首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Background

In our institution, the fixation technique in treating idiopathic scoliosis was shifted from hybrid fixation to the all-screw method beginning in 2000. We conducted this study to assess the intermediate -term outcome of all-screw method in treating adolescent idiopathic scoliosis (AIS).

Methods

Forty-nine consecutive patients were retrospectively included with minimum of 5-year follow-up (mean, 6.1; range, 5.1-7.3 years). The average age of surgery was 18.5 ± 5.0 years. We assessed radiographic measurements at preoperative (Preop), postoperative (PO) and final follow-up (FFU) period. Curve correction rate, correction loss rate, complications, accuracy of pedicle screws and SF-36 scores were analyzed.

Results

The average major curve was corrected from 58.0 ± 13.0° Preop to 16.0 ± 9.0° PO(p < 0.0001), and increased to 18.4 ± 8.6°(p = 0.12) FFU. This revealed a 72.7% correction rate and a correction loss of 2.4° (3.92%). The thoracic kyphosis decreased little at FFU (22 ± 12° to 20 ± 6°, (p = 0.25)). Apical vertebral rotation decreased from 2.1 ± 0.8 PreOP to 0.8 ± 0.8 at FFU (Nash-Moe grading, p < 0.01). Among total 831 pedicle screws, 56 (6.7%) were found to be malpositioned. Compared with 2069 age-matched Taiwanese, SF-36 scores showed inferior result in 2 variables: physical function and role physical.

Conclusion

Follow-up more than 5 years, the authors suggest that all-screw method is an efficient and safe method.  相似文献   

2.
In radiological assessment of scoliosis, some prognostic value is given to vertebral rotation. An improved method for measuring vertebral rotation is introduced. It differs from the known methods by a specific selection of vertebral model parameters describing location of pedicles relative to the vertebral body. Vertebral model parameters have been determined from 150 axial X-rays of vertebral specimens. Application of measured parameters yields accuracy of about +/- 5 degrees in assessing vertebral rotation. Good agreement is found with parameters of six scoliotic vertebrae, investigated by CT-scans. A method for clinical presentation of measurement results is proposed.  相似文献   

3.

Purpose

This study aims to compare the biomechanical properties of the novel pedicle screw and plate system with the traditional rod system in asymmetrical posterior stabilization for minimally invasive transforaminal lumbar interbody fusion (MI-TLIF). We compared the immediate stabilizing effects of fusion segment and the strain distribution on the vertebral body.

Methods

Seven fresh calf lumbar spines (L3-L6) were tested. Flexion/extension, lateral bending, and axial rotation were induced by pure moments of ± 5.0 Nm and the range of motion (ROM) was recorded. Strain gauges were instrumented at L4 and L5 vertebral body to record the strain distribution under flexion and lateral bending (LB). After intact kinematic analysis, a right sided TLIF was performed at L4-L5. Then each specimen was tested for the following constructs: unilateral pedicle screw and rod (UR); unilateral pedicle screw and plate (UP); UR and transfacet pedicle screw (TFS); UP and TFS; UP and UR.

Results

All instrumented constructs significantly reduced ROM in all motion compared with the intact specimen, except the UR construct in axial rotation. Unilateral fixation (UR or UP) reduced ROM less compared with the bilateral fixation (UP/UR+TFS, UP+UR). The plate system resulted in more reduction in ROM compared with the rod system, especially in axial rotation. UP construct provided more stability in axial rotation compared with UR construct. The strain distribution on the left and right side of L4 vertebral body was significantly different from UR and UR+TFS construct under flexion motion. The strain distribution on L4 vertebral body was significantly influenced by different fixation constructs.

Conclusions

The novel plate could provide sufficient segmental stability in axial rotation. The UR construct exhibits weak stability and asymmetrical strain distribution in fusion segment, while the UP construct is a good alternative choice for unilateral posterior fixation of MI-TLIF.  相似文献   

4.
Clinical attempts are made to avoid rotating a flap and twisting the pedicle for fear of perfusion compromise. Torsion of an island rat groin flap pedicle is not a well-recognized experimental entity. The authors describe the results of island flap rotation with pedicle twisting in the rat groin flap model. Forty male Wistar rats were randomly divided into four groups of 10 animals each. In each group, bilateral groin flaps were elevated; one flap was sutured in place without rotation and the contralateral flap was subjected to 180, 270, 360, or 720 degrees of rotation. Blood flow within the flaps was assessed by laser Doppler flowmetry, and flap edema and necrosis were determined 10 days postoperatively. No differences were noted between control flaps and those subjected to 180 and 270 degrees of rotation. Although flaps subjected to 360 degrees of rotation demonstrated a large amount of postoperative edema and congestion of the subcutaneous tissue with some histologic changes, all flaps in this group survived. Measured flap weights at death were different from those of controls. All flaps subjected to 720 degrees of rotation underwent ischemic necrosis. Because of the differences between human skin architecture and rat skin architecture it cannot be concluded that similar results would be observed in any human skin flap. There might be three important points arising from this study of unknowingly twisted island groin flap pedicles in the rat model: (1) twisting of less than 360 degrees has no effect on flap survival; (2) twisting of 720 degrees is always associated with skin flap necrosis; (3) twisting of 360 degrees, although associated with some changes, does not cause skin flap necrosis.  相似文献   

