首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple chemiluminometric method using flow injection has been developed for the determination of laevodopa, based on its sensitizing effect on the weak chemiluminescence (CL) reaction between Na2SO3 and acidic KMnO4. Under optimum experimental conditions, the CL intensity was linearly related to the concentration of laevodopa from 3.4 × 10–8 to 2.4 × 10–5 mol/L and the detection limit was 1.1 × 10–8 mol/L (s:n = 3). The relative standard deviation (RSD) of the proposed method calculated from 20 replicate injection of 3 × 10–7 mol/L laevodopa was 3.3%. The correlation coefficient was 0.997. The method was successfully applied to the determination of laevodopa in commercial pharmaceutical formulations and spiked urine samples. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

2.
Based on the inhibition effect of transferrin (Tf) on the reaction of the luminol–hydrogen peroxide (H2O2) chemiluminescence (CL) system, catalysed by meso‐tetra‐(3‐methoxyl‐4‐hydroxyl) phenyl manganese porphyrin (MnP) as a mimetic enzyme of peroxides, a sensitive flow‐injection CL method has been developed for the determination of Tf in an alkaline medium. The CL reaction was carefully investigated by examining the variations of reaction conditions. Under optimum conditions, the linear range for the determination of transferrin was 0.04–20.0 μg/mL and the detection limit was 1.62 ng/mL. This proposed method was sensitive, convenient and simple, and has been successfully applied to the determination of transferrin in a serum sample. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

3.
It was found that meloxicam could enhance the chemiluminescence (CL) of the tris(2,2'‐bipyridine) ruthenium(II)–Ce(IV) system in the medium of sulfate acid. Based on this phenomenon a new flow‐injection system with chemiluminescent detection has been proposed for determination of meloxicam. Under optimum conditions, meloxicam had a good linear relationship with the CL intensity in the concentration range of 6.0  10?4 to 1.0 µg/mL and the detection limit was 3.7 × 10?4 µg/mL. The proposed method was applied to detect meloxicam in tablets and a satisfactory recovery was obtained. The possible mechanism for this CL system is also discussed in this paper. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
The main purpose of this study was to develop an inexpensive, simple, rapid and sensitive chemiluminescence (CL) method for the determination of glutamine (Gln) using a flow‐injection (FI) system. Gln was found to strongly inhibit the CL signal of the luminol–H2O2–CuSO4 system in Na2B4O7 solution. A new FI‐CL method was developed for the determination of Gln. Parameters affecting the reproducibility and CL detection were optimized systematically. Under the optimized conditions, the corresponding linear regression equation was established over the range of 5.0 × 10?7 to 2.5 × 10?6 mol/L with the detection limit of 1.8 × 10?8 mol/L. The relative standard deviation was found to be 1.8% for 11 replicate determinations of 1.5 × 10?6 mol/L Gln. The proposed method has been satisfactorily applied for the determination of Gln in real samples (Marzulene‐s granules) with recoveries in the range of 98.7–108.6%. The minimum sampling rate was about 100 samples/h. The possible mechanism of this inhibitory CL was studied by fluorescence spectrophotometer and UV–vis spectrophotometer. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

5.
A novel flow‐injection chemiluminescence method was developed for the selective determination of human immunoglobulin G (IgG) in the presence of thiomersal by changing the flow rates of peristaltic pump. The study was based on the independence and additivity of the CL signals of human IgG and thiomersal in the galangin–potassium permanganate–polyphosphoric acid system. In meantime, two equations relating to the concentrations of mixing solutions of human IgG and thiomersal vs the CL intensity were established and solved, on the basis of which the content of thiomersal included in samples was simultaneously determined too. The enhanced CL intensity was in proportion to concerntrations in the range 8.0 × 10?7 to 8.0 × 10?5 g/mL for human IgG and 1.0 × 10?7 to 2.0 × 10?6 g/mL for thiomersal with the detection limits of 5.0 × 10?7 g/mL for human IgG and 6.0 × 10?8 g/mL for thiomersal, respectively. The relative standard deviation for 1.0 × 10?5 g/mL human IgG was 0.8% and for 2.0 × 10?7 g/mL thiomersal it was 2.0% (n = 10). The proposed method was applied to determine three synthetic samples with recoveries of 91.5–109.5%. In addition, the possible chemiluminescence mechanisms are discussed as well. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

