The glucose sensor was constructed by immobilizing glucose oxidase (GOD) with glutaraldehyde solution onto the sensitive area of the transparent oxygen electrode. The oxygen electrode was fabricated by sealing KCl electrolyte solution including the Indium-Tin Oxide (ITO)-electrode with both metal-weldable film and gas-permeable membrane coated with Ag/AgCl electrode. The sensor behavior was evaluated using standard glucose solutions in a batch measurement system with a computer-controlled potentiostat at a reduction potential of -900 mV. The sensor device has flexible structure and good optical transparency (less than 0.6 abs) at the visible wavelength from 400 to 700 nm. The sensor was possible to be used for measuring glucose from 0.06 to 1.24 mmol/l (correlation coefficient: 0.999), including the reported concentration of tear glucose in normal (0.14 mmol/l), with good reproducibility.  相似文献   

2.
A novel amperometric glucose sensor was constructed by immobilizing glucose oxidase (GOD) in a titania sol-gel film, which was prepared with a vapor deposition method. The sol-gel film was uniform, porous and showed a very low mass transport barrier and a regular dense distribution of GOD. Titania sol-gel matrix retained the native structure and activity of entrapped enzyme and prevented the cracking of conventional sol-gel glasses and the leaking of enzyme out of the film. With ferrocenium as a mediator the glucose sensor exhibited a fast response, a wide linear range from 0.07 to 15 mM. It showed a good accuracy and high sensitivity as 7.2 microA cm(-2) mM(-1). The general interferences coexisted in blood except ascorbic acid did not affect glucose determination, and coating Nafion film on the sol-gel film could eliminate the interference from ascorbic acid. The serum glucose determination results obtained with a flow injection analysis (FIA) system showed an acceptable accuracy, a good reproducibility and stability and indicated the sensor could be used in FIA determination of glucose. The vapor deposition method could fabricate glucose sensor in batches with a very small amount of enzyme.  相似文献   

3.
To understand the secretory mechanisms and physiological role of insulin in the tear film, the present study examined 1) the time course of insulin secretion in the tear film under glucose intravenous stimulation, 2) the glucose- and carbachol-induced insulin secretion from isolated lacrimal gland (LG), 3) the effect of insulin on glucose consumption by the cornea, and 4) the expression of insulin, pancreatic duodenal homeobox-1 (PDX-1), and glucose transport proteins (GLUTs) in LG tissue. The insulin level in the tear film of 8-wk-old male Wistar rats increased from 0.6 +/- 0.45 to 3.7 +/- 1.3 ng/ml in the initial minutes after glucose stimulation. In vitro assays demonstrated that higher glucose concentrations from 2.8 to 16.7 mM, 200 microM carbachol, or 40 mM KCl significantly increased insulin secretion from lacrimal glands compared with controls, but did not detect C-peptide as measured by RIA. Glucose consumption by corneal tissue, evaluated by radiolabeled D-[U-14C]glucose uptake, was 24.07 +/- 0.61 and was enhanced to 31.63 +/- 3.15 nmol x cornea(-1) x 2 h(-1) in the presence of 6 nM insulin (P = 0.033) and to 37.5 +/- 3.7 nmol x cornea(-1) x 2 h(-1) in the presence of 11.2 mM glucose (P = 0.015). Insulin and PDX-1 mRNA was detected in LG. Insulin was located in the apical areas of acinar cells by immunoperoxidase and the expression of GLUT-1, but not PDX-1, was confirmed by Western blot. These findings suggest that insulin secretion in the tear film is influenced by local stimuli such as nutrient and neural inputs and that this hormone plays a metabolic role in ocular surface tissues. These data also indicate that under normal conditions the insulin secreted by LG is stored, but it is not clear that is locally produced in the LG.  相似文献   

