for the identification of the target sample. However, the performance, and hence the applicability of these structures, suffers when the weight and concentration of the target samples are small. Here, we show that SPR-based sensors can create strong magnetism at optical frequency, which can be used for the detection of target samples instead of using the conventional R profiles, as the magnetic resonance varies depending on the refractive index of the target sample. Using scattering parameters retrieval method, we computationally find out the effective permeability (μeff) of a SPR sensor with a structure based on Kretschmann configuration, and use it to calculate the performance of the sensor. A comparison with the conventional technique that uses R profile to detect a target sample shows a significant increase in the sensor performance when μeff is used instead.

  相似文献   

8.
We report a new high-throughput surface plasmon resonance (SPR) sensor based on combination of SPR imaging with polarization contrast and a spatially patterned multilayer SPR structure. We demonstrate that this approach offers numerous advantageous features including high-contrast SPR images suitable for automated computer analysis, minimum crosstalk between neighboring sensing channels and inherent compensation for light level fluctuations. Applications of a laboratory prototype of the high-throughput SPR sensor with 108 sensing channels for refractometry and biosensing are described. In refractometric experiments, the noise-limited refractive index resolution of the system has been established to be 3 x 10(-6) refractive index unit (RIU). Experimental data on detection of human choriogonadotropin (hCG) suggest that in conjunction with monoclonal antibodies against hCG, the reported SPR imaging sensor is capable of detecting hCG at concentrations lower than 500 ng/ml.  相似文献   

9.
A large majority of surface plasmon resonance (SPR) sensors reported in the literature are designed to operate in the visible electromagnetic spectrum. However, the near-infrared, particularly at the telecommunications wavelength of 1550 nm, is also especially attractive for SPR sensing applications. In fact, SPR sensors operating in this region benefit from narrower resonance and deeper field penetration. In this paper, we report a theoretical and experimental study of an SPR sensor operating at a fixed wavelength of 1550 nm. The influence of the choice of metals and the interrogation methods on the sensitivity of the resulting SPR sensor is investigated. Two types of sensor chips (simple gold (Au) and bimetallic silver/Au structure) and three interrogation methods (monitoring of the position of the reflectivity minimum, the position of the centroid, and the intensity evolution of the reflectivity) are examined. We show that a refractive index resolution of 2.7?×?10?6 refractive index unit can be easily obtained, and with further optimization of the measurement system, the ultimate limit of detection is expected to be even lowered. Therefore, the approach discussed here already shows a promising potential for highly sensitive SPR sensors.  相似文献   

10.
Refractive index (RI) sensing is a powerful noninvasive and label-free sensing technique for the identification, detection and monitoring of microfluidic samples with a wide range of possible sensor designs such as interferometers and resonators 1,2. Most of the existing RI sensing applications focus on biological materials in aqueous solutions in visible and IR frequencies, such as DNA hybridization and genome sequencing. At terahertz frequencies, applications include quality control, monitoring of industrial processes and sensing and detection applications involving nonpolar materials.Several potential designs for refractive index sensors in the terahertz regime exist, including photonic crystal waveguides 3, asymmetric split-ring resonators 4, and photonic band gap structures integrated into parallel-plate waveguides 5. Many of these designs are based on optical resonators such as rings or cavities. The resonant frequencies of these structures are dependent on the refractive index of the material in or around the resonator. By monitoring the shifts in resonant frequency the refractive index of a sample can be accurately measured and this in turn can be used to identify a material, monitor contamination or dilution, etc.The sensor design we use here is based on a simple parallel-plate waveguide 6,7. A rectangular groove machined into one face acts as a resonant cavity (Figures 1 and 2). When terahertz radiation is coupled into the waveguide and propagates in the lowest-order transverse-electric (TE1) mode, the result is a single strong resonant feature with a tunable resonant frequency that is dependent on the geometry of the groove 6,8. This groove can be filled with nonpolar liquid microfluidic samples which cause a shift in the observed resonant frequency that depends on the amount of liquid in the groove and its refractive index 9.Our technique has an advantage over other terahertz techniques in its simplicity, both in fabrication and implementation, since the procedure can be accomplished with standard laboratory equipment without the need for a clean room or any special fabrication or experimental techniques. It can also be easily expanded to multichannel operation by the incorporation of multiple grooves 10. In this video we will describe our complete experimental procedure, from the design of the sensor to the data analysis and determination of the sample refractive index.  相似文献   

