首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
BackgroundSerological diagnosis of Zika virus (ZIKV) infection is challenging because of the antibody cross-reactivity among flaviviruses. At the same time, the role of Nucleic Acid Testing (NAT) is limited by the low proportion of symptomatic infections and the low average viral load. Here, we compared the diagnostic performance of commercially available IgM, IgAM, and IgG ELISAs in sequential samples during the ZIKV and chikungunya (CHIKV) epidemics and co-circulation of dengue virus (DENV) in Brazil and Venezuela.Methodology/Principal findingsAcute (day of illness 1–5) and follow-up (day of illness ≥ 6) blood samples were collected from nine hundred and seven symptomatic patients enrolled in a prospective multicenter study between June 2012 and August 2016. Acute samples were tested by RT-PCR for ZIKV, DENV, and CHIKV. Acute and follow-up samples were tested for IgM, IgAM, and IgG antibodies to ZIKV using commercially available ELISAs. Among follow-up samples with a RT-PCR confirmed ZIKV infection, anti-ZIKV IgAM sensitivity was 93.5% (43/46), while IgM and IgG exhibited sensitivities of 30.3% (10/33) and 72% (18/25), respectively. An additional 24% (26/109) of ZIKV infections were detected via IgAM seroconversion in ZIKV/DENV/CHIKV RT-PCR negative patients. The specificity of anti-ZIKV IgM was estimated at 93% and that of IgAM at 85%.Conclusions/SignificanceOur findings exemplify the challenges of the assessment of test performance for ZIKV serological tests in the real-world setting, during co-circulation of DENV, ZIKV, and CHIKV. However, we can also demonstrate that the IgAM immunoassay exhibits superior sensitivity to detect ZIKV RT-PCR confirmed infections compared to IgG and IgM immunoassays. The IgAM assay also proves to be promising for detection of anti-ZIKV seroconversions in sequential samples, both in ZIKV PCR-positive as well as PCR-negative patients, making this a candidate assay for serological monitoring of pregnant women in future ZIKV outbreaks.  相似文献   

2.
Crimean-Congo Hemorrhagic Fever Virus (CCHFV) is a geographically widespread tick-borne arbovirus that has been recognized by the WHO as an emerging pathogen needing urgent attention to ensure preparedness for potential outbreaks. Therefore, availability of accurate diagnostic tools for identification of acute cases is necessary.A panel comprising 121 sequential serum samples collected during acute, convalescent and subsided phase of PCR-proven CCHFV infection from 16 Kosovar patients was used to assess sensitivity. Serum samples from 60 healthy Kosovar blood donors were used to assess specificity. All samples were tested with two IgM/IgG immunofluorescence assays (IFA) from BNITM, the CCHFV Mosaic 2 IgG and IgM indirect immunofluorescence tests (IIFT) from EUROIMMUN, two BlackBox ELISAs for the detection of CCHFV-specific IgM and IgG antibodies (BNITM), two Anti-CCHFV ELISAs IgM and IgG from EUROIMMUN using recombinant structural proteins of CCHFV antigens, and two ELISAs from Vector-Best (IgM: μ-capture ELISA, IgG: indirect ELISA using immobilized CCHFV antigen). Diagnostic performances were compared between methods using sensitivity, specificity, concordance and degree of agreement with particular focus on the phase of the infection.In early and convalescent phases of infection, the sensitivities for detecting specific IgG antibodies differed for the ELISA test. The BlackBox IgG ELISA yielded the highest, followed by the EUROIMMUN IgG ELISA and finally the VectorBest IgG ELISA with the lowest sensitivities. In the subsided phase, the VectorBest IgM ELISA detected a high rate of samples that were positive for anti-CCHFV IgM antibodies. Both test systems based on immunofluorescence showed an identical sensitivity for detection of anti-CCHFV IgM antibodies in acute and convalescent phases of infection.Available serological test systems detect anti-CCHFV IgM and IgG antibodies accurately, but their diagnostic performances vary with respect to the phase of the infection.  相似文献   