4.
The present communication demonstrates a relatively green preparative route toward Au nanoplates in aqueous solution at room temperature with the use of tannic acid (TA), which is an environmentally friendly, soluble polyphenol, as a reducing agent. Such Au nanoplates exhibit notable catalytic performance toward the oxidation and reduction of H(2)O(2). A glucose biosensor was further fabricated by immobilizing glucose oxidase (GOD) into chitosan-Au nanoplate composites film on the surface of glassy carbon electrode (GCE). This sensor exhibits good response to glucose, and the linear response range is estimated to be from 2 to 20 mM (R=0.999) at 0.65 V and from 2 to 10 mM (R=0.993) at -0.2 V, respectively. The sensitivity of the sensor determined from the slopes is 49.5 μA mM(-1)cm(-2) at 0.65 V.  相似文献   

5.
An amperometric glucose biosensor with glucose oxidase (GOx) immobilized into palladium hexacyanoferrate (PdHCF) hydrogel has been prepared and evaluated. The sensor was based on a two-layer configuration with biocatalytic and electrocatalytic layers separately deposited onto the electrode. To reduce the overpotential for reduction of hydrogen peroxide liberated in the enzyme catalyzed oxidation of glucose, an inner thin layer of nickel hexacyanoferrate (NiHCF) electrodeposited onto the surface of graphite electrode was used as an electrocatalyst. As an outer layer, the hydrogel of palladium hexacyanoferrate with entrapped glucose oxidase was used. Under optimal operating conditions (pH 5.0 and E = -0.075 V versus calomel (3.0 M KCl) reference electrode), sensor showed high sensitivity to glucose (0.3-1.0 microA/mM) and a response time of less than 30s. The linear response to glucose was obtained in the concentration range between 0.05 and 1.0 mM in batch analysis mode and 0-7.0 mM in FIA. During the 32 days testing period, no significant decrease in the sensor sensitivity was observed. The sensor was applied for the determination of glucose concentration in fruit juice and yoghurt drink, and the results obtained showed good correlation with results obtained by reference spectrophotometric enzyme method.  相似文献   

6.
Erythropoietin level was evaluated in tear film and blood plasma of 63 people with emmetropia (30 people) and myopia (33 people). 17 myopic volunteers wear soft contact lens. There were no statistically significant differences between erythropoietin level in tear samples of emmetropic people, myopic people, and people who wear soft contact lens. Physiological level of erythropoietin in tear of myopic volunteers wearing soft contact lens was established.  相似文献   

7.
Yang Y  Yi C  Luo J  Liu R  Liu J  Jiang J  Liu X 《Biosensors & bioelectronics》2011,26(5):2607-2612
A voltammetric glucose sensor was prepared from novel molecularly imprinted polymeric micelles (MIPMs) through direct electrodeposition. The MIPMs, which were photo-crosslinkable and nano-scaled with high specific surface area, were prepared via macromolecule self-assembly of an amphiphilic photo-crosslinkable copolymer, combined with a molecular imprinting technique using glucose as the template molecule. A MIP film was formed in situ on the electrode surface by electrodeposition of the MIPMs, while photo-crosslinking led to a robust film which showed good solvent resistant to dissolution. With these features, the resulting sensor showed good response and selectivity towards glucose. In particular, the linear response of this glucose sensor ranged from 0.2 mM to 8 mM and its comparatively higher detection limit, about 10 mM, indicated numerous effective recognition sites among the polymer matrix due to the large specific surface area of MIPM. In addition, this MIP sensor also showed good stability and reversibility. The contribution of this work lies in not only the invention of a new type of glucose MIP sensor with good performance, but also the creation of a novel strategy to develop advanced MIP sensors for a wide range of templates in viewing of the versatility of the amphiphilic copolymers and the ease of control and applicability of the electrodeposition process.  相似文献   

