The protein content of fresh homogenates and their corresponding TCA precipitated fractions of 10 different species of helminths was estimated by the methods of Lowry et al. and Spector using the Folin phenol reagent and Coomassie brilliant blue G-250 respectively. The former method gives exaggerated values as compared to the latter method. The parasite phenols, phenolic proteins and catecholamines could be responsible for interference in the Lowry's procedure. The TCA noln-precipitable moieties also give colour only with the Folin phenol assay. The pronounced intra-specific differences in the total protein content of helminths reflect their metabolic variations and adaptations. Habitat does not appear to influence the protein content of parasites, however, the effect of host variation was evident in the pouched amphistome G. crumenifer. It is concluded that the dye binding method gives more consistent results and it can be conveniently applied to crude tissue homogenates of helminths.  相似文献   

2.
1. A simple colorimetric assay for UDP-glucuronosyltransferase activities towards phenolic substrates, using Folin & Ciocalteu's phenol reagent, is described. The assay is used to measure rat liver transferase activities towards substrates from a series of 4-alkyl-substituted phenols. 2. Activities towards phenol, 4-methylphenol and 4-ethylphenol develop near-adult values before birth, are precociously stimulated by dexa methasone in utero and are stimulated 3--4-fold by 3-methylcholanthrene in adult liver. These are assigned to a "late-foetal" group of transferase activities. 3. Activities towards 4-n-propylphenol, 4-s-butylphenol and 4-t-butylphenol are negligible in late-foetal liver, developing to near-adult values in the first 4 postnatal days, and are not affected by dexamethasone or 3-methylcholanthrene. They are assigned to a "neonatal" group of transferase activities. 4. Although 4-ethylphenol and 4-n-propylphenol differ only by a single --CH2-- moiety, this is sufficient to change the acceptability of these substrates respectively from the late-foetal to the neonatal group of transferase activities. The change is distinct, with no overlapping of substrate acceptability between the two groups of transferase activities. 5. From consideration of the above and other substrates, the two groups of transferase activities do not distinguish substrates on the basis of their molecular weights or lipophilicity. The distinguishing feature appears to be the specific molecular configurations of the substrates.  相似文献   

3.
A new colorimetric technique for the estimation of ascorbic acid by using Folin phenol reagent has been developed. The absorption maximum of the color developed by the interaction of ascorbic acid with Folin reagent is 760 nm. The technique obeys the Beer-Lambert law up to a concentration of 45 μg ascorbic acid as shown by the standard curve. The color developed has been found to be stable up to 18 h. Recovery experiments showed that the technique is almost 100% efficient. The development of the color is not obstructed by glucose, glutathione, bovine serum albumin, urea, cysteine, adenine, guanine, cytosine, uracil, sulfosalicylic acid, thymol, or oxyhemoglobin, which are compounds suspected of interfering in routine analysis. The technique is simple, quick, and efficient and can be employed for the estimation of ascorbic acid in a wide variety of biological materials.  相似文献   

4.
A collaborative study was conducted to establish a suitable international reference reagent for hepatitis B vaccine for use in immunogenicity assays. The limiting dilution required to induce antibodies in 50% of the test animals was determined for the proposed international reference reagent and three other plasma-derived hepatitis B vaccines. The minimum antigenic dose of these preparations varied widely (100-fold range) between laboratories. However, the expression of potencies of vaccines relative to the proposed International Reference Reagent reduced the variation between laboratories to within a 10-fold range. The reference reagent is intended for use in assays of hepatitis B vaccines in mouse (or guinea-pig) immunogenicity studies. For products made by different procedures, clinical trials in humans are necessary to establish a correlation between the immunogenic potency in animals and man.  相似文献   

5.
The Lowry protein assay was directly adapted for use on the Cobas-Bio centrifugal analyzer resulting in a 50% reduction of the coefficients of variation of the manual method. It was also demonstrated that the reaction need not be pursued to its endpoint and that absorbance readings taken immediately after the addition of the Folin reagent were directly related to the protein concentration. Thus the total assay time could be reduced from 30 to 3 min with no loss of accuracy or reproducibility.  相似文献   

6.
This paper describes a method for the quantitative analysis of solutions containing a mixture of proteins and sulfobetaine. In a preliminary step the proteins, which interfere with the detergent assay, are separated by precipitation with trichloroacetic acid (8%). The insoluble fraction, dissolved in NaOH (1.0 n), and the soluble fraction, containing the detergent, are treated with the Folin-Ciocalteu phenol reagent, essentially following the method of O. H. Lowry, N. J. Rosebrough, A. L. Farr, and R. J. Randall (1951, J. Biol. Chem.193, 265–275). The absorbance of the protein fraction is read, as usual at 750 nm, while that of the detergent solution is read at 342 nm. At this wavelength, sulfobetaine, treated with the Folin reagent, absorbs strongly, the absorbance being proportional to its concentration up to 1.5 mg/ml.  相似文献   