6.
A novel flow injection chemiluminescence method is proposed for determination of cholesterol in this paper. The cholesterol oxidase was immobilized onto sol–gel and prepared as an enzymatic reaction column. The determination of cholesterol was performed by quantitative determination of hydrogen peroxide produced from an enzymatic reaction. The luminol–H2O2–metal chelate diperiodatocuprate(III) system ensured that the method was highly sensitive and selective. Free cholesterol was determined over the range 5.0 × 10–8 mol/L–5.0 × 10–7 mol/L, with a limit of detection (3σ) of 1.9 × 10–8 mol/L. The relative standard deviation (RSD) for 2.5 × 10–7 mol/L was 2.7% (n = 7). The proposed method offered the advantages of sensitivity, selectivity, simplicity and rapidity for free cholesterol determination, and was successfully applied to the direct determination of free cholesterol in serum. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

7.
A simple and rapid flow‐injection chemiluminescence method has been developed for the determination of dithiocarbamate fungicide thiram based on the chemiluminescence reaction of thiram with ceric sulfate and quinine in aqueous sulfuric acid. The present method allowed the determination of thiram in the concentration range of 7.5–2500 ng/mL and the detection limit (signal‐to‐noise ratio = 3) was 7.5 ng/mL with sample throughput of 120/h. The relative standard deviation was 2.5% for 10 replicate analyses of 500 ng/mL thiram. The effects of foreign species including various anions and cations present in water at environmentally relevant concentrations and some pesticides were also investigated. The proposed method was applied to determine thiram in spiked natural waters using octadecyl bonded phase silica (C18) cartridges for solid‐phase extraction. The recoveries were in the range 99 ± 1 to 104 ± 1%. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
《Luminescence》2003,18(2):67-71
A flow injection method for the determination of glycerol using a co‐immobilized enzyme reactor containing glycerokinase and glycerol‐3‐phosphate oxidase is described. The hydrogen peroxide produced is monitored by using a luminol chemiluminescence reaction in the presence of catalyst such as Co(II). The detection limit (2.5 × blank noise) for glycerol is 7 × 10?3 mmol/L with a sample throughput of 40/h. The calibration graph is linear over the range studied (0.2–1.0 mmol/L) with relative standard deviation 1.2–2.4%. The method is applied to the determination of glycerol in blood serum produced off‐line from triglycerides using lipase isolated from bovine pancreas. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

9.
A sensitive and simple chemiluminescent (CL) method for the determination of clomipramine has been developed by combining the flow‐injection analysis (FIA) technique, which is based on the CL intensity generated from the redox reaction of potassium permanganate (KMnO4)–formic acid in sulphuric acid (H2SO4) medium. Under the optimum conditions, the linear range for the determination of clomipramine was 0.04–4 µg/mL, with a correlation coefficient of 0.9988 (n = 10) and a detection limit of 0.008 µg/mL (3σ), and the relative standard deviation (RSD) for 2.0 µg/mL clomipramine (n = 11) is 1.26%. The proposed method has been successfully applied to the determination of the studied clomipramine in pharmaceutical preparations. The possible reaction mechanism is discussed. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

10.
A simple and sensitive flow‐injection (FI) method for the determination of nitrate and nitrite in natural waters, based on luminol chemiluminescence (CL) detection, is reported. Nitrate was reduced online to nitrite via a copperized cadmium (Cu–Cd) column and then reacted with acidic hydrogen peroxide to form peroxynitrous acid. CL emission was observed from the oxidation of luminol in an alkaline medium in the presence of the peroxynitrite anion. The limits of detection (S:N = 3) were 0.02 and 0.01 µg N/L, with sample throughputs of 40 and 90 /h for nitrate and nitrite, respectively. Calibration graphs were linear over the range 0.02–50 and 0.01–50 µg N/L [R2 = 0.9984 (n = 8) and R2 = 0.9965 (n = 7)] for nitrate and nitrite, respectively, with relative standard deviations (RSDs; n = 3) in the range 1.8–4.6%. The key chemical and physical variables (reagent concentrations, buffer pH, flow rates, sample volume, Cu–Cd reductor column length) were optimized and potential interferences investigated. The effect of cations [Ca(II), Mg(II), Co(II), Fe(II) and Cu(II)] was masked online with EDTA. Common anions (PO43?, SO42? and HCO3?) did not interfere at their maximum admissible concentrations in freshwaters. The effect of salinity on the luminol CL reaction with and without nitrate and nitrite (2 and 0.5 µg N/L, respectively) was also investigated. The method was successfully applied to freshwaters and the results obtained were in good agreement with those obtained by an automated segmented flow analyser reference method. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