8.
Pan D  Chen J  Nie L  Tao W  Yao S 《Analytical biochemistry》2004,324(1):115-122
Prussian blue (PB), as a good catalyst for the reduction of hydrogen peroxide, has been combined with nonconducting poly(o-aminophenol) (POAP) film to assemble glucose biosensor. Compared with PB-modified enzymatic biosensor, the biosensor based on glucose oxidase immobilized in POAP film at PB-modified electrode shows much improved stability (78% remains after 30 days) in neutral medium. Additionally, the biosensor, at an applied potential of 0.0 V, exhibits other good characteristics, such as relative low detection limit (0.01 mM), short response time (within 5s), large current density (0.28 mA/cm2), high sensitivity (24 mAM(-1)cm(-2)), and good antiinterferent ability. The apparent activation energy of enzyme-catalyzed reaction and apparent Michaelis-Menten constant are 34.2 KJmol(-1) and 10.5 mM, respectively. In addition, effects of temperature, applied potential used in the determination, pH value of the detection solution, and electroactive interferents on the amperometric response of the sensor were investigated and are discussed.  相似文献   

9.
The in-vivo behaviour of microfabricated GOD (glucose oxidase)/H2O2 glucose sensor implanted subcutaneously in normal anaesthetized rats has been studied. The sensor consists of a planar, three-electrode microcell, an enzyme membrane (glucose oxidase and bovine serum albumin cross-linked with glutaraldehyde) and an outer diffusion limiting polyurethane membrane. The sensor behaviour during hyperglycaemic (13.8 mM and 11.2 mM), euglycaemic (7.8 mM) and hypoglycaemic (3.5 mM) plateau levels was determined. The values of the in-vivo sensitivity (0.64 +/- 0.05 nA/mM) and background current (1.25 +/- 0.4 nA) were determined using a two-point calibration method and then used to calculate apparent subcutaneous glucose concentrations. The results show the presence of a good correlation between all the plasma glucose levels (G) and the apparent subcutaneous tissue concentrations (G'), with G' = 0.997.G - 0.066, r = 0.9782.  相似文献   

10.
Kang X  Mai Z  Zou X  Cai P  Mo J 《Analytical biochemistry》2007,363(1):143-150
Copper (Cu) nanoclusters were electrochemically deposited on the film of a Nafion-solubilized multiwall carbon nanotube (CNTs)-modified glassy carbon electrode (CNTs-GCE), which fabricated a Cu-CNTs composite sensor (Cu-CNTs-GCE) to detect glucose with nonenzyme. Transmission electron microscopy (TEM) and X-ray diffraction (XRD) were used for the characterization of the distribution of the Cu nanoclusters on the CNTs matrix. The composite of the Cu-CNTs was investigated by the electrochemical characterization of cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The preliminary study shows that the nonenzymatic sensor has synergistic electrocatalytic activity to the oxidation of glucose in alkaline media. A well applicable sensor was constructed to use for the analysis of the glucose in real blood serum samples due to the large number of electrons taking part in the oxidation process, the high apparent kinetic rate constant, and the stable operation of the electrode. The linear range for the detection of the glucose is 7.0 x 10(-7) to 3.5 x 10(-3) M with a high sensitivity of 17.76 microA mM(-1), a low detection limit of 2.1 x 10(-7) M, and a fast response time of within 5s. Experiment results also showed that the sensor has good reproducibility and long-term stability and is interference free.  相似文献   

11.
A miniaturized glucose biosensor in which glucose oxidase (GOD) and poly(p-phenylenediamine) (poly-PPD) were coimmobilized at the surface of a platinum microdisk electrode was developed and used successfully for amperometric determination of glucose. The performance of sensors prepared at different monomer concentrations and polymerization potentials with different media was investigated in detail. It was found that similarly to poly(o-phenylenediamine) (poly-OPD), (poly-PPD) noticeably eliminated the electrochemical interference of ascorbic acid, uric acid, and l-cysteine. The amperometric response of glucose with the biosensor under optimal conditions exhibited a linear relationship in the range of 5.0 x 10(-5) to 3.0 x 10(-3) M with correlation coefficient 0.9995. According to the Michaelis-Menten equation, the apparent Michaelis constant for glucose and the maximum steady-state current density of the poly-PPD/GOD-modified microelectrode were 3.94 mM and 607.5 microA cm(-2), respectively. The current density of the sensor responding to glucose in the linear range can reach 160 microA cm(-2) mM(-1), which is far greater than that obtained using poly-OPD and poly(phenol) film. In addition, the stability of the sensor was examined over a 2-month period.  相似文献   

