共查询到20条相似文献,搜索用时 0 毫秒
1.
Quantification of zolmitriptan in plasma by high-performance liquid chromatography-electrospray ionization mass spectrometry 总被引:2,自引:0,他引:2
Zhang Z Xu F Tian Y Li W Mao G 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2004,813(1-2):227-233
A sensitive and specific liquid chromatography electrospray ionization mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and quantification of zolmitriptan in human plasma. After the addition of the internal standard (IS) and 1.0 M sodium hydroxide solution, plasma samples were extracted with methylene chloride:ethyl acetate mixture (20:80, v/v). The organic layer was evaporated under a stream of nitrogen at 40 degrees C. The residue was reconstituted with 100 microl mobile phase. The compounds were separated on a prepacked Lichrospher CN (5 microm, 150 mm x 2.0 mm) column using a mixture of methanol:water (10 mM NH(4)AC, pH 4.0) = 78:22 as mobile phase. Detection was performed on a single quadrupole mass spectrometer by selected ion monitoring (SIM) mode via electrospray ionization (ESI) source. The method was proved to be sensitive and specific by testing six different plasma batches. Linearity was established for the range of concentrations 0.30-16.0 ng/ml with a coefficient of determination (r) of 0.9998 and good back-calculated accuracy and precision. The intra- and inter-day precision (R.S.D.%) were lower than 15% and accuracy ranged from 85 to 115%. The lower limit of quantification was identifiable and reproducible at 0.30 ng/ml. The proposed method enables the unambiguous identification and quantification of zolmitriptan for pharmacokinetic, bioavailability or bioequivalence studies. 相似文献
2.
Hong SS Park JH Kwon SW 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,845(1):69-73
To determine the protein content of formula, gel electrophoresis was performed on the infant formula samples and the entire protein patterns were analyzed by nano-high performance liquid chromatography-electrospray tandem mass spectrometry (nano-HPLC/ESI/MS/MS). From the commercial infant formula profiled in this study, a total of 154 peptides, corresponding to 31 unique proteins were identified by nano-HPLC/ESI/MS/MS. Each of the identified peptides was reconfirmed by a strict integrated approach using tandem mass spectra. This protein profiling method using gel electrophoresis coupled with nano-HPLC/ESI/MS/MS and manual evaluation is a sensitive and accurate method for protein identification as well as a powerful tool for monitoring various types of food products. 相似文献
3.
Chen J Jiang W Cai J Tao W Gao X Jiang X 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2005,824(1-2):249-257
A sensitive and specific liquid chromatography electrospray ionization mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and quantification of lipoic acid (LA) in human plasma. LA and the internal standard, naproxen, were extracted from a 500 microl plasma sample by one-step deproteination using acetonitrile. Chromatographic separation was performed on a Zorbax SB-C(18) Column (100 mmx3.0mm i.d. with 3.5 microm particle size) with the mobile phase consisting of acetonitrile and 0.1% acetic acid (pH 4, adjusted with ammonia solution) (65:35, v/v), and the flow rate was set at 0.3 ml/min. Detection was performed on a single quadrupole mass spectrometer by selected ion monitoring (SIM) mode via electrospray ionization (ESI) source. The method was linear over the concentration range of 5-10,000 ng/ml for LA. The intra- and inter-day precisions were less than 7% and accuracy ranged from -7.87 to 9.74% at the LA concentrations tested. The present method provides a relatively simple and sensitive assay with short turn-around time. The method has been successfully applied to a clinical pharmacokinetic study of LA in 10 healthy subjects. 相似文献
4.
Lansoprazole quantification in human plasma by liquid chromatography-electrospray tandem mass spectrometry 总被引:3,自引:0,他引:3
Oliveira CH Barrientos-Astigarraga RE Abib E Mendes GD da Silva DR de Nucci G 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2003,783(2):453-459
An analytical method based on liquid chromatography with positive ion electrospray ionization (ESI) coupled to tandem mass spectrometry detection was developed for the determination of lansoprazole in human plasma using omeprazole as the internal standard. The analyte and internal standard were extracted from the plasma samples by liquid-liquid extraction using diethyl-ether-dichloromethane (70:30; v/v) and chromatographed on a C(18) analytical column. The mobile phase consisted of acetonitrile-water (90:10; v/v)+10 mM formic acid. The method has a chromatographic total run time of 5 min and was linear within the range 2.5-2000 ng/ml. Detection was carried out on a Micromass triple quadrupole tandem mass spectrometer by Multiple Reaction Monitoring (MRM). The intra- and inter-run precision, calculated from quality control (QC) samples, was less than 3.4%. The accuracy as determined from QC samples was less than 9%. The method herein described was employed in a bioequivalence study of two capsule formulations of lansoprazole. 相似文献
5.
