首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
PurposeTo verify the accuracy of 4D Monte Carlo (MC) simulations, using the 4DdefDOSXYZnrc user code, in a deforming anatomy. We developed a tissue-equivalent and reproducible deformable lung phantom and evaluated 4D simulations of delivered dose to the phantom by comparing calculations against measurements.MethodsA novel deformable phantom consisting of flexible foam, emulating lung tissue, inside a Lucite external body was constructed. A removable plug, containing an elastic tumor that can hold film and other dosimeters, was inserted in the phantom. Point dose and position measurements were performed inside and outside the tumor using RADPOS 4D dosimetry system. The phantom was irradiated on an Elekta Infinity linac in both stationary and moving states. The dose delivery was simulated using delivery log files and the phantom motion recorded with RADPOS.ResultsReproducibility of the phantom motion was determined to be within 1 mm. The phantom motion presented realistic features like hysteresis. MC calculations and measurements agreed within 2% at the center of tumor. Outside the tumor agreements were better than 5% which were within the positional/dose reading uncertainties at the measurement points. More than 94% of dose points from MC simulations agreed within 2%/2 mm compared to film measurements.ConclusionThe deformable lung phantom presented realistic and reproducible motion characteristics and its use for verification of 4D dose calculations was demonstrated. Our 4DMC method is capable of accurate calculations of the realistic dose delivered to a moving and deforming anatomy during static and dynamic beam delivery techniques.  相似文献   

2.
Application of neutrons to cancer treatment has been a subject of considerable clinical and research interest since the discovery of the neutron by Chadwick in 1932 (3). Boron neutron capture therapy (BNCT) is a technique of radiation oncology which is used in treating brain cancer (glioblastoma multiform) or melanoma and that consists of preferentially loading a compound containing 10B into the tumor location, followed by the irradiation of the patient with a beam of neutron. Dose distribution for BNCT is mainly based on Monte Carlo simulations. In this work, the absorbed dose spatial distribution resultant from an idealized neutron beam incident upon ahead phantom is investigated using the Monte Carlo N-particles code, MCNP 4B. The phantom model used is based on the geometry of a circular cylinder on which sits an elliptical cylinder capped by half an ellipsoid representing the neck and head, both filled with tissue-equivalent material. The neutron flux and the contribution of individual absorbed dose components, as a function of depths and of radial distance from the beam axis (dose profiles) in phantom model, is presented and discussed. For the studied beam the maximum thermal neutron flux is at a depth of 2 cm and the maximum gamma dose at a depth of 4 cm.  相似文献   

3.
BackgroundThe calculation and measurement on the surface of the skin presents a significant dosimetric problem because of numerous factors which have an influence on the dose distribution in this region.AimThe overall aim of this study was to check the agreement between doses measured with thermoluminescent detectors (TLD) during tomotherapy photon beam irradiation of the skin area of a solid water cylindrical phantom with doses calculated with Hi-Art treatment planning system (TPS).Material and MethodThe measurements of the dose were made with the use of a solid water cylindrical phantom - Cheese Phantom. Two bolus phantoms were used: 5 mm and 10 mm Six different planning treatments were generated. The doses were measured using TL detectors.ResultsIn the case of a tumor located near the surface of the skin, the mean dose for 0.5 cm bolus was - 1.94 Gy, and for 1 cm bolus - 2.03 Gy. For the tumor located inside the phantom and organ at risk on the same side that TL detectors, for a 0.5 cm bolus, mean dose was 0.658 Gy, and for a 1 cm bolus, 0.62 Gy.ConclusionThe analysis of results showed that the relative percentage difference between measured and planned dose in the field of irradiation was less than 10%, while the largest differences were on the board of the field of radiation and outside of the field of irradiation, where the dose was 0.08 Gy to 1 Gy.  相似文献   