3.
Dengue and chikungunya are acute viral infections with overlapping clinical symptoms. Both diseases are transmitted by common mosquito vectors resulting in their co‐circulation in a region. Molecular and serological tests specific for both dengue and chikungunya infections were performed on 87 acute phase blood samples collected from patients with suspected dengue/chikungunya infections in Delhi from September to December, 2011. RT‐PCR and IgM ELISA were performed to detect dengue virus (DENV) and chikungunya virus (CHIKV). NS1 and IgG ELISA were also performed to detect DENV specific antigen and secondary DENV infection. DENV infection was detected in 49%, CHIKV infection in 29% and co‐infection with DENV and CHIKV in 10% of the samples by RT‐PCR. DENV serotypes 1, 2 and 3 were detected in this study. Nine DENV‐1 strains, six DENV‐2 strains and 20 CHIKV strains were characterized by DNA sequencing and phylogenetic analysis of their respective envelope protein genes. DENV‐1 strains grouped in the American African genotype, DENV‐2 strains in the Cosmopolitan genotype and CHIKV strains in the East Central South African genotype by phylogenetic analysis. This is one of the few studies reporting the phylogeny of two dengue virus serotypes (DENV‐1 and DENV‐2) and CHIKV. Surveillance and monitoring of DENV and CHIKV strains are important for design of strategies to control impending epidemics.  相似文献   

4.
IntroductionChikungunya virus (CHIKV) is a mosquito-borne virus known to cause acute febrile illness associated with debilitating polyarthritis. In 2019, several institutions in Myanmar reported a CHIKV outbreak. There are no official reports of CHIKV cases between 2011 and 2018. Therefore, this study sought to determine the seroprevalence of CHIKV infection before the 2019 outbreak.MethodsA total of 1,544 serum samples were collected from healthy volunteers and patients with febrile illnesses in Yangon, Mandalay, and the Myeik district in 2013, 2015, and 2018. Participants ranged from one month to 65 years of age. Antibody screening was performed with in-house anti-CHIKV IgG and IgM ELISA. A neutralization assay was used as a confirmatory test.ResultsThe seroprevalence of anti-CHIKV IgM and anti-CHIKV IgG was 8.9% and 28.6%, respectively, with an overall seropositivity rate of 34.5%. A focus reduction neutralization assay confirmed 32.5% seroprevalence of CHIKV in the study population. Age, health status, and region were significantly associated with neutralizing antibodies (NAbs) and CHIKV seropositivity (p < 0.05), while gender was not (p = 0.9). Seroprevalence in 2013, 2015, and 2018 was 32.1%, 28.8%, and 37.3%, respectively. Of the clinical symptoms observed in participants with fevers, arthralgia was mainly noted in CHIKV-seropositive patients.ConclusionThe findings in this study reveal the circulation of CHIKV in Myanmar’s Mandalay, Yangon, and Myeik regions before the 2019 CHIKV outbreak. As no treatment or vaccine for CHIKV exists, the virus must be monitored through systematic surveillance in Myanmar.  相似文献   

5.

Background

Toxoplasmosis is typically diagnosed by serologic testing. External quality assessment (EQA) of clinical laboratories could ensure the accuracy and reliability of serological tests. We assessed the quality of toxoplasma serological assays in Chinese clinical laboratories by an EQA performed between 2004 and 2013 by the National Center for Clinical Laboratories.

Methodology and Findings

EQA panels were prepared and shipped at room temperature to participating laboratories that employed toxoplasma IgG and IgM serological detection. By 2013, 5,384 EQA test reports for toxoplasma-specific IgM and 2,666 reports for toxoplasma-specific IgG were collected. Enzyme-linked immunosorbent (ELISA) and chemical immunofluorescent assays were the most commonly used detection methods. The overall coincidence rates of negative samples were better than those of positive samples. The overall EQA score for toxoplasma-specific IgM detection ranged between 84.3% and 99.6%. The ratio of laboratories that achieved correct IgG detection ranged from 61.1% to 99.3%. However, the inter- and intra-assay variabilities were found to be considerable. The most common problem was failure to detect low titers of antibody.

