首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
DNA amplification using Polymerase Chain Reaction (PCR) in a small volume is used in Lab-on-a-chip systems involving DNA manipulation. For few microliters of volume of liquid, it becomes difficult to measure and monitor the thermal profile accurately and reproducibly, which is an essential requirement for successful amplification. Conventional temperature sensors are either not biocompatible or too large and hence positioned away from the liquid leading to calibration errors. In this work we present a fluorescence based detection technique that is completely biocompatible and measures directly the liquid temperature. PCR is demonstrated in a 3 muL silicon-glass microfabricated device using non-contact induction heating whose temperature is controlled using fluorescence feedback from SYBR green I dye molecules intercalated within sensor DNA. The performance is compared with temperature feedback using a thermocouple sensor. Melting curve followed by gel electrophoresis is used to confirm product specificity after the PCR cycles.  相似文献   

2.
We examined PCR in silicon dioxide-coated silicon-glass chips (12 microl in volume with a surface to volume ratio of approximately 17.5 mm(2)/microl) using two PCR reagent systems: (i) the conventional reagent system using Taq DNA polymerase; (ii) the hot-start reagent system based on a mixture of TaqStart antibody and Taq DNA polymerase. Quantitative results obtained from capillary electrophoresis for the expected amplification products showed that amplification in microchips was reproducible (between batch coefficient of variation 7.71%) and provided excellent yields. We also used the chip for PCR directly from isolated intact human lymphocytes. The amplification results were comparable with those obtained using extracted human genomic DNA. This investigation is fundamental to the integration of sample preparation, polynucleotide amplification and amplicate detection on a microchip.  相似文献   

3.
We present a new approach for real-time monitoring of PCR amplification of a specific sequence from the human c-MYC proto-oncogene using a Ta(2)O(5) electrolyte-insulator-semiconductor (EIS) sensor. The response of the fabricated EIS sensor to cycle DNA amplification was evaluated and compared to standard SYBR-green fluorescence incorporation, showing it was possible to detect DNA concentration variations with 30 mV/μM sensitivity. The sensor's response was then optimized to follow in real-time the PCR amplification of c-MYC sequence from a genomic DNA sample attaining an amplification profile comparable to that of a standard real-time PCR. Owing to the small size, ease of fabrication and low-cost, the developed Ta(2)O(5) sensor may be incorporated onto a microfluidic device and then used for real-time PCR. Our approach may circumvent the practical and economical obstacles posed by current platforms that require an external fluorescence detector difficult to miniaturize and incorporate into a lab-on-chip system.  相似文献   

4.
Nucleic acid amplification has long been used in biosensor technologies, such as DNA sensors, DNA chips and microarrays, due to its advantage of high sensitivity in detecting target DNA. However, dynamic monitoring of nucleic acid amplifications with traditional DNA sensors in real-time is difficult since a constant temperature must be maintained during detection. Thus, the piezoelectric sensor, one type of traditional DNA sensor, is not applicable in real-time monitoring PCR due to the dramatic change in temperature that occurs during reaction. In this study, we introduced strand displacement amplification (SDA), an well-developed nucleic acid amplification technique that can work under conditions of constant temperature, into the development of a novel piezoelectric sensor. Using the new SDA-piezoelectric DNA sensor, we designed a stable system for liquid-phase detection, in which the crystal oscillator plate was fixed by an easily adjustable screw-threaded clamping mechanism and successfully applied the new sensor system to real-time SDA monitoring of human cytomegalovirus (HCMV). This new technique overcomes the shortcomings of traditional DNA sensors in real-time monitoring of nucleic acid amplification. The technique has proved to be a markedly simplified procedure with a number of advantages, such as higher sensitivity, better time efficiency, and the ability of dynamic real-time detection.  相似文献   

5.
丹参ISSR-PCR反应体系的建立与正交优化   总被引:4,自引:0,他引:4  
李嵘  王喆之 《广西植物》2008,28(5):599-603
利用正交试验设计的方法,从引物浓度、Taq DNA聚合酶浓度、Mg2+浓度、dNTP浓度4种因素3个水平,对丹参ISSR-PCR反应体系进行优化分析,并在此基础上对模板DNA浓度、PCR反应过程中的退火温度进行梯度检测。结果表明:20μL ISSR-PCR反应体系中各因素的最佳浓度为1×PCR buffer、200μmol/L dNTP、1.0μmol/L引物、1.5mmol/L Mg2+和1 U Taq DNA聚合酶,最佳模板DNA浓度为20~60ng,引物UBC 835的最佳退火温度为51.7℃。  相似文献   

6.
This paper presents a micro polymerase chain reaction (PCR) chip for the DNA-based diagnosis of microorganism genes and the detection of their corresponding antibiotic-resistant genes. The micro PCR chip comprises cheap biocompatible soda-lime glass substrates with integrated thin-film platinum resistors as heating/sensing elements, and is fabricated using micro-electro-mechanical-system (MEMS) techniques in a reliable batch-fabrication process. The heating and temperature sensing elements are made of the same material and are located inside the reaction chamber in order to ensure a uniform temperature distribution. This study performs the detection of several genes associated with upper respiratory tract infection microorganisms, i.e. Streptococcus pneumoniae, Haemopilus influenze, Staphylococcu aureus, Streptococcus pyogenes, and Neisseria meningitides, together with their corresponding antibiotic-resistant genes. The lower thermal inertia of the proposed micro PCR chip relative to conventional bench-top PCR systems enables a more rapid detection operation with reduced sample and reagent consumption. The experimental data reveal that the high heating and cooling rates of the system (20 and 10 degrees C/s, respectively) permit successful DNA amplification within 15 min. The micro PCR chip is also capable of performing multiple DNA amplification, i.e. the simultaneous duplication of multiple genes under different conditions in separate reaction wells. Compared with the large-scale PCR system, it is greatly advantageous for fast diagnosis of multiple infectious diseases. Multiplex PCR amplification of two DNA segments in the same well is also feasible using the proposed micro device. The developed micro PCR chip provides a crucial tool for genetic analysis, molecular biology, infectious disease detection, and many other biomedical applications.  相似文献   

7.
A temperature sensor array chip was developed to monitor the thermal cycling profiles of a polymerase chain reaction (PCR). DNA amplification efficiency of each cycle was estimated through temperature data to fit the stochastic model. A fluorescence detector system was constructed to detect the PCR amplifications of latter cycles, at which the fluorescence intensity passed the optical detection threshold. Through monitoring of both temperature and fluorescence, DNA amplification efficiency curve was completed for quantification. The F?rster resonance energy transfer (FRET) was employed to detect the measurements of the PCR product amount at the reaction endpoint. The chip-based, real-time PCR machine was constructed to perform the amplification efficiency curve-based quantification method. This novel method achieved the absolute quantification of the Hepatitis B virus (HBV) DNA using a single sample without the construction of the standard curve. The coefficient of variation (CV) of the 15 replicates inter assay experiments was less than 5.87%. Compared with the CV values obtained from the commercial machine in the range of 4.33-14.56%, it is noted that CV values of the prototype with respect to the samples of different initial concentration ranging from 10(7) to 10(3)copies/ml are almost equable.  相似文献   

8.
PCR amplification of DNA fragments has been routinely used in gene cloning and engineering of microbial strains for biotechnological purposes such as production of biofuels and green chemicals. However, it is often a challenge to amplify large DNA fragments (>5 kb) from low GC microorganisms using the standard PCR protocols. In this brief communication, we report a modified PCR method with an extension temperature of 60°C, which efficiently amplified a 5.3 and a 5.5 kb DNA fragment (an extension time of 6 min) from a low GC bacterium Clostridium acetobutylicum (~30% GC). A lower than normal extension temperature (72°C) approach may also facilitate PCR amplification of large DNA fragments (>5 kb) from other low GC microorganisms.  相似文献   

9.
A theoretical framework for prediction of the dynamic evolution of chemical species in DNA amplification reactions, for any specified sequence and operating conditions, is reported. Using the polymerase chain reaction (PCR) as an example, we developed a sequence- and temperature-dependent kinetic model for DNA amplification using first-principles biophysical modeling of DNA hybridization and polymerization. We compare this kinetic model with prior PCR models and discuss the features of our model that are essential for quantitative prediction of DNA amplification efficiency for arbitrary sequences and operating conditions. Using this model, the kinetics of PCR is analyzed. The ability of the model to distinguish between the dynamic evolution of distinct DNA sequences in DNA amplification reactions is demonstrated. The kinetic model is solved for a typical PCR temperature protocol to motivate the need for optimization of the dynamic operating conditions of DNA amplification reactions. It is shown that amplification efficiency is affected by dynamic processes that are not accurately represented in the simplified models of DNA amplification that form the basis of conventional temperature cycling protocols. Based on this analysis, a modified temperature protocol that improves PCR efficiency is suggested. Use of this sequence-dependent kinetic model in a control theoretic framework to determine the optimal dynamic operating conditions of DNA amplification reactions, for any specified amplification objective, is discussed.  相似文献   

10.
A theoretical framework for prediction of the dynamic evolution of chemical species in DNA amplification reactions, for any specified sequence and operating conditions, is reported. Using the polymerase chain reaction (PCR) as an example, we developed a sequence- and temperature-dependent kinetic model for DNA amplification using first-principles biophysical modeling of DNA hybridization and polymerization. We compare this kinetic model with prior PCR models and discuss the features of our model that are essential for quantitative prediction of DNA amplification efficiency for arbitrary sequences and operating conditions. Using this model, the kinetics of PCR is analyzed. The ability of the model to distinguish between the dynamic evolution of distinct DNA sequences in DNA amplification reactions is demonstrated. The kinetic model is solved for a typical PCR temperature protocol to motivate the need for optimization of the dynamic operating conditions of DNA amplification reactions. It is shown that amplification efficiency is affected by dynamic processes that are not accurately represented in the simplified models of DNA amplification that form the basis of conventional temperature cycling protocols. Based on this analysis, a modified temperature protocol that improves PCR efficiency is suggested. Use of this sequence-dependent kinetic model in a control theoretic framework to determine the optimal dynamic operating conditions of DNA amplification reactions, for any specified amplification objective, is discussed.  相似文献   

11.
以多倍体罗汉果DNA为材料,采用L16(4~5)正交组合试验和单因素梯度试验,研究Mg~(2+)、dNTP、引物、Taq DNA聚合酶、模板DNA浓度和退火温度、循环次数等对PCR扩增结果以及内切酶量、酶切时间对酶切反应的影响。结果表明,多倍体罗汉果RFLP最优PCR反应体系和扩增参数为:在25μL扩增反应体系中,10×Buffer 2.5μL,MgCl_2 1.5 mmol/L,dNTP 0.2 mmol/L,引物0.1μmol/L,Taq DNA聚合酶2.0 U,模板DNA 60 ng;退火温度为56℃,循环次数为35次。酶切反应体系:内切酶10×Buffer 2.0μL,内切酶5.0U,PCR产物15μL,超纯水补至20μL;酶切时间2 h。  相似文献   

12.
We show that using low denaturation temperatures (80–88°C) during ligation mediated PCR (LM PCR) of bacterial DNA leads to the amplification of limited sets of the less stable DNA fragments. A set of electrophoretic patterns of such fragments obtained at different denaturation temperatures forms the PCR melting profile (PCR MP). A single pattern obtained for a given temperature and a set of patterns arising after application of several denaturation temperatures (PCR MP) are very specific for the given bacterial genome and may be used for strain characterisation and differentiation. The method may also be used for amplification and isolation of the less stable DNA fragments in a genome.  相似文献   

13.
Recent development of the long PCR technology has provided an invaluable tool in many areas of molecular biology. However, long PCR amplification fails whenever the DNA template is imperfectly preserved. We report that Escherichia coli exonuclease III, a major repair enzyme in bacteria, strikingly improves the long PCR amplification of damaged DNA templates. Escherichia coli exonuclease III permitted or improved long PCR amplification with DNA samples submitted to different in vitro treatments known to induce DNA strand breaks and/or apurinic/apyrimidinic (AP) sites, including high temperature (99°C), depurination at low pH and near-UV radiation. Exonuclease III also permitted or improved amplification with DNA samples that had been isolated several years ago by the phenol/chloroform method. Amelioration of long PCR amplification was achieved for PCR products ranging in size from 5 to 15.4 kb and with DNA target sequences located either within mitochondrial DNA or the nuclear genome. Exonuclease III increased the amplification of damaged templates using either rTth DNA polymerase alone or rTth plus Vent DNA polymerases or Taq plus Pwo DNA polymerases. However, exonuclease III could not improve PCR amplification from extensively damaged DNA samples. In conclusion, supplementation of long PCR mixes with E.coli exonuclease III may represent a major technical advance whenever DNA samples have been partly damaged during isolation or subsequent storage.  相似文献   

14.

Background

In general, the image analysis of nucleic acid for detecting DNA is dependent on the gel documentation system. These experiments may deal with harmful staining agents and are time consuming. To address these issues, real-time polymerase chain reaction (PCR) devices have been developed. The advantages of real-time PCR are its capabilities for real-time diagnosis, improved sensitivity, and digitization of measurement results. However, real-time PCR equipment is still too bulky and expensive for use in small hospitals and laboratories.

Methods

This paper describes an evaluation-independent real-time PCR system that differs from conventional systems in that it uses a side-illumination optical detection system and a temperature adjustment coefficient for DNA detection. The overall configuration of the evaluation-independent system includes the PCR chip and system hardware and software. The use of the side-illumination method for detection enables the system size to be reduced compared to systems using a typical illumination method. Furthermore, the results of a PCR test are strongly affected by the reaction temperature. Thus, extremely precise control of the temperature of the reaction is needed to obtain accurate results and good reliability. We derived a temperature compensation coefficient that allows us to compensate for the differences between the measured temperature of the negative temperature coefficient (NTC) thermistor sensor and the real temperature of the thermocouple.

Results

Applying the temperature compensation coefficient parameter using the NTC thermistor and using the side-illumination method resulted in an increase in the initial sensor value. The occurrence of the DNA section amplification decreased to 22 cycles from 24 cycles.

Conclusions

The proposed system showed comparable performance to that of an existing real-time PCR, even with the use of simpler and smaller optical devices.
  相似文献   

15.
Chou WP  Chen PH  Miao M  Kuo LS  Yeh SH  Chen PJ 《BioTechniques》2011,50(1):52-57
Herein we describe a simple platform for rapid DNA amplification using convection. Capillary convective PCR (CCPCR) heats the bottom of a capillary tube using a dry bath maintained at a fixed temperature of 95°C. The tube is then cooled by the surrounding air, creating a temperature gradient in which a sample can undergo PCR amplification by natural convection through reagent circulation. We demonstrate that altering the melting temperature of the primers relative to the lowest temperature in the tube affects amplification efficiency; adjusting the denaturation temperature of the amplicon relative to the highest temperature in the tube affects maximum amplicon size, with amplicon lengths of ≤500 bp possible. Based on these criteria, we successfully amplified DNA sequences from three different viral genomes in 30 min using CCPCR, with a sensitivity of ~30 copies per reaction.  相似文献   

16.
Researchers face a significant problem in PCR amplification of DNA fragments with high GC contents. Analysis of these regions is of importance since many regulatory regions of different genes and their first exons are GC-rich. There are a large number of protocols for amplification of GC-rich DNA, some of which perform well but are costly. Most of the economical protocols fail to perform consistently, especially on products with >80 % GC contents and a size of >300 bp. One of these protocols requires multiple additions of DNA polymerase during thermal cycling which therefore rules out its utility if a large number of samples have to be amplified. We have established a method for simultaneous amplification of specific PCR products from a large number of human DNA samples using general laboratory reagents. These amplicons have GC contents ranging from 65–85 % and sizes up to 870 bp. The protocol uses a PCR buffer containing co-solvents including 2-mercaptoethanol and bovine serum albumin for amplification of DNA. A specific thermal cycling profile is also used which incorporates a high annealing temperature in the first 7 cycles of the reactions. The PCR products are suitable for different molecular biology applications including sequencing.  相似文献   

17.
Here we present a simple, highly efficient, universal automatic kinetics switch (AKS) gene synthesis method that enables synthesis of DNA up to 1.6 kbp from 1 nM oligonucleotide with just one polymerase chain reaction (PCR) process. This method eliminates the interference between the PCR assembly and amplification in one-step gene synthesis and simultaneously maximizes the amplification of emerged desired DNA by using a pair of flanked primers. In addition, we describe an analytical model of PCR gene synthesis based on the thermodynamics and kinetics of DNA hybridization. The kinetics difference between standard PCR amplification and one-step PCR gene synthesis is analyzed using this model and is validated using real-time gene synthesis with eight gene segments (318-1656 bp). The effects of oligonucleotide concentration, stringency of annealing temperature, annealing time, extension time, and PCR buffer conditions are examined systematically. Analysis of the experimental results leads to new insights into the gene synthesis process and aids in optimizing gene synthesis conditions. We further extend this method for multiplexing gene assembly with a total DNA length up to 5.74 kbp from 1 nM oligonucleotide.  相似文献   

18.
A conducting polymer sensor for direct label-free DNA detection based on a polythiophene bearing an electroactive linker group is investigated. DNA hybridization is studied by electrochemical impedance spectroscopy (EIS) and quartz crystal microbalance (QCM) techniques. Modelling of DNA hybridization by EIS measurements exhibits the contribution of nucleic acid to a superficial p-doping process. A 675-mer single-stranded DNA is produced using asymmetric PCR from a DNA sequence of a transposable element mariner and hybridized to the previously immobilized probe. Electrochemical stimulus leads to the release "on demand" of DNA fragments and the amount delivery permits to do PCR amplification.  相似文献   

19.
【目的】探讨适合DNA提取的天牛成虫标本保存方法。【方法】采用SDS-蛋白酶K消化法对液氮中冷冻保存、无水乙醇-20℃冷冻保存、无水乙醇室温保存和干标本室温保存且保存时间在2年以上的松墨天牛Monochamus alternates Hope成虫标本基因组DNA进行提取,并对不同保存方式提取的DNA样本进行了质量比较和分析。【结果】在上述常见的松墨天牛成虫标本4种保存方式中,以液氮中冷冻保存效果最佳,其次为无水乙醇-20℃冷冻保存,插针干标本室温保藏效果最差。利用昆虫线粒体基因CO I和CO II的通用引物从上述DNA中均能够成功扩增出目的片段,测序结果证实扩增片段符合预期。【结论】液氮和无水乙醇-20℃冷冻保存适合松墨天牛成虫标本长期保存,且不影响后续的PCR扩增和测序。  相似文献   

20.
Since its discovery, the polymerase chain reaction (PCR) has been used for different purposes in the field of DNA research. We tested the PCR for the diagnosis of HTLV-I/-II infections. PCR was used to amplify 141- and 149-base pair regions from the HTLV-I and HTLV-II virus genomes, respectively. The annealing temperature in the PCR amplification was optimized using 20% polyacrylamide gels and silver staining. Even a slight change (3 degrees C) in the annealing temperature had an effect on the specificity of the reaction. The PCR products were detected with biotin and Eu-labeled oligonucleotide probes in a solution hybridization format. The linearity of the assay was tested with serial dilutions of purified chromosomal DNA containing integrated HTLV-II sequences. The linearity was found to be dependent on the number of cycles used in the PCR amplification. The best linearity, at a target level of a few copies, was achieved using a low number of cycles. The specificity of the assay was tested using HTLV-I and HTLV-II-infected lymphocytes from the cell lines Hut102 and MO480, respectively. No cross reactivity between these analytes was observed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号