首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
This study evaluated the setup uncertainties for brain sites when using BrainLAB’s ExacTrac X-ray 6D system for daily pretreatment to determine the optimal planning target volume (PTV) margin. Between August 2012 and April 2015, 28 patients with brain tumors were treated by daily image-guided radiotherapy using the BrainLAB ExacTrac 6D image guidance system of the Novalis-Tx linear accelerator. DUONTM (Orfit Industries, Wijnegem, Belgium) masks were used to fix the head. The radiotherapy was fractionated into 27–33 treatments. In total, 844 image verifications were performed for 28 patients and used for the analysis. The setup corrections along with the systematic and random errors were analyzed for six degrees of freedom in the translational (lateral, longitudinal, and vertical) and rotational (pitch, roll, and yaw) dimensions. Optimal PTV margins were calculated based on van Herk et al.’s [margin recipe = 2.5∑ + 0.7σ - 3 mm] and Stroom et al.’s [margin recipe = 2∑ + 0.7σ] formulas. The systematic errors (∑) were 0.72, 1.57, and 0.97 mm in the lateral, longitudinal, and vertical translational dimensions, respectively, and 0.72°, 0.87°, and 0.83° in the pitch, roll, and yaw rotational dimensions, respectively. The random errors (σ) were 0.31, 0.46, and 0.54 mm in the lateral, longitudinal, and vertical rotational dimensions, respectively, and 0.28°, 0.24°, and 0.31° in the pitch, roll, and yaw rotational dimensions, respectively. According to van Herk et al.’s and Stroom et al.’s recipes, the recommended lateral PTV margins were 0.97 and 1.66 mm, respectively; the longitudinal margins were 1.26 and 3.47 mm, respectively; and the vertical margins were 0.21 and 2.31 mm, respectively. Therefore, daily setup verifications using the BrainLAB ExacTrac 6D image guide system are very useful for evaluating the setup uncertainties and determining the setup margin.  相似文献   

2.
BackgroundThe purpose of this study was to investigate the feasibility of MOSFET dosimeter in measuring eye dose during 2D MV portal imaging for setup verification in radiotherapy.Materials and methodsThe in-vivo dose measurements were performed by placing the dosimeters over the eyes of 30 brain patients during the acquisition of portal images in linear accelerator by delivering 1 MU with the field sizes of 10 × 10 cm2 and 15 × 15 cm2.ResultsThe mean doses received by the left and right eyes of 10 out of 30 patients when both eyes were completely inside the anterior portal field were found to be 2.56 ± 0.2 cGy and 2.75 ± 0.2, respectively. Similarly, for next 10 patients out of the same 30 patients the mean doses to left and right eyes when both eyes were completely out of the anterior portal fields were found to be 0.13 ± 0.02 cGy and 0.17 ± 0.02 cGy, respectively. The mean doses to ipsilateral and contralateral eye for the last 10 patients when one eye was inside the anterior portal field were found to be 3.28 ± 0.2 cGy and 0.36 ± 0.1 cGy, respectively.ConclusionThe promising results obtained during 2D MV portal imaging using MOSFET have shown that this dosimeter is well suitable for assessing low doses during imaging thereby enabling to optimize the imaging procedure using the dosimetric data obtained. In addition, the documentation of the dose received by the patient during imaging procedure is possible with the help of an in-built software in conjunction with the MOSFET reader module.  相似文献   

3.
ObjectiveWe retrospectively analyzed our experience with time-staged gamma knife stereotactic radiosurgery (GKS) in treating large arteriovenous malformation(AVM)s;≥ 10 cm3).MethodsForty-five patients who underwent time-staged GKS (2-stage, n = 37;3-stage,n = 8) between March 1998 and December 2011 were included. The mean volume treated was 20.42±6.29 cm3 (range, 10.20–38.50 cm3). Obliteration rates of AVMs and the associated complications after GKS were evaluated.ResultsMean AVM volume (and median marginal dose) at each GKS session in the 37 patients who underwent 2-stage GKS was 19.67±6.08 cm3 (13 Gy) at session 1 and 6.97±6.92 cm3 (17 Gy) at session 2. The median interval period was 39 months. After follow-up period of 37 months, the complete obliteration rate was 64.9%. The mean AVM volume (and median marginal dose) at each GKS session in the 8 patients who underwent 3-stage GKS was 23.90±6.50 cm3 (12.25 Gy), 19.43±7.46 cm3 (13.5 Gy), 7.48±6.86 cm3 (15.5 Gy) at session 1, 2, and 3, respectively. The median interval duration between each GKS session was 37.5 and 38 months, respectively. After a median follow-up period of 47.5 months, 5 patients (62.5%) achieved complete obliteration. Postradiosurgical hemorrhage developed in 5 patients (11.1%) including one case of major bleeding and 4 cases of minor bleeding. No patient suffered from clinically symptomatic radiation necrosis following radiation.ConclusionTime-staged GKS could be an effective and safe treatment option in the management of large AVMs.  相似文献   

4.

