首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The options available for processing quantitative data from isotope coded affinity tag (ICAT) experiments have mostly been confined to software specific to the instrument of acquisition. However, recent developments with data format conversion have subsequently increased such processing opportunities. In the present study, data sets from ICAT experiments, analysed with liquid chromatography/tandem mass spectrometry (MS/MS), using an Applied Biosystems QSTAR Pulsar quadrupole-TOF mass spectrometer, were processed in triplicate using separate mass spectrometry software packages. The programs Pro ICAT, Spectrum Mill and SEQUEST with XPRESS were employed. Attention was paid towards the extent of common identification and agreement of quantitative results, with additional interest in the flexibility and productivity of these programs. The comparisons were made with data from the analysis of a specifically prepared test mixture, nine proteins at a range of relative concentration ratios from 0.1 to 10 (light to heavy labelled forms), as a known control, and data selected from an ICAT study involving the measurement of cytokine induced protein expression in human lymphoblasts, as an applied example. Dissimilarities were detected in peptide identification that reflected how the associated scoring parameters favoured information from the MS/MS data sets. Accordingly, there were differences in the numbers of peptides and protein identifications, although from these it was apparent that both confirmatory and complementary information was present. In the quantitative results from the three programs, no statistically significant differences were observed.  相似文献   

2.
We report an ultrahigh-performance liquid chromatography tandem mass spectrometry (UHPLC–MS/MS) method to quantify all-trans-retinal in biological samples of limited size (15–35 mg), which is especially advantageous for use with adipose. To facilitate recovery, retinal and the internal standard 3,4-didehydroretinal were derivatized in situ into their O-ethyloximes. UHPLC resolution combined with high sensitivity and specificity of MS/MS allowed quantification of retinal-O-ethyloximes with a 5-fmol lower limit of detection and a linear range from 5 fmol to 1 pmol. This assay revealed that extraocular concentrations of retinal range from approximately 2 to 40 pmol/g in multiple tissues—the same range as all-trans-retinoic acid. All-trans-retinoic acid has high affinity (kd ? 0.4 nM) for its nuclear receptors (RARα, -β, and -γ), whereas retinal has low (if any) affinity for these receptors, making it unlikely that these retinal concentrations would activate RAR. We also show that the copious amount of vitamin A used in chow diets increases retinal in adipose depots 2- to 5-fold relative to levels in adipose of mice fed a vitamin A-sufficient diet, as recommended for laboratory rodents. This assay also is proficient for quantifying conversion of retinol into retinal in vitro and, therefore, provides an efficient method to study metabolism of retinol in vivo and in vitro.  相似文献   

3.
The tissue distribution of folate in its numerous coenzyme forms may influence the development of disease at different sites. For instance, the susceptibility of human colonic mucosa to localized folate deficiency may predispose to the development of colorectal cancer. We report a sensitive and robust ultra high-performance liquid chromatography (UHPLC) tandem mass spectrometry method for quantifying tissue H4folate, 5-CH3-H4folate, 5-CHO-H4folate, folic acid, and 5,10-CH+-H4folate concentration. Human colonic mucosa (20–100 mg) was extracted using lipase and conjugase enzyme digestion. Rapid separation of analytes was achieved on a UHPLC 1.9-μm C18 column over 7 min. Accurate quantitation was performed using stable isotopically labeled (13C5) internal standards. The instrument response was linear over physiological concentrations of tissue folate (R2 > 0.99). Limits of detection and quantitation were less than 20 and 30 fmol on column, respectively, and within- and between-run imprecision values were 6–16%. In colonic mucosal samples from 73 individuals, the average molar distribution of folate coenzymes was 58% 5-CH3-H4folate, 20% H4folate, 18% formyl-H4folate (sum of 5-CHO-H4folate and 5,10-CH+-H4folate), and 4% folic acid. This assay would be useful in characterizing folate distribution in human and animal tissues as well as the role of deregulated folate homeostasis on disease pathogenesis.  相似文献   