7.
Nelson’s arsenomolybdate, the chromogenic reagent in Somogyi–Nelson method, was replaced by Folin–Ciocalteu phenol reagent. The major object was to remove the toxic arsenic compounds from the color reaction system. The color-producing ability of the phenol reagent was considerably lower than that of Nelson’s reagent. However, the modified method was favorably comparable to Somogyi–Nelson method in simplicity, reproducibility and stability of color development. The error in both the modified and Somogyi–Nelson method could be reduced to about one fourth by adding sodium benzoate (final concentration, about 0.5%) to the test solutions.  相似文献   

8.
Antibody to hepatitis B virus core antigen (anti-HBc) is one of the most important serological markers during hepatitis B virus (HBV) infection. The quality of the hepatitis B virus core antigen (HBcAg; diagnostic antigen) is crucial to the accuracy of anti-HBc detection. In an attempt to explore the suitability of recombinant HBcAg (rHBcAg) for diagnostic purposes, HBcAg was expressed in Escherichia coli (E. coli) and Pichia pastoris (P. pastoris) and evaluated for the detection of anti-HBc. The expression level of the recombinant protein satisfied the criteria for large-scale biologic production. P. pastoris- and E. coli-derived rHBcAg were purified with gel filtration followed by sucrose gradient (reagents A and C) or with a monoclonal anti-HBc antibody binding (reagents B and D) and were utilized to detect anti-HBc in competitive inhibition enzyme-linked immunosorbent assay (ELISA) format. The ELISA using P. pastoris-derived rHBcAg had a higher specificity and sensitivity than that using E.coli-derived rHBcAg to detect the anti-HBc standard panel. Serum specimens were collected from HBV-infected patients and healthy individuals (voluntary blood donors). Anti-HBc was detected in those specimens using P. pastoris- and E. coli-derived rHBcAg. The positive rate of anti-HBc detection in HBV-infected patients' sera was 100% with reagents A and B, 96.4% with reagent C, and 93.6% with reagent D. The negative rate in healthy control sera was 100% with reagents A and B, 97.0% with reagent C, and 99.7% with reagent D. These data indicate that P. pastoris-derived rHBcAg is superior to E.coli-derived rHBcAg for the detection of anti-HBc using the diagnostic ELISA.  相似文献   

9.
Folin and Ciocalteu's phenol reagent may be reduced by a variety of compounds, which therefore interfere with the Lowry method of protein determination (1,2). Peters and Fouts (3) reported that two of the zwitterionic biological buffers described by Good et al. (4) reacted strongly with the Folin reagent and thus seriously interfered with protein determinations. The zwitterionic buffers have many properties which lead to their use in biological work, where protein estimations will be required. Since the publication of Good et al. (4), the range of zwitterionic buffers has been increased. The possibility that these other buffers may also produce artefacts has therefore been investigated.  相似文献   

10.
The Lowry method for quantitation of protein was adapted to automated flow injection analysis. The procedure was developed using two different pure proteins: bovine serum albumin and hepatitis B surface antigen. The system was optimized for reagent concentration, pH, gain, temperature, sample volume, and output. The response of each protein was affected differently by temperature. The reaction slopes and absorbance values of the proteins were similar at 90 degrees C to allow quantitation of hepatitis surface antigen against bovine serum albumin. Advantages of the automated flow injection analysis Lowry procedure include: rapid analyses (90 samples/h), small sample volume (30 microliters, 100 microliters), fast response (20 s), reproducibility (less than or equal to 2% CV within an assay and 3 to 6% CV among assays), sensitivity (5 micrograms), and high correlation (99.8%) with manual assay. After a 30-min set-up period, the analyzer was available to assay protein on demand throughout the day, making it suitable for process and quality control testing.  相似文献   

11.
乙肝病毒S蛋白是病毒的包膜蛋白,与病毒进入细胞有关,它存在逆转录过程并且具有极强的潜伏性。本论文应用生物信息学分析乙肝病毒S蛋白的序列特征,利用在线分析软件预测乙肝病毒S蛋白的理化性质和亲疏水性、跨膜区域、信号肽特征、磷酸化位点、二级结构以及乙肝病毒S蛋白的最佳抗原表位形成位置等。结果显示了乙肝病毒S蛋白由226个氨基酸组成,理论等电点是8.21,为不稳定蛋白,总平均亲水性为0.649,是疏水蛋白质,并且该蛋白存在信号肽,有4个跨膜区,有30个潜在的磷酸化位点,主要二级结构为α螺旋和无规则卷曲,同时,结合乙型肝炎病毒S蛋白的序列可及性、线性表位、β转角、柔性、抗原性的预测结果,可以找到潜在的抗原表位区域,为乙型肝炎的表位疫苗研制提供重要的参考依据,有利于进一步对乙型肝炎S蛋白的抗原性进行研究。  相似文献   

