首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We have studied the effects of aerosolized substance P (SP) in guinea pigs with reference to lung resistance and dynamic compliance changes and their recovery after hyperinflation. In addition, we have examined the concomitant formation of airway microvascular leakage and lung edema. Increasing breaths of SP (1.5 mg/ml, 1.1 mM), methacholine (0.15 mg/ml, 0.76 mM), or 0.9% saline were administered to tracheostomized and mechanically ventilated guinea pigs. Lung resistance (RL) increased dose dependently with a maximum effect of 963 +/- 85% of baseline values (mean +/- SE) after SP (60 breaths) and 1,388 +/- 357% after methacholine (60 breaths). After repeated hyperinflations, methacholine-treated animals returned to baseline, but after SP, mean RL was still raised (292 +/- 37%; P less than 0.005). Airway microvascular leakage, measured by extravasation of Evans Blue dye, occurred in the brain bronchi and intrapulmonary airways after SP but not after methacholine. There was a significant correlation between RL after hyperinflation and Evans Blue dye extravasation in intrapulmonary airways (distal: r = 0.89, P less than 0.005; proximal: r = 0.85, P less than 0.01). Examination of frozen sections for peribronchial and perivascular cuffs of edema and for alveolar flooding showed significant degrees of pulmonary edema for animals treated with SP compared with those treated with methacholine or saline. We conclude that the inability of hyperinflation to fully reverse changes in RL after SP may be due to the formation of both airway and pulmonary edema, which may also contribute to the deterioration in RL.  相似文献   

2.
In this study we have investigated how changes in respiratory frequency and tidal volume in anesthetized dogs affect the fall in dynamic compliance (Cdyn) that occurs with time after a hyperinflation. Results showed that increasing frequency [at controlled arterial (PaCO2)] PCO2 from 16 to 32 breaths/min had no effect on either the rate of fall or the magnitude of the fall up to 1 h after the hyperinflation. However, increasing the tidal volume from 300 to 750 ml abolished the fall in Cdyn from 10 to 50 min after the hyperinflation; the fall within the first 10 min remained unchanged. We also examined the effect of a simulated "hyperinflation" on the compliance of strips of parenchymal tissue in vitro. This result indicated that in the absence of surface forces, parenchymal tissue demonstrates a fall in compliance, which is complete within 10 min. Overall our findings are consistent with the hypothesis that the fall in Cdyn after hyperinflation is a two-phase process. The initial rapid fall in Cdyn (i.e., within 10 min) may simply represent a passive recovery process from the hyperinflation stress on the parenchymal tissue. The slower fall occurring after 10 min likely results from progressive increases in surface tension, and this increase can apparently be blocked by increases in tidal volume.  相似文献   

3.
Infants with respiratory failure are frequently mechanically ventilated at rates exceeding 60 breaths/min. We analyzed the effect of ventilatory rates of 30, 60, and 90 breaths/min (inspiratory times of 0.6, 0.3, and 0.2 s, respectively) on the pressure-flow relationships of the lungs of anesthetized paralyzed rabbits after saline lavage. Tidal volume and functional residual capacity were maintained constant. We computed effective inspiratory and expiratory resistance and compliance of the lungs by dividing changes in transpulmonary pressure into resistive and elastic components with a multiple linear regression. We found that mean pulmonary resistance was lower at higher ventilatory rates, while pulmonary compliance was independent of ventilatory rate. The transpulmonary pressure developed by the ventilator during inspiration approximated a linear ramp. Gas flow became constant and the pressure-volume relationship linear during the last portion of inspiration. Even at a ventilatory rate of 90 breaths/min, 28-56% of the tidal volume was delivered with a constant inspiratory flow. Our findings are consistent with the model of Bates et al. (J. Appl. Physiol. 58: 1840-1848, 1985), wherein the distribution of gas flow within the lungs depends predominantly on resistive factors while inspiratory flow is increasing, and on elastic factors while inspiratory flow is constant. This dynamic behavior of the surfactant-depleted lungs suggests that, even with very short inspiratory times, distribution of gas flow within the lungs is in large part determined by elastic factors. Unless the inspiratory time is further shortened, gas flow may be directed to areas of increased resistance, resulting in hyperinflation and barotrauma.  相似文献   

