首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Molecularly imprinted polyaniline (PANI) film (~ 100 nm thick) has been electrochemically fabricated onto indium-tin-oxide (ITO) coated glass plate using ascorbic acid (AA) as template molecule. Fourier transform infra-red spectroscopy, scanning electron microscopy, cyclic voltammetry and differential pulse voltammetry (DPV) studies indicate the presence of AA in PANI matrix, which also acts as a dopant for PANI. Further, the AA selective molecularly imprinted PANI electrode (AA-MI-PANI/ITO) has been developed via over-oxidation of AA doped PANI electrode which leads to the removal of AA moieties from PANI film. The response studies using DPV technique have revealed that this molecularly imprinted AA-MI-PANI/ITO electrode can detect AA in the range of 0.05-0.4 mM with detection limit of 0.018 mM and sensitivity of 1.2 × 10(-5) AmM(-1). Interestingly, this AA-MI-PANI/ITO electrode shows excellent reusability, selectivity and stability.  相似文献   

2.
A sensitive and selective amperometric glucose biosensor based on platinum microparticles dispersed in nano-fibrous polyaniline (PANI) was investigated. Poly (m-phenylenediamine) (PMPD), which was employed as an anti-interferent barrier and a protective layer to platinum microparticles, was deposited onto platinum-modified PANI in the presence of glucose oxidase. The morphology of PANI, Pt/PANI and PMPD-GOD/Pt/PANI were investigated by scanning electron microscopy. The results show that PANI has a nano-fibrous morphology. The enzyme electrode exhibits excellent response performance to glucose with linear range from 2 x 10(-6) to 12 x 10(-3) M and fast response time within 7s. Due to the selective permeability of PMPD, the enzyme electrode also shows good anti-interference to uric acid and ascorbic acid. The Michaelis-Menten constant km and the maximum current density imax of the enzyme electrode were 9.34 x 10(-3) M and 917.43 microA cm(-2), respectively. Furthermore, this glucose biosensor also has good stability and reproducibility.  相似文献   

3.
Electrochemical polymerization of acacia gum (AG) was initiated by electroactive polyaniline (PANI) monomers by radical cation formation and their coupling reactions with AG molecules. RCT values obtained from electrochemical impedance spectroscopy analysis at various AG concentrations with PANI were drastically decreased, confirming formation of conducting AG complexes with PANI. Quantitative analysis of ochratoxin-A (OTA) detection in electrolyte was carried out on rabbit antibody-immobilized PANI and PANI–AG matrices. The observed sensitivities of 50, 150, and 250 mg AG-added PANI matrix-based platforms were 3.3 ± 0.5, 10.0 ± 0.5, and 12.7 ± 0.5 μA/ng/ml, respectively. The sensitivity of only PANI electrodes was 2.6 ± 0.3 μA/ng/ml, which was relatively lower than AG-added PANI. This increase was due to the presence of glycan functional groups in AG molecules that supported the retention of activity of antibodies. In addition, enhanced electron transportation at AG–PANI film surface was observed due to formation of an electroactive polymer film of two different electroactive functions to contribute toward enhancement in the detection sensitivity.  相似文献   

4.
Novel nickel and copper oxide nanoparticle modified polyaniline (PANI) nanofibers (NiO/CuO/PANI) were fabricated and used as a non-enzymatic sensor for detecting glucose. PANI nanofibers were prepared through electrodeposition, whereas nickel and copper oxide nanoparticles were deposited on PANI nanofibers by electrodeposition and electrochemical oxidation in situ. The morphology and structure of NiO/CuO/PANI nanocomposites were characterized by field emission scanning electron microscopy (FE–SEM), X-ray diffraction (XRD), Raman spectroscopy, and Fourier transform infrared (FT–IR). The as-prepared NiO/CuO/PANI electrode was employed for non-enzymatic glucose detection in alkaline electrolyte and showed better electrocatalytic activity compared with the PANI, CuO/PANI, and NiO/PANI electrodes. Consequently, an amperometric electrode of glucose was achieved under 0.6 V versus Ag/AgCl with a wide linear range from 20 to 2500 μM (R2 = 0.9978) and a low detection limit of 2.0 μM (signal/noise [S/N] = 3). This electrode can effectively analyze glucose concentration in human serum samples, avoiding interference, and is a promising non-enzymatic glucose sensor due to its low overpotential, high sensitivity, good selectivity and stability, fast response, and low cost.  相似文献   

