首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Patello-femoral disorders are often caused by changes of patello-femoral and/or tibio-femoral kinematics. However, until now there has been no quantitative in vivo technique, that is able to obtain 3D kinematics and contact areas of all knee compartments simultaneously on a non-invasive basis. The aim of this study was therefore to develop and apply a technique which allows for determination of 3D kinematics and contact areas of the patello-femoral and tibio-femoral joint during different knee flexion angles and under neuromuscular activation patterns. One knee of each of the 10 healthy volunteers was examined in an open MR system under flexing isometric muscle activity at 30 degrees and 90 degrees. Three-dimensional kinematics and contact areas of the patello-femoral and tibio-femoral joints were analyzed by 3D image postprocessing. The reproducibility of the imaging technique yielded a coefficient of variation of 4.6% for patello-femoral, 4.7% for femoro-tibial displacement and 8.6% for contact areas. During knee flexion (30-90 degrees ), patella tilt (opened to medial) decreased (8.8+/-3.4 degrees vs. 4.6+/-3.1 degrees, p<0.05), while lateral patellar shift increased significantly (1.6+/-2.3mm vs. 3.4+/-3.0mm, p<0.05). Furthermore, a significant posterior translation and external rotation of the femur relative to the tibia was observed. Patello-femoral contact areas increased significantly in size (134+/-60mm(2) vs. 205+/-96 mm(2)) during knee flexion. This technique shows a high reproducibility and provides physiologic in vivo data of 3D kinematics and contact areas of the patello-femoral and the tibio-femoral joint during knee flexion. This allows for advanced in vivo diagnostics, and may help to improve therapy of patello-femoral disorders in the future.  相似文献   

2.
The movement of the knee joint consists of a coupled motion between the tibiofemoral and patellofemoral articulations. This study measured the six degrees-of-freedom kinematics of the tibia, femur, and patella using dual-orthogonal fluoroscopy and magnetic resonance imaging. Ten normal knees from ten living subjects were investigated during weightbearing flexion from full extension to maximum flexion. The femoral and the patellar motions were measured relative to the tibia. The femur externally rotated by 12.9 deg and the patella tilted laterally by 16.3 deg during the full range of knee flexion. Knee flexion was strongly correlated with patellar flexion (R(2)=0.91), posterior femoral translation was strongly correlated to the posterior patellar translation (R(2)=0.87), and internal-external rotation of the femur was correlated to patellar tilt (R(2)=0.73) and medial-lateral patellar translation (R(2)=0.63). These data quantitatively indicate a kinematic coupling between the tibia, femur, and patella, and provide base line information on normal knee joint kinematics throughout the full range of weightbearing flexion. The data also suggest that the kinematic coupling of tibia, femur, and patella should be considered when investigating patellar pathologies and when developing surgical techniques to treat knee joint diseases.  相似文献   

3.
Twenty-three knees were sectioned, digitized, and standardized to determine the 'average' three-dimensional bony geometry and ligamentous attachments. Data on normal knee motion were obtained from a cadaveric study. An algorithm was written to simulate three-dimensional patella motion. Verification of the knee model was achieved by determining femoro-tibial and patello-femoral contact locations, as well as ligament length patterns, and comparing the results with published data. The criterion for maximum predicted knee motion with a prosthesis in place was the length of the posterior cruciate ligament. Three total knee replacement surfaces were mathematically generated: flat, laxity and conforming. A greater flexion angle was obtained with a flat tibial surface than for the laxity or conforming. Posterior tibial component displacement increased the range of motion, but only slightly. For all tibial surfaces, increased range of motion was achieved with a 10 degrees posterior tilt of the tibial tray. Anterior femoral component displacement increased motion due to reduction in posterior cruciate tension during flexion. The results are applicable to the design and surgical technique of total knee replacement.  相似文献   

