共查询到20条相似文献,搜索用时 9 毫秒
1.
Composite self-excited PZT-glass cantilevers (5 and 3 mm in length, 1.8 and 2.0 mm wide) were fabricated and their resonance characteristics were determined in air and at 1 mm liquid immersion. In air, resonance occurred at 65.8 and 63.4 kHz for the two cantilevers used in this paper. Monoclonal antibody (MAb) specific to the pathogen Escherichia coli (E. coli) O157:H7 was immobilized at the cantilever glass tip, and then exposed to pathogen in the concentration range of 7x10(2) to 7x10(7)bacteria/mL. Resonance of the second mode decreased due to pathogen attachment in accordance with a proposed kinetic model. The specific attachment rate constant was found to be 3x10(-9) to 5x10(-9) min-1 (cell/mL)-1. Exposure to a mixed population containing both a pathogenic and non-pathogenic strain showed that the antibody-immobilized cantilever is highly selective, thus demonstrating its usefulness for detecting water-borne pathogens. 相似文献
2.
Detection and quantification of Escherichia coli O157:H7 in environmental samples by real-time PCR 总被引:4,自引:0,他引:4
AIMS: To apply the real-time Polymerase chain reaction (PCR) method to detect and quantify Escherichia coli O157:H7 in soil, manure, faeces and dairy waste washwater. METHODS AND RESULTS: Soil samples were spiked with E. coli O157:H7 and subjected to a single enrichment step prior to multiplex PCR. Other environmental samples suspected of harbouring E.coli O157:H7 were also analysed. The sensitivity of the primers was confirmed with DNA from E.coli O157:H7 strain 3081 spiked into soil by multiplex PCR assay. A linear relationship was measured between the fluorescence threshold cycle (C T ) value and colony counts (CFU ml(-1)) in spiked soil and other environmental samples. The detection limit for E.coli O157:H7 in the real-time PCR assay was 3.5 x 10(3) CFU ml(-1) in pure culture and 2.6 x 10(4) CFU g(-1) in the environmental samples. Use of a 16-h enrichment step for spiked samples enabled detection of <10 CFU g(-1) soil. E. coli colony counts as determined by the real-time PCR assay, were in the range of 2.0 x 10(2) to 6.0 x 10(5) CFU PCR (-1) in manure, faeces and waste washwater. CONCLUSIONS: The real-time PCR-based assay enabled sensitive and rapid quantification of E. coli O157:H7 in soil and other environmental samples. SIGNIFICANCE AND IMPACT OF THE STUDY: The ability to quantitatively determine cell counts of E.coli O157:H7 in large numbers of environmental samples, represents considerable advancement in the area of pathogen quantification for risk assessment and transport studies. 相似文献
3.
Evaluation of a PCR detection method for Escherichia coli O157:H7/H- bovine faecal samples 总被引:1,自引:0,他引:1
Al-Ajmi D Padmanabha J Denman SE Gilbert RA Al Jassim RA McSweeney CS 《Letters in applied microbiology》2006,42(4):386-391
AIMS: Combinations of PCR primer sets were evaluated to establish a multiplex PCR method to specifically detect Escherichia coli O157:H7 genes in bovine faecal samples. METHODS AND RESULTS: A multiplex PCR method combining three primer sets for the E. coli O157:H7 genes rfbE, uidA and E. coli H7 fliC was developed and tested for sensitivity and specificity with pure cultures of 27 E. coli serotype O157 strains, 88 non-O157 E. coli strains, predominantly bovine in origin and five bacterial strains other than E. coli. The PCR method was very specific in the detection of E. coli O157:H7 and O157:H- strains, and the detection limit in seeded bovine faecal samples was <10 CFU g(-1) faeces, following an 18-h enrichment at 37 degrees C, and could be performed using crude DNA extracts as template. CONCLUSIONS: A new multiplex PCR method was developed to detect E. coli O157:H7 and O157:H-, and was shown to be highly specific and sensitive for these strains both in pure culture and in crude DNA extracts prepared from inoculated bovine faecal samples. SIGNIFICANCE AND IMPACT OF THE STUDY: This new multiplex PCR method is suitable for the rapid detection of E. coli O157:H7 and O157:H- genes in ruminant faecal samples. 相似文献
4.
