首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.

Purpose

To investigate image quality and radiation dose of CT coronary angiography (CTCA) scanned using automatic tube current modulation (ATCM) and reconstructed by strong adaptive iterative dose reduction three-dimensional (AIDR3D).

Methods

Eighty-four consecutive CTCA patients were collected for the study. All patients were scanned using ATCM and reconstructed with strong AIDR3D, standard AIDR3D and filtered back-projection (FBP) respectively. Two radiologists who were blinded to the patients'' clinical data and reconstruction methods evaluated image quality. Quantitative image quality evaluation included image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). To evaluate image quality qualitatively, coronary artery is classified into 15 segments based on the modified guidelines of the American Heart Association. Qualitative image quality was evaluated using a 4-point scale. Radiation dose was calculated based on dose-length product.

Results

Compared with standard AIDR3D, strong AIDR3D had lower image noise, higher SNR and CNR, their differences were all statistically significant (P<0.05); compared with FBP, strong AIDR3D decreased image noise by 46.1%, increased SNR by 84.7%, and improved CNR by 82.2%, their differences were all statistically significant (P<0.05 or 0.001). Segments with diagnostic image quality for strong AIDR3D were 336 (100.0%), 486 (96.4%), and 394 (93.8%) in proximal, middle, and distal part respectively; whereas those for standard AIDR3D were 332 (98.8%), 472 (93.7%), 378 (90.0%), respectively; those for FBP were 217 (64.6%), 173 (34.3%), 114 (27.1%), respectively; total segments with diagnostic image quality in strong AIDR3D (1216, 96.5%) were higher than those of standard AIDR3D (1182, 93.8%) and FBP (504, 40.0%); the differences between strong AIDR3D and standard AIDR3D, strong AIDR3D and FBP were all statistically significant (P<0.05 or 0.001). The mean effective radiation dose was (2.55±1.21) mSv.

Conclusion

Compared with standard AIDR3D and FBP, CTCA with ATCM and strong AIDR3D could significantly improve both quantitative and qualitative image quality.  相似文献   

2.

Objective

To test the hypothesis that wide area detector face transplant surgical planning CT angiograms with simulated lower radiation dose and iterative reconstruction (AIDR3D) are comparable in image quality to those with standard tube current and filtered back projection (FBP) reconstruction.

Materials and Methods

The sinograms from 320-detector row CT angiography of four clinical candidates for face transplantation were processed utilizing standard FBP, FBP with simulated 75, 62, and 50% tube current, and AIDR3D with corresponding dose reduction. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured at muscle, fat, artery, and vein. Image quality for each reconstruction strategy was assessed by two independent readers using a 4-point scale.

Results

Compared to FBP, the median SNR and CNR for AIDR3D images were higher at all sites for all 4 different tube currents. The AIDR3D with simulated 50% tube current achieved comparable SNR and CNR to FBP with standard dose (median muscle SNR: 5.77 vs. 6.23; fat SNR: 6.40 vs. 5.75; artery SNR: 43.8 vs. 45.0; vein SNR: 54.9 vs. 55.7; artery CNR: 38.1 vs. 38.6; vein CNR: 49.0 vs. 48.7; all p-values >0.19). The interobserver agreement in the image quality score was good (weighted κ = 0.7). The overall score and the scores for smaller arteries were significantly lower when FBP with 50% dose reduction was used. The AIDR3D reconstruction images with 4 different simulated doses achieved a mean score ranging from 3.68 to 3.82 that were comparable to the scores from images reconstructed using FBP with original dose (3.68–3.77).

Conclusions

Simulated radiation dose reduction applied to clinical CT angiography for face transplant planning suggests that AIDR3D allows for a 50% reduction in radiation dose, as compared to FBP, while preserving image quality.  相似文献   

3.

Objectives

To evaluate how well patients with coronary stents accept combined coronary computed tomography angiography (CTA) and myocardial CT perfusion (CTP) compared with conventional coronary angiography (CCA).

