INTRODUCTION: In previous studies we and others have demonstrated the usefulness of violet laser diodes (VLDs) as replacement laser sources for krypton-ion lasers on stream-in-air cytometers. Previously available VLDs had a maximum available power of less than 25 mW; this was sufficient for excitation of densely labeled cell surface antigens using fluorochromes such as Cascade Blue or Pacific Blue, but may have been insufficient for applications requiring higher levels of photon saturation, such as low-level expression of Cyan Fluorescent Protein (ECFP) in CFP-YFP FRET applications. In this follow-up study, we have tested more powerful VLDs emitting at 55 mW, and a beam-merged dual module VLD with 100 mW combined output, for their ability to excite a variety of violet-excited fluorochromes, including CFP. METHODS: A dual module VLD (two linear polarized VLDs with their beams merged by a polarized beam combiner) emitting at 404 nm was mounted on a BD FACSVantage DiVa stream-in-air cytometer. The individual polarized 55 mW beams or the 100 mW combined beams were used to analyze PBMCs labeled with the violet-excited probes Cascade Blue, Alexa Fluor 405, Cascade Yellow and Pacific Orange dyes. Violet-excited fluorescent microsphere mixtures with decreasing fluorescence levels were also used to detect the minimum sensitivity threshold and precision of these lasers. VLD excitation on a gel-coupled cuvette flow cytometer was used as a sensitivity baseline. RESULTS: The dual module 100 mW VLD gave both sensitivity and precision levels approaching that observed for lower-power sources on a cuvette cytometer. Single polarized VLD modules at 55 mW gave slightly decreased sensitivity for the microspheres standards and all the tested fluorochromes compared to the 100 mW source. CONCLUSIONS: While 55 mW laser sources performed adequately in the stream-in-air format, increasing the power to 100 mW did give a small but detectable increase in instrument sensitivity. This sensitivity level approached that of cuvette systems.  相似文献   

2.
BACKGROUND: Violet laser diodes have recently become commercially available. These devices emit 5-25 mW in the range of 395-415 nm, and are available in systems that incorporate the diodes with collimating optics and regulated power supplies in housing incorporating thermoelectric coolers, which are necessary to maintain stable output. Such systems now cost several thousand dollars, but are expected to drop substantially in price. Materials and Methods A 4-mW, 397-nm violet diode system was used in a laboratory-built flow cytometer to excite fluorescence of DAPI and Hoechst dyes in permeabilized and intact cells. Forward and orthogonal light scattering were also measured. RESULTS: DNA content histograms with good precision (G(0)/G(1) coefficient of variation 1.7%) were obtained with DAPI staining; precision was lower using Hoechst 33342. Hoechst 34580, with an excitation maximum nearer 400 nm, yielded the highest fluorescence intensity, but appeared to decompose after a short time in solution. Scatter signals exhibited relatively broad distributions. CONCLUSIONS: Violet laser diodes are relatively inexpensive, compact, efficient, and quiet light sources for DNA fluorescence measurement using DAPI and Hoechst dyes; they can also excite several other fluorescent probes.  相似文献   

3.
R D Bigler 《Cytometry》1987,8(5):441-444
The feasibility of installing a low power ultraviolet (UV) laser in a commercial flow cytometer was evaluated by testing an Ortho Cytofluorograf 50HH and a Coulter Epics V. Both instruments were equipped with two argon ion lasers, one emitting at 488 nm and the other in the UV region and were tested by measuring the DNA content of cells stained with Hoechst 33342 or DAPI. The coefficient of variation (CV) of the G0/G1 peak of the DNA histograms produced by each instrument did not deteriorate markedly when results obtained at 100-125 mW were compared to those obtained at 10 mW. These tests indicated that a helium-cadmium laser (He-Cd) which can produce 10 mW at 325 nm should work well as a UV laser in these instruments. An Ortho Cytofluorograf IIs was purchased with a 10 mW He-Cd laser installed in the forward position. Studies of DNA content have confirmed that this low power UV laser can produce CVs of 2.2% with DAPI stained fixed cells and 3.6% with Hoechst 33342 stained viable lymphocytes. Thus, the He-Cd laser should provide a reasonable alternative as a UV source for flow cytometers.  相似文献   