4.
Proteomic analyses of the proliferative and secretory phases of the human endometrium were carried out to identify proteins and discover differentially expressed proteins using isotope-coded affinity tags, three stages of chromatographic separation and online tandem mass spectrometry (MS/MS). From an initial list of 346 proteins identified by ProICAT, manual inspection of MS/MS spectra and confirmatory searches pared the list down to 119 positively identified proteins. Only five of the proteins showed consistent differential expression. The utility of some of these proteins as indicators of true differential expression in the endometrium is open to discussion. The two proteins with unquestionable differential expressions in the secretory endometrium are: glutamate NMDA receptor subunit zeta 1 precursor and FRAT1. Some of the proteins that show no differential expression have previously been examined in gene-expression studies with similar conclusions.  相似文献   

5.
J Liu  Y Liu  M Gao  X Zhang 《Proteomics》2012,12(14):2258-2270
A facile proteomic quantification method, fluorescent labeling absolute quantification (FLAQ), was developed. Instead of using MS for quantification, the FLAQ method is a chromatography-based quantification in combination with MS for identification. Multidimensional liquid chromatography (MDLC) with laser-induced fluorescence (LIF) detection with high accuracy and tandem MS system were employed for FLAQ. Several requirements should be met for fluorescent labeling in MS identification: Labeling completeness, minimum side-reactions, simple MS spectra, and no extra tandem MS fragmentations for structure elucidations. A fluorescence dye, 5-iodoacetamidofluorescein, was finally chosen to label proteins on all cysteine residues. The fluorescent dye was compatible with the process of the trypsin digestion and MALDI MS identification. Quantitative labeling was achieved with optimization of reacting conditions. A synthesized peptide and model proteins, BSA (35 cysteines), OVA (five cysteines), were used for verifying the completeness of labeling. Proteins were separated through MDLC and quantified based on fluorescent intensities, followed by MS identification. High accuracy (RSD% < 1.58) and wide linearity of quantification (1-10(5) ) were achieved by LIF detection. The limit of quantitation for the model protein was as low as 0.34 amol. Parts of proteins in human liver proteome were quantified and demonstrated using FLAQ.  相似文献   

6.
Sulfonyl chlorides substituted with functional groups having high proton affinity can serve as derivatization reagents to enhance the sensitivity for steroidal estrogens in liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). The most commonly used reagent for derivatization of estrogens for LC-ESI-MS/MS is dansyl chloride. In this study, we compared dansyl chloride, 1,2-dimethylimidazole-4-sulfonyl (DMIS) chloride, pyridine-3-sulfonyl (PS) chloride, and 4-(1H-pyrazol-1-yl)benzenesulfonyl (PBS) chloride for derivatization of 17beta-estradiol (E2) prior to LC-ESI-MS/MS. The product ion spectra of the dansyl and DMIS derivatives were dominated by ions representing derivatization reagent moieties. In contrast, the product ion spectrum of the PS derivative of E2 and, to a lesser extent, the PBS derivative, showed analyte-specific fragment ions. Derivatization with PS chloride was therefore chosen for further investigation. The product ion spectrum of the PS derivative of E2 showed intense ions at m/z 272, assigned to the radical E2 cation, and at m/z 350, attributed to the loss of SO(2) from the [M+H](+) ion. Third-stage mass spectrometry of the PS derivative of E2 with isolation and collisional activation of the m/z 272 ion resulted in steroid C and D ring cleavages analogous to those observed in electron ionization mass spectrometry. The product ion spectra of the PS derivatives of estrone, 17alpha-ethinylestradiol, equilin, and equilenin showed similar estrogen-specific ions. Using derivatization with PS chloride, we developed an LC-ESI-MS/MS method with multiple reaction monitoring of primary and confirmatory precursor-to-product ion transitions for the determination of E2 in serum.  相似文献   