Objectives

Cardiovascular magnetic resonance feature tracking (CMR-FT) offers quantification of myocardial deformation from routine cine images. However, data using CMR-FT to quantify left ventricular (LV) torsion and diastolic recoil are not yet available. We therefore sought to evaluate the feasibility and reproducibility of CMR-FT to quantify LV torsion and peak recoil rate using an optimal anatomical approach.

Methods

Short-axis cine stacks were acquired at rest and during dobutamine stimulation (10 and 20 µg·kg−1·min−1) in 10 healthy volunteers. Rotational displacement was analysed for all slices. A complete 3D-LV rotational model was developed using linear interpolation between adjacent slices. Torsion was defined as the difference between apical and basal rotation, divided by slice distance. Depending on the distance between the most apical (defined as 0% LV distance) and basal (defined as 100% LV distance) slices, four different models for the calculation of torsion were examined: Model-1 (25–75%), Model-2 (0–100%), Model-3 (25–100%) and Model-4 (0–75%). Analysis included subendocardial, subepicardial and global torsion and recoil rate (mean of subendocardial and subepicardial values).

Results

Quantification of torsion and recoil rate was feasible in all subjects. There was no significant difference between the different models at rest. However, only Model-1 (25–75%) discriminated between rest and stress (Global Torsion: 2.7±1.5°cm−1, 3.6±2.0°cm−1, 5.1±2.2°cm−1, p<0.01; Global Recoil Rate: −30.1±11.1°cm−1s−1,−46.9±15.0°cm−1s−1,−68.9±32.3°cm−1s−1, p<0.01; for rest, 10 and 20 µg·kg−1·min−1 of dobutamine, respectively). Reproducibility was sufficient for all parameters as determined by Bland-Altman analysis, intraclass correlation coefficients and coefficient of variation.

Conclusions

CMR-FT based derivation of myocardial torsion and recoil rate is feasible and reproducible at rest and with dobutamine stress. Using an optimal anatomical approach measuring rotation at 25% and 75% apical and basal LV locations allows effective quantification of torsion and recoil dynamics. Application of these new measures of deformation by CMR-FT should next be explored in disease states.  相似文献   

5.
α-Amylase produced by Bacillus licheniformis CUMC305 was purified 212-fold with a 42% yield through a series of four steps. The purified enzyme was homogeneous as shown by sodium dodecyl sulfate-polyacrylamide gel electrophoresis and discontinuous gel electrophoresis. The purified enzyme showed maximal activity at 90°C and pH 9.0, and 91% of this activity remained at 100°C. The enzyme retained 91, 79, and 71% maximal activity after 3 h of treatment at 60°C, 3 h at 70°C, and 90 min at 80°C, respectively, in the absence of substrate. On the contrary, in the presence of substrate (soluble starch), the α-amylase enzyme was fully stable after a 4-h incubation at 100°C. The enzyme showed 100% stability in the pH range 7 to 9; 95% stability at pH 10; and 84, 74, 68, and 50% stability at pH values of 6, 5, 4, and 3, respectively, after 18 h of treatment. The activation energy for this enzyme was calculated as 5.1 × 105 J/mol. The molecular weight was estimated to be 28,000 by sodium dodecyl sulfate-gel electrophoresis. The relative rates of hydrolysis of soluble starch, amylose, amylopectin, and glycogen were 1.27, 1.8, 1.94, and 2.28 mg/ml, respectively. Vmax values for hydrolysis of these substrates were calculated as 0.738, 1.08, 0.8, and 0.5 mg of maltose/ml per min, respectively. Of the cations, Na+, Ca2+, and Mg2+, showed stimulatory effect, whereas Hg2+, Cu2+, Ni2+, Zn2+, Ag+, Fe2+, Co2+, Cd2+, Al3+, and Mn2+ were inhibitory. Of the anions, azide, F, SO32−, SO43−, S2O32−, MoO42−, and Wo42− showed an excitant effect. p-Chloromercuribenzoic acid and sodium iodoacetate were inhibitory, whereas cysteine, reduced glutathione, thiourea, β-mercaptoethanol, and sodium glycerophosphate afforded protection to enzyme activity. α-Amylase was fairly resistant to EDTA treatment at 30°C, but heating at 90°C in presence of EDTA resulted in the complete loss of enzyme activity, which could be recovered partially by the addition of Cu2+ and Fe2+ but not by the addition of Ca2+ or any other divalent ions.  相似文献   

