首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive and specific method for determination of viaminate in human plasma by using high-performance liquid chromatography coupled with electrospray tandem mass spectrometry (LC-MS/MS) was developed in this study. The plasma samples were simply deproteinated, extracted, evaporated, and then reconstituted in 200 microl of methanol prior to analysis. Chromatographic separation was carried out on a Shimadzu VP-ODS column (250 mm x 2.0 mm, 5 microm) with a mobile phase of methanol-water (95:5, v/v) at a flow rate of 0.2 ml/min. Quantification was performed in the negative-ion electrospray ionization mode by selected ion monitoring of the product ions at m/z 164 for viaminate and m/z 109 for testosterone propionate which was used as the internal standard. The corresponding parent ions were m/z 446 and m/z 345. A linear calibration curve was observed within the concentration range of 0.10-200 ng/ml. The lowest limit of quantitation (LLOQ) was 0.1 ng/ml. The extraction-efficiency at three concentrations was 100.7, 93.6, and 99.7%. Practical utility of this new LC-MS/MS method was confirmed in pilot pharmacokinetic studies in humans following oral administration.  相似文献   

2.
A liquid chromatographic-mass spectrometric (LC-MS) method with rapid automated sample preparation was developed and validated for determination of glybenclamide in human serum. Glybenclamide and its deuterated labelled internal standard were extracted from human serum samples by automated solid-phase extraction. The extract was injected into the LC-MS system for analysis. Glybenclamide and its internal standard were measured in multiple ion monitoring mode. The method was validated over a range of 10-1000 ng/ml with good accuracy and precision and was applicable for pharmacokinetic studies.  相似文献   

3.
Wang H  Ma C  Zhou J  Liu XQ 《Chirality》2009,21(5):531-538
A specific and relatively sensitive high-performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-ESI-MS) was developed for the quantitative analysis of tiopronin enantiomers in rat plasma. The method is based on the derivatization of (+)-tiopronin and (-)-tiopronin with 2,3,4,6-tetra-O-acetyl-beta-glucopyranosyl isothiocyanate (GITC) in acetonitrile. The separation of resulting diastereomic derivatives was performed on C18 column (150 mm x 2.0 mm ID, packed with 5.0 mum C(18) silica RP particle), using a mobile phase of methanol/water (containing 5.3 mM formic acid) with gradient elution. LC-MS was performed in the selected ion monitoring and positive ion mode using target ions at m/z: 575 for the diastereomic derivatives of tiopronin and m/z: 603 for the derivative of N-isobutyryl-D-cysteine (internal standard). The method was validated in terms of specificity, linearity, sensitivity, precision, accuracy, matrix effect, and stability. The calibration curves were linear over the concentration range of 0.025-5 microg/ml for both enantiomers of tiopronin. For both enantiomers of tiopronin, the interbatch and intrabatch variability values were less than 15%, and the accuracy was within +/-17% in terms of relative error. The method was successfully applied to a pharmacokinetic study of rac-tiopronin in rat.  相似文献   

4.
A rapid, sensitive and selective LC-MS/MS method was developed and validated for the quantification of aniracetam in human plasma using estazolam as internal standard (IS). Following liquid-liquid extraction, the analytes were separated using a mobile phase of methanol-water (60:40, v/v) on a reverse phase C18 column and analyzed by a triple-quadrupole mass spectrometer in the selected reaction monitoring (SRM) mode using the respective [M+H]+ ions, m/z 220-->135 for aniracetam and m/z 295-->205 for the IS. The assay exhibited a linear dynamic range of 0.2-100 ng/mL for aniracetam in human plasma. The lower limit of quantification (LLOQ) was 0.2 ng/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The validated LC-MS/MS method has been successfully applied to study the pharmacokinetics of aniracetam in healthy male Chinese volunteers.  相似文献   