12.
Tear film protein deposition on contact lens hydrogels has been well characterized from the perspective of bacterial adhesion and viability. However, the effect of protein deposition on lens interactions with the corneal epithelium remains largely unexplored. The current study employs a live cell rheometer to quantify human corneal epithelial cell adhesion to soft contact lenses fouled with the tear film protein lysozyme. PureVision balafilcon A and AirOptix lotrafilcon B lenses were soaked for five days in either phosphate buffered saline (PBS), borate buffered saline (BBS), or Sensitive Eyes Plus Saline Solution (Sensitive Eyes), either pure or in the presence of lysozyme. Treated contact lenses were then contacted to a live monolayer of corneal epithelial cells for two hours, after which the contact lens was sheared laterally. The apparent cell monolayer relaxation modulus was then used to quantify the extent of cell adhesion to the contact lens surface. For both lens types, lysozyme increased corneal cell adhesion to the contact lens, with the apparent cell monolayer relaxation modulus increasing up to an order of magnitude in the presence of protein. The magnitude of this increase depended on the identity of the soaking solution: lenses soaked in borate-buffered solutions (BBS, Sensitive Eyes) exhibited a much greater increase in cell attachment upon protein addition than those soaked in PBS. Significantly, all measurements were conducted while subjecting the cells to moderate surface pressures and shear rates, similar to those experienced by corneal cells in vivo.  相似文献   

13.
A sensitive, selective and stable amperometric glucose biosensor employing novel PtPd bimetallic nanoparticles decorated on multi-walled carbon nanotubes (PtPd-MWCNTs) was investigated. PtPd-MWCNTs were prepared by a modified Watanabe method, and characterized by XRD and TEM. The biosensor was constructed by immobilizing the PtPd-MWCNTs catalysts in a Nafion film on a glassy carbon electrode. An inner Na?on film coating was used to eliminate common interferents such as uric acid, ascorbic acid and fructose. Finally, a highly porous surface with an orderly three-dimensional network enzyme layer (CS-GA-GOx) was fabricated by electrodeposition. The resulting biosensor exhibited a good response to glucose with a wide linear range (0.062-14.07 mM) and a low detection limit 0.031 mM. The biosensor also showed a short response time (within 5 s), and a high sensitivity (112 μA mM(-1)cm(-2)). The Michaelis-Menten constant (K(m)) was determined as 3.3 mM. In addition, the biosensor exhibited high reproducibility, good storage stability and satisfactory anti-interference ability. The applicability of the biosensor to actual serum sample analysis was also evaluated.  相似文献   

14.
目的:研究角膜接触镜辅助翼状胬肉切除术对患者泪膜功能及创面上皮的影响。方法:选取2013年7月至2015年6月本院收治74例翼状胬肉切除术患者,根据入院顺序分为观察组和对照组,37例每组。观察组术后加用角膜接触镜,对照组术后使用常规纱布包盖。比较两组患者在术后1 d、5 d、10 d创面上皮愈合情况,术前和术后10 d泪膜功能情况。结果:术后10 d,观察组的Schimer Ⅰ试验、泪膜破裂时间显著长于对照组(P0.05)。术后1 d,观察组角膜上皮愈合率显著高于对照组(P0.05),术后5 d、10 d,观察组和对照组的角膜上皮愈合率比较无显著性差异(P0.05)。结论:角膜接触镜辅助翼状胬肉切除术能改善患者泪膜功能,促进患者创面上皮能在较短时间内恢复。  相似文献   