4.
The purpose of the present study is to perform a clinical validation of a new commercial Monte Carlo (MC) based treatment planning system (TPS) for electron beams, i.e. the XiO 4.60 electron MC (XiO eMC). Firstly, MC models for electron beams (4, 8, 12 and 18 MeV) have been simulated using BEAMnrc user code and validated by measurements in a homogeneous water phantom. Secondly, these BEAMnrc models have been set as the reference tool to evaluate the ability of XiO eMC to reproduce dose perturbations in the heterogeneous phantom. In the homogeneous phantom calculations, differences between MC computations (BEAMnrc, XiO eMC) and measurements are less than 2% in the homogeneous dose regions and less than 1 mm shifting in the high dose gradient regions. As for the heterogeneous phantom, the accuracy of XiO eMC has been benchmarked with predicted BEAMnrc models. In the lung tissue, the overall agreement between the two schemes lies under 2.5% for the most tested dose distributions at 8, 12 and 18 MeV and is better than the 4 MeV one. In the non-lung tissue, a good agreement has been found between BEAMnrc simulation and XiO eMC computation for 8, 12 and 18 MeV. Results are worse in the case of 4 MeV calculations (discrepancies ≈ 4%). XiO eMC can predict dose perturbation induced by high-density heterogeneities for 8, 12 and 18 MeV. However, significant deviations found in the case of 4 MeV demonstrate that caution is necessary in using XiO eMC at lower electron energies.  相似文献   

5.
【背景】定陶王墓地M2汉墓出土了一批处于防护层的重要汉砖,目前部分汉砖表面出现了真菌病害问题。【目的】根据现场文物保护状况,选取了5块汉砖表面的微生物病害样本,检测并分析了汉砖表面的真菌病害,将分离得到的7株真菌进行抑菌试验。【方法】使用扫描电镜观察、高通量测序、纯培养和抑菌试验等方法对样本中的真菌进行分析。【结果】发现未经抑菌处理的汉砖表面真菌病害问题严重,经75%乙醇和0.5%硝酸咪康唑处理过的汉砖表面真菌病害问题减弱。汉砖上的主要真菌不同,汉砖9表面含量最多的真菌为Boeremia,汉砖13表面含量最多的为虫草科(Cordycipitaceae)。然而硝酸咪康唑和硼酸硼砂并无抑菌效果,抑菌产品K100(2-甲基-4-异噻唑啉-3-酮)具有较好的抑菌效果。【结论】本研究对分析和防治汉砖表面的真菌病害及对汉砖进行科技保护具有重要意义。  相似文献   

6.
Organ or tissue equivalent dose, the most important quantity in radiation protection, cannot be measured directly. Therefore it became common practice to calculate the quantity of interest with Monte Carlo methods applied to so-called human phantoms, which are virtual representations of the human body. The Monte Carlo computer code determines conversion coefficients, which are ratios between organ or tissue equivalent dose and measurable quantities. Conversion coefficients have been published by the ICRP (Report No. 74) for various types of radiation, energies and fields, which have been calculated, among others, with the mathematical phantoms ADAM and EVA. Since then progress of image processing, and of clock speed and memory capacity of computers made it possible to create so-called voxel phantoms, which are a far more realistic representation of the human body. Voxel (Volume pixel) phantoms are built from segmented CT and/or MRI images of real persons. A complete set of such images can be joined to a 3-dimensional representation of the human body, which can be linked to a Monte Carlo code allowing for particle transport calculations. A modified version of the VOX_TISS8 human voxel phantom (Yale University) has been connected to the EGS4 Monte Carlo code. The paper explains the modifications, which have been made, the method of coupling the voxel phantom with the code, and presents results as conversion coefficients between organ equivalent dose and kerma in air for external photon radiation. A comparison of the results with published data shows good agreement.  相似文献   

7.
Radiation and Environmental Biophysics - Rod sources are a common tool for the calibration of whole-body counters in combination with the Saint-Petersburg brick phantom. Here, a method for the...  相似文献   