5.
Chitosan (CS)-polyaniline (PANI) hybrid conducting biopolymer film was obtained on indium-tin-oxide (ITO) electrode using electrochemical polymerization process. Fourier transform infrared (FT-IR) spectra of PANI-CS had showed covalent and hydrogen binding between PANI and CS molecules. Electrochemical impedance spectroscopy (EIS) measurements had showed low charge transfer resistance (R(CT)) of PANI-CS and PANI. Successive rabbit antibody (IgGs) immobilization on PANI-CS, CS and PANI matrixes surface were confirmed with FT-IR and EIS measurements. Ochratoxin-A (OTA) interaction with IgGs had increased R(CT) values and showed linear response up to 10 ng/mL OTA concentration in electrolyte. Relative change in R(CT) was higher in PANI-CS due to higher proportion of carboxylic and hydroxyl functionalities at PANI-CS matrix surfaces. The absolute sensitivity of PANI, CS, and PANI-CS were 16+/-6, 22+/-9 and 53+/-8 Omega mL/ng, respectively derived from slope of linear response up to 10 ng/mL with 1 ng/mL minimum detection limit.  相似文献   

6.
Shi X  Lu A  Cai J  Zhang L  Zhang H  Li J  Wang X 《Biomacromolecules》2012,13(8):2370-2378
In our previous work, supramolecular films composed of hydrophilic cellulose and hydrophobic polyaniline (PANI) dissolved in NaOH/urea aqueous solution at low temperature through rearrangement of hydrogen bonds have been constructed. To further understand the miscibility and processability of the complex solution, the dynamic rheological behaviors of the PANI/cellulose complex solution were investigated, for the first time, in the present work. Transmission electron microscope (TEM) results demonstrated that the inclusion complexes consisted of PANI and cellulose, existed in the aqueous solution, showing a good miscibility. Time-temperatures superposition (tTs) results indicated that the PANI/cellulose solution exhibited a homogeneous system, and the complex solution was more stable than the cellulose solution in the temperature range from 5 to 25 °C. Winter-Chambon theory was proved to be capable of describing the gelation behavior of the PANI/cellulose complex solution. The relaxation exponent at the gel point was calculated to be 0.74, lower than the cellulose solution, indicating strong interactions between PANI and cellulose chains. Relatively larger flow activation energy of the PANI/cellulose solution suggested the formation and rupture of linkages in "junction zones" during the gelation processes. Furthermore, PANI/cellulose gels could form at elevated temperature as a result of the physical cross-linking and chain entanglement, and it was a thermoirreversible process. Moreover, the PANI/cellulose solution remained a liquid state for a long time at the temperature range from 0 to 8 °C, which is important for the industry process.  相似文献   

7.
Commercial porous polypropylene membranes were chemically modified with polyaniline (PANI) using ammonium persulfate as the oxidizer. The influence of polymerization conditions on the membrane properties was studied by adsorption analysis and membrane permeability. The PANI-coated polypropylene (PANI/PP) membranes possessed high affinity toward the proteins, which can be immobilized onto the membrane surface through physical adsorption or covalent immobilization. The quantity of immobilized horseradish peroxidase (HRP) and its activity depended on the quantity and quality (oxidation level) of PANI. The storage conditions for PANI/PP membranes containing immobilized HRP were studied. HRP immobilized on the PANI/PP membrane was shown to retain 70% of its activity after 3-month storage at +5 degrees C, suggesting that this material can be used for practical application, such as in bioreactors as enzyme membranes.  相似文献   

8.
对比试剂的使用能够显著提升光学相干层析(OCT)的成像效果。聚苯胺(PANI)是一种有机导电聚合物,在近红外(NIR)区有着很强的光吸收。本文采用PANI对常见的OCT成像对比试剂--金纳米棒(GNRs)进行修饰,合成了PANI/GNRs核壳粒子,并对其OCT成像对比能力进行了研究。PANI/GNRs展现出良好的NIR光吸收特性;同时,PANI对GNRs的包裹也显著提升了金纳米结构的稳定性、降低了GNRs原有的毒性。选用离体猪肝组织作为检测样本,发现纳米材料使用能够显著提升OCT的成像效果。与未修饰的GNRs及PANI粒子相比,PANI/GNRs的OCT成像对比效果明显更好。因此,PANI包裹的GNRs核壳纳米材料有望成为一种低毒性且效果良好的OCT对比试剂用于生物组织成像。  相似文献   