Lisinopril quantification in human plasma by liquid chromatography-electrospray tandem mass spectrometry 总被引:4,自引:0,他引:4
Padua AA Barrientos-Astigarraga RE Rezende VM Mendes GD De Nucci G 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2004,809(2):211-216
An analytical method based on liquid chromatography with positive ion electrospray ionization (ESI) coupled to tandem mass spectrometry detection was developed for the determination of Lisinopril in human plasma using Enalaprilat as internal standard. The analyte and internal standard were extracted from the plasma samples by solid-phase extraction using Waters HLB Oasis SPE cartridges and chromatographed on a C8 analytical column. The mobile phase consisted of acetonitrile/water (60:40, v/v) + 20 mM acetic acid + 4.3 mM of triethylamine. The method had a chromatographic total run-time of 6.5 min and was linear within the range 2.00-200 ng/ml. Detection was carried out on a Micromass triple quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM). The precision (CV%) and accuracy, calculated from limit of quantification (LOQ) samples (n = 8), were 8.9 and 98.9%, respectively. The method herein described was employed in a bioequivalence study of two tablet formulations of Lisinopril 20mg. 相似文献
6.
Determination of glimepiride in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry 总被引:2,自引:0,他引:2
Salem II Idrees J Al Tamimi JI 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2004,799(1):103-109
A sensitive and specific high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS-MS) method has been developed at our center for the determination of glimepiride in human plasma. After the addition of the internal standard, plasma samples were extracted by liquid-liquid extraction technique using diethyl ether. The compounds were separated on a prepacked C18 column using a mixture of acetonitrile, methanol and ammonium acetate buffer as mobile phase. A Finnigan LCQDUO ion trap mass spectrometer connected to an Alliance Waters HPLC was used to develop and validate the method. The analytical method was validated according to the FDA bioanalytical method validation guidance. The results were within the accepted criteria as stated in the aforementioned guidance. The method was proved to be sensitive and specific by testing six different plasma batches. Linearity was established for the range of concentrations 5.0-500.0 ng/ml with a coefficient of determination (r2) of 0.9998. Accuracy for glimepiride ranged from 100.58 to 104.48% at low, mid and high levels. The intra-day precision was better than 12.24%. The lower limit of quantitation (LLOQ) was identifiable and reproducible at 5.0 ng/ml with a precision of 7.96%. The proposed method enables the unambiguous identification and quantitation of glimepiride for pharmacokinetic, bioavailability or bioequivalence studies. 相似文献
7.
Jönsson BA Malmberg B Amilon A Helene Garde A Orbaek P 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2003,784(1):63-68
The aim of this work was to develop a method for determination of cortisol in saliva by liquid chromatography-tandem mass spectrometry (LC-MS-MS). Saliva was sampled on Salivette tubes. These were centrifuged, deuterium-labeled cortisol was added as internal standard and the proteins precipitated by acetonitrile. The supernatant was evaporated, dissolved in methanol acidified with acetic acid and analyzed by LC-MS-MS. The with-in run precision, tested by pooling saliva samples from volunteers and then analyzing these in a single run, was found to be 7% at 0.7 microgram l(-1). The between-run precision was tested by analysis of the same samples at different days and found to be 11% at 2.5 microgram l(-1). The limit of quantification was 0.5 microgram l(-1). The method was applied for analysis of saliva samples from three volunteers during their last week before vacation and the first and second week on vacation. In addition, the method was compared to analysis by an immunological method. The values from the immunological method were 2.7 times higher than the LC-MS-MS results. 相似文献
8.
