首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A tidal flow constructed wetland system was investigated for the removal of organic matter and ammoniacal-nitrogen from diluted piggery wastewater. The results demonstrated that the operation of tidal flow enhanced the transfer of oxygen into wetland matrices. The supply of oxygen by the operation (473 gO2/m2d) matched the demand for wastewater treatment. The overall oxygen consumption rate in the system was considerably higher than the typical rate obtainable in conventional wetlands; most oxygen being used for the decomposition of organic matter. Compared with conventional systems, the tidal flow system demonstrated greater efficiency in the removal of organic matter. Significant nitrification did not take place, although 27-48% ammonia was removed from the wastewater. Immobilization by microbial cells and adsorption were the likely routes to remove ammonia under the specific experiment conditions. Percentage removals of BOD5, NH4-N and SS increased after effluent recirculation at a ratio of 1:1 was employed.  相似文献   

2.
The main objective of this study is to assess the achievability of stringent discharge criteria i.e. BOD(5)<15 mg/L, TSS<15 mg/L and NH(4)-N<1mg/L during the treatment of tomato processing wastewater with COD of 2800-15,500 mg/L, BOD(5) of 1750-7950 mg/L, TKN of 48-340 mg/L and NH(4)-N of 21-235 mg/L. Two treatment systems, a UASB-aerobic system and a UASB-anoxic-aerobic system were tested. Furthermore due to alkalinity deficiency, in the raw wastewater, the study explored varying UASB effluent recirculation flowrates to the UASB influent to reduce additional alkalinity requirements. The UASB-anoxic-aerobic system was effective in treating tomato canning wastewater at an overall HRT of 1.75 days while achieving 98.5% BOD(5), 95.6% COD, 84% TSS and 99.5% NH(4)-N removal producing effluent BOD(5), COD, TSS, NH(4)-N, TKN, NO(2)-N, NO(3)-N and PO(4)-P of 10, 70, 15, 0.5, 3, 0, 60 and 4 mg/L, respectively. The biogas yield was 0.43 m(3)/kg COD removed.  相似文献   

3.
Flood damage as a result of an extreme weather event is always a potential threat to constructed riparian wetlands in subtropical regions, and such damage can significantly impair the pollutant-removing performance of these wetlands The present study compares the pollutant-removal performance of the Hsin-Hai Bridge constructed wetland in the Tan-shui River basin of metropolitan Taipei in September 2000 (before the system was inundated by flood as a result of Typhoon Aere’) and in mid-October 2004 (after reconstruction of the wetland). The study analyses biochemical oxygen demand (BOD), ammonia nitrogen (NH4-N), and total phosphorus (TP) of influents and effluents in each of several compartments and for the system as a whole before the typhoon and after reconstruction. The study finds that performance with respect to BOD and NH4-N was marginally reduced (with no statistical significance) after reconstruction, but that performance with respect to TP was markedly improved (with statistical significance) after reconstruction. The study provides possible explanations for these findings and concludes that wetlands can be successfully reconstructed after extreme flood damage.  相似文献   

4.
Li L  Li Y  Biswas DK  Nian Y  Jiang G 《Bioresource technology》2008,99(6):1656-1663
Three parallel units of pilot-scale constructed wetlands (CWs), i.e., vertical subsurface flow (VSF), horizontal subsurface flow (HSF) and free water surface flow (FWS) wetland were experimented to assess their capabilities in purifying eutrophic water of Taihu Lake, China. Lake water was continuously pumped into the CWs at a hydraulic loading rate of 0.64 m d(-1) for each treatment. One year's performance displayed that average removal rates of chemical oxygen demand (COD), ammonia nitrogen (NH(4)(+)-N), nitrate nitrogen (NO(3)(-)-N), total nitrogen (TN) and total phosphorous (TP) were 17-40%, 23-46%, 34-65%, 20-52% and 35-66%, respectively. The VSF and HSF showed statistically similar high potential for nutrients removal except NH(4)(+)-N, with the former being 14% higher than that of the latter. However, the FWS wetland showed the least effect compared to the VSF and HSF at the high hydraulic loading rate. Mean effluent TP concentrations in VSF (0.056 mg L(-1)) and HSF (0.052 mg L(-1)) nearly reached Grade III (0.05 mg L(-1) for lakes and reserviors) water quality standard of China. Wetland plants (Typha angustifolia) grew well in the three CWs. We noted that plant uptake and storage were both important factors responsible for nitrogen and phosphorous removal in the three CWs. However, harvesting of the above ground biomass contributed 20% N and 57% P of the total N and P removed in FWS wetland, whereas it accounted for only 5% and 7% N, and 14% and 17% P of the total N and P removed in VSF and HSF CWs, respectively. Our findings suggest that the constructed wetlands could well treat the eutrophic lake waters in Taihu. If land limiting is considered, VSF and HSF are more appropriate than FWS under higher hydraulic loading rate.  相似文献   