12.
Phenol has been added to the Coomassie Brilliant Blue G-250 dye reagent used in the standard Bradford protein assay and its effect upon the reagent blank and assay response of fourteen proteins investigated. Phenol can enhance or impair colour yield depending upon its concentration and the amount and type of protein assayed. Four characteristic protein responses to increasing assay concentrations of phenol have been observed. These indicate a complex influence of phenol upon the protein assay. Dye reagent containing 0.5% phenol gave optimal colour yield with most of the proteins investigated and an improved assay response of ovalbumin, ribonuclease, lysozyme, insulin, pepsin and chymotrypsinogen-A relative to bovine albumin.  相似文献   

13.
Despite reports of its susceptibility to various interfering factors, the Folin Phenol protein quantification method of O. H. Lowry, N. J. Rosebrough, A. L. Farr, and R. J. Randall (1951, J. Biol. Chem. 193, 265–275) remains the most convenient and accurate method for routine protein determinations. Our findings indicate that the Lowry assay is also photosensitive which can result in a discrepancy of up to 10% in estimated protein concentrations, unless appropriate precautions are taken.  相似文献   

14.
A comparison of four methods for the determination of total proteins is presented from the following points of view: - sensitivity; - specificity; - amount of work, chemicals, time and equipment needed for the performance of the determination. The following tests have been examined; Tombs' (absorbancy at 210 nm); Waddell's (difference in absorbancy between 215 and 225 nm); Warburg's (absorbancy at 280 nm); Lowry's (absorbancy at 500 nm after the reaction with phenol reagent). The authors recommend Tombs' method for its outstanding sensitivity, specificity and simplicity as the best of the four.  相似文献   

15.
Antibody to hepatitis B surface antigen (HBsAb) is the important serological marker of the hepatitis B virus (HBV) infection. Conventionally, the hepatitis B surface antigen (HBsAg) obtained from the plasma of HBV carriers is used as the diagnostic antigen for detection of HBsAb. This blood-origin antigen has some disadvantages involved in high cost, over-elaborate preparation, risk of infection, et al. In an attempt to explore the suitable recombinant HBsAg for the diagnostic purpose, the HBV S gene was expressed in Pichia pastoris and the product was applied for detection of HBsAb. Hepatitis B virus S gene was inserted into the yeast vector and the expressed product was analyzed by sodium dodecyl sulphate polyacrolamide gel electrophoresis (SDS-PAGE), immunoblot, electronic microscope and enzyme linked immunosorbent assay (ELISA). The preparations of synthesized S protein were applied to detect HBsAb by sandwich ELISA. The S gene encoding the 226 amino acid of HBsAg carrying a hexa-histidine tag at C terminus was successfully expressed in Pichia pastoris. The His-Tagged S protein in this strain was expressed at a level of about 14.5 % of total cell protein. Immunoblot showed the recombinant HBsAg recognized by monoclonal HBsAb and there was no cross reaction between all proteins from the host and normal sera. HBsAb detection indicated that the sensitivity reached 10 mIu (micro international unit)/ml and the specificity was 100 % with HBsAb standard of National Center for Clinical Laboratories. A total of 293 random sera were assayed using recombinant S protein and a commercial HBsAb ELISA kit (produced by blood-origin HBsAg), 35 HBsAb positive sera and 258 HBsAb negative sera were examined. The same results were obtained with two different reagents and there was no significant difference in the value of S/CO between the two reagents. The recombinant HBV S protein with good immunoreactivity and specificity was successfully expressed in Pichia pastoris. The reagent for HBsAb detection prepared by Pichia pastoris-derived S protein showed high sensitivity and specificity for detection of HBsAb standard. And a good correlation was obtained between the reagent produced by recombinant S protein and commercial kit produced by blood-origin HBsAg in random samples.  相似文献   

16.
DPT, a combination vaccine against diphtheria, tetanus and pertussis is available since many years and still continued in the national immunisation schedule of many countries. Although highly potent, reactions to DPT vaccine are well known, mainly attributed to the factors like Pertussis component, aluminum adjuvant and lower purity of tetanus and diphtheria toxoids. The latter most important aspect has become a matter of concern, specially for the preparation of next generation combination vaccines with more number of antigens in combination with DPT.Purity of toxoid is expressed as Lf (Limes flocculation) per mg of protein nitrogen. The Kjeldahl method (KM) of protein nitrogen estimation suggested by WHO and British Pharmacopoeia is time consuming and less specific. Need has been felt to explore an alternative method which is quick and more specific for toxoid protein determination. DC (detergent compatible) protein assay, an improved Lowry's method, has been found to be much more advantageous than Kjeldahl method.  相似文献   

