首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
C. P. Warren 《CMAJ》1977,116(4):391-394
Lung diseases in farmers attributable to their occupation include (a) farmer''s lung, caused by exposure to mouldy hay, (b) the asthma caused by exposure to grain dust and (c) silo-filler''s disease. Their prevalence in Canada is unknown. Farmer''s lung results from inhalation of mould spores in hay; the mechanism is immunologic. The exact cause and mechanism of grain dust asthma are unknown but may be immunologic. Silo-filler''s disease is caused by the toxic effects of inhaled nitrogen dioxide.  相似文献   

2.
In a survey of the farming population of Orkney, Ayrshire, and East Lothian the prevalence of farmer''s lung was estimated at 86 per 1,000 in both Orkney and Ayrshire and 23 per 1,000 in East Lothian. If cases with a negative farmer''s lung hay (F.L.H.) precipitin test are excluded these figures are reduced to 43, 36, and nil respectively, but those for Orkney and Ayrshire are still about 20 times higher than any figure previously reported for the prevalence of farmer''s lung in Britain.Regional variations in prevalence are probably related both to climatic conditions and to differences in agricultural methods, the latter often being dictated by economic circumstances. Nevertheless the prevalence of farmer''s lung could be reduced considerably by the energetic application of preventive measures, backed by financial incentives. The most important of these are efficient drying of hay and cereals before storage, more extensive use of silage, better ventilation of farm buildings, and the introduction of mechanical feeding systems. Individual farmworkers could be taught how to recognize the early symptoms of the disease and encouraged to wear respirators when handling mouldy fodder.  相似文献   

3.
C. P. Warren  J. Manfreda 《CMAJ》1980,122(11):1259-1264
Of a random sample of farmers in two crop districts of Manitoba mailed a respiratory questionnaire in 1976, 833 (82% of those currently farming in the area) replied. More than half were grain farmers and nearly half had never smoked cigarettes. The prevalence of chronic cough and phlegm production, wheezing and exertional dyspnea was positively related to the amount of smoking but was also higher than expected in nonsmokers. Acute dyspnea, sometimes of delayed onset and accompanied by fever, was most commonly related to handling old grain and was reported by 44% of the farmers. Current smokers were more susceptible than nonsmokers to this type of dyspnea. Farmers with history of acute dyspnea while handling grain were more likely to wear masks, but the overall rate of mask wearing, even among those at highest risk, was low.  相似文献   

4.

Background

Reduced lung function predicts increased mortality, but its prevalence may vary depending on definition considered, use of bronchodilation and applied reference values. We aimed to assess lung function abnormalities in Lausanne, Switzerland, and their association with clinical history.

Methods

In a general population sample, spirometry was performed and bronchodilation applied if the ratio forced expiratory volume in 1?s (FEV1) / forced vital capacity (FVC) or the FVC was below the lower limit of normal (LLN) according to Global Lung Function Initiative 2012 references. Results for FEV1/FVC according to the LLN were compared to the 0.7 fixed ratio. Respiratory risk factors, symptoms and self-reported respiratory diagnoses were recorded through a questionnaire.

Results

Out of the 3342 included subjects, 3.8% had chronic obstruction and 2.5% reversible obstruction when using the LLN; possible lung restriction alone was present in 1.8%, and associated with chronic obstruction in 0.4%. Ever smokers had a higher prevalence of abnormal spirometry, chronic obstruction and reversible obstruction; there was no difference with regard to possible restriction. Overall, chronic airway obstruction was found in 8.9% of current smokers, 4.6% of former smokers and 1.5% of never smokers. Only one third of participants with chronic obstruction were aware of a respiratory disease.