5.
煤渣-草炭基质垂直流人工湿地系统对城市污水的净化效果   总被引:41,自引:3,他引:38  
垂直流人工湿地系统不但具有较高的水力负荷率(54—64cm.^-1),而且对有机物和N、P都具有较高的去除效果.其对化粪池出水中的COD、BOD5、NIA4^+-N和总P的去除率分别为76%--87%,88%--92%,75%--85%和77%--91%.处理出水中COD、BOD5、NH4^+-N和总P的平均浓度分别小于60、20、25和2.0mg.L^-1.植物种植试验结果表明,种植风车草可提高氨氮、总N和总P的去除率,分别为2%--3%、4%--6%、10%--14%.  相似文献   

6.
A laboratory study has been conducted to obtained preliminary process information of a suspended growth Predenitrification (SGPDN)system. System performance was evaluated, in terms of chemical oxygen demand (COD) removal, NH(3)-N removal, system biomass yield and inventory, and effluent qualities, at different solids retention times (SRTs) and recycle ratios. Chemical oxygen demand removal in an SGPDN system occurs mainly in the anoxic reactor, which accounts for 94% of total COD removal. The overall COD removal rate is independent of recycle ratio (ranging from 2-5) used in this study; however, effluent COD increase with increasing recycle ratio. The observed anoxic and aerobic COD removal rates decrease with increasing SRT. The NH(3)-N removal in an SGPDN system is induced by two mechanisms: assimilatory NH(3)-N requirement for biomass production in the anoxic reactor and nitrification in the aerobic reactor. The observed anoxic NH(3)-N removal rate relates directly to the anoxic COD removal rate and agrees fairly well with the assimilatory NH(3)-N requirement theoretically predicted. The overall NH(3)-N removal rate is independent of SRTs and recycle ratios used in this study. Biomass yield in an SGPDN system occurs mainly in the anoxic reactor. However, uniform distribution of biomass throughout the entire system is obtained because of the high recycle rate used. The observed biomass yield (Y(O)) decreases with increasing STR. Tertiary treatment efficiency can be achieved in an SGPDN system. More than 90% reduction in feed COD., feed NH(3)-N, and NO(2) + NO(3)-N is obtained at all SRTs and recycle ratios used in this study. Higher MLVSS loading rates can be applied to a final clarifier without impairing its separation efficiency because of the excellent settleability of the Predenitrification activated sludge.  相似文献   

7.
Considering the diversity and the unexplored potential of regional aquatic flora, this study aimed to identify and analyze the potential of native aquatic macrophytes to reduce the organic matter of dairy wastewater (DW) using experimental constructed wetlands. The dairy wastewater (DW) had an average chemical oxygen demand (COD) of 7414.63 mg/L and then was diluted to 3133.16 mg/L (D1) and to 2506.53 mg/L (D2). Total solids, COD, temperature, and pH analyses were performed, and the biochemical oxygen demand (BOD) was estimated from the COD values. The best performance in the reduction of the organic matter was observed for Polygonum sp. (87.5% COD and 79.6% BOD) and Eichhornia paniculata (90% COD and 83.7% BOD) at dilution D1, on the 8th day of the experiment. However, the highest total solids removal was observed for Polygonum sp. (32.2%), on the 4th day, at dilution D2. The total solid (TS) concentration has also increased starting from the 8th day of the experiment was observed which may have been due to the development of mosquito larvae and their mechanical removal by sieving, thus changing the steady state of the experimental systems. The macrophytes Polygonum sp. and E. paniculata were considered suitable for the reduction of organic matter of DW using constructed wetlands.  相似文献   