Weng W Xu H Huang J Wang G Shen T Zhang J 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2005,816(1-2):315-320
A sensitive and specific high-performance liquid chromatography (HPLC)-electrospray ionization tandem mass spectrometry (MS-MS) was developed for the determination of bulleyaconitine A (BLA) in human plasma. BLA and internal standard (I.S.) ketoconazole were extracted from the plasma by a liquid-liquid extraction. The supernatant was evaporated to complete dryness and reconstituted with acetonitrile containing 0.1% acetic acid before injecting into an ODS MS column. The gradient mobile phase was composed of a mixture of acetonitrile (containing 0.1% acetic acid, v/v) and 0.1% acetic acid aqueous solution eluted at 0.3 ml/min. BLA and I.S. were determined by multiple reaction monitoring using precursor-->product ion combinations at m/z 644.6-->584.3 and 531.2-->81.6, respectively. Linearity was established for the concentration range of 0.12-6 ng/ml. The recoveries of BLA ranged from 96.93 to 113.9% and the R.S.D. was within 20%. The method is rapid and applicable to the pharmacokinetic studies of BLA in human. 相似文献
9.
Minkin P Zhao M Chen Z Ouwerkerk J Gelderblom H Baker SD 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2008,874(1-2):84-88
A rapid, sensitive and specific method was developed and validated using LC/MS/MS for determination of sunitinib in human plasma. Sample preparation involved a liquid-liquid extraction by the addition of 0.2mL of plasma with 4.0mL tert-butyl-methyl-ether extraction solution containing 25ng/mL of the internal standard clozapine. Separation of compounds was achieved on a C18 (50mmx2.1mm i.d., 3.5microm) analytical column using a mobile phase consisting of acetonitrile/H20 (65:35, v/v) containing 0.1% formic acid and isocratic flow at 0.150mL/min for 3min. The analytes were monitored by tandem-mass spectrometry with electrospray positive ionization. Linear calibration curves in human plasma were generated over the range of 0.2-500ng/mL with values for the coefficient of determination of >0.9950. Within- and between day precision and accuracy were < or =10%. The method was applied to the quantitation of sunitinib in plasma samples from a patient receiving daily oral therapy with sunitinib. 相似文献
10.
Determination of tetrabromobisphenol A in human serum by liquid chromatography-electrospray ionization tandem mass spectrometry 总被引:1,自引:0,他引:1
Hayama T Yoshida H Onimaru S Yonekura S Kuroki H Todoroki K Nohta H Yamaguchi M 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2004,809(1):131-136
A method for the determination of tetrabromobisphenol A (TBBPA) in human serum utilizing solid-phase extractions (SPEs) and liquid chromatography (LC) with electrospray ionization tandem MS (MS/MS) has been developed. After purification and concentration of TBBPA using consecutive SPEs on reversed-phase and normal-phase cartridges, the serum sample was subjected to LC. TBBPA was separated on a C18 reversed-phase column by gradient elution with a mixture of water, methanol, and acetonitrile as the mobile phase, and then detected with electrospray ionization MS/MS in negative ion mode. 13C12-TBBPA was suitable as an internal standard for the reproducible determination of TBBPA in human serum samples (5 g). The method has been validated in TBBPA concentration range of 5-100 pg per g serum, and the recoveries in the concentration range were higher than 83.3%. The repeatabilities of the proposed method of non-spiked control serum (6.3 pg per g serum) and spiked serum (added 5-100 pg per g serum) were within 10.0% as relative standard deviations. The limit of quantification (LOQ) for TBBPA was 4.1 pg per g serum, which was corresponded to 0.63 fmol on column. 相似文献
11.
Harri M Kasai H Mori T Tornaeus J Savela K Peltonen K 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,853(1-2):242-246
8-hydroxy-2'-deoxyguanosine (8-OHdG) is a widely used biomarker of oxidative stress in research related to DNA, protein damage as well as lipid peroxidation. HPLC-MS/MS with electrospray ionization (ESI) and the use of isotopically labelled 8-OHdG as an internal standard allows a simple quantification of 8-OHdG in urine samples. HPLC separation utilized the peak cutting technique and a 1.5 mmx120 mm analytical anion exchange column. Novel method entails only minimal sample handling including the addition of a buffer and an internal standard followed by centrifugation before the samples are ready for analysis. The levels of 8-OHdG in human urine samples (n=246) varied from 0.16 to 16.48 microg/L and the corresponding creatinine-normalized values were ranged from 0.49 to 14.27 microg of 8-OHdG/g creatinine. The correlation between the developed HPLC-MS/MS method and the existing HPLC-EC method was good with an R2 value of 0.8707. 相似文献
12.