Conclusion

The EQA scheme showed an improvement in toxoplasma serological testing in China. However, further optimization of assay sensitivity to detect challenging samples remains a future challenge.  相似文献   

6.
7.
Toxoplasma gondii ME49 infections are typically diagnosed by serological tests. However, serological diagnosis of RH strain-induced toxoplasmosis remains unknown. In order to develop seradiagnosis of above 2 kinds of infections, we generated recombinant virus-like particles (VLPs) displaying the T. gondii rhoptry protein 4 (ROP4) and evaluated their potential in T. gondii ME49 or RH strain infection diagnostics. Mice were orally infected with either the tachyzoites of T. gondii (RH) or cysts of T. gondii (ME49) at various dosages, and sera were collected at regular intervals. ELISA-based serological tests were performed to assess IgG, IgM, and IgA antibody responses against ROP4 VLP antigen and tissue lysate antigen (TLA). Compared to TLA, IgG, IgM, and IgA levels to ROP4 VLP antigen were significantly higher in the sera of T. gondii RH-infected mice 1 and 2 week post-infection (PI). T. gondii-specific IgG antibody was detected at 1, 2, 4, and 8 week PI in the T. gondii ME49-infected mice with infection dose-dependent manner. These results indicated that the ROP4 VLP antigen was highly sensitive antigens detecting T. gondii RH and ME49 antibodies at an early stage.  相似文献   

8.

Background

In recent decades, sporadic cases and outbreaks in humans of West Nile virus (WNV) infection have increased. Serological diagnosis of WNV infection can be performed by enzyme-linked immunosorbent assay (ELISA), immunofluorescence assay (IFA) neutralization test (NT) and by hemagglutination-inhibition assay. The aim of this study is to collect updated information regarding the performance accuracy of WNV serological diagnostics.

Methodology/Principal findings

In 2011, the European Network for the Diagnostics of Imported Viral Diseases-Collaborative Laboratory Response Network (ENIVD-CLRN) organized the second external quality assurance (EQA) study for the serological diagnosis of WNV infection. A serum panel of 13 samples (included sera reactive against WNV, plus specificity and negative controls) was sent to 48 laboratories involved in WNV diagnostics. Forty-seven of 48 laboratories from 30 countries participated in the study. Eight laboratories achieved 100% of concurrent and correct results. The main obstacle in other laboratories to achieving similar performances was the cross-reactivity of antibodies amongst heterologous flaviviruses. No differences were observed in performances of in-house and commercial test used by the laboratories. IFA was significantly more specific compared to ELISA in detecting IgG antibodies. The overall analytical sensitivity and specificity of diagnostic tests for IgM detection were 50% and 95%, respectively. In comparison, the overall sensitivity and specificity of diagnostic tests for IgG detection were 86% and 69%, respectively.

Conclusions/Significance

This EQA study demonstrates that there is still need to improve serological tests for WNV diagnosis. The low sensitivity of IgM detection suggests that there is a risk of overlooking WNV acute infections, whereas the low specificity for IgG detection demonstrates a high level of cross-reactivity with heterologous flaviviruses.  相似文献   