5.
A rapid and sensitive LC-MS/MS method for the quantification of ondansetron was developed and validated. The plasma samples were treated by a semi-automated liquid-liquid extraction (LLE) in 1.2 mL 96-well format micro-tubes. Ondansetron and the internal standard (IS) granisetron were analyzed by combined reversed phase LC-MS/MS, with positive ion electrospray ionization, using multiple reactions monitoring (MRM). The statistical evaluation for this method reveals excellent linearity, accuracy and precision values for the range of concentrations 0.25-40.0 ng/mL. The proposed method enabled the reliable determination of ondansetron in bioequivalence studies after per os administration of a 4 or 8 mg tablet.  相似文献   

6.
A sensitive assay for determination of rifalazil (also known as ABI-1648 and KRM-1648) in human plasma is described. The analytical method utilizes liquid-liquid extraction of plasma with methyl tert-butyl ether, followed by reversed-phase liquid chromatography with a C18 column and a mobile phase gradient utilizing 0.1% formic acid in water and acetonitrile, respectively. Electrospray mass spectrometry in the positive ion mode with selected reaction monitoring of rifalazil and an isotope labeled internal standard, 13C4-rifalazil (ABI-9901) was used for selective and sensitive detection. The calibration range was 0.050-50 ng/mL plasma using 200 microL plasma sample volume. The absolute extraction recovery of rifalazil from K2-EDTA plasma, evaluated at three concentration levels, was 88.6-97.3%, and the recovery for the internal standard was 96.8%. A study of plasma matrix effects showed a peak area response at 90-99% compared to neat solutions for both rifalazil and the internal standard. Stability evaluation of rifalazil in plasma, whole blood and methanol showed that the analyte stability was adequate when stored under study conditions. The precision, as evaluated in three validation batches, was consistent for fortified plasma quality control (QC) samples at four concentration levels, with < or =6% R.S.D. except for at the lowest quality control level where it was 10.7% R.S.D. The accuracy for QC samples (difference between found and nominal concentration) ranged from -2.3% to 5.1%. Similar precision and accuracy values were obtained over 6 months of routine application of this method. It was concluded that the performance improved markedly during routine operation by replacing a closely related structural analog internal standard with the stable isotope internal standard.  相似文献   

7.
A sensitive HPLC-tandem mass spectrometry method was developed for determination of buspirone levels in human plasma. After solid phase extraction and reversed phase HPLC separation, detection of buspirone and the internal standard (prazosin) was performed using eletrospray ionization and selected reaction monitoring in the positive ion mode. Linear calibration curves were established over a concentration range of 0.025-2.5 ng/ml when 0.5 ml aliquots of plasma were used. Satisfactory results of within-day precision (RSD of 1.9-7.7%) and accuracy (% difference of 0.5-6.6%) and between-day precision (RSD of 3.7-11.1%) and accuracy (% difference of 2.2-6.8%) were obtained. The assay has been successfully applied to the analysis of buspirone levels in more than 500 human plasma samples collected from a drug interaction study.  相似文献   

8.
A highly sensitive and specific LC-MS method was developed and validated for the quantification of digoxin in human plasma and urine using d5-dihydrodigoxin as internal standard (IS). The assay procedure involved extraction of digoxin and IS from human plasma with chloroform-isopropanol (95:5, v/v). Chromatogrphic separation was achieved on a Spherisorb ODS2 column using a gradient mobile phase with 5 mmol/L ammonium acetate in water with 1% acetic acid and acetonitrile. The mass spectrometer was operated in the selected ion monitoring mode using the respective [M+K](+) ions, m/z 819.4 for digoxin and m/z 826.4 for IS. The method was proved to be accurate and precise at linearity range of 0.12-19.60 ng/mL in plasma with a correlation coefficient (r(2)) of >or=0.9968 and 1.2-196.0 ng/mL in urine. The limit of quantification achieved with this method was 0.12 ng/mL in plasma and 1.2 ng/mL in urine. The intra- and inter-assay precision and accuracy values were found to be within the assay variability limits as per the FDA guidelines. The developed assay method was successfully applied to a pharmacokinetic study in human volunteers following intravenous administration of digoxin.  相似文献   