Kollroser M Schober C 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2002,766(2):219-226
A sensitive and specific high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS-MS) method has been developed for the simultaneous determination of amiodarone and desethylamiodarone in human plasma. After the addition of the internal standard tamoxifen, plasma samples were extracted using Oasis MCX solid-phase extraction cartridges. The compounds were separated on a 5 microm Symmetry C18 (Waters) column (150 x 3.0 mm, internal diameter) with a mobile phase of acetonitrile-0.1% forrmic acid (46:54, v/v) at a flow-rate of 0.5 ml/min. The overall extraction efficiency was more than 89% for both compounds. The assay was sensitive down to 1 microg/l for amiodarone and down to 0.5 microg/l for desethylamiodarone. Within-run accuracies for quality-control samples were between 95 and 108% of the target concentration, with coefficients of variation <8%. The proposed method enables the unambiguous identification and quantitation of amiodarone and desethylamiodarone in both clinical and forensic specimens. 相似文献
13.
Paul J Taylor Anthony G Johnson 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1998,718(2):1159
We report here a quantitative method for the analysis of sirolimus in blood using solid-phase sample preparation and HPLC–electrospray-tandem mass spectrometry detection. Blood samples (500 μl) were prepared by pre-treatment with acetonitrile: 15 mM zinc sulphate (70:30, v/v), containing 32-demethoxysirolimus (internal standard) and C18 solid-phase extraction. The electrospray conditions were chosen to enhance the [M+NH4]+ species at the expense of other species. Detection was by multiple reactant monitoring with the mass transitions m/z 931.8→864.6 and m/z 901.8→834.4 employed for sirolimus and the internal standard, respectively. The method was linear over the range 0.2 to 100.0 μg l−1. The accuracy and inter-day precision, over this concentration range, was 94.4% to 104.4% and 1.4% to 5.0%, respectively. The accuracy and total precision at the limit of quantitation (0.2 μg l−1) was 103.0% and 10.8%, respectively. The mean absolute recovery of sirolimus and the internal standard were 80.5% and 81.3%, respectively. The sensitivity and analytical concentration range of the method make it suitable for therapeutic drug monitoring and pharmacokinetic studies. Further, the ability of the method to measure parent drug specifically will facilitate the evaluation of immunoassays for sirolimus. 相似文献
14.
Xiao W Chen B Yao S Cheng Z 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2005,817(2):153-158
An analytical method for simultaneous determination of erythromycin propionate and its active metabolite, erythromycin base, in human plasma by high-performance liquid chromatography-electrospray mass spectrometry (HPLC-ESI-MS) was developed and validated. Roxithromycin was selected as the internal standard. The samples were directly injected after simple deproteinized procedure only. The separation was achieved on a Johnson Spherigel analytical column packed with 5 microm C18 silica, employing acetonitrile -0.1% formic acid aqueous solution (50:50) as mobile phase. The quantification of target compounds was obtained by using a selected ion monitoring (SIM) at m/z 790.7 for erythromycin propionate, m/z 734.7 for erythromycin base and m/z 837.8 for roxithromycin. The correlation coefficients of the calibration curves were better than 0.997 (n=6), in the ranges from 2 ng/ml to 1 microg/ml, and from 1 to 10 microg/ml for erythromycin propionate and base. The method can provide the necessary sensitivity, precision and accuracy to allow the simultaneous determination of both compounds in a patient's plasma following a single administration of erythromycin stinoprate capsule (500 mg erythromycin base equivalent). 相似文献
15.