7.
8.
We describe a liquid chromatography (LC) tandem mass spectrometry (MS-MS) method for the determination of 5-methyltetrahydrofolic acid (5-methylTHF) and folic acid concentrations and enrichments in human plasma. It was used to study absorption and initial metabolism in five volunteers with two simultaneously administered oral test doses ([(13)C(6)]folic acid in capsules and [(2)H(2)]folic acid in a drink). [(13)C(5)]5-methylTHF and [(2)H(4)]folic acid were used as internal standards. Plasma samples (2 ml) were purified using folate binding protein affinity columns, followed by a concentration step. After LC separation, folates were detected using positive electrospray ionization MS-MS under multiple reaction monitoring conditions. Calibrations were linear for 5-methylTHF over the range 1.2 x 10(-11) (=limit of detection) to 3.2 x 10(-7)mol/L and for folic acid over the range 5 x 10(-10) (=limit of detection) to 4.5 x 10(-8)mol/L. For 5-methylTHF concentration in plasma, intraassay coefficient of variation was within 8.6% (and for unlabeled 5-methylTHF it was within 2.8%) and interassay coefficient of variation was within 9.0%. For folic acid concentrations these coefficient of variations were within 7.5% and within 6.5%, respectively. The [(13)C(6)] and [(2)H(2)] isotopomers of folic acid and 5-methylTHF were measured in the plasma of each volunteer for 8h. After accounting for the time delay due to capsule opening, the modeling results showed no significant differences in absorption time, first pass effect, and elimination rate in the folic acid test doses in capsule or drink. We conclude that LC-MS-MS offers increased sensitivity for quantification of plasma concentrations and enrichments of 5-methylTHF and folic acid and is applicable to stable-isotope studies in humans.  相似文献   

9.
Human saliva contains a large number of proteins and peptides (salivary proteome) that help maintain homeostasis in the oral cavity. Global analysis of human salivary proteome is important for understanding oral health and disease pathogenesis. In this study, large-scale identification of salivary proteins was demonstrated by using shotgun proteomics and two-dimensinal gel electrophoresis-mass spectrometry (2-DE-MS). For the shotgun approach, whole saliva proteins were prefractionated according to molecular weight. The smallest fraction, presumably containing salivary peptides, was directly separated by capillary liquid chromatography (LC). However, the large protein fractions were digested into peptides for subsequent LC separation. Separated peptides were analyzed by on-line electrospray tandem mass spectrometry (MS/MS) using a quadrupole-time of flight mass spectrometer, and the obtained spectra were automatically processed to search human protein sequence database for protein identification. Additionally, 2-DE was used to map out the proteins in whole saliva. Protein spots 105 in number were excised and in-gel digested; and the resulting peptide fragments were measured by matrix-assisted laser desorption/ionization-mass spectrometry and sequenced by LC-MS/MS for protein identification. In total, we cataloged 309 proteins from human whole saliva by using these two proteomic approaches.  相似文献   

10.
An ultra-performance liquid chromatography tandem mass spectrometry (UPLC™–MS/MS) assay was developed for the simultaneous analysis of histamine, its major metabolite tele-methylhistamine, and an internal standard (N-tele-(R)-α-dimethylhistamine) from human cerebrospinal fluid (CSF) samples. The method involves derivatization of primary amines with 4-bromobenzenesulfonyl chloride and subsequent analysis by reversed phase liquid chromatography with mass spectrometry detection and positive electrospray ionization. The separation of derivatized biogenic amines was achieved within 3.5 min on an Acquity® BEH C18 column by elution with a linear gradient of acetonitrile/water/formic acid (0.1%). The assay was linear in the concentration range of 50–5000 pM for each amine (5.5–555 pg/ml for histamine and 6.25–625 pg/ml for tele-methylhistamine). For repeatability and precision determination, coefficients of variation (CVs) were less than 11.0% over the tested concentration ranges, within acceptance criteria. Thus, the developed method provides the rapid, easy, highly sensitive, and selective requirement to quantify these amines in human CSF. No significant difference was found in the mean ± standard error levels of these amines between a group of narcoleptic patients (histamine = 392 ± 64 pM, tele-methylhistamine = 2431 ± 461 pM, n = 7) and of neurological control subjects (histamine = 402 ± 72 pM, tele-methylhistamine = 2209 ± 463 pM, n = 32).  相似文献   

11.
The identification and characterization of proteins in complex biological samples such as body fluids, require powerful and reliable tools. Mass spectrometry is today one of the most important methods in such research. This paper reports on the results from the first experiment where a tryptic digest of cerebrospinal fluid was analyzed applying reversed phase liquid chromatography coupled on-line to a 9.4 T Fourier transform ion cyclotron resonance mass spectrometer. In total, 70 204 peaks were detected, which originated from 16 296 isotopic clusters corresponding to 6551 unique peptide masses. From these masses, 39 proteins were identified in the sample. The amount of sample required for one experiment corresponds to 32 microL of cerebrospinal fluid.  相似文献   