4.
The iliotibial band (ITB) has an important role in knee mechanics and tightness can cause patellofemoral maltracking. This study investigated the effects of increasing ITB tension on knee kinematics. Nine fresh-frozen cadaveric knees had the components of the quadriceps loaded with 175 N. A Polaris optical tracking system was used to acquire joint kinematics during extension from 100° to 0° flexion. This was repeated after the following ITB loads: 30, 60 and 90 N. There was no change with 30 N load for patellar translation. On average, at 60 and 90 N, the patella translated laterally by 0.8 and 1.4 mm in the mid flexion range compared to the ITB unloaded condition. The patella became more laterally tilted with increasing ITB loads by 0.7°, 1.2° and 1.5° for 30, 60 and 90 N, respectively. There were comparable increases in patellar lateral rotation (distal patella moves laterally) towards the end of the flexion cycle. Increased external rotation of the tibia occurred from early flexion onwards and was maximal between 60° and 75° flexion. The increase was 5.2°, 9.5° and 13° in this range for 30, 60 and 90 N, respectively. Increased tibial abduction with ITB loads was not observed. The combination of increased patellar lateral translation and tilt suggests increased lateral cartilage pressure. Additionally, the increased tibial external rotation would increase the Q angle. The clinical consequences and their relationship to lateral retinacular releases may be examined, now that the effects of a tight ITB are known.  相似文献   

5.
In designing a posterior-stabilized total knee arthroplasty (TKA) it is preferable that when the cam engages the tibial spine the contact point of the cam move down the tibial spine. This provides greater stability in flexion by creating a greater jump distance and reduces the stress on the tibial spine. In order to eliminate edge loading of the femoral component on the posterior tibial articular surface, the posterior femoral condyles need to be extended. This provides an ideal femoral contact with the tibial articular surface during high flexion angles. To reduce extensor mechanism impingement in deep flexion, the anterior margin of the tibial articular component should be recessed. This provides clearance for the patella and patella tendon. An in vivo kinematic analysis that determined three dimensional motions of the femorotibial joint was performed during a deep knee bend using fluoroscopy for 20 subjects having a TKA designed for deep flexion. The average weight-bearing range-of-motion was 125 degrees . On average, TKA subjects experienced 4.9 degrees of normal axial rotation and all subjects experienced at least -4.4 mm of posterior femoral rollback. It is assumed that femorotibial kinematics can play a major role in patellofemoral kinematics. In this study, subjects implanted with a high-flexion TKA design experienced kinematic patterns that were similar to the normal knee. It can be hypothesized that forces acting on the patella were not substantially increased for TKA subjects compared with the normal subjects.  相似文献   

6.
Improper patellar tracking is often considered to be the cause of patellar-femoral pain. Unfortunately, our knowledge of patellar-femoral-tibial (knee) joint kinematics is severely limited due to a lack of three-dimensional, noninvasive, in vivo measurement techniques. This study presents the first large-scale, dynamic, three-dimensional, noninvasive, in vivo study of nonimpaired knee joint kinematics during volitional leg extensions. Cine-phase contrast magnetic resonance imaging was used to measure the velocity profiles of the patella, femur, and tibia in 18 unimpaired knees during leg extensions, resisted by a 34 N weight. Bone displacements were calculated through integration and then converted into three-dimensional orientation angles. We found that the patella displaced laterally, superiorly, and anteriorly as the knee extended. Further, patellar flexion lagged knee flexion, patellar tilt was variable, and patellar rotation was fairly constant throughout extension.  相似文献   

7.
Total knee arthroplasty (TKA) is a very successful procedure, but pain or difficulties during activities still persist in patients. Patient outcomes in TKA surgery can be affected by implant design, alignment or patient-related anatomical factors. This paper presents a numerical sensitivity analysis of several TKA types: a fixed bearing, posterior stabilized prosthesis, a high flexion fixed bearing guided motion prosthesis, a mobile bearing prosthesis and a hinge prosthesis. Each prosthesis was virtually implanted on the same cadaver leg model and it underwent a loaded squat, in 10s, between 0° and 120°, similar to several previous experimental tests performed on knee kinematics simulators. The aim of this examination was to investigate the sensitivity of the patello-femoral (PF) and tibio-femoral (TF) contact forces to patient-related anatomical factors, and component position in the different implant types. The following parameters were used for the sensitivity study: the proximo-distal patellar position, the patellar component tilting, the tibial component position and orientation, the locations of the medial and lateral collateral ligaments with respect to femur and tibia and the patellar tendon length. The sensitivity analysis showed that PF contact forces are mostly affected by patella height (increases up to 67% for one TKA type in patella-alta configuration), by an anterior tibial component translation (increases up to 30%), and by patellar component tilting (increases up to 29%); TF contact forces are mostly affected by the anterior displacement of the insertion points of the medial collateral ligament with respect to the reference position (increases up to 48%).  相似文献   

