首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Images of multiply labeled fluorescent samples provide unique insights into the localization of molecules, cells, and tissues. The ability to image multiple channels simultaneously at high speed without cross talk is limited to a few colors and requires dedicated multichannel or multispectral detection procedures. Simpler microscopes, in which each color is imaged sequentially, produce a much lower frame rate. Here, we describe a technique to image, at high frame rate, multiply labeled samples that have a repeating motion. We capture images in a single channel at a time over one full occurrence of the motion then repeat acquisition for other channels over subsequent occurrences. We finally build a high-speed multichannel image sequence by combining the images after applying a normalized mutual information-based time registration procedure. We show that this technique is amenable to image the beating heart of a double-labeled embryonic quail in three channels (brightfield, yellow, and mCherry fluorescent proteins) using a fluorescence wide-field microscope equipped with a single monochrome camera and without fast channel switching optics. We experimentally evaluate the accuracy of our method on image series from a two-channel confocal microscope.  相似文献   

2.
Visualization of spatiotemporal expression of a gene of interest is a fundamental technique for analyzing the involvements of genes in organ development. In situ hybridization (ISH) is one of the most popular methods for visualizing gene expression. When conventional ISH is performed on sections or whole-mount specimens, the gene expression pattern is represented in 2-dimensional (2D) microscopic images or in the surface view of the specimen. To obtain 3-dimensional (3D) data of gene expression from conventional ISH, the “serial section method” has traditionally been employed. However, this method requires an extensive amount of time and labor because it requires researchers to collect a tremendous number of sections, label all sections by ISH, and image them before 3D reconstruction. Here, we proposed a rapid and low-cost 3D imaging method that can create 3D gene expression patterns from conventional ISH-labeled specimens. Our method consists of a combination of whole-mount ISH and Correlative Microscopy and Blockface imaging (CoMBI). The whole-mount ISH-labeled specimens were sliced using a microtome or cryostat, and all block-faces were imaged and used to reconstruct 3D images by CoMBI. The 3D data acquired using our method showed sufficient quality to analyze the morphology and gene expression patterns in the developing mouse heart. In addition, 2D microscopic images of the sections can be obtained when needed. Correlating 2D microscopic images and 3D data can help annotate gene expression patterns and understand the anatomy of developing organs. These results indicated that our method can be useful in the field of developmental biology.  相似文献   

3.
The whole-cell voltage clamp technique was used to study the slow inward currents and K+ outward currents in single heart cells of embryonic chick and in rabbit aortic cells. In single heart cells of 3-day-old chick embryo three types of slow inward Na+ currents were found. The kinetics and the pharmacology of the slow INa were different from those of the slow ICa in older embryos. Two types of slow inward currents were found in aortic single cells of rabbit; angiotensin II increased the sustained type and d-cAMP and d-cGMP decreased the slow transient component. Two types of outward K+ currents were found in both aortic and heart cells. Single channel analysis demonstrated the presence of a high single K+ channel conductance in aortic cells. In cardiac and vascular smooth muscles, slow inward currents do share some pharmacological properties, although the regulation of these channels by cyclic nucleotides and several drugs seems to be different.  相似文献   

4.
Zebrafish embryo becomes a popular in vivo vertebrate model for studying cardiac development and human heart diseases due to its advantageous embryology and genetics. About 100-200 embryos are readily available every week from a single pair of adult fish. The transparent embryos that develop ex utero make them ideal for assessing cardiac defects. The expression of any gene can be manipulated via morpholino technology or RNA injection. Moreover, forward genetic screens have already generated a list of mutants that affect different perspectives of cardiogenesis. Whole mount immunostaining is an important technique in this animal model to reveal the expression pattern of the targeted protein to a particular tissue. However, high resolution images that can reveal cellular or subcellular structures have been difficult, mainly due to the physical location of the heart and the poor penetration of the antibodies. Here, we present a method to address these bottlenecks by dissecting heart first and then conducting the staining process on the surface of a microscope slide. To prevent the loss of small heart samples and to facilitate solution handling, we restricted the heart samples within a circle on the surface of the microscope slides drawn by an immEdge pen. After the staining, the fluorescence signals can be directly observed by a compound microscope. Our new method significantly improves the penetration for antibodies, since a heart from an embryonic fish only consists of few cell layers. High quality images from intact hearts can be obtained within a much reduced procession time for zebrafish embryos aged from day 2 to day 6. Our method can be potentially extended to stain other organs dissected from either zebrafish or other small animals.  相似文献   

