首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A liquid chromatography-tandem mass spectrometric (LC-MS-MS) method with a rapid and simple sample preparation was developed and validated for the determination of Tirofiban in biological fluids. Tirofiban in serum samples was extracted and cleaned up by using an automated solid phase extraction method. An external calibration was used. The mass spectrometer was operated in the multiple reaction monitoring mode (MRM). A good linear response over the range of 2-200ng/ml was demonstrated. The accuracy for Tirofiban ranged from 94.8 to 110.8% within-day and from 103.0 to 104.7% between-day. The lower limit of quantification was 2ng/ml. This method is suitable for pharmacokinetic studies.  相似文献   

2.
In the present paper we report the LC-MS/MS determination of residues of 12 anabolic steroids in bovine serum, as an expansion of our work protocols for steroids determination in biological matrices. Steroids analyzed included α-zearalanol, β-zearalanol, α-trenbolone, β-trenbolone, methyltestosterone, α-estradiol, β-estradiol, ethynylestradiol, α-boldenone, β-boldenone, α-nortestosterone and β-nortestosterone. Following protein precipitation, serum samples were cleaned up by solid-phase extraction using Oasis HLB and Amino cartridges. Atmospheric pressure chemical ionization (APCI) in both positive and negative ionization modes was used and mass spectrometry detection was carried out in multiple reaction monitoring mode following two or (in most cases) three product ions per precursor ion. The method was validated in accordance with the Commission Decision 2002/657/EC. The decision limit (CCα) values obtained, ranged from 0.01 to 0.07 ng/ml and the detection capability (CCβ) values obtained ranged from 0.02 to 0.12 ng/ml. The recoveries ranged from 70.2% to 118.2%. The developed method is suitable for routine and confirmatory purposes such as control of illegal use in livestock production.  相似文献   

3.
A sensitive method was developed for quantitation of the cytotoxic antibiotic l-alanosine in human plasma. Alanosine was extracted from plasma by anion-exchange solid phase extraction, derivatized with dansyl chloride and analyzed by liquid chromatography-tandem mass spectrometry using atmospheric pressure chemical ionization in negative mode. Dansylation led to 50-fold improvement of method sensitivity over non-dansylated alanosine with a resulting 20 ng/ml limit of alanosine quantitation in plasma being achieved. The method was validated and applied for clinical studies of alanosine administered to cancer patients.  相似文献   

4.
A liquid chromatography-electrospray tandem mass spectrometry method was developed and validated to quantitate solifenacin in human plasma. The assay was based on protein precipitation with methanol and liquid chromatography performed on a pentafluorophenylpropylsilica column (50×4mm, 3μm particles), the mobile phase consisted of methanol - 100mM ammonium acetate containing 1% of formic acid (90:10, v/v). Quantification was through positive-ion mode and selected reaction monitoring at m/z 363→193 and 368→198 for solifenacin and the internal standard solifenacin-D(5), respectively. The lower limit of quantitation was 0.47ng/ml using 0.25ml of plasma and linearity was demonstrated up to 42ng/ml. Intra-assay and inter-assay precision expressed by relative standard deviation was less than 11% and inaccuracy did not exceed 11% at all levels. The assay was applied to the analysis of samples from a pharmacokinetic study.  相似文献   

5.
A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric (LC/MS/MS) method for the determination of tiropramide in human plasma was developed. Tiropramide and internal standard, cisapride were extracted from human plasma by liquid-liquid extraction and analyzed on a Luna C8 column with the mobile phase of acetonitrile-ammonium formate (10mM, pH 4.5) (50:50, v/v). The analytes was detected using an electrospray ionization tandem mass spectrometry in the multiple-reaction-monitoring mode. The standard curve was linear (r=0.998) over the concentration range of 2.0-200 ng/ml. The intra- and inter-assay coefficients of variation ranged from 2.8 to 7.8 and 6.7 to 8.9%, respectively. The recoveries of tiropramide ranged from 50.2 to 53.1%, with that of cisapride (internal standard) being 60.9+/-5.3%. The lower limit of quantification for tiropramide was 2.0 ng/ml using 100 microl plasma sample. This method was applied to the pharmacokinetic study of tiropramide in human.  相似文献   