8.
This study set up two flow-through pilot-scale constructed wetlands with the same size but various flow patterns (free water surface flow (FWS) and subsurface flow (SSF)) to receive a nitrate-contaminated groundwater. The effects of hydraulic loading rate (HLR) on nitrate removal as well as the difference in performance between the various types of wetlands were investigated. Nitrate removal rates of both wetlands increased with increasing HLR until a maximum value was reached. The maximum removal rates, occurred at HLR of 0.12 and 0.07 m d(-1), were 0.910 and 1.161 g N m(-2)d(-1) for the FWS and SSF wetland, respectively. After the maximum values were reached, further increasing HLR led to a considerable decrease in nitrate removal rate. Nitrate removal efficiencies remained high (>85%) and effluent nitrate concentrations always satisfied drinking water standard (<10mg NO3-NL(-1)) when HLR did not exceed 0.04 m d(-1) for both FWS and SSF wetlands. The first-order nitrate removal rate constant tends to decrease with increasing HLRs. The FWS wetland provided significantly higher (p<0.05) organic carbon in effluent than the SSF wetland, while the SSF wetland exhibited significantly (p<0.05) lower effluent DO than the FWS wetland. However, there was no significant difference (p>0.05) in nitrate removal performance between the two types of constructed wetlands in this study except in one trial operating at HLR of 0.06-0.07 m d(-1).  相似文献   

9.
A laboratory scale rotating biological contactor (RBC) predenitrification system incorporating anoxic and aerobic units was evaluated for the treatment of settled high-strength municipal wastewater. The system was operated under four recycle ratios (1, 2, 3 and 4) and loading rates of 38-182 gCOD/m(2)d and 0.22-14 gOxid-N/m(2)d on the anoxic unit and 3.4-18 gCOD/m(2)d and 0.24-1.8 gNH(4)-N/m(2)d on the aerobic. The average removal efficiency in terms of chemical oxygen demand (COD), biochemical oxygen demand (BOD(5)), total suspended solids (TSS) and total nitrogen (Total-N) was 82%, 86%, 63% and 54%; settling of the RBC effluent increased COD and TSS removal to 94% and 97%. An increase in hydraulic loading resulting from higher recirculation, had limited negative effect on organic removal but improved nitrogen removal, and in terms of Total-N removal efficiency increased up to a ratio of 3 and then decreased.  相似文献   

10.
复合人工湿地对水禽污染废水的净化效果   总被引:1,自引:0,他引:1  
通过在北京市野生动物救护中心构建表流湿地与潜流湿地相结合的人工湿地来处理富营养化的水体,研究该人工湿地对TP、TN、浊度和CODcr的去除作用。研究表明:表流湿地对TP、TN、浊度和CODcr的去除率可分别达到68%,31%,93%和55%,潜流湿地对TP、TN、浊度和CODcr的去除率可分别达到75%,67%,55%和50%,复合人工湿地对TP、TN、浊度和CODcr的去除率可分别达到80%,50%,95%和90%,人工湿地不同构建类型对TP、TN的去除量没有显著差异(P>0.05),对TP的去除率、浊度和CODcr的去除量及去除率之间存在显著性差异(P<0.05),而对TN的去除率没有显著性差别(P>0.05),通过拟合进出水中不同污染物的质量浓度关系发现,表流湿地、潜流湿地和复合人工湿地进出水中TP、TN及CODcr之间存在显著的线性相关关系(P<0.05),相关系数分别为0.948、0.994、0.952,0.948、0.995、0.958和0.963、0.990、0.927,人工湿地进出水中浊度符合多项式方程规律,相关系数为分别为-0.523(R2=0.451,P>0.05),0.854(R2=0.8756,P<0.05)和-0.086(R2=0.197,P>0.05)。  相似文献   