4.
Applying flow cytometric single cell analysis, we compared the performance of UV excitation from argon ion and HeCd lasers using various UV-excitable fluorochromes of cell kinetic and cell physiological relevance. The AT-specific DNA fluorochromes DAPI, Hoechst 33258, and Hoechst 33342 showed no significant differences of G1-phase resolution and cell cycle distribution. With the HeCd laser, high-resolution cell kinetic analysis applying the novel BrdU/Hoechst-PI quenching technique showed superior resolution and an almost normalized G2M/G1 channel ratio of the first cell cycle. Indo-1 analysis for detection of intracellular free calcium gave similar results for both excitation sources, although the indo-1 ratio of activated cells was lower for HeCd excitation. Monochlorobimane as an indicator fluorochrome of glutathione content could not be excited sufficiently with the 325-nm line of the HeCd laser and exhibited poor resolution between positive and negative cells. However, the second glutathione-specific fluorochrome o-phtalaldehyde gave even better results with the HeCd laser. Our data indicate that air-cooled HeCd lasers are cheap and reliable UV-excitation sources for most UV-excitable fluorochromes, and might be an alternative to the expensive water-cooled argon and krypton laser.  相似文献   

5.
In laser based flow cytometers, UV excitation of Hoechst 33258 and propidium iodide (PI) or ethidium bromide (EB) is performed with 351/364 nm high power lines of UV-capable argon ion lasers, which are expensive and short-lived. In this paper we note for the first time that helium-cadmium lasers emitting 10 to 30 mW at 325 nm are even more superior for cell kinetic bivariate bromodeoxyuridine (BrdUrd)/Hoechst PI or EB cell cycle analysis. HeCd single laser UV excitation gives comparable CVs for cell cycle distributions, and almost normal G2M/G1 ratios of 1.9 to 2.0 for all cell cycles. This is shown for synchronous and asynchronous cell populations on a FACStar+ and an Ortho Cytofluorograf. Therefore we recommend helium-cadmium lasers as low-power, cheap, and long-lived UV excitation sources for the cytochemically simple but high resolution multiparameter BrdUrd-Hoechst cell kinetic analysis.  相似文献   

6.
BACKGROUND: The aims of this study were (1) to realign cellular preparations when spots and structures are excited by different lasers of a confocal laser scanning microscope (multilaser studies); (2) to avoid the use of realigment methods by selecting fluorochromes that can be excited by only one laser (single-laser experiments). METHODS: In multilaser studies, we used propidium iodide fluorescent beads, as well as tetramethyl rhodamine isothiocyanate (TRITC), fluorescein isothiocyanate (FITC), and 4'-6 diamidino-2-phenylindole (DAPI)-stained human cancer lines. They were excited using HeNe, argon, and ultraviolet (UV) argon laser lines of a confocal laser scanning microscope. Single-laser experiments using UV excitation only were performed using europium as a model for magnetic resonance paramagnetic contrast agents. Nuclei of human cancer lines and tissue were counterstained by DAPI and cytoplasms were labeled with ELF-97 substrates. Factor analysis of medical images (FAMIS) and correlation methods were used to realign shifted images, focus images, and characterize each fluorochrome when necessary. RESULTS: In multilaser studies, superimposition of factor images corrected Z shifts and correlation methods provided X, Y correction values. In single-laser experiments, each fluorochrome was clearly distinguished in the group of fluorochromes. Estimated images in both studies showed colocalizations of structures. CONCLUSIONS: It is possible to characterize differences in the focus and alignment of fluorescent probes and to correct them. It is also possible to study colocalization of UV excitable fluorochromes (DAPI, ELF-97, europium) in cellular and tissular preparations via multilaser or single-laser experiments.  相似文献   