6.
A rapid, selective and sensitive method for the determination of the angiotensin II receptor antagonist, telmisartan, in human plasma has been developed. Telmisartan and the internal standard, diphenhydramine, were extracted from plasma using diethyl ether-dichloromethane (60:40, v/v), and separated on a Zorbax extend C(18) column using methanol-10mM ammonium acetate (85:15, v/v) adjusted to pH 4.5 after mixing with formic acid as mobile phase. Detection was carried out by multiple reaction monitoring on a Q-trap LC-MS/MS system with an ESI interface. The assay was linear over the range 0.5-600.0 ng/ml with a limit of quantitation of 0.5 ng/ml and a limit of detection of 0.05 ng/ml. Intra- and inter-day precision were <6.7% and <8.1%, respectively, and the accuracy was in the range 88.9-111.0%. The assay was applied to a pharmacokinetic study of telmisartan given as a single oral dose (80 mg) to healthy volunteers.  相似文献   

7.
A sensitive and specific high-performance liquid chromatography-tandem mass spectrometric (LC-MS/MS) assay for dioscin in rat plasma was developed. Ginsenoside Rh2 was employed as an internal standard. Dioscin is a naturally occurring saponin present in many traditional Chinese medicinal plants. Dioscin was determined after the acetonitrile-mediated plasma protein precipitation. The mobile phase consisted of acetonitrile:10 mmol/l aqueous ammonium acetate (95:5, v:v), which was pumped at 0.8 ml/min. The analytical column (100 mm x 4.6 mm i.d.) was packed with Hypersil ODS material (5 microm). The standard curve was linear from 1 to 100 ng/ml. The assay was specific, accurate (percentage deviations from nominal concentrations were <10%), precise and reproducible (within- and between-day coefficients of variation <10%). Dioscin in rat plasma was stable over three freeze-thaw cycles and at ambient temperatures for 24 h. The utility of the assay was demonstrated by determining dioscin plasma concentrations in five rats for 120 h following a single oral gavage dose of 90 mg/kg.  相似文献   

8.
Protodioscin (3-O-[alpha-L-rhamnopyranosyl-(1-->2)-{alpha-L-rhamnopyranosyl-(1-->4)}-beta-D-glucopyranosyl]-26-O-[beta-D-glucopyranosyl]-(25 R)-furost-5-ene-3 beta,26-diol) is a naturally occurring saponin present in many oriental vegetables and traditional medicinal plants, which has been associated with potent bioactivity. However, there is no specific and sensitive assay for quantitative determination of protodioscin in biological samples. We have established a rapid, sensitive and selective LC-ESI-MS/MS method to measure protodioscin in rat plasma and investigated the pharmacokinetics of protodioscin after intravenous administrations. Plasma samples were prepared after plasma protein precipitation, and a aliquot of the supernatant was injected directly onto an analytical column with a mobile phase consisted of acetonitrile-water-formic acid (80:20:0.1, v/v/v). Analytes were detected with a LC-ESI-MS/MS system in positive selected multiple reaction-monitoring mode. The lower limit of quantification (LLOQ) was 20.0 ng/mL and a linear range of 20-125,000 ng/mL. The intra- and inter-day relative standard deviation (R.S.D.) across three validation runs over the entire concentration range was <8.0%. Accuracy determined at three concentrations (50, 5000 and 50,000 ng/mL for protodioscin) ranged from 0.2 to 1.8% as terms of relative error (R.E.). Each plasma sample was chromatographed within 3.5 min. This LC-ESI-MS/MS method allows accurate, high-throughput analysis of protodioscin in small amounts of plasma.  相似文献   