9.
Dubey R  Dutta D  Shami TC  Rao KU 《Chirality》2011,23(4):320-325
Optically active polyaniline (PANI) salts were readily generated in solution via the enantioselective acid doping of neutral emeraldine base (EB) form of PANI with either (+) or (-)-2-pyrrolidone-5-carboxylic acid (PCA) in dimethylsulfoxide (DMSO) and dimethylformamide (DMF) solvents. Strong mirror imaged circular dichroism (CD) spectra were obtained for the deep green polymer solutions obtained with (+) or (-) PCA, suggesting that the acid doping is enantioselective, with one helical screw of the polymer chain being preferentially produced depending on the nature of enantiomer. It was observed that molar concentration of PCA as well as nature of solvent plays a very important role in the generation of optically active PANI. The generated optically active PANI did not show any loss of optical activity up to 200 h.  相似文献   

10.
Polyaniline (PANI) is considered as one of the most fascinating conductive polymers in fabricating enzyme-based biosensors. Nevertheless, to improve both sensitivity and stability of the PANI-modified biosensor has been and continues to be a technical challenge. In this study, we have electrochemically synthesized the PANI film on a platinum (Pt) electrode and then used this electrode to construct a horseradish peroxidase (HRP)-based biosensor for the detection of hydrogen peroxide (H(2)O(2)). The electrochemical and structural properties of electrodes were characterized with scanning electron microscopy (SEM), thermogravimetric analysis (TGA), Fourier-transform infrared (FTIR) spectrophotometer, and cyclic voltammetry (CV). It was interestingly found that the PANI film synthesized in the presence of bovine serum albumin (BSA) has provided the electrode with enhanced sensitivity and excellent stability. Our results suggested that the embedded BSA might serve as an initial template for aniline polymerization and stabilized the microstructure of the PANI film significantly. The constructed HRP/PANI(BSA)/Pt electrode also exhibited a fine linear correlation with H(2)O(2) concentration. This approach by implanted BSA was useful for improving the sensitivity and stability of PANI-modified biosensor.  相似文献   

11.
Micellar peroxidase-catalyzed synthesis of chiral polyaniline   总被引:1,自引:0,他引:1  
Micellar peroxidase-catalyzed synthesis of chiral polyaniline (PANI) in the presence of dodecylbenzenesulfonic acid (DBSA) was developed. The effect of DBSA concentration on the catalytic efficiency of horseradish and palm tree peroxidases was examined. Favorable conditions for the enzymatic synthesis of chiral PANI, determined by a multiple factors design, demonstrated that the PANIs with the highest chirality were produced in the presence of low concentrations of optically active camphorsulphonic acid (CSA). Unexpectedly, the chiral PANI was also synthesized in the absence of CSA in feed. The favorable conditions for the enzymatic production of chiral and conducting PANIs were shown to be different. The morphology of the chiral PANI particles was examined by transmission and scanning electron microscopies.  相似文献   

12.
A novel method based on covalent attachment of two enzymes, glucose oxidase (GOD) and horseradish peroxide (HRP), onto carboxylic-derived multiwalled carbon nanotubes (MWNTs) for the deposition of electroactive polyaniline (PANI) under ambient conditions is described. Ultraviolet-visible spectroscopy, Fourier-transform infrared (FTIR) spectroscopy, and transmission electron microscopy were used to characterize the assembling of bienzyme and the morphology of PANI|MWNTs. Under the bienzyme biocatalytic condition, a head-to-tail structure of PANI templated by MWNTs was formed. The voltammetric characteristics of the resulting biosensor were investigated by cyclic voltammetry in the presence of glucose. The current response of PANI was linearly related to glucose concentration between 0.05 and 12.0mM with a correlation coefficient of 0.994. The synergistic performance of bienzyme, highly efficient polymerization, and templated deposition provide a general platform for the synthesis of nanowires and nanocircuits, the construction of bioelectronic devices, and the design of novel biosensors.  相似文献   