Background

While combined CTA and CTP may improve diagnostic accuracy compared with CTA alone, patient acceptance of CTA/CTP remains to be defined.

Methods

A total of 90 patients with coronary stents prospectively underwent CTA/CTP (both with contrast agent, CTP with adenosine) and CCA as part of the CARS-320 study. In this group, an intraindividual comparison of patient acceptance of CTA, CTP, and CCA was performed.

Results

CTP was experienced to be significantly more painful than CTA (p<0.001) and was associated with a higher frequency of dyspnea (p<0.001). Comparison of CTA/CTP with CCA revealed no significant differences in terms of pain (p = 0.141) and comfort (p = 0.377). Concern before CTA/CTP and CCA and overall satisfaction were likewise not significantly different (p = 0.097 and p = 0.123, respectively). Nevertheless, about two thirds (n = 60, 68%) preferred CTA/CTP to CCA (p<0.001). Moreover, patients felt less helpless during CTA/CTP than during CCA (p = 0.026). Lack of invasiveness and absence of pain were the most frequently mentioned advantages of CTA/CTP over CCA in our patient population.

Conclusions

CCA and combined CTA/CTP are equally well accepted by patients; however, more patients prefer CTA/CTP. CTP was associated with more intense pain than CTA and more frequently caused dyspnea than CTA alone.

Trial Registration

ClinicalTrials.gov NCT00967876  相似文献   

4.

Objective

To investigate image quality and radiation dose of CT colonography (CTC) with adaptive iterative dose reduction three-dimensional (AIDR3D).

Methods

Ten segments of porcine colon phantom were collected, and 30 pedunculate polyps with diameters ranging from 1 to 15 mm were simulated on each segment. Image data were acquired with tube voltage of 120 kVp, and current doses of 10 mAs, 20 mAs, 30 mAs, 40 mAs, 50 mAs, respectively. CTC images were reconstructed using filtered back projection (FBP) and AIDR3D. Two radiologists blindly evaluated image quality. Quantitative evaluation of image quality included image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Qualitative image quality was evaluated with a five-score scale. Radiation dose was calculated based on dose-length product. Ten volunteers were examined supine 50 mAs with FBP and prone 20 mAs with AIDR3D, and image qualities were assessed. Paired t test was performed for statistical analysis.

Results

For 20 mAs with AIDR3D and 50 mAs with FBP, image noise, SNRs and CNRs were (16.4 ± 1.6) HU vs. (16.8 ± 2.6) HU, 1.9 ± 0.2 vs. 1.9 ± 0.4, and 62.3 ± 6.8 vs. 62.0 ± 6.2, respectively; qualitative image quality scores were 4.1 and 4.3, respectively; their differences were all not statistically significant. Compared with 50 mAs with FBP, radiation dose (1.62 mSv) of 20 mAs with AIDR3D was decreased by 60.0%. There was no statistically significant difference in image noise, SNRs, CNRs and qualitative image quality scores between prone 20 mAs with AIDR3D and supine 50 mAs with FBP in 10 volunteers, the former reduced radiation dose by 61.1%.

Conclusion

Image quality of CTC using 20 mAs with AIDR3D could be comparable to standard 50 mAs with FBP, radiation dose of the former reduced by about 60.0% and was only 1.62 mSv.  相似文献   

5.

Background

The purpose of the present study was to compare the image quality of spinal magnetic resonance (MR) imaging performed on a high-field horizontal open versus a short-bore MR scanner in a randomized controlled study setup.

Methods

Altogether, 93 (80% women, mean age 53) consecutive patients underwent spine imaging after random assignement to a 1-T horizontal open MR scanner with a vertical magnetic field or a 1.5-T short-bore MR scanner. This patient subset was part of a larger cohort. Image quality was assessed by determining qualitative parameters, signal-to-noise (SNR) and contrast-to-noise ratios (CNR), and quantitative contour sharpness.