7.
Reliable double immunofluorescence labeling for confocal laser scanning microscopy requires good separation of the signals generated by the fluorochromes. We have successfully overcome the limitation of a single argon ion laser in achieving effective excitation of dyes with well-separated emission spectra by employing the novel sulfonated rhodamine fluorochromes designated Alexa 488 and Alexa 568. The more abundant antigen was visualized using the red-emitting Alexa 568, with amplification of the signal by a biotinylated bridging antibody and labeled streptavidin. This was combined with the green-emitting Alexa 488, which yielded brighter images than fluorescein but exhibited comparable photodegradation. With appropriate controls to ensure the absence of crosstalk between fluorescence channels, these dyes permitted unequivocal demonstration of co-localization. This combination of fluorochromes may also offer advantages for users of instruments equipped with alternative laser systems.  相似文献   

8.
Flow cytometers typically incorporate expensive lasers with high-quality (TEM00) output beam structure and very stable output power, significantly increasing system cost and power requirements. Red diode lasers minimize power consumption and cost, but limit fluorophore selection. Low-cost DPSS laser pointer modules could possibly offer increased wavelength selection but presumed emission instability has limited their use. A $160 DPSS 532 nm laser pointer module was first evaluated for noise characteristics and then used as the excitation light source in a custom-built flow cytometer for the analysis of fluorescent calibration and alignment microspheres. Eight of ten modules tested were very quiet (RMS noise < or = 0.6% between 0 and 5 MHz). With a quiet laser pointer module as the light source in a slow-flow system, fluorescence measurements from alignment microspheres produced CVs of about 3.3%. Furthermore, the use of extended transit times and < or =1 mW of laser power produced both baseline resolution of all 8 peaks in a set of Rainbow microspheres, and a detection limit of <20 phycoerythrin molecules per particle. Data collected with the transit time reduced to 25 micros (in the same instrument but at 2.4 mW laser output) demonstrated a detection limit of approximately 75 phycoerythrin molecules and CVs of about 2.7%. The performance, cost, size, and power consumption of the tested laser pointer module suggests that it may be suitable for use in conventional flow cytometry, particularly if it were coupled with cytometers that support extended transit times.  相似文献   

9.
Picosecond multiphoton scanning near-field optical microscopy.   总被引:2,自引:0,他引:2       下载免费PDF全文
We have implemented simultaneous picosecond pulsed two- and three-photon excitation of near-UV and visible absorbing fluorophores in a scanning near-field optical microscope (SNOM). The 1064-nm emission from a pulsed Nd:YVO4 laser was used to excite the visible mitochondrial specific dye MitoTracker Orange CM-H2TMRos or a Cy3-labeled antibody by two-photon excitation, and the UV absorbing DNA dyes DAPI and the bisbenzimidazole BBI-342 by three-photon excitation, in a shared aperture SNOM using uncoated fiber tips. Both organelles in human breast adenocarcinoma cells (MCF 7) and specific protein bands on polytene chromosomes of Drosophila melanogaster doubly labeled with a UV and visible dye were readily imaged without photodamage to the specimens. The fluorescence intensities showed the expected nonlinear dependence on the excitation power over the range of 5-40 mW. An analysis of the dependence of fluorescence intensity on the tip-sample displacement normal to the sample surface revealed a higher-order function for the two-photon excitation compared to the one-photon mode. In addition, the sample photobleaching patterns corresponding to one- and two-photon modes revealed a greater lateral confinement of the excitation in the two-photon case. Thus, as in optical microscopy, two-photon excitation in SNOM is confined to a smaller volume.  相似文献   