9.
Glycyrrhizin (GLY) which has been widely used in traditional Chinese medicinal preparation possesses various pharmacological effects. In order to investigate the pharmacokinetic behavior of GLY in human after oral administration of GLY or licorice root, a liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed and validated for the simultaneous determination of GLY and its major metabolite glycyrrhetic acid (GA) in human plasma. The method involved a solid phase extraction of GLY, GA, and alpha-hederin, the internal standard (IS), from plasma with Waters Oasis MCX solid phase extraction (SPE) cartridges (30 mg) and a detection using a Micromass Quattro LC liquid chromatography/tandem mass spectrometry system with electrospray ionization source in positive ion mode. Separation of the analytes was achieved within 5min on a SepaxHP CN analytical column with a mobile phase of acetonitrile:water (50:50, v:v) containing 0.1% formic acid and 5mM ammonium acetate. Multiple reaction monitoring (MRM) was utilized for the detection monitoring 823--> 453 for GLY, 471--> 177 for GA and 752--> 456 for IS. The LC-MS/MS method was validated for specificity, sensitivity, accuracy, precision, and calibration function. The assay had a calibration range from 10 to 10,000 ng/mL and a lower limit of quantification of 10 ng/mL for both GLY and GA when 0.2 mL plasma was used for extraction. The percent coefficient of variation for accuracy and precision (inter-run and intra-run) for this method was less than 11.0% with a %Nominal ranging from 87.6 to 106.4% for GLY and 93.7 to 107.8% for GA. Stability of the analytes over sample processing (freeze/thaw, bench-top and long-term storage) and in the extracted samples was also tested and established.  相似文献   

10.
A simple, reliable and sensitive liquid chromatography-tandem mass spectrometry method (LC-MS/MS) was developed and validated for quantification of N-acetylglucosamine in human plasma. Plasma samples were pretreated with acetonitrile for protein precipitation. The chromatographic separation was performed on Hypersil Silica column (150mmx2mm, 5microm). The deprotonated analyte ion was detected in negative ionization mode by multiple reaction monitoring mode. The mass transition pairs of m/z 220.3-->118.9 and m/z 226.4-->123.2 were used to detect N-acetylglucosamine and internal standard 13C6-N-acetylglucosamine, respectively. The assay exhibited a linear range from 20 to 1280ng/ml for N-acetylglucosamine in human plasma. Acceptable precision and accuracy were obtained for concentrations of the calibration standard and quality control. The validated method was successfully applied to analyze human plasma samples in a pharmacokinetic study.  相似文献   

11.
A direct liquid chromatographic-tandem mass spectrometric (LC-MS/MS) method for measurement of urinary Delta(9)-tetrahydrocannabinol carboxylic acid (THCA) was developed. The method involved dilution of the urine sample with water containing (2)H(9)-deuterated analogue as internal standard, hydrolysis with ammonia, reversed phase chromatography using a Waters ultra-performance liquid chromatography (UPLC) equipment with gradient elution, negative electrospray ionization, and monitoring of two product ions in selected reaction monitoring mode. The measuring range was 2-1000 ng/mL for THCA, and the intra- and inter-assay imprecision, expressed as the coefficient of variation, was below 5%. Influence from urine matrix on ionization efficiency was noted in infusion experiments, but was compensated for by the internal standard. Comparison with established gas chromatography-mass spectrometry and liquid chromatography-mass spectrometry methods in authentic patient samples demonstrated accuracy in both qualitative and quantitative results. A small difference in mean ratios (~15%) may be explained by the use of different hydrolysis procedures between methods. In conclusion, the high efficiency LC-MS/MS method was capable of accurately identify and quantify THCA in urine with a capacity of 14 samples per hour.  相似文献   