Detection of Escherichia coli O157:H7 using immunomagnetic separation and absorbance measurement 总被引:6,自引:0,他引:6
An assay system for detection of Escherichia coli O157:H7 was developed based on immunomagnetic separation of the target pathogen from samples and absorbance measurement of p-nitrophenol at 400 nm from p-nitrophenyl phosphate hydrolysis by alkaline phosphatase (EC 3.1.3.1) on the "sandwich" structure complexes (antibodies coated onto micromagnetic beads--E. coli O157:H7-antibodies conjugated with the enzyme) formed on the microbead surface. The effects of immunoreaction time, phosphate buffer concentration, pH and temperature on the immunomagnetic separation of E. coli O157:H7 from samples were determined and the conditions used for the separation were 1-h reaction time, 1.0 x 10(-2) M PBS, pH 8.0 and 33 degrees C in this system. The effects of MgCl(2) concentration, Tris buffer concentration, pH and temperature on the activity of alkaline phosphatase conjugated on the immuno-"sandwich" structure complexes were investigated after immunomagnetic separation of the target pathogen and the conditions used for the enzymatic amplification were 1.0 x 10(-4) M MgCl(2), 1.0 M Tris buffer, pH 8.0, 28 degrees C and 30-min reaction time during the assay. The selectivity of the system was examined and no interference from the other pathogens including Salmonella typhimurium, Campylobacter jejuni and Listeria monocytogenes was observed. Its working range was from 3.2 x 10(2) to 3.2 x 10(4) CFU/ml, and the relative standard deviation was 2.5-9.9%. The total detection time was less than 2 h. 相似文献
5.
In this study, we identified the iron-transport systems of Escherichia coli O157:H7 strain EDL933. This strain synthesized and transported enterobactin and had a ferric citrate transport system but lacked the ability to produce or use aerobactin. It used haem and haemoglobin, but not transferrin or lactoferrin, as iron sources. We cloned the gene encoding an iron-regulated haem-transport protein and showed that this E. coli haem-utilization gene ( chuA ) encoded a 69 kDa outer membrane protein that was synthesized in response to iron limitation. Expression of this protein in a laboratory strain of E. coli was sufficient for utilization of haem or haemoglobin as iron sources. Mutation of the chromosomal chuA and tonB genes in E. coli O157:H7 demonstrated that the utilization of haemin and haemoglobin was ChuA- and TonB-dependent. Nucleotide sequence analysis of chuA revealed features characteristic of TonB-dependentFur-regulated, outer membrane iron-transport proteins. It was highly homologous to the shuA gene of Shigella dysenteriae and less closely related to hemR of Yersinia enterocolitica and hmuR of Yersinia pestis . A conserved Fur box was identified upstream of the chuA gene, and regulation by Fur was confirmed. 相似文献
6.
AIMS: To evaluate the suitability of a multiplex PCR-based assay for sensitive and rapid detection of Escherichia coli O157:H7 in soil and water. METHODS AND RESULTS: Soil and water samples were spiked with E. coli O157:H7 and subjected to two stages of enrichment prior to multiplex PCR. Detection sensitivities were as high as 1 cfu ml(-1) drinking water and 2 cfu g(-1) soil. Starvation of E. coli O157:H7 for 35 d prior to addition to soil did not affect the ability of the assay to detect initial cell numbers as low as 10 cfu g(-1) soil. Use of an 8-h primary enrichment enabled detection of as few as 6 cfu g(-1) soil, and 10(4) cfu g(-1) soil with a 6-h primary enrichment. When soil was inoculated with 10(5) cfu g(-1), the PCR assay indicated persistence of E. coli O157:H7 during a 35 d incubation. However, when soil was inoculated with lower numbers of pathogen, PCR amplification signals indicated survival to be dependent on cell concentration. CONCLUSIONS: A multiplex PCR-based assay, in combination with an enrichment strategy enabled sensitive and rapid detection of E. coli O157:H7 in soil and water. SIGNIFICANCE AND IMPACT OF THE STUDY: The ability to sensitively detect E.coli O157:H7 in environmental material within one working day represents a considerable advancement over alternative more time-consuming methods for detection of this pathogen. 相似文献
7.