6.
Rates of sulfate reduction (SR) and anaerobic oxidation of methane (AOM) in hydrothermal deep-sea sediments from Guaymas Basin were measured at temperatures of 5 to 200°C and pressures of 1 × 105, 2.2 × 107, and 4.5 × 107 Pa. A maximum SR of several micromoles per cubic centimeter per day was found at between 60 and 95°C and 2.2 × 107 and 4.5 × 107 Pa. Maximal AOM was observed at 35 to 90°C but generally accounted for less than 5% of SR.  相似文献   

7.

Background

The aim of the modern radiotherapy is to get a homogenous dose distribution in PTV, which is obtained by using for example physical or dynamic wedges. The using of a physical wedge has provided such isodose distributions but their use resulted in detrimental dosimetric consequences, for example beam hardening effects and practical consequences of filter handling or possible misalignment. Linear accelerators are now equipped with collimator jaws systems and controlled by modern computers and it is possible to generate wedge shaped isodose distributions dynamically. Because of a more comfortable use of a dynamic wedge, there are alternatives to the standard physical wedge. During the treatment, different segments of the treatment field can be exposed to the primary beam at different intervals of time. This process of shrinking the field while modulating the collimator jaw velocity and dose rate creates the desired wedge-shaped isodose gradient across the treatment field. Dynamic wedges can replace physical wedges but they need more precise dosimetry and quality control procedures.

Aim

The aim of this study was to perform a multienergetic verification of dynamic wedge angles using the multichannel detector PTW LA48 linear array.

Material and methods

The measurements of angle value of dynamic wedges were performed for Clinac 2300 C/D accelerators (Varian). The accelerator was equipped with the EDW option for 6 MV and 15 MV photon beams. In this case, 7 wedge angle values were used: 10°, 15°, 20°, 25°, 30°, 45° and 60°. The dynamic wedges are realized by continuous movement of one collimator jaw. The field size is gradually reduced until the collimator is almost completely closed or the field increases, while the beam is on. The measurements were divided in two steps: in the first step, the dynamic wedges were verified with the recommended values and in the second step there the planned and measured angles of dynamic wedges were compared. Measurements were made by means of LA48 linear array of ionization chambers (PTW). The results of the measurements were compared with the reference profile produced by the treatment planning system ECLIPSE 8.5 (Varian).

Results

The results showed differences between measured and calculated angle of dynamic wedges. The differences were observed for both energies in the case of a small angle value. For energies 6 MV and 15 MV, almost all percentage difference between the measured and calculated profile was lower than 5%. The biggest difference was observed in the first step of measurements when the angle of Dynamic Wedge was verified. The comparison between the planned and measured angle value of Dynamic Wedge showed the difference between 0.1% and 4.5%.The difference for 6 MV for the angle value of 10° in orientation IN was 1.1% and for energy 15 MV in the same case the difference was 3.8%. Thinner wedges exhibit less difference.

Conclusion

It is necessary to provide comprehensive quality control procedure for enhanced dynamic wedges. Verification measurements should be an obligatory procedure in the recommendation for the testing of medical accelerators. These results are the preliminary results to provide measurements in other Polish Cancer Centres.  相似文献   