8.
Previous in vivo studies have observed that current designs of posterior stabilised (PS) total knee replacements (TKRs) may be ineffective in restoring normal kinematics in Late flexion. Computer-based models can prove a useful tool in improving PS knee replacement designs. This study investigates the accuracy of a two-dimensional (2D) sagittal plane model capable of predicting the functional sagittal plane kinematics of PS TKR implanted knees against direct in vivo measurement. Implant constraints are often used as determinants of anterior–posterior tibio-femoral positioning. This allowed the use of a patello-femoral modelling approach to determine the effect of implant constraints. The model was executed using motion simulation software which uses the constraint force algorithm to achieve a solution. A group of 10 patients implanted with Scorpio PS implants were recruited and underwent fluoroscopic imaging of their knees. The fluoroscopic images were used to determine relative implant orientation using a three-dimensional reconstruction method. The determined relative tibio-femoral orientations were then input to the model. The model calculated the patella tendon angles (PTAs) which were then compared with those measured from the in vivo fluoroscopic images. There were no significant differences between the measured and calculated PTAs. The average root mean square error between measured and modelled ranged from 1.17° to 2.10° over the flexion range. A sagittal plane patello-femoral model could conceivably be used to predict the functional 2D kinematics of an implanted knee joint. This may prove particularly useful in optimising PS designs.  相似文献   

9.
The aim of this study was to evaluate the accuracy with which mobile biplane X-ray imaging can be used to measure patellofemoral kinematics of the intact knee during overground gait. A unique mobile X-ray imaging system tracked and recorded biplane fluoroscopic images of two human cadaver knees during simulated overground walking at a speed of 0.7 m/s. Six-degree-of-freedom patellofemoral kinematics were calculated using a bone volumetric model-based method and the results then compared against those derived from a gold-standard bead-based method. RMS errors for patellar anterior translation, superior translation and lateral shift were 0.19 mm, 0.34 mm and 0.37 mm, respectively. RMS errors for patellar flexion, lateral tilt and lateral rotation were 1.08°, 1.15° and 1.46°, respectively. The maximum RMS error for patellofemoral translations was approximately one-half that reported previously for tibiofemoral translations using the same mobile X-ray imaging system while the maximum RMS error for patellofemoral rotations was nearly two times larger than corresponding errors reported for tibiofemoral rotations. The lower accuracy in measuring patellofemoral rotational motion is likely explained by the symmetric nature of the patellar geometry and the smaller size of the patella compared to the tibia.  相似文献   

10.
In vivo patellofemoral forces in high flexion total knee arthroplasty   总被引:1,自引:0,他引:1  
This study compares the in vivo patellofemoral contact forces generated in high flexion fixed bearing posterior cruciate retaining Nexgen CR-Flex (PCR) and high flexion posterior stabilized Nexgen LPS-Flex (LPS) TKAs with that of normal knees from full knee extension to maximum weight bearing flexion. Ten patients with the PCR total knee arthroplasty (TKA), ten with the LPS TKA and seven patients having normal knees were fluoroscoped while performing a deep knee bend activity. In vivo femorotibial kinematics, obtained from 3D-to-2D registration technique, and patellar kinematics obtained by direct measurements from the fluoroscopic images were entered into a 3D inverse dynamics mathematical model to determine the in vivo contact forces at the knee. The variation in the patellofemoral and quadriceps forces with flexion were found to be similar across the three groups-increasing from full extension to 90 degrees of flexion, reaching a maximum between 90 degrees and 120 degrees of flexion and then decreasing until maximum flexion. At maximum knee flexion, these forces were found to be significantly lower in the normal knees than in the TKAs. The patellar ligament to quadriceps force ratio decreased with the increase in knee flexion while the patellofemoral to quadriceps force ratio increased. A strong correlation was found to exist between the patellofemoral forces, the femorotibial contact forces and the forces in the extensor mechanism. The PCR TKA in this study exhibited greater resemblance to the normal patients with respect to the patellofemoral forces than the LPS TKA though significant differences in the two implant types were not observed.  相似文献   