9.
A liquid chromatographic-tandem mass spectrometric (LC-MS-MS) assay was developed and validated to quantitatively determine olanzapine (OLZ) concentrations in human blood. Liquid-liquid extraction, using n-butanol:cyclohexane (3:47, v/v), was used to isolate OLZ and its internal standard, LY170158, from the biological matrix. Chromatographic resolution of OLZ from endogenous interferences and known metabolites was accomplished with a MetaChem Monochrom HPLC column (4.6 x 150 mm, d(p) 5 microm). Detection occurred using a Perkin-Elmer Sciex API III Plus triple quadrupole mass spectrometer using positive ion APCI and multiple reaction monitoring (MRM). The linear dynamic range was from 5 to 500 ng ml(-1) based on a 0.25-ml aliquot of human blood. The inter-day precision (%RSD) and accuracy (%RE) ranged from 3.65 to 10.64 and from -2.14 to 3.07, respectively. Modifications to an existing assay for the determination of OLZ in human plasma were necessary. A different structural analog was used as the internal standard due to instability observed for the original analog when using human blood as the matrix. A second modification was the addition of the anti-oxidant sodium ascorbate to inhibit degradation of OLZ in human blood, as has been noted by other investigators. Upon fortification of human blood with sodium ascorbate (final concentration, 0.33 mM), OLZ was found to be stable for at least 1 week at -70 degrees C as well as through two freeze-thaw cycles. This assay, which will be used to investigate the distribution of OLZ in human blood, grants insight into the proper sample handling conditions needed to perform valid determinations of OLZ in human blood.  相似文献   

10.
A rapid, simple and sensitive method was developed for the determination of para-aminohippuric acid (PAH) in rat plasma using liquid chromatography tandem mass spectrometry (LC-MS-MS). Acetaminophen was used as the internal standard. Chromatographic separation was performed using a Symmetry C18 column and the mobile phase was composed of A: 2 mM ammonium formate and 0.1% formic acid in water and B: 2 mM ammonium formate and 0.1% formic acid in acetonitrile (ACN) (A:B, 30:70, v/v). Detection was performed on a triple–quadrupole tandem mass spectrometer using positive ion mode electrospray ionization (ESI) in the multiple reaction monitoring (MRM) mode. The MS/MS ion transitions monitored were m/z 195.2 → 120.2 and 152.1 → 110.1 for PAH and acetaminophen, respectively. Good linearity is observed over the concentration range of 0.1–500 μg/ml. The method was proved to be accurate and reliable and was applied to a pharmacokinetic study in rat.  相似文献   

11.
This paper describes a simple, robust and cost-effective assay for the determination of ecabet in human plasma. After a simple step of protein precipitation using methanol, plasma samples were analyzed by reverse phase high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) with valsartan as the internal standard (I.S.). Ecabet and the I.S. valsartan were separated on a Venusil MP C18 analytical column using methanol-10mM ammonium acetate (75:25, v/v, pH 3.0) as mobile phase at a flow rate of 1.0 mL/min. Ecabet and I.S. were eluted at 0.91 and 0.92 min, respectively, ionized in negative mode, and then detected by multiple reaction monitoring (MRM) essay. The MRM transitions of m/z 379.1-->m/z 277.1 and m/z 434.3-->m/z 350.1 were used to quantify ecabet and I.S., respectively. The assay was linear over the concentration range of 10-6000 ng/mL and was successfully applied to a pharmacokinetic study in healthy volunteers.  相似文献   