A unique open reading frame (ORF) Z3276 was identified as a specific genetic marker for E. coli O157:H7. A qPCR assay was developed for detection of E. coli O157:H7 by targeting ORF Z3276. With this assay, we can detect as low as a few copies of the genome of DNA of E. coli O157:H7. The sensitivity and specificity of the assay were confirmed by intensive validation tests with a large number of E. coli O157:H7 strains (n = 369) and non-O157 strains (n = 112). Furthermore, we have combined propidium monoazide (PMA) procedure with the newly developed qPCR protocol for selective detection of live cells from dead cells. Amplification of DNA from PMA-treated dead cells was almost completely inhibited in contrast to virtually unaffected amplification of DNA from PMA-treated live cells. Additionally, the protocol has been modified and adapted to a 96-well plate format for an easy and consistent handling of a large number of samples. This method is expected to have an impact on accurate microbiological and epidemiological monitoring of food safety and environmental source. 相似文献
8.
《Journal of biological dynamics》2013,7(2):1052-1066
This study reports analysis of faecal shedding dynamics in cattle for three Escherichia coli O157:H7 (ECO157) strains (S1, S2 and S3) of different genotype and ecological history, using experimental inoculation data. The three strains were compared for their shedding frequency and level of ECO157 in faeces. A multistate Markov chain model was used to compare shedding patterns of S1 and S2. Strains S1 and S2 were detected seven to eight times more often and at 104 larger levels than strain S3. Strains S1 and S2 had similar frequencies and levels of shedding. However, the total time spent in the shedding state during colonization was on average four times longer for S1 (15 days) compared to S2 (4 days). These results indicate that an ECO157 strain effect on the frequency, level, pattern and the duration of faecal shedding may need to be considered in control of ECO157 in the cattle reservoir. 相似文献
9.
10.
Son Radu Shahilah Abdul Mutalib Gulam Rusul Zainori Ahmad Tadaaki Morigaki Norio Asai Yung Bu Kim Jun Okuda Mitsuaki Nishibuchi 《Applied microbiology》1998,64(3):1153-1156
Twelve strains of Escherichia coli O157:H7 were isolated from 9 of 25 beef samples purchased from retail stores in Malaysia. These strains produced Shiga toxin 2 with or without Shiga toxin 1 and had the eae gene and a 60-MDa plasmid. The antibiograms and the profiles of the arbitrarily primed PCR of the strains were diverse, suggesting that the strains may have originated from diverse sources. 相似文献
11.
Wenhe Wu Jie Zhang Meiqin Zheng Yuhong Zhong Jie Yang Yuhong Zhao Wenping Wu Wei Ye Jie Wen Qi Wang Jianxin Lu 《PloS one》2012,7(11)
Background
An aptamer based biosensor (aptasensor) was developed and evaluated for rapid colorimetric detection of Escherichia coli (E. coli) O157:H7.Methodology/Principal Findings
The aptasensor was assembled by modifying the truncated lipopolysaccharides (LPS)-binding aptamer on the surface of nanoscale polydiacetylene (PDA) vesicle using peptide bonding between the carboxyl group of the vesicle and the amine group of the aptamer. Molecular recognition between E. coli O157:H7 and aptamer at the interface of the vesicle lead to blue-red transition of PDA which was readily visible to the naked eyes and could be quantified by colorimetric responses (CR). Confocal laser scanning microscope (CLSM) and transmission electron microscopy (TEM) was used to confirm the specific interactions between the truncated aptamer and E. coli O157:H7. The aptasensor could detect cellular concentrations in a range of 104∼ 108 colony-forming units (CFU)/ml within 2 hours and its specificity was 100% for detection of E. coli O157:H7. Compared with the standard culture method, the correspondent rate was 98.5% for the detection of E. coli O157:H7 on 203 clinical fecal specimens with our aptasensor.Conclusions
The new aptasensor represents a significant advancement in detection capabilities based on the combination of nucleic acid aptamer with PDA vesicle, and offers a specific and convenient screening method for the detection of pathogenic bacteria. This technic could also be applied in areas from clinical analysis to biological terrorism defense, especially in low-resource settings. 相似文献12.