12.
A quantitative liquid chromatography-tandem mass spectrometric (LC-MS/MS) method has been developed for the determination of malachite green (MG) and its metabolite leucomalachite green (LMG) in fish. Residues were extracted with an acetonitrile-acetate buffer and purified using the automated solid-phase extraction (ASPEC). Residues were analyzed with a reversed-phase LC-MS/MS using a positive-ion electrospray ionisation (ESI). Isotope-labelled leucomalachite green (LMG-D5) was used as an internal standard for the quantification of LMG residues. The related dye, brilliant green (BG) was used as an instrumental standard. Identification and quantification of analytes were based on the ion transitions monitored by multiple reaction monitoring (MRM). The decision limit (CCalpha) for MG and LMG was 0.13 and 0.16 microgkg(-1). The respective detection capabilities (CCbeta) were 0.22 and 0.27 microgkg(-1). The absolute recovery (repeatability SD(r)) was in the range of 58-65% (7.8-11.2%) for MG and 59-68% (9.7-16.9%) for LMG. LMG was quantified also based on the internal standard, giving a recovery (repeatability SD(r)) of 103-110% (4.8-9.3%). The method was further evaluated by analyzing a total of 34 fish residue monitoring samples, of which eight samples were found to be non-compliant containing low residues of LMG.  相似文献   

13.
A sensitive and selective liquid chromatography-tandem spectrometry method for the determination of zolmitriptan was developed and validated over the linearity range 0.05-30 ng/ml with 0.5 ml of plasma using diphenhydramine as the internal standard. Liquid-liquid extraction using a mixture of diethyl ether and dichloromethane was used to extract the drug and the internal standard from plasma. The mass spectrometer was operated under the selected reaction monitoring (SRM) mode using the atmospheric pressure chemical ionization (APCI) technique. The instrument parameters were optimized to obtain 3.0 min run time. The mobile phase consisted of acetonitrile-water-formic acid (70:30:0.5), at a flow rate of 0.5 ml/min. In positive mode, zolmitriptan produced a protonated precursor ion at m/z 288 and a corresponding product ion at m/z 58. And internal standard produced a protonated precursor ion at m/z 256 and a corresponding product ion at m/z 167. The inter- and intra-day precision (%R.S.D.) were less than 8.5% and accuracy (%error) was less than -2.5%. The method had a lower limit of quantification of 0.05 ng/ml for zolmitriptan, which offered increased sensitivity and selectivity of analysis, compared with existing methods. The method was successfully applied to a pharmacokinetic study of zolmitriptan after an oral administration of 5 mg zolmitriptan to 20 healthy volunteers.  相似文献   

14.
A rapid, sensitive and specific method was developed for the quantification of valacyclovir and acyclovir in human plasma. Sample preparation was performed by protein precipitation with acetonitrile followed by filtration. Valacyclovir, acyclovir and ganciclovir (internal standard) were separated isocratically on a reversed-phase porous graphitized carbon analytical column (2.1 mm x 125.0 mm i.d., particle size 5 microm), using a mobile phase of acetonitrile/water with 0.05% (v/v) diethylamine (50:50, v/v) at a flow rate of 0.15 mL min(-1) in 4.0 min. Detection was performed by negative electrospray ionization using the selected ion monitoring mode of the deprotonated molecular ions at m/z 323.0 for valacyclovir, 224.0 for acyclovir and 254.0 for ganciclovir. The assay had linear calibration curves over the range 0.020-0.800 microg mL(-1) for valacyclovir and 0.100-20.00 microg mL(-1) for acyclovir. Accuracy and precision were within the acceptance limit of 15%. The method was successfully applied to the analysis of plasma samples obtained from patients after oral administration of valacyclovir.  相似文献   