13.
Polyacylonitrile fibers (PAN) surfaces were modified with chemical polymerization of conductive polyaniline (PANI) in the presence of potassium dichromate as an oxidizing agent. The effect of aniline concentration on the grafting efficiency and on the electrical surface resistance of PAN/PANI composite fibers was investigated. The surface resistance of the conductive composite fibers in this work was found to be between 8.0 and 0.5 kΩ/cm. As the amount of grafted PANI increased on the PAN fibers the electrical resistance of composite fibers decreased. The PAN/PANI composite fibers were characterized by SEM and FTIR studies. Composite PAN/PANI fibers were used for reversible immobilization of invertase. The immobilization efficiency and the activity of the immobilized invertase (from 1.0 mg/mL invertase solution at pH 5.5) were increased with increasing PANI contents of the composite fibers. The maximum amount of immobilized enzyme onto composite fibers containing 2.0% PANI was about 76.6 mg/g. The optimum pH for the free enzyme was observed at 5.0. On the other hand, immobilized invertase yielded a broad optimum pH profile between pH 5.0 and 7.0. Immobilized invertase exhibited 83% of its original activity even after two months storage at 4 °C while the free enzyme showed only 7% of its initial activity.  相似文献   

14.
A single polyaniline (PANI) nanowire-based biosensor was established to detect immunoglobulin G (IgG) and myoglobin (Myo), which is one of the cardiac biomarkers. The single PANI nanowires were fabricated via an electrochemical growth method, in which single nanowires were formed between a pair of patterned electrodes. The single PANI nanowires were functionalized with monoclonal antibodies (mAbs) of IgG or Myo via a surface immobilization method, using 1-ethyl-3-(3-dimethyaminopropyl) carbodiimide (EDC), and N-hydroxysuccinimde (NHS). The functionalization was then verified by Raman spectroscopy and fluorescence microscopy. The target proteins of IgG and Myo were detected by measuring the conductance change of functionalized single PANI nanowires owing to the capturing of target proteins by mAbs. The detection limit was found to be 3 ng/mL for IgG and 1.4 ng/mL for Myo. No response was observed when single nanowires were exposed to a non-specific protein, demonstrating excellent specificity to expected target detection. Together with the fast response time (a few seconds), high sensitivity, and good specificity, this single PANI nanowire-based biosensor shows great promise in the detection of cardiac markers and other proteins.  相似文献   

15.
Comparison of the stability of five plant peroxidases (horseradish, royal palm tree leaf, soybean, and cationic and anionic peanut peroxidases) was carried out under acidic conditions favorable for synthesis of polyelectrolyte complexes of polyaniline (PANI). It demonstrates that palm tree peroxidase has the highest stability. Using this peroxidase as a catalyst, the enzymatic synthesis of polyelectrolyte complexes of PANI and poly(2-acrylamido-3-methyl-1-propanesulfonic acid) (PAMPS) was developed. The template polymerization of aniline was carried out in aqueous buffer at pH 2.8. Varying the concentrations of aniline, PAMPS, and hydrogen peroxide as reagents, favorable conditions for production of PANI were determined. UV-vis-NIR absorption and EPR demonstrated that PAMPS and PANI formed the electroactive complex similar to PANI doped traditionally using low molecular weight sulfonic acids. The effect of pH on conformational variability of the complex was evaluated by UV-vis spectroscopy. Atomic force microscopy showed that a size of the particles of the PANI-PAMPS complexes varied between 10 and 25 nm, depending on a concentration of PAMPS in the complex. The dc conductivity of the complexes depends also on the content of PAMPS, the higher conductivity being for the complexes containing the lower content of the polymeric template.  相似文献   

16.
Electrochemical properties of composite films consisting of polyaniline/carboxydextran (PANI/carDEX) as a biofuel cell electrode platform were investigated. These composite films were formed on a planar gold surface through electropolymerization after a simple chemical modification of dextran with carboxyl groups. Cyclic voltammetry indicated that the composite films retained a redox activity in neutral pH environment. The PANI/carDEX composite films showed an electrocatalytic activity for the oxidation of ascorbic acid. The PANI/carDEX composite films also demonstrated an excellent electron-transfer mediating capability for the bioelectrocatalytic activation of glucose oxidase (GOx) toward the oxidation of glucose.  相似文献   