4.
Deep-breath frequency has been shown to increase in spontaneously obstructed asthmatic subjects. Furthermore, deep breaths are known to be regulated by lung rapidly adapting receptors, yet the mechanism by which these receptors are stimulated is unclear. This study tested the hypothesis that deep-breath frequency increases during experimentally induced bronchoconstriction, and the magnitude of the increased deep-breath frequency is dependent on the method by which bronchoconstriction is induced. Nine cynomolgus monkeys (Macaca fascicularis) were challenged with methacholine (MCh), Ascaris suum (AS), histamine, or an external mechanical resistance. Baseline (BL) and challenge deep-breath frequency were calculated from the number of deep breaths per trial period. Airway resistance (Raw) and tissue compliance (Cti), as well as tidal volume, respiratory rate, and minute ventilation, were analyzed for BL and challenged conditions. Transfer impedance measurements were fit with the DuBois model to determine the respiratory parameters (Raw and Cti). The flow at the airway opening was measured and analyzed on a breath-by-breath basis to obtain the ventilatory parameters (tidal volume, respiratory rate, and minute ventilation). Deep-breath frequency resulting from AS and histamine challenges [0.370 (SD 0.186) and 0.467 breaths/min (SD 0.216), respectively] was significantly increased compared with BL, MCh, or external resistance challenges [0.61 (SD 0.046), 0.156 (SD 0.173), and 0.117 breaths/min (SD 0.082), respectively]. MCh and external resistance challenges resulted in insignificant changes in deep-breath frequency compared with BL. All four modalities produced similar levels of bronchoconstriction, as assessed through changes in Raw and Cti, and had similar effects on the ventilatory parameters except that non-deep-breath tidal volume was decreased in AS and histamine. We propose that increased deep-breath frequency during AS and histamine challenge is the result of increased vascular permeability, which acts to increase rapidly adapting receptor activity.  相似文献   

5.
Mice have been widely used in immunologic and other research to study the influence of different diseases on the lungs. However, the respiratory mechanical properties of the mouse are not clear. This study extended the methodology of measuring respiratory mechanics of anesthetized rats and guinea pigs and applied it to the mouse. First, we performed static pressure-volume and maximal expiratory flow-volume curves in 10 anesthetized paralyzed C57BL/6 mice. Second, in 10 mice, we measured dynamic respiratory compliance, forced expiratory volume in 0.1 s, and maximal expiratory flow before and after methacholine challenge. Averaged total lung capacity and functional residual capacity were 1.05 +/- 0.04 and 0.25 +/- 0.01 ml, respectively, in 20 mice weighing 22.2 +/- 0.4 g. The chest wall was very compliant. In terms of vital capacity (VC) per second, maximal expiratory flow values were 13.5, 8.0, and 2.8 VC/s at 75, 50, and 25% VC, respectively. Maximal flow-static pressure curves were relatively linear up to pressure equal to 9 cm H(2)O. In addition, methacholine challenge caused significant decreases in respiratory compliance, forced expiratory volume in 0.1 s, and maximal expiratory flow, indicating marked airway constriction. We conclude that respiratory mechanical parameters of mice (after normalization with body weight) are similar to those of guinea pigs and rats and that forced expiratory maneuver is a useful technique to detect airway constriction in this species.  相似文献   

6.
Hubmayr, Rolf D., and Susan S. Margulies. Regionalventilation in statically and dynamically hyperinflated dogs.J. Appl. Physiol. 81(4):1815-1821, 1996.Using the parenchymal marker technique innormal anesthetized dogs, we compared the dynamics of regional lungexpansion between two ventilation strategies designed to increase meanthoracic volume. Dynamic hyperinflation (DH) was produced byventilating the lungs at a rate of 50 breaths/min and with a duty cycleof 0.5. Static hyperinflation (SH) was produced throughthe application of extrinsic positive end-expiratory pressure while thelungs were ventilated at a rate of 15 breaths/min and with a duty cycleof 0.15. Regional tidal volume(VT,r), regional functionalresidual volume, and the time delay between regional expansion and the flow signal at the common airway were computed for upto 100 regions/lobe in 5 animals. Ventilation strategy had no effect onthe overall variance of VT,rwithin lobes. Although the VT,rmeasured during SH correlated withVT,r measured during DH, theaverage correlation coefficient was only 0.69. Ventilation rate-relateddifferences in VT,r and regionalfunctional residual capacity varied with the regional time delay inways qualitatively consistent with parallel inhomogeneity of unit timeconstants. However, a large component of frequency-dependent behaviorremains unexplained by established mechanisms. We conclude that DH and SH should not be considered equivalent lung unit recruitmentstrategies.