Zhao M Rudek MA He P Hartke C Gore S Carducci MA Baker SD 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2004,813(1-2):81-88
5-Azacytidine (5AC), a nucleoside analogue and hypomethylating agent, has anticancer properties and has been utilized in the treatment of various malignancies. 5AC is unstable and rapidly hydrolyzed to several by-products, including 5-azacytosine and 5-azauracil. A sensitive, reliable method was developed to quantitate 5AC using LC/MS/MS to perform pharmacokinetic and pharmacodynamic studies on 5AC combination therapy trials. Blood samples were collected in a heparinized tube and immediately processed for storage. To increase the stability of 5AC in plasma, 25 ng/mL tetrahydrouridine was added to the plasma and snap frozen. Plasma samples were extracted using acetonitrile then cleaned up by Oasis MCX ion exchange solid-phase extraction cartridges. 5AC was separated on an YMC Jsphr M80 C(18) column with gradient elution of ammonium acetate (2 mM) with 0.1% formic acid and methanol mobile phase. 5AC elutes at 5.0 +/- 0.2 min with a total run time of 30 min. Identification was through positive-ion mode and multiple reaction monitoring mode at m/z+ 244.9-->113.0 for 5AC and m/z+ 242.0-->126.0 for 5-methyl-2'-deoxycytidine, the internal standard. The lower limit of quantitation of 5AC was 5 ng/mL in human plasma, and linearity was observed from 5 to 500 ng/mL fitted by linear regression with 1/x weight. This method is 50 times more sensitive than previously published assays and successfully allows studies to characterize the pharmacokinetics and pharmacodynamics of 5AC. 相似文献
16.
Determination of nitrofuran metabolites in milk by liquid chromatography-electrospray ionization tandem mass spectrometry 总被引:1,自引:0,他引:1
Rodziewicz L 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2008,864(1-2):156-160
An LC-ESI-MS-MS method for the analysis of metabolites of four nitrofurans (furazolidone, furaltadone, nitrofurazone and nitrofurantoin) in raw milk has been developed. The samples were achieved by hydrolysis of the protein-bound drug metabolites, derivatization with 2-nitrobenzaldehyd (2-NBA) and clean-up extraction liquid-liquid with ethyl acetate. LC separation was achieved by using a Phenomenex Luna C-18 column. The mass spectrometer operated in multiple reaction monitoring mode (MRM) with positive electro-spray interface (ESI). The method validation was done according to the criteria laid down in Commission Decision No. 2002/657 EC. The validation includes the determination of linearity, repeatability, within-laboratory reproducibility, accuracy, decision limit (CCalpha) and detection capability (CCbeta). The calibration curves were linear, with typical (R(2)) values higher than 0.991. The coefficient of variation (CV, %) was lower than 9.3% and the accuracy (RE, %) ranged from -9.0% to 7.0%. CV within-laboratory reproducibility was lower than 13%. The limits of decision (CCalpha) and detection capability (CCbeta) were 0.12-0.29 microg/kg and 0.15-0.37 microg/kg, thus below the minimum required performance limit (MRPL) set at 1 microg/kg by the UE. This validated method was successfully applied for the determination of nitrofuran metabolites in a large number of milk samples. 相似文献
17.
Determination of bile acids in biological fluids by liquid chromatography-electrospray tandem mass spectrometry 总被引:7,自引:0,他引:7
A simple, sensitive, and specific liquid chromatography-electrospray tandem mass spectrometry (LC-MS/MS) method for the determination of bile acids in human bile has been developed. The bile acids were extracted with a C(18) (octadecyl) reversed-phase column and identified and quantified by simultaneous monitoring of their parent and daughter ions, using the multiple reaction monitoring mode. Identification and quantification of conjugated bile acids in bile was achieved in 5 min. The detection limit was 1 ng, and the determination was linear for concentrations up to 100 ng. The percent recovery of standards made of single conjugated (glycine and taurine) bile acid or of mixture of glycine- or taurine-conjugated cholic acid, chenodeoxycholic acid, deoxycholic acid, ursodeoxycholic acid, and lithocholic acid averaged 71.73% to 95.92%. The percent recovery of the same standard bile acids was also determined by gas chromatography-mass spectrometry (GC-MS), using the selected ion monitoring mode, and averaged 66% to 96%. A biliary bile acid profile of human gallbladder bile was obtained by LC-MS/MS and GC-MS.The results showed a good correlation between the two techniques and no significant differences between the two methods were observed. The LC-MS/MS method was also used for the analysis of serum, urine, and fecal bile acids. In conclusion, LC-MS/MS is a simple, sensitive, and rapid technique for the analysis of conjugated bile acids in bile and other biological samples. - Perwaiz, S., B. Tuchweber, D. Mignault, T. Gilat, and I. M. Yousef. Determination of bile acids in biological fluids by liquid chromatography-electrospray tandem mass spectrometry. J. Lipid Res. 2001. 42: 114;-119. 相似文献
18.