5.
Summary The whole-cell voltage clamp technique was used to study the slow inward currents and K+ outward currents in single heart cells of embryonic chick and in rabbit aortic cells. In single heart cells of 3-day-old chick embryo three types of slow inward Na+ currents were found. The kinetics and the pharmacology of the slow INa, were different from those of the slow Ica in older embryos. Two types of slow inward currents were found in aortic single cells of rabbit; angiotensin 11 increased the sustained type and d-cAMP and d-cGMP decreased the slow transient component. Two types of outward K+ currents were found in both aortic and heart cells. Single channel analysis demonstrated the presence of a high single K+ channel conductance in aortic cells. In cardiac and vascular smooth muscles, slow inward currents do share some pharmacological properties, although the regulation of these channels by cyclic nucleotides and several drugs seems to be different.  相似文献   

6.
Electrical stimulation is the standard technique for exploring electrical behavior of heart muscle, but this approach has considerable technical limitations. Here we report expression of the light-activated cation channel channelrhodopsin-2 for light-induced stimulation of heart muscle in vitro and in mice. This method enabled precise localized stimulation and constant prolonged depolarization of cardiomyocytes and cardiac tissue resulting in alterations of pacemaking, Ca(2+) homeostasis, electrical coupling and arrhythmogenic spontaneous extrabeats.  相似文献   

7.
Abnormal cell mechanical stiffness can point to the development of various diseases including cancers and infections. We report a new microfluidic technique for continuous cell separation utilizing variation in cell stiffness. We use a microfluidic channel decorated by periodic diagonal ridges that compress the flowing cells in rapid succession. The compression in combination with secondary flows in the ridged microfluidic channel translates each cell perpendicular to the channel axis in proportion to its stiffness. We demonstrate the physical principle of the cell sorting mechanism and show that our microfluidic approach can be effectively used to separate a variety of cell types which are similar in size but of different stiffnesses, spanning a range from 210 Pa to 23 kPa. Atomic force microscopy is used to directly measure the stiffness of the separated cells and we found that the trajectories in the microchannel correlated to stiffness. We have demonstrated that the current processing throughput is 250 cells per second. This microfluidic separation technique opens new ways for conducting rapid and low-cost cell analysis and disease diagnostics through biophysical markers.  相似文献   

8.
Fluoroscopic image technique, using either a single image or dual images, has been widely applied to measure in vivo human knee joint kinematics. However, few studies have compared the advantages of using single and dual fluoroscopic images. Furthermore, due to the size limitation of the image intensifiers, it is possible that only a portion of the knee joint could be captured by the fluoroscopy during dynamic knee joint motion. In this paper, we presented a systematic evaluation of an automatic 2D-3D image matching method in reproducing spatial knee joint positions using either single or dual fluoroscopic image techniques. The data indicated that for the femur and tibia, their spatial positions could be determined with an accuracy and precision less than 0.2?mm in translation and less than 0.4° in orientation when dual fluoroscopic images were used. Using single fluoroscopic images, the method could produce satisfactory accuracy in joint positions in the imaging plane (in average up to 0.5?mm in translation and 1.3° in rotation), but large variations along the out-plane direction (in average up to 4.0?mm in translation and 2.2° in rotation). The precision of using single fluoroscopic images to determine the actual knee positions was worse than its accuracy obtained. The data also indicated that when using dual fluoroscopic image technique, if the knee joint outlines in one image were incomplete by 80%, the algorithm could still reproduce the joint positions with high precisions.  相似文献   

9.
基于遥感的建筑物高度快速提取研究综述   总被引:1,自引:0,他引:1  
钱瑶  唐立娜  赵景柱 《生态学报》2015,35(12):3886-3895
近年来我国城市化进程不断推进,不仅体现在城市面积上的增长,也体现在建筑物高度的增长。高度增长一方面能尽量克服城市土地资源匮乏的瓶颈,另一方面为优化城市结构及城市功能做出贡献。在城市遥感研究领域,对于城市建筑物高度的提取也成为研究的重点。城市建筑物高度的估计与测量,已成为城市规划和扩张、城市灾害风险预警与评估的重要参数,同时也为数字城市三维模型的建立提供了基础测绘资料。分别基于光学遥感影像、高分辨率SAR(Synthetic Aperture Radar)影像以及光学遥感影像与高分辨率SAR影像的融合三方面,全面阐述城市建筑物高度的提取方法,并比较两类影像在提取建筑物高度的优劣势,通过回顾早年研究方法,逐步引入近年来新的发展趋势。  相似文献   

10.
Detection of chromosomal aberrations from a single cell by array comparative genomic hybridization (single-cell array CGH), instead of from a population of cells, is an emerging technique. However, such detection is challenging because of the genome artifacts and the DNA amplification process inherent to the single cell approach. Current normalization algorithms result in inaccurate aberration detection for single-cell data. We propose a normalization method based on channel, genome composition and recurrent genome artifact corrections. We demonstrate that the proposed channel clone normalization significantly improves the copy number variation detection in both simulated and real single-cell array CGH data.  相似文献   