11.
Liquid‐core waveguides (LCWs), devices that constrain the emitted radiation minimizing losses during the transport, are an alternative to maximize the amount of detected radiation in luminescence. In this work, the performance of a LCW flow‐cell was critically evaluated for chemiluminescence measurements, by using as model the oxidation of luminol by hydrogen peroxide or hypochlorite. An analytical procedure for hypochlorite determination was also developed, with linear response in the range 0.2–3.8 mg/L (2.7–51 µmol/L), a detection limit estimated as 8 µg/L (0.64 µmol/L) at the 99.7% confidence level and luminol consumption of 50 µg/determination. The coefficients of variation were 3.3% and 1.6% for 0.4 and 1.9 mg/L ClO?, respectively, with a sampling rate of 164 determinations/h. The procedure was applied to the analysis of Dakin's solution samples, yielding results in agreement with those obtained by iodometric titration at the 95% confidence level. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

12.
A sensitive and simple flow‐injection chemiluminescence (FI‐CL) method, which was based on the CL intensity generated from the redoxreaction of potassium permanganate (KMnO4)–formaldehyde in vitriol (H2SO4) medium, has been developed, validated and applied for the determination of naphazoline hydrochloride and oxymetazoline hydrochloride. Besides oxidants and sensitizers, the effect of the concentration of H2SO4, KMnO4 and formaldehyde was investigated. Under the optimum conditions, the linear range was 1.0 × 10?2–7.0 mg/L for naphazoline hydrochloride and 5.0 × 10?2–10.0 mg/L for oxymetazoline hydrochloride. During seven repeated inter‐day and intra‐day precision tests of 0.1, 1.0 and 10.0 mg/L samples, the relative standard deviations all corresponded to reference values. The detection limit was 8.69 × 10?3 mg/L for naphazoline hydrochloride and 3.47 × 10?2 mg/L for oxymetazoline hydrochloride (signal‐to‐noise ratio ≤3). This method has been successfully implemented for the determination of naphazoline hydrochloride and oxymetazoline hydrochloride in pharmaceuticals. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

13.
Chemiluminescence (CL) detection for the determination of estrogen benzoate, using the reaction of tris(1,10–phenanthroline)ruthenium(II)–Na2SO3–permanganate, is described. This method is based on the CL reaction of estrogen benzoate (EB) with acidic potassium permanganate and tris(1,10–phenanthroline)ruthenium(II). The CL intensity is greatly enhanced when Na2SO3 is added. After optimization of the different experimental parameters, a calibration graph for estrogen benzoate is linear in the range 0.05–10 µg/mL. The 3 s limit of detection is 0.024 µg/mL and the relative standard deviation was 1.3% for 1.0 µg/mL estrogen benzoate (n = 11). This proposed method was successfully applied to commercial injection samples and emulsion cosmetics. The mechanism of CL reaction was also studied. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

14.
A new chemiluminescence (CL) reaction was observed when chloramphenicol solution was injected into the mixture after the end of the reaction of alkaline luminol and sodium periodate or sodium periodate was injected into the reaction mixture of chloramphenicol and alkaline luminol. This reaction is described as an order‐transform second‐chemiluminescence (OTSCL) reaction. The OTSCL method combined with a flow‐injection technique was applied to the determination of chloramphenicol. The optimum conditions for the order‐transform second‐chemiluminescence emission were investigated. A mechanism for OTSCL has been proposed on the basis of the chemiluminescence kinetic characteristics, the UV‐visible spectra and the chemiluminescent spectra. Under optimal experimental conditions, the CL response is proportional to the concentration of chloramphenicol over the range 5.0 × 10?7–5.0 × 10?5 mol/L with a correlation coefficient of 0.9969 and a detection limit of 6.0 × 10?8 mol/L (3σ). The relative standard deviation (RSD) for 11 repeated determinations of 5.0 × 10?6 mol/L chloramphenicol is 1.7%. The method has been applied to the determination of chloramphenicol in pharmaceutical samples with satisfactory results. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

15.
A semi‐micro flow injection analysis (SMFIA) method for evaluation of quenching effect of food additive antioxidants or health foods on peroxynitrite (ONOO) is described. The injected sample was carried with phosphate buffer containing NaNO2, mixed with a trigger solution to generate ONOO and then detected CL generated after mixing with luminol solution. Selective chemiluminescence caused by ONOO in this generation system was confirmed by catalase treatment. Ascorbic acid (ASA), Trolox and ascorbyl palmitate (ASP) were used as food additive antioxidants. EC50 values of ASA, Trolox and ASP were 2.6, 6.4 and 43 µg/mL, respectively. The amount of reagents required for an assay by this SMFIA system could reduce the time by a third compared with the conventional method previously reported. Furthermore, as an application of the proposed method, the quenching effect of commercially available Noni (Morinda citrifolia) juices was evaluated. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