10.
BACKGROUND: Measuring CD4 T-cell counts at low cost is relevant in dealing with the human immunodeficiency virus (HIV) epidemic throughout the developing world. The recently introduced novel concepts in gating strategies and sample stabilization facilitate affordable immunophenotyping by flow cytometry. However, the impact of these developments is still limited by the high cost of currently available flow cytometers. METHODS: Diode lasers emitting 10-15 mW at 635 nm are one-tenth the size and cost and require one thousandth the power of an equivalent 488-nm argon ion laser. We used the available 635-nm diode-based flow cytometers, including PA-II, Luminex 100, SuperMot, and FACSCalibur, to investigate whether these instruments can generate reliable CD4 counts when used with allophycocyanin (APC) and cyanin-5 (Cy5)-labeled CD4 antibodies. RESULTS: We document the feasibility of obtaining leucocyte differential counts using orthogonal side scatter (SSC) without the need for forward scatter (FSC). Accurate CD4% values among lymphocytes and leucocytes can be obtained by primary CD4 gating using a single CD4 monoclonal antibody conjugated to APC or Cy5. Double immunofluorescence (IF) staining with CD4-APC (FL1) and CD45-APC-Cy7 (FL2) introduces pan-leucogating for a convenient assessment of absolute CD4 counts on double platforms. We demonstrate that small flow cytometers with laser diodes are capable of delivering absolute CD4 T-cell counts with a precision similar to the performance of the current state-of-the-art single-platform instruments (e.g., the CytoronAbsolute; R(2) = 0.961). In this respect, they appear to be superior to the nonflow CD4 counting techniques. CONCLUSIONS: Accurate CD4 counts can be generated at minimal cost on red diode laser-operated flow cytometers, retaining the potential for high throughput capacity without compromising precision. With further improvements in volumetric technology and clinical software, these cytometers may develop into a new generation of inexpensive battery-operated laboratory hardware that combines cellular phenotyping with bead-based multiplexing immunoassays for (HIV) serology.  相似文献   

11.
Amine-reactive N-hydroxysuccinimidyl esters of Alexa Fluor fluorescent dyes with principal absorption maxima at about 555 nm, 633 nm, 647 nm, 660 nm, 680 nm, 700 nm, and 750 nm were conjugated to antibodies and other selected proteins. These conjugates were compared with spectrally similar protein conjugates of the Cy3, Cy5, Cy5.5, Cy7, DY-630, DY-635, DY-680, and Atto 565 dyes. As N-hydroxysuccinimidyl ester dyes, the Alexa Fluor 555 dye was similar to the Cy3 dye, and the Alexa Fluor 647 dye was similar to the Cy5 dye with respect to absorption maxima, emission maxima, Stokes shifts, and extinction coefficients. However, both Alexa Fluor dyes were significantly more resistant to photobleaching than were their Cy dye counterparts. Absorption spectra of protein conjugates prepared from these dyes showed prominent blue-shifted shoulder peaks for conjugates of the Cy dyes but only minor shoulder peaks for conjugates of the Alexa Fluor dyes. The anomalous peaks, previously observed for protein conjugates of the Cy5 dye, are presumably due to the formation of dye aggregates. Absorption of light by the dye aggregates does not result in fluorescence, thereby diminishing the fluorescence of the conjugates. The Alexa Fluor 555 and the Alexa Fluor 647 dyes in protein conjugates exhibited significantly less of this self-quenching, and therefore the protein conjugates of Alexa Fluor dyes were significantly more fluorescent than those of the Cy dyes, especially at high degrees of labeling. The results from our flow cytometry, immunocytochemistry, and immunohistochemistry experiments demonstrate that protein-conjugated, long-wavelength Alexa Fluor dyes have advantages compared to the Cy dyes and other long-wavelength dyes in typical fluorescence-based cell labeling applications.  相似文献   