8.
PurposeIn radiotherapy, accurate calculation of patient radiation dose is very important for good clinical outcome. In the presence of metallic implants, the dose calculation accuracy could be compromised by metal artefacts generated in computed tomography (CT) images of patients. This study investigates the influence of metal-induced CT artefacts on MC dose calculations in a pelvic prosthesis phantom.MethodsA pelvic phantom containing unilateral Ti prosthesis was CT-scanned and accurate Hounsfield unit (HU) values were assigned to known materials of the phantom as opposed to HU values produced through the artefact CT images of the phantom. Using the DOSXYZnrc MC code, dose calculations were computed in the phantom model constructed from the original CT images containing the artefacts and artefact-free images made from the exact geometry of the phantom with known materials. The dose calculations were benchmarked against Gafchromic EBT3 film measurements using 15 MeV electron and 10 MV photon beams.ResultsThe average deviations between film and MC dose data decreased from 3 ± 2% to 1 ± 1% and from about 6 ± 2% to 3 ± 1% for the artefact and artefact-free phantom models against film data for the electron and photon fields, respectively.ConclusionsFor the Ti prosthesis phantom, the presence of metal-induced CT artefacts could cause dose inaccuracies of about 3%. Construction of an artefact-free phantom model made from the exact geometry of the phantom with known materials to overcome the effect of artefacts is advantageous compared to using CT data directly of which the exact tissue composition is not well-known.  相似文献   

9.
Summary. Holospora obtusa is a Gram-negative bacterium inhabiting the macronucleus of the ciliate Paramecium caudatum. Experimental infection with H. obtusa was carried out under nocodazole treatment. Nocodazole has been shown to cause disassembly of the cytoplasmic microtubules radiating from the cytopharynx and postoral fibers in P. caudatum. Treatment with this drug did not prevent the ingestion of both prey bacteria and H. obtusa, but it reduced the phagosome number and affected cyclosis. In situ hybridization revealed infectious forms of this endobiont very close to the macronucleus, but never inside it. These results indicate that disassembly of microtubules does not impair transportation of the infectious forms of H. obtusa in the cytoplasm, but that it completely blocks the invasion of the nucleus by the bacteria. Correspondence and reprints: Department of Cytology and Histology, Faculty of Biology and Soil Sciences, Saint Petersburg State University, Universitetskaya naberezhnaya 7/9, 199034 Saint Petersburg, Russia.  相似文献   

10.
Computational anthropomorphic phantoms have become an important investigation tool for medical imaging and dosimetry for radiotherapy and radiation protection. The development of computational phantoms with realistic anatomical features contribute significantly to the development of novel methods in medical physics. For many applications, it is desirable that such computational phantoms have a real-world physical counterpart in order to verify the obtained results.In this work, we report the development of a voxelised phantom, the HIGH_RES_HEAD, modelling a paediatric head based on the commercial phantom 715-HN (CIRS). HIGH_RES_HEAD is unique for its anatomical details and high spatial resolution (0.18 × 0.18 mm2 pixel size). The development of such a phantom was required to investigate the performance of a new proton computed tomography (pCT) system, in terms of detector technology and image reconstruction algorithms.The HIGH_RES_HEAD was used in an ad-hoc Geant4 simulation modelling the pCT system. The simulation application was previously validated with respect to experimental results. When compared to a standard spatial resolution voxelised phantom of the same paediatric head, it was shown that in pCT reconstruction studies, the use of the HIGH_RES_HEAD translates into a reduction from 2% to 0.7% of the average relative stopping power difference between experimental and simulated results thus improving the overall quality of the head phantom simulation.The HIGH_RES_HEAD can also be used for other medical physics applications such as treatment planning studies.A second version of the voxelised phantom was created that contains a prototypic base of skull tumour and surrounding organs at risk.  相似文献   

11.
Focused ultrasound has been used to elicit cutaneous tactile, thermal, specific and nonspecific pain sensations, and also subcutaneous (deep) sensations which included tactile and some pain sensations (muscular and periosteal etc.). It has been found that somatic reception can be attributed to mechanoreception, that the same receptive structures are involved in the sensations of warmth and cold, and that ultrasound has a sensitizing action. Studies have been made of sensation differences from corporal and auricular acupuncture points, and from some chosen skin and subcutaneous points.I. M. Sechenov Institute of Evolutionary Physiology and Biochemistry, Russian Academy of Sciences, Saint Petersburg. I. P. Pavlov Institute of Physiology, Russian Academy of Sciences, Saint Petersburg. Translated from Neirofiziologiya, Vol. 24, No. 5, pp. 529–534, September–October, 1992.  相似文献   