12.
Here we report a new isotopic pair of derivatization reagents, ω-bromoacetonylquinolinium bromide (BQB) and d7-ω-bromoacetonylquinolinium bromide (d7-BQB). BQB and d7-BQB both rapidly and selectively reacted with thiols in acidic medium within 3 min with the aid of a microwave. Reduced thiols and total thiols in urine were labeled with BQB and d7-BQB, respectively. The BQB- and d7-BQB-labeled urine samples were then mixed and separated on a HILIC (hydrophilic interaction chromatography) column followed by electrospray ionization tandem mass spectrometry (ESI–MS/MS) detection. The new strategy, which we have named isotope differential derivatization, allows us to simultaneously determine thiols and oxidized thiols in a single run. Compared with positive mode ESI detection of unlabeled thiols, the positive mode ESI–MS signal intensities of BQB-labeled thiols were found to increase by 10-, 20-, and 40-fold for cysteine (Cys), homocysteine (HCys), and glutathione (GSH), respectively (unlabeled N-acetylcysteine (Nac) is difficult to detect by ESI–MS in positive mode due to its low ionization efficiency). The detection limits calculated at a signal-to-noise ratio of 3 were found to be 8.02, 1.56, 0.833, and 3.27 nmol/L for Cys, HCys, Nac, and GSH, respectively. Recoveries of thiols and disulfides from spiked urine samples were between 80% and 105%. The method was successfully used to determine thiols and oxidized thiols in urine samples of 25 healthy volunteers.  相似文献   

13.
Quantitative protein profiling is an essential part of proteomics and requires technologies that accurately, reproducibly, and comprehensively identify and quantify proteins. Over the past years, many quantitative proteomic methods have been developed. Here, 20S proteasome subtypes isolated from rat were compared by four approaches based on the combination of isotope-coded affinity tag (ICAT), 2-DE, LC and ESI and MALDI MS: (i) 2-DE, (ii) ICAT/2-DE MALDI-MS, (iii) ICAT/LC-ESI-MS, (iv) ICAT/LC-MALDI-MS. A definite qualitative advantage of 2-DE gels was the separation of all known protein species, the identification of cysteine sulfoxide of alpha-4 (RC6-IS) and N-terminal acetylation of several subunits. Furthermore, quantitative differences between the standard subunits beta-2, and beta-5 and their immunosubunits were only detected by 2-DE image analysis revealing a higher replacement of standard- by immuno-beta-subunits in subtype IV. It was obvious that for relative quantification only protein spot and mass peaks with a certain level of intensity displayed acceptable values of SD. However, ICAT in conjunction with LC/MALDI-MS was the most accurate method for quantification. The experimental data of this investigation are accessible via http://www.mpiib-berlin.mpg.de/2D-PAGE/.  相似文献   

14.
Evaluation of cellular processes and their changes at the level of protein expression and post-translational modifications may allow identification of novel proteins and the mechanisms involved in pathogenic processes. However, the number of proteins and, after tryptic digestion, of peptides from a single cell can be tremendously high. Separation and analysis of such complex peptide mixtures can be performed using multidimensional separation techniques such as two-dimensional gel electrophoresis or two-dimensional-high-performance liquid chromatography (2-D-HPLC). The aim of this work was to establish a fully automated on-line 2-D-HPLC separation method with column switching for the separation of complex tryptic digests. A model mixture of five proteins as well as a nuclear matrix protein sample were digested with trypsin and separated using a strong cation exchange (SCX) column in the first dimension and nano reversed phase in the second dimension. Separated peptides were detected using an ion trap mass spectrometer. The advantages of this new fully automated method are rapid sample loading, the possibility of injecting large volumes and no introduction of salt into the mass spectrometer. Furthermore, column switching allows the independent control and optimization of the two dimensions independently.  相似文献   

15.
We developed and validated a rapid, sensitive, and specific liquid chromatography tandem mass spectrometry (LC–MS/MS) method for determination of global DNA methylation in tissue. DNA was extracted by phenol–chloroform, hydrolyzed using 88% formic acid at 140 °C, spiked with cytosine-2,4-13C15N2 as internal standard, evaporated under nitrogen, reconstituted in methanol, and analyzed by LC–MS/MS in multiple reaction monitoring mode to reflect the global DNA methylation of the tissue. The method was linear throughout the range of clinical interest and had good sensitivity, with a limit of quantification of 0.5 pg for both cytosine (Cyt) and 5-methylcytosine (5mCyt). The linear range of calibration curve was 1–50 and 1–100 ng/ml for 5mCyt and Cyt, respectively, with a correlation coefficient higher than 0.99. The relative standard deviation (RSD) was 0.70–4.09% and 0.60–4.81% for Cyt and 5mCyt, respectively. The intraday precision expressed as RSD ranged from 1.86% to 4.67%, whereas the interday values ranged from 3.72% to 4.68%. The recovery of the method varied from 86.52% to 105.14%. This yielded a simple and reliable LC–MS/MS assay for detection of Cyt and 5mCyt, thereby enabling the evaluation of global DNA methylation.  相似文献   

