首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Nitrogen and carbon components in domestic modified wastewater were completely removed by simultaneous nitrification and denitrification using a membrane-aerated biofilm reactor where biofilm was fixed on a hollow-fiber membrane. To measure the spatial distribution of pH, ammonium and nitrate ions and to observe microbes inside the biofilm fixed on the membrane, microelectrodes and the fluorescence in situ hybridization (FISH) method were applied. Due to plug flow in the vertical direction (from the bottom to the top of the reactor), ammonium nitrogen was gradually removed and negligible nitrate nitrogen was detected throughout the reactor. FISH revealed that ammonia-oxidizing bacteria were mainly distributed inside the biofilm and other bacteria, which included denitrifying bacteria, were mainly distributed outside the biofilm and over the suspended sludge. In order to characterize bacterial activity in the vertical direction of the reactor, nitrification rates at lower, central and upper points were calculated using microelectrode data. The nitrification rate at the lower point was 7 and 125 times higher than those at the central and upper points, respectively. These results show that the removal of carbon and nitrogen compounds was accomplished efficiently by using various kinds of bacteria distributed vertically and horizontally in a single reactor.  相似文献   

2.
AIMS: To develop a laboratory-scale autotrophic membrane-immobilized biofilm reactor to remove nitrogen from drinking water. METHODS AND RESULTS: A polyvinyl alcohol (PVA) immobilized biofilm, attached to the surface of a silicone tube, was used as the basis of a bioreactor for simultaneous nitrification and denitrification of water. The bioreactor was aerated with air to supply oxygen for nitrification. Pure hydrogen was supplied to the silicone tube and diffused through the membrane wall to feed the biofilm for autotrophic denitrification. The bioreactor was effective for the simultaneous nitrification and denitrification of water after a short period of acclimation, while the biofilm exhibited good resistance to the inhibition of denitrification by dissolved oxygen; the denitrification rate decreased by only 8% as the dissolved oxygen increased from 2 mg l(-1) to saturation. CONCLUSIONS: By using PVA crosslinked with sodium nitrate to entrap nitrifying and denitrifying sludge on the surface of a silicone tube, a novel bioreactor for simultaneous nitrification and denitrification was developed. In addition to performing as an immobilizing agent to strengthen the biofilm, PVA protected the denitrifying microorganisms to reduce the inhibition by dissolved oxygen under aerobic condition. Therefore, nitrification and denitrification occurred simultaneously within the biofilm. Furthermore, the immobilization technique shortened the acclimation period of the bioreactor. SIGNIFICANCE AND IMPACT OF THE STUDY: The described space saving and simple to operate bioreactor for nitrogen removal performed autotrophic denitrification to solve the problem of residual carbon in heterotrophic denitrification, and thus is suitable for removing nitrogen from drinking water.  相似文献   

3.
Anaerobic treatment of wastewater from the pharmaceutical industry, which contained about 3.2 g/L of sulfate, was carried out in an Upflow Anaerobic Sludge Blanket (UASB) reactor. After a startup period of 120 days, a chemical oxygen demand (COD) removal efficiency of more than 90 % was obtained along with an organic loading rate (OLR) of 1.5 g COD/(L day). During the same period, the sulfate removal was about 90 %. However, the performance of the reactor was affected when the loading rate was increased to 2.09 g COD/(L day). It was found that the accumulation of sulfides, combined with a decrease in the pH, affected the reactor performance. In batch reactor studies with pharmaceutical wastewater it was observed that methane production began only after the initiation of nitrate consumption. The denitrification process can inhibit sulfate reduction at high nitrate concentrations, but compared to reactors without nitrate, the sulfate reduction process and sulfide formation were quickly initiated at low nitrate concentrations. The methanogenic activity was however affected by the presence of more than 2 g/L of sulfate.  相似文献   