  相似文献   

7.
Airway function is largely preserved during exercise or isocapnic hyperventilation in humans and guinea pigs despite likely changes in airway milieu during hyperpnea. It is only on cessation of a hyperpneic challenge that airway function deteriorates significantly. We tested the hypothesis that nitric oxide, a known bronchodilator that is produced in the lungs and bronchi, might be responsible for the relative bronchodilation observed during hyperventilation (HV) in guinea pigs. Three groups of anesthetized guinea pigs were given saline and three groups given 50 mg/kg N(G)-monomethyl-L-arginine (L-NMMA), a potent nitric oxide synthase inhibitor. Three isocapnic ventilation groups included normal ventilation [40 breaths/min, 6 ml/kg tidal volume (VT)], increased respiratory rate only (150 breaths/min, 6 ml/kg VT), and increased respiratory rate and increased volume (100 breaths/min, 8 ml/kg VT). L-NMMA reduced expired nitric oxide in all groups. Expired nitric oxide was slightly but significantly increased by HV in the saline groups. However, inhibition of nitric oxide production had no significant effect on rate of rise of respiratory system resistance (Rrs) during HV or on the larger rise in Rrs seen 6 min after HV. We conclude that nitric oxide synthase inhibition has no effect on changes in Rrs, either during or after HV in guinea pigs.  相似文献   

8.
Many chronic human lung diseases have their origin in early childhood, yet most murine models used to study them utilize adult mice. An important component of the asthma phenotype is exaggerated airway responses, frequently modelled by methacholine (MCh) challenge. The present study was undertaken to characterize MCh responses in mice from 2 to 8 wk of age measuring absolute lung volume and volume-corrected respiratory mechanics as outcome variables. Female BALB/c mice aged 2, 3, 4, 6, and 8 wk were studied during cumulative intravenous MCh challenge. Following each MCh dose, absolute lung volume was measured plethysmographically at functional residual volume and during a slow inflation to 20-hPa transrespiratory pressure. Respiratory system impedance was measured continuously during the inflation maneuver and partitioned into airway and constant-phase parenchymal components by model fitting. Volume-corrected (specific) estimates of respiratory mechanics were calculated. Intravenous MCh challenge induced a predominantly airway response with no evidence of airway closure in any age group. No changes in functional residual volume were seen in mice of any age during the MCh challenge. The specific airway resistance MCh dose response curves did not show significant differences between the age groups. The results from the present study do not show systematic differences in MCh responsiveness in mice from 2 to 8 wk of age.  相似文献   

9.
We examined the response of pulmonary rapidly adapting receptors (RAR's) to changes in dynamic lung compliance (Cdyn) in the physiological range. RAR impulse activity was recorded from the cervical vagus nerves in anesthetized open-chest dogs whose lungs were ventilated at constant rate and tidal volume (VT), with a positive end-expiratory pressure (PEEP) of 3-4 cmH2O. After hyperinflation to produce maximal Cdyn, RAR's were silent or fired sparsely and irregularly. Reducing Cdyn in steps by briefly removing PEEP increased firing proportionately, and RAR's began to discharge vigorously in inflation. Activity was restored to control by hyperinflating the lungs. Activity also increased when we increased inflation rate, and hence the rate of change of airway pressure (dP/dt), by reducing inflation time, keeping VT and cycle length constant. RAR's were stimulated more when dP/dt was increased by reducing compliance than when dP/dt was increased by increasing inflation rate. We conclude that RAR's are sensitive to changes in Cdyn and speculate that excitatory input from RAR's may help to maintain VT as the lungs become stiffer.  相似文献   