8.
The study investigates the effects of the 11+ and HarmoKnee injury prevention programmes on knee strength in male soccer players. Under-21-year-old players (n=36) were divided equally into: the 11+, HarmoKnee and control groups. The programmes were performed for 24 sessions (20-25 min each). The hamstrings and quadriceps strength were measured bilaterally at 60°·s-1, 180°·s-1 and 300°·s-1. The concentric quadriceps peak torque (PT) of the 11+ increased by 27.7% at 300°·s-1 in the dominant leg (p<0.05). The concentric quadriceps PT of HarmoKnee increased by 36.6%, 36.2% and 28% in the dominant leg, and by 31.3%, 31.7% and 20.05% at 60°·s-1, 180°·s-1 and 300°·s-1 in the non-dominant leg respectively. In the 11+ group the concentric hamstring PT increased by 22%, 21.4% and 22.1% at 60°·s-1, 180°·s-1 and 300°·s-1, respectively in the dominant leg, and by 22.3%, and 15.7% at 60°·s-1 and 180°·s-1, in the non-dominant leg. In the HarmoKnee group the hamstrings in the dominant leg showed an increase in PT by 32.5%, 31.3% and 14.3% at 60°·s-1, 180°·s-1 and 300°·s-1, and in the non-dominant leg hamstrings PT increased by 21.1% and 19.3% at 60°·s-1 and 180°·s-1 respectively. The concentric hamstrings strength was significantly different between the 11+ and control groups in the dominant (p=0.01) and non-dominant legs (p=0.02). The HarmoKnee programme enhanced the concentric strength of quadriceps. The 11+ and HarmoKnee programmes are useful warm-up protocols for improving concentric hamstring strength in young professional male soccer players. The 11+ programme is more advantageous for its greater concentric hamstring strength improvement compared to the HarmoKnee programme.  相似文献   

9.

Introduction

Exact knowledge of femoral neck inclination and torsion angles is important in recognizing, understanding and treating pathologic conditions in the hip joint. However, published results vary widely between different studies, which indicates that there are persistent difficulties in carrying out exact measurements.

Methods

A three dimensional modeling and analytical technology was used for the analysis of 1070 CT datasets of skeletally mature femurs. Individual femoral neck angles and torsion angles were precisely computed, in order to establish whether gender, age, body mass index and ethnicity influence femoral neck angles and torsion angles.

Results

The median femoral neck angle was 122.2° (range 100.1–146.2°, IQR 117.9–125.6°). There are significant gender (female 123.0° vs. male 121.5°; p = 0.007) and ethnic (Asian 123.2° vs. Caucasian 121.9°; p = 0.0009) differences. The median femoral torsion angle was 14.2° (-23.6–48.7°, IQR 7.4–20.4°). There are significant gender differences (female 16.4° vs. male 12.1°; p = 0.0001). Femoral retroversion was found in 7.8% of the subjects.

Conclusion

Precise femoral neck and torsion angles were obtained in over one thousand cases. Systematic deviations in measurement due to human error were eliminated by using automated high accuracy morphometric analysis. Small but significant gender and ethnic differences were found in femoral neck and torsion angles.  相似文献   

10.
1. Sedimentation-velocity, intrinsic-viscosity and partial-specific-volume measurements on a typical blood-group-specific glycoprotein are reported for a range of environmental conditions. 2. The sedimentation coefficients, S, are strongly concentration-dependent, and follow the reciprocal law; the limiting values at 2°, 25° and 45°, after correction to 25°, show slight dependence on temperature. 3. The intrinsic viscosities, [η], at 25° and 45° show more marked temperature-dependence, and correspond to a very asymmetric or very expanded molecular conformation. 4. From the value of the ratio K/[η], where K=S0.d(1/S)/dc, it is concluded that the molecular conformation is roughly spherical; application of the Einstein viscosity equation then suggests an expansion factor of about 60, compatible with a flexible configuration approaching that of a random coil. 5. The sedimentation coefficient is not affected by variation of ionic strength in the range 0·01–0·50, nor by pH in the range 3–10. 6. Sodium dodecyl sulphate at 1·5% produces a small decrease in S; the effect is greater than would be expected from the observed extent of binding, but is too small to correspond to a significant change in secondary structure; the serological activity is unaffected by sodium dodecyl sulphate. 7. All the properties observed indicate the absence of any secondary structure in blood-group substances.  相似文献   