15.
This paper describes a novel enzymatic amplification strategy for ultrasensitive electrochemical immunosensing. This approach utilizes glucose oxidase for the enzymatic deposition of gold nanoparticles onto an indium tin oxide (ITO) electrode surface using a novel gold developer solution consisting of 20 mM of glucose, 20 mM of NaSCN, 0.5 M of p-benzoquinone (PBQ) and 1 mM of AuCl(4)(-) dissolved in 0.1 M of pH 7.5 phosphate buffer solution. The amount of gold deposited was quantified electrochemically by monitoring the reduction of gold oxide in an aqueous solution of 0.5 M of H(2)SO(4), which was correlated to the amount of antigens in the solution. The effectiveness of this strategy was demonstrated experimentally through the construction of an immunosensor for the detection of mouse IgG using a sandwich immunoassay in a linear dynamic range of 5 pg/ml to 50 ng/ml. A good mean apparent recovery in the range of 88-102% was obtained over the entire linear dynamic range of the sensor response in the serum samples. This suggested that the immunosensor would be useful for the testing of proteins in real clinical samples.  相似文献   

16.
In vivo glucose monitoring is required for tighter glycaemic control. This report describes a new approach to construct a miniature implantable device based on a magnetic acoustic resonance sensor (MARS). A ≈ 600-800 nm thick glucose-responsive poly(acrylamide-co-3-acrylamidophenylboronic acid) (poly(acrylamide-co-3-APB)) film was polymerised on the quartz disc (12 mm in diameter and 0.25 mm thick) of the MARS. The swelling/shrinking of the polymer film induced by the glucose binding to the phenylboronate caused changes in the resonance amplitude of the quartz disc in the MARS. A linear relationship between the response of the MARS and the glucose concentration in the range ≈ 0-15 mM was observed, with the optimum response of the MARS sensor being obtained when the polymer films contained ≈ 20 mol% 3-APB. The MARS glucose sensor also functioned under flow conditions (9 μl/min) with a response almost identical to the sensor under static or non-flow conditions. The results suggest that the MARS could offer a promising strategy for developing a small subcutaneously implanted continuous glucose monitor.  相似文献   

17.
Comparative histochemical and biochemical studies on the catalytically active protease Dipeptidyl peptidase IV (DPPIV), have been performed in the rabbit cornea and the tear fluid using a sensitive fluorogenic substrate, Gly-Pro-7-amino-4-Trifluoromethyl Coumarine (AFC). In both normal and experimentally injured corneas, DPPIV activity was detected histochemically and in the tear fluid biochemically. In contrast to the normal cornea where DPPIV activity was absent and in the tear fluid where it was low, during continuous wearing of contact lenses or repeated irradiation of the cornea with UVB rays, slight DPPIV activity appeared first in the superficial layers of the corneal epithelium, while later increased activity was present in the whole epithelium. This paralleled elevated DPPIV activity in the tear fluid. Moreover, during continuous contact lens wear, the increased DPPIV activity in the tear fluid was, in many cases, coincidental with the presence of capillaries in the limbal part of the corneal stroma. After severe alkali burns when corneal ulcers appeared, collagen fragments were active for DPPIV, which was associated with high DPPIV activity in the tear fluid. In conclusion, Gly-Pro-AFC was found to be useful for comparative histochemical and biochemical studies on DPPIV activity in the experimentally injured rabbit eye. Using the method of the tear film collection by a short touch of substrate punches to the respective site of the cornea or conjunctiva we can show that in experimental injuries (wearing of contact lenses, irradiation of the cornea with UVB rays), the damaged corneal cells were the main source for DPPIV activity in the tear fluid. It is suggested that the activity of DPPIV measured in the tear fluid might serve as an indicator of early corneal disorders, e.g. corneal vascularization related to contact lens wear.  相似文献   