11.
Fluoroscopic image technique, using either a single image or dual images, has been widely applied to measure in vivo human knee joint kinematics. However, few studies have compared the advantages of using single and dual fluoroscopic images. Furthermore, due to the size limitation of the image intensifiers, it is possible that only a portion of the knee joint could be captured by the fluoroscopy during dynamic knee joint motion. In this paper, we presented a systematic evaluation of an automatic 2D–3D image matching method in reproducing spatial knee joint positions using either single or dual fluoroscopic image techniques. The data indicated that for the femur and tibia, their spatial positions could be determined with an accuracy and precision less than 0.2 mm in translation and less than 0.4° in orientation when dual fluoroscopic images were used. Using single fluoroscopic images, the method could produce satisfactory accuracy in joint positions in the imaging plane (in average up to 0.5 mm in translation and 1.3° in rotation), but large variations along the out-plane direction (in average up to 4.0 mm in translation and 2.2° in rotation). The precision of using single fluoroscopic images to determine the actual knee positions was worse than its accuracy obtained. The data also indicated that when using dual fluoroscopic image technique, if the knee joint outlines in one image were incomplete by 80%, the algorithm could still reproduce the joint positions with high precisions.  相似文献   

12.
By use of the patch-clamp technique, the inner membrane of mouse liver and heart mitochondria is shown to contain a highly conductive (around 100 pS in symmetrical 150 mM KCl) and voltage-dependent ion channel. This channel closely resembles that previously found in cuprizone-treated mouse liver inner mitochondrial membrane. The paper discusses the electrical properties of the channel and its possible physiological function. The reconstitution in giant liposomes of a partially purified ox heart inner membrane fraction containing the channel and the use of various inhibitors are also presented.  相似文献   

13.
We present a robust, low-cost single-shot implementation of differential phase microscopy utilising a polarisation-sensitive camera to simultaneously acquire four images from which phase contrast images can be calculated. This polarisation-resolved differential phase contrast (pDPC) microscopy technique can be easily integrated with fluorescence microscopy.  相似文献   

14.
63 adult rabbits were used to stimulate single physical exercise, acute and relapsing coronary insufficiency, alimentary atherosclerosis and to study adaptive and pathologic changes in the lymphatic channel (LC) of the heart. LC of the heart in animals with alimentary atherosclerosis after cholesterol exclusion from their diet was studied to determine reversibility of these changes. LC of the heart was injected by differently coloured masses and was investigated by the stereoangioscopic method on clarified preparations, on semithin sections and by the electron-microscopic method. Changes in different elements of a lymphatic net were of the stereotype character, as a whole. Morphofunctional reactions determining the development of the chronic insufficiency of the lymph flow in the heart form as successively following phases which change both due to exposition of the pathological process-initiated effect and due to certain endogenic factors arising during arrangement of LC of the heart.  相似文献   

15.
A three-dimensional digital image correlation technique is presented for strain measurements in open-cell structures such as trabecular bone. The technique uses high-resolution computed tomography images for displacement measurements in the solid structure. In order to determine the local strain-state within single trabeculae, a tetrahedronization method is used to fill the solid structure with tetrahedrae. Displacements are calculated at the nodes of the tetrahedrae. The displacement data is subsequently converted to a deformation tensor in each of the tetrahedral element centers with a least-squares estimation method. Because the trabeculae are represented by a mesh, it is possible to deform this mesh according to the deformation tensor and, at the same time, visualize the calculated local strain in the deformed mesh with a finite element post-processing tool. In this way, the deformation of a single trabecula from an aluminum foam sample was determined and validated with rendered images of the three-dimensional sample. A precision analysis showed that a rigid translation or rotation does not affect the accuracy. Typical values for the standard deviation in the displacement and strain components are 2.0 microm and 0.01, respectively. Presently, the precision limits the technique to strain measurements beyond the yield strain.  相似文献   

16.
We present a multimodal in vivo skin imaging instrument that is capable of simultaneously acquiring multiphoton and reflectance confocal images at up to 27 frames per second with 256 × 256 pixel resolution without the use of exogenous contrast agents. A single femtosecond laser excitation source is used for all channels ensuring perfect image registration between the two‐photon fluorescence (TPF), second harmonic generation (SHG), and reflectance confocal microscopy (RCM) images. Images and videos acquired with the system show that the three imaging channels provide complementary information in in vivo human skin measurements. In the epidermis, cell boundaries are clearly seen in the RCM channel, while cytoplasm is better seen in the TPF imaging channel, whereas in the dermis, SHG and TPF channels show collagen bundles and elastin fibers, respectively. The demonstrated fast imaging speed and multimodal imaging capabilities of this MPM/RCM instrument are essential features for future clinical application of this technique. (© 2013 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