Results

The image quality parameters were higher for short-bore MR imaging. Regarding all sequences, the relative differences were 39% for the mean overall qualitative image quality, 53% for the mean SNR values, and 34–37% for the quantitative contour sharpness (P<0.0001). The CNR values were also higher for images obtained with the short-bore MR scanner. No sequence was of very poor (nondiagnostic) image quality. Scanning times were significantly longer for examinations performed on the open MR scanner (mean: 32±22 min versus 20±9 min; P<0.0001).

Conclusions

In this randomized controlled comparison of spinal MR imaging with an open versus a short-bore scanner, short-bore MR imaging revealed considerably higher image quality with shorter scanning times.

Trial Registration

ClinicalTrials.gov NCT00715806  相似文献   

6.

Purpose

To prospectively investigate the effect of using Gemstone Spectral Imaging (GSI) and adaptive statistical iterative reconstruction (ASIR) for reducing radiation and iodine contrast dose in abdominal CT patients with high BMI values.

Materials and Methods

26 patients (weight > 65kg and BMI ≥ 22) underwent abdominal CT using GSI mode with 300mgI/kg contrast material as study group (group A). Another 21 patients (weight ≤ 65kg and BMI ≥ 22) were scanned with a conventional 120 kVp tube voltage for noise index (NI) of 11 with 450mgI/kg contrast material as control group (group B). GSI images were reconstructed at 60keV with 50%ASIR and the conventional 120kVp images were reconstructed with FBP reconstruction. The CT values, standard deviation (SD), signal-noise-ratio (SNR), contrast-noise-ratio (CNR) of 26 landmarks were quantitatively measured and image quality qualitatively assessed using statistical analysis.

Results

As for the quantitative analysis, the difference of CNR between groups A and B was all significant except for the mesenteric vein. The SNR in group A was higher than B except the mesenteric artery and splenic artery. As for the qualitative analysis, all images had diagnostic quality and the agreement for image quality assessment between the reviewers was substantial (kappa = 0.684). CT dose index (CTDI) values for non-enhanced, arterial phase and portal phase in group A were decreased by 49.04%, 40.51% and 40.54% compared with group B (P = 0.000), respectively. The total dose and the injection rate for the contrast material were reduced by 14.40% and 14.95% in A compared with B.

Conclusion

The use of GSI and ASIR provides similar enhancement in vessels and image quality with reduced radiation dose and contrast dose, compared with the use of conventional scan protocol.  相似文献   

7.

Background

Replicating smallpox vaccines can cause severe complications in individuals with atopic dermatitis (AD). Prior studies evaluating Modified Vaccinia Ankara virus (MVA), a non-replicating vaccine in humans, showed a favorable safety and immunogenicity profile in healthy volunteers.

Objective

This Phase II study compared the safety and immunogenicity of MVA enrolling groups of 350 subjects with AD (SCORAD ≤ 30) and 282 healthy subjects.

Methods

Subjects were vaccinated twice with MVA, each dose given subcutaneously 4 weeks apart. Adverse events, cardiac parameters, and the development of vaccinia virus humoral immune responses were monitored.

Results

The overall safety of the vaccine was similar in both groups. Adverse events affecting skin were experienced significantly more often in subjects with AD, but the majority of these events were mild to moderate in intensity. Seroconversion rates and geometric mean titers for total and neutralizing vaccinia-specific antibodies in the AD group were non-inferior compared to the healthy subjects.

Limitations

The size of the study population limited the detection of serious adverse events occurring at a frequency less than 1%.

Conclusion

MVA has a favorable safety profile and the ability to elicit vaccinia-specific immune responses in subjects with AD.

Trial Registration

ClinicalTrials.gov NCT00316602  相似文献   

8.

Objectives

Given the importance of vision in the control of walking and evidence indicating varied practice of walking improves mobility outcomes, this study sought to examine the feasibility and preliminary efficacy of varied walking practice in response to visual cues, for the rehabilitation of walking following stroke.