12.
In certain flow cytometry systems, it is desirable to use immersion optics to obtain optimum fluorescence yield. This is important when propidium iodide and other DNA fluorochromes are used that have weaker fluorescence emission compared to DAPI, when a lamp is used instead of a laser and when the DNA concentrations are low. Our Partec PA II with a horizontally oriented objective and a vertically oriented flow chamber precludes using a liquid immersion medium. The problem was solved using an optical gel with appropriate characteristics. This gel is commercially available and commonly used for connecting glass fiber cables, but has never been used for microscopy before. Compared to the manufacturer's objective (40 ×, aperture 0.8), the fluorescence yield was improved approximately four-fold using the optical gel and a 40 × glycerol objective (aperture 1.25). This innovation widens the applicability of flow cytometers with horizontally oriented objectives and vertical flow chambers. We expect it to facilitate the use of propidium iodide as a DNA stain, especially when interspecific genome size comparisons are to be done and base ratio dependent bias must be avoided.  相似文献   

13.
C L Davies  M Kovacs 《Cytometry》1990,11(4):533-538
In a multiparameter flow cytometric study, the fluorescence from the two different dyes fluorescein and dansyl-lysine were detected in the same spectral interval on the same photomultiplier tube, using two lasers to excite the fluorochromes at two separate laser foci. The two signals were split by a T-cable at the output of the photomultiplier tube and synchronized by delaying the first signal. Dansyl-lysine binds to the membrane of heat-inactivated cells and was used to distinguish between live and dead cells after a hyperthermic treatment. By gating on the dansyl-lysine signal, the DNA distribution and surface antigen expression of live and dead cells were obtained separately, using Hoechst 33342 and a monoclonal antibody conjugated to fluorescein.  相似文献   

14.
Continuous wave two-photon scanning near-field optical microscopy.   总被引:1,自引:0,他引:1       下载免费PDF全文
We have implemented continuous-wave two-photon excitation of near-UV absorbing fluorophores in a scanning near-field optical microscope (SNOM). The 647-nm emission of an Ar-Kr mixed gas laser was used to excite the UV-absorbing DNA dyes DAPI, the bisbenzimidazole Hoechst 33342, and ethidium bromide in a shared aperture SNOM with uncoated fiber tips. Polytene chromosomes of Drosophila melanogaster and the nuclei of 3T3 Balb/c cells labeled with these dyes were readily imaged. The fluorescence intensity showed the expected nonlinear (second order) dependence on the excitation power in the range of 8-180 mW. We measured the fluorescence intensity as a function of the tip-sample displacement in the direction normal to the sample surface in the single- and two-photon excitation modes (SPE, TPE). The fluorescence intensity decayed faster in TPE than in SPE.  相似文献   

15.
Antibodies against cell surface antigens may be internalized through their specific interactions with these proteins and in some cases may induce or perturb antigen internalization. The anti-cancer efficacy of antibody-drug conjugates is thought to rely on their uptake by cancer cells expressing the surface antigen. Numerous techniques, including microscopy and flow cytometry, have been used to identify antibodies with desired cellular uptake rates. To enable quantitative measurements of internalization of labeled antibodies, an assay based on internalized and quenched fluorescence was developed. For this approach, we generated novel anti-Alexa Fluor monoclonal antibodies (mAbs) that effectively and specifically quench cell surface–bound Alexa Fluor 488 or Alexa Fluor 594 fluorescence. Utilizing Alexa Fluor–labeled mAbs against the EphA2 receptor tyrosine kinase, we showed that the anti-Alexa Fluor reagents could be used to monitor internalization quantitatively over time. The anti-Alexa Fluor mAbs were also validated in a proof of concept dual-label internalization assay with simultaneous exposure of cells to two different mAbs. Importantly, the unique anti-Alexa Fluor mAbs described here may also enable other single- and dual-label experiments, including label detection and signal enhancement in macromolecules, trafficking of proteins and microorganisms, and cell migration and morphology.  相似文献   