17.
The charge storage characteristics of a composite nanoarchitecture with a highly functional 3D morphology are reported. The electrodes are formed by the electropolymerization of aniline monomers into a nanometer‐thick polyaniline (PANI) film that conformally coats graphitic petals (GPs) grown by microwave plasma chemical vapor deposition (MPCVD) on conductive carbon cloth (CC). The hybrid CC/GPs/PANI electrodes yield results near the theoretical maximum capacitance for PANI of 2000 F g?1 (based on PANI mass) and a large area‐normalized specific capacitance of ≈2.6 F cm?2 (equivalent to a volumetric capacitance of ≈230 F cm?3) at a low current density of 1 A g?1 (based on PANI mass). The specific capacitances remain above 1200 F g?1 (based on PANI mass) for currents up to 100 A g?1 with correspondingly high area‐normalized values. The hybrid electrodes also exhibit a high rate capability with an energy density of 110 Wh kg?1 and a maximum power density of 265 kW kg?1 at a current density of 100 A g?1. Long‐term cyclic stability is good (≈7% loss of initial capacitance after 2000 cycles), with coulombic efficiencies >99%. Moreover, prototype all‐solid‐state flexible supercapacitors fabricated from these hybrid electrodes exhibit excellent energy storage performance.  相似文献   

18.
A series of conductive composites cellulose–polyaniline (PANI) were heterogeneously synthesized by chemical oxidative polymerization of aniline with native cellulose activated by various acids. The chemical structure and morphology of the composites were examined by FT-IR analysis and TEM. TGA was used to study their thermal properties. The composites prepared using the di-basic acids exhibited more favorable conductivity than the composites prepared using the monobasic acids. The content of PANI increased with increasing of activation time, and while the conductivity decreased because of the aggregation of PANI particles at the activation time range from 50 to 120 min. Both the PANI content and the electrical conductivity increased with an increase of the amount of aniline, and reached the maximum values at the 0.5 g aniline, respectively. The acids were able to successfully activate cellulose and lead to the improvement of the accessibility and reactivity of the O–H groups. The composites were highly stable compared to pure cellulose due to the safeguard from PANI slices. This work provided a facile method for the synthesis of cellulose–polyaniline conductive composites with excellent conductivity.  相似文献   

19.
Li C  Zhang L  Ding L  Ren H  Cui H 《Biosensors & bioelectronics》2011,26(10):4169-4176
Conductive polymer, one of the most attractive electrode materials, has been applied to coat anode of MFC to improve its performance recently. In this paper, two conductive polymer materials, polyaniline (PANI) and poly(aniline-co-o-aminophenol) (PAOA) were used to modify carbon felt anode and physical and chemical properties of the modified anodes were studied. The power output and biodiversity of modified anodes, along with unmodified carbon anode were compared in two-chamber MFCs. Results showed that the maximum power density of PANI and PAOA MFC could reach 27.4 mW/m(2) and 23.8 mW/m(2), comparing with unmodified MFC, increased by 35% and 18% separately. Low temperature caused greatly decrease of the maximum voltage by 70% and reduced the sorts of bacteria on anodes in the three MFCs. Anode biofilm analysis showed different bacteria enrichment: a larger mount of bacteria and higher biodiversity were found on the two modified anodes than on the unmodified one. For PANI anode, the two predominant bacteria were phylogenetically closely related to Hippea maritima and an uncultured clone MEC_Bicarb_Ac-008; for PAOA, Clostridiales showed more enrichment. Compare PAOA with PANI, the former introduced phenolic hydroxyl group by copolymerization o-aminophenol with aniline, which led to a different microbial community and the mechanism of group effect was proposed.  相似文献   

20.
A novel method to indicate the degree of chirality in polyaniline (PANI) was developed. The ( d ‐camphorsulfonic acid)‐ and (HCl)‐PANI‐based electrodes exhibited significantly different electrochemical performances in d ‐ and l ‐Alanine (Ala) aqueous solution, respectively, which can be used for the characterization the optical activity of chiral PANI. Cyclic voltammogram, tafel, and open circuit potential of PANI‐based electrodes were measured within d ‐ and l ‐Ala electrolyte solution, respectively. The open circuit potentials under different reacting conditions were analyzed by Doblhofer model formula, in which [C+]poly1/[C+]poly2 was used as a parameter to characterize the degree of chirality in chiral PANI. The results showed that [C+]poly1/[C+]poly2 can be increased with increasing concentrations of (1S)‐(+)‐ and (1R)‐(?)‐10‐camphorsulfonic acid. In addition, we detected that appropriate response time and lower temperature are necessary to improve the degree of chirality. Chirality 25:39‐42, 2013.© 2012 Wiley Periodicals, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号