12.
A simple, rapid and specific high-performance liquid chromatography coupled with tandem mass spectrometry (LC-MS-MS) has been developed and validated for the determination of ketoconazole in human plasma. The method used diethyl ether to extract the ketoconazole and the internal standard (I.S.) R51012 from alkalinized plasma sample. The LC separation was on a C(18) column (50 x 3 mm, 5 microm) using acetonitrile-water-formic acid (75:25:1, v/v/v) mobile phase. The retention times were approximately 1.8 min for both ketoconazole and the I.S. The MS-MS detection was by monitoring 531.2-->82.1 (m/z) for ketoconazole, and 733.5-->460.2 (m/z) for the I.S. The dynamic range was from 20.0 to 10000 ng/ml based on 0.1 ml plasma, with linear correlation coefficient of > or =0.9985. The run time was 2.5 min/injection. The recoveries of ketoconazole and the I.S. were 102 and 106%, respectively. The precision and accuracy of the control samples were with the relative standard deviations (RSDs) of < or =4.4% (n=6) and the relative errors (REs) from -0.6 to 1.4% for intra-day assay, and < or =8.6% RSD (n=18) and -1.4 to 0.9% RE for inter-day assay. The partial volume tests demonstrated good dilution integrity. Three freeze-thaw cycles, keeping plasma samples at ambient for 24 h, storing extracted samples at ambient for 24 h, and storing frozen plasma samples at approximately -20 degrees C for up to 2 months did not show substantial effects.  相似文献   

13.
Diesters of 1,2-benzenedicarboxylic acid are a family of industrial compounds called "phthalates." The physical and chemical properties of these diesters, and therefore their potential uses, depend on the structure of the dialkyl or alkyl/aryl side chain. The urinary concentrations of phthalate monoesters, which are metabolites, have been used as biomarkers of human exposure to specific phthalates. However, several phthalates, particularly those with side chains of eight or more carbon atoms, are complex mixtures of isomers. For these, the phthalate metabolites to be used as biomarkers of exposure have not been unequivocally identified. We developed a method for assessing total exposure to phthalates, including the isomeric mixtures of high molecular weight phthalates, by measuring the concentration of phthalic acid (PA) in human urine after acid hydrolysis of the phthalate metabolites to PA. The present method accurately assesses total exposure to phthalates without noticeable contamination from the ubiquitous phthalates in the environment, but it gives no information about the parent phthalate.  相似文献   

14.
In this paper, a new determination method for isometamidium residues in animal-derived foods was developed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Isometamidium residues in bovine tissues and milk were extracted with the mixed solution of acetonitrile and 0.25 mol/L of ammonium formate-methanol (v/v, 1:1), concentrated and degreased, and determined by LC-MS/MS with quantification by external standard method. The results showed that the peak area of chromatogram was linearly related to the concentration of isometamidium in the range of 1-100 μg/L, and the limits of detection (LOD) and quantification (LOQ) were 0.05 μg/kg and 5 μg/kg, respectively. The average recoveries of spiked samples were in the range of 73.8-93.9% with relative standard deviations ranged from 2.3% to 7.5%. This method is simple, accurate and suitable for the identification and quantification for isometamidium in animal-derived foods.  相似文献   

15.
A method for the analysis of six protease inhibitors and one metabolite has been developed and validated. Amprenavir, ritonavir, saquinavir, lopinavir, indinavir, nelfinavir, and an active metabolite of nelfinavir (M8) are quantitated using reversed-phase liquid chromatography coupled to tandem mass spectrometry, equipped with an electrospray ionization source (ESI-LC-MS-MS). The validation data presented here shows that the method allows the rugged analysis of these species from one aliquot. The evolution of complex drug interactions assessments and the clinical use of therapeutic drug monitoring for these antiretrovirals will be a potential immediate application of this method.  相似文献   

16.
Comprehensive quantitative analysis of lipid mediators using liquid chromatography-tandem mass spectrometry is an effective strategy in the elucidation of disease mechanisms; but technically, it has been and is still a great challenge to achieve reliable datasets that cover variety of lipid metabolites contained at trace levels in complex biological matrices. In this opinion article, we introduce our experiences in developing lipid mediator profiling systems, and deliver some comments on limitations of current methodology.  相似文献   