9.
BackgroundSchistosomiasis, an acute and chronic parasitic disease caused by human pathogenic Schistosoma species, is a neglected tropical disease affecting more than 220 million people worldwide.For diagnosis of schistosomiasis, stool and urine microscopy for egg detection is still the recommended method, however sensitivity of these methods is limited. Therefore, other methods like molecular detection of DNA in stool, detection of circulating cathodic antigen in urine or circulating anodic antigen in urine and serum, as well as serological tests have gained more attention. This study examines the sensitivity and specificity of a rapid diagnostic test based on immunochromatography (Schistosoma ICT IgG-IgM, LD Bio, Lyon, France) for simultaneous detection of specific IgG and IgM antibodies in serum, against Schistosoma spp. in endemic and non-endemic populations.Methodology/Principal findingsFrozen banked serum samples from patients with confirmed schistosomiasis, patients with other helminth infections, patients with seropositive rheumatoid arthritis and healthy blood donors were used to assess the sensitivity and the specificity of the Schistosoma ICT IgG-IgM rapid diagnostic test.The test showed a sensitivity of 100% in patients with parasitologically confirmed schistosomiasis, irrespective of the species (S. mansoni, S. haematobium, S. japonicum, S. mekongi). In healthy blood donors and patients with rheumatoid factor positive rheumatoid arthritis from Europe, specificity was 100%. However, in serum samples of patients with other tissue invasive helminth infections, the test showed some cross-reactivity, resulting in a specificity of 85%.Conclusion/SignificanceWith its high sensitivity, the Schistosoma ICT IgG-IgM rapid diagnostic test is a suitable screening test for detection of Schistosoma specific antibodies, including S. mekongi. However, in populations with a high prevalence of co-infection with other tissue invasive helminths, positive results should be confirmed with other diagnostic assays due to the test’s imperfect specificity.  相似文献   

10.
Mumps is an infectious disease caused by mumps virus (MuV), which belongs to the family Paramyxoviridae and genus Rubulavirus. Typical symptoms of mumps include fever and swelling of the parotid glands; however, mumps can be asymptomatic. Mumps is diagnosed by molecular and serological methods (i.e., PCR and Enzyme Immunoassay [EIA]); however, both methods have pros and cons. This study was performed to compare the diagnostic utility of a focus reduction neutralization test (FRNT) to that of MuV‐specific commercial IgM and IgG antibody EIA in patients suspected of having mumps. One hundred‐eighty six samples collected during mumps outbreak in 2012–16 were studied. Samples (n = 80) were tested by all the three serological assays and showed 70.4%, 83% and 92.5% positivity by IgM EIA, IgG and FRNT, respectively. In all, 58.8% samples (n = 47) tested positive in all three assays. Concordance between mumps RT‐PCR and IgM EIA was highest during the first 2–5 days and decreased with increasing time post‐onset. Mumps FRNT results agreed with those of RT‐PCR/IgM EIA from the second week onwards, whereas the results of mumps IgG EIA agreed with those of RT‐PCR/IgM EIA from post‐onset days 3–10. These findings suggest the utility of a FRNT for laboratory diagnosis of mumps in countries whose populations are not immunized against this infection.
  相似文献   

11.
The aim of this study was to determine whether separate measurement of immunoglobulin (Ig) M and G antibodies to Legionella (L.) pneumophila serogroups (sg) 1, 3 and 6 as single antigens can facilitate an early diagnosis of Legionnaires' disease. The developed ELISA was evaluated and compared with an in-house indirect Legionella immunofluorescence antibody test (IFAT) measuring Total Ig. A total of 193 sera from 128 patients with confirmed L. pneumophila infections were used to assess the sensitivity of the developed ELISA. The sensitivity was assessed in different time-periods after onset of symptoms. It was found that the sensitivity of the test increased during the first month of infection, IgM being the most sensitive; ranging from 13% in the first week after onset of symptoms, 45% in the second week to 84% in the third week; in the fourth (and beyond) week a drop to 67% was observed. The IFAT detecting L. pneumophila sg 1-6 had a sensitivity of 11%, 27%, 80% and 59%, respectively, during these time-periods. The test with the lowest sensitivity was the IgG ELISA (0%, 21%, 36% and 52%), but by combining the IgG results with the IgM results, the overall sensitivity of the assay was improved (13%, 48%, 88% and 70%).This study confirms that detection of IgG and IgM antibodies by ELISA is an important diagnostic tool especially during the initial phase of the disease, when supported by other tests like the urinary antigen test, PCR or culture.Furthermore, we showed that the ELISA is suitable for the detection of significant changes in antibody levels in paired serum samples. It was found that the sensitivity was higher for the ELISA assays than for the IFAT. Both the in-house IgM ELISA and the IFAT had a low false positive rate, while a 14% false positive rate was found for the IgG ELISA among serum samples from patients with other infections.  相似文献   