12.
Computational phantoms with articulated arms and legs have been constructed to enable the estimation of radiation dose in different postures. Through a graphical user interface, the Phantom wIth Moving Arms and Legs (PIMAL) version 4.1.0 software can be employed to articulate the posture of a phantom and generate a corresponding input deck for the Monte Carlo N-Particle (MCNP) radiation transport code. In this work, photon fluence-to-dose coefficients were computed using PIMAL to compare organ and effective doses for a stylized phantom in the standard upright position with those for phantoms in realistic work postures. The articulated phantoms represent working positions including fully and half bent torsos with extended arms for both the male and female reference adults. Dose coefficients are compared for both the upright and bent positions across monoenergetic photon energies: 0.05, 0.1, 0.5, 1.0, and 5.0 MeV. Additionally, the organ doses are compared across the International Commission on Radiological Protection’s standard external radiation exposure geometries: antero-posterior, postero-anterior, left and right lateral, and isotropic (AP, PA, LLAT, RLAT, and ISO). For the AP and PA irradiation geometries, differences in organ doses compared to the upright phantom become more profound with increasing bending angles and have doses largely overestimated for all organs except the brain in AP and bladder in PA. In LLAT and RLAT irradiation geometries, energy deposition for organs is more likely to be underestimated compared to the upright phantom, with no overall change despite increased bending angle. The ISO source geometry did not cause a significant difference in absorbed organ dose between the different phantoms, regardless of position. Organ and effective fluence-to-dose coefficients are tabulated. In the AP geometry, the effective dose at the 45° bent position is overestimated compared to the upright phantom below 1 MeV by as much as 27% and 82% in the 90° position. The effective dose in the 45° bent position was comparable to that in the 90° bent position for the LLAT and RLAT irradiation geometries. However, the upright phantom underestimates the effective dose to PIMAL in the LLAT and RLAT geometries by as much as 30% at 50 keV.  相似文献   

13.
PurposeThe dose calculated using a convolution algorithm should be validated in a simple homogeneous water-equivalent phantom before clinical use. The dose calculation accuracy within a solid water phantom was investigated.MethodsThe specific Gamma knife design requires a dose rate calibration within a spherical solid water phantom. The TMR10 algorithm, which approximates the phantom material as liquid water, correctly computes the absolute dose in water. The convolution algorithm, which considers electron density miscalculates the dose in water as the phantom Hounsfield units were converted into higher electron density when the original CT calibration curve was used. To address this issue, the electron density of liquid water was affected by modifying the CT calibration curve. The absolute dose calculated using the convolution algorithm was compared with that computed by the TMR10. The measured depth dose profiles were also compared to those computed by the convolution and TMR10 algorithms. A patient treatment was recalculated in the solid-water phantom and the delivery quality assurance was checked.ResultsThe convolution algorithm and the TMR10 calculate an absolute dose within 1% when using the modified CT calibration curve. The dose depth profile calculated using the convolution algorithms was superimposed on the TMR10 and measured dose profiles when the modified CT calibration curve was applied. The Gamma index was better than 93%.ConclusionsDose calculation algorithms, which consider electron density, require a CT calibration curve adapted to the phantom material to correctly compute the dose in water.  相似文献   

14.
Neutron dose coefficients for standard irradiation geometries have been reported in International Commission on Radiological Protection (ICRP) Publication 116 for the ICRP Publication 110 adult reference phantoms. In the present work, organ and effective dose coefficients have been calculated for a receptor in both upright and articulated (bent) postures representing more realistic working postures exposed to a mono-energetic neutron radiation field. This work builds upon prior work by Dewji and co-workers comparing upright and bent postures for exposure to mono-energetic photon fields. Simulations were conducted using the Oak Ridge National Laboratory’s articulated stylized adult phantom, “Phantom wIth Moving Arms and Legs” (PIMAL) software package, and the Monte Carlo N-Particle (MCNP) version 6.1.1 radiation transport code. Organ doses were compared for the upright and bent (45° and 90°) phantom postures for neutron energies ranging from 1 × 10??9 to 20 MeV for the ICRP Publication 116 external exposure geometries—antero-posterior (AP), postero-anterior (PA), and left and right lateral (LLAT, RLAT). Using both male and female phantoms, effective dose coefficients were computed using ICRP Publication 103 methodology. The resulting coefficients for articulated phantoms were compared to those of the upright phantom. Computed organ and effective dose coefficients are discussed as a function of neutron energy, phantom posture, and source irradiation geometry. For example, it is shown here that for the AP and PA irradiation geometries, the differences in the organ coefficients between the upright and bent posture become more pronounced with increasing bending angle. In the AP geometry, the brain dose coefficients are expectedly higher in the bent postures than in the upright posture, while all other organs have lower dose coefficients, with the thyroid showing the greatest difference. Overall, the effective dose estimated for the upright phantom is more conservative than that for the articulated phantom, which may have ramifications in the estimation or reconstruction of radiation doses.  相似文献   