17.
The concentration of polyamines in red blood cells (RBCs) is considered to be an index of cell proliferation. This index has been demonstrated to be of clinical importance for the follow-up and treatment of some cancer patients. The concentration of polyamines in RBCs is usually determined by high-performance liquid chromatography (HPLC) with fluorescence detection. In the current work, we present a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of putrescine, spermidine, and spermine, the three major polyamines in RBCs. The polyamines were dansylated and analyzed by an LC gradient of 20-min duration on a C18 column on-line with a tandem mass spectrometer. An internal standard (1,8-diaminooctane) was used for quantification. This method exhibited excellent linearity for the three polyamines with regression coefficients higher than 0.99. The limits of detection for putrescine, spermidine, and spermine were 0.10, 0.75, and 0.50 pmol/ml, respectively. The intrarun precision values for putrescine, spermidine, and spermine all were better than 10%, and the interrun precision values were 13%, 9%, and 20%, respectively. The LC-MS/MS method is sufficiently simple and reliable enough to replace the currently used HPLC method with fluorescence detection in which putrescine is not always detectable.  相似文献   

18.
A sensitive and selective analytical method based on liquid chromatography-triple-quadrupole mass spectrometer has been developed to determine mildronate in human plasma and urine. The aim of this work was to find a valid method to study the pharmacokinetic profiles of mildronate in humans. Mildronate is a heart protection medicine, a carnitine's structural analogue, so levocarnitine was used as an internal standard for quantification. Under the electrospray ionization source positive ion mode, calibration curves with good linearities (r=0.9998 for plasma sample and r=0.9999 for urine sample) were obtained in the range of 1.0-20,000 ng ml(-1) for mildronate. The detection limit was 1 ng ml(-1). Recoveries were around 90% for the extraction from human plasma, and good precision and accuracy were achieved. This method is feasible for the evaluation of pharmacokinetic profiles of mildronate in humans, and to the best of our knowledge, this is the first report on LC-MS-MS analysis of mildronate in plasma and urine.  相似文献   

19.
A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of beraprost, a stable, orally active prostacyclin analogue with vasodilatory, antiplatelet and cytoprotective effects. The analyte and internal standard, indomethacin, were extracted by solid-phase extraction using OASIS HLB cartridge. The chromatographic separation was performed on a C18 column with a mobile of 0.1% formic acid-methanol (30:70, v/v). The highest daughter ion of deprotonated analyte was quantitated in negative ionization by multiple reactions monitoring with a mass spectrometer. The mass transitions m/z 397>269 and m/z 356>312 were used to measure beraprost and internal standard, respectively. The assay exhibited a linear range from 0.02 to 2 ng/mL for beraprost in human plasma. The lower limit of quantitation was 20 pg/mL with a relative standard deviation of less than 20%. The method was validated with respect to linearity, sensitivity, specificity, recovery, accuracy and precision. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic study.  相似文献   

20.
Fumonisins are water soluble mycotoxins produced by the fungus Fusarium verticillioides (formerly F. moniliforme). Fumonisin B(1) (FB(1)) is a diester of propane-1,2,3-tricarboxylic acid and 2-amino-12, 16-dimethyl-3,5,10,14,15-pentahydroxyeicosane, and is the most abundant of the naturally occurring fumonisins. Upon removal of the two tricarballylic acid side chains, the structure is referred to as hydrolyzed FB(1) (HFB(1)). FB(1) and HFB(1) are structurally similar to sphinganine, a sphingoid base. The fumonisins do not absorb UV light or fluoresce; therefore, derivatizing reagents are used for detection when separation is by high performance liquid chromatography (HPLC). The standard derivatizing reagent used for HPLC is ortho-phthalaldehyde (OPA) plus 2-mercaptoethanol (ME) reaction partner, however, the OPA-FB(1) derivative is not stable at room temperature. The objectives of this study were to: (1). determine the effect of temperature on the stability of the OPA-FB(1) derivative and (2). determine which structural characteristics of FB(1) contribute to the instability of the OPA-FB(1) derivative. The results indicate that OPA-FB(1), OPA-FB(3) and OPA-HFB(1) derivatives are unstable at 24 degrees C but that their stability improves significantly at 4 degrees C. The OPA-sphinganine derivative is stable for at least 24h at 24 degrees C. Thus, the instability of the OPA-FB(1) derivative may be attributed to its lack of a hydroxyl group at the carbon 1 position.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号