Conclusion

Prevalence of abnormal lung function in the population of Lausanne is low. This may be due to a low rate of ever-smokers, the application of a full bronchodilation dose, but also to inherent characteristics of this population.
  相似文献   

5.
OBJECTIVE--To determine whether birth weight and gestational age are associated with respiratory illness and lung function in children aged 5-11 years. DESIGN--Cross sectional analysis of parent reported birth weight, gestational age, and respiratory symptoms; parental smoking and social conditions; forced vital capacity (FVC), forced expiratory volume in one second (FEV1), forced expiratory rates between 25% and 75% and 75% and 85% (FEF25-75 and FEF75-85), and height. SETTING--Primary schools in England and Scotland in 1990. SUBJECTS--5573 children aged 5-11 (63.3% of eligible children) had respiratory symptoms analysed and 2036 children (67.1% of eligible children) had lung function measured. MAIN OUTCOME MEASURES--Symptoms of asthma, bronchitis, occasional and frequent wheeze, cough first thing in the morning, and cough at any other time and lung function. RESULTS--Birth weight adjusted for gestational age was significantly associated with all lung function measurements, except FEF25-75. The association remained for FVC (b = 0.475, 95% confidence interval 0.181 to 0.769) and FEV1 (b = 0.502, 0.204 to 0.800) after adjustment for gestational age, parental smoking, and social factors. FEF75-85 was the only lung function related to gestational age. Respiratory symptoms, especially wheeze most days (adjusted odds ratio 0.9, 0.84 to 0.97) were significantly associated with prematurity. Every extra week of gestation reduced the risk of severe wheeze by about 10%. CONCLUSIONS--Lung function is affected mainly by intrauterine environment while respiratory illness, especially wheezing, in childhood is related to prematurity.  相似文献   

6.
Art students are exposed to many noxious agents during their training. We studied respiratory findings in a cohort of the 117 art students in order to investigate the potential effects of these toxic agents in the art student's environment. A group of 88 medical students matched for age, sex and smoking, not exposed to known environmental pollutants were studied as controls for respiratory symptoms. Respiratory symptoms acute and chronic were evaluated by modifying the British Medical Research Council questionnaire. Lung function studies were performed with a spirometer (Jaeger, Germany) measuring maximum expiratory flow-volume (MEFV) curves. Significantly higher prevalences of most of the chronic respiratory symptoms were recorded in art compared to medical students (p < 0.05). Art students who were smokers had significantly higher prevalences of many of the chronic respiratory symptoms than nonsmoking art students. High prevalences of acute symptoms related to the study environment were recorded for art students. Odds ratios in male art students were significant for chronic cough, chronic phlegm and chronic bronchitis for the risk factors of exposure and smoking. Significantly decreased lung function was recorded for FVC, FEF50 and FEF25 in male and FVC, and FEF25 in female art students. Smokers and nonsmokers had similar reductions of lung function. Our data indicate that art students may be at risk of developing chronic respiratory symptoms and lung function changes as a result of their exposure and their smoking habits.  相似文献   

7.
OBJECTIVE: To examine the role of exposure to the 1984 Bhopal gas leak in the development of persistent obstructive airways disease. DESIGN: Cross sectional survey. SETTING: Bhopal, India. SUBJECTS: Random sample of 454 adults stratified by distance of residence from the Union Carbide plant. MAIN OUTCOME MEASURES: Self reported respiratory symptoms; indices of lung function measured by simple spirometry and adjusted for age, sex, and height according to Indian derived regression equations. RESULTS: Respiratory symptoms were significantly more common and lung function (percentage predicted forced expiratory volume in one second (FEV1), forced vital capacity (FVC), forced expiratory flow between 25% and 75% of vital capacity (FEF25-75), and FEV1/FVC ratio) was reduced among those reporting exposure to the gas leak. The frequency of symptoms fell as exposure decreased (as estimated by distance lived from the plant), and lung function measurements displayed similar trends. These findings were not wholly accounted for by confounding by smoking or literacy, a measure of socioeconomic status. Lung function measurements were consistently lower in those reporting symptoms. CONCLUSION: Our results suggest that persistent small airways obstruction among survivors of the 1984 disaster may be attributed to gas exposure.  相似文献   

8.
Two patients with allergic alveolitis due to mouldy hay antigens (farmer''s lung) were shown to have malabsorption due to coeliac disease. As similar associations have been found with other alveolar diseases, this association is probably not fortuitous and further population screening should be done.  相似文献   