Design

This 3 arm parallel, multi-centre, assessor blind, randomised control trial was conducted within outpatient neurorehabilitation services

Participants

Community dwelling stroke survivors with walking speed <0.8m/s, lower limb paresis and no severe visual impairments

Intervention

Over-ground visual cue training (O-VCT), Treadmill based visual cue training (T-VCT), and Usual care (UC) delivered by physiotherapists twice weekly for 8 weeks.Main outcome measures: Participants were randomised using computer generated random permutated balanced blocks of randomly varying size. Recruitment, retention, adherence, adverse events and mobility and balance were measured before randomisation, post-intervention and at four weeks follow-up.

Results

Fifty-six participants participated (18 T-VCT, 19 O-VCT, 19 UC). Thirty-four completed treatment and follow-up assessments. Of the participants that completed, adherence was good with 16 treatments provided over (median of) 8.4, 7.5 and 9 weeks for T-VCT, O-VCT and UC respectively. No adverse events were reported. Post-treatment improvements in walking speed, symmetry, balance and functional mobility were seen in all treatment arms.

Conclusions

Outpatient based treadmill and over-ground walking adaptability practice using visual cues are feasible and may improve mobility and balance. Future studies should continue a carefully phased approach using identified methods to improve retention.

Trial Registration

Clinicaltrials.gov NCT01600391  相似文献   

9.

Background

Cancer stem cells represent a population of immature tumor cells found in most solid tumors. Their peculiar features make them ideal models for studying drug resistance and sensitivity. In this study, we investigated whether cancer stem cells isolation and in vitro sensitivity assay are feasible in a clinical setting.

Methods

Cancer stem cells were isolated from effusions or fresh cancer tissue of 23 patients who progressed after standard therapy failure. Specific culture conditions selected for immature tumor cells that express markers of stemness. These cells were exposed in vitro to chemotherapeutic and targeted agents.

Results

Cancer stem cells were extracted from liver metastases in 6 cases (25%), lung nodules in 2 (8%), lymph node metastases in 3 (12.5%) and pleural/peritoneal/pericardial effusion in 13 (54%). Cancer stem cells were successfully isolated in 15 patients (63%), including 14 with lung cancer (93.3%). A sensitivity assay was successfully performed in 7 patients (30.4%), with a median of 15 drugs/combinations tested (range 5-28) and a median time required for results of 51 days (range 37-95).

Conclusion

The approach used for the STELLA trial allowed isolation of cancer stem cells in a consistent proportion of patients. The low percentage of cases completing the full procedure and the long median time for obtaining results highlights the need for a more efficient procedure.

Trial Registration

ClinalTrials.gov NCT01483001  相似文献   

10.

Objective

To assess the advantages of Adaptive Iterative Dose Reduction using Three Dimensional Processing (AIDR3D) for image quality improvement and dose reduction for chest computed tomography (CT).

Methods

Institutional Review Boards approved this study and informed consent was obtained. Eighty-eight subjects underwent chest CT at five institutions using identical scanners and protocols. During a single visit, each subject was scanned using different tube currents: 240, 120, and 60 mA. Scan data were converted to images using AIDR3D and a conventional reconstruction mode (without AIDR3D). Using a 5-point scale from 1 (non-diagnostic) to 5 (excellent), three blinded observers independently evaluated image quality for three lung zones, four patterns of lung disease (nodule/mass, emphysema, bronchiolitis, and diffuse lung disease), and three mediastinal measurements (small structure visibility, streak artifacts, and shoulder artifacts). Differences in these scores were assessed by Scheffe''s test.

Results

At each tube current, scans using AIDR3D had higher scores than those without AIDR3D, which were significant for lung zones (p<0.0001) and all mediastinal measurements (p<0.01). For lung diseases, significant improvements with AIDR3D were frequently observed at 120 and 60 mA. Scans with AIDR3D at 120 mA had significantly higher scores than those without AIDR3D at 240 mA for lung zones and mediastinal streak artifacts (p<0.0001), and slightly higher or equal scores for all other measurements. Scans with AIDR3D at 60 mA were also judged superior or equivalent to those without AIDR3D at 120 mA.