5.
目的:进一步探讨经皮穿刺椎弓根途径椎体成形术与传统保守治疗方法的临床比较差异,从而为临床相关实践提供借鉴和参考依据。方法:2014年12月至2015年5月医院临床收治的胸腰椎椎体转移肿瘤患者共计88例,根据治疗方法分成研究组(经皮穿刺椎弓根途径椎体成形术组)和对照组(传统保守治疗方法组),每组患者44例。观察和比较两组患者实施不同治疗后的临床满意度。结果:研究组患者手术1d、1个月、3个月、6个月和1年后的临床满意度均显著的高于对照组,且组间比较差异均有统计学意义(P0.05)。结论:经皮穿刺椎弓根途径椎体成形术治疗胸腰椎椎体转移肿瘤的临床综合效果显著,与传统保守治疗方法相比较可有效改善和提高患者的生活质量。  相似文献   

6.
The purpose of this study was to understand the acoustic properties of human vertebral cancellous bone and to study the feasibility of ultrasound-based navigation for posterior pedicle screw fixation in spinal fusion surgery. Fourteen human vertebral specimens were disarticulated from seven un-embalmed cadavers (four males, three females, 73.14 ± 9.87 years, two specimens from each cadaver). Seven specimens were used to measure the transmission, including tests of attenuation and phase velocity, while the other seven specimens were used for backscattered measurements to inspect the depth of penetration and A-Mode signals. Five pairs of unfocused broadband ultrasonic transducers were used for the detection, with center frequencies of 0.5 MHz, 1 MHz, 1.5 MHz, 2.25 MHz, and 3.5 MHz. As a result, good and stable results were documented. With increased frequency, the attenuation increased (P<0.05), stability of the speed of sound improved (P<0.05), and penetration distance decreased (P>0.05). At about 0.6 cm away from the cortical bone, warning signals were easily observed from the backscattered measurements. In conclusion, the ultrasonic system proved to be an effective, moveable, and real-time imaging navigation system. However, how ultrasonic navigation will benefit pedicle screw insertion in spinal surgery needs to be determined. Therefore, ultrasound-guided pedicle screw implantation is theoretically effective and promising.  相似文献   

7.
Multi-scale finite element (FE) model is a cost-effective way to analyse stress response of micro-level structures to the changes in loading at macro-level. This study deals with the development of a multi-scale model of a human vertebra and stress changes in the pedicle at high resolution after a gross fracture at the posterior neural arch. Spondylolysis (pars fracture) is a painful condition occurring in the vertebral neural arch and common especially among the athletic young population. The fracture of the pars significantly alters load distribution and load transfer characteristics at the neural arch. Structural changes in the posterior vertebra due to the new loading patterns can trigger secondary complications. Clinical reports have shown the association of pedicle hypertrophy or pedicle fracture with unilateral pars fractures. However, the biomechanical consequences of pars fracture and its effect on the pedicle have never been studied in detail. Therefore, we prepared a multi-scale model of posterior vertebra with continuum laminar complex model combined with micro-FE model of a pedicle section. The results showed that stress at the contralateral pars and pedicle increased after unilateral pars fracture simulation. High-stress regions were found around the outer boundaries of the pedicle. This model and information are helpful in understanding the stress changes in the pedicle and can be used for adaptive remodelling studies.  相似文献   