9.
a survey of respiratory disease among male physicians of London, Ontario, resulted in a 96.3% response.The age-standardized rates of chronic bronchitis were not very different from others reported in the recent medical literature, taking into account smoking habits, but the overall prevalence of bronchial asthma was high (7.4%), with a low prevalence in the category “obstructive lung disease”. The possibility of overlap or interchange in these diagnoses is raised, although the diagnosis of bronchial asthma in this particular group is believed to be well established in every case.A history of seasonal hay fever was given by 19.4%.One of 88 (1%) non-smokers had bronchitis, whereas six of them (7%) had asthma.Rhonchi heard in the chest, on a single examination, appeared to be most closely related to current smoking habits, ventilatory function tests and also to a clinical diagnosis of chronic bronchitis or obstructive lung disease, but not to bronchial asthma.  相似文献   

10.
Summary We evaluated the effects of some indoor environmental factors in a non smoking subsample (n=381, age 8–19 years) of the general population living in the Po River Delta. Each subject completed an interviewer-administered standardized questionnaire on respiratory symptoms and risk factors. Acceptable maneuvers of forced vital capacity and slope of alveolar plateau of nitrogen were obtained in 96% and 59% of the subjects, respectively. In the houses there were more frequently natural gas for cooking (86%) than bottled gas (14%) and central heating (82%) than stove (18%). As regards passive smoking exposure, 18% of subjects had both parents smoking, 50% had one parent smoking. Significantly higher prevalence rates of wheeze, dyspnea, diagnosis of asthma were found in subjects of both sexes using bottled gas for cooking in comparison to those using natural gas, when also exposed to passive smoking. An insignificant trend towards higher symptom rates was shown by those using stove, instead of central heating. Lung function was affected only in females: those with both parents smoking had reduced forced expirograms, those with bottled gas for cooking or stove for heating had a decreased peak expiratory flow. Interactions of stove and passive smoking on peak expiratory flow and on slope of alveolar plateau were statistically significant. These findings confirm the mild adverse respiratory effects of certain home environment factors shown by other epidemiologic surveys in North Europe and in the USA. They have been a basis for the implementation, under the auspices of National Research Council and Electric Energy Authority, of future specific studies in which continuous monitoring of indoor pollutants and repeated recording of symptoms and lung function in North and Central Italy will be performed.  相似文献   

11.
OBJECTIVE--To examine the relation between damp and mould growth and symptomatic ill health. DESIGN--Cross-sectional study of random sample of households containing children; separate and independent assessments of housing conditions (by surveyor) and health (structured interview by trained researcher). SETTING--Subjects'' homes (in selected areas of public housing in Glasgow, Edinburgh, and London). SUBJECTS--Adult respondents (94% women) and 1169 children living in 597 households. END POINTS--Specific health symptoms and general evaluation of health among respondents and children over two weeks before interview; and score on general health questionnaire (only respondents). MEASUREMENTS AND MAIN RESULTS--Damp was found in 184 (30.8%) dwellings and actual mould growth in 274 (45.9%). Adult respondents living in damp and mouldy dwellings were likely to report more symptoms overall, including nausea and vomiting, blocked nose, breathlessness, backache, fainting, and bad nerves, than respondents in dry dwellings. Children living in damp and mouldy dwellings had a greater prevalence of respiratory symptoms (wheeze, sore throat, runny nose) and headaches and fever compared with those living in dry dwellings. The mean number of symptoms was higher in damp and mouldy houses and positively associated with increasing severity of dampness and mould (dose response relation). All these differences persisted after controlling for possible confounding factors such as household income, cigarette smoking, unemployment, and overcrowding. Other possible sources of bias that might invalidate the assumption of a causal link between housing conditions and ill health--namely, investigator bias, respondent bias, and selection bias--were also considered and ruled out. CONCLUSION--Damp and mouldy living conditions have an adverse effect on symptomatic health, particularly among children.  相似文献   

12.
The ventilatory capacity, including flow-volume curves of 313 men, all 50 years old, was examined in 1963 and 1967. The group as a whole, which included persons with chronic bronchitis, with “other respiratory symptoms,” and without respiratory symptoms, showed the same absolute decrease in ventilatory capacity.Vital capacity, forced expiratory volume, and maximum expiratory flow all dropped more for the smokers than for either the non-smokers or the ex-smokers. In those who had stopped smoking for four years or less, however, ventilatory capacity did not decline significantly less than in those who continued to smoke.  相似文献   