Conclusion

For chest CT, AIDR3D provides better image quality and can reduce radiation exposure by 50%.  相似文献   

11.

Objectives

To compare the image quality and diagnostic performance of two non-contrast enhanced MR angiography (NCE-MRA) techniques using flow-sensitive dephasing (FSD) prepared steady-state free precession (SSFP) and quiescent-interval single-shot (QISS) for the calf arteries in patients with diabetes.

Materials and Methods

Twenty six patients underwent the two NCE-MRA techniques followed by contrast-enhanced MRA (CE-MRA) of lower extremity on a 1.5T MR system. Image quality scores, arterial stenosis scores, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel sharpness, and diagnostic accuracy for detecting more than 50% arterial stenosis were evaluated and statistically compared using CE-MRA as the reference standard.

Results

All examinations were performed successfully. Of the total 153 calf arterial segments obtained in the 26 patients, FSD and QISS showed no significant difference in the number of diagnostic arterial segments (151 [98%] vs. 147 [96%], respectively, P>0.05). The image quality of FSD was higher than that of QISS in the peroneal artery and posterior tibial artery (P<0.05), but no significant difference in the anterior tibial artery (P>0.05). SNR and CNR of FSD were higher than those of QISS (P<0.01), while FSD showed comparable vessel sharpness compared with QISS (P>0.05). The time efficiency of SNR and CNR between FSD and QISS showed no significant difference when taking into account the times for FSD-related scout scans. There was no difference in sensitivity (95% vs. 93%, P>0.05) and negative predictive value (98% vs. 97%, P>0.05) between FSD and QISS for detecting stenosis greater than 50%. However, FSD showed higher specificities (99% vs. 92%, P<0.05) and diagnostic accuracy (98% vs. 92%, P<0.05) compared to QISS.

Conclusion

Both FSD and QISS had similar high sensitivity and negative predictive value for detecting calf arteries with over 50% stenosis, but FSD showed slightly higher diagnostic specificity and better depiction of arterial lesions due to its isotropic submillimeter spatial resolution. QISS, being an easier to use and less time-consuming technique, could be a method of choice for rapid screening of arterial disease of the lower extremity.  相似文献   

12.

Aim

To investigate the potential of reducing the radiation dose in prospectively electrocardiogram-triggered coronary computed tomography angiography (CCTA) while maintaining diagnostic image quality using an iterative reconstruction technique (IRT).

Methods and Materials

Prospectively-gated CCTA were first performed on a phantom using 256-slice multi-detector CT scanner at 120 kVp, with the tube output gradually reduced from 210 mAs (Group A) to 125, 105, 84, and 63 mAs (Group B–E). All scans were reconstructed using filtered back projection (FBP) algorithm and five IRT levels (L2-6), image quality (IQ) assessment was performed. Based on the IQ assessment, Group D(120 kVp, 84 mAs) reconstructed with L5 was found to provide IQ comparable to that of Group A with FBP. In the patient study, 21 patients underwent CCTA using 120 kV, 210 mAs with FBP reconstruction (Group 1) followed by 36 patients scanned with 120 kV, 84 mAs with IRT L5 (Group 2). Subjective and objective IQ and effective radiation dose were compared between two groups.

Results

In the phantom scans, there were no significant differences in image noise, contrast-to-noise ratio (CNR) and modulation transfer function (MTF) curves between Group A and the 84 mAs, 63 mAs groups (Groups D and E). Group D (120 kV, 84 mAs and L5) provided an optimum balance, producing equivalent image quality to Group A, at the lowest possible radiation dose. In the patient study, there were no significant difference in image noise, signal-to-noise ratio (SNR) and CNR between Group 1 and Group 2 (p = 0.71, 0.31, 0.5, respectively). The effective radiation dose in Group 2 was 1.21±0.14 mSv compared to 3.20±0.58 mSv (Group 1), reflecting dose savings of 62.5% (p<0.05).