11.
An electrogomiometric method was used together with a new standardized radiographic technique to accurately determine the rotation of the patella during knee flexion of both normal subjects and patients referred for retropatellar pain. A preliminary study using these techniques shows that retropatellar pain is very much a multi-factoral clinical problem and that combinations of patello-femoral articulation abnormalities, patellar shape and mechanical influences are present in all forms of the painful patella.  相似文献   

12.
BACKGROUND: The management of soft tissue balance during surgery is essential for the success of total knee arthroplasty (TKA) but remains difficult, leaving it much to the surgeon's feel. Previous assessments for soft tissue balance have been performed under unphysiological joint conditions, with patellar eversion and without the prosthesis only at extension and 90 deg of flexion. We therefore developed a new tensor for TKA procedures, enabling soft tissue balance assessment throughout the range of motion while reproducing postoperative joint alignment with the patellofemoral (PF) joint reduced and the tibiofemoral joint aligned. Our purpose in the present study was to clarify joint gap kinematics using the tensor with the CT-free computer assisted navigation system. METHOD OF APPROACH: Joint gap kinematics, defined as joint gap change during knee motion, was evaluated during 30 consecutive, primary posterior-stabilized (PS) TKA with the navigation system in 30 osteoarthritic patients. Measurements were performed using a newly developed tensor, which enabled the measurement of the joint gap throughout the range of motion, including the joint conditions relevant after TKA with PF joint reduced and trial femoral component in place. Joint gap was assessed by the tensor at full extension, 5 deg, 10 deg, 15 deg, 30 deg, 45 deg, 60 deg, 90 deg, and 135 deg of flexion with the patella both everted and reduced. The navigation system was used to obtain the accuracy of implantations and to measure an accurate flexion angle of the knee during the intraoperative joint gap measurement. RESULTS: Results showed that the joint gap varied depending on the knee flexion angle. Joint gap showed an accelerated decrease during full knee extension. With the PF joint everted, the joint gap increased throughout knee flexion. In contrast, the joint gap with the PF joint reduced increased with knee flexion but decreased after 60 deg of flexion. CONCLUSIONS: We clarified the characteristics of joint gap kinematics in PS TKA under physiological and reproducible joint conditions. Our findings can provide useful information for prosthetic design and selection and allow evaluation of surgical technique throughout the range of knee motion that may lead to consistent clinical outcomes after TKA.  相似文献   

13.
The objective of the current study was to use fluoroscopy to accurately determine the three-dimensional (3D), in vivo, weight-bearing kinematics of 10 normal and five anterior cruciate ligament deficient (ACLD) knees. Patient-specific bone models were derived from computed tomography (CT) data. 3D computer bone models of each subject's femur, tibia, and fibula were recreated from the CT 3D bone density data. Using a model-based 3D-to-2D imaging technique registered CT images were precisely fit onto fluoroscopic images, the full six degrees of freedom motion of the bones was measured from the images. The computer-generated 3D models of each subject's femur and tibia were precisely registered to the 2D digital fluoroscopic images using an optimization algorithm that automatically adjusts the pose of the model at various flexion/extension angles. Each subject performed a weight-bearing deep knee bend while under dynamic fluoroscopic surveillance. All 10 normal knees experienced posterior femoral translation of the lateral condyle and minimal change in position of the medial condyle with progressive knee flexion. The average amount of posterior femoral translation of the lateral condyle was 21.07 mm, whereas the average medial condyle translation was 1.94 mm, in the posterior direction. In contrast, all five ACLD knees experienced considerable change in the position of the medial condyle. The average amount of posterior femoral translation of the lateral condyle was 17.00 mm, while the medial condyle translation was 4.65 mm, in the posterior direction. In addition, the helical axis of motion was determined between maximum flexion and extension. A considerable difference was found between the center of rotation locations of the normal and ACLD subjects, with ACLD subjects exhibiting substantially higher variance in kinematic patterns.  相似文献   