17.
Blood plasma and cerebrospinal fluid (CSF) samples were collected from adult female rabbits (New Zealand White), newborn, and embryos at 18, 20, 24, and 28 days of gestation. Samples were analyzed for total protein using the Folin phenol reagent. During development, mean total protein of blood plasma rose sharply from 12.45 to 12.51 mg/ml at 18 to 20 days to 37.56 mg/ml at 28 days. Levels further increased to 54.06 mg/ml in the newborn and to 66.18 mg/ml in the adult. The protein concentration of cerebrospinal fluid was constant at 5.20 to 5.29 mg/ml between 18 and 20 days of gestation, but steadily decreased to 3.53 mg/ml at 28 days. By birth, the CSF protein concentration was further reduced to 2.08 mg/ml, and this level differed only slightly (P < 0.05) from CSF protein values determined for adults. These data indicate that the blood-cerebrospinal fluid barrier to proteins begins to function by 18 to 20 days of gestation, and the protein concentration of cerebrospinal fluid approaches the normal adult value soon after birth.  相似文献   

18.
On the chemical basis of the Lowry protein determination   总被引:1,自引:0,他引:1  
The copper-catalyzed oxidation of peptides and proteins by phosphomolybdic/phosphotungstic acid (Folin phenol reagent) was studied with respect to redox stoichiometry of color formation and nature of the oxidation products. From peptides without reducing side chains two reducing equivalents were transferred under ideal conditions to Mo6+/W6+ for each unit of tetradentate copper complex with concomitant formation of an imino peptide. Tyrosine and tryptophan side chains contributed four additional reducing equivalents. Oxidation of proline-containing peptides was greatly impaired as judged from color formation due to the interference of the imino acid with complex formation. Reaction of the oxidized peptides with 2,4-dinitrophenyl (DNP)-hydrazine gave a peptide amine and the DNP-hydrazone of a 2-oxoacyl peptide. The oxidation products from tetraalanine were identified as dialanine amide and pyruvoylalanine DNP-hydrazone. From the time course of the development of the blue color on reduction of Folin reagent with tetraalanine it was inferred that the reaction consisted of an initial (less than 5 s) oxidation to a Cu3+ peptide complex followed by slow changes in absorbance, especially above 0.2 mM. Due to these complications the two-electron stoichiometry has to be considered only as a limiting case for peptide concentrations below 0.02 mM.  相似文献   

19.
Interaction between preformed nucleocapsids and viral envelope proteins is critical for the assembly of virus particles in infected cells. The pre-S1 and pre-S2 and cytosolic regions of the human hepatitis B virus envelope protein had been implicated in the interaction with the core protein of nucleocapsids. The binding affinities of specific subdomains of the envelope protein to the core protein were quantitatively measured by both ELISA and BIAcore assay. While a marginal binding was detected with the pre-S1 or pre-S2, the core protein showed high affinities to pre-S with apparent dissociation constants (K(D)(app)) of 7.3+/-0.9 and 8.2+/-0.4microM by ELISA and BIAcore assay, respectively. The circular dichroism analysis suggested that conformational change occurs in pre-S through interaction with core protein. These results substantiate the importance of specific envelope domains in virion assembly, and demonstrate that the interaction between viral proteins can be quantitatively measured in vitro.  相似文献   

20.
We report here substantial interference from N-hydroxysuccinimide (NHS) in the bicinchoninic acid (BCA) protein assay. NHS is one of the most commonly used crosslinking agents in bioanalytical sciences, which can lead to serious potential errors in the BCA protein assay based protein estimation if it is present in the protein analyte solution. It was identified to be a reducing substance, which interferes with the BCA protein assay by reducing Cu2+ in the BCA working reagent. The absorbance peak and absorbance signal of NHS were very similar to those of bovine serum albumin (BSA), thereby indicating a similar BCA reaction mechanism for NHS and protein. However, the combined absorbance of NHS and BSA was not additive. The time–response measurements of the BCA protein assay showed consistent single-phase kinetics for NHS and gradually decreasing kinetics for BSA. The error in protein estimation due to the presence of NHS was counteracted effectively by plotting additional BCA standard curve for BSA with a fixed concentration of NHS. The difference between the absorbance values of BSA and BSA with a fixed NHS concentration provided the absorbance contributed by NHS, which was then subtracted from the total absorbance of analyte sample to determine the actual absorbance of protein in the analyte sample.  相似文献   