8.
Moe1 is a conserved fission yeast protein that negatively affects microtubule stability/assembly. We conducted a two-hybrid screen to search for Moe1-binding proteins and isolated Mal3, a homologue of human EB1. We show that Moe1 and Mal3 expressed in bacteria form a complex and that Moe1 and Mal3 expressed in fission yeast cosediment with microtubules. Deletion of either moe1 or mal3 does not result in lethality; however, deletion of both moe1 and mal3 leads to cell death in the cold. The resulting cells appear to die of chromosome missegregation, which correlates with the presence of abnormal spindles. We investigated the cause for the formation of monopolar spindles and found that only one of the two spindle pole bodies (SPBs) contains gamma-tubulin, although both SPBs appear to be equal in size and properly inserted in the nuclear membrane. Moreover, the moe1 mal3 double null mutant in the cold contains abnormally short and abundant interphase microtubule bundles. These data suggest that Moe1 and Mal3 play a role in maintaining proper microtubule dynamics/integrity and distribution of gamma-tubulin to the SPBs during mitosis. Finally, we show that human Moe1 and EB1 can each rescue the phenotype of the moe1 mal3 double null mutant and form a complex, suggesting that these proteins are part of a well-conserved mechanism for regulating spindle functioning.  相似文献   

9.
The purpose of our study is to develop and validate three-dimensional finite element models of transforaminal lumbar interbody fusion, and explore the most appropriate method of fixation and fusion by comparing biomechanical characteristics of different fixation method. We developed four fusion models: bilateral pedicle screws fixation with a single cage insertion model (A), bilateral pedicle screws fixation with two cages insertion model (B), unilateral pedicle screws fixation with a single cage insertion model (C), and unilateral pedicle screws fixation with two cages insertion model (D); the models were subjected to different forces including anterior bending, posterior extension, left bending, right bending, rotation, and axial compressive. The von Mises stress of the fusion segments on the pedicle screw and cages was recorded. Angular variation and stress of pedicle screw and cage were compared. There were differences of Von Mises peak stress among four models, but were within the range of maximum force. The angular variation in A, B, C, and D decreased significantly compared with normal. There was no significant difference of angular variation between A and B, and C and D. Bilateral pedicle screws fixation had more superior biomechanics than unilateral pedicle screws fixation. In conclusion, the lumbar interbody fusion models were established using varying fixation methods, and the results verified that unilateral pedicle screws fixation with a single cage could meet the stability demand in minimal invasive transforaminal interbody fusion.  相似文献   

10.
The 2D shape of the lumbar spine in the sagittal plane can be determined from lordosis angles measured between the corresponding end-plates of the vertebral bodies or by using an active shape model (ASM) of the vertebral body outline. The ASM was previously shown to be a more efficient and reliable method, but its accuracy has not been assessed. The aim of this study was to determine the accuracy of an ASM for characterising lumbar spine shape and compare this to conventional measurements. Images of 25 different lumbar spine shapes were generated and measured, using both methods, by three independent observers. The accuracy of the ASM, determined from lordosis angles predicted by the model, was found to be better than conventional measurements.  相似文献   

11.
中国汉族男性腰椎的身高推断   总被引:5,自引:0,他引:5  
本文研究了中国汉族男性腰椎的测量及腰椎推断身高的方法。测量指标有 :椎体前高、椎体后高、椎体上矢径、椎体下矢径、椎体上横径、椎体下横径、椎体中部横径、椎孔矢状径、椎孔横径、左侧椎弓根厚度。将各腰椎的测量数据与身高进行了相关分析并建立了中国汉族男性腰椎推断身高的回归方程。本研究所建立的方程 ,可以用于中国汉族男性腰椎的身高推断。  相似文献   

12.
A comprehensive, geometrically accurate, nonlinear C0-C7 FE model of head and cervical spine based on the actual geometry of a human cadaver specimen was developed. The motions of each cervical vertebral level under pure moment loading of 1.0 Nm applied incrementally on the skull to simulate the movements of the head and cervical spine under flexion, tension, axial rotation and lateral bending with the inferior surface of the C7 vertebral body fully constrained were analysed. The predicted range of motion (ROM) for each motion segment were computed and compared with published experimental data. The model predicted the nonlinear moment-rotation relationship of human cervical spine. Under the same loading magnitude, the model predicted the largest rotation in extension, followed by flexion and axial rotation, and least ROM in lateral bending. The upper cervical spines are more flexible than the lower cervical levels. The motions of the two uppermost motion segments account for half (or even higher) of the whole cervical spine motion under rotational loadings. The differences in the ROMs among the lower cervical spines (C3-C7) were relatively small. The FE predicted segmental motions effectively reflect the behavior of human cervical spine and were in agreement with the experimental data. The C0-C7 FE model offers potentials for biomedical and injury studies.  相似文献   