16.
Flow cytometry has been widely used to obtain information about DNA content in a population of cells, to infer relative percentages in different cell cycle phases. This technique has been successfully extended to the mitotic tissues of the model organism Drosophila melanogaster for genetic studies of cell cycle regulation in vivo. When coupled with cell-type specific fluorescent protein expression and genetic manipulations, one can obtain detailed information about effects on cell number, cell size and cell cycle phasing in vivo. However this live-cell method has relied on the use of the cell permeable Hoechst 33342 DNA-intercalating dye, limiting users to flow cytometers equipped with a UV laser. We have modified this protocol to use a newer live-cell DNA dye, Vybrant DyeCycle Violet, compatible with the more common violet 405nm laser. The protocol presented here allows for efficient cell cycle analysis coupled with cell type, relative cell size and cell number information, in a variety of Drosophila tissues. This protocol extends the useful cell cycle analysis technique for live Drosophila tissues to a small benchtop analyzer, the Attune Acoustic Focusing Cytometer, which can be run and maintained on a single-lab scale.  相似文献   

17.
Current and future applications of flow cytometry in aquatic microbiology   总被引:26,自引:0,他引:26  
Flow cytometry has become a valuable tool in aquatic and environmental microbiology that combines direct and rapid assays to determine numbers, cell size distribution and additional biochemical and physiological characteristics of individual cells, revealing the heterogeneity present in a population or community. Flow cytometry exhibits three unique technical properties of high potential to study the microbiology of aquatic systems: (i) its tremendous velocity to obtain and process data; (ii) the sorting capacity of some cytometers, which allows the transfer of specific populations or even single cells to a determined location, thus allowing further physical, chemical, biological or molecular analysis; and (iii) high-speed multiparametric data acquisition and multivariate data analysis. Flow cytometry is now commonly used in aquatic microbiology, although the application of cell sorting to microbial ecology and quantification of heterotrophic nanoflagellates and viruses is still under development. The recent development of laser scanning cytometry also provides a new way to further analyse sorted cells or cells recovered on filter membranes or slides. The main infrastructure limitations of flow cytometry are: cost, need for skilled and well-trained operators, and adequate refrigeration systems for high-powered lasers and cell sorters. The selection and obtaining of the optimal fluorochromes, control microorganisms and validations for a specific application may sometimes be difficult to accomplish.  相似文献   

18.
We describe a procedure for simplified, simultaneous one-step staining in 10 min for DNA and cell and tissue proteins using a newly developed staining solution containing 0.03% hematoporphyrin (HP) with 0.001% DAPI [or with Hoeschst 33342 (HO)]. These HP/DAPI or HP/HO solutions were especially developed to facilitate a trial of automated cancer cell screening on sputum samples using flow cytometry. Under UV light (365 nm) with fluorescence microscopy, HP/DAPI-stained cells showed red fluorescence (max. 670 nm) of cytoplasm and simultaneous blue fluorescence (max. 470 nm) of nuclei. The distance between the maximum peak of fluorescence spectra of DNA and that of protein was as large as 200 nm, and there was no detectable overlapping of each spectrum at the photometric filter range, which provided accurate measurement of DNA and protein. On flow cytometry, a single UV beam (370 nm) from the argon laser was used for excitation of both dyes. Measurement of DNA was done using a 470-nm bandpass filter and of protein using a 640-nm longpass (or 670-nm bandpass) filter. Reflecting the undetectable overlapping of the fluorescence spectra of protein and DNA, normal diploid cells in sputum revealed horizontal distributions along the 2C level on the dot-plot display of flow cytometry, which made sorting of abnormal hyperdiploid cells and cancer cells easier.  相似文献   