Virulence and pathogenicity of an Escherichia coli O157:H7 sorbitol-positive mutant were investigated with an infant rabbit animal model as well as a battery of in vitro assays. Total cell lysate protein profiles, outer membrane protein profiles, plasmid profiles, and levels of cytotoxic activity against Vero cells were similar in the wild-type and mutant strains. Both adhered to intestinal epithelial cells in culture and reacted with fluorescein isothiocyanate-labeled antiserum against E. coli O157:H7. The mutant appeared to be similar to the wild type in all respects except in its ability to ferment sorbitol. [14C]sorbitol uptake and sorbitol-6-phosphate dehydrogenase activities were notably increased in the mutant strain. Diarrhea developed in rabbits administered the wild-type strain and in those fed the sorbitol-positive mutant. There was greater bacterial attachment and mucosal damage in the cecum and large intestine than in the small intestine. Scanning electron microscopy revealed bacteria adhering as single cells and as aggregates closely associated with mucus. Mucosal lesions consisted of areas of tissue necrosis with sloughing of epithelial cells. By transmission electron microscopy, electron-dense necrotic epithelial cells were visible in areas where bacteria were present, and epithelial cell debris containing bacteria was observed between the villar luminal surfaces. Light microscopy of epithelial cells of intestinal sections of infected rabbits revealed noticeable vacuolation and spherical, pyknotic nuclei. These data indicate that the sorbitol-negative phenotype is not associated with the pathogenicity of E. coli O157:H7. 相似文献
13.
Powell Mark R. Ebel Eric Schlosser Wayne Walderhaug Mark Kause Janell 《Quantitative Microbiology》2000,2(2):141-163
Escherichia coli O157:H7 is an emerging food and waterborne pathogen in the U.S. and internationally. The objective of this work was to develop a dose-response model for illness by this organism that bounds the uncertainty in the dose-response relationship. No human clinical trial data are available for E. coli O157:H7, but such data are available for two surrogate pathogens: enteropathogenic E. coli (EPEC) and Shigella dysenteriae. E. coli O157:H7 outbreak data provide an initial estimate of the most likely value of the dose-response relationship within the bounds of an envelope defined by beta-Poisson dose-response models fit to the EPEC and S. dysenteriae data. The most likely value of the median effective dose for E. coli O157:H7 is estimated to be approximately 190[emsp4 ]000 colony forming units (cfu). At a dose level of 100[emsp4 ]cfu, the median response predicted by the model is six percent. 相似文献
14.
Kai E Ikebukuro K Hoshina S Watanabe H Karube I 《FEMS immunology and medical microbiology》2000,29(4):283-288
A method for the rapid detection of verotoxin-producing Escherichia coli O157:H7 in stools was evaluated. Strains possessing Shiga toxin-2 (stx-2) genes were isolated from stool samples and amplified using oligonucleotide primers. Stools spiked with cultured E. coli O157:H7 (strain 298 or strain 1646) were detected to be polymerase chain reaction (PCR) positive at 10(2) cfu per 0.1 g of stool. Stool samples from patients and healthy carriers showed a high correlation between positive results for a PCR and the presence of verotoxin-producing E. coli O157:H7, confirmed by isolation of serotype O157:H7 on sorbitol MacConkey medium (10 of 10 stool samples). These PCR products could be detected using a BIAcore 2000 surface plasmon resonance device using peptide nucleic acid as a sensor probe. In this report we use this method for the rapid detection of DNA from significant pathogenic organisms. 相似文献
15.
16.