10.
Mechanism of action of ozone on the human lung   总被引:3,自引:0,他引:3  
Fourteen healthy normal volunteers were randomly exposed to air and 0.5 ppm of ozone (O3) in a controlled exposure chamber for a 2-h period during which 15 min of treadmill exercise sufficient to produce a ventilation of approximately 40 l/min was alternated with 15-min rest periods. Before testing an esophageal balloon was inserted, and lung volumes, flow rates, maximal inspiratory (at residual volume and functional residual capacity) and expiratory (at total lung capacity and functional residual capacity) mouth pressures, and pulmonary mechanics (static and dynamic compliance and airway resistance) were measured before and immediately after the exposure period. After the postexposure measurements had been completed, the subjects inhaled an aerosol of 20% lidocaine until response to citric acid aerosol inhalation was abolished. All of the measurements were immediately repeated. We found that the O3 exposure 1) induced a significant mean decrement of 17.8% in vital capacity (this change was the result of a marked fall in inspiratory capacity without significant increase in residual volume), 2) significantly increased mean airway resistance and specific airway resistance but did not change dynamic or static pulmonary compliance or viscous or elastic work, 3) significantly reduced maximal transpulmonary pressure (by 19%) but produced no changes in inspiratory or expiratory maximal mouth pressures, and 4) significantly increased respiratory rate (in 5 subjects by more than 6 breaths/min) and decreased tidal volume.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

11.
Expiratory flow limitation (EFL) can occur in mechanically ventilated patients with chronic obstructive pulmonary disease and other disorders. It leads to dynamic hyperinflation with ensuing deleterious consequences. Detecting EFL is thus clinically relevant. Easily applicable methods however lack this detection being routinely made in intensive care. Using a simple mathematical model, we propose a new method to detect EFL that does not require any intervention or modification of the ongoing therapeutic. The model consists in a monoalveolar representation of the respiratory system, including a collapsible airway that is submitted to periodic changes in pressure at the airway opening: EFL provokes a sharp expiratory increase in the resistance Rc of the collapsible airway. The model parameters were identified via the Levenberg-Marquardt method by fitting simulated data on the airway pressure and the flow signals recorded in 10 mechanically ventilated patients. A sensitivity study demonstrated that only 8/11 parameters needed to be identified, the remaining three being given reasonable physiological values. Flow-volume curves built at different levels of positive expiratory pressure, PEEP, during "PEEP trials" (stepwise increases in positive end-expiratory pressure to optimize ventilator settings) have shown evidence of EFL in three cases. This was concordant with parameter identification (high Rc during expiration for EFL patients). We conclude from these preliminary results that our model is a potential tool for the non-invasive detection of EFL in mechanically ventilated patients.  相似文献   

12.
Shen, X., S. J. Gunst, and R. S. Tepper. Effect oftidal volume and frequency on airway responsiveness in mechanically ventilated rabbits. J. Appl. Physiol.83(4): 1202-1208, 1997.We evaluated the effects of the rate andvolume of tidal ventilation on airway resistance (Raw) duringintravenous methacholine (MCh) challenge in mechanically ventilatedrabbits. Five rabbits were challenged at tidal volumes of 5, 10, and 20 ml/kg at a frequency of 15 breaths/min and also under static conditions(0 ml/kg tidal volume). Four rabbits were subjected to MCh challenge atfrequencies of 6 and 30 breaths/min with a tidal volume of 10 ml/kg andalso under static conditions. In both groups, the increase in Raw with MCh challenge was significantly greater under static conditions thanduring tidal ventilation at any frequency or volume. Increases in thevolume or frequency of tidal ventilation resulted in significant decreases in Raw in response to MCh. We conclude that tidal breathing suppresses airway responsiveness in rabbits in vivo. The suppression ofnarrowing in response to MCh increases as the magnitude of the volumeor the frequency of the tidal oscillations is increased. Our findingssuggest that the effect of lung volume changes on airway responsivenessin vivo is primarily related to the stretch of airway smooth muscle.

  相似文献   

13.
During breathing under sedation via a two-way valve, airflow (V), volume (delta V), and airway pressure (P) were recorded in eight normal (N) infants, seven with reversible obstructive airway disease (ROAD), and seven with chronic lung disease (CLD). Intermittently, expiratory volume clamping (EVC) was applied, involving selective occlusion of the expiratory valve for three to five breaths. The latter produced cumulative increases in delta V that, due to progressive recruitment of the Hering-Breuer reflex, were accompanied by increasing expiratory plateaus in P (i.e., apneas). The resultant passive inflation delta V-P relationships were closely approximated by the expression: delta V = aP2 + bP + c, wherein a represented the pressure-related changes in chord compliance (Crs), b the Crs at P = 0, and c the difference between the dynamic end-expiratory and relaxation volumes of the respiratory system. Relative to N, the ROAD and CLD infants had significantly reduced weight-specific values of a/kg, their b/kg values were increased, whereas the c/kg measurements did not significantly vary. Moreover, for each subject we determined the net Crs/kg obtaining at P = 20 cmH2O (i.e., Crs20/kg), an estimate of the net deflation compliance; the passive respiratory time constant (tau rs) based on the slope of the expired delta V/V relationship; and the respiratory system conductance (Grs/kg). Relative to N, the mean Crs20/kg was significantly reduced only in the infants with CLD and, due to increases in tau rs, both patient groups depicted significantly diminished values of Grs/kg, suggesting the presence of airways obstruction.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