11.
We show that fluorescence lifetime imaging microscopy (FLIM) of green fluorescent protein (GFP) molecules in cells can be used to report on the local refractive index of intracellular GFP. We expressed GFP fusion constructs of Rac2 and gp91phox, which are both subunits of the phagocyte NADPH oxidase enzyme, in human myeloid PLB-985 cells and showed by high-resolution confocal fluorescence microscopy that GFP-Rac2 and GFP-gp91phox are targeted to the cytosol and to membranes, respectively. Frequency-domain FLIM experiments on these PLB-985 cells resulted in average fluorescence lifetimes of 2.70 ns for cytosolic GFP-Rac2 and 2.31 ns for membrane-bound GFP-gp91phox. By comparing these lifetimes with a calibration curve obtained by measuring GFP lifetimes in PBS/glycerol mixtures of known refractive index, we found that the local refractive indices of cytosolic GFP-Rac2 and membrane-targeted GFP-gp91phox are ∼1.38 and ∼1.46, respectively, which is in good correspondence with reported values for the cytosol and plasma membrane measured by other techniques. The ability to measure the local refractive index of proteins in living cells by FLIM may be important in revealing intracellular spatial heterogeneities within organelles such as the plasma and phagosomal membrane.  相似文献   

12.
Plant lectin recognition of glycans was evaluated by SPR imaging using a model array of N-biotinylated aminoethyl glycosides of β-d-glucose (negative control), α-d-mannose (conA-responsive), β-d-galactose (RCA120-responsive) and N-acetyl-β-d-glucosamine (WGA-responsive) printed onto neutravidin-coated gold chips. Selective recognition of the cognate ligand was observed when RCA120 was passed over the array surface. Limited or no binding was observed for the non-cognate ligands. SPR imaging of an array of 40 sialylated and unsialylated glycans established the binding preference of hSiglec7 for α2-8-linked disialic acid structures over α2-6-sialyl-LacNAcs, which in turn were recognized and bound with greater affinity than α2-3-sialyl-LacNAcs. Affinity binding data could be obtained with as little as 10–20 μg of lectin per experiment. The SPR imaging technique was also able to establish selective binding to the preferred glycan ligand when analyzing crude culture supernatant containing 10–20 μg of recombinant hSiglec7-Fc. Our results show that SPR imaging provides results that are in agreement with those obtained from fluorescence based carbohydrate arrays but with the added advantage of label-free analysis.  相似文献   

13.
本文提出了复合表面等离子体(SPR)无标记检测及表面增强拉曼散射(SERS)的显微成像技术.证明了双模式SPR-SERS生物芯片的可实施性,即在同一芯片上实现了表面等离子共振和表面增强拉曼显微检测.鉴于双模芯片的高保真性,基于显微技术的高精准、多通道无标记检测技术有望在临床医学检测中得以广泛应用.  相似文献   

14.
A novel method for sensitivity enhancement of spectral surface plasmon resonance (SPR) biosensors was presented by reducing the refractive index of the sensing prism in the analysis of protein arrays. Sensitivity of spectral SPR biosensors with two different prisms (BK-7, fused silica) was analyzed by net shifts of resonance wavelength for specific interactions of GST–GTPase binding domain of p21-activated kinase-1 and anti-GST on a mixed thiol surface. Sensitivity was modulated by the refractive index of the sensing prism of the spectral SPR biosensors with the same incidence angle. The sensitivity of a spectral SPR biosensor with a fused silica prism was 1.6 times higher than that with a BK-7 prism at the same incidence angle of 46.2°. This result was interpreted by increment of the penetration depth correlated with evanescent field intensity at the metal/dielectric interface. Therefore, it is suggested that sensitivity enhancement is readily achieved by reducing the refractive index of the sensing prism of spectral SPR biosensors to be operated at long wavelength ranges for the analysis of protein arrays.  相似文献   

15.
A surface plasmon resonance (SPR) sensor based on D-shaped photonic crystal fiber (PCF) coated with indium tin oxide (ITO) film is proposed and numerically investigated. Thanks to the adjustable complex refractive index of ITO, the sensor can be operated in the near-infrared (NIR) region. The wavelength sensitivity, amplitude sensitivity, and phase sensitivity are investigated with different fiber structure parameters. Simulation results show that ~6000 nm/refractive index unit (RIU), ~148/RIU, and ~1.2?×?106 deg/RIU/cm sensitivity can be achieved for wavelength interrogation, amplitude interrogation, and phase interrogation, respectively, when the environment refractive index varies between 1.30 and 1.31. It is noted that the wavelength sensitivity and phase sensitivity are more pronounced with larger refractive index. The proposed SPR sensor can be used in various applications, including medicine, environment, and large-scale targets detection.  相似文献   