11.
A horizontal subsurface flow (HSSF) and a free water surface flow (FWSF) constructed wetlands (4 m2 of each) were set up on the campus of Harran University, Sanliurfa, Turkey. The main objective of the research was to compare the performance of two systems to decide the better one for future planning of wastewater treatment system on the campus. Both of the wetland systems were planted with Phragmites australis and Canna indica. During the observation period (10 months), environmental conditions such as pH, temperature and total chemical oxygen demand (COD), soluble COD, total biochemical oxygen demand (BOD), soluble BOD, total suspended solids (TSS), total phosphate (TP), total nitrogen (TN) removal efficiencies of the systems were determined. According to the results, average yearly removal efficiencies for the HSSF and the FWSF, respectively, were as follows: total COD (75.7% and 69.9%), soluble COD (85.4% and 84.3%), total BOD (79.6% and 87.6%), soluble BOD (87.7% and 95.3%), TN (33.2% and 39.4%), and TP (31.5% and 6.5%). Soluble COD and BOD removal efficiencies of both systems increased gradually since the start-up. After nine months of operation, above 90% removal of organic matters were observed. The treatment performances of the HSSF were better than that of the FWSF with regard to the removal of suspended solids and total COD at especially high temperatures. In FWSF systems, COD concentrations extremely exceeded the discharge limit values due to high concentrations of algae in spring months.The performance of the two systems was modelled using an artificial neural network-back-propagation algorithm. The ANN model was competent at providing reasonable match between the measured and the predicted concentrations of total COD (R = 0.90 for HSSF and R = 0.96 for FWSF), soluble COD (R = 0.90 for HSSF and R = 0.74 for FWSF) and total BOD (R = 0.94 for HSSF and R = 0.84 for FWSF) in the effluents of constructed wetlands.  相似文献   

12.
Nine filter beds have been constructed in the Nordic countries, Denmark, Finland, Norway and Sweden. Filter beds consist of a septic tank followed by an aerobic pre-treatment biofilter and a subsequent saturated flow grass-covered filter. Thus, filter beds are similar to subsurface flow constructed wetlands with pre-treatment biofilters, but do not have wetland plants with roots submerged into the saturated filter. All saturated filters contain Filtralite®P, a light-weight expanded clay aggregate possessing high phosphorus sorption capacity. The filter bed systems showed stable and consistent performance during the testing period of 3 years. Removal of organic matter measured as biochemical oxygen demand (BOD) was >80%, total phosphorus (TP) >94% and total nitrogen (TN) ranged from 32 to 66%. Effluent concentrations of fecal indicator bacteria met the European bathing water quality criteria in all systems. One system was investigated for virus removal and somatic viruses were not detected in the effluent. The investigations revealed that the majority of the BOD and nitrogen removal occurred in the pre-treatment filters and the phosphorus and bacteria removal was more prominent in the saturated filters. The saturated filters could be built substantially smaller than the current design guidelines without sacrificing treatment performance. The used filter material met the Norwegian regulations for reuse in agriculture with respect to heavy metals, bacteria and parasites. When saturated with phosphorus, the light-weight aggregate, Filtralite®P used in the saturated bed is a suitable phosphorus fertilizer and additionally has a liming effect.  相似文献   

13.
Purification of nitrate-rich agricultural runoff by a hydroponic system   总被引:2,自引:0,他引:2  
Yang Z  Zheng S  Chen J  Sun M 《Bioresource technology》2008,99(17):8049-8053
The purification of nitrate-rich agricultural runoff by a floating-raft (FR) hydroponic system was investigated at 3-, 2- and 1-d hydraulic retention times (HRTs) with particular emphasis on nitrogen conversion and removal through the system. The FR system has a dissolved oxygen (DO) environment similar to the horizontal subsurface flow system, generally 0.00mgL(-1), that facilitates denitrification. An efficient nitrate-nitrite-nitrogen (NO(x)-N) removal, 91%, 97% and 71% on average at 3-, 2- and 1-d HRT, respectively, was frequently achieved. The mean retentions were 17-47% for chemical oxygen demand, 31-64% for total nitrogen, and 8-15% for total phosphorus for the FR system. Mass balance analysis implied that the detectable DO concentration in the reactor, as low as 0.7mgL(-1), played a very important role in the conversion and removal of NH(3)-N and NO(x)-N, which finally affected the NO(x)-N removal at 3-d HRT.  相似文献   