4.
以纸为碳源去除地下水硝酸盐的研究   总被引:13,自引:0,他引:13  
研究了以纸为碳源和反应介质的生物反应器对水中硝酸盐的去除。结果表明,以纸为碳源的反应器启动快.反硝化反应受温度及水力停留时间影响大。25℃的反硝化速率是14℃的1.7倍。在室温25±1℃,进水硝酸盐氮浓度为45.2mg·L^-1、水力停留时间8.6h时,反应器对硝酸盐氮的去除率在99.6%以上,当水力停留时间为7.2h,氮去除率只有50%。反硝化反应受pH值和溶解氧的影响小,反应进行过程中,纸表面形成了生物膜,纸也被消耗了.采用反应器出水再经活性炭吸附的工艺流程处理高硝酸盐氮地下水,<33.9mg·L^-1的硝酸盐氮完全去除,没有出现NC2-N,最终出水水质DOC<11mg·L^-1。  相似文献   

5.
基于响应面法对一株好氧反硝化菌脱氮效能优化   总被引:2,自引:1,他引:1  
【目的】水体富营养化是当今我国水环境面临的重大水域环境问题,氮素超标排放是主要的引发因素之一。好氧反硝化菌构建同步硝化反硝化工艺比传统脱氮工艺优势更大。获得高效的好氧反硝化菌株并通过生长因子优化使脱氮效率达到最高。【方法】经过序批式生物反应器(Sequencing batch reactor,SBR)的定向驯化,筛选获得高效好氧反硝化菌株,采用响应面法优化好氧反硝化过程影响总氮去除效率的关键因子(碳氮、溶解氧、pH、温度)。【结果】从运行稳定的SBR反应器中定向筛选高效好氧反硝化菌株Pseudomonas T13,采用响应面法对碳氮比、pH和溶解氧关键因子综合优化获得在18 h内最高硝酸盐去除率95%,总氮去除率90%。该菌株的高效反硝化效果的适宜温度范围为25?30 °C;最适pH为中性偏碱;适宜的COD/NO3?-N为4:1以上;最佳溶解氧浓度在2.5 mg/L。【结论】从长期稳定运行的SBR反应器中筛选获得一株高效好氧反硝化菌Pseudomonas T13,硝酸盐还原酶比例占脱氮酶基因的30%以上,通过运行条件优化获得硝氮去除率达到90%以上,对强化废水脱氮工艺具有良好应用价值。  相似文献   

6.
A fluidized bed biofilm reactor using sand as the carrier particle was employed to study the effects of superficial velocity on the removal of nitrates as well as on the growth of the biofilm. Velocity was found to affect significantly both nitrate removal and biofilm growth. An analysis based on heterogenous catalysis was used to describe the denitrification process. There is good agreement between analysis and experimental measurements for startup and steady-state operating conditions.  相似文献   

7.
An acetic-acid-based synthetic wastewater of different organic concentrations was successfully treated at 35 degrees C in anaerobic downflow fixed-film reactors operated at high organic loading rates and short hydraulic retention times (HRTs). Substrate removal and methane production rates close to theoretical values of complete volumetric chemical oxygen demand (COD) removal and maximum methane conversion were obtained. A high concentration of biofilm biomass was retained in the reactor. Steady-state biofilm concentration increased with increased organic loading rate and decreased HRTs, reaching a maximum of 8.3 kg VFS/m(3) at a loading rate of 17 kg COD/m(3) day. Biofilm substrate utilization rates of up to 1.6 kg COD/kg VFS day were achieved. Soluble COD utilization rates at various COD concentrations can be described by half-order reaction kinetics.  相似文献   