15.
Paloverde is a new program designed to help visualize the phylogenetic structure of moderately large trees--trees on the scale of 100-2500 leaf nodes. The program embeds the user in an interactive virtual 3D world in which a large tree presented in various layouts can be manipulated through a mouse interface. The program implements radial 2D layouts, and true 3D spiral, conical and hemispherical (i.e. truly 'tree'-like) layouts. Subclades can be defined in the input file (using standard node-based definitions) and displayed collapsed as new leaf nodes, or left intact but annotated with names around the periphery of the tree. A search tool lets the user zoom to any selected leaf node. Paloverde is an open source project written in ANSI C using the OpenGL library for 3D visualization. Availability: Source code, makefiles for Mac OS X and Linux and a compiled binary for Mac OS X are available at http://ginger.ucdavis.edu/paloverde/paloverde.html, along with a sample dataset.  相似文献   

16.
IntroductionA mathematical 3D model of an existing computed tomography (CT) scanner was created and used in the EGSnrc-based BEAMnrc and egs_cbct Monte Carlo codes. Simulated transmission dose profiles of a RMI-465 phantom were analysed to verify Hounsfield numbers against measured data obtained from the CT scanner.Methods and materialsThe modelled CT unit is based on the design of a Toshiba Aquilion 16 LB CT scanner. As a first step, BEAMnrc simulated the X-ray tube, filters, and secondary collimation to obtain phase space data of the X-ray beam. A bowtie filter was included to create a more uniform beam intensity and to remove the beam hardening effects. In a second step the Interactive Data Language (IDL) code was used to build an EGSPHANT file that contained the RMI phantom which was used in egs_cbct simulations. After simulation a series of profiles were sampled from the detector model and the Feldkamp-Davis-Kress (FDK) algorithm was used to reconstruct transversal images. The results were tested against measured data obtained from CT scans.ResultsThe egs_cbct code can be used for the simulation of a fan beam CT unit. The calculated bowtie filter ensured a uniform flux on the detectors. Good correlation between measured and simulated CT numbers was obtained.ConclusionsIn principle, Monte Carlo codes such as egs_cbct can model a fan beam CT unit. After reconstruction, the images contained Hounsfield values comparable to measured data.  相似文献   

17.
PurposeFeasability of a no-reference image quality metric was assessed on patient-like images using a patient-specific phantom simulating a frame of a coronary angiogram.MethodsOne background and one contrast-filled frame of a coronary angiogram, acquired using a clinical imaging protocol, were selected from a Philips Integris Allura FD (Philips Healthcare, Best, The Netherlands). The background frame’s pixels were extruded to a thickness proportional to their grey value. One phantom was 3D printed using composite 80% bronze filament (max. thickness of 5.1 mm), the other was a custom PMMA cast (max thickness of 8.5 cm). A vessel mold was created from the contrast-filled frame and injected with a solution of 320 mg I/ml contrast fluid (75%), water and gelatin. Still X-ray frames of the vessel mold + background phantom + 16 cm PMMA were acquired at manually selected different exposure settings using a Philips Azurion (Philips Healthcare, Best, The Netherlands) in User Quality Control Mode and were exported as RAW images. The signal-difference-to-noise-ratio-squared (SDNR2) and a spatial-domain-equivalent of the noise equivalent quanta (NEQSDE) were calculated. The Spearman’s correlation of the latter parameters with a no-reference perceptual image quality metric (NIQE) was investigated.ResultsThe bronze phantom showed better resemblance to the original patient frame selected from a coronary angiogram of an actual patient, with better contrast and less blur than the PMMA phantom. Both phantoms were imaged using a comparable imaging protocol to the one used to acquire the original frame. The bronze phantom was hence used together with the vessel mold for image quality measurements on the 165 still phantom frames. A strong correlation was noted between NEQSDE and NIQE (SROCC = –0.99, p < 0.0005) and between SDNR2 and NIQE (SROCC = –0.97, p < 0.0005).ConclusionUsing a cost-effective and easy to realize patient-specific phantom we were able to generate patient-like X-ray frames. NIQE as a no-reference image quality model has the potential to predict physical image quality from patient images.  相似文献   