14.
【背景】低碳氮比生活污水很难达标处理,多级A/O工艺、生物强化技术及生物膜技术的有机结合可有效解决这一问题。【目的】开发出一种泥膜共生多级A/O工艺并进行中试研究,驯化出高效脱氮除磷菌剂并对系统进行生物强化。【方法】通过测定中试设备出水及污水处理厂出水化学需氧量(Chemical oxygen demand,COD)、氨氮(NH_4~+-N)、硝氮(NO_3~--N)、总氮(Total nitrogen,TN)、总磷(Total phosphorus,TP)对比分析两种工艺的污染物去除效能,利用高通量测序技术对比生物强化技术对系统微生物群落结构的影响。【结果】中试设备对COD、NH_4~+-N、NO_3~--N、TN、TP的去除效果均优于污水处理厂的处理工艺;驯化的低温好氧反硝化菌TN去除率最大值可达84.21%,驯化的低温反硝化聚磷菌群对磷的去除率最高可达85.75%;利用驯化菌群对中试设备进行生物强化后较好地改善了系统NH_4~+-N、NO_3~--N、TN、TP的去除效果;经生物强化后,具有好氧反硝化和反硝化聚磷功能的Pseudomonas菌群明显增多。【结论】泥膜共生多级A/O工艺对于低碳氮比生活污水的处理具有很好的效果,利用生物强化技术可有效提高低温条件下系统污染物去除效能。  相似文献   

15.
A pilot-scale multilayer rapid infiltration system (MRIS) for domestic wastewater treatment was established and efficient removal of ammonia and chemical oxygen demand (COD) was achieved in this study. The microbial community composition and abundance of ammonia oxidizers were investigated. Efficient biofilms of ammonia oxidizers in the stationary phase (packing material) was formed successfully in the MRIS without special inoculation. DGGE and phylogenetic analyses revealed that proteobacteria dominated in the MRIS. Relative abundance of ammonia-oxidizing archaea (AOA) and ammonia-oxidizing bacteria (AOB) showed contrary tendency. In the flowing phase (water effluent), AOA diversity was significantly correlated with the concentration of dissolve oxygen (DO), NO3-N and NH3-N. AOB abundance was significantly correlated with the concentration of DO and chemical oxygen demand (COD). NH3-N and COD were identified as the key factors to shape AOB community structure, while no variable significantly correlated with that of AOA. AOA might play an important role in the MRIS. This study could reveal key environmental factors affecting the community composition and abundance of ammonia oxidizers in the MRIS.  相似文献   

16.
With the rapid development of scaled anaerobic digestion of pig manure, the generation of liquid anaerobic digestate exceeds the farmland loading capacity, causing serious environmental pollution. Three laboratory‐scale horizontal subsurface flow constructed wetlands (CWs; planted + aeration, planted, and unplanted) were set up to investigate the feasibility of liquid digestate treatment in wetlands. Treatment capacity in different wetlands was evaluated under different influent concentrations (chemical oxygen demand [COD], 5 days biochemical oxygen demand [BOD5], and nitrogen forms). The effect of aeration and effluent recirculation on organic matter and total nitrogen removal was investigated. Results showed that integrating intermittent aeration in CWs significantly improved the oxygen condition (p < 0.01) in the wetland bed and promoted BOD5 removal to 90% in aerated CWs as compared with <15% in the unaerated CWs. Meanwhile, COD removal between these three wetlands did not show any difference and varied from 52 to 72% under influent concentration of 200–820 mg/L because of the high content of hard‐degradable organic matter in the liquid digestate. Intermittent aeration resulted in high ammonium removal (>98%) although the influent loading varied from 65 to 350 mg/L. However, intermittent aeration caused nitrate accumulation of 300 mg/L and limited total nitrogen (TN) removal of 33%. To intensify the TN removal, we verified effluent recirculation to increase the removal efficiency of TN to 78%. These results not only show the potential application of CWs for treatment of high‐strength liquid anaerobic digested slurry, but also indicate the significance of intermittent aeration on the enhanced removal of organic matter and ammonium.  相似文献   