12.
Keeping in view the complications and the case fatality associated with dengue virus, several serologic tests have been developed. However, the major drawback of these serologic tests is the need for a venous blood sample obtained by invasive venipuncture. As a noninvasive alternative, saliva provides a body fluid that contains antibodies of diagnostic importance. Hence, the detection of DEN-specific IgM and IgG antibodies in serum and saliva from 80 patients was compared. Salivary IgM antibodies were detected in 100% of the serum IgM-positive samples and in 30% of the serum samples that were negative for IgM antibodies. Salivary IgG antibodies were detected in 93.3% of the serum samples that were positive for anti-dengue IgG antibodies and in none of the serum IgG-negative cases. None of the specimens from the healthy controls showed the presence of IgM or IgG antibodies. The detection of both IgG and IgM antibodies in saliva correlated well with the serum IgG and IgM detection by the ELISA test (r = 0.6322 and r = 0.4227). Detection of salivary IgM antibodies by ELISA showed 100% sensitivity, 70% specificity, 90.9% positive predictive value, and 100% negative predictive value. The detection of IgG in saliva proved to be a promising tool as the sensitivity, specificity, positive predictive value, and negative predictive value were found out to be 93.3%, 100%, 100%, and 83.3%, respectively. Thus, from this study we conclude that the detection of DEN-specific salivary IgG and IgM antibodies are useful markers for dengue infection.  相似文献   

13.
Chikungunya virus (CHIKV) is known to cause sporadic or explosive outbreaks. However, little is known about the endemic transmission of CHIKV. To ascertain the endemic occurrence of CHIKV transmission, we tested blood samples from patients with a non-dengue febrile illness who participated in a prospective cohort study of factory workers in Bandung, Indonesia. From August 2000 to June 2004, and September 2006 to April 2008, 1901 febrile episodes occurred and 231 (12.2%) dengue cases were identified. The remaining febrile cases were evaluated for possible CHIKV infection by measuring anti-CHIKV IgM and IgG antibodies in acute and convalescent samples. Acute samples of serologically positive cases were subsequently tested for the presence of CHIKV RNA by RT-PCR and/or virus isolation. A total of 135 (7.1%) CHIKV infections were identified, providing an incidence rate of 10.1/1,000 person years. CHIKV infections were identified all year round and tended to increase during the rainy season (January to March). Severe illness was not found and severe arthralgia was not a prominently reported symptom. Serial post-illness samples from nine cases were tested to obtain a kinetic picture of IgM and IgG anti-CHIKV antibodies. Anti-CHIKV IgM antibodies were persistently detected in high titers for approximately one year. Three patients demonstrated evidence of possible sequential CHIKV infections. The high incidence rate and continuous chikungunya cases in this adult cohort suggests that CHIKV is endemically transmitted in Bandung. Further characterization of the circulating strains and surveillance in larger areas are needed to better understand CHIKV epidemiology in Indonesia.  相似文献   

14.

Background

The sensitivity and specificity of two in-house MAC-ELISA assays were tested and compared with the performance of commercially-available CTK lateral flow rapid test and EUROIMMUN IFA assays for the detection of anti-Chikungunya virus (CHIKV) IgM. Each MAC-ELISA assay used a whole virus-based antigen derived from genetically distinct CHIKV strains involved in two chikungunya disease outbreaks in Singapore (2008); a January outbreak strain with alanine at amino acid residue 226 of the E1 glycoprotein (CHIKV-A226) and a May-to-September outbreak strain that possessed valine at the same residue (CHIKV-226V). We report differences in IgM detection efficacy of different assays between the two outbreaks. The sensitivities of two PCR protocols were also tested.