13.
A new method is presented for estimating the parameters of two different models of a joint. The two models are: (1) A rotational joint with a fixed axis of rotation, also referred to as a hinge joint and (2) a ball and socket model, corresponding to a spherical joint. Given the motion of a set of markers, it is shown how the parameters can be estimated, utilizing the whole data set. The parameters are estimated from motion data by minimizing two objective functions. The method does not assume a rigid body motion, but only that each marker rotates around the same fixed axis of rotation or center of rotation. Simulation results indicate that in situations where the rigid body assumption is valid and when measurement noise is present, the proposed method is inferior to methods that utilize the rigid body assumption. However, when there are large skin movement artefacts, simulation results show the proposed method to be more robust.  相似文献   

14.
《Plains anthropologist》2013,58(96):125-135
Abstract

Analysis of artifacts recovered from the Moe site located in northwestern North Dakota reveals the presence of 15 blades and three blade-like flakes, the majority of which are made of Knife River Flint and have been modified by retouch flaking. A comparison of the Moe specimens to those from the Pelland site in northern Minnesota, the only other site from the study area which contains blades of Paleo-Indian age, indicates that the Moe specimens are smaller in all dimensions. The Pelland specimens are made of Knife River Flint and have been modified by retouch flaking. Examination of the literature on Paleo-Indian sites from the Plains region indicates that blade production is more common in Plano cultures particularly Agate Basin and Plainview-Goshen than in earlier Clovis or Folsom cultures or later Cody cultures. It is suggested that the Pelland and Moe site blades are Plano in age and most likely Agate Basin or Plainview-Goshen in cultural affiliation. A model provided by Leo Pettipas (1976) is used to suggest an eastward movement of Plains Plano cultures using Knife River Flint across southern Manitoba, eastern North Dakota, and into western and northern Minnesota following the recession of Glacial Lake Agassiz.  相似文献   

15.
Anchorage of pedicle screw instrumentation in the elderly spine with poor bone quality remains challenging. In this study, micro finite element (µFE) models were used to assess the specific influence of screw design and the relative contribution of local bone density to fixation mechanics. These were created from micro computer tomography (µCT) scans of vertebras implanted with two types of pedicle screws, including a full region-or-interest of 10 mm radius around each screw, as well as submodels for the pedicle and inner trabecular bone of the vertebral body. The local bone volume fraction (BV/TV) calculated from the µCT scans around different regions of the screw (pedicle, inner trabecular region of the vertebral body) were then related to the predicted stiffness in simulated pull-out tests as well as to the experimental pull-out and torsional fixation properties mechanically measured on the corresponding specimens. Results show that predicted stiffness correlated excellently with experimental pull-out strength (R2 > 0.92, p < .043), better than regional BV/TV alone (R2 = 0.79, p = .003). They also show that correlations between fixation properties and BV/TV were increased when accounting only for the pedicle zone (R2 = 0.66–0.94, p ≤ .032), but with weaker correlations for torsional loads (R2 < 0.10). Our analyses highlight the role of local density in the pedicle zone on the fixation stiffness and strength of pedicle screws when pull-out loads are involved, but that local apparent bone density alone may not be sufficient to explain resistance in torsion.  相似文献   

16.
This study investigated whether the external marker-defined spine inter-segmental rotation is different from the internal vertebral rotation, and explored how to estimate the latter from limited surface measurement. A kinematic model was first created to elucidate analytically the relation between the external and internal rotations. A novel approach guided by the model was proposed for deriving vertebral centers of rotation (CORs) from measured planar trajectories of skin-surface markers. The approach involved a recursive procedure for establishing local (anatomical) coordinate systems, and an optimization routine that identified the maximum-likelihood circles best fitting the marker trajectories in local coordinate systems. An experiment with 10 subjects (5 males and 5 females) was conducted to test the approach along with the model. Skin-surface markers were strategically placed over individual spinous processes and other body landmarks, and recorded by an opto-electronic system while sagittally symmetric load-lifting movements were being performed. For the majority (89%) of measured motions, the COR locations for lumbar vertebrae (L2-L5) were derived successfully: solutions resulting from the optimization routine met a convergence criterion governed by the model, and were in agreement with existing data from radiographic or cadaveric studies. Empirical results confirmed the differences between the external marker-defined inter-segmental motions and corresponding internal vertebral rotations (1.1-5.8 degrees on average, all statistically significant). The study demonstrated the necessity and viability of quantifying internal vertebral kinematics when utilizing non-invasive marker-based measurement for spine-related clinical diagnosis and biomechanical modeling.  相似文献   