13.
Lung mechanics and airway responsiveness to methacholine (MCh) were studied in seven volunteers before and after a 20-min intravenous infusion of saline. Data were compared with those of a time point-matched control study. The following parameters were measured: 1-s forced expiratory volume, forced vital capacity, flows at 40% of control forced vital capacity on maximal (Vm(40)) and partial (Vp(40)) forced expiratory maneuvers, lung volumes, lung elastic recoil, lung resistance (Rl), dynamic elastance (Edyn), and within-breath resistance of respiratory system (Rrs). Rl and Edyn were measured during tidal breathing before and for 2 min after a deep inhalation and also at different lung volumes above and below functional residual capacity. Rrs was measured at functional residual capacity and at total lung capacity. Before MCh, saline infusion caused significant decrements of forced expiratory volume in 1 s, Vm(40), and Vp(40), but insignificantly affected lung volumes, elastic recoil, Rl, Edyn, and Rrs at any lung volume. Furthermore, saline infusion was associated with an increased response to MCh, which was not associated with significant changes in the ratio of Vm(40) to Vp(40). In conclusion, mild airflow obstruction and enhanced airway responsiveness were observed after saline, but this was not apparently due to altered elastic properties of the lung or inability of the airways to dilate with deep inhalation. It is speculated that it was likely the result of airway wall edema encroaching on the bronchial lumen.  相似文献   

14.
Data from the Tucson epidemiological study of airways obstructive disease on smoking of non-tobacco cigarettes such as marijuana were analysed to determine the effect of such smoking on respiratory symptoms and pulmonary function. Among adults aged under 40, 14% had smoked non-tobacco cigarettes at some time and 9% were current users. The prevalence of respiratory symptoms was increased in smokers of non-tobacco cigarettes. After tobacco smoking had been controlled for men who smoked non-tobacco cigarettes showed significant decreases in expiratory flow rates at low lung volumes and in the ratio of the forced expiratory volume in one second to the vital capacity. This effect on pulmonary function in male non-tobacco cigarette smokers was greater than the effect of tobacco cigarette smoking. These data suggest that non-tobacco cigarette smoking may be an important risk factor in young adults with respiratory symptoms or evidence of airways obstruction.  相似文献   

15.
OBJECTIVE--To investigate the prevalence and diagnosis of chronic respiratory disease in adults. DESIGN--Screening questionnaire was sent to all patients aged 40-70 on the register of a group general practice; those responding positively were sent a detailed questionnaire and invited for assessment of respiratory function by forced expiratory volume in one second, forced vital capacity, peak flow rate, and reversibility studies with a beta adrenergic inhaler. SETTING--Group general practice in south west London. RESULTS--Of 2387 patients aged 40-70, 1444 completed a screening questionnaire. Of the 509 patients who reported cough, phlegm, wheeze, or shortness of breath, 324 responded to a detailed questionnaire, 256 of whom had simple respiratory function assessed. Chronic bronchitis affected 106 (17%) men and 58 (7%) women, and wheeze occurring at least once a week affected 60 (9%) men and 20 (3%) women. Only a half to a third of patients had received a diagnostic label of chronic bronchitis or asthma for their symptoms. There was considerable clinical and physiological similarity (including reversibility of the airways) between patients labelled as having asthma and having chronic bronchitis. A label of asthma was used more often for patients of social classes I and II. CONCLUSIONS--Comparison with prevalence surveys carried out in the 1950s showed that respiratory symptoms are as common now as then, but the risk of disabling chronic bronchitis has fallen, more among men than women, probably because of their reduced smoking. Changes in diagnostic fashion, together with increased detection, may have contributed to the upward trend in reported morbidity from asthma over the past 30 years.  相似文献   

16.