Conclusion

iterative reconstruction technique used in prospectively ECG-triggered 256-slice coronary CTA can provide radiation dose reductions of up to 62.5% with acceptable image quality.  相似文献   

13.

Background

Sterile protection in >90% of volunteers against homologous Plasmodium falciparum infection has been achieved only using the controlled human malaria infection (CHMI) model. This efficient model involves whole parasite immunizations under chloroquine prophylaxis (CPS-immunization), requiring only 30–45 mosquitoes bites infected with P. falciparum-sporozoites. Given the large diversity of P. falciparum parasites, it is essential to assess protection against heterologous parasite strains.

Methods

In an open-label follow-up study, 16 volunteers previously CPS-immunized and challenged with P. falciparum NF54 (West-Africa) in a dose de-escalation and challenge trial were re-challenged with clone NF135.C10 (Cambodia) at 14 months after the last immunization (NCT01660854).

Results

Two out of thirteen NF54 protected volunteers previously fully protected against NF54 were also fully protected against NF135.C10, while 11/13 showed a delayed patency (median prepatent period of 10.5 days (range 9.0–15.5) versus 8.5 days in 5 malaria-naïve controls (p = 0.0005). Analysis of patency by qPCR indicated a 91 to >99% estimated reduction of liver parasite load in 7/11 partially protected subjects. Three volunteers previously not protected against NF54, were also not protected against NF135.C10.

Conclusion

This study shows that CPS-immunization can induce heterologous protection for a period of more than one year, which is a further impetus for clinical development of whole parasite vaccines.

Trial Registration

Clinicaltrials.gov NCT01660854  相似文献   

14.

Background

Pulmonary rehabilitation programs only modestly enhance daily physical activity levels in patients with chronic obstructive pulmonary disease (COPD). This randomised controlled trial investigates the additional effect of an individual activity counselling program during pulmonary rehabilitation on physical activity levels in patients with moderate to very severe COPD.

Methods

Eighty patients (66±7 years, 81% male, forced expiratory volume in 1 second 45±16% of predicted) referred for a six‐month multidisciplinary pulmonary rehabilitation program were randomised. The intervention group was offered an additional eight-session activity counselling program. The primary outcomes were daily walking time and time spent in at least moderate intense activities.

Results

Baseline daily walking time was similar in the intervention and control group (median 33 [interquartile range 16–47] vs 29 [17–44]) whereas daily time spent in at least moderate intensity was somewhat higher in the intervention group (17[4–50] vs 12[2–26] min). No significant intervention*time interaction effects were observed in daily physical activity levels. In the whole group, daily walking time and time spent in at least moderate intense activities did not significantly change over time.

Conclusions

The present study identified no additional effect of eight individual activity counselling sessions during pulmonary rehabilitation to enhance physical activity levels in patients with COPD.

Trial Registration

clinicaltrials.gov NCT00948623  相似文献   

15.

Background and Purpose

In patients with myocardial infarction, ticagrelor reduces cardiovascular and sepsis-related mortality, and can cause dyspnea. It is suggested that this is caused by adenosine receptor stimulation, because in preclinical studies, ticagrelor blocks the nucleoside transporter and increases cellular ATP release. We now investigated the effects of ticagrelor on the adenosine system in humans in vivo.

Experimental Approach

In a double-blinded, placebo-controlled cross-over trial in 14 healthy subjects, we have tested whether ticagrelor (180 mg) affects adenosine- and dipyridamole-induced forearm vasodilation, as surrogates of nucleoside uptake inhibition and adenosine formation, respectively. Also, ex vivo uptake of adenosine and uridine in isolated red blood cells was measured. Primary endpoint was adenosine-induced vasodilation.