14.
15.
This study was performed to evaluate a dynamic multibody model developed to characterize the influence of tibial tuberosity realignment procedures on patellofemoral motion and loading. Computational models were created to represent four knees previously tested at 40°, 60°, and 80° of flexion with the tibial tuberosity in a lateral, medial and anteromedial positions. The experimentally loaded muscles, major ligaments of the knee, and patellar tendon were represented. A repeated measures ANOVA with post-hoc testing was performed at each flexion angle to compare data between the three positions of the tibial tuberosity. Significant experimental trends for decreased patella flexion due to tuberosity anteriorization and a decrease in the lateral contact force due to tuberosity medialization were reproduced computationally. The dynamic multibody modeling technique will allow simulation of function for symptomatic knees to identify optimal surgical treatment methods based on parameters related to knee pathology and pre-operative kinematics.  相似文献   

16.
The purpose of this study was to determine the consistency and symmetry of in vivo measures of patellar spin, tilt, and medial/lateral translation in healthy knees. Patellofemoral joint kinematics were measured bilaterally through a range of loaded knee flexion in 10 active males (aged 19.0 (0.57) years) at baseline, 6, and 12 months using a validated magnetic resonance imaging method. Effects due to time and limb were determined using ANOVA. Variation over 12 months and from side-to-side was summarized as the average of the mean absolute deviations of the measures at 1 degrees increments of knee flexion for corresponding loading cycles for each knee. The measures did not differ over time (p>0.52) or side-to-side (p>0.17). The mean intrasubject variability over the three time points was < or = 1.17 (0.3) degrees for spin and tilt and < or = 0.83 (0.61) mm for lateral translation. The mean intrasubject variability between limbs was 2.14 (1.29) degrees for spin, 0.46 (1.96) degrees for tilt and 1.29 (1.28)mm for lateral translation. The consistency of measures of normal patellar motion over a 1 year period supports application of this methodology to evaluate changes in patellar motion in longitudinal studies involving patient populations.  相似文献   

17.
Knowledge of the coupled motions, which develop under compressive loading of the knee, is useful to determine which degrees of freedom should be included in the study of tibiofemoral contact and also to understand the role of the anterior cruciate ligament (ACL) in coupled motions. The objectives of this study were to measure the coupled motions of the intact knee and ACL-deficient knee under compression and to compare the coupled motions of the ACL-deficient knee with those of the intact knee. Ten intact cadaveric knees were tested by applying a 1600 N compressive load and measuring coupled internal-external and varus-valgus rotations and anterior-posterior and medial-lateral translations at 0 deg, 15 deg, and 30 deg of flexion. Compressive loads were applied along the functional axis of axial rotation, which coincides approximately with the mechanical axis of the tibia. The ACL was excised and the knees were tested again. In the intact knee, the peak coupled motions were 3.8 deg internal rotation at 0 deg flexion changing to -4.9 deg external rotation at 30 deg of flexion, 1.4 deg of varus rotation at 0 deg flexion changing to -1.9 deg valgus rotation at 30 deg of flexion, 1.4 mm of medial translation at 0 deg flexion increasing to 2.3 mm at 30 deg of flexion, and 5.3 mm of anterior translation at 0 deg flexion increasing to 10.2 mm at 30 deg of flexion. All changes in the peak coupled motions from 0 deg to 30 deg flexion were statistically significant (p<0.05). In ACL-deficient knees, there was a strong trend (marginally not significant, p=0.07) toward greater anterior translation (12.7 mm) than that in intact knees (8.0 mm), whereas coupled motions in the other degrees of freedom were comparable. Because the coupled motions in all four degrees of freedom in the intact knee and ACL-deficient knee are sufficiently large to substantially affect the tibiofemoral contact area, all degrees of freedom should be included when either developing mathematical models or designing mechanical testing equipment for study of tibiofemoral contact. The increase in coupled anterior translation in ACL-deficient knees indicates the important role played by the ACL in constraining anterior translation during compressive loading.  相似文献   

18.
An unconstrained loading system was developed to measure the passive envelope of joint motion in an animal model commonly used to study ligament healing and joint arthritis. The design of the five-degree-of-freedom system allowed for unconstrained knee joint loading throughout flexion with repeated removal and reapplication of the device to a specimen. Seven New Zealand White rabbit knees were subjected to varus, valgus, internal and external loads, and the resulting envelopes of motion were recorded using an electromagnetic tracking device. Intra-specimen reproducibility was excellent when measured in one specimen, with maximal rotational differences of 0.6 and 0.3 deg between the fourth and fifth testing cycles for the varus (VR) and valgus (VL) envelopes, respectively. Similarly, the maximal internal (INT) and external (EXT) envelope differences were 0.5 and 0.4 deg, respectively, between the fourth and fifth cycles. Good inter-animal envelope reproducibility was also observed with consistent motion pathways for each loading condition. A maximal VR-VL laxity of 17.9 +/- 2.3 deg was recorded at 95 deg flexion for the seven knees tested. The maximal INT-EXT laxity of 75.2 +/- 4.8 deg occurred at 50 deg flexion. Studies on measurement reproducibility of re-applying individual testing components demonstrated a maximal error of 1.2 +/- 0.7 deg. Serial removal and re-application (test-retest) of the complete measuring system to one cadaveric knee demonstrated maximal envelope differences of less than 0.7 deg for VR-VL rotation and 2.1 deg for INT-EXT rotation. Our results demonstrate that the measuring system is reproducible and capable of accurate evaluation of knee joint motion. Baseline in vitro data were generated on normal joint kinematics for future in-vivo studies with this system, evaluating ligament healing and disease progression in arthritis models.  相似文献   

19.
Studies of three-dimensional patellar kinematics done with little or no applied load may not accurately reflect kinematics at physiological load levels, and may provide different results to those acquired with greater applied loads or in physiologic weightbearing. We report the effect of load magnitude on three-dimensional patellar kinematics (flexion, spin and tilt; proximal, lateral and anterior translation) using a validated, sequential static, MRI-based method. Ten healthy subjects loaded their study knee to 0% (no load), 15% and 30% bodyweight (BW) using a custom designed loading rig. Differences between loading levels were determined as a function of knee flexion for each kinematic parameter using linear hierarchical random-effects models. Quadratic and random slope terms were included in the models when significant. We found that the patellae flexed less with knee flexion at 30% BW load compared to 0% BW load (p<0.001) and 15% BW (p=0.004) load. The patellae showed a slight medial tilt with knee flexion at 30% BW load which was significantly less than the medial tilt seen at 0% BW load (p=0.017) and 15% BW load (p=0.043) with knee flexion. Small but statistically significant differences were also observed for proximal and anterior translation; the patellae were in a more proximal and posterior position at 30% BW load than at 0% BW load (p=0.010 and p=0.005, respectively) and 15% BW load (p<0.001 and p=0.029, respectively). Since differences in three-dimensional patellar kinematics were observed between loading levels, magnitudes of prescribed loads must be considered when designing studies and comparing results between studies.  相似文献   

20.
Total knee arthroplasty (TKA) is a successful procedure for osteoarthritis. However, some patients (19%) do have pain after surgery. A finite element model was developed based on boundary conditions of a knee rig. A 3D-model of an anatomical full leg was generated from magnetic resonance image data and a total knee prosthesis was implanted without patella resurfacing. In the finite element model, a restarting procedure was programmed in order to hold the ground reaction force constant with an adapted quadriceps muscle force during a squat from 20° to 105° of flexion. Knee rig experimental data were used to validate the numerical model in the patellofemoral and femorotibial joint. Furthermore, sensitivity analyses of Young’s modulus of the patella cartilage, posterior cruciate ligament (PCL) stiffness, and patella tendon origin were performed. Pearson’s correlations for retropatellar contact area, pressure, patella flexion, and femorotibial ap-movement were near to 1. Lowest root mean square error for retropatellar pressure, patella flexion, and femorotibial ap-movement were found for the baseline model setup with Young’s modulus of 5 MPa for patella cartilage, a downscaled PCL stiffness of 25% compared to the literature given value and an anatomical origin of the patella tendon. The results of the conducted finite element model are comparable with the experimental results. Therefore, the finite element model developed in this study can be used for further clinical investigations and will help to better understand the clinical aspects after TKA with an unresurfaced patella.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号