17.
Different start-up procedures of an upflow anaerobic sludge bed (UASB) digester were carried out. Start-up without inoculum (experiment A) was delayed for about 120 day. The digester reached 75-85% total suspended solids (TSS) removal, 54-58% total chemical oxygen demand (TCOD) removal and 63-73% biological oxygen demand (BOD5) removal at influent concentrations of 240-340 mg TCODil-1, temperatures of 13.5-15 degrees C and hydraulic retention times (HRT) of 10-11 h. Digested sludge was used as inoculum in experiment B. After the start-up period of 75 days, digester efficiencies were 58%, 41% and 54% for TSS, TCOD and BOD5 removal, respectively, working at 169 mg TCODil-1, temperature of 14 degrees C and HRT of 11 h. The sludge bed developed and stabilised quickly when using a hydraulically adapted inoculum (experiment C), but TCOD and BOD5 removals remained low and volatile fatty acids (VFA) accumulated in the effluent.  相似文献   

18.
Pilot-scale surface-flow (SF), subsurface-flow (SSF), and floating aquatic plant (FAP) constructed wetland system designs were installed and evaluated to determine the effectiveness of constructed wetlands to treat tertiary effluent wastewater in a Midwestern U.S. climate (central Illinois). Average ammonia-nitrogen (N) concentrations decreased approximately 50% in the SSF system design, suggesting that this design had the highest nitrification rate. Nitrate-N concentrations decreased by over 60% in the FAP system design, possibly due to dissimilatory reduction or plant uptake. Total phosphorus (P) concentration reductions of 25 to 40% were observed in all three system designs. Five-day biochemical oxygen demand (BOD5) and dissolved oxygen (DO) results suggested that biodegradation was highest in the SSF system design and lowest in the FAP system design. Greater than 90% concentration reductions of total coliform and E. coli recovered were also observed following treatment in all three system designs. The FAP system design appeared to yield the highest concentration reduction efficiency for E. coli, possibly due to increased sunlight and related bacteriocidal ultraviolet light exposure. Ongoing experiments will test regularly for a variety of vegetative, water quality, and biological conditions for longer time periods in order to gain a better understanding of the pilot constructed wetland system design kinetics.  相似文献   

19.
The aim of the present study is to probe the relation between plant growth and its decontamination effect in constructed wetlands.Four species were studied in the small-scale mono-cuitured constructed wetlands, which were fed with domestic wastewater. Plant growth indexes were correlated with contaminant removal performance of the constructed wetlands. Wetlands planted with Cyperus flabelliformis Rottb. showed the highest growth indexes such as shoot growth, biomass, root activity, root biomass increment, and the highest contaminant removal rates, whereas wetlands planted with Vetiveria zizanioides L. Nash had the lowest growth indexes and the lowest removal rates. Above-ground biomass and total biomass were significantly correlated with ammonia nitrogen removal, and below-ground biomass with soluble reactive phosphorus removal. Photosynthetic rate had higher correlation with nitrogen removal in these species. Root activity and root biomass increment was more correlated with 5 d biochemical oxygen demand removal.Chemical oxygen demand removal had lower correlations with plant growth indexes. All four species had higher removal rates in summer and autumn. The results suggest that the effect of plant growth on contaminant removal in constructed wetlands were different specifically in plants and contaminants.  相似文献   

20.
Experiments were conducted to investigate the feasibility of applying constructed wetlands to treat a sanitary landfill leachate containing high nitrogen and bacterial contents. Under a tropical condition (temperature of about 30 degrees C), the constructed wetland units operating at the hydraulic retention time of 8d yielded the best treatment efficiencies with BOD(5), TN and fecal coliforms removal of 91%, 96% and more than 99%, respectively. Cadmium removal in the SFCW bed was 99.7%. Mass balance analysis, based on total nitrogen contents of the plant biomass and dissolved oxygen and oxidation-reduction potential values, suggested that 88% of the input total nitrogen were uptaken by the plant biomass. Fluorescence in situ hybridization results revealed the predominance of bacteria, including heterotrophic and autotrophic, responsible for BOD(5) removal. Nitrifying bacteria was not present in the constructed wetland beds.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号