19.
Telford W  Cox W  Singer V 《Cytometry》2001,43(2):117-125
BACKGROUND: The fluorogenic alkaline phosphatase (AP) substrate 2-(5'-chloro-2'-phosphoryloxyphenyl)-6-chloro-4-(3H)-quinazolinone (ELF(R)-97 phosphate, for Enzyme-Labeled Fluorescence) has been used primarily in microscope-based imaging applications to detect endogenous AP activity, antigens and various ligands in cells and tissues, and nucleic acid hybridization. In a previous study, we demonstrated the applicability of ELF-97 phosphate for detecting endogenous AP activity by flow cytometry. In this study, we show that the spectral characteristics and high signal-to-noise ratio provided by the ELF-97 phosphate make it a useful label for immunodetection via flow cytometry. It can be combined with a variety of other fluorochromes for multiparametric flow cytometry analysis of both endogenous AP activity and intracellular and extracellular immunolabeling with AP-conjugated antibodies. METHODS: ELF-97 phosphate detection of endogenous AP activity in UMR-106 rat osteosarcoma cells was combined with intracellular antigen detection using Oregon Green 488 dye-conjugated secondary antibodies and DNA content analysis using propidium iodide (PI) or 7-aminoactinomycin D (7-AAD). ELF-97 phosphate detection of endogenous AP was also tested for spectral compatibility with a variety of other commonly used fluorochromes. ELF-97 phosphate was then used to directly label intracellular antigens via AP-conjugated antibodies, again combined with the analysis of DNA content using PI and 7-AAD. ELF-97 phosphate was also used to directly detect extracellular antigens. It was combined with Oregon Green 488 dye, phycoerythrin (PE), and PE-Cy5 dye-labeled antibodies for simultaneous four-color analysis. All samples were analyzed on a dual-beam flow cytometer, with UV excitation of the ELF-97 alcohol reaction product. RESULTS: Application of the ELF-97 phosphate to detect AP was found to be compatible with immunodetection and DNA staining techniques. It was also spectrally compatible with a variety of other fluorochromes. Endogenous AP activity could be detected simultaneously with both intracellular antigens labeled using Oregon Green 488 dye, PE, Cy5 dye and Alexa Fluor 568 dye-conjugated antibodies, and DNA content analysis with PI or 7-AAD. This multiparametric assay accurately delineated the distribution of AP in cycling cells and was able to identify cell subsets with varying endogenous AP levels. The ELF-97 alcohol reaction product was found to be an effective label for intracellular antigen immunolabeling with AP-conjugated reagents, and could also be combined with PI and 7-AAD. ELF-97 phosphate was also found to be a useful label for extracellular antigen immunolabeling with AP conjugates, and was compatible with Oregon Green 488 dye, PE, and PE-Cy5 dye-labeled antibodies for four-color surface labeling with minimal spectral overlap and color compensation. CONCLUSIONS: ELF-97 phosphate was shown to be a useful label for both endogenous and antibody-conjugated AP activity as detected by flow cytometry. Its spectral characteristics allow it to be combined with a variety of fluorochromes for multiparametric analysis. Cytometry 43:117-125, 2001. Published 2001 Wiley-Liss, Inc.  相似文献   

20.
A fluorescent resonance energy transfer (FRET)-based hybridization assay for detecting multiplex ligation-dependent probe amplification (MLPA) products has been developed, extending the diagnostic power of the technique and demonstrating the possibility of combining MLPA with microarrays for the detection of multiple mutations. FRET is one of the most commonly used detection techniques for hybridization assays. To investigate the applicability of FRET based detection of MLPA products, a sandwich assay was designed to detect gene copy number by exploiting an immobilized probe labeled with an acceptor dye, Alexa Fluor 555, which hybridises to specific PCR amplicons, followed by hybridization of a second probe labeled with the donor dye, Alexa Fluor 488. Following excitation of the Alexa Fluor 488, a FRET signal was produced only if a DNA sequence specific to the BRCA1 exon 13 was present in the test sample. We have verified this assay on a DNA sample of a patient carrying a heterozygous BRCA1 exon 13 deletion using male genomic DNA as control. Here we demonstrate that the DNA sample containing the heterozygous deletion generated a considerably reduced FRET signal as compared to the control male human DNA. Our results show that the FRET design presented in this study can differentiate between reduced copy numbers any genomic DNA sequence after MLPA analysis, and the reported format is applicable to multiplex detection of MLPA products, using microarrays, or optical biosensor arrays, and future work will focus on the demonstration of this.  相似文献   