17.
翁贞  张红庆  陈永杰  曾正义 《蛇志》2016,(3):286-287
目的分析老年骨质疏松脊柱压缩骨折行椎体后凸成形术的治疗方法及临床效果,为临床提供依据。方法回顾性分析我院2014年10月~2015年10月收治的老年骨质疏松脊柱压缩骨折患者40例的临床资料,全部患者均为椎体后壁完整疼痛性骨质疏松脊柱压缩骨折,均接受椎体后凸成形术治疗,经双侧椎弓根、椎弓根旁置入可扩张球囊,将骨折塌陷椎体进行复位,采取骨水泥填充球囊扩张产生的椎体内空腔,术后观察患者症状改善和骨折复位情况。结果 40例患者手术均顺利完成,术后48h内患者疼痛显著缓解,骨折椎体前缘以及中部高度丢失,从手术前的(12.5±2.2)mm、(9.1±1.3)mm减少到手术后的(4.6±1.4)mm、(3.3±1.0)mm;后凸畸形Cobb角从手术前的(22.2±5.1)°矫正到手术后的(9.1±4.6)°,其中1例患者术后出现少量骨水泥渗漏,1例患者手术过程中一侧穿刺管中出现脑脊液,即停止该侧手术。结论老年骨质疏松脊柱压缩骨折行椎体后凸成形术治疗效果显著,可以快速缓解患者的疼痛,使患者脊柱序列得到恢复,值得临床推广使用。  相似文献   

18.
A combined approach involving optimization and the finite element technique was used to predict biomechanical parameters in the lumbar spine during static lifting in the sagittal plane. Forces in muscle fascicles of the lumbar region were first predicted using an optimization-based force model including the entire lumbar spine. These muscle forces as well as the distributed upper body weight and the lifted load were then applied to a three-dimensional finite element model of the thoracolumbar spine and rib cage to predict deformation, the intradiskal pressure, strains, stresses, and load transfer paths in the spine. The predicted intradiskal pressures in the L3-4 disk at the most deviated from the in vivo measurements by 8.2 percent for the four lifting cases analyzed. The lumbosacral joint flexed, while the other lumbar joints extended for all of the four lifting cases studied (rotation of a joint is the relative rotation between its two vertebral bodies). High stresses were predicted in the posterolateral regions of the endplates and at the junctions of the pedicles and vertebral bodies. High interlaminar shear stresses were found in the posterolateral regions of the lumbar disks. While the facet joints of the upper two lumbar segments did not transmit any load, the facet joints of the lower two lumbar segments experienced significant loads. The ligaments of all lumbar motion segments except the lumbosacral junction provided only marginal moments. The limitations of the current model and possible improvements are discussed.  相似文献   

19.
Kim K  Kim YH  Lee S 《Journal of biomechanics》2011,44(8):1614-1617
It has been reported that the center of rotation of each vertebral body is located posterior to the vertebral body center. Moreover, it has been suggested that an optimized follower load (FL) acts posterior to the vertebral body center. However, the optimal position of the FL with respect to typical biomechanical characteristics regarding spinal stabilization, such as joint compressive force, shear force, joint moment, and muscle stress, has not been studied. A variation in the center of rotation of each vertebra was formulated in a three-dimensional finite element model of the lumbar spine with 117 pairs of trunk muscles. Then, the optimal translation of the FL path connecting the centers of rotations was estimated by solving the optimization problem that was to simultaneously minimize the compressive forces, the shear forces, and the joint moments or to minimize the cubic muscle stresses. An upright neutral standing position and a standing position with 200N in both hands were considered. The FL path moved posterior, regardless of the optimization criteria and loading conditions. The FL path moved 5.0 and 7.8mm posterior in upright standing and 4.1mm and 7.0mm posterior in standing with 200N in hands for each optimization scheme. In addition, it was presented that the optimal FL path may have advantages in comparison to the body center FL path. The present techniques may be important in understanding the spine stabilization function of the trunk muscles.  相似文献   

20.
For an ideal polysaccharide gel with a known total polymer chain contour length, crosslinks all of the same functionality and elastic chains all with the same contour length and stiffness, the gel crosslink density can readily be determined from measurements of the maximum volume of the swollen gel (Moe et al., (1991) Food Hydrocolloids, 5, (1/2), 119–123. In the case of randomly crosslinked polysaccharide gels, where the chain contour length between two adjacent crosslinks may vary greatly, it is often much more difficult to determine the crosslink density. This paper reports on an attempt to extend the use of maximum gel volume measurements to estimate crosslink density for the latter type of gel. This is done by calculating the maximum swelling volume for polymer networks with four-functional crosslinks, known elastic chain mean contour length and standard deviation. The numerical analysis involves the calculation of the equilibrium force at each crosslink as the network expands. This allows a detailed study of how the distribution of individual polymer chain contour lengths affects the maximum swelling volume. The computer simulation results are compared with the results from experimental measurements of the maximum volume of swollen covalently crosslinked sodium alginate gels.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