14.
We examined the effects of positive end-expiratory pressure (PEEP) and tidal volume on the distribution of ventilation and perfusion in a canine model of asymmetric lung injury. Unilateral right lung edema was established in 10 animals by use of a selective infusion of ethchlorvynol. Five animals were tested in the supine position (horizontal asymmetry) and five in the right decubitus position (vertical asymmetry). Raising PEEP from 5 to 12 cmH2O improved oxygenation despite a redistribution of blood flow toward the damage lung and a consistent decrease in total respiratory system compliance. This improvement paralleled a redistribution of tidal ventilation to the injured lung. This was effected primarily by a fall in the compliance of the noninjured lung due to hyperinflation. The effects of higher tidal volume were additive to those of PEEP. We propose that the major effect of PEEP in inhomogeneous lung injury is to restore tidal ventilation to a population of alveoli recruitable only at high airway pressures.  相似文献   

15.
Sun JG  Deng YM  Wu X  Tang HF  Deng JF  Chen JQ  Yang SY  Xie QM 《Life sciences》2006,79(22):2077-2085
Phosphodiesterase 4 (PDE4) isozyme plays important roles in inflammatory and immunomodulatory cells. In this study, piclamilast, a selective PDE4 inhibitor, was used to investigate the role of PDE4 in respiratory function and inflammation in a murine asthma model. Sensitized mice were challenged with aerosolized ovalbumin for 7 days, piclamilast (1, 3 and 10 mg/kg) and dexamethasone (2 mg/kg) were orally administered once daily during the period of challenge. Twenty-four hours after the last challenge, airway hyperresponsiveness to methacholine was determined by whole-body plethysmography, airway inflammation and mucus secretion by histomorphometry, pulmonary cAMP-PDE activity by HPLC, cytokine levels in bronchoalveolar lavage fluid and their mRNA expression in lung by ELISA and RT-PCR, respectively. In control mice, significant induction of cAMP-PDE activity was parallel to the increases of hyperresponsiveness, inflammatory cells, cytokine levels, mRNA expression as well as goblet cell hyperplasia. However, piclamilast dose-dependently and significantly improved airway resistance and dynamic compliance, and the maximal effect was similar to that of dexamethasone. Piclamilast treatment dose-dependently and significantly prevented the increase in inflammatory cell number and goblet cell hyperplasia, as well as production of cytokines, including eotaxin, TNFalpha and IL-4. Piclamilast exerted a weaker inhibitory effect than dexamethasone on eosinophils and neutrophils, had no effect on lymphocyte accumulation. Moreover, piclamilast inhibited up-regulation of cAMP-PDE activity and cytokine mRNA expression; the maximal inhibition of cAMP-PDE was greater than that exerted by dexamethasone, and was similar to dexamethasone on cytokine mRNA expression. This study suggests that inhibition of PDE4 by piclamilast robustly improves the pulmonary function, airway inflammation and goblet cell hyperplasia in murine allergenic asthma.  相似文献   

16.
Deep breaths taken before inhalation of methacholine attenuate the decrease in forced expiratory volume in 1 s and forced vital capacity in healthy but not in asthmatic subjects. We investigated whether this difference also exists by using measurements not preceded by full inflation, i.e., airway conductance, functional residual capacity, as well as flow and residual volume from partial forced expiration. We found that five deep breaths preceding a single dose of methacholine 1) transiently attenuated the decrements in forced expiratory volume in 1 s and forced vital capacity in healthy (n = 8) but not in mild asthmatic (n = 10) subjects and 2) increased the areas under the curve of changes in parameters not preceded by a full inflation over 40 min, during which further deep breaths were prohibited, without significant difference between healthy (n = 6) and mild asthmatic (n = 16) subjects. In conclusion, a series of deep breaths preceding methacholine inhalation significantly enhances bronchoconstrictor response similarly in mild asthmatic and healthy subjects but facilitates bronchodilatation on further full inflation in the latter.  相似文献   