Methods and Findings

For sera from January outbreak, the average detection threshold of CTK lateral flow test, MAC-ELISAs and EUROIMMUN IFA assays was 3.75, 4.38 and 4.88 days post fever onset respectively. In contrast, IgM detection using CTK lateral flow test was delayed to more than 7 days after fever onset in the second outbreak sera. However, MAC-ELISA using CHIKV-226V detected IgM in the second outbreak sera 3.96 days after fever onset, which was approximately one day earlier compared to the same assay using CHIKV-A226 (4.86 days). Specificity was 100% for both commercial assays, and 95.6% for the in-house MAC-ELISAs. For sensitivity determination of the PCR protocols, the probe-based real time RT-PCR method was found to be 10 times more sensitive than one based on SYBR Green.

Conclusion

Our findings suggested that the two strains of CHIKV using variants A226 and 226V resulted in variation in sensitivities of the assays evaluated. We postulated that the observed difference in antigen efficacy could be due to the amino acid substitution differences in viral E1 and E2 envelope proteins, especially the E1-A226V substitution. This evaluation demonstrates the importance of appraisal of different diagnostic assays before their application in clinical and operational settings.  相似文献   

15.
BackgroundChikungunya virus (CHIKV) is an important emerging and re-emerging public health problem worldwide. In Indonesia, where the virus is endemic, epidemiological information from outside of the main islands of Java and Bali is limited.Methodology/Principal FindingsFour hundred and seventy nine acutely febrile patients presenting between September 2017–2019 were recruited from three city hospitals situated in Ambon, Maluku; Banjarmasin, Kalimantan; and Batam, Batam Island as part of a multi-site observational study. CHIKV RNA was detected in a single serum sample while a separate sample was IgM positive. IgG seroprevalence was also low across all three sites, ranging from 1.4–3.2%. The single RT-PCR positive sample from this study and 24 archived samples collected during other recent outbreaks throughout Indonesia were subjected to complete coding region sequencing to assess the genetic diversity of Indonesian strains. Phylogenetic analysis revealed all to be of a single clade, which was distinct from CHIKV strains recently reported from neighbouring regions including the Philippines and the Pacific Islands.Conclusions/SignificanceChikungunya virus strains from recent outbreaks across Indonesia all belong to a single clade. However, low-level seroprevalence and molecular detection of CHIKV across the three study sites appears to contrast with the generally high seroprevalences that have been reported for non-outbreak settings in Java and Bali, and may account for the relative lack of CHIKV epidemiological data from other regions of Indonesia.  相似文献   

16.
Dengue has become endemic in Pakistan with annual recurrence. A sudden increase in the dengue cases was reported from Rawalpindi in 2016, while an outbreak occurred for the first time in Peshawar in 2017. Therefore, a multi-center study was carried out to determine the circulating dengue virus (DENV) serotypes and Chikungunya virus (CHIKV) co-infection in Lahore, Rawalpindi, and Peshawar cities in 2016–18. A hospital-based cross-sectional study was carried out in Lahore and Rawalpindi in 2016–18, while a community-based study was carried out in Peshawar in 2017. The study participants were tested for dengue NS1 antigen using an immunochromatographic device while anti-dengue IgM/IgG antibodies were detected by indirect ELISA. All NS1 positive samples were used for DENV serotyping using multiplex real-time PCR assay. Additionally, dengue samples were tested for CHIKV co-infection using IgM/IgG ELISA. A total of 6291 samples were collected among which 8.11% were NS1 positive while 2.5% were PCR positive. DENV-2 was the most common serotype (75.5%) detected, followed by DENV-1 in 16.1%, DENV-3 in 3.9% and DENV-4 in 0.7% while DENV-1 and DENV-4 concurrent infections were detected in 3.9% samples. DENV-1 was the predominant serotype (62.5%) detected from Lahore and Rawalpindi, while DENV-2 was the only serotype detected from Peshawar. Comorbidities resulted in a significant increase (p-value<0.001) in the duration of hospital stay of the patients. Type 2 diabetes mellitus substantially (p-value = 0.004) contributed to the severity of the disease. Among a total of 590 dengue positive samples, 11.8% were also positive for CHIKV co-infection. Co-circulation of multiple DENV serotypes and CHIKV infection in Pakistan is a worrisome situation demanding the urgent attention of the public health experts to strengthen vector surveillance.  相似文献   