8.
AIMS: A laboratory-scale autotrophic membrane-attached biofilm reactor was developed to remove nitrate from drinking water. METHODS AND RESULTS: Hydrogen and carbon dioxide flowed together into the lumem side of a gas-permeable silicone tube. The gases diffused through the membrane wall to feed Alcaligenes eutrophus that formed a biofilm on the surface of the silicone tube for autotrophic denitrification. Hydrogen provided the energy source, and carbon dioxide, besides serving as the carbon source, was employed to neutralize the alkalinity from denitrification. The optimal carbon dioxide concentration in the silicone tube was between 20% and 50%. CONCLUSION: This study has demonstrated that a gas-permeable silicone tube is a convenient and efficient method to feed A. eutrophus for autotrophic denitrification. Supplying a suitable amount of carbon dioxide together with hydrogen into the silicone tube solved the problem that alkalinity formation caused during denitrification. The pH of the bioreactor was maintained at about 7 to avoid nitrite accumulation, and then the nitrogen removal rate was increased. A high specific nitrogen removal rate (1.6-5.4 g Nm(2)d(-1-1) of surface area of silicone tube) was achieved. SIGNIFICANCE AND IMPACT OF THE STUDY: In addition to combining the advantages of the hydrogenotrophic denitrification process and a membrane feeding substrate bioreactor (MFSB), this bioreactor achieved a high nitrogen removal rate and is simple to operate. It therefore is highly promising in drinking-water treatment.  相似文献   

9.
Simultaneous nitrification and denitrification (SND) was realized by means of a novel air-lift internal loop biofilm reactor, in which aeration was set in middle of the reactor. During operation, the aeration was adjusted to get appropriate dissolve oxygen (DO) in bulk solution and let aerobic and anoxic zone coexist in one reactor. When aeration was at 0.6 and 0.2 L/min, corresponding to DO of 5.8 and 2.5 mg/L in bulk solution, ammonia nitrogen removal percentage reached about 80 and 90 %, but total nitrogen removal percentage was lower than 25 %. While the aeration was reduced to 0.1 L/min, aerobic and anoxic zones existed simultaneously in one reactor to get 75 % of ammonia nitrogen and 50 % of total nitrogen removal percentage. Biofilms were, respectively, taken from aerobic and anoxic zone to verify their function of nitrification and denitrification in two flasks, in which ammonia nitrogen was transferred into nitrate completely by aerobic biofilm, and nitrate was removed more than 80 % by anoxic biofilm. Microelectrode was used to measure the DO distribution inside biofilms in anoxic zone corresponding to different aerations. When aeration was at 0.6 and 0.2 L/min, DO inside biofilm was more than 1.5 mg/L, but the DO inside biofilm decreased to anoxic status with depth of biofilm increasing corresponding to aeration of 0.1 L/min. The experimental results indicated that SND could be realized because of simultaneous existence of aerobic and anoxic biofilms in one reactor.  相似文献   

10.
Nitrification and denitrification are important microbiological reactions of nitrogen. In this work, the kinetics of these reactions have been investigated based on a Monod-type expression involving two growth limiting substrates: ammonium nitrogen and dissolved oxygen for nitrification and nitrate nitrogen and dissolved organic carbon for denitrification. The kinetic constants and yield coefficients were evaluated for both these reactions. Past experimental work was used to determine the constants for the nitrification reaction. For the denitrification reaction, experiments were performed in a stirred tank reactor under conditions such that only one substrate was growth limiting. Steady-state values of the substrate concentrations in the reactor were determined at various dilution rates. These data were analyzed to obtain the kinetic and stoichiometric constants. From these constants it was concluded that in the range of nitrate nitrogen concentrations encountered in waste water, the denitrification reaction can be considered a first-order reaction. It was also found that three times as much organic carbon is required as nitrate nitrogen for complete nitrogen removal.  相似文献   