Highly sensitive determination of estrone and estradiol in human serum by liquid chromatography-electrospray ionization tandem mass spectrometry 总被引:1,自引:0,他引:1
A highly sensitive and specific quantification method of estrone and estradiol in human serum was described based upon the use of picolinoyl derivatization and liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) in a positive mode. Estrogens were treated with picolinoyl chloride hydrochloride or picolinic acid and 2-methyl-6-nitrobenzoic anhydride followed by a solid-phase extraction with ODS cartridge. Picolinoyl derivatization proceeded quantitatively even in a microscale, and the picolinoyl esters provided simple positive ESI-mass spectra showing [M+H](+) as base peaks for these estrogens. The picolinoyl derivatives of these estrogens showed 100-fold higher detection response compared to underivatized intact molecules by LC-ESI-MS (selected reaction monitoring). Using this derivatization, estrogens spiked in the charcoal treated human serum samples were analyzed with limit of quantification (LOQ), intra-day accuracy and precision of 1.0pg/ml, 96.0% and 9.9% for estrone, and 0.5pg/ml, 84.4% and 12.8% for estradiol, respectively. Estrone and estradiol added to the crude serum samples were recovered with comparable LOQ and accuracy obtained for the charcoal treated serum samples as well. 相似文献
19.
Zhu J Zhou X Zheng H Li Z 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2006,840(2):124-131
An analytical method was developed for the determination of enantiomers of dencichine in plasma. Sample extraction from plasma was achieved by a solid-phase extraction (SPE) procedure using a C(18) cartridge, with carbocisteine as the internal standard. Plasma was deproteinized using inorganic acid and derivatizated before the SPE. Chiral separation of dencichine enantiomers was achieved by pre-column derivatization using o-phthaldialdehyde (OPA) and the chiral thiol N-isobutanoyl-L-cysteine (NIBC) to form diastereoisomeric isoindole derivatives that were separable by ODS column using a gradient solvent programme. The column eluent was monitored using mass spectrometry (MS). The conditions of MS detection were optimized, and selected ion monitoring was used to selectively detect D-dencichine and its arrangement isomer. High sensitivity and selectivity were obtained using this method. The limit of detection was determined to be 10 ng/ml for D-dencichine and 8 ng/ml for L-dencichine in plasma. The linearity was demonstrated over a wide range of concentrations, from 0.5 to 50 microg/ml for both enatiomers. The intra- and inter-day precision (C.V.), studied at four concentrations, was less than 7.0%. No interferences from endogenous amino acids and isomers of dencichine were found. The method was suitable for pharmacokinetic studies of dencichine enantiomers. 相似文献
20.
Felodipine quantification in human plasma by high-performance liquid chromatography coupled to tandem mass spectrometry 总被引:2,自引:0,他引:2
Migliorança LH Barrientos-Astigarraga RE Schug BS Blume HH Pereira AS De Nucci G 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2005,814(2):217-223
A rapid, sensitive, robust and specific method was developed for the determination and quantitation of felodipine, in human blood plasma by liquid chromatography coupled with tandem mass spectrometry using nimodipine as internal standard. Felodipine was extracted from 0.5 mL human plasma by use of a liquid/liquid procedure using diethyl ether/hexane (80/20, v/v) as eluent. The method included a chromatographic run of 5 min using a C(18) analytical column (100 mm x 4.6 mm i.d.) and the calibration curve was linear over the range from 0.02 to 10 ng mL(-1) (r(2) > 0.994). The between-run precision, determined as relative standard deviation of replicate quality controls, was 5.7% (0.06 ng mL(-1)), 7.1% (0.6 ng mL(-1)) and 6.8% (7.5 ng mL(-1)). The between-run accuracy was +/- 0.0, 2.1 and 3.1% for the above-mentioned concentrations, respectively. 相似文献