11.
PurposeIntra-Operative Electron Radiation Therapy (IOERT) is used to treat rectal cancer at our institution, and in vivo measurements with Gafchromic EBT3® films were introduced as quality assurance. The purpose of this work was to quantify the uncertainties associated with digitization of very small EBT3 films irradiated simultaneously, in order to optimize in vivo dosimetry for IOERT.MethodsFilm samples of different sizes - M1 (5×5cm2), M2 (1.5×1.5 cm2), M3 (1.0×1.5 cm2) and M4 (0.75×1.5 cm2) – were used to quantify typical variations (uncertainties) due to scanner fluctuations, misalignment, film inhomogeneity, long-term effect of film cutting, small rotations, film curling, edge effects and the influence of opaque templates. Fitting functions and temporal validity of sensitometric curves were also assessed.ResultsFilm curling, intra-film variability and scanner fluctuations are important effects that need to be minimized or considered in the uncertainty budget. Small rotations, misalignments and film cutting have little or no influence on the readings. Most fitting functions perform well, but the quantity used for dose quantification determines over- or under-valuation of dose in the long term. Edge effects and the influence of opaque templates need to be well understood, to allow optimization of methodology to the intended purpose.ConclusionThe proposed method allows practical and simultaneous digitization of up to ten small irradiated film samples, with an experimental uncertainty of 1%.  相似文献   

12.

Background

Tribolium castaneum (Herbst) is a major pest of stored grain-based products, and cause severe damage to cereal grains throughout the world. The present investigation was aimed to determine the pesticidal and pest repellent activities of 2α,3β,21β,23,28-penta hydroxyl 12-oleanene against T. castaneum. The compound 2α,3β,21β,23,28-penta hydroxyl 12-oleanene is a triterpenoid which was isolated from the roots of Laportea crenulata Gaud. Surface film technique was used for pesticidal screening, whereas, pest repellency property of the triterpenoid was determined by filter paper disc method.

Results

At 24 hours of exposure duration, significant mortality records (80% and 86%) were observed at doses 0.88 and 1.77 mg/cm2. No significant change in mortality records was observed when duration of exposure was increased up to 48 hours. The triterpenoid showed significant repellency activity at doses 0.47 and 0.94 mg/cm2.

Conclusion

These data suggest that the triterpenoid 2α,3β,21β,23,28-penta hydroxyl 12-oleanene possess both pesticidal and pest repellency activities against T. castaneum and can be used in controlling the pest of grain-based products.

Electronic supplementary material

The online version of this article (doi:10.1186/0717-6287-47-68) contains supplementary material, which is available to authorized users.  相似文献   

13.
BackgroundThree dimensional (3D) echocardiography-derived measurements of myocardial deformation and twist have recently advanced as novel clinical tools. However, with the exception of left ventricular ejection fraction and mass quantifications in hypertension and heart failure populations, the prognostic value of such imaging techniques remains largely unexplored.MethodsWe studied 200 subjects (mean age: 60.2±16 years, 54% female, female n = 107) with known hypertension (n = 51), diastolic heart failure (n = 61), or systolic heart failure (n = 30), recruited from heart failure outpatient clinics. Fifty-eight healthy volunteers were used as a control group. All participants underwent 3D-based myocardial deformation and twist analysis (Artida, Toshiba Medical Systems, Tokyo, Japan). We further investigated associations between these measures and brain natriuretic peptide levels and clinical outcomes.ResultsThe global 3D strain measurements of the healthy, hypertension, diastolic heart failure, and systolic heart failure groups were 28.03%, 24.43%, 19.70%, and 11.95%, respectively (all p<0.001). Global twist measurements were estimated to be 9.49°, 9.77°, 8.32°, and 4.56°, respectively. We observed significant differences regarding 3D-derived longitudinal, radial, and global 3D strains between the different disease categories (p<0.05), even when age, gender, BMI and heart rate were matched. In addition, 3D-derived longitudinal, circumferential, and 3D strains were all highly correlated with brain natriuretic peptide levels (p<0.001). At a mean 567.7 days follow-up (25th–75th IQR: 197–909 days), poorer 3D-derived longitudinal, radial, and global 3D strain measurements remained independently associated with a higher risk of cardiovascular related death or hospitalization due to heart failure, after adjusting for age, gender, and left ventricular ejection fraction (all p<0.05).Conclusions3D-based strain analysis may be a feasible and useful diagnostic tool for discriminating the extent of myocardial dysfunction. Furthermore, it is able to provide a prognostic value beyond traditional echocardiographic parameters in terms of ejection fraction.  相似文献   

14.
Physicochemical and Light Scattering Studies on Ribosome Particles   总被引:2,自引:0,他引:2       下载免费PDF全文
The light scattering technique has been used to measure the molecular weight of Escherichia coli ribosomes. The 30S, 50S, and 70S components have been isolated and purified. The refractive index increment dn/dc was found to have the same value, (0.20 ±0.01) cm3/g, for the three species. The molecular weights are (1.0 ±0.1)·106, (1.7 ±0.1)·106, and (2.9 ±0.3)·106 daltons respectively. Some information about the dimensions in solution (radius of gyration) and the interaction constant (second virial coefficient) have been obtained, and their significance is discussed.  相似文献   

15.