Introduction

Pulmonary function abnormalities have been described in multiple sclerosis including reductions in forced vital capacity (FVC) and cough but the time course of this impairment is unknown. Peak cough flow (PCF) is an important parameter for patients with respiratory muscle weakness and a reduced PCF has a direct impact on airway clearance and may therefore increase the risk of respiratory tract infections. Lung volume recruitment is a technique that improves PCF by inflating the lungs to their maximal insufflation capacity.

Objectives

Our goals were to describe the rate of decline of pulmonary function and PCF in patients with multiple sclerosis and describe the use of lung volume recruitment in this population.

Methods

We reviewed all patients with multiple sclerosis referred to a respiratory neuromuscular rehabilitation clinic from February 1999 until December 2010. Lung volume recruitment was attempted in patients with FVC <80% predicted. Regular twice daily lung volume recruitment was prescribed if it resulted in a significant improvement in the laboratory.

Results

There were 79 patients included, 35 of whom were seen more than once. A baseline FVC <80% predicted was present in 82% of patients and 80% of patients had a PCF insufficient for airway clearance. There was a significant decline in FVC (122.6 mL/y, 95% CI 54.9–190.3) and PCF (192 mL/s/y, 95% 72–311) over a median follow-up time of 13.4 months. Lung volume recruitment was associated with a slower decline in FVC (p<0.0001) and PCF (p = 0.042).

Conclusion

Pulmonary function and cough decline significantly over time in selected patients with multiple sclerosis and lung volume recruitment is associated with a slower rate of decline in lung function and peak cough flow. Given design limitations, additional studies are needed to assess the role of lung volume recruitment in patients with multiple sclerosis.  相似文献   

17.
The aim of this study, was to determine the prevalence of some respiratory symptoms and possible diseases among taxi drivers and manual workers. This prospective study was performed on 165 Pakistani male drivers, (mean age: 34.5±7.8 years) and 165 Pakistani male manual workers not exposed to dust or fumes, without occupational exposure to driving employed in the Water and Electricity Department and recruited as controls (mean age: 34.6±7.6 years and mean height and weight 169.8±6.0 cm and 71.9±10.9 kg). The data on chronic respiratory symptoms showed that taxi drivers had higher prevalence of symptoms than manual workers, being significantly greater for asthma (RR=1.72; 95% CI=1.00–2.88,P=0.037); allergic rhinitis (RR=2.41; 95% CI=1.46–3.94,P=0.0006); dyspnea (RR=2.13; 95% CI=1.22–3.71,P=0.009); and nasal catarrh (RR=2.19; 95% CI=1.22–3.91,P=0.0106). Thirty percent of taxi drivers and 27% of manual workers were smokers, there was no significant differences in the prevalence of chronic respiratory symptoms between smokers and non-smokers. Lung function parameters in the taxi drivers were significantly lower than in manual workers group (P<0.0001) except PEF parameter. When comparing the measured mean values of lung function parameters in the drivers among smokers and nonsmokers, there was no significant differences between smokers and nonsmokers. Also, a comparison of ventilatory capacity of paired predicted values with measured normal values showed statistically significant differences between predicted and measured values for taxi drivers and manual workers for FVC, FEV1, FEF25–75 and PEF parameters except for FEV1/FVC test in manual workers. In conclusion, the results of the present study provide evidence regarding effects of such as carbon monoxide, nitrogen dioxide, sulfur dioxide and gases exposures on taxi drivers and long-term driving, which may be associated with the development of chronic respiratory symptoms and lung function impairment.  相似文献   

18.
Chest radiographs and spirometric tests were performed on 81 patients who had silicosis from two granite quarries in 1975, 73 of whom were followed up for two to 10 (mean 7.2) years. Each patient''s initial and most recent chest radiographs were assessed independently by three experienced readers, and the yearly declines in forced expiratory volume in one second and forced vital capacity were estimated from two to four (mean 3.45) serial spirometric readings. Estimates of individual dust exposure were based on extensive historical data on hygiene. All but 11 patients were no longer exposed to dust by the start of follow up, but 24 (45%) of 53 patients who had simple silicosis and 11 (55%) of 20 who had the complicated disease showed radiological evidence of disease progression. In patients who had simple silicosis and showed no radiological progression the yearly declines in forced expiratory volume in one second and forced vital capacity were modest (64 ml/year and 59 ml/year, respectively), whereas significantly greater declines in lung function were seen in those who showed radiological evidence of progression (97 ml/year and 95 ml/year, respectively). In addition to radiological progression the previous average dust concentration to which patients had been exposed also influenced declines in both forced expiratory volume in one second and forced vital capacity after allowing for the effects of age, smoking, duration of exposure, history of tuberculosis, initial state of disease, and baseline lung function. The probability of radiological progression was most strongly influenced by the average dust concentration previously exposed to. The progression of simple silicosis is thus accompanied by appreciable declines in lung function and is strongly affected by previous levels of exposure to dust.  相似文献   