15.
A high-performance liquid chromatography (LC-MS) method has been developed and validated for the determination of dexamethasone in dried blood spot (DBS) samples. For the preparation of DBS samples whole blood spiked with analyte was used to produce 30μl blood spots on specimen collection cards. An 8mm disc was cut from the DBS sample and extracted using a combination of methanol: water (70:30, v/v) containing the internal standard, triamcinolone acetonide. Extracts were centrifuged and chromatographic separation was achieved using a Zorbax Eclipse Plus C18 column using gradient elution with a mobile phase of acetonitrile and water with formic acid at a flow rate of 0.2ml/min. LC-MS detection was conducted with single ion monitoring using target ions at m/z 393.1 for dexamethasone and 435.1 for the internal standard. The developed method was linear within the tested calibration range of 15-800ng/ml. The overall extraction recovery of dexamethasone from DBS samples was 99.3% (94.3-105.7%). The accuracy (relative error) and precision (coefficient of variation) values were within the pre-defined limits of ≤15% at all concentrations. Factors with potential to affect drug quantification measurements such as blood haematocrit, the volume of blood applied onto the collection card and spotting device were investigated. Although a haematocrit related effect was apparent, the assay accuracy and precision values remained within the 15% variability limit with fluctuations in haematocrit of ±5%. Variations in the volume of blood spotted did not appear to affect the performance of the developed assay. Similar observations were made regarding the spotting device used. The methodology has been applied to determine levels of dexamethasone in DBS samples collected from premature neonates. The measured concentrations were successfully evaluated using a simple 1-compartment pharmacokinetic model. Requiring only a microvolume (30μl) blood sample for analysis, the developed assay is particularly suited to pharmacokinetic studies involving paediatric populations.  相似文献   

16.
An analytical method based on liquid chromatography with positive ion electrospray ionization (ESI) coupled to tandem mass spectrometry detection (LC-MS/MS) was developed for the determination of a potent 5-HT(1B/1D) receptor agonist, rizatriptan in human plasma using granisetron as the internal standard. The analyte and internal standard were isolated from 100 microL plasma samples by liquid-liquid extraction (LLE) and chromatographed on a Lichrospher C18 column (4.6mm x 50mm, 5 microm) with a mobile phase consisting of acetonitrile-10mM aqueous ammonium acetate-acetic acid (50:50:0.5, v/v/v) pumped at 1.0 mL/min. The method had a chromatographic total run time of 2 min. A Varian 1200 L electrospray tandem mass spectrometer equipped with an electrospray ionization source was operated in selected reaction monitoring (SRM) mode with the precursor-to-product ion transitions m/z 270-->201 (rizatriptan) and 313.4-->138 (granisetron) used for quantitation. The assay was validated over the concentration range of 0.05-50 ng/mL and was found to have acceptable accuracy, precision, linearity, and selectivity. The mean extraction recovery from spiked plasma samples was above 98%. The intra-day accuracy of the assay was within 12% of nominal and intra-day precision was better than 13% C.V. Following a 10mg dose of the compound administered to human subjects, mean concentrations of rizatriptan ranged from 0.2 to 70.6 ng/mL in plasma samples collected up to 24h after dosing. Inter-day accuracy and precision results for quality control samples run over a 5-day period alongside clinical samples showed mean accuracies of within 12% of nominal and precision better than 9.5% C.V.  相似文献   

17.
We describe a liquid chromatography-tandem mass spectrometric method (LC-MS/MS) for levocetirizine quantification (I) in human plasma. Sample preparation was made using a fexofenadine (II) addition as internal standard (IS), liquid-liquid extraction using cold dichloromethane, and dissolving the final extract in acetonitrile. I and II (IS) were injected in a C18 column and the mobile phase composed of acetonitrile:water:formic acid (80.00:19.90:0.10, v/v/v) and monitored using positive electrospray source with tandem mass spectrometry analyses. The selected reaction monitoring (SRM) was set using precursor ion and product ion combinations of m/z 389>201 for I and m/z 502>467 for II. The limit of quantification and the dynamic range achieved were 0.5ng/mL and 0.5-500.0ng/mL. Validation results on linearity, specificity, accuracy, precision and stability, as well as its application to the analysis of plasma samples taken up to 48h after oral administration of 5mg of levocetirizine dichloridrate in healthy volunteers demonstrate its applicability to bioavailability studies.  相似文献   