Background

Task group number 40 (TG-40) of the American Association of Physicists in Medicine (AAPM) has recommended calibration of any brachytherapy source before its clinical use. GZP6 afterloading brachytherapy unit is a 60Co high dose rate (HDR) system recently being used in some of the Iranian radiotherapy centers.

Aim

In this study air kerma strength (AKS) of 60Co source number three of this unit was estimated by Monte Carlo simulation and in air measurements.

Materials and methods

Simulation was performed by employing the MCNP-4C Monte Carlo code. Self-absorption of the source core and its capsule were taken into account when calculating air kerma strength. In-air measurements were performed according to the multiple distance method; where a specially designed jig and a 0.6 cm3 Farmer type ionization chamber were used for the measurements. Monte Carlo simulation, in air measurement and GZP6 treatment planning results were compared for primary air kerma strength (as for November 8th 2005).

Results

Monte Carlo calculated and in air measured air kerma strength were respectively equal to 17240.01 μGym2 h−1 and 16991.83 μGym2 h−1. The value provided by the GZP6 treatment planning system (TPS) was “15355 μGym2 h−1”.

Conclusion

The calculated and measured AKS values are in good agreement. Calculated-TPS and measured-TPS AKS values are also in agreement within the uncertainties related to our calculation, measurements and those certified by the GZP6 manufacturer. Considering the uncertainties, the TPS value for AKS is validated by our calculations and measurements, however, it is incorporated with a large uncertainty.  相似文献   

16.
Molecular models of six anthracycline antibiotics and their complexes with 32 distinct DNA octamer sequences were created and analyzed using HINT (Hydropathic INTeractions) to describe binding. The averaged binding scores were then used to calculate the free energies of binding for comparison with experimentally determined values. In parsing our results based on specific functional groups of doxorubicin, our calculations predict a free energy contribution of –3.6 ± 1.1 kcal mol–1 (experimental –2.5 ± 0.5 kcal mol–1) from the groove binding daunosamine sugar. The net energetic contribution of removing the hydroxyl at position C9 is –0.7 ± 0.7 kcal mol–1 (–1.1 ± 0.5 kcal mol–1). The energetic contribution of the 3′ amino group in the daunosamine sugar (when replaced with a hydroxyl group) is –3.7 ± 1.1 kcal mol–1 (–0.7 ± 0.5 kcal mol–1). We propose that this large discrepancy may be due to uncertainty in the exact protonation state of the amine. The energetic contribution of the hydroxyl group at C14 is +0.4 ± 0.6 kcal mol–1 (–0.9 ± 0.5 kcal mol–1), largely due to unfavorable hydrophobic interactions between the hydroxyl oxygen and the methylene groups of the phosphate backbone of the DNA. Also, there appears to be considerable conformational uncertainty in this region. This computational procedure calibrates our methodology for future analyses where experimental data are unavailable.  相似文献   

17.
1. Soluble calf-skin collagen has been denatured thermally between 37° and 60° and the component proteins have been separated on carboxymethylcellulose. 2. Four main fractions have been separated; α and β (in the nomenclature in common usage) and two other fractions. (The α and β components are complex owing to the presence of α1, α2, β1 and β2 parts). 3. Fractions 3 and 4 undergo rapid denaturation between 39° and 40° whereafter fraction 4 remains virtually unchanged even at 60°. 4. That portion of fraction 4 which remains at 60° is thought to be identical with the fraction designated γ by other workers, this fraction being composed of three α-chains in covalent linkage (such bonds are alkali-labile). 5. The equilibrium between α, β and fractions 3 and 4 is apparently reversible since acid-soluble collagen after denaturation at 45° or 60° followed by cooling to 0° for 30min. was found to contain only fraction 4 when chromatographed at 37°.  相似文献   