11.
Sulfur-utilizing autotrophic denitrification relies on an inorganic carbon source to reduce the nitrate by producing sulfuric acid as an end product and can be used for the treatment of wastewaters containing high levels of nitrates. In this study, sulfur-denitrifying bacteria were used in anoxic batch tests with sulfur as the electron donor and nitrate as the electron acceptor. Various medium components were tested under different conditions. Sulfur denitrification can drop the medium pH by producing acid, thus stopping the process half way. To control this mechanism, a 2:1 ratio of sulfur to oyster shell powder was used. Oyster shell powder addition to a sulfurdenitrifying reactor completely removed the nitrate. Using 50, 100, and 200 g of sulfur particles, reaction rate constants of 5.33, 6.29, and 7.96 mg(1/2)/l(1/2)·h were obtained, respectively; and using 200 g of sulfur particles showed the highest nitrate removal rates. For different sulfur particle sizes ranging from small (0.85-2.0 mm), medium (2.0-4.0 mm), and large (4.0-4.75 mm), reaction rate constants of 31.56, 10.88, and 6.23 mg(1/2)/l(1/2)·h were calculated. The fastest nitrate removal rate was observed for the smallest particle size. Addition of chemical oxygen demand (COD), methanol as the external carbon source, with the autotrophic denitrification in sufficiently alkaline conditions, created a balance between heterotrophic denitrification (which raises the pH) and sulfur-utilizing autotrophic denitrification, which lowers the pH.  相似文献   

12.
Granular sludge from an upflow anaerobic sludge blanket reactor treating synthetic waste water containing a mixture of volatile fatty acids and nitrate showed a removal efficiency of nearly 100% for both nitrogen and carbon. This activity was achieved by a combined process of denitrification and methanogenesis under conditions of surplus carbon. Under batch conditions the two processes proceeded clearly separated in time with first denitrification dominating and excluding methanogenesis. However, as soon as nitrate was depleted, methane production was initiated, showing that the inhibition of methanogenesis by nitrate was reversible. Of the volatile fatty acids supplied to the reactor, i.e. acetate, propionate, and butyrate, the denitrifying population clearly preferred butyrate and propionate even though acetate could also be metabolized. Consequently, growth of syntrophic volatile fatty acid degraders was suppressed by the denitrifiers in cases of low C:N ratios in the medium, leaving acetate as the major substrate for methanogenesis.Abbreviations UASB upflow anaerobic sludge blanket - COD chemical oxygen demand - VFA volatile fatty  相似文献   

13.
Fei Zhang  Zhen He 《Process Biochemistry》2012,47(12):2146-2151
This study presented a dual-cathode microbial fuel cell (MFC) that was designed to accomplish nitrification in its outer cathode and denitrification in the inner cathode. The MFC was continuously operated for more than 150 days and achieved organic removal of 85–99% in the anode, depending on the initial organic loading rates. More than 96% of the ammonium was removed, while the total nitrogen removal was between 66.7 and 89.6%, largely affected by the remaining nitrate in the effluent of the inner cathode. The coulombic efficiency suggested that the nitrate was primarily removed by bioelectrochemcial denitrification in the inner cathode, especially at the low nitrogen loading rates. However, a higher nitrogen loading rate encouraged nitrate migration through the anion exchange membrane, thereby being removed by conventional denitrification. The preliminary energy analysis suggested that the energy production in the dual-cathode MFC could potentially support its pumping system. To achieve an energy-neutral system, aeration must be omitted in the future design and passive oxygen supply should be considered with a proper design of the outer cathode. Those results demonstrated the feasibility of using a tubular dual-cathode MFC to remove both organics and nitrogen while producing electricity.  相似文献   

14.
A hydrogenotrophic denitrification system was evaluated in removing nitrate from synthetic aquaculture wastewater for recirculation purposes. Two membrane bioreactor (MBR) systems, namely, aeration–denitrification system (ADS) and denitrification–aeration system (DAS) were studied with 50 mg/L of influent concentrations for both organic matter and nitrate nitrogen. The DAS achieved better removal efficiency of 91.4% total nitrogen (T-N) and denitrification rate of 363.7 mg/L.day at a HRT of 3 h compared to ADS. Further, there was no nitrite accumulation in the DAS effluent. The nitrite accumulation in ADS effluent was lesser when CO2 was used as buffer rather than K2HPO4 and KH2PO4. Estimation of kinetic parameters of hydrogenotrophic bacteria indicated lesser sludge production compared to heterotrophic denitrification. In the DAS, membrane fouling was nonexistent in the aeration reactor that was used to produce the recirculating effluent. On the contrary, membrane fouling was observed in the denitrification reactor that supplied hydrogen to the mixed liquor. Thus, this study demonstrated DAS capability in maintaining the acceptable water quality appropriate for aquaculture, in which a closed recirculating system is typically used.  相似文献   