18.
Indirectly heated electrodes operating in a non-isothermal mode have been used as transducers for reagentless glucose biosensors. Pyrroloquinoline quinone-dependent soluble glucose dehydrogenase (PQQ-sGDH) was entrapped on the electrode surface within a redox hydrogel layer. Localized polymer film precipitation was invoked by electrochemically modulating the pH-value in the diffusion zone in front of the electrode. The resulting decrease in solubility of an anodic electrodeposition paint (EDP) functionalized with Osmium complexes leads to precipitation of the redox hydrogel concomitantly entrapping the enzyme. The resulting sensor architecture enables a fast electron transfer between enzyme and electrode surface. The glucose sensor was operated at pre-defined temperatures using a multiple current-pulse mode allowing reproducible indirect heating of the sensor. The sensor characteristics such as the apparent Michaelis constants K(M)(app) and maximum currents I(max)(app) were determined at different temperatures for the main substrate glucose as well as a potential interfering co-substrate maltose. The limit of detection increased with higher temperatures for both substrates (0.020 mM for glucose, and 0.023 mM for maltose at 48 degrees C). The substrate specificity of PQQ-sGDH is highly temperature dependent. Therefore, a mathematical model based on a multiple linear regression approach could be applied to discriminate between the current response for glucose and maltose. This allowed accurate determination of glucose in a concentration range of 0-0.1mM in the presence of unknown maltose concentrations ranging from 0 to 0.04 mM.  相似文献   

19.
The feasibility of dissolved‐core alginate‐templated fluorescent microspheres as “smart tattoo” glucose biosensors was investigated in simulated interstitial fluid (SIF). The sensor works on the principle of competitive binding and fluorescence resonance energy transfer. The sensor consists of multilayer thin film coated alginate microspheres incorporating dye‐labeled glucose receptor and competing ligand within the partially dissolved alginate core. In this study, different approaches for the sensing and detection chemistry were studied, and the response of encapsulated reagents was compared with the solution‐phase counterparts. The glucose sensitivity of the encapsulated TRITC‐Con A/FITC‐dextran (500 kDa) assay in DI water was estimated to be 0.26%/mM glucose while that in SIF was observed to be 0.3%/mM glucose. The glucose sensitivity of TRITC‐apo‐GOx/FITC‐dextran (500 kDa) assay was estimated to be 0.33%/mM glucose in DI water and 0.5%/mM glucose in SIF and both demonstrated a response in the range of 0–50 mM glucose. Therefore, it is hypothesized that the calcium ion concentration outside the microsphere (in the SIF) does not interfere with the response sensitivity. The sensor response was observed to exhibit a maximum response time of 120 s. The system further exhibited a sensitivity of 0.94%/mM glucose with a response in range of 0–50 mM glucose, using near‐infrared dyes (Alexa Fluor‐647‐labeled dextran as donor and QSY‐21‐conjugated apo‐GOx as acceptor), thereby making the sensor more amenable to in vivo use, when implanted in scattering tissue. Biotechnol. Bioeng. 2009; 104: 1075–1085. © 2009 Wiley Periodicals, Inc.  相似文献   

20.
The surface of the eye provides an inert barrier against infection. Through its unique combination of antimicrobial action and anti-inflammatory activities lactoferrin (Lf) in the tear film plays an important role in the maintenance of ocular health. In order to maintain clarity the eye must provide immunological defense without immunopathology. Along with physical barriers, soluble plasma factors and other proteins such as lysozyme, Lf produced by the acinar cells of the lacrimal gland serves a number of roles in defense for this purpose. Lf in tears provides antimicrobial efficacy by binding free iron thus reducing the availability of iron necessary for microbial growth and survival as well as pathogenesis. Lf has been shown to inhibit biofilm formation and thus may play a role in protecting contact lens surfaces from colonization. Virus particles' entry into epithelial cells is inhibited by Lf while an excess of Lf in tear film is thought to limit the opportunistic Lf-mediated bridging of adenovirus and host cell that occurs in other tissues. Lf dampens the classical complement activation pathway by binding to markers of inflammation and immune activation while pathogen-associated molecular patterns such as lipopolysaccharide (LPS) are targeted by Lf for removal through tears and hydrodynamic flushing. This review focuses on the role of Lf in human tear film and its contribution to ocular health during contact lens wear.  相似文献   