16.
In this paper, a novel chemiluminescent (CL) method for the determination of benzhexol has been developed by combining the flow injection technique and its sensitizing effect on the weak CL reaction between sulfite and acidic cerium(IV). A mechanism for the CL reaction has been proposed on the basis of CL spectra. Under the optimized conditions, the proposed method allows the measurement of benzhexol hydrochloride over the range 0.1–10 μg/mL with a correlation coefficient of 0.9992 (n = 8), a detection limit of 0.02 μg/mL (3σ), and a relative standard deviation for 2.0 μg/mL benzhexol (n = 11) of 1.65%. The utility of this method was demonstrated by determining benzhexol hydrochloride in tablets. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

17.
A novel flow‐injection chemiluminescence (FI‐CL) method is described for the determination of 2‐methoxyestradiol (2‐ME). The method is based on the inhibitory effect of 2‐ME on the CL reaction of luminol and potassium ferricyanide in alkaline solution. Under optimal conditions, net CL intensity was proportional to 2‐ME concentration in synthetic and mouse plasma samples. Corresponding linear regression equations were 8.0 x 10‐9‐1.0 x 10‐7g/mL for synthetic samples and 2.0 x 10‐9‐1.0 x 10‐7g/mL for plasma samples. Detection limit for synthetic samples and limits for quantification of plasma samples were 8.4 x 10‐10g/mL (3σ) for synthetic samples and 4.0 x 10‐9g/mL for mouse samples. A complete analysis was performed for 60 s, including washing and sampling, resulting in a throughput of ≈ 60/h. The proposed method was applied for the determination of 2‐ME in synthetic and mouse plasma samples. Percentage recoveries were 101.0‐102.8% and 98.0‐105.0%, respectively. A possible mechanism responsible for CL reaction is proposed. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

18.
Bicyclic dioxetanes 2a–c bearing a 2′‐alkoxy‐2‐hydroxy‐1,1′‐binaphthyl‐7‐yl moiety were effectively synthesized and their base‐induced chemiluminescent decomposition was investigated by the use of alkaline metal (Na+ and K+) or Mg2+ alkoxide in MeOH. When 2a–c were treated with tetrabutylammonium fluoride (TBAF) in dimethyl sulfoxide (DMSO) as a reference system, they showed chemiluminescence as a flash of orange light (maximum wavelength λmaxCL = 573–577 nm) with efficiency ΦCL = 6–8 × 10–2. On the other hand, for an alkaline metal (Na+ or K+) alkoxide/MeOH system, 2a–c decomposed slowly to emit a glow of chemiluminescence, the spectra of which were shifted slightly toward red from the TBAF/DMSO system, and ΦCL (= 1.4–2.3 × 10–3) was considerably decreased. In addition, Mg(OMe)2 was found to play a characteristic role as a base for the chemiluminescent decomposition of 2a–c through coordination to the intermediary oxidoaryl‐substituted dioxetanes 13. Thus, Mg2+ increased ΦCL to more than twice those with Na+ or K+, while it shifted λmaxCL considerably toward blue (λmaxCL = 550–566 nm). Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

19.
A sensitive and convenient flow‐injection chemiluminescence (FI‐CL) turn‐on assay for alkaline phosphatase (ALP) activity without any label and synthesis is developed. Cu2+ can catalyze the luminol–H2O2 CL reaction. Pyrophosphate (PPi) can chelate Cu2+ and therefore the Cu2+‐mediated luminol‐H2O2 CL reaction is inhibited. The addition of ALP can catalyze the hydrolysis of PPi into phosphate ions, Cu2+ is released and the chemiluminescence recovers. A detection limit of 1 mU/mL ALP is obtained.  相似文献   

20.
A novel flow‐injection chemiluminescence method for the determination of melamine in urine and plasma was developed. It was found that melamine can remarkably enhance chemiluminescence emission from the luminol–K3Fe(CN)6 system in an alkaline medium. Under the optimum conditions, chemiluminescence intensity had a good linear relationship with the concentration of melamine in the range 9.0 × 10–9–7.0 × 10–6 g/mL, with a correlation coefficient of 0.9992. The detection limit (3σ) was 3.5 ng/mL. The method has been applied to determine the concentration of melamine in samples using liquid–liquid extraction. Average recoveries of melamine were 102.6% in urine samples and 95.1% in plasma samples. The method provided a reproducible and stable approach for the sensitive detection of melamine in urine and plasma samples. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号