17.
The polypeptide hormone atrial natriuretic peptide (ANP) plays vital roles in maintaining blood volume and arterial blood pressure. The recognition of clinical benefits of ANP both in healthy and diseased heart identifies ANP as a potential candidate for therapeutic strategy in the treatment of heart disease. ANP is synthesized and stored in cardiac myocytes and it is released through the exocytosis of ANP granules both constitutively and in response to stimuli. It is well known that mechanical stretch is the predominant stimulus for ANP secretion. However, the mechanistic link between mechanical stimuli and exocytosis of ANP vesicles in single atrial myocyte has not yet been demonstrated. Over the last decade, compelling evidence suggested that stretch-activated ion channels might function as mechanosensors. We showed previously that direct stretch of single atrial myocyte using two micro-electrodes activated a non-selective cation channel (SAC). So far it is not known whether activation of SAC is involved in stretch-induced ANP secretion. The present article aims to give an overview of the mechanism of mechanical stretch-stimulated ANP secretion and describes an innovative technique to detect ANP secretion from isolated rat atrial myocytes with high time-resolution. Combined with capacitance measurement and patch-clamp technique in conjunction with in situ ANP bioassay, we were able to demonstrate that SAC in rat atrial myocytes acts as a mechanosensor to transduce stretch signals into the ANP secretion pathway.  相似文献   

18.
Cyst initiation and expansion during polycystic kidney disease is a complex process characterized by abnormalities in tubular cell proliferation, luminal fluid accumulation and extracellular matrix formation. Activity of ion channels and intracellular calcium signaling are key physiologic parameters which determine functions of tubular epithelium. We developed a method suitable for real-time observation of ion channels activity with patch-clamp technique and registration of intracellular Ca2+ level in epithelial monolayers freshly isolated from renal cysts. PCK rats, a genetic model of autosomal recessive polycystic kidney disease (ARPKD), were used here for ex vivo analysis of ion channels and calcium flux. Described here is a detailed step-by-step procedure designed to isolate cystic monolayers and non-dilated tubules from PCK or normal Sprague Dawley (SD) rats, and monitor single channel activity and intracellular Ca2+ dynamics. This method does not require enzymatic processing and allows analysis in a native setting of freshly isolated epithelial monolayer. Moreover, this technique is very sensitive to intracellular calcium changes and generates high resolution images for precise measurements. Finally, isolated cystic epithelium can be further used for staining with antibodies or dyes, preparation of primary cultures and purification for various biochemical assays.  相似文献   

19.
Image shift due to beam-induced specimen charging has become the most severe problem in electron microscopy for imaging two-dimensional (2D) crystals of biological macromolecules, especially in the case of highly tilted specimens. Image shift causes diffraction spots perpendicular to the tilt axis to disappear even at medium or low resolution. The yield of good images from tilted specimens prepared on a single layer of continuous carbon support film is therefore very low. In this paper, we have used 2D crystals of aquaporin-4 to investigate the effect of a carbon sandwich preparation method on specimen charging. We find that a larger number of images show sharp diffraction spots perpendicular to the tilt axis if crystals are placed in between two sheets of carbon film as compared to images taken from specimens prepared by the conventional single carbon support film technique. Our results demonstrate that the reproducible carbon sandwich preparation technique overcomes the severe specimen charging problem and thus has the potential to significantly speed up structure analysis by electron crystallography.  相似文献   

20.
Single Na channel currents were compared in ventricular myocytes and cortical neurons of neonatal rats using the gigaseal patch-clamp method to determine whether tissue-specific differences in gating can be detected at the single-channel level. Single-channel currents were recorded in cell-attached and excised membrane patches at test potentials of -70 to -20 mV and at 9-11 degrees C. In both cell-attached and excised patches brain Na channel mean open time progressively increased from less than 1 ms at -70 mV to approximately 2 ms at -20 mV. Near threshold, single openings with dispersed latencies were observed. By contrast, in cell-attached patches, heart Na channel mean open time peaked near -50 mV, was three times brain Na channel mean open time, and declined continuously to approximately 2 ms at -20 mV. Near threshold, openings occurred frequently usually as brief bursts lasting several milliseconds and rarely as prolonged bursts lasting tens of milliseconds. Unlike what occurs in brain tissue where excision did not change gating, in excised heart patches both the frequency of prolonged bursting and the mean open time of single units increased markedly. Brain and cardiac Na channels can therefore be distinguished on the basis of their mean open times and bursting characteristics.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号