15.
Summary The effects of nitrate on phosphorus release and uptake in a sequencing batch reactor for biological phosphorus removal was investigated. The addition of nitrate decreased phosphorus release in the anaerobic stage. The synthesis of poly(hydroxyalkanoates) was decreased with the presence of nitrate, possibly due to the competitive utilization of the carbon source by PHA synthesis and denitrification of nitrate. Instead of oxygen, nitrate could be used as an electron acceptor for phosphorus removal. However, the simultaneous addition of nitrate and acetate greatly reduced the phosphorus removal rate. Phosphate and nitrate could be removed simultaneously with nitrate as the electron acceptor, and the continuous and steady feeding of nitrate was beneficial to phosphate removal.  相似文献   

16.
Membrane process for biological treatment of contaminated gas streams   总被引:5,自引:0,他引:5  
A hollow fiber membrane bioreactor was investigated for control of air emissions of biodegradable volatile organic compounds (VOCs). In the membrane bioreactor, gases containing VOCs pass through the lumen of microporous hydrophobic hollow fiber membranes. Soluble compounds diffuse through the membrane pores and partition into a VOC degrading biofilm. The hollow fiber membranes serve as a support for the microbial population and provide a large surface area for VOC and oxygen mass transfer. Experiments were performed to investigate the effects of toluene loading rate, gas residence time, and liquid phase turbulence on toluene removal in a laboratory-scale membrane bioreactor. Initial acclimation of the microbial culture to toluene occurred over a period of nine days, after which a 70% removal efficiency was achieved at an inlet toluene concentration of 200 ppm and a gas residence time of 1.8 s (elimination capacity of 20 g m-3 min-1). At higher toluene loading rates, a maximum elimination capacity of 42 g m-3 min-1 was observed. In the absence of a biofilm (abiotic operation), mass transfer rates were found to increase with increasing liquid recirculation rates. Abiotic mass transfer coefficients could be estimated using a correlation of dimensionless parameters developed for heat transfer. Liquid phase recirculation rate had no effect on toluene removal when the biofilm was present, however. Three models of the reactor were created: a numeric model, a first-order flat sheet model, and a zero-order flat sheet model. Only the numeric model fit the data well, although removal predicted as a function of gas residence time disagreed slightly with that observed. A modification in the model to account for membrane phase resistance resulted in an underprediction of removal. Sensitivity analysis of the numeric model indicated that removal was a strong function of the liquid phase biomass density and biofilm diffusion coefficient, with diffusion rates below 10(-9) m2 s-1 resulting in decreased removal rates.  相似文献   

17.
An autotrophic denitrification process using reduced sulfur compounds (thiosulfate and sulfide) as electron donor in an activated sludge system is proposed as an efficient and cost effective alternative to conventional heterotrophic denitrification for inorganic (or with low C/N ratio) wastewaters and for simultaneous removal of sulfide or thiosulfate and nitrate. A suspended culture of sulfur-utilizing denitrifying bacteria was fast and efficiently established by bio-augmentation of activated sludge with Thiobacillus denitrificans. The stoichiometry of the process and the key factors, i.e. N/S ratio, that enable combined sulfide and nitrogen removal, were determined. An optimum N/S ratio of 1 (100% nitrate removal without nitrite formation and low thiosulfate concentrations in the effluent) has been obtained during reactor operation with thiosulfate at a nitrate loading rate (NLR) of 17.18 mmol N L(-1) d(-1). Complete nitrate and sulfide removal was achieved during reactor operation with sulfide at a NLR of 7.96 mmol N L(-1) d(-1) and at N/S ratio between 0.8 and 0.9, with oxidation of sulfide to sulfate. Complete nitrate removal while working at nitrate limiting conditions could be achieved by sulfide oxidation with low amounts of oxygen present in the influent, which kept the sulfide concentration below inhibitory levels.  相似文献   