18.
Bestatin is a low molecular weight aminopeptidase inhibitor originally isolated from culture filtrates of Streptomyces olivoreticuli. We have developed a sensitive, specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the quantitative determination of bestatin in rat plasma using granisetron as the internal standard. The analyte and internal standard were isolated from 50 microL plasma samples by solid phase extraction (SPE). Reverse-phase HPLC separation was accomplished on a Lichrospher C18 column (4.6 mm x 50 mm, 5 microm) with a mobile phase composed of methanol-water-formic acid (70:30:0.5, v/v/v) at a flow rate of 0.8 mL/min. The method had a chromatographic total run time of 3 min. A Varian 1200L electrospray tandem mass spectrometer equipped with an electrospray ionization source was operated in selected reaction monitoring (SRM) mode with the precursor-to-product ion transitions m/z 309.2-->120.0 (bestatin) and 313.4-->138.0 (granisetron) used for quantitation. The method was sensitive with a lower limit of quantitation (LLOQ) of 5 ng/mL, with good linearity (r2 >or= 0.999) over the linear range of 5-2000 ng/mL. All the validation data, such as accuracy, precision, and inter-day repeatability, were within the required limits. The method was successfully applied to pharmacokinetic study of bestatin in rats.  相似文献   

19.
Letosteine has been found to be effective in treating patients with chronic bronchopneumopathies in clinical practice. To provide robust support for its pharmacokinetic and clinical studies, a rapid and sensitive method based on liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) was developed and validated for the analysis of letosteine in plasma samples. After protein precipitation, the plasma samples were separated on a reversed-phase C(18) column in less than 1.5 min. The LC-MS/MS system was performed in the positive ion multiple-reaction-monitoring (MRM) mode to produce intensive product ions of m/z 280.1→160.0 for letosteine and m/z 248.1→121.1 for the internal standard, tinidazole. The method was found to have excellent linearity (r ≥ 0.9974), precision (RSD ≤ 5.83%), extraction recovery (71.8-73.0%) and stability (RE, -8.45% to 9.03%) over a concentration range of 0.1140-152.0 μgL(-1). Compared to the previous published radioactive method, LC-MS/MS method showed many advantages including shorter analysis time, simpler preparation procedure, increased sensitivity as well as lower safety risks. In addition, this method was successfully applied to study the pharmacokinetics of letosteine following a single and multiple dose oral administration in Chinese healthy volunteers.  相似文献   

20.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method has been developed and fully validated to determine HS270, a new histone deacetylase (HDAC) inhibitor, in rat plasma using SAHA as the internal standard (IS). After a single step liquid-liquid extraction with acetoacetate, analytes were subjected to LC-MS/MS analysis using positive electro-spray ionization (ESI(+)) under selected reaction monitoring mode (SRM). The chromatographic separation was achieved on a Hypurity C(18) column (50 mm × 2.1 mm, i.d., 5 μm). The MS/MS detection was conducted by monitoring the fragmentation of m/z 392.3→100.1 for HS270, m/z 265.1→232.1 for IS. The method had a chromatographic running time of 2.5 min and linear calibration curves over the concentrations of 0.5-1000 ng/mL. The recovery of the method was 70.8-82.5% and the lower limit of quanti?cation (LLOQ) was 0.5 ng/mL. The intra- and inter-batch precisions were less than 15% for all quality control samples at concentrations of 1.0, 100.0, and 750.0 ng/mL. The validated LC-MS/MS method has successfully applied to a HS270 pharmacokinetic study after oral doses of 25, 50, 100, 200 mg/kg, and i.v. dose of 5 mg/kg to rats.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号