16.
We design terahertz (THz) surface-plasmon-resonance (SPR) sensors using a ferroelectric polyvinylidene fluoride (PVDF) thin layer for biological sensing. The reflectivity properties based on SPR are described using transfer matrix method (TMM) and numerically simulated using finite-difference time domain (FDTD) method. The sensing characteristics of the structure are systematically analyzed through the examination of the reflectivity spectrum. The results reveal that the pronounced SPR resonance peak has quasi-linear relationship with the refractive index variation of the material under investigation. Through analyzing and optimizing the structural parameters of the THz SPR sensor, we achieved the theoretical value of the refractive index detection sensitivity as high as 0.393 THz/unit change of refractive index (RIU) for a 20-μm-thick liquid sample with a 10-μm PVDF layer. This work shows great promise toward realizing a THz SPR sensor with high sensitivity for identifying the signatures of biological fluid sample.  相似文献   

17.
A small array of subwavelength apertures patterned in a gold film on glass was characterized for use as a biosensor. It is widely believed that such arrays allow the resonance of photons with surface plasmons in the metallic film. Surface plasmon methods (and other evanescent wave methods) are extremely well suited for the measure of real time biospecific interactions. An extremely high sensitivity of 88,000%/refractive index unit was measured on an array with theoretical active area of .09 microm2. The formation of a biological monolayer was monitored. Both sensitivity and resolution were determined through measurement. The measured resolution, for a sensor with an active area of less than 1.5 microm2, is 9.4 x 10(-8) refractive index units which leads to a calculated sensitivity of 3.45E6%/refractive index unit. These values far exceed theoretical and calculated values of other grating coupled surface plasmon resonance (SPR) detectors and prism based SPR detectors. Because the active sensing area can be quite small (.025 microm2) single molecule studies are possible as well as massive multiplexing on a single chip format.  相似文献   

18.
Gu  Sanfeng  Sun  Wei  Li  Meng  Zhang  Tianheng  Deng  Ming 《Plasmonics (Norwell, Mass.)》2022,17(3):1129-1137

A dual-core and dual D-shaped photonic crystal fiber (PCF)-based surface plasmon resonance (SPR) sensor with silver and aluminum nitride (AlN) films is designed. The distribution characteristics of the electromagnetic fields of core and plasmon modes, as well as the sensing properties, are numerically studied by finite element method (FEM). The structure parameters of the designed sensor are optimized by the optical loss spectrum. The results show the resonance wavelength variation of 489 nm for the refractive index (RI) range of 1.36?~?1.42. In addition, a maximum wavelength sensitivity of 13,400 nm/RIU with the corresponding RI resolution of 7.46?×?10?6 RIU is obtained in the RI range of 1.41?~?1.42. The proposed sensor with the merits of high sensitivity, low cost, and simple structure has a wide application in the fields of RI sensing, such as hazardous gas detection, environmental monitoring, and biochemical analysis.

  相似文献   

19.
Pang  Kai  Dong  Wei  Zhang  Bing  Zhan  Shuyue  Wang  Xiaoping 《Plasmonics (Norwell, Mass.)》2016,11(4):1119-1128

We demonstrate that a designed bimetallic chip is capable of improving the performance of a surface plasmon resonance (SPR) sensor based on angular interrogation. Through a numerical simulation and a refractometry experiment, we prove that this bimetallic chip can effectively reduce the noise level by about a factor of 2 compared to the traditional SPR sensors that only use a single gold film. The bimetallic chip presents a lower refractive index resolution of 5.3 × 10−7 refractive index units. In addition, the enhancement of the electric field intensity at the surface of the configuration by a factor of 2 makes it possible to have a high sensitivity in a larger region, which promotes the biosensing applications of the chip. Through a simple and novel method for the detection of cadmium ions (Cd2+) based on the bimetallic configuration, a detection level for Cd2+ (0.01 μM or 1.12 ppb) can be realized, which compares favorably with similar studies.

  相似文献   

20.
The spectral phase shift of surface plasmon resonance (SPR) in the Kretschmann configuration is modeled for aqueous solutions of NaCl (analytes) and an SPR structure consisting of gold and chromium layers deposited on an SF10 glass slide. Using the material dispersion of the SPR structure and the analyte, the SPR phase shift, its spectral derivative, and the spectral dependence of the ratio of the reflectances of p- and s-polarized waves are determined for aqueous solutions of NaCl when the concentration of NaCl in water and the refractive index range from 0 to 10 weight percent (wt%) and from 1.3334 to 1.3515 RIU, respectively. In addition, theoretical modeling is accompanied by experiment and the position of a sharp maximum in the measured spectral derivative of the SPR phase shift changes in a range from 596 to 626 nm. From the measurements, a sensitivity to concentration of 3.83 nm/wt% and a detection limit of 7.3 × 10?7 RIU at a wavelength of 612.36 nm are obtained, and very good agreement between theory and experiment is confirmed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号