18.
Wan D  Liu H  Liu R  Qu J 《Bioresource technology》2011,102(23):10803-10809
A novel combined system established for nitrate removal from aqueous solution consisted of two parts: sulfur autotrophic denitrification and bio-electrochemical denitrification based on proton-exchange membrane electrodialysis (PEMED). The system was operated at various hydraulic retention times (HRT) and current intensities. Its optimum operation condition was also determined. The combined process had pH adjustment thus generating less nitrite than PEMED process. The denitrification rate of sulfur autotrophic part was dependent on HRT, while shorter HRT could reduce the sulfate generated by the sulfur autotrophic process. The denitrification rate of PEMED process depended on the applied current. For 32 ± 1 mg-N/L nitrate in influent, the optimum operation parameters of combined process were: HRT 2 h; applied current 350 mA. The combined reactor could achieve 95.8% nitrate removal without nitrite accumulation, the pH of effluent kept neutral and the sulfate of effluent was 202.1 mg/L, lower than the drinking water standard in China.  相似文献   

19.
The Catskill Mountains of southeastern New York State have among thehighest rates of atmospheric nitrogen deposition in the United States. Somestreams draining Catskill catchments have shown dramatic increases in nitrateconcentrations while others have maintained low nitrate concentrations. Streamsin which exchange occurs between surface and subsurface (i.e. hyporheic) watersare thought to be conducive to nitrate removal via microbial assimilationand/ordenitrification. Hyporheic exchange was documented in the Neversink River inthesouthern Catskill Mountains, but dissolved organic carbon (DOC) and nitrate(NO3 ) losses along hyporheic flowpaths werenegligible. In this study, Neversink River water was amended with natural,bioavailable dissolved organic carbon (BDOC) (leaf leachate) in a series ofexperimental mesocosms that simulated hyporheic flowpaths. DOC and N dynamicswere examined before and throughout a three week BDOC amendment. In addition,bacterial production, dissolved oxygen demand, denitrification, and sixextracellular enzyme activities were measured to arrive at a mechanisticunderstanding of potential DOC and NO3 removalalong hyporheic flowpaths. There were marked declines in DOC and completeremoval of nitrate in the BDOC amended mesocosms. Independent approaches wereused to partition NO3 loss into two fractions:denitrification and assimilation. Microbial assimilation appears to be thepredominant process explaining N loss. These results suggest that variabilityinBDOC may contribute to temporal differences in NO3 export from streams in the Catskill Mountains.  相似文献   

20.
A sequencing batch membrane biofilm reactor (SBMBfR) was developed for simultaneous carbon, nitrogen, and phosphorus removal from wastewater. This reactor was composed of two functional parts: (1) a gas-permeable membrane on which a nitrifying biofilm formed and (2) a bulk solution in which bacteria, mainly denitrifying polyphosphate-accumulating organisms (DNPAOs), were suspended. The reactor was operated sequentially under anaerobic condition and then under membrane aeration condition in one cycle. During the anaerobic period, organic carbon was consumed by DNPAOs; this was accompanied by phosphate release. During the subsequent membrane aeration period, nitrifying bacteria utilized oxygen supplied directly to them from the inside of the membrane. Consequently, the nitrite and nitrate products diffused into the bulk solution, where they were used by DNPAOs as electron acceptors for phosphate uptake. In a long-term sequencing batch operation, the mean removal efficiencies of total organic carbon (TOC), total nitrogen (T-N), and total phosphorus (T-P) under steady-state condition were 99%, 96%, and 90%, respectively. In addition, fluorescence in situ hybridization (FISH) clearly demonstrated the difference in bacterial community structure between the membrane biofilm and the suspended sludge: ammonia-oxidizing bacteria belonging to the Nitrosomonas group were dominant in the region adjacent to the membrane throughout the operation, and the occupation ratio of the well-known polyphosphate-accumulating organism (PAO) Candidatus "Accumulibacter phosphates" in the suspended sludge gradually increased to a maximum of 37%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号