16.
17.
18.
The proteins secreted by prostate cancer cells (PC3(AR)6) were separated by strong anion exchange chromatography, digested with trypsin and analyzed by unbiased liquid chromatography tandem mass spectrometry with an ion trap. The spectra were matched to peptides within proteins using a goodness of fit algorithm that showed a low false positive rate. The parent ions for MS/MS were randomly and independently sampled from a log-normal population and therefore could be analyzed by ANOVA. Normal distribution analysis confirmed that the parent and fragment ion intensity distributions were sampled over 99.9% of their range that was above the background noise. Arranging the ion intensity data with the identified peptide and protein sequences in structured query language (SQL) permitted the quantification of ion intensity across treatments, proteins and peptides. The intensity of 101,905 fragment ions from 1421 peptide precursors of 583 peptides from 233 proteins separated over 11 sample treatments were computed together in one ANOVA model using the statistical analysis system (SAS) prior to Tukey-Kramer honestly significant difference (HSD) testing. Thus complex mixtures of proteins were identified and quantified with a high degree of confidence using an ion trap without isotopic labels, multivariate analysis or comparing chromatographic retention times.  相似文献   

19.
Understanding the intricate metabolic processes involved in plant cell wall biosynthesis is limited by difficulties in performing sensitive quantification of many involved compounds. Hydrophilic interaction liquid chromatography is a useful technique for the analysis of hydrophilic metabolites from complex biological extracts and forms the basis of this method to quantify plant cell wall precursors. A zwitterionic silica-based stationary phase has been used to separate hydrophilic nucleotide sugars involved in cell wall biosynthesis from milligram amounts of leaf tissue. A tandem mass spectrometry operating in selected reaction monitoring mode was used to quantify nucleotide sugars. This method was highly repeatable and quantified 12 nucleotide sugars at low femtomole quantities, with linear responses up to four orders of magnitude to several 100 pmol. The method was also successfully applied to the analysis of purified leaf extracts from two model plant species with variations in their cell wall sugar compositions and indicated significant differences in the levels of 6 out of 12 nucleotide sugars. The plant nucleotide sugar extraction procedure was demonstrated to have good recovery rates with minimal matrix effects. The approach results in a significant improvement in sensitivity when applied to plant samples over currently employed techniques.  相似文献   

20.
Ceruloplasmin has ferroxidase activity and plays an essential role in iron metabolism. In this study, a site-specific glycosylation analysis of human ceruloplasmin (CP) was carried out using reversed-phase high-performance liquid chromatography with electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). A tryptic digest of carboxymethylated CP was subjected to LC-ESI-MS/MS. Product ion spectra acquired data-dependently were used for both distinction of the glycopeptides from the peptides using the carbohydrate B-ions, such as m/z 204 (HexNAc) and m/z 366 (HexHexNAc), and identification of the peptide moiety of the glycopeptide based on the presence of the b- and y-series ions derived from the peptide. Oligosaccharide composition was deduced from the molecular weight calculated from the observed mass of the glycopeptide and theoretical mass of the peptide. Of the seven potential N-glycosylation sites, four (Asn119, Asn339, Asn378, and Asn743) were occupied by a sialylated biantennary or triantennary oligosaccharide with fucose residues (0, 1, or 2). A small amount of sialylated tetraantennary oligosaccharide was detected. Exoglycosidase digestion suggested that fucose residues were linked to reducing end GlcNAc in biantennary oligosaccharides and to reducing end and/or alpha1-3 to outer arms GlcNAc in triantennary oligosaccharides and that roughly one of the antennas in triantennary oligosaccharides was alpha2-3 sialylated and occasionally alpha1-3 fucosylated at GlcNAc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号