17.
18.
ABSTRACT: BACKGROUND: The impact of hepatitis E in developed countries, like Italy, still requires a clear definition. In the present study, we evaluated HEV infection in patients with acute non-A-C hepatitis by an approach comparing data from Real-time PCR and serological assays. METHODS: In a first analysis, sera from 52 patients hospitalized with a diagnosis of acute viral non-A-C hepatitis in Italy were tested by in-house Real-Time PCR assay for identification of Hepatitis E Virus (HEV) RNA and by anti-HEV IgM and IgG assays. In a subsequent analysis, selected samples were evaluated by additional IgM tests to confirm diagnosis. RESULTS: Among the 52 samples, 21 showed positive results for all three markers (IgM, IgG and HEV RNA). One patient showed HEV RNA as single marker. Uncertain results were found in 8 samples while the remaining 22 were negative for all markers. Further analysis of the 8 undefined samples by additional IgM tests confirmed HEV infection in 1 patient. Overall, acute HEV infections were reliably identified in 23 (44.2%) out of 52 patients. CONCLUSIONS: In the present paper, we performed a study evaluating HEV infection in 52 sporadic non-A-C acute hepatitis cases. All samples were collected from 2004 to 2010 in Italy. By a diagnostic strategy based on genomic and serological assays we identified HEV infections in 23 out of 52 patients (44.2%), a percentage higher than previous estimates. Thus, the actual impact of HEV infections in Italy needs to be further evaluated on a national scale by a diagnostic strategy based on multiple and last generation assays.  相似文献   

19.
In this study, we aimed to evaluate the diagnostic value of serological assay for SARS-CoV-2. A newly-developed ELISA assay for IgM and IgG antibodies against N protein of SARS-CoV-2 was used to screen the serums of 238 admitted hospital patients between February 6 and February 14, 2020 with confirmed or suspected SARS-CoV-2. SARS-CoV-2 RNA was detected on pharyngeal swab specimens using real time RT-PCR. 194 (81.5%) of the serums were detected to be antibody (IgM and/or IgG) positive, significantly higher than the positive rate of viral RNA (64.3%). There was no difference in the positive rate of antibodies between the confirmed patients (83.0%, 127/153) and the suspected patients (78.8%, 67/85), whose nucleic acid tests were negative. The antibody positive rates were very low in the first five days after initial onset of symptoms, and then rapidly increased as the disease progressed. After 10 days, the antibody positive rates jumped from below 50% to over 80%. However, the positive rates of viral RNA maintained above 60% in the first 11 days after initial onset of symptoms, and then rapidly decreased. Overall, the suspected patients were most likely infected by SARS-CoV-2. Before the 11th day after initial onset of symptoms, nucleic acid test is key for confirmation of viral infection. The combination of serological assay can greatly improve the diagnostic efficacy. After the 11th day post-disease onset, the diagnosis for viral infection should be majorly dependent on serological assay.  相似文献   

20.
Chlamydia pneumoniae infections are mostly confirmed using an indirect microimmunofluorescence test for which potential cross-reactions between antigens from different chlamydial species are not well documented. Using this assay, 928 sera (507 subjects) submitted for Chlamydia pneumoniae serology were tested for specific IgM and IgG to this bacteria using the TW-183 antigen. IgM and IgG reactivities to Chlamydia trachomatis serotypes C, D, E, and L2 and Chlamydia psittaci strain 6BC antigens were also tested. A sample was interpreted as positive only when evenly fluorescent elementary bodies were observed. Twenty-five subjects (4.9%) showed serological evidence of recent Chlamydia pneumoniae infection (IgM positive and (or) IgG seroconversion); 11 of them also showed serological evidence of recent infection with at least one other chlamydial species. Specificity was 50 and 63% for IgM and IgG detection, respectively. These results suggest that mixed or temporally related infections might occur, or, more likely, that some Chlamydia pneumoniae IgM or IgG reactivities might be due to heterotypic antibodies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号