17.
Although positive airway pressure is often used to treat acute pulmonary edema, the effects on epithelial solute flux are not well known. We measured independently the effect of 1) positive pressure and 2) voluntary hyperinflation on the clearance of inhaled technetium-99m-labeled diethylenetriaminepentaacetic acid (99mTc-DTPA) in six nonsmokers and six smokers. Lung volumes were monitored by inductance plethysmography. Each subject was studied in four situations: 1) low end-expiratory volume (LO-), 2) low volume plus 9 cmH2O continuous positive airway pressure (LO+), 3) high end-expiratory volume (HI-), and 4) high volume plus continuous positive airway pressure (HI+). The clearance half time of 99mTc-DTPA for the nonsmokers decreased from 64.8 +/- 7.0 min (mean +/- SE) at LO- to 23.2 +/- 5.3 min at HI- (P less than 0.05). Positive pressure had no synergistic effect. The mean clearance half time for the smokers was faster than nonsmokers at base line but unaffected by similar changes in thoracic volume and pressure. We conclude that, in nonsmokers, positive airway pressure increases 99mTc-DTPA clearance primarily through an increase in lung volume and that smokers are immune to these effects.  相似文献   

18.
We have designed a new endotracheal flowmeter to measure tidal volume, phasic and mean airway pressures, inspiratory time, and end-tidal PCO2 and PO2 in intubated infants. The flowmeter is light (11 g) and adds minimal dead space (1.0 ml) and resistance (2 cmH2O X 100 ml- X s) to the infant's airway. The volume signal (less than or equal to 10 ml) is linear to 7 Hz, and end-tidal gases can be measured at respiratory rates of 90 breaths/min. This flowmeter is particularly valuable for evaluation of rapid mechanical ventilation of very low birth weight infants.  相似文献   

19.
Pressure-volume behavior of the upper airway   总被引:1,自引:0,他引:1  
The study was performed to investigate the relationship between force generation and upper airway expansion during respiratory efforts by upper airway muscles. In 11 anesthetized dogs we isolated the upper airway (nasal, oral, pharyngeal, and laryngeal regions) by transecting the cervical trachea and sealing the nasal and oral openings. During spontaneous respiratory efforts the pressure within the sealed upper airway, used as an index of dilating force, decreased during inspiration. On alternate breaths the upper airway was opened to a pneumotachograph, and an increase in volume occurred, also during inspiration. Progressive hyperoxic hypercapnia produced by rebreathing increased the magnitude of change in pressure and volume. At any level of drive, peak pressure or volume occurred at the same point during inspiration. At any level of drive, volume and pressure changes increased with end-expiratory occlusion of the trachea. The force-volume relationship determined from measurements during rebreathing was compared with pressure-volume curves performed by passive inflation of the airway while the animal was apneic. The relationship during apnea was 1.06 +/- 0.55 (SD) ml/cmH2O, while the force-volume relationship from rebreathing trials was -1.09 +/- 0.45 ml/cmH2O. We conclude that there is a correspondence between force production and volume expansion in the upper airway during active respiratory efforts.  相似文献   

20.
Because the presence of bronchial smooth muscle reactivity in infants remains controversial, airway reactivity was assessed in 10 normal, asymptomatic male infants less than 15 mo of age by measuring the changes that occurred in the maximal expiratory flows at functional residual capacity (VmaxFRC) during a methacholine bronchial challenge test. Sleeping infants inhaled doubling concentrations of methacholine by 2 min of tidal breathing, starting with a concentration of 0.075 mg/ml, and the bronchial challenge was stopped when VmaxFRC decreased by at least 40%. The threshold concentration of methacholine required to produce a decrease in VmaxFRC by 2 SD's of the control value was 0.43 mg/ml (0.11-0.90). By a methacholine concentration of 1.2 mg/ml, all infants decreased VmaxFRC by at least 40% (range 40-75%), and the mean dose required to produce a 40% decrease was 0.72 mg/ml. The airway reactivity was not related to base-line flows. During the methacholine challenge, no infant developed wheezing, but the percent oxygen saturation for the group decreased significantly (P less than 0.05) from 94 to 92%. Following the methacholine, the infants inhaled the bronchodilator metaproterenol, and 10 min later, VmaxFRC returned to base line. This study demonstrates that infants exhibit airway reactivity as evidenced by bronchoconstriction with methacholine and the subsequent bronchodilation with metaproterenol.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号