18.
There are laws which protect and prevent the teenage girls from working. But still in the developing countries like India, Bangladesh, etc. teenage girls coming from low socio-economic background work, to add to the family income. There is dearth of data regarding the ergonomic studies of the teenage girls working in the manual brick manufacturing units of the unorganized sectors in India. Therefore, a field study was conducted in about four brick manufacturing units of West Bengal, India. Their job in these fields was to carry 8-10 unbaked and sun-dried bricks (49.11 +/- 2.13 Kg) from the brick field to the kiln-top and again carry the baked bricks back from the kiln to some other corner of the brick field, under the hot sun. Thus, this study aimed at evaluating their work load and their consequent work-related health effects. Results show that 86 % of them suffered from work-related pain in different body parts and there was an increase in their physiological and psychological parameters after work. It is concluded that the frequent use of awkward postures while at work (OWAS) and performing heavy to moderate types of tasks in the field are deteriorating their health conditions.  相似文献   

19.
The feasibility of reducing the differences between patient-specific internal doses and doses estimated using reference phantoms was evaluated. Relatively simple adjustments to a polygon-surface ICRP adult male reference phantom were applied to fit selected individual dimensions using the software Rhinoceros®4.0. We tested this approach on two patient-specific phantoms: the biggest and the smallest phantoms from the Helmholtz Zentrum München library. These phantoms have unrelated anatomy and large differences in body-mass-index. Three models approximating each patient’s anatomy were considered: the voxel and the polygon-surface ICRP adult male reference phantoms and the adjusted polygon-surface reference phantom. The Specific Absorbed Fractions (SAFs) for internal photon and electron sources were calculated with the Monte Carlo code EGSnrc. Employing the time-integrated activity coefficients of a radiopharmaceutical (S)-4-(3-18F-fluoropropyl)-l-glutamic acid and the calculated SAFs, organ absorbed-dose coefficients were computed following the formalism promulgated by the Committee on Medical Internal Radiation Dose. We compared the absorbed-dose coefficients between each patient-specific phantom and other models considered with emphasis on the cross-fire component. The corresponding differences for most organs were notably lower for the adjusted reference models compared to the case when reference models were employed. Overall, the proposed approach provided reliable dose estimates for both tested patient-specific models despite the pronounced differences in their anatomy. To capture the full range of inter-individual anatomic variability more patient-specific phantoms are required. The results of this test study suggest a feasibility of estimating patient-specific doses within a relative uncertainty of 25% or less using adjusted reference models, when only simple phantom scaling is applied.  相似文献   

20.
Abstract

Rudkhan Castle, one of the most valuable monuments in Iran, belongs to the Sasanian Empire, and nearly all of the parts are made of bricks. The castle had been exposed to physicochemical and biological factors over the years. Locating in a humid environment and possessing porous surface has made it appropriate substrata for microorganisms’ colonization. This study is an attempt to identify the major microorganisms involved in biodeterioration of Rudkhan Castle. The samples were taken from brick surfaces and were sub-cultured onto culture media. Scanning electron microscope (SEM), stereomicroscope and Periodic Acid Schiff (PAS) staining were also employed to illustrate the growth and pattern of penetration into the substratum. Energy dispersion X-ray analysis (EDX) and X-ray diffraction (XRD) were used to show alteration of elements of deteriorated brick samples, which are caused by microorganisms’ activities. First, Samples were identified by morphological characteristics. Next, some of the isolates were identified according to molecular methods, polymerase chain reaction (PCR). The first step to protect the cultural heritage is identification of deteriorating agents.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号