Brichta-Harhay DM Arthur TM Bosilevac JM Guerini MN Kalchayanand N Koohmaraie M 《Journal of applied microbiology》2007,103(5):1657-1668
AIM: To develop and validate high throughput methods for the direct enumeration of viable and culturable Salmonella and Escherichia coli O157:H7 in ground beef, carcass, hide and faecal (GCHF) samples from cattle. METHODS AND RESULTS: The hydrophobic grid membrane filtration (HGMF) method and the spiral plate count method (SPCM) were evaluated as rapid tools for the estimation of pathogen load using GCHF samples spiked with known levels of Salmonella serotype Typhimurium. Validation studies showed that for a single determination of each sample type the low end of the detection limits were approx. 2.0 x 10(0) CFU g(-1) for ground beef, 5.0 x 10(-1) CFU (100 cm(2))(-1) for Salmonella and 8.0 x 10(-1) CFU (100 cm(2))(-1) for E. coli O157:H7 on carcasses, 4.0 x 10(1) CFU (100 cm(2))(-1) for hide and 2.0 x 10(2) CFU g(-1) for faecal samples. In addition, ground beef (n = 609), carcass (n = 1520) and hide (n = 3038) samples were collected from beef-processing plants and faecal samples (n = 3190) were collected from feed-lot cattle, and these samples were tested for the presence of Salmonella and E. coli O157:H7 by enrichment and enumeration methods. CONCLUSIONS: The direct enumeration methods described here are amenable to high throughput sample processing and were found to be cost-effective alternatives to other enumeration methods for the estimation of Salmonella and E. coli O157:H7, in samples collected during cattle production and beef processing. SIGNIFICANCE AND IMPACT OF THE STUDY: Use of the methods described here would allow for more routine testing and quantification data collection, providing useful information about the effectiveness of beef processing intervention strategies. 相似文献
17.
Direct PCR detection of Escherichia coli O157:H7 总被引:2,自引:0,他引:2
AIMS: This paper reports a simple, rapid approach for the detection of Shiga toxin (Stx)-producing Escherichia coli (STEC). METHODS AND RESULTS: Direct PCR (DPCR) obviates the need for the recovery of cells from the sample or DNA extraction prior to PCR. Primers specific for Stx-encoding genes stx1 and stx2 were used in DPCR for the detection of E. coli O157:H7 added to environmental water samples and milk. CONCLUSIONS: PCR reactions containing one cell yielded a DPCR product. SIGNIFICANCE AND IMPACT OF THE STUDY: This should provide an improved method to assess contamination of environmental and other samples by STEC and other pathogens. 相似文献
18.
Rapid Detection of Escherichia coli O157:H7 with Multiplex Real-Time PCR Assays 总被引:4,自引:0,他引:4 下载免费PDF全文
A SYBR Green LightCycler PCR assay using a single primer pair allowed simultaneous detection of stx1 and/or stx2 of Escherichia coli O157:H7. A distinct sequence of the Shiga-like toxin genes was amplified to yield products of 227 and/or 224 bp, respectively. The two products were distinguished by melting point curve analysis. 相似文献
19.
The effect of anaerobic cultures of faecal microflora from adult birds on colonization with Escherichia coli O157: H7 was evaluated in two breeds of young broiler and layer chicks. Protection against this pathogen was evident in both types of chicks, but was better in layers. 相似文献
20.
Zhemin Zhou Xiaomin Li Bin Liu Lothar Beutin Jianguo Xu Yan Ren Lu Feng Ruiting Lan Peter R. Reeves Lei Wang 《PloS one》2010,5(1)
There are 29 E. coli genome sequences available, mostly related to studies of species diversity or mode of pathogenicity, including two genomes of the well-known O157:H7 clone. However, there have been no genome studies of closely related clones aimed at exposing the details of evolutionary change. Here we sequenced the genome of an O55:H7 strain, closely related to the major pathogenic O157:H7 clone, with published genome sequences, and undertook comparative genomic and proteomic analysis. We were able to allocate most differences between the genomes to individual mutations, recombination events, or lateral gene transfer events, in specific lineages. Major differences include a type II secretion system present only in the O55:H7 chromosome, fewer type III secretion system effectors in O55:H7, and 19 phage genomes or phagelike elements in O55:H7 compared to 23 in O157:H7, with only three common to both. Many other changes were found in both O55:H7 and O157:H7 lineages, but in general there has been more change in the O157:H7 lineages. For example, we found 50% more synonymous mutational substitutions in O157:H7 compared to O55:H7. The two strains also diverged at the proteomic level. Mutational synonymous SNPs were used to estimate a divergence time of 400 years using a new clock rate, in contrast to 14,000 to 70,000 years using the traditional clock rates. The same approaches were applied to three closely related extraintestinal pathogenic E. coli genomes, and similar levels of mutation and recombination were found. This study revealed for the first time the full range of events involved in the evolution of the O157:H7 clone from its O55:H7 ancestor, and suggested that O157:H7 arose quite recently. Our findings also suggest that E. coli has a much lower frequency of recombination relative to mutation than was observed in a comparable study of a Vibrio cholerae lineage. 相似文献