19.
The mechanical properties of the lungs were measured in 10 men before and after a simulated air dive to 285 ft of seawater (87 m). The objective was to determine whether a dive likely to produce pulmonary bubble emboli would alter lung mechanics. Lung function was measured predive and at 1, 2, 3, 6, 7, and 23 h postdive. Measurements of lung function were also made at identical times on a control day when no dive was made. Each set of measurements included precordial Doppler signals, pulmonary resistance, quasistatic lung compliance, forced vital capacity (FVC), forced expired volume after 1.0 s (FEV 1.0), the ratio of FEV 1.0 to FVC (FEV 1.0/FVC%), and maximal airflow after 50 and 75% of the vital capacity had been expired (Vmax50 and Vmax75, respectively). Base-line measurements of pulmonary resistance and quasistatic compliance were normal in all subjects. FVC and FEV 1.0 were greater than predicted for most subjects and were increased proportionately so that the FEV 1.0/FVC% was normal. Following the dive, bubble signals were heard in four subjects, and two subjects had mild symptoms of decompression sickness. No subject demonstrated any alteration in lung function that could be attributed to the dive. We concluded that stressful decompressions capable of producing "silent" pulmonary bubble emboli do not alter lung mechanics.  相似文献   

20.

Background

Specific occupations are associated with adverse respiratory health. Inhalation exposures encountered in these jobs may place workers at risk of new-onset respiratory disease.

Methods

We analyzed data from 8,967 participants from the Atherosclerosis Risk in Communities (ARIC) study, a longitudinal cohort study. Participants included in this analysis were free of chronic cough and phlegm, wheezing, asthma, chronic bronchitis, emphysema, and other chronic lung conditions at the baseline examination, when they were aged 45-64 years. Using data collected in the baseline and first follow-up examination, we evaluated associations between occupation and the three-year incidence of cough, phlegm, wheezing, and airway obstruction and changes in forced expiratory volume in one second (FEV1) and forced vital capacity (FVC) measured by spirometry. All associations were adjusted for age, cigarettes per day, race, smoking status, and study center.

Results

During the approximately three-year follow-up, the percentage of participants developing chronic cough was 3%; chronic phlegm, 3%; wheezing, 3%; and airway obstruction, defined as FEV1 < lower limit of normal (LLN) and FEV1/FVC < LLN, 2%. The average annual declines in FEV1 and FVC were 56 mL and 66 mL, respectively, among men and 40 mL and 52 mL, respectively, among women. Relative to a referent category of managerial and administrative support occupations, elevated risks of new-onset chronic cough and chronic phlegm were observed for mechanics and repairers (chronic cough: RR: 1.81, 95% CI: 1.02, 3.21; chronic phlegm: RR: 2.10, 95% CI: 1.23, 3.57) and cleaning and building service workers (chronic cough: RR: 1.85, 95% CI: 1.01, 3.37; chronic phlegm: RR: 2.28, 95% CI: 1.27, 4.08). Despite the elevated risk of new-onset symptoms, employment in cleaning and building services was associated with attenuated lung function decline, particularly among men, who averaged annual declines in FEV1 and FVC of 14 mL and 23 mL, respectively, less than the declines observed in the referent population.

Conclusions

Employment in mechanic and repair jobs and cleaning and building service occupations are associated with increased incidence of respiratory symptoms. Specific occupations affect the respiratory health of adults without pre-existing respiratory health symptoms and conditions, though long-term health consequences of inhalation exposures in these jobs remain largely unexplored.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号