Key Results

Ticagrelor did not affect adenosine- or dipyridamole-induced forearm vasodilation. Also, ex vivo uptake of adenosine and uridine in isolated red blood cells was not affected by ticagrelor. In vitro, ticagrelor dose-dependently inhibited nucleoside uptake, but only at supra-physiological concentrations.

Conclusion and Implications

In conclusion, at relevant plasma concentration, ticagrelor does not affect adenosine transport, nor adenosine formation in healthy subjects. Therefore, it is unlikely that this mechanism is a relevant pleiotropic effect of ticagrelor.

Trial Registration

ClinicalTrials.gov NCT01996735  相似文献   

16.

Objectives

To investigate the reliability of CT-angiography of the lower extremities (run-off CTA) to derive a treatment decision in patients with acute and chronic peripheral artery disease (PAD).

Materials and Methods

314 patients referred for run-off CTA were includ-ed in this retrospective study. First, diagnostic confidence of run-off CTA to derive a treat-ment decision was assessed in an interdisciplinary vascular conference using a 2 point scale (sufficient or not sufficient diagnostic confidence) and compared with the image quality eval-uated by two readers in consensus in four different levels (abdominopelvic, thigh, calf, foot arteries). Second, reliability of treatment decision was verified in all patients undergoing re-vascularization therapy.

Results

Diagnostic confidence of run-off CTA to derive a treatment deci-sion was sufficient in all patients with acute and in 97% of patients (215/221) with chronic PAD, whereas the rate of run-off CTA with non-diagnostic image quality was considerably higher in the calf and foot level (acute vs. chronic; calf: 28% vs.17%; foot: 52% vs. 20%). Reliability of treatment decision was superior for patients with chronic (123/133 = 92%) than for patients with acute PAD (64/78 = 82%, P = 0.02).

Conclusion

Run-off CTA is a reliable imaging modality for primary diag-nostic work-up of patients with acute and chronic PAD.  相似文献   

17.

Introduction

The impact on treatment outcomes of XpertMTB/RIF, a molecular-based test that provides rapid diagnosis of tuberculosis (TB) and rifampicin resistance with high accuracy, has not been reported despite its adoption in a few countries. We here report treatment outcomes in a step-wedged cluster randomized trial for patients diagnosed with XpertMTB/RIF compared to patients diagnosed with sputum smear examination in public health facilities in Brazil.

Methods

Treatment outcome data were added to the trial database of patients diagnosed from 4 February to 4 October 2012, and crosschecked with data from the national mortality and the drug-resistant TB registers. Treatment outcomes in the intervention (n=2232) and baseline (n=1856) arms were compared using a multilevel regression model.

Results

Unfavourable outcomes were frequent in both arms, mainly due to loss to follow-up (16%). Overall unfavourable outcomes were not reduced in the intervention arm (29.6% versus 31.7%, OR=0.93; 95%CI=0.79-1.08). However, the overall TB-attributed death rate was lower in the intervention arm (2.3% vs. 3.8%). Adjusted for HIV status, age group and city, the intervention resulted in a 35% decrease in TB-attributed deaths (OR=0.65, 95%CI=0.44-0.97).

Conclusions

The proportion of patients successfully treated did not increase with Xpert MTB/RIF implementation, with high loss to follow-up rates in both arms. We did observe a 35% reduction in TB-related mortality, which we hypothesize may be explained by less advanced disease among the smear-negative patients diagnosed by Xpert. In conclusion, XpertMTB/RIF introduction did not improve TB treatment outcomes in Brazil.

Trial Registration

clinicaltrials.gov NCT01363765  相似文献   

18.

Background

The mechanisms of drug-induced visions are poorly understood. Very few serotonergic hallucinogens have been studied in humans in decades, despite widespread use of these drugs and potential relevance of their mechanisms to hallucinations occurring in psychiatric and neurological disorders.

Methodology/Principal Findings

We investigated the mechanisms of hallucinogen-induced visions by measuring the visual and perceptual effects of the hallucinogenic serotonin 5-HT2AR receptor agonist and monoamine releaser, 3,4-methylenedioxyamphetamine (MDA), in a double-blind placebo-controlled study. We found that MDA increased self-report measures of mystical-type experience and other hallucinogen-like effects, including reported visual alterations. MDA produced a significant increase in closed-eye visions (CEVs), with considerable individual variation. Magnitude of CEVs after MDA was associated with lower performance on measures of contour integration and object recognition.

Conclusions/Significance

Drug-induced visions may have greater intensity in people with poor sensory or perceptual processing, suggesting common mechanisms with other hallucinatory syndromes. MDA is a potential tool to investigate mystical experiences and visual perception.

Trial Registration

Clinicaltrials.gov NCT00823407  相似文献   

19.

Objectives

To investigate the feasibility of high-pitch CT pulmonary angiography (CTPA) in 3rd generation dual-source CT (DSCT) in unselected patients.

Methods

Forty-seven patients with suspected pulmonary embolism underwent high-pitch CTPA on a 3rd generation dual-source CT scanner. CT dose index (CTDIvol) and dose length product (DLP) were obtained. Objective image quality was analyzed by calculating signal-to-noise-ratio (SNR) and contrast-to-noise ratio (CNR). Subjective image quality on the central, lobar, segmental and subsegmental level was rated by two experienced radiologists.

Results

Median CTDI was 8.1 mGy and median DLP was 274 mGy*cm. Median SNR was 32.9 in the central and 31.9 in the segmental pulmonary arteries. CNR was 29.2 in the central and 28.2 in the segmental pulmonary arteries. Median image quality was “excellent” in central and lobar arteries and “good” in subsegmental arteries according to both readers. Segmental arteries varied between “excellent” and “good”. Image quality was non-diagnostic in one case (2%), beginning in the lobar arteries. Thirteen patients (28%) showed minor motion artifacts.

Conclusions

In third-generation dual-source CT, high-pitch CTPA is feasible for unselected patients. It yields excellent image quality with minimal motion artifacts. However, compared to standard-pitch cohorts, no distinct decrease in radiation dose was observed.  相似文献   

20.

Background

Preventing or slowing the progression of prediabetes to diabetes is a major therapeutic issue.

Objectives

Our aim was to evaluate the effects of 4-month treatment with a dietary supplement containing cinnamon, chromium and carnosine in moderately obese or overweight pre-diabetic subjects, the primary outcome being change in fasting plasma glucose (FPG) level. Other parameters of plasma glucose homeostasis, lipid profile, adiposity and inflammatory markers were also assessed.

Methods

In a randomized, double-blind, placebo-controlled study, 62 subjects with a FPG level ranging from 5.55 to 7 mmol/L and a body mass index ≥25 kg/m2, unwilling to change their dietary and physical activity habits, were allocated to receive a 4-month treatment with either 1.2 g/day of the dietary supplement or placebo. Patients were followed up until 6 months post-randomization.

Results

Four-month treatment with the dietary supplement decreased FPG compared to placebo (-0.24±0.50 vs +0.12±0.59 mmol/L, respectively, p = 0.02), without detectable significant changes in HbA1c. Insulin sensitivity markers, plasma insulin, plasma lipids and inflammatory markers did not differ between the treatment groups. Although there were no significant differences in changes in body weight and energy or macronutrient intakes between the two groups, fat-free mass (%) increased with the dietary supplement compared to placebo (p = 0.02). Subjects with a higher FPG level and a milder inflammatory state at baseline benefited most from the dietary supplement.

Conclusions

Four-month treatment with a dietary supplement containing cinnamon, chromium and carnosine decreased FPG and increased fat-free mass in overweight or obese pre-diabetic subjects. These beneficial effects might open up new avenues in the prevention of diabetes.

Trial Registration

ClinicalTrials.gov NCT01530685  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号