18.
Long-Range Correlations of Global Sea Surface Temperature   总被引:1,自引:0,他引:1  
Scaling behaviors of the global monthly sea surface temperature (SST) derived from 1870–2009 average monthly data sets of Hadley Centre Sea Ice and SST (HadISST) are investigated employing detrended fluctuation analysis (DFA). The global SST fluctuations are found to be strong positively long-range correlated at all pertinent time-intervals. The value of scaling exponent is larger in the tropics than those in the intermediate latitudes of the northern and southern hemispheres. DFA leads to the scaling exponent α = 0.87 over the globe (60°S~60°N), northern hemisphere (0°N~60°N), and southern hemisphere (0°S~60°S), α = 0.84 over the intermediate latitude of southern hemisphere (30°S~60°S), α = 0.81 over the intermediate latitude of northern hemisphere (30°N~60°N) and α = 0.90 over the tropics 30°S~30°N [fluctuation F(s) ~ sα], which the fluctuations of monthly SST anomaly display long-term correlated behaviors. Furthermore, the larger the standard deviation is, the smaller long-range correlations (LRCs) of SST in the corresponding regions, especially in three distinct upwelling areas. After the standard deviation is taken into account, an index χ = α * σ is introduced to obtain the spatial distributions of χ. There exists an obvious change of global SST in central east and northern Pacific and the northwest Atlantic. This may be as a clue on predictability of climate and ocean variabilities.  相似文献   

19.
To investigate the effects of iontophoresis–ultraviolet A (UVA) cross-linking (CXL) with hypotonic riboflavin solution on the ultrastructural changes in the lamellae, collagen fibrils (CFs), and proteoglycans (PGs) in the central and peripheral stroma of the human corneal buttons. The iontophoresis method was used for the trans-epithelial application of hypotonic riboflavin in ex vivo corneal culture for 5 min. The corneas were irradiated using three methods: Group 1 (G1), a UVA irradiance of 3 mW/cm2 for 30 min; Group 2 (G2), a UVA irradiance of 10 mW/cm2 for 9 min; Group 3 (G3), without UVA irradiation. Three untreated corneas were used as controls (G0). After the CXL procedure, the corneas were processed for electron microscopy. The CF diameter and PGs in each sample were analyzed using the iTEM program. The keratocyte organelles and stromal architecture in the peripheral cornea were better preserved than those in the central cornea. In G1 and G2, the mean CF diameter in the peripheral cornea was significantly higher than that in the central cornea. In G3, the CF diameter in the central cornea was significantly larger than that in the peripheral cornea. Furthermore, differences in PG area size were observed between the central and peripheral corneas in all groups. Riboflavin + UVA application at 3 mW/cm2 for 30 min and 10 mW/cm2 for 9 min was a suitable method of CXL; however, 3 mW/cm2 for 30 min improved the organization and size of the collagen fibrils. CXL treatment applied at the periphery was more effective than that applied at the center.Keyword: Collagen fibrils, Proteoglycans, Cornea, Iontophoresis, Ultraviolet A  相似文献   

20.
IntroductionAlthough obesity is a risk factor for hip osteoarthritis (OA), the role of body composition, if any, is unclear. This study examines whether the body mass index (BMI) and body composition are associated with hip cartilage changes using magnetic resonance imaging (MRI) in community-based adults.Methods141 community-based participants with no clinical hip disease, including OA, had BMI and body composition (fat mass and fat free mass) measured at baseline (1990 to 1994), and BMI measured and 3.0 T MRI performed at follow-up (2009–2010). Femoral head cartilage volume was measured and femoral head cartilage defects were scored in the different hip regions.ResultsFor females, baseline BMI (β = −26 mm3, 95% Confidence interval (CI) -47 to −6 mm3, p = 0.01) and fat mass (β = −11 mm3, 95% CI −21 to −1 mm3, p = 0.03) were negatively associated with femoral head cartilage volume. Also, while increased baseline fat mass was associated with an increased risk of cartilage defects in the central superolateral region of the femoral head (Odds Ratio (OR) = 1.08, 95% CI 1.00–1.15, p = 0.04), increased baseline fat free mass was associated with a reduced risk of cartilage defects in this region (OR = 0.82, 95% CI 0.67–0.99; p = 0.04). For males, baseline fat free mass was associated with increased femoral head cartilage volume (β = 40 mm3, 95% CI 6 to 74 mm3, p = 0.02).ConclusionsIncreased fat mass was associated with adverse hip cartilage changes for females, while increased fat free mass was associated with beneficial cartilage changes for both genders. Further work is required to determine